B

A
-

4.673°
BOLTED JOINT 4.673° 4.673° BOLTED JOINT

2.997° 2.997°
P2-02 PP2-03

R146012
R147044

6000
RAIL LVL

3000 2000 3000 3999 3999 3999 3999 3999 3999 3999 3999 3999 3999 3999 3999 3000 2000

B
-

LONGITUDINAL ELEVATION
SCALE : 1/100

GROUND LVL GROUND LVL


MIN.

MIN.
500

500
KICKER LEVEL KICKER LEVEL

A
-

PROPOSED RAIL LEVEL (m) 32.428 32.418

GROUND LEVEL (m) 10.251 17.909

CHAINAGE (m) 12411.821 12471.821

3000 3999 3999 3999 3999 3999 3999 3999 3999 3999 3999 3999 3999 3000

500
2395

5050
5050

1510 1145 1145 1510


10100

10100
11050
11100
BRIDGE AXIS
5050

5050
2395
500

PLAN VIEW
SCALE : 1/100
N

12
MAJURA GATE
NI NAL
11

CH:12313.8
KADARSHA
CH:11721.7

13
ROOPALI
CANAL
CH:13611.5

A0 First Issue MK PJ DA 10/06/2020


KADARSHA ALTHAN
14
CH:14696.2
TENAMENT

DREAM
REV. PARTICULARS DRN. CHD. VER. DATE
NI NAL CITY NOTES :
ALTHAN
15
GAM
CH:
15843.5

16

PROJECT NAME :
VIP
CH: ROAD
16699.1

20 CITY
DREAM
STN. 20710.3
C/L OF CH:

SURAT
CH:
17
WOMEN
17808.4 ITI

18
BHIMRAD
CH:
18659.5
SHIFTED
LOCATION
19
OF CONVENTION
CH:
CENTRE
STN.

1. FOR GENERAL NOTES PLEASE REFER DRAWING NO. DDCSMP1-TD-ELV-ST-DW-04402 & 04403. DETAILED DESIGN CONSULTANCY SERVICES FOR CORRIDOR -1 FROM KADARSHA NI NAL (11721.7)
2. ALL DIMENSIONS ARE TENTATIVE & LIKELY TO CHANGE DURING DETAIL DESIGN. TO DREAM CITY (21610.3) ELEVATED VIADUCT & ELEVATED METRO-RAIL STATIONS - (10 NOS.)
KEY PLAN INCLUDING VIADUCT PORTION WITHIN THE STATION AND TRANSITION SPANS ON EITHER SIDE OF
TENDER DRAWING THE STATIONS AND DEPOT AT DREAM CITY UNDER SURAT METRO RAIL PROJECT- PHASE -1

This Drawings/Design are property of GMRC. The Drawings/Design VIADUCT STRUCTURE DRAWINGS : NOTES : EMPLOYER : PROOF CHECK CONSULTANT DETAIL DESIGN CONSULTANT (DDC) CONTRACT ID : GMRC/DDC/ELEV-VDCT-STNS & DEPOT/CORRIDOR-1/PH-1, Dated 09-04-2019
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE
cannot be issued by any other person, firm, authority or used by SPECIFIED.
GUJARAT METRO RAIL CORPORATION (GMRC) DRAWING NAME/TITLE : SIZE :
consultant for any other purpose/project without prior written 2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED. LIMITED BLOCK-1, FIRST FLOOR, KARMYOGI ELEVATED VIADUCT
3. ANY DISCREPANCIES MUST BE BROUGHT TO THE NOTICE OF THE CONSULTANT BEFORE BHAVAN,BEHIND NIRMAN BHAWAN, SECTOR-10A
permission of GMRC. The consultant shall indemnify GMRC against A1
EXECUTION OF THE WORK AT SITE. GANDHINAGAR - 382010 SPECIAL STEEL STRUCTURE (60.0M SPAN)
all claims arisen due to infringement of any right protected by design, 4. ANY DEVIATION FROM APPROVED LAND PLANS TO BE BROUGHT TO THE NOTICE OF THE
INDIA
copyright or other intellectual property rights. CONSULTANT BEFORE EXECUTION. LKT ENGINEERING CONSULTANTS LTD SYSTRA MVA CONSULTING (INDIA) PVT. LTD. GENERAL ARRANGEMENT DRAWING
5. ANY DEVIATION FROM BOQ DESCRIPTION AND QUANTITY TO BE BROUGHT TO THE NOTICE OF
THE CONSULTANT BEFORE EXECUTION. LOCATION:
6. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURE, THE DESIGN AND DRAWINGS AS CERTIFIED Vatika Mindscapers, Tower-B, 12/3 Floor 9th, 10th
ISSUED FOR AND SUBMITTED BY THE DETAILED DESIGNER & 11th, Mathura Road, NH-2, Sector-27/D, SHEET NO. 1 OF 2
STRUCTURAL, PLUMBING & FIRE FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWING NO : DDCSMP1-TD-ELV-ST-DW-04485
DRAWINGS. CONSULTANT HAVE BEEN PROOF CHECKED Faridabad, Haryana-121013 REV NO. A0
CONCEPT DRAWING TENDER DRAWING LEGENDS : ABBREVIATIONS : 7. MINIMUM CLEAR COVER SHALL BE : BY M/S LKT AND RECOMMENDED TO MEGA
SCALE :
TYPE OF STRUCTURE EXTREME SEVERE MODERATE
DGM Sr.DGM DGM/ DGM/ FOR APPROVAL. THE DESIGN COMPLIES WITH DATE : 10/06/2020
PRELIMINARY DRAWING FINAL DRAWING(GAD) ENVIRONMENT ENVIRONMENT ENVIRONMENT (Lift & Escalator) (SINGALLING) MANAGER MANAGER MANAGER JGM DBR AND ALL RELEVANT CODAL PROVISIONS. THE RESPONSIBILITY OF CONTROL, IT IS CERTIFIED THAT DETAILED DESIGN PREPARED IS COMPLIED WITH THE TERM AND CONDITION OF CONTRACT AND DBR
FIRST SUBMISSION GFC (MM) (MM) (MM) (SYS) DESIGN ARCH (ARCH) CHECK AND VERIFICATION OF ACCURACY PROVISIONS. DDC OWN FULL RESPONSIBILITY FOR DESIGN ADEQUACY AND MEETING FUNCTIONAL, PERFORMANCE AND
SLAB 50 35 25 NO OBJECTION CORRECTNESS, COMPLETENESS, OPERATIONAL REQUIREMENT INCLUDING CONSIDERATION FOR INTERFACE REQUIREMENT OF OTHER CONCERNED
A1(594x841mm +2mm)

