Download as pdf or txt
Download as pdf or txt
You are on page 1of 47

Product Submittal

FOSROC® Proofex OGP


ABOUT
FOSROC INTERNATIONAL
Since the company’s beginning over 80 years ago, Fosroc has developed into an International
leader in delivering Constructive Solutions for projects across a broad range of market
segments including transport, utilities, industrial and general buildings.

Fosroc’s commitment to customer service and technical support is second to none. We work
closely with architects, structural engineers, contractors and owners to best understand their
requirements. Together, we can develop a bespoke solution for a construction project, adding
value and becoming more than just a materials supplier, but a solution provider.

Fosroc has extensive network of offices and manufacturing locations across Europe, the
Middle East, India, North, South and East Asia, and is further represented in other regions
across the world by distributor and licensee partners.

Selecting from the full portfolio of Fosroc products and services and integrating expert
technical support, world class customer service and innovation, Fosroc goes beyond just
product selling to ensure that we partner with our customers to deliver complete
constructive solutions.

> Admixtures
> Adhesives
> Protective Coatings
> Concrete Repair
> Industrial Flooring

> Grouts & Anchors


> Joint Sealants
> Surface Treatments
> Grinding Aids
> Waterproofing

Leader in delivering
Constructive Solutions

Worldwide!
FOSROC DELIVER SOLUTIONS
NOT JUST PRODUCTS
Contents
Technical Datasheet
Safety Datasheets
Method Statement
Test Reports
Technical Datasheets
Fosroc® Proofex OGP
Loose laid synthetic TPO waterproofing
membrane

Uses Specification
Provides a continuously loose laid waterproof The waterproofing shall be a reinforced 1.2mm/1.5mm thick
membrane system for building and civil engineering loose laid TPO/FPA membrane with hot air welded seams.
structures and is particularly suited to above ground
applications including green roofs and cool roofs
Typical properties
■ Podium, garden roofs, flat/sloping roofs and green roofs,
Thickness (EN 1849-2) 1.2mm and 1.5mm
below-ground waterproofings
■ Below ground waterproofing Standard Colour Upper Layer : Grey

■ Lining of ponds, lakes, canals, reservoirs and landfills Underside : Black

Weight per unit area 1.2mm : 1.09


Advantages (EN1849-2) (kg/m2 ) 1.5mm : 1.45
■ Environment friendly; Zero VOC’s, no plasticisers, non-
Tensile Strength (ASTM D412 and EN12311-2)
toxic, 8% of recycled material
■ Fast application Longitudinal 1.2mm : 17N/mm2

■ High resistance to weathering and UV 1.5mm : 17N/mm2


Transverse 1.2mm : 16N/mm2
■ Resistance to root penetration
1.5mm : 16N/mm2
■ Welded joints for maximum watertightness
Elongation at break (ASTM D412 and EN12311-2)
■ No separation layer required against EPS
Longitudinal >700%
■ Approved for use in contact with potable water
Transverse >700%
■ Excellent long term performance
Water impermeability Pass test
Water vapour transmission
Standard compliance (ASTM96) Nil
Independently certified performance, BBA certificate number Tear resistance (EN12310-1)
15/5242.
Longitudinal 1.2mm : 500N
1.5mm : 600N
Description
Transverse 1.2mm : 470N
TPO/FPA (Thermoplastic Polyolefin Flexible Polypropylene
Alloy) membrane produced by extrusion of granules 1.5mm : 600N
resulting from the incorporation of ethylene propylene rubber
Root resistance (FLL) Pass test– no penetration
into a polypropylene matrix together with other additives as
appropriate to the type of membrane. Lap joint strength Pass test-broken out joint
(EN12317 and UEATc)
The membrane is manufactured in two different colours, it is
coloured grey on top and black on the underside. This helps Durability Resistance UV Pass test 2500hrs– no crack
(EN1297)
to identify any damages that may occur during application.
Hail resistance 29m/s
(EN13583)
Resistance to Micro– Pass test-Level 2
organism (EN846)
Fire resistance EN 13501-1 Class E

Suitable for use in Pass test


contact with potable
032-032-2325 water (BS6920
Environmentally
Preferred Coating

Page 1
Fosroc® Proofex OGP

Instruction for use Precautions

Surface preparation Health and Safety


Surfaces should be free from cavities and projecting nibs. All There are no health hazards associated with the use of
surfaces shall be free from running water. Refer to the Fosroc Proofex OGP. For information associated with Fosroc
method statement for further details. Proofex OGP Adhesive please consult the relevant MSDS.

Application Fire
The membrane layers are overlapped to achieve a minimum Fosroc Proofex OGP is non flammable.
weld of 50mm. Hot air welding can be either hand applied or Fosroc Proofex OGP Adhesive is highly flammable.
by means of automatic machines.
For corner detailing use Fosroc Proofex OGP
Internal/External corner pieces. Supply

For upstand terminations use Fosroc Proofex Metal Strip. Proofex OGP : 2.1mm wide x 25m
(1.2mm and 1.5mm) long rolls
For vertical detailing use Fosroc Proofex OGP adhesive.
(other thicknesses available upon special request)
Various Fosroc Proofex TPO drain outlets and connectors Proofex OGP Adhesive : 20kg pail
and aerator are available (Coverage rates approx 0.4-
0.6kg/m2)
For additional details on installation including relevant fixings
and washers and a list of Fosroc approved applicators refer Proofex Metal Strip : 1m x 2m sheets
to your local Fosroc office. 1.2mm thick 1m x 3m sheets
Proofex OGP : Each
Corner pieces
Storage Drain connectors
Fosroc Proofex OGP must be stored in a cool, dry store in Drain outlets
the original unopened packaging. Aerator

Store rolls horizontally, not more than one pallet high.

Important note
Fosroc products are guaranteed against defective materials and manufacture and are sold subject to its standard Conditions for the
Supply of Goods and Services, copies of which may be obtained on request. Whilst Fosroc endeavours to ensure that any advice,
recommendation, specification of information it may give is accurate and correct, it cannot, because it has no direct or continuous
control over where or how its products are applied, accept any liability either directly or indirectly arising from the use of its
products, whether or not in accordance with any advice, specification, recommendation of information given by it.

