Section 1207. Stairs, Exits, and Section 1207. Stairs, Exits, and Occupant Loads Occupant Loads
Section 1207. Stairs, Exits, and Section 1207. Stairs, Exits, and Occupant Loads Occupant Loads
National Building Code (PD Fire Code (R.A. No. 9514) BP 344 Local Ordinances
1096)
1. Egress (Exit) Section 1207. Stairs, Exits, and SECTION 10.2.5.2 4. LOCATION OF Central Business
Occupant Loads
EMERGENCY EXIT District Zone
A. Permissible Exit
a. Exi
Exits
Components An exit 4.1 Wall mounted or free (C-4, composed of
1. Number of Exits
shall consist of the standing tablets with an subzones C-4A, C-4B, C-
Above 1st storey – 10
approved components embossed plan conguration 4C, C-4D, C-4E, C-4F, C-
occupant – 2 exits
that are described, of the building which also 4G, C-4H, C-4I, C-4J, and
Mezzanine – 185 sq.m
regulated, and limited as shows the location of the C-4K). This central
area or more than
to use by Sections lobby, washrooms and business district zone
18m in dimension – 2
10.2.5.3 through emergency exits of the shall be used primarily
exits
500-999 – 3 exits 10.2.5.12 of this IRR. building (indicated by for high density oce
Exit components shall be dierent textures with and residential
2. Exits – if only 2 exits
constructed as an corresponding meanings) developments on a
required , shall be
integral part of the should be provided either in metropolitan scale of
placed distance apart
building or shall be front of the building or at the operations, with
not < 1/5 of the
permanently axed main lobby.
lobby. The markings of miscellaneous support
perimeter area.
thereto. this tablet should be uses.
3. Distance of Exits –
readable by both the fully
w/o sprinkler – 45m
D. Occupant Load sighted and the blind The total Gross Floor
from exterior exit 1. The total capacity of persons. Area occupied by the
door, w/ sprinkler
means of egress for any additional accessory
60m
oor, balcony, tier, or 4.2 Flashing light directional uses are as follows:
4. Doors
other occupied space signs indicating the i. In C-4A and C-4Blots
a. Swing
Swing – exit
exit door
door
shall be sucient for the location(s) of re exit shall with frontage along
shall swing to exit
occupant load thereof. be provided at every change Ayala Avenue/Paseo de
travel in
The occupant load in any in direction with sucient Roxas/Makati Avenue,
hazardous areas
building or portion power provided in the total FAR shall not
w/ 50 or more thereof shall be the accordance with the exceedFAR 1, exclusive
exceedFAR
occupant load maximum number of provisions for emergency of the Gross Floor Area
b. Double
Double act
acting
ing persons that may be in lighting under Section 3.410 occupied by restaurants,
doors – view panel the space at any time, of P.D. NO. 1185 (The Fire canteens, and food-
of not < 1,300 as determined by the Code of the Philippines) serving establishments
sq. cm. City/Municipal Fire located at and/or above
c. Width
Width and
and HHeig
eight
ht – Marshal having the second oor of a
not < 900mm in jurisdiction, but shall not building.
width, not < be less than the number
2.00m in height, computed by dividing
opening – 90 the oor area assigned
degrees and exit to that use by the
way clear width occupant load factor in
not < 700mm accordance with the
5. Door Leaf Width – requirements of
max of 1.20 Divisions 8 through 17 of
6. Corridors and Exterior this Chapter for
Exit Balconies individual occupancies
a. Widt
Widthh – not <
1.10m See Table 1.2
b. 6.00m
Dead
Dead Ends
En dslength
in – max Minimum Corridor
7. Stairways Width
a. Width
Width – se
servi
rving
ng an
occupant load of The minimum width of
more than 50 any corridor or
shall not be < passageway serving as a
1.10m, occupant required exit or means of
load of 50 or travel to or from
e. Lan
Landin
run dings
gs – of
– max straig
straight
ht
1.20m, vertical Travel Distance to
f. Dist
Distan
ance
ce be
bett Exits
landings – max of
3.60m vertical 1. Exits shall be as
distance landings. remote from other as
g. Handra ils – not <
Handrails practicable, so arranged
800mm nor more that it will not be
paths of travel
dierent in
directions.
G. Number of Means of
Egress
1. The number of means
of egress from any
balcony, mezzanine,
storey, or portion thereof
1. Setbac
Setbacks
ks – vacant
vacant space SECTION 36. Yard and
3. Setback bet the bldg. & lot lines not Building
lines. Thethus
footprint building
dened
should rise to a minimum
height of fteen (15)
meters. However,
indentations may be
permissible on the
ground oor for the
purpose of making
However, in Block 4,
(LRC) Psd-6132 and Plan
(LRC) Pcs-1332 along
Paseo de Roxas and
Makati Avenue, the
building may be set back
from any boundary of
the lot, provided that a
minimum setback of two
(2) meters from the
common
adjoining boundaries with
properties is
observed. The setback
shall be measured from
the property line to the
nearest projection of the
building.
5. Floor Area Maximum Floor Area
1. Allo
Allowabl
wable
e Maximu
Maximum
m Ratio:
1. Genera
General.l. The
Allowable
Maximum Total
Gross Floor Area
(TGFA) of any
proposed building
shall only be as
allowed under this
Rule
2. TGFA
TGFA LiLimitati
mitation
on “
In Table Vii.6.1. the
percentages
indicated in the 3rd
through 8th
columns are the
percentages of the
T
Total
otal Lot Area
(TLA) that may be
used to determine
the Allowable
Maximum TGFA
while the
multiplier numbers
3, 5, 12, 18 and 30
represent the
number of
storeys.
3. The All
Allowa
owable
ble
Maximum
TGFA should not
TGFA
exceed the
Allowable
Maximum Volume
of Building
(AMVB). If
exceeded, the
Allowable
Maximum TGFA
must be adjusted
since the AMVB
must always
prevail.
1. Genera
General.l. The SECTION 11. General
maximum height Provisions. The allowable
and number of land uses and maximum
storeys of building densities/heights
proposed building in the zones and subzones
shall be dependent dened in this Ordinance
upon the character are enumerated in the
of use or succeeding Sections.
occupancy, on the 1. Allowable land uses are
type of
construction, on specied according to
Principal Uses and
end-user Accessory Uses. Principal
population density, Uses dene the dominant
light and use of a zone/lot while
ventilation, width Accessory Uses support the
of road right-of- Principal Uses allowed in a
way, building bulk, zone/lot.
o-street cum o-
site parking
requirements and In
3),Residential
Commercial (R-1, R-2,
(C-1, R-
C-2,
local land use plan
C-3), Central Business
and zoning
District (C-4A, C-4B, C-4C,
regulations.
C-4D, C-4E, C-4F, C-4G, C-
4H, C-4I, C-4J, and C-4K),
2. The Buildi
Building
ng
PUD, SMU, SPUR, DRIVE,
Height Limit (BHL)
HPZ, GCZ,INS, and Sports
shall only be as
Club Recreational (REC-3)
allowed under this