BEAM/GIRDER 60 50 35 INTEGRATION AND FULL COMPLIANCE DESIGNER/CONTRACTOR AND COMPLIANCE TO STANDARDS, NORMS, SAFETY AND STATUARY RULES & REGULATIONS.
REFERENCE DESIGN DOCUMENT : REVISION AND RESUBMISSION REQUIRED
OF CONTRACT PROVISIONS IN RESPECT
PIER/COLUMN 75 75 50
FOUNDATION (PILE/PILE CAP) 75 75 50 OF DESIGN ANALYSIS AND DRAWING RESTS
REFERENCE DRAWING : CLEAR COVER IS THE LEAST DISTANCE FROM OUTER MOST SURFACE OF STEEL OR BINDING GM(Telecom) GM(Traction) CGM(S&T) CGM(SYM) CGM(P&D) WITH THE DDC
WIRE TO FACE OF THE CONCRETE. MV PB PJ DA SV
Sign : Sign : CHECKED BY INTERFACE ENGG. DESIGNED BY CHECKED BY APPROVED BY ISSUED BY

FILE NAME: L:\SYSTRA_INDIA\CAD_PROJECTS\IN01T19A09 - SURAT DDC PHASE 1\04S\WORKDIR\04S485_X.DWG


3800

700 1975 1900 1900 1975 700

TRACK AXIS

TRACK AXIS
3800

700 1975 1900 1900 1975 700

TRACK AXIS

TRACK AXIS
950 1920 1510 2290 1510 1920 950
1200

1200
SECTION B-B
2100

2100
SCALE : 1/50
172 728

172 728
2200 3000

GROUND LVL GROUND LVL


MIN.

MIN.
500

500
KICKER LEVEL KICKER LEVEL

SECTION A-A TRANSVERSE VIEW


SCALE : 1/50
SCALE : 1/50
11500
700 10100 700

2000

N
CL OF BRG.

650
1100

12
NAL
11 NI MAJURA GATE
CH:12313.8
KADARSHA
CH:11721.7

ROOPALI13
CANAL
CH:13611.5

KADARSHA DREAM
L OF PIER CAP

STEEL BRIDGE
ALTHAN 14
TENAMENT
CH:14696.2

NI NAL CITY
15
ALTHAN
CH: 15843.5
GAM

16
VIP
CH: ROAD
16699.1

20 CITY
DREAM
STN.
C/L OF
1400

CH: 20710.3

SURAT 17
WOMEN
CH:
17808.4 ITI

STN.
CENTRE
19
OF CONVENTION
LOCATION CH:
SHIFTED

18
BHIMRAD
CH: 18659.5
1000

KEY PLAN
4200

CL OF BRG.
C

STANDARD BOX GIRDER


850

NOTE:
THIS DRAWING IS BASED ON STRAIGHT ALIGNMENT. HOWEVER IT MAY BE CHANGED
1250

ACCORDING TO SITE SURVEY AND MODIFICATION IN ALIGNMENT IN DETAIL DESIGN.

A0 First Issue MK PJ DA 10/06/2020


4450 2600 4450 REV. PARTICULARS DRN. CHD. VER. DATE
11500 PROJECT NAME :
NOTES : DETAILED DESIGN CONSULTANCY SERVICES FOR CORRIDOR -1 FROM KADARSHA NI NAL (11721.7)
PIER CAP PLAN VIEW 1. FOR GENERAL NOTES PLEASE REFER DRAWING NO. DDCSMP1-TD-ELV-ST-DW-04402 & 04403.
TO DREAM CITY (21610.3) ELEVATED VIADUCT & ELEVATED METRO-RAIL STATIONS - (10 NOS.)
INCLUDING VIADUCT PORTION WITHIN THE STATION AND TRANSITION SPANS ON EITHER SIDE OF
SCALE : 1/50 2. ALL DIMENSIONS ARE TENTATIVE & LIKELY TO CHANGE DURING DETAIL DESIGN.
TENDER DRAWING THE STATIONS AND DEPOT AT DREAM CITY UNDER SURAT METRO RAIL PROJECT- PHASE -1