Fosroc International
Malaysia China Indonesia Singapore
Fosroc Sdn. Bhd Fosroc Guangzhou Limited PT. Fosroc Indonesia Fosroc Singapore
Tel : +60 3 5102 5660 Tel : +86 20 8226 9245 Tel : +62 21 897 2103 Tel: +65 6665 3828
enquirymalaysia@fosroc.com enquiryhongkong@fosroc.com enquiry.indonesia@fosroc.com enquirysingapore@fosroc.com

Thailand Hong Kong Vietnam Rest of Southeast Asia


Fosroc Thailand Fosroc Hong Kong Fosroc Vietnam Fosroc Construction Chemicals Pte Ltd
Tel : +66 2 136 9898 Tel : +852 2 882 8662 Tel : +82 222 3765 971 Tel : +65 6665 3828
enquirythailand@fosroc.com enquiryhongkong@fosroc.com enquiryvietnam@fosroc.com enquiry.FGTAsia@fosroc.com

www.fosroc.com
Page 2 Ref: ProofOGP/DS/09/20
Safety Datasheets
SAFETY DATA SHEET
1: IDENTIFICATION OF THE SUBSTANCE/PREPARATION OF THE
COMPANY/UNDERTAKING
Product Name: Proofex OGP
Application: Synthetic waterproofing membrane.
Company: Al Gurg Fosroc LLC
Address: P O Box 657, Dubai, United Arab Emirates
Telephone: +971 4 2039699 Fax: +971 4 2859649

2: COMPOSITION/INFORMATION ON INGREDIENTS

Composition: Polypropylene Resins

All constituents of this product are in EINECS (European Inventory of Existing Commercial Chemical Substances) or
ELINCS (European list of New Chemical Substances) or are exempt.

3: HAZARDS IDENTIFICATION
Non- hazardous

4: FIRST AID MEASURES


In standard use condition there are no dangers related to this product.
In case where material in the molten state comes in contact with the skin, the latter should be flushed for a
sustained period with cold water. Avoid using solvents to remove the material. Remove any contaminated clothing if
this is not stuck to the skin and consult a physician.
In case where the molten material comes in contact with eyes, the latter must be rinsed immediately with plenty of
cold water for at least 15 minutes. Seek medical attention if particles stick inside the eyes.
In cases of swallowing, seek immediate medical attention.

5: FIRE FIGHTING MEASURES


Suitable Extinguishing Media: Carbon dioxide, Powder or form.
Special Protective Equipment: Self-contained breathing apparatus.

6: ACCIDENTAL RELEASE MEASURES


Personal Precautions: Wear suitable protective clothing, gloves and eye/face protection.
Environmental Precautions: Prevent entry into drains, sewers and watercourses.
Decontamination Procedures: Solid product: Gather into containers. Dispose of as waste.

Issue No: 01 Date: 21.04.2009 Product Name: PROOFEX OGP Page 1 of 4


7: HANDLING AND STORAGE
Handling: Do not Subject to direct heat.
Where manual lifting is unavoidable use correct kinetic lifting techniques.
Storage: Store in cool, dry area. Protect from sun, frost, heat sources and electricity

8: EXPOSURE CONTROLS/PERSONAL PROTECTION


Occupational Exposure Limits: None assigned
Engineering Control Measures: No specific ventilation requirement noted.
Personal Protective Equipment: Wear impervious gloves (e.g. of PVC), in case of repeated or prolonged contact.

9: PHYSICAL AND CHEMICAL PROPERTIES


Physical State: Solid Sheet Material.
Odour: Odourless
Density: 890 – 910 kg/m3
pH (concentrate): Not applicable (non-aqueous)
Flash Point (closed, 20oC): None.
Explosive Properties (%): None
Oxidising Properties: None
Solubility: soluble in chlorinated solvents

10: STABILITY AND REACTIVITY


Stability: Stable to normal conditions of storage
Materials to Avoid: Sources of heat, direct sunlight and electricity

11: TOXICOLOGICAL INFORMATION


The product is not chemically reactive and is been considered biologically inert.

12: ECOLOGICAL INFORMATION


Environmental Assessment: When used and disposed of as intended, no adverse environmental effects
are foreseen.
Persistence and Degradability: Not readily biodegradable.
Bioaccumulative Potential: Not expected to be bioaccumulative.
Ecotoxicity: Not expected to be ecotoxic to fish/daphnia/algae.

Issue No: 01 Date: 21.04.2009 Product Name: PROOFEX OGP Page 2 of 4


13: DISPOSAL CONSIDERATIONS
Disposal must be in accordance with local and national legislation.
Unused Product: Dispose of an approved manner.
Used/Contaminated Product: As for Unused Product.
Packaging: The method of disposal must be acceptable to the local authority.

14: TRANSPORT INFORMATION


This product is NOT classified as dangerous for transport. No hazards are associated with this product.

15: REGULATORY INFORMATION


This product is NOT classified as dangerous for supply

Codes of Practice: Waste Management. The Duty of Care.


Guidance Notes:
The above publications are available from HMSO.

16: OTHER INFORMATION


The data and advice given apply when the product is used for the stated application or applications. The product is not sold as
suitable for any other application. Use of the product for applications other than as stated in this sheet may give rise to risks not
mentioned in this sheet. The product should not be used other than for the stated application or applications without seeking
advice from Al Gurg Fosroc.
If this product has been purchased for supply to a third party for use at work, it is the purchaser's duty to take all necessary steps to
secure that any person handling or using the product is provided with the information in this sheet.
It is the responsibility and duty of the employer to inform employees and others who may be affected of any hazards described in
this sheet and of any precautions which should be taken.
This sheet does not constitute or substitute for the users own assessment of workplace risk, as required by other health and safety
legislation.
Further copies of this Safety Data Sheet may be obtained from Al Gurg Fosroc LLC.

Date Printed: SDS Reference:

Issue No: 01 Date: 21.04.2009 Product Name: PROOFEX OGP Page 3 of 4


constructive solutions
SAFETY DATA SHEET
1: IDENTIFICATION OF THE SUBSTANCE / PREPARATION AND OF THE
COMPANY / UNDERTAKING
Product Name: PROOFEX OGP ADHESIVE

Application: Application of the substance / the preparation adhesives

Company: Fosroc Limited

Address: Drayton Manor Business Park


Coleshil
Tamworth
Staffordshire
B77 2JU

Telephone: +44 (0) 1827 262222

Fax : +44 (0) 1827 262444

Email: uk@fosroc.com

2: HAZARDS IDENTIFICATION

Hazard description:

Xi Irritant
F Highly flammable
N Dangerous for the environment

Information concerning particular hazards for human and environment:


The product has to be labelled due to the calculation procedure of the "General Classification guideline for preparations of the
EU" in the latest valid version.
Has a narcotizing effect.
R 11 Highly flammable.
R 38Irritating to skin.
R 51/53 Toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment.
R 67 Vapours may cause drowsiness and dizziness.· Classification system:
Classification system:
The classification is according to the latest editions of the EU-lists, and extended by company and literature data·

GHS label elements

Danger

DangerH225 - Highly flammable liquid and vapour.

