SmartLink™ Software
GR™-12/15/20
GRC™-12
QS™-12/15/20
GS™-30/32/46/47
GS™-46AV
GS™-69 DC
GS™-69 Bi-Energy
X-12
X-14
Part No. 216767GT
Rev E
August 2018
Instructions Rev E
Introduction
Introduction
Introduction
Tools Required:
Tools Required
Introduction
If you have any further questions regarding these Theory of Operation
instructions or need assistance, please contact
Genie Product Support at one of the following SmartLink software consists of two parts, the
telephone numbers: application software (also called firmware) and the
bootloader software. The only time an operator will
United States: + 800 536 1800 enter bootloader mode is when updating the
Canada: + 425 881 1800 software.
Europe: UK + 44 1476 584 333 Software can only be updated from bootloader
France + 33 237 260 986 mode (i.e. when the bootloader software is running
Germany + 49 4221 491 810 instead of the application software). Bootloader
mode can be started from the web service tool if
Iberica + 34 935 725 090 the machine is functioning properly. The machine
Italy + 39 075 941 8132 will always start in application mode.
Scandinavia + 46 3157 5154 Bootloader mode can be started manually if the
Other locations + 31 165 51 93 22 machine is not functioning properly.
Middle East: + 97 143 391 800 or Once in bootloader mode it is possible to update
+ 97 150 459 7937 either the application software or the bootloader
Australia: + 61 7 3456 4444 software. Genie periodically release firmware
Brazil + 0 800 031 0100 updates (i.e. new application software), and on rare
occasions releases new bootloader software.
South America - other + 56 9 6431 2110
locations
All other locations + 1 425-881 1800
Procedure
Procedure
Checking the Application 2 Press the ground control scroll down button.
Revision from the Ground Result: The GCON LCD will show the software
revision and hour meter information. After 5
Controls seconds, the ground controls LCD will return
1 Turn the key switch to ground controls or to machine model and hour meter information.
platform controls and pull out the red
Emergency Stop button to the on position at
both ground and platform controls. SOFTWARE REV
Result: The PCON LCD will show "CH". 00000.0 Hours
=+ -
=+ -
2
1
1 2 3 4
Procedure
Checking the Application 5 Read and record the IP address.
Revision Using the Web Service Note: The display wil only show the IP
Tool address for 3 seconds. Press the scroll
up button to display the IP address for
1 Open the GCON compartment. another 3 seconds.
Note: Some models will require opening the ground
control box to access the GCON. 6 Launch a web browser such as Internet
Explorer ®, Chrome ® or Firefox ® on your PC
2 Turn the key switch to ground controls or or laptop. Type the IP address from step 5 into
platform controls and pull out the red the web browser address bar and press enter.
Emergency Stop button to the on position at
both ground and platform controls. Result: The following screen will be displayed.
3 Locate the diagnostic port on the side of the
GCON. Remove one of the fasteners securing
the cover and set aside. Loosen the other
fastener. Do not remove it.
1 diagnostic port
Procedure
Checking the Application 5 Locate the diagnostic port on the side of the
GCON. Remove one of the fasteners securing
Revision and Bootloader Date the cover and set aside. Loosen the other
from Bootloader Mode fastener. Do not remove it.
3 1 diagnostic port
1 2 3 4
Result: The ground controls LCD display will 8 Launch a web browser such as Internet
show the following: Explorer ®, Chrome ® or Firefox ® on your PC
or laptop. Type the IP address from step 7 into
the web browser address bar and press enter.
SOFTWARE UPDATE
Result: The following screen will be displayed.
CONNECT ETHERNET
Procedure
Loading or Updating Machine Entering Bootloader Mode from
Software Machine Application Mode
Note: Before updating the machine software, open 1 Open the GCON compartment.
a web browser and navigate to the following
Note: Some models will require opening the ground
location for the Genie Machine Software Download
control box to access the GCON.
portal, http://firmware.genielift.com. Perform a
search by applying the appropriate filters and 2 Turn the key switch to ground controls or
download the machine software. Download the platform controls and pull out the red
appropriate firmware files for your machine and Emergency Stop button to the on position at
unzip them. both ground and platform controls.
To update the software, the machine will need to 3 Locate the diagnostic port on the side of the
be placed in bootloader mode. Enter Bootloader GCON. Remove one of the fasteners securing
Mode from Machine Application Mode or Manually the cover and set aside. Loosen the other
Enter Bootloader Mode. fastener. Do not remove it.
If the machine is functioning normally, software can
be updated by logging into the Machine Service
Tool. Refer to Entering Bootloader Mode from
Machine Application Mode.
If the machine is not functioning or problems are
encountered while using the Machine Service Tool,
the bootloader can be started manually. Refer to
Entering bootloader Mode Manually.
1 diagnostic port
Procedure
5 Read and record the IP address. 8 Select the Software tab at the header bar.
Note: The display wil only show the IP Result: The following screen will be displayed.
address for 3 seconds. Press the scroll
up button to display the IP address for
another 3 seconds.
Procedure
Entering Bootloader Mode 5 Locate the diagnostic port on the side of the
GCON. Remove one of the fasteners securing
Manually the cover and set aside. Loosen the other
1 Open the GCON compartment. fastener. Do not remove it.
1 1
3
1 2 3 4
1 diagnostic port
2
6 Connect one end of a CAT5 Ethernet cable
into the diagnostic port. Connect the other end
into a PC or laptop.
137562 Result: The ground controls LCD display will
show the following:
1 LCD display
2 enter button
3 escape button OPEN WEB BROWSER
Procedure
Software Installation 3 Select the Reprogram Device(s) button to
start the ECM software update.
Note: The following screen will be displayed after
entering bootloader mode. If application software has been installed:
Result: The following screen will be displayed
after the software update is complete.
Note: Do not turn off power while the ECM is being
reprogrammed.
Note: After the software update is complete, select
Run Application to exit software update mode.
Procedure
4 Push in the red Emergency Stop button and
disconnect the CAT5 cable from the GCON.
5 Secure the diagnostic port cover using the
retaining fasteners removed in step 5. Do not
over tighten.
Note: Machines equipped with AGM batteries will
need to select the AGM battery type using the
GCON set parameters screen. Refer to the
Machine Setup procedure in the Service and
Repair manual that is appropriate for your machine.
Note: GS-69 DC and GS-69 Bi-Energy models are
not equipped with AGM batteries.