This Drawings/Design are property of GMRC. The Drawings/Design VIADUCT STRUCTURE DRAWINGS : NOTES : EMPLOYER : PROOF CHECK CONSULTANT DETAIL DESIGN CONSULTANT (DDC) CONTRACT ID : GMRC/DDC/ELEV-VDCT-STNS & DEPOT/CORRIDOR-1/PH-1, Dated 09-04-2019
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE
cannot be issued by any other person, firm, authority or used by SPECIFIED.
GUJARAT METRO RAIL CORPORATION (GMRC) DRAWING NAME/TITLE : SIZE :
consultant for any other purpose/project without prior written 2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED. LIMITED BLOCK-1, FIRST FLOOR, KARMYOGI ELEVATED VIADUCT
3. ANY DISCREPANCIES MUST BE BROUGHT TO THE NOTICE OF THE CONSULTANT BEFORE BHAVAN,BEHIND NIRMAN BHAWAN, SECTOR-10A
permission of GMRC. The consultant shall indemnify GMRC against A1
EXECUTION OF THE WORK AT SITE. GANDHINAGAR - 382010 SPECIAL STEEL STRUCTURE (60.0M SPAN)
all claims arisen due to infringement of any right protected by design, 4. ANY DEVIATION FROM APPROVED LAND PLANS TO BE BROUGHT TO THE NOTICE OF THE
INDIA
copyright or other intellectual property rights. CONSULTANT BEFORE EXECUTION. LKT ENGINEERING CONSULTANTS LTD SYSTRA MVA CONSULTING (INDIA) PVT. LTD. GENERAL ARRANGEMENT DRAWING
5. ANY DEVIATION FROM BOQ DESCRIPTION AND QUANTITY TO BE BROUGHT TO THE NOTICE OF
THE CONSULTANT BEFORE EXECUTION. LOCATION:
6. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURE, THE DESIGN AND DRAWINGS AS CERTIFIED Vatika Mindscapers, Tower-B, 12/3 Floor 9th, 10th
ISSUED FOR AND SUBMITTED BY THE DETAILED DESIGNER & 11th, Mathura Road, NH-2, Sector-27/D, SHEET NO. 2 OF 2
STRUCTURAL, PLUMBING & FIRE FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWING NO : DDCSMP1-TD-ELV-ST-DW-04486
DRAWINGS. CONSULTANT HAVE BEEN PROOF CHECKED Faridabad, Haryana-121013 REV NO. A0
CONCEPT DRAWING TENDER DRAWING LEGENDS : ABBREVIATIONS : 7. MINIMUM CLEAR COVER SHALL BE : BY M/S LKT AND RECOMMENDED TO MEGA
SCALE :
TYPE OF STRUCTURE EXTREME SEVERE MODERATE
DGM Sr.DGM DGM/ DGM/ FOR APPROVAL. THE DESIGN COMPLIES WITH DATE : 10/06/2020
PRELIMINARY DRAWING FINAL DRAWING(GAD) ENVIRONMENT ENVIRONMENT ENVIRONMENT (Lift & Escalator) (SINGALLING) MANAGER MANAGER MANAGER JGM DBR AND ALL RELEVANT CODAL PROVISIONS. THE RESPONSIBILITY OF CONTROL, IT IS CERTIFIED THAT DETAILED DESIGN PREPARED IS COMPLIED WITH THE TERM AND CONDITION OF CONTRACT AND DBR
FIRST SUBMISSION GFC (MM) (MM) (MM) (SYS) DESIGN ARCH (ARCH) CHECK AND VERIFICATION OF ACCURACY PROVISIONS. DDC OWN FULL RESPONSIBILITY FOR DESIGN ADEQUACY AND MEETING FUNCTIONAL, PERFORMANCE AND
SLAB 50 35 25 NO OBJECTION CORRECTNESS, COMPLETENESS, OPERATIONAL REQUIREMENT INCLUDING CONSIDERATION FOR INTERFACE REQUIREMENT OF OTHER CONCERNED
A1(594x841mm +2mm)

BEAM/GIRDER 60 50 35 INTEGRATION AND FULL COMPLIANCE DESIGNER/CONTRACTOR AND COMPLIANCE TO STANDARDS, NORMS, SAFETY AND STATUARY RULES & REGULATIONS.
REFERENCE DESIGN DOCUMENT : REVISION AND RESUBMISSION REQUIRED
OF CONTRACT PROVISIONS IN RESPECT
PIER/COLUMN 75 75 50
FOUNDATION (PILE/PILE CAP) 75 75 50 OF DESIGN ANALYSIS AND DRAWING RESTS
REFERENCE DRAWING : CLEAR COVER IS THE LEAST DISTANCE FROM OUTER MOST SURFACE OF STEEL OR BINDING GM(Telecom) GM(Traction) CGM(S&T) CGM(SYM) CGM(P&D) WITH THE DDC
WIRE TO FACE OF THE CONCRETE. MV PB PJ DA SV
Sign : Sign : CHECKED BY INTERFACE ENGG. DESIGNED BY CHECKED BY APPROVED BY ISSUED BY

FILE NAME: L:\SYSTRA_INDIA\CAD_PROJECTS\IN01T19A09 - SURAT DDC PHASE 1\04S\WORKDIR\04S486_X.DWG


TO SARTHANA TO DREAM CITY
STAGE 1
ASSEMBLE THE STEEL TRUSS SEGMENT WISE OVER STEEL TRESTLES BETWEEN PIER PP2-03-PP2-05.

PP2-03 PP2-04 PP2-05


TP2-01 P2-02 LAUNCHING DIRECTION

FLYOVER

T8 T7 T6 T5 T4 T3 T2 T1

8000
28000 60000 28000 28000

TO SARTHANA TO DREAM CITY


STAGE 2
ASSEMBLE TRESTLE T9 AND T10 AT REQUIRED LOCATION
FIX THE ROLLER ON TRESTLES.
FIX THE WINCH MACHINE.
PP2-03 PP2-04 PP2-05
TP2-01 P2-02 LAUNCHING DIRECTION

FLYOVER

T10 T9 T8 T7 T6 T5 T4 T3 T2 T1
ELECTRIC
WINCH
20000 9000 8000
28000 60000 28000 28000

TO SARTHANA TO DREAM CITY


STAGE 3
START THE PULLING OF TRUSS WITH THE HELP OF WINCH TILL IT REACHES T9 TRESTLE AND REMOVE TRESTLE T1, T2 & T8.

PP2-03 PP2-04 PP2-05


TP2-01 P2-02 LAUNCHING DIRECTION

FLYOVER

T10 T9 T7 T6 T5 T4 T3
ELECTRIC
20000 17000 WINCH
28000 60000 28000 28000

NOTES:
1. THE TRESTLE POSITION EXCEPT T8, T9, T10 & T11 ARE INDICATIVE ONLY AND SHALL
N

NI NAL
12
MAJURA GATE

BE PLACED AS PER SEGMENT ASSEMBLY REQUIREMENT & GROUND FEASIBILITY NOTES :


11

CH:12313.8
KADARSHA
CH:11721.7

13
ROOPALI
CANAL
CH:13611.5

A0 First Issue MK PJ DA 10/06/2020


KADARSHA ALTHAN
14
CH:14696.2
TENAMENT

DREAM KEEPING SPACING BETWEEN TRESTLES NOT MORE THAN 10.0M. 1. FOR GENERAL NOTES PLEASE REFER DRAWING NO. DDCSMP1-TD-ELV-ST-DW-04402 & 04403.
2. ALL DIMENSIONS ARE TENTATIVE & LIKELY TO CHANGE DURING DETAIL DESIGN. REV. PARTICULARS DRN. CHD. VER. DATE
NI NAL CITY 2. TRESTLE T9 & T10 SHALL BE PLACED AS CLOSE AS POSSIBLE AT SITE IN VIEW OF
ALTHAN
15
GAM
CH:
15843.5