Warning

H315 - Causes skin irritation.


H319 - Causes serious eye irritation.
H317 - May cause an allergic skin reaction.
H336 - May cause drowsiness or dizziness.

H411 - Toxic to aquatic life with long lasting effects.

Contains zinc bis(dibutyldithiocarbamate). May produce an allergic reaction.

Issue No: 01 Date: 01/04/2011 Proofex OGP Adhesive Page: 1 of 6


Prevention:
P210 Keep away from heat/sparks/open flames/hot surfaces. - No smoking.
P241 Use explosion-proof electrical/ventilating/lighting/equipment

Response:
P303+P361+P353IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with
water/shower.
P305+P351+P338IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to
do. Continue rinsing.

Storage:
P405 Store locked up.

Disposal:
P501 Dispose of contents/container in accordance with local/regional/national/international regulations.

3: PREPARATION COMPOSITION AND INFORMATION ON INGREDIENTS

Chemical characterization
Description: Mixture of substances listed below with nonhazardous additions.

Dangerous components:
CAS: 64742-49-0 Kookpuntbenzine 25 – 50%
EINECS: 265-151-9 Xn, Xi, F, N; R 11-38-51/53-65-67
Danger: 2.6/2; 3.10/1
Warning: 3.2/2, 3.8/3
4.1.C/2
CAS: 110-82-7 Cyclohexane 10 – 25%
EINECS: 203-806-2 Xn, Xi, F, N; R 11-38-50/53-65-67
Danger: 2.6/2; 3.10/1
Warning: 4.1.C/1; 3.2/2, 3.8/3
CAS: 141-78-6 ethyl acetate 10 – 25%
EINECS: 205-500-4 Xi, F; R 11-36-66-67
Danger: 2.6/2
Warning: 3.3/2, 3.8/3
CAS: 136-23-2 zinc bis(dibutyldithiocarbamate) < 2.5%
EINECS: 205-232-8 Xi, N; R 36/37/38-43-50/53
Warning: 4.1.C/1; 3.2/2, 3.3/2, 3.4.S/1, 3.8/3

Additional information: For the wording of the listed risk phrases refer to section 16

4: FIRST AID MEASURES

After inhalation: In case of unconsciousness place patient stably in side position for transportation.
After skin contact: Immediately wash with water and soap and rinse thoroughly.
After eye contact: Rinse opened eye for several minutes under running water.
After swallowing: If symptoms persist consult doctor.

5: FIRE FIGHTING MEASURES


Suitable extinguishing agents:
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
For safety reasons unsuitable extinguishing agents: Water with full jet·
Protective equipment: No special measures required.

6. ACCIDENTAL RELEASE MEASURES

Person-related safety precautions: Wear protective equipment. Keep unprotected persons away.
Measures for environmental protection:
Prevent seepage into sewage system, work-pits and cellars.
Inform respective authorities in case of seepage into water course or sewage system.
Do not allow to enter sewers/ surface or ground water.
Measures for cleaning/collecting:
Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).
Ensure adequate ventilation.

Issue No: 01 Date: 01/04/2011 Proofex OGP Adhesive Page 2 of 6


7: HANDLING AND STORAGE
Handling:
Information for safe handling: Ensure good ventilation/exhaustion at the workplace.
Information about fire - and explosion protection:
Keep ignition sources away - Do not smoke.
Protect against electrostatic charges.

Storage:
Requirements to be met by storerooms and receptacles: Store in a cool location.
Information about storage in one common storage facility: Not required.
Further information about storage conditions:
Keep container tightly sealed.
Store in cool, dry conditions in well sealed receptacles.

8: EXPOSURE CONTROLS/PERSONAL PROTECTION


Additional information about design of technical facilities: No further data; see item 7.

Ingredients with limit values that require monitoring at the workplace:


110-82-7cyclohexane (10-25%)
WELL Short-term value: 1050 mg/m³, 300 ppm
Long-term value: 350 mg/m³, 100 ppm
141-78-6ethyl acetate (10-25%)
WELL Short-term value: 400 ppm
Long-term value: 200 ppm
Additional information: The lists valid during the making were used as basis.

Personal protective equipment:·

General protective and hygienic measures:


Keep away from foodstuffs, beverages and feed.
Immediately remove all soiled and contaminated clothing
Wash hands before breaks and at the end of work.
Do not inhale gases / fumes / aerosols.
Avoid contact with the skin.
Avoid contact with the eyes and skin.

Respiratory protection:
In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-
contained respiratory protective device.
Use suitable respiratory protective device in case of insufficient ventilation.

Protection of hands:

Protective gloves

The glove material has to be impermeable and resistant to the product/ the substance/ the preparation.
Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/the chemical
mixture.
Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation·

Material of gloves
The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from
manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material
cannot be calculated in advance and has therefore to be checked prior to the application.

Penetration time of glove material


The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eye protection:

Tightly sealed goggles

Issue No: 01 Date: 01/04/2011 Proofex OGP Adhesive Page 3 of 6


9: PHYSICAL AND CHEMICAL PROPERTIES
General Information

Form: Fluid
Colour: Black
Odour: Characteristic

Change in condition
Melting point/Melting range: Undetermined
Boiling point/Boiling range: 60°C

Flash point: -18°C


Ignition temperature: 260°C

Self-igniting: Product is not self-igniting.


Danger of explosion: Product is not explosive. However, formation of explosive air/vapour mixtures are possible.

Explosion limits:
Lower: 1.2 Vol %
Upper: 11.5 Vol %

Vapour pressure at 20°C: 175 hPa

Density at 20°C: 0.865 g/cm³

Solubility in / Miscibility with water: Not miscible or difficult to mix.

Viscosity: Dynamic at 20°C: 2500 mPas·

Solvent content: Organic solvents: 56.7 %·

Solids content: 43.3 %

10: STABILITY AND REACTIVITY


Thermal decomposition / conditions to be avoided: No decomposition if used according to specifications.
Dangerous reactions: No dangerous reactions known.
Dangerous decomposition products: No dangerous decomposition products known.

