Retail Outlet Inspection Report: A. Sales & Stock 1. Totalizer Readings
Retail Outlet Inspection Report: A. Sales & Stock 1. Totalizer Readings
-85085
Address : HPCL PETROL PUMP Date of Inspection : 06-12-2013
TOSHAM BEHAL ROAD Name of Officer : JINDAL PRINCE
VPO TOSHAM Date of Previous Regular : 21-12-2012
Pincode : 127040 Inspection
Revenue District : HR-BHIWANI
Type of Station : serviceStation
Regional Office : GURGAON Retail RO
Date MS HSD
From To R (in KL) T (in Litres) R (in KL) T (in Litres)
21-12-2012 06-12-2013 290000 555 1394000 6660
Total 290000 555 1394000 6660
2. Stock in Tanks
Tank No. Capacity Stock on Previous Product Actual Stock on Date Dip in CM.
(In Litres) Visit of Inspection
(in Litres) (in Litres)
MS-1 16000 3543 MS 7440 90.2
HSD-1 45000 8010 HSD 21500 140.3
Product Previous Stock in all Receipts since last Total Stock Total Sales as per Dip
tanks Inspection (in Litres) (in Litres)
(in Litres) (in Litres)
MS 3543 290000 293543 286103
HSD 8010 1394000 1402010 1380510
Variation Details
MS HSD
Prev. Opn. Stock 3543 8010
Receipts 290000 1394000
Total Stock 293543 1402010
Today's Stock 7440 21500
Dip Sale 286103 1380510
Meter Sale 284637 1381272
+/- Var. -1466 762
% Var. -0.51 0.06
4% Stock Var. 298 860
Var. in permissible limit Yes Yes
B. Performance Review
For the Month Cummulative Year
S. Target Sale in Sale in Target Sale in Sale in
No. November November April-2013 to April-2012 to
2013 2012 November-2013 November-2012
1 MS 0.00 30.00 30.00 400.00 200.00 164.00
2 HSD 0.00 172.00 114.00 2400.00 1032.00 908.00
3 Lubes uplifted from the company
a) Racer2 0.00 0.00 0.00 0.30 0.00 0.00
b) Other AEGO 0.00 0.00 0.00 2.70 0.00 0.00
c) Total Lubes 0.00 0.00 0.00 3.00 0.00 0.00
d) Lube Fuel Ratio 0.00 0.00 0.00 0.11 0.00 0.00
e) Racer2/MS Ratio 0.00 0.00 0.00 0.08 0.00 0.00
Page 1 of..6..
C. Daily Sales Record Verification
Current Product Average Sales per No. of Days (Nil Dates of Dry Out period Reasons for Nil sales / Dry Outs
Day Sales)
MS 814.83 0
HSD 3965.52 0
F. Availability / Condition
Availability Condition
Adequate Lighting Yes Available
Toilet Yes Available
Drinking Water Yes Available
Free Air Service Yes Available
Radiator Water Yes Available
Telephone Yes Available
First Aid Box Yes Available
G. Scheme of Discipline
a) Correct Prices displayed / charged for MS Yes
Prices for MS (Rs./Litre) 71.90
b) Correct Prices displayed / charged for HSD Yes
Prices for HSD (Rs./Litre) 52.51
c) Correct Prices displayed / charged for POWER N/A
Prices for POWER (Rs./Litre)
d) Correct Prices displayed / charged for TURBOJET N/A
Prices for TURBOJET (Rs./Litre)
e) Correct Prices displayed / charged for Lubes N/A
Prices for Racer-2 (Rs./Litre) No loose sale
f) Correct Prices displayed / charged for CNG N/A
Prices for CNG (Rs./Litre)
g) Correct Prices displayed / charged for Auto LPG N/A
Prices for Auto LPG (Rs./Litre)
h) Working hours board displayed Yes
Working Hours 24 Hrs
i) Telephone number displayed of concerned Field Officer / Regional Office to Yes
be contacted in case of complaints
j) Poster for Customer Service Cell and Education displayed Yes
k) Message regarding availability of suggestion complaint book prominently Yes
displayed
l) Suggestion / Complaint book inspected Yes
H.
a) Presence of Water checked in MS / HSD (wherever applicable) tanks. If Yes
water found, action taken
Remarks, If any Nil water
J.
a) Density register maintained by Dealer Yes
b) Calibrated Hydrometer & Thermometer Available Yes
Remarks, if any
c) Samples of last 2 supplies maintained Yes
d) Inter-connection in tank No
e) Fire Exinguishers properly kept & duly tested Yes
f) Dip Pipes Closed During Decantation Yes
g) Only Metal Embreaded Hose and Metalic Buckets are used during Yes
Decanitation
h) Earthing / Bonding being done before Start Of Decantation Yes
i) The vent pipes are in proper position and their height are as per exposive Yes
noms
j) Provision Of Earthing pit / clamps Yes
k) Sand Buckets in good condition with clean & dry Sand Yes
l) Please Switch Off Mobile Phone message prominently visible Yes
K.
a) Message regarding zeroing of pump meter displayed Yes
b) First Aid box available / contents checked Yes
c) Filter paper available Yes
d) 5 ltrs. measures (duly calibrated / stamped by W & M) available Yes
e) Inspection report files maintained Yes
f) Explosives rules displayed No
Page 2 of..6..
L. Report on Inspection of Pump Delivery
Dispensing Unit Nozzle No. Dispensed Shortage/Excess Short / Excess / Weight and Totalizer
Quantity in ml., if any, OK Measures seal intact
in 5 Ltrs. seal intact
DU-1 MS1 5.0 0.0 OK Yes Yes
DU-2 HSD-1 5.0 0.0 OK Yes Yes
M. Report on Density
Density Check Conducted Yes Yes
Tank No. Product in Density at 15 degree C Density at 15 Sample Variation Is Variation within Remarks
Tank as ascertained at the degree C as per Drawn permissible limit?
time of Inspection dealer's record
MS-1 MS 751.9 751.8 No 0.1 Yes
HSD-1 HSD 830.1 830.5 No -0.4 Yes
Name / Designation / Signature of inspecting Personnel Name / Signature and Seal of the Dealer / Dealer Representative
Page 3 of..6..
Annexure to "Inspection Report by Field Officer"
B. Safety
Name / Designation / Signature of inspecting Personnel Name / Signature and Seal of the Dealer / Dealer Representative
Page 4 of..6..
Comments on Loyalty Programme To start cheque facility immediatley
Automation
a) Automated ? No
b) Automation functioning ? No
c) Comments on Automation No comments
d) Operating automated RO in Manual Mode without No
Authorization ?
Safety Inspection
a) Routine Safety Inspection Conducted No
b) Yearly Safety Inspection Conducted No
Comments on Safety
-Dealer to ensure that all safety practices are followed at retail outlet
Name / Designation / Signature of inspecting Personnel Name / Signature and Seal of the Dealer / Dealer Representative
Page 5 of..6..
REPORT ON SCRAP
No. of DUs : 0
No. of Tanks : 0
Any other Material :
Name / Designation / Signature of inspecting Personnel Name / Signature and Seal of the Dealer / Dealer Representative
Page 6 of..6..