16

PROJECT NAME :
VIP
CH: ROAD
16699.1

CLEAR WORKING SPACE FROM EXISTING FLYOVER. ALSO TRESTLE T8 & T11 SHALL
20 CITY
DREAM
STN. 20710.3
C/L OF CH:

17
SURAT
WOMEN
CH:
17808.4 ITI

STN.
CENTRE

DETAILED DESIGN CONSULTANCY SERVICES FOR CORRIDOR -1 FROM KADARSHA NI NAL (11721.7)
19
OF CONVENTION
LOCATION CH:
SHIFTED

BE PLACED ACCORDING TO T9 & T10 RESPECTIVELY KEEPING IN VIEW OF SMOOTH


18
BHIMRAD
18659.5
CH:

TO DREAM CITY (21610.3) ELEVATED VIADUCT & ELEVATED METRO-RAIL STATIONS - (10 NOS.)
KEY PLAN TRAFFIC MOVEMENT & MINIMUM CANTILEVER EFFECT DURING LAUNCHING. INCLUDING VIADUCT PORTION WITHIN THE STATION AND TRANSITION SPANS ON EITHER SIDE OF
TENDER DRAWING THE STATIONS AND DEPOT AT DREAM CITY UNDER SURAT METRO RAIL PROJECT- PHASE -1

This Drawings/Design are property of GMRC. The Drawings/Design VIADUCT STRUCTURE DRAWINGS : NOTES : EMPLOYER : PROOF CHECK CONSULTANT DETAIL DESIGN CONSULTANT (DDC) CONTRACT ID : GMRC/DDC/ELEV-VDCT-STNS & DEPOT/CORRIDOR-1/PH-1, Dated 09-04-2019
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE
cannot be issued by any other person, firm, authority or used by SPECIFIED.
GUJARAT METRO RAIL CORPORATION (GMRC) DRAWING NAME/TITLE : SIZE :
consultant for any other purpose/project without prior written 2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED. LIMITED BLOCK-1, FIRST FLOOR, KARMYOGI ELEVATED VIADUCT
3. ANY DISCREPANCIES MUST BE BROUGHT TO THE NOTICE OF THE CONSULTANT BEFORE BHAVAN,BEHIND NIRMAN BHAWAN, SECTOR-10A
permission of GMRC. The consultant shall indemnify GMRC against A1
EXECUTION OF THE WORK AT SITE. GANDHINAGAR - 382010 SPECIAL STEEL STRUCTURE
all claims arisen due to infringement of any right protected by design, 4. ANY DEVIATION FROM APPROVED LAND PLANS TO BE BROUGHT TO THE NOTICE OF THE
INDIA
copyright or other intellectual property rights. CONSULTANT BEFORE EXECUTION. LKT ENGINEERING CONSULTANTS LTD SYSTRA MVA CONSULTING (INDIA) PVT. LTD. LAUNCHING SCHEME
5. ANY DEVIATION FROM BOQ DESCRIPTION AND QUANTITY TO BE BROUGHT TO THE NOTICE OF
THE CONSULTANT BEFORE EXECUTION. LOCATION:
6. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURE, THE DESIGN AND DRAWINGS AS CERTIFIED Vatika Mindscapers, Tower-B, 12/3 Floor 9th, 10th
ISSUED FOR AND SUBMITTED BY THE DETAILED DESIGNER & 11th, Mathura Road, NH-2, Sector-27/D, SHEET NO. 1 OF 3
STRUCTURAL, PLUMBING & FIRE FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWING NO : DDCSMP1-TD-ELV-ST-DW-04487
DRAWINGS. CONSULTANT HAVE BEEN PROOF CHECKED Faridabad, Haryana-121013 REV NO. A0
CONCEPT DRAWING TENDER DRAWING LEGENDS : ABBREVIATIONS : 7. MINIMUM CLEAR COVER SHALL BE : BY M/S LKT AND RECOMMENDED TO MEGA
SCALE :
TYPE OF STRUCTURE EXTREME SEVERE MODERATE
DGM Sr.DGM DGM/ DGM/ FOR APPROVAL. THE DESIGN COMPLIES WITH DATE : 10/06/2020
PRELIMINARY DRAWING FINAL DRAWING(GAD) ENVIRONMENT ENVIRONMENT ENVIRONMENT (Lift & Escalator) (SINGALLING) MANAGER MANAGER MANAGER JGM DBR AND ALL RELEVANT CODAL PROVISIONS. THE RESPONSIBILITY OF CONTROL, IT IS CERTIFIED THAT DETAILED DESIGN PREPARED IS COMPLIED WITH THE TERM AND CONDITION OF CONTRACT AND DBR
FIRST SUBMISSION GFC (MM) (MM) (MM) (SYS) DESIGN ARCH (ARCH) CHECK AND VERIFICATION OF ACCURACY PROVISIONS. DDC OWN FULL RESPONSIBILITY FOR DESIGN ADEQUACY AND MEETING FUNCTIONAL, PERFORMANCE AND
SLAB 50 35 25 NO OBJECTION CORRECTNESS, COMPLETENESS, OPERATIONAL REQUIREMENT INCLUDING CONSIDERATION FOR INTERFACE REQUIREMENT OF OTHER CONCERNED
A1(594x841mm +2mm)

BEAM/GIRDER 60 50 35 INTEGRATION AND FULL COMPLIANCE DESIGNER/CONTRACTOR AND COMPLIANCE TO STANDARDS, NORMS, SAFETY AND STATUARY RULES & REGULATIONS.
REFERENCE DESIGN DOCUMENT : REVISION AND RESUBMISSION REQUIRED
OF CONTRACT PROVISIONS IN RESPECT
PIER/COLUMN 75 75 50
FOUNDATION (PILE/PILE CAP) 75 75 50 OF DESIGN ANALYSIS AND DRAWING RESTS
REFERENCE DRAWING : CLEAR COVER IS THE LEAST DISTANCE FROM OUTER MOST SURFACE OF STEEL OR BINDING GM(Telecom) GM(Traction) CGM(S&T) CGM(SYM) CGM(P&D) WITH THE DDC
WIRE TO FACE OF THE CONCRETE. MV PB PJ DA SV
Sign : Sign : CHECKED BY INTERFACE ENGG. DESIGNED BY CHECKED BY APPROVED BY ISSUED BY