11: TOXICOLOGICAL INFORMATION

Acute toxicity:
LD/LC50 values relevant for classification:
110-82-7cyclohexane
Oral lD50 12705 mg/kg (rat)

Primary irritant effect:


on the skin: Irritant to skin and mucous membranes.
on the eye: No irritating effect.
Sensitization: No sensitizing effects known.
Additional toxicological information:
The product shows the following dangers according to the calculation method of the General EU Classification Guidelines
for Preparations as issued in the latest version:
Irritant

12: ENVIRONMENTAL CONSIDERATIONS

Ecotoxical effects:
Remark: Toxic for fish·
General notes:
Water hazard class 2 (German Regulation) (Self-assessment): hazardous for water
Do not allow product to reach ground water, water course or sewage system.
Danger to drinking water if even small quantities leak into the ground.
Also poisonous for fish and plankton in water bodies.
Toxic for aquatic organisms

Issue No: 01 Date: 01/04/2011 Proofex OGP Adhesive Page 4 of 6


13: DISPOSAL CONSIDERATIONS
Product:
Recommendation
Must not be disposed together with household garbage. Do not allow product to reach sewage system.

European waste catalogue


08 04 09 waste adhesives and sealants containing organic solvents or other dangerous substances

Uncleaned packaging:
Recommendation: Disposal must be made according to official regulations.

14: TRANSPORT INFORMACTION


Land transport ADR/RID (cross-border)

ADR/RID class: 3 (F1) Flammable liquids.


Danger code (Kemler): 33
UN-Number: 1133
Packaging group: III
Hazard label 3
Special marking: Symbol (fish and tree)

Maritime transport IMDG:

IMDG Class: 3
UN Number: 1133
Label 3
Packaging group: III
EMS Number: F-E,S-D
Marine pollutant: Yes - Symbol (fish and tree)
Proper shipping name: ADHESIVES

Air transport ICAO-TI and IATA-DGR:

ICAO/IATA Class: 3
UN/ID Number: 1133
Label 3
Packaging group: III
Proper shipping name: ADHESIVES

UN "Model Regulation": UN1133, ADHESIVES, 3, III


Environmental hazards:
Product contains environmentally hazardous substances: cyclohexane, Kookpuntbenzine 60-95

15: REGULATORY INFORMATION

Labelling according to EU guidelines:


The product has been classified and marked in accordance with EU Directives / Ordinance on Hazardous Materials.

Code letter and hazard designation of product:

Xi Irritant
F Highly flammable
N Dangerous for the environment

Xi Irritant
F Highly flammable
N Dangerous for the environment

Issue No: 01 Date: 01/04/2011 Proofex OGP Adhesive Page 5 of 6


Risk phrases:
11 Highly flammable
38 Irritating to skin
51/53 Toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment
67 Vapours may cause drowsiness and dizziness

Safety phrases:
3 Keep in a cool place
9 Keep container in a well-ventilated place
16 Keep away from sources of ignition - No smoking
21 When using do not smoke
23 Do not breathe fumes
57 Use appropriate container to avoid environmental contamination

Special labeling of certain preparations:


Contains zinc bis (dibutyldithiocarbamate). May produce an allergic reaction

National regulations:

Technical instructions (air):

Class Share in %
NK 56.7

Water-hazard class: Water hazard class 2 (Self-assessment): hazardous for water

16: OTHER INFORMATION

This information is based on our present knowledge. However, this shall not constitute a guarantee for any specific product
features and shall not establish a legally valid contractual relationship.

Relevant R-phrases
11 Highly flammable
36 Irritating to eyes
36/37/38 Irritating to eyes, respiratory system and skin
38 Irritating to skin
43 May cause sensitization by skin contact
50/53 Very toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment
51/53 Toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment
65 Harmful: may cause lung damage if swallowed
66 Repeated exposure may cause skin dryness or cracking
67 Vapours may cause drowsiness and dizziness.
Abbreviations and acronyms:
ADR: Accord European sur le transport des merchandises dangerousness par Route (European Agreement concerning the
International Carriage of Dangerous Goods by Road)
RID: Regalement international concernant le transport des merchandises dangerousness par chemin de fer (Regulations
Concerning the International Transport of Dangerous Goods by Rail)
IMDG: International Maritime Code for Dangerous Goods
IATA: International Air Transport Association
IATA-DGR: Dangerous Goods Regulations by the "International Air Transport Association"
(IATA) ICAO: International Civil Aviation Organization
ICAO-TI: Technical Instructions by the "International Civil Aviation Organization" (ICAO)
GHS: Globally Harmonized System of Classification and Labeling of Chemicals
LC50: Lethal concentration, 50 percent
LD50: Lethal dose, 50 percent·
* Data compared to the previous version altered.

Date Printed: 01/04/2011 Issue No: 01 MSDS Reference: FOSROC/ Proofex OGP Adhesive

Issue No: 01 Date: 01/04/2011 Proofex OGP Adhesive Page 6 of 6


Method Statement
Method Statement
Fosroc Proofex OGP/ORG constructive solutions

Section A : General Comments

Equipment

It is suggested that the following list of protective clothing ,equipment , tools ,accessories and list of
testing equipments are available :

Protective clothing

1- Protective overalls
2- Good quality gloves

Application equipment

A- LEISTER TRIAC AT (control electric): for single welding (hot air gun)
B- LEISTER VARIMAT : for automatic single welding
C- LEISTER TWINNY T/S : for automatic double seam welding

Application tools

A- knife cutters
B- one arm rubber and metal rollers for LEISTER TRIAC AT
C- screw drivers with hook finish

Accessories

A- Fosroc solvent 102 (cleaner) or Equipment Cleaner


B- Fosroc Proofex Metal Strip

Testing equipments

A- Air pressure testing needle with gauge.


B- Air pressure pump. (Calibration Certificate should be attached)

www.fosroc.com
constructive solutions

Section B : Application Method

1.0 Surface Preparation

1.1 Clean all concrete surfaces and assure them to be free of laitance, dust, dirt, cavities,
projecting nibs etc.

1.2 Surfaces must be dry and smooth.

1.3 Wall/Floor slab junctions should be made smooth using a sand/cement mortar fillet.

2.0 Application – Horizontal

2.1 CONCRETE SUBSTRATE: Lay a separation Geotextile membrane (non woven


polypropylene min 340 gr/m2) over the concrete roof slab as loose laid with 100mm overlaps
to protect the Fosroc Proofex OGP/ORG from friction and abrasion stresses. There is no
requirement for geotextile when applying the membrane on top of EPS insulation.