FILE NAME: L:\SYSTRA_INDIA\CAD_PROJECTS\IN01T19A09 - SURAT DDC PHASE 1\04S\WORKDIR\04S487_X.DWG


TO SARTHANA TO DREAM CITY
STAGE 4
CONTINUE THE PULLING OF TRUSS WITH THE HELP OF WINCH TILL IT REACHES T10 TRESTLE AND REMOVE TRESTLE T3 & T4.
ASSEMBLE TRESTLE T11 AT REQUIRED LOCATION AND FIX THE ROLLER OVER IT.
PP2-03 PP2-04 PP2-05
TP2-01 P2-02 LAUNCHING DIRECTION

FLYOVER

T11 T10 T9 T7 T6 T5
ELECTRIC
11000 20000 17000 WINCH

28000 60000 28000 28000

TO SARTHANA TO DREAM CITY


STAGE 5
CONTINUE THE PULLING OF TRUSS WITH THE HELP OF WINCH TILL IT REACHES T11 TRESTLE AND REMOVE TRESTLE T5 & T6.

PP2-03 PP2-04 PP2-05


TP2-01 P2-02 LAUNCHING DIRECTION

FLYOVER

T11 T10 T9 T7
ELECTRIC
11000 20000 17000 WINCH

28000 60000 28000 28000


N

NI NAL
12
MAJURA GATE
NOTES :
11

CH:12313.8
KADARSHA
CH:11721.7

13
ROOPALI
CANAL
CH:13611.5

A0 First Issue MK PJ DA 10/06/2020


KADARSHA ALTHAN
14
CH:14696.2
TENAMENT

DREAM 1. FOR GENERAL NOTES PLEASE REFER DRAWING NO. DDCSMP1-TD-ELV-ST-DW-04402 & 04403.
2. ALL DIMENSIONS ARE TENTATIVE & LIKELY TO CHANGE DURING DETAIL DESIGN. REV. PARTICULARS DRN. CHD. VER. DATE
NI NAL CITY
ALTHAN
15
GAM
CH:
15843.5

16

PROJECT NAME :
VIP
CH: ROAD
16699.1

20 CITY
DREAM
STN. 20710.3
C/L OF CH:

17
SURAT
WOMEN
CH:
17808.4 ITI

STN.
CENTRE

DETAILED DESIGN CONSULTANCY SERVICES FOR CORRIDOR -1 FROM KADARSHA NI NAL (11721.7)
19
OF CONVENTION
LOCATION CH:
SHIFTED

18
BHIMRAD
18659.5
CH:

TO DREAM CITY (21610.3) ELEVATED VIADUCT & ELEVATED METRO-RAIL STATIONS - (10 NOS.)
KEY PLAN INCLUDING VIADUCT PORTION WITHIN THE STATION AND TRANSITION SPANS ON EITHER SIDE OF
TENDER DRAWING THE STATIONS AND DEPOT AT DREAM CITY UNDER SURAT METRO RAIL PROJECT- PHASE -1

This Drawings/Design are property of GMRC. The Drawings/Design VIADUCT STRUCTURE DRAWINGS : NOTES : EMPLOYER : PROOF CHECK CONSULTANT DETAIL DESIGN CONSULTANT (DDC) CONTRACT ID : GMRC/DDC/ELEV-VDCT-STNS & DEPOT/CORRIDOR-1/PH-1, Dated 09-04-2019
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE
cannot be issued by any other person, firm, authority or used by SPECIFIED.
GUJARAT METRO RAIL CORPORATION (GMRC) DRAWING NAME/TITLE : SIZE :
consultant for any other purpose/project without prior written 2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED. LIMITED BLOCK-1, FIRST FLOOR, KARMYOGI ELEVATED VIADUCT
3. ANY DISCREPANCIES MUST BE BROUGHT TO THE NOTICE OF THE CONSULTANT BEFORE BHAVAN,BEHIND NIRMAN BHAWAN, SECTOR-10A
permission of GMRC. The consultant shall indemnify GMRC against A1
EXECUTION OF THE WORK AT SITE. GANDHINAGAR - 382010 SPECIAL STEEL STRUCTURE
all claims arisen due to infringement of any right protected by design, 4. ANY DEVIATION FROM APPROVED LAND PLANS TO BE BROUGHT TO THE NOTICE OF THE
INDIA
copyright or other intellectual property rights. CONSULTANT BEFORE EXECUTION. LKT ENGINEERING CONSULTANTS LTD SYSTRA MVA CONSULTING (INDIA) PVT. LTD. LAUNCHING SCHEME
5. ANY DEVIATION FROM BOQ DESCRIPTION AND QUANTITY TO BE BROUGHT TO THE NOTICE OF
THE CONSULTANT BEFORE EXECUTION. LOCATION:
6. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURE, THE DESIGN AND DRAWINGS AS CERTIFIED Vatika Mindscapers, Tower-B, 12/3 Floor 9th, 10th
ISSUED FOR AND SUBMITTED BY THE DETAILED DESIGNER & 11th, Mathura Road, NH-2, Sector-27/D, SHEET NO. 2 OF 3
STRUCTURAL, PLUMBING & FIRE FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWING NO : DDCSMP1-TD-ELV-ST-DW-04488
DRAWINGS. CONSULTANT HAVE BEEN PROOF CHECKED Faridabad, Haryana-121013 REV NO. A0
CONCEPT DRAWING TENDER DRAWING LEGENDS : ABBREVIATIONS : 7. MINIMUM CLEAR COVER SHALL BE : BY M/S LKT AND RECOMMENDED TO MEGA
SCALE :
TYPE OF STRUCTURE EXTREME SEVERE MODERATE
DGM Sr.DGM DGM/ DGM/ FOR APPROVAL. THE DESIGN COMPLIES WITH DATE : 10/06/2020
PRELIMINARY DRAWING FINAL DRAWING(GAD) ENVIRONMENT ENVIRONMENT ENVIRONMENT (Lift & Escalator) (SINGALLING) MANAGER MANAGER MANAGER JGM DBR AND ALL RELEVANT CODAL PROVISIONS. THE RESPONSIBILITY OF CONTROL, IT IS CERTIFIED THAT DETAILED DESIGN PREPARED IS COMPLIED WITH THE TERM AND CONDITION OF CONTRACT AND DBR
FIRST SUBMISSION GFC (MM) (MM) (MM) (SYS) DESIGN ARCH (ARCH) CHECK AND VERIFICATION OF ACCURACY PROVISIONS. DDC OWN FULL RESPONSIBILITY FOR DESIGN ADEQUACY AND MEETING FUNCTIONAL, PERFORMANCE AND
SLAB 50 35 25 NO OBJECTION CORRECTNESS, COMPLETENESS, OPERATIONAL REQUIREMENT INCLUDING CONSIDERATION FOR INTERFACE REQUIREMENT OF OTHER CONCERNED
A1(594x841mm +2mm)