METAL DECK SUBSTRATE: Lay a suitable vapour barrier as determined by the Engineer.
Lay suitable insulation boards on top of the vapour barrier as determined by the Engineer.
Mechanically fix the insulation boards to the metal deck using plastic tubes and carbon
screws as determined by the Engineer.

2.2 Lay the first roll of Fosroc Proofex OGP/ORG and mechanically fix it to the substrate along
the roll edge using plastic tubes and carbon screws, fixed at least 30mm into the substrate.

2.3 Lay adjacent roll making sure that 80mm overlap is achieved, continue with other rolls.

2.4 Prepare the LEISTER welding equipment (or equivalent) to the required temperature of
approximately 350 degree C.

Note: carrying out a sample of the welding after temperature calibration is recommended to achieve
correct consistency of weld.

2.5 Spot weld the first 30mm of the overlap area (from inside) at 300-500mm centres along the
membrane using the LEISTER TRIAC AT

2.6 After completing the spot welding pre-weld the joints using the LEISTER TRIAC AT

2.7 Complete the full welding using the LEISTER TRIAC AT with rubber roller

2.8 When using the LEISTER VARIMAT automatic machine there is no need for the spot and
pre-welding process

Page 2 of 4
constructive solutions

2.9 Extend the ends of the horizontal membrane for a further 300 mm for subsequent welding
with vertical membrane at upstands.

2.10 When changing the directions of the membrane where T-case is expected then all joints
under the over lapped locations should be welded and melted again using the metal rollers
along with LEISTER TRIAC AT. Otherwise patch strip to be used.

2.11 Non permanently exposed horizontal areas shall be protected by either a cement sand
screed of minimum thickness 50mm or by using a non woven polypropylene geotextile of 140
gr/m2

3.0 Application – Vertical

3.1 Fix Fosroc Proofex Metal Strip at required height of upstand with TPO coated face exposed.

3.2 Weld Fosroc Proofex OGP/ORG to Fosroc Proofex Metal Strip then to adjoining horizontal
membrane. (See standard CAD details)

3.3 Finish off with Nitoseal MS60 sealant and Flashing to suit.

4.0 Testing

4.1 Screw driver with hook finish

After completing the welding of any joint it is recommended to pass this screw driver with
hook finish along the joints with some side push to make sure that the joints are welded
properly.
Defects rectified by welding a fresh piece of membrane over the affected area.

4.2 Air pressure gauge for double welded joints

A - Fix the needle and connect it to the gauge


B - Close both sides of the double welded joint created air seal
C - Connect the machine and the compressor and start pressurising to reach 2 bar pressure
D - Maintain the pressure for 5 minutes
E - If the pressure remains constant or looses less than 20% of the original reading (2 bar)
then weld is accepted (UNI 10567)
F - If the pressure looses more than 20% of the original reading (2 bar ) then it is deemed to have failed .
G -To determine the leakage point, foam (water + soap) can be used

Page 3 of 4
constructive solutions

4.3 Vacuum box method

A- Apply some foam (water and soap) on top of the location to be tested
B- Fix the vacuum box on top of this location
C- Connect the vacuum box to a suction pump
D- The membrane will start showing bubbles if there are punctures in the membrane or there
has been a substandard welding of the joints

Section C : Approval and variations

This method statement is offered by Fosroc as a ‘standard proposal’ for the application of Fosroc
Proofex OGP/ORG. It remains the responsibility of the Engineer to determine the correct method for
any given application. Where alternative methods are to be used, these must be submitted to Fosroc
for approval, in writing, prior to commencement of any work. Fosroc will not accept responsibility or
liability for variations to the above method statement under any other condition.

Page 4 of 4
Test Reports
Fosroc Singapore
6 Serangoon North Avenue 5 #02-05
Singapore 554910

FOSROC PROOFEX OFB/OGP/ORG


032-032-2325
Environmentally Preferred Coating
(In accordance to SEC Green Label Category 32: Paints and Surface Coatings)

Validity: 2 June 2020 to 1 June 2021


INSPECTION CERTIFICATE
Extension of the certificate n° M43052/11/DB/db

BV Job nr. 20.IT3814918.174 doc. Chrono J04538/20/RG/am


Project: NA Ref: NA

BV Client: P/o nr: 20.IT3814918.174


Fosroc International Limited
Drayton Manor Business Park,
Coleshill Road,
Tamworth,
Staffordshire
B78 3XN
Inspection request by:
Fosroc International Limited
Drayton Manor Business Park,
Coleshill Road,
Tamworth,
Staffordshire
B78 3XN

Supply/Subject of Inspection ITEM/TAG QTY


Waterproofing Type: NA NA
• PROOFEX PGP
• PROOFEX OGP
• PROOFEX ORG
• PROOFEX OFB
• PROOFEX ORF

Inspection:
Place of inspection:
Laboratory Business Unit Marano Ticino (Italy)
Date of inspection:
15 July 2020
This certificate includes n. 6 pages

The undersigned, inspector to Bureau Veritas, certifies that the here above mentioned supply was
inspected in conformity with the applicable requirements of the purchase order and the contractual
requirements governing the mission entrusted by Bureau Veritas without any remarks.

Inspected by:
Name: Stamp & Signature:
Daniela Mannina

Data of iusse: 07 August 2020_ extension of the validity


Inspection Centre: BV Milan

Distribution: Client □ Manufacturer BV Milan □ _____


1/8
INSPECTION CARRIED OUT:
The undersigned Surveyor of Bureau Veritas Italy S.p.A. declares that on date 15 July 2020 witnessed
the following tests, according to Manufacturer Technical Data Sheets and under applicable Standards
1. Carried out under mentioned product identification
2. Collecting samples on the above mentioned products to carried out laboratory tests as per
Manufacturer request
3. Verified calibration status of the instruments used for under mentioned tests
4. Verified the temperature and UR% inside the laboratory, where the specimen where stored
before the tests.

Trade Mark:
PROOFEX PGP

Production Reference Composition

Thickness Surface
Batch ref. Compound Reinforcement Intended for
(or Weight) finishing
21/05/2020 - IM 2000000528 1,5 mm
PVC-P --- --- EN 13361 – EN 13362 – EN 13491
19/05/2020 – IM 2000000468 2,0 mm

5. Witnessed following Manufacturer tests:

Type of Test Unit Standard Acceptance Reference Values Measured Values


ref. deviation

Thickness mm EN 1849-2 ±5% 1,5 2,0 1,45 2,17


Tensile strength Long N/mm2 EN 12311-2 B ≥ 17 18,1 17,2
Tensile strength Transv. N/mm 2
EN 12311-2 B ≥ 17 18,9 18,1
Elongation at break Long. % EN 12311-2 B ≥ 300 343 355
Elongation at break Transv. % EN 12311-2 B ≥ 300 338 355
Dynamic Puncture Resistance mm EN 12691 / B 1punct./5 750 750/Pass
Shear Resistance of the Joint N/50mm EN 12317/2 ≥ Broken out joint Broken out joint
Tear Test Long Long N EN 12310-1 ≥ 360 480 586 719
Tear Test Long Trasv N EN 12310-1 ≥ 360 480 514 814
Peel resistance of Joint N/cm EN 12316-2 ≥ 58 PASS (74)

6. Reviewed following Manufacturer declarations and tests Report (Not witnessed by


BureauVeritas)

Type of Test Unit Standard Acceptance Reference Values Measured values Document
ref deviation (for nominal thickness) (for nominal thickness) ref.

1,50 2,00 1,51 2,04


Cold Flexibility °C EN 495-5 ≤ - 35 - 35 CF-S/09.562.233 (*)
Static puncture resistance EN 12370
Kg MET.A ≥ 20 20 25 25 BV-S.PGP-SL/11.05.05
MET. B ≥ 25 25 25 25

TECNOPIEMONTE
kN EN 12236 ≥ 2,5 3 2,58 3,12
00879/38/65
Water impermeability Mpa EN 1928 ≥ 0,5 Pass test BV-S.PGP-WT/11.05.06

(*) Test performed by the thickness 2 mm; Test witnessed only by the thickness 1,5 mm.

2/8
Stamp & Segnature:
Trade Mark:
PROOFEX OGP
Production Reference Composition
Batch ref. Compound Reinforcement Thickness (or Weight) Surface finishing Intended for

12/04/2019 - IM 1900000563 TPO-FPA --- 1,2 mm --- EN 13956


10/07/2020 - IM 2000000836 1,5 mm

7. Witnessed following Manufacturer tests:

Type of Test Unit Standard Acceptance Reference Values Measured Values


ref deviation

Thickness mm EN 1849-2 ±5% 1,2 1,5 1,21 1,61


Areic mass Kg/m2 EN 1849-2 ± 10 % 1,08 1,35 1,09 1,45
Tensile strength Long N/mm2 EN 12311-2 B ≥ 16 17 17,4
Tensile strength Transv. N/mm 2
EN 12311-2 B ≥ 15 16,5 15,9
Elongation at break Long. % EN 12311-2 B ≥ 700 928 758
Elongation at break Transv. % EN 12311-2 B ≥ 700 983 741
Dynamic Puncture Resistance mm EN 12691/B 1punct./5 1000 1000 / Pass
Shear Resistance of the Joint N/50mm EN 12317/2 ≥ RT / Broken out joint PASS
Peel resistance of Joint N/cm EN 12316-2 ≥ 58 PASS (84,3)
Tear Test Long N EN 12310-1 ≥ 330 450 532,5 617
Tear Test Trasv N EN 12310-1 ≥ 240 400 474 623
Cold Flexibility °C EN 495-5 ≤ - 40 Pass – 40 (*)
(*) Test witnessed only by the thickness 1,2 mm

8. Reviewed following Manufacturer declarations and tests Report (Not witnessed by Bureau
Veritas)

Type of Test Unit Standard Acceptance Reference Values Measured Values Document
ref. deviation (for nominal (for nominal ref.
thickness) thickness)

1,2 1,5 1,17 1,49


Cold Flexibility °C EN 495-5 ≤ -40 - 40 Pass – 40 CF-S/09.562.243 (*)
Dim. Stability Long. % EN 1107-2 ≤ 0,5 0,41
DS-S/09.562.243
Dim. Stability Trasv. % EN 1107-2 ≤ 0,5 0,29
Water Vapour transmission μ EN 1931 MET. B ± 30% 90000 93460 Pass WVT-S/09.562.243(**)
Resistance Static Load EN 12370
- Soft support Kg MET. A ≥ 20 20 Pass
SL-S/09.562.243
- Hard support MET. B ≥ 25 25 Pass
Water impermeability kPa EN 1928-B ≥ 60 Pass Test WT-S/09.562.243
Ist. Politecnico 04/1998
Hail resistance m/s EN 13583 ≥ 26 29
(**)
Durability
-- ITC Report (**)
- Resistance UV (2500h) - EN 1297 NL NL
3503/rp/02
- Cold flexibility after expos UV °C EN 495-5 ≤ - 30 -30
Ageing in air :
- Tensile Strength L/T N/mm2 EN 12311-2 ≥ -5 % VN 16,3/15,8 OX-S/09-562.243 (**)
- Elongation L/T % EN 12311-2 ≥ -5 % VN 678/749
3/8
Stamp & Segnature:
BV-S.OGP-WA/11.05.11
Water Absorbition % UEatc ≤ 2% 0,14 0,17
WA-S/09.562.243
CSTC DE651 XC 392
Wind uplift resistance Pa UEatc ≥ 5500 5500
(**)
Cert Lapi 472.ODC0050/08
Fire Rating Euroclass EN 13501-1 --- E E
(**)
University Liegi
Resistance to micro organism -- EN 846 Liv 2 --- Resist Pass
5/65.828/3 (**)
Root resistance -- EN:13948 --- Resist Pass BDA KEUR 0106-L-10/1
D.M. 06/04/2004 Cert.Camera Comm.
Contact with potable water --
nr. 174 -- No toxic No toxic
7166/2011 (**)
(*) Test performed by the thickness 1,5 mm; Test witnessed only by the thickness 1,2 mm.
(**) Independent test of the thickness or carried on inferior thickness and applicable on greater thickness

Trade Mark:
PROOFEX ORG

Production Reference Composition

Batch ref. Compound Reinforcement Thickness (or Surface finishing Intended for
Weight)
21/02/2020 - IM 2000000273 1,2 mm
TPO-FPA Glass fiber --- EN 13956
12/02/2020 - IM 1900000182 1,5 mm