BEAM/GIRDER 60 50 35 INTEGRATION AND FULL COMPLIANCE DESIGNER/CONTRACTOR AND COMPLIANCE TO STANDARDS, NORMS, SAFETY AND STATUARY RULES & REGULATIONS.
REFERENCE DESIGN DOCUMENT : REVISION AND RESUBMISSION REQUIRED
OF CONTRACT PROVISIONS IN RESPECT
PIER/COLUMN 75 75 50
FOUNDATION (PILE/PILE CAP) 75 75 50 OF DESIGN ANALYSIS AND DRAWING RESTS
REFERENCE DRAWING : CLEAR COVER IS THE LEAST DISTANCE FROM OUTER MOST SURFACE OF STEEL OR BINDING GM(Telecom) GM(Traction) CGM(S&T) CGM(SYM) CGM(P&D) WITH THE DDC
WIRE TO FACE OF THE CONCRETE. MV PB PJ DA SV
Sign : Sign : CHECKED BY INTERFACE ENGG. DESIGNED BY CHECKED BY APPROVED BY ISSUED BY

FILE NAME: L:\SYSTRA_INDIA\CAD_PROJECTS\IN01T19A09 - SURAT DDC PHASE 1\04S\WORKDIR\04S488_X.DWG


TO SARTHANA TO DREAM CITY
STAGE 6
CONTINUE THE PULLING OF TRUSS WITH THE HELP OF WINCH TILL IT REACHES PIER P2-02 AND REMOVE TRESTLE T7 & T11.

PP2-03 PP2-04 PP2-05


TP2-01 P2-02 LAUNCHING DIRECTION

FLYOVER

T10 T9
ELECTRIC
23000 20000 17000 WINCH

28000 60000 28000 28000

TO SARTHANA TO DREAM CITY


STAGE 7
LOWERING THE SPAN ON PIER BEARING WITH THE HELP OF JACKS AND ERECT ADJACENT SPANS.

PP2-03 PP2-04 PP2-05


TP2-01 P2-02 LAUNCHING DIRECTION

FLYOVER
N

NI NAL
12
MAJURA GATE
NOTES :
11

CH:12313.8
KADARSHA
CH:11721.7

13
ROOPALI
CANAL
CH:13611.5

A0 First Issue MK PJ DA 10/06/2020


KADARSHA ALTHAN
14
CH:14696.2
TENAMENT

DREAM 1. FOR GENERAL NOTES PLEASE REFER DRAWING NO. DDCSMP1-TD-ELV-ST-DW-04402 & 04403.
2. ALL DIMENSIONS ARE TENTATIVE & LIKELY TO CHANGE DURING DETAIL DESIGN. REV. PARTICULARS DRN. CHD. VER. DATE
NI NAL CITY
ALTHAN
15
GAM
CH:
15843.5

16

PROJECT NAME :
VIP
CH: ROAD
16699.1

20 CITY
DREAM
STN. 20710.3
C/L OF CH:

17
SURAT
WOMEN
CH:
17808.4 ITI

STN.
CENTRE

DETAILED DESIGN CONSULTANCY SERVICES FOR CORRIDOR -1 FROM KADARSHA NI NAL (11721.7)
19
OF CONVENTION
LOCATION CH:
SHIFTED

18
BHIMRAD
18659.5
CH:

TO DREAM CITY (21610.3) ELEVATED VIADUCT & ELEVATED METRO-RAIL STATIONS - (10 NOS.)
KEY PLAN INCLUDING VIADUCT PORTION WITHIN THE STATION AND TRANSITION SPANS ON EITHER SIDE OF
TENDER DRAWING THE STATIONS AND DEPOT AT DREAM CITY UNDER SURAT METRO RAIL PROJECT- PHASE -1

This Drawings/Design are property of GMRC. The Drawings/Design VIADUCT STRUCTURE DRAWINGS : NOTES : EMPLOYER : PROOF CHECK CONSULTANT DETAIL DESIGN CONSULTANT (DDC) CONTRACT ID : GMRC/DDC/ELEV-VDCT-STNS & DEPOT/CORRIDOR-1/PH-1, Dated 09-04-2019
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE
cannot be issued by any other person, firm, authority or used by SPECIFIED.
GUJARAT METRO RAIL CORPORATION (GMRC) DRAWING NAME/TITLE : SIZE :
consultant for any other purpose/project without prior written 2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED. LIMITED BLOCK-1, FIRST FLOOR, KARMYOGI ELEVATED VIADUCT
3. ANY DISCREPANCIES MUST BE BROUGHT TO THE NOTICE OF THE CONSULTANT BEFORE BHAVAN,BEHIND NIRMAN BHAWAN, SECTOR-10A
permission of GMRC. The consultant shall indemnify GMRC against A1
EXECUTION OF THE WORK AT SITE. GANDHINAGAR - 382010 SPECIAL STEEL STRUCTURE
all claims arisen due to infringement of any right protected by design, 4. ANY DEVIATION FROM APPROVED LAND PLANS TO BE BROUGHT TO THE NOTICE OF THE
INDIA
copyright or other intellectual property rights. CONSULTANT BEFORE EXECUTION. LKT ENGINEERING CONSULTANTS LTD SYSTRA MVA CONSULTING (INDIA) PVT. LTD. LAUNCHING SCHEME
5. ANY DEVIATION FROM BOQ DESCRIPTION AND QUANTITY TO BE BROUGHT TO THE NOTICE OF
THE CONSULTANT BEFORE EXECUTION. LOCATION:
6. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURE, THE DESIGN AND DRAWINGS AS CERTIFIED Vatika Mindscapers, Tower-B, 12/3 Floor 9th, 10th
ISSUED FOR AND SUBMITTED BY THE DETAILED DESIGNER & 11th, Mathura Road, NH-2, Sector-27/D, SHEET NO. 3 OF 3
STRUCTURAL, PLUMBING & FIRE FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWING NO : DDCSMP1-TD-ELV-ST-DW-04489
DRAWINGS. CONSULTANT HAVE BEEN PROOF CHECKED Faridabad, Haryana-121013 REV NO. A0
CONCEPT DRAWING TENDER DRAWING LEGENDS : ABBREVIATIONS : 7. MINIMUM CLEAR COVER SHALL BE : BY M/S LKT AND RECOMMENDED TO MEGA
SCALE :
TYPE OF STRUCTURE EXTREME SEVERE MODERATE
DGM Sr.DGM DGM/ DGM/ FOR APPROVAL. THE DESIGN COMPLIES WITH DATE : 10/06/2020
PRELIMINARY DRAWING FINAL DRAWING(GAD) ENVIRONMENT ENVIRONMENT ENVIRONMENT (Lift & Escalator) (SINGALLING) MANAGER MANAGER MANAGER JGM DBR AND ALL RELEVANT CODAL PROVISIONS. THE RESPONSIBILITY OF CONTROL, IT IS CERTIFIED THAT DETAILED DESIGN PREPARED IS COMPLIED WITH THE TERM AND CONDITION OF CONTRACT AND DBR
FIRST SUBMISSION GFC (MM) (MM) (MM) (SYS) DESIGN ARCH (ARCH) CHECK AND VERIFICATION OF ACCURACY PROVISIONS. DDC OWN FULL RESPONSIBILITY FOR DESIGN ADEQUACY AND MEETING FUNCTIONAL, PERFORMANCE AND
SLAB 50 35 25 NO OBJECTION CORRECTNESS, COMPLETENESS, OPERATIONAL REQUIREMENT INCLUDING CONSIDERATION FOR INTERFACE REQUIREMENT OF OTHER CONCERNED
A1(594x841mm +2mm)

BEAM/GIRDER 60 50 35 INTEGRATION AND FULL COMPLIANCE DESIGNER/CONTRACTOR AND COMPLIANCE TO STANDARDS, NORMS, SAFETY AND STATUARY RULES & REGULATIONS.
REFERENCE DESIGN DOCUMENT : REVISION AND RESUBMISSION REQUIRED
OF CONTRACT PROVISIONS IN RESPECT
PIER/COLUMN 75 75 50
FOUNDATION (PILE/PILE CAP) 75 75 50 OF DESIGN ANALYSIS AND DRAWING RESTS
REFERENCE DRAWING : CLEAR COVER IS THE LEAST DISTANCE FROM OUTER MOST SURFACE OF STEEL OR BINDING GM(Telecom) GM(Traction) CGM(S&T) CGM(SYM) CGM(P&D) WITH THE DDC
WIRE TO FACE OF THE CONCRETE. MV PB PJ DA SV
Sign : Sign : CHECKED BY INTERFACE ENGG. DESIGNED BY CHECKED BY APPROVED BY ISSUED BY

FILE NAME: L:\SYSTRA_INDIA\CAD_PROJECTS\IN01T19A09 - SURAT DDC PHASE 1\04S\WORKDIR\04S489_X.DWG


B
-

70000

A A
- -

PP3-32 P3-33

8000
RAIL LVL

1000 4000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 4000 1000

B
-

LONGITUDINAL ELEVATION
SCALE : 1/100

GROUND LVL GROUND LVL


MIN.

MIN.
500

500
KICKER LEVEL KICKER LEVEL

A
-

PP3-32 P3-33
70000
500
1000

TRACK AXIS

1900
10100
9100

3800
C OF PIER /
L
ALIGNMENT

1900
TRACK AXIS
1000
500

1000 4000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 4000 1000

PLAN VIEW
SCALE : 1/100
N

12
MAJURA GATE
NI NAL
11

CH:12313.8
KADARSHA
CH:11721.7

13
ROOPALI
CANAL
CH:13611.5

A0 First Issue MK PJ DA 10/06/2020


KADARSHA ALTHAN
14
CH:14696.2
TENAMENT

DREAM
REV. PARTICULARS DRN. CHD. VER. DATE
NI NAL
ALTHAN
CH:
15
GAM
15843.5

16
CITY NOTES :
PROJECT NAME :
VIP
CH: ROAD
16699.1

20 CITY
DREAM
STN. 20710.3
C/L OF CH:

SURAT
CH:
17
WOMEN
17808.4 ITI

CENTRE
STN.

1. FOR GENERAL NOTES PLEASE REFER DRAWING NO. DDCSMP1-TD-ELV-ST-DW-04402 & 04403.
DETAILED DESIGN CONSULTANCY SERVICES FOR CORRIDOR -1 FROM KADARSHA NI NAL (11721.7)
19
OF CONVENTION
LOCATION CH:
SHIFTED

18
BHIMRAD
18659.5
CH:

2. ALL DIMENSIONS ARE TENTATIVE & LIKELY TO CHANGE DURING DETAIL DESIGN. TO DREAM CITY (21610.3) ELEVATED VIADUCT & ELEVATED METRO-RAIL STATIONS - (10 NOS.)
KEY PLAN INCLUDING VIADUCT PORTION WITHIN THE STATION AND TRANSITION SPANS ON EITHER SIDE OF
TENDER DRAWING THE STATIONS AND DEPOT AT DREAM CITY UNDER SURAT METRO RAIL PROJECT- PHASE -1