9. Witnessed following Manufacturer tests:

Type of Test Unit Standard Acceptance Reference Values Measured Values


ref deviation

Thickness mm EN 1849-2 ±5% 1,2 1,5 1,23 1,56


Areic mass Kg/m2 EN 1849-2 ± 10 % 1,10 1,37 1,13 1,43
Tensile strength Long N/50mm EN 12311-2 A ≥ 600 650 722 714
Tensile strength Transv. N/50mm EN 12311-2 A ≥ 550 600 613 602
Elongation at break Long. % EN 12311-2 A ≥ 700 700 1046 1013
Elongation at break Transv. % EN 12311-2 A ≥ 700 700 1049 993
Dynamic Puncture Resistance mm EN 12691/B 1punct./5 1000 1000/Pass
Shear Resistance of the Joint N/50mm EN 12317/2 ≥ RT / Broken out joint Conform
Peel resistance of Joint N/cm EN 12316-2 ≥ 58 Conform
Tear Test Long Long N EN 12310-1 ≥ 390 450 599 681
Tear Test Long Trasv N EN 12310-1 ≥ 290 400 527 615
Cold Flexibility °C EN 495-5 ≤ - 40 Pass – 40 (*)

(*) Test witnessed only by the thickness 1,2 mm

10. Reviewed following Manufacturer declarations and tests Report (Not witnessed by Bureau
Veritas)

Type of Test Unit Standard Acceptance Reference Values Measured Values Document
ref deviation (for nominal (for nominal Ref.
thickness) thickness)

1,2 1,5 1,199 1,52


Cold Flexibility °C EN 495-5 ≤ - 40 Pass - 40 CF-S/09.562.283 (*)

4/8
Stamp & Segnature:
Dim. Stability Long % EN 1107-2 ≤ 0,1 0,06
DS-S/09.562.283
Dim. Stability Trasv. % EN 1107.2 ≤ 0,1 0,01
EN 1931
Water Vapour transmission μ MET. B
± 30% 50000 56430 Pass WVT-S/09.562.283 (**)
Resistance Static Load EN 12370
- Soft support Kg MET. A ≥ 20 20 Pass BV-S.ORG-SL/11.05.07
- Hard support MET. B ≥ 25 25 Pass SL-S/09.562.283
Water impermeability kPa EN 1928-B ≥ 60 60 WT-S/09.562.303
Ist. Politecnico 04/1998
Hail resistance m/s EN 13583 ≥ 26 29
(**)
Durability
-- NL ITC Report (**)
- Resistance UV (2500h) - EN 1297 NL
3503/RP/02
- cold flexibility after expos UV °C EN 495-5 ≤ ≤ -30 -30
Ageing in air
- Tensile Strength L/T N/mm2 EN 12311-2 ≥ -5 % VN 721/601 OX-S/09-562.313 (**)
- Elongation L/T % EN 12311-2 ≥ -5 % VN 1001/956
BV-S.ORG-WA/11.05.89
Water absorbition % UEatc ≤ 2% 1,21 1,49
WA-S/09.562.313
CSTC DE651 XC 797
Wind uplift resistance Pa UEatc ≥ 5600 5500
(**)
Cert Fire Lab
Fire Rating Euroclass EN 13501-1 --- E E
FLTKE2157207 (**)
University Liegi
Resistance to micro organism -- EN 846 Liv 2 --- Resist Pass
5/65.828/3 (**)
Root resistance -- EN:13948 --- Resist Pass BDA KEUR 0106-L-10/1
D.M.
Cert.Camera Comm.
Contact with potable water -- 06/04/2004 -- No toxic No toxic
7166/2011 (**)
nr. 174
(*) Test performed by the thickness 1,5 mm; Test witnessed only by the thickness 1,2 mm.
(**) Independent test of the thickness or carried on inferior thickness and applicable on greater thickness

Trade Mark:
PROOFEX OFB

Production Reference Composition

Thickness Surface
Batch ref. Compound Reinforcement Intended for
(or Weight) finishing
20/06/2019 - IM 1900000890 1,2 mm Polyeter
14/11/2019 - IM 1900001631 TPO-FPA ---- 1,5 mm fleece on the EN 13956
bottom

11. Witnessed following Manufacturer tests (1):

Type of Test Unit Standard Acceptance Reference Values Measured Values


ref. deviation

Thickness mm EN 1849-2 ±5% 1,2 1,5 1,21 1,60


Areic mass (*) Kg/m2 EN 1849-2 ± 10 % 1,24 1,51 1,25 1,61
Dynamic Puncture Resistance (*) mm EN 12691/B 1punct./5 1800 1800/Pass
Tear Test Long Long (*) N EN 12310-1 ≥ 450 650 808 1024
Tear Test Long Trasv (*) N EN 12310-1 ≥ 400 500 826 933

(1) For TPO/FPA membrane layer, unless when shown (*)

5/8
Stamp & Segnature:
12. Reviewed following Manufacturer declarations and tests Report (Not witnessed by Bureau
Veritas)

Type of Test Unit Standard Acceptance Reference Values Measured Values Document
ref deviation (for nominal thickness) (for nominal thickness) Ref.

1,2 1,5 1,191 1,47


Cold Flexibility °C EN 495-5 ≤ - 40
Tensile strength Long N/mm2 EN 12311-2 ≥ 16
Tensile strength Transv. N/mm2 EN 12311-2 ≥ 15
Elongation at break Long. % EN 12311-2 ≥ 700
Elongation at break Transv. % EN 12311-2 ≥ 700
Shear Resistance of the Joint N/50m
EN 12317/2 ≥ RT / Broken out joint
m
Peel resistance of Joint N/cm EN 12316-2 ≥ 58

Dim. Stability Long % EN 1107-2 ≤ 0,5


Dim. Stability Trasv. % EN 1107.2 ≤ 0,5
EN 1931
Water Vapour transmission μ MET.B
± 30% 90000
Resistance Static Load (*)
- Soft support Kg EN 12370 ≥ 20
- Hard support ≥ 25 In conformity with
Water impermeability kPa EN 1928-B ≥ 60 results on
See Proofex OGP
Proofex OGP
Hail resistance m/s EN 13583 ≥ 26 of same thickness
Durability
- Resistance UV (2500h) - EN 1297 -- NL
- Cold flexibility after expos UV °C EN 495-5 ≤ ≤
Ageing in air:
- Tensile Strength L/T
N/mm2 EN 12311-2 ≥ -5 % VN
- Elongation L/T
% EN 12311-2 ≥ -5 % VN

Water Absorbition % UEatc ≤ 2%


Wind uplift resistance (*) Pa UEatc ≥ 5500

Resistance to micro organism -- EN 846 Liv 2 --- Resist


Root resistance -- EN:13948 --- Resist
D.M.
Contact with potable water -- 06/04/2004 -- No toxic
nr. 174

Trade Mark:
PROOFEX ORF
Production Reference Composition
Batch ref. Compound Reinforcement Thickness (or Weight) Surface finishing Intended for

22/10/2019 - IM 1900001514 Polyester/ 1,5 mm


TPO-FPA --- EN 13956
25/05/2020 - IM 2000000542 glass fibers 1,8 mm

6/8
Stamp & Segnature:
13. Witnessed following Manufacturer tests:

Type of Test Unit Standard Acceptance Reference Values Measured Values


ref deviation

Thickness mm EN 1849-2 ±5% 1,5 1,8 1,44 1,85


Areic mass Kg/m2 EN 1849-2 ± 10 % 1,85 2,25 1,81 2,29
Tensile strength Long N/50 mm EN 12311-2 A ≥ 1100 1233 (*)
Tensile strength Transv. N/50 mm EN 12311-2 A ≥ 1100 1215 (*)
Elongation at break Long. % EN 12311-2 A ≥ 25 30 (*)
Elongation at break Transv. % EN 12311-2 A ≥ 25 30 (*)
Dynamic Puncture Resistance mm EN 12691/B 1punct./5 1200 1200 / Pass(*)
Shear Resistance of the Joint N/50mm EN 12317/2 ≥ RT / Broken out joint PASS(*)
Peel resistance of Joint N/cm EN 12316-2 ≥ 58 PASS(*)
Tear Test Long Long N EN 12310-1 ≥ 600 1022(*)
Tear Test Long Trasv N EN 12310-1 ≥ 550 639(*)
Cold Flexibility °C EN 495-5 ≤ - 40 Pass – 40 (*)(*)

(*) Test witnessed only by the thickness 1,5 mm


(*)(*) Test witnessed only by the thickness 1,8 mm

14. Reviewed following Manufacturer declarations and tests Report (Not witnessed by Bureau
Veritas)

Type of Test Unit Standard Acceptance Reference Values Measured Values Document
ref. deviation (for nominal (for nominal ref.
thickness) thickness)

1,5 1,8 1,44 1,95


Cold Flexibility °C EN 495-5 ≤ -40 - 40 Pass – 40 CF-S/20.019.853 (*)
Dim. Stability Long. % EN 1107-2 ≤ 0,1 0,05 *
DS-S/20.019.853.1
Dim. Stability Trasv. % EN 1107-2 ≤ 0,1 0,02*
Water Vapour transmission μ EN 1931 MET. B ± 30% 50000 56430 Pass WVT-S/09.562.283
Resistance Static Load EN 12370
- Soft support Kg MET. A ≥ 20 20 Pass SL-S/19.019-853.21
- Hard support MET. B ≥ 25 25 Pass
WT-S/20.019.853.2
Water impermeability kPa EN 1928-B ≥ 60 PASS
WT-S/20.019.853.5
FM
Hail resistance
Rating
FM ASt 4470 ≥ 1-SH PASS FM Approval 3063900

Durability
-- ITC Report (**)
- Resistance UV (2500h) - EN 1297 NL NL
3503/RP/02
- Cold flexibility after expos UV °C EN 495-5 ≤ - 30 -30
Ageing in air:
- Tensile Strength L/T N/50mm EN 12311-A ≥ -5 % VN 1070 / 1064 OX-S/20.019.853.9
- Elongation L/T % EN 12311-A ≥ -5 % VN 25,4 / 24,9
Wind uplift resistance FM rating FM ASt 4470 105 FM Class PASS FM Approval 3063900
Fire test FM rating ASTM E 108 Class A-1/4 in 12 PASS FM Approval 3063900
University Liegi /65.828/3
Resistance to micro organism -- EN 846 Liv 2 --- Resist Pass
(**)
Root resistance -- EN:13948 --- Resist Pass BDA KEUR 0106-L-10/1

(*) Test performed by the thickness 1,8 mm


(**) Independent test of the thickness or carried on inferior thickness and applicable on greater thickness

7/8
Stamp & Segnature:
Final Result:

All the above mentioned inspections have been found in compliance with the Standard mentioned on
the Manufacturer Technical Data Sheet Declaration and EN Standard Applicable.

Bureau Veritas Italy Inspector


Daniela Mannina
Technical maneger
Ing.Remo Godino

8/8
Stamp & Segnature:
Fosroc offers a full range of construction chemical solutions, helping to protect structures
throughout the world. Please refer to our brochures, which include:

Malaysia China Indonesia Singapore


Fosroc Sdn. Bhd Fosroc Guangzhou Limited PT. Fosroc Indonesia Fosroc Singapore
Tel : +6 03 5102 5660 Tel : +86 20 8226 9245 Tel : +62 21 897 2103 Tel: +65 6665 3828
Enquirymalaysia@fosroc.com enquiryhongkong@fosroc.com enquiry.indonesia@fosroc.com enquirysingapore@fosroc.com

Thailand Hong Kong Vietnam Rest of Southeast Asia


Fosroc Thailand Fosroc Hong Kong Fosroc Vietnam Fosroc Construction Chemicals Pte Ltd
Tel : +66 2 136 9898 Tel : +85 22 882 8662 Tel : +82 222 3765 971 Tel : +65 6665 3828
Enquirythailand@fosroc.com enquiryhongkong@fosroc.com enquiryvietnam@fosroc.com enquiry.FGTAsia@fosroc.com

www.fosroc.com
Important Note
Fosroc products are guaranteed against defective materials and manufacture and
are sold subject to its standard terms and condition of sale, copies of which may
be obtained on request. Whilst Fosroc, endeavors to ensure that any advice,
recommendation, specification or information it may give is accurate and correct,
it cannot, because it has no direct or continuous control over where or how its
products are applied, accept any liability either directly or indirectly arising from
the use of its products, whether or not in accordance with any advice, constructive solutions
specification, recommendation or information given by it.

You might also like