This Drawings/Design are property of GMRC. The Drawings/Design VIADUCT STRUCTURE DRAWINGS : NOTES : EMPLOYER : PROOF CHECK CONSULTANT DETAIL DESIGN CONSULTANT (DDC) CONTRACT ID : GMRC/DDC/ELEV-VDCT-STNS & DEPOT/CORRIDOR-1/PH-1, Dated 09-04-2019
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE
cannot be issued by any other person, firm, authority or used by SPECIFIED.
GUJARAT METRO RAIL CORPORATION (GMRC) DRAWING NAME/TITLE : SIZE :
consultant for any other purpose/project without prior written 2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED. LIMITED BLOCK-1, FIRST FLOOR, KARMYOGI ELEVATED VIADUCT
3. ANY DISCREPANCIES MUST BE BROUGHT TO THE NOTICE OF THE CONSULTANT BEFORE BHAVAN,BEHIND NIRMAN BHAWAN, SECTOR-10A
permission of GMRC. The consultant shall indemnify GMRC against A1
EXECUTION OF THE WORK AT SITE. GANDHINAGAR - 382010 SPECIAL STEEL STRUCTURE (70.0M SPAN)
all claims arisen due to infringement of any right protected by design, 4. ANY DEVIATION FROM APPROVED LAND PLANS TO BE BROUGHT TO THE NOTICE OF THE
INDIA
copyright or other intellectual property rights. CONSULTANT BEFORE EXECUTION. LKT ENGINEERING CONSULTANTS LTD SYSTRA MVA CONSULTING (INDIA) PVT. LTD. GENERAL ARRANGEMENT DRAWING
5. ANY DEVIATION FROM BOQ DESCRIPTION AND QUANTITY TO BE BROUGHT TO THE NOTICE OF
THE CONSULTANT BEFORE EXECUTION. LOCATION:
6. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURE, THE DESIGN AND DRAWINGS AS CERTIFIED Vatika Mindscapers, Tower-B, 12/3 Floor 9th, 10th
ISSUED FOR AND SUBMITTED BY THE DETAILED DESIGNER & 11th, Mathura Road, NH-2, Sector-27/D, SHEET NO. 1 OF 2
STRUCTURAL, PLUMBING & FIRE FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWING NO : DDCSMP1-TD-ELV-ST-DW-04490
DRAWINGS. CONSULTANT HAVE BEEN PROOF CHECKED Faridabad, Haryana-121013 REV NO. A0
CONCEPT DRAWING TENDER DRAWING LEGENDS : ABBREVIATIONS : 7. MINIMUM CLEAR COVER SHALL BE : BY M/S LKT AND RECOMMENDED TO MEGA
SCALE :
TYPE OF STRUCTURE EXTREME SEVERE MODERATE
DGM Sr.DGM DGM/ DGM/ FOR APPROVAL. THE DESIGN COMPLIES WITH DATE : 10/06/2020
PRELIMINARY DRAWING FINAL DRAWING(GAD) ENVIRONMENT ENVIRONMENT ENVIRONMENT (Lift & Escalator) (SINGALLING) MANAGER MANAGER MANAGER JGM DBR AND ALL RELEVANT CODAL PROVISIONS. THE RESPONSIBILITY OF CONTROL, IT IS CERTIFIED THAT DETAILED DESIGN PREPARED IS COMPLIED WITH THE TERM AND CONDITION OF CONTRACT AND DBR
FIRST SUBMISSION GFC (MM) (MM) (MM) (SYS) DESIGN ARCH (ARCH) CHECK AND VERIFICATION OF ACCURACY PROVISIONS. DDC OWN FULL RESPONSIBILITY FOR DESIGN ADEQUACY AND MEETING FUNCTIONAL, PERFORMANCE AND
SLAB 50 35 25 NO OBJECTION CORRECTNESS, COMPLETENESS, OPERATIONAL REQUIREMENT INCLUDING CONSIDERATION FOR INTERFACE REQUIREMENT OF OTHER CONCERNED
A1(594x841mm +2mm)

BEAM/GIRDER 60 50 35 INTEGRATION AND FULL COMPLIANCE DESIGNER/CONTRACTOR AND COMPLIANCE TO STANDARDS, NORMS, SAFETY AND STATUARY RULES & REGULATIONS.
REFERENCE DESIGN DOCUMENT : REVISION AND RESUBMISSION REQUIRED
OF CONTRACT PROVISIONS IN RESPECT
PIER/COLUMN 75 75 50
FOUNDATION (PILE/PILE CAP) 75 75 50 OF DESIGN ANALYSIS AND DRAWING RESTS
REFERENCE DRAWING : CLEAR COVER IS THE LEAST DISTANCE FROM OUTER MOST SURFACE OF STEEL OR BINDING GM(Telecom) GM(Traction) CGM(S&T) CGM(SYM) CGM(P&D) WITH THE DDC
WIRE TO FACE OF THE CONCRETE. MV PB PJ DA SV
Sign : Sign : CHECKED BY INTERFACE ENGG. DESIGNED BY CHECKED BY APPROVED BY ISSUED BY

FILE NAME: L:\SYSTRA_INDIA\CAD_PROJECTS\IN01T19A09 - SURAT DDC PHASE 1\04S\WORKDIR\04S490_X.DWG


500 10100 500 500 10100 500
1000 9100 1000 1000 9100 1000

8000
3800 3800
8000

8000
700 1950 1900 1900 1950 700 700 1950 1900 1900 1950 700

ALIGNMENT

ALIGNMENT
C OF PIER /
C OF PIER /

TRACK AXIS

TRACK AXIS
TRACK AXIS

TRACK AXIS
L

L
RAIL LVL

2395 1510 2290 1510 2395


2395 1510 2290 1510 2395
SECTION B-B
SCALE : 1/50

2200 3000

GROUND LVL GROUND LVL

MIN.
MIN.
500

500
KICKER LEVEL KICKER LEVEL

N
12
NAL
11 NI MAJURA GATE
CH:12313.8
KADARSHA
CH:11721.7

ROOPALI13
CANAL
CH:13611.5

KADARSHA ALTHAN 14
TENAMENT
CH:14696.2

DREAM
NI NAL CITY
15
ALTHAN
CH: 15843.5
GAM

16
VIP
CH: ROAD
16699.1

20 CITY
DREAM
STN.
C/L OF
CH: 20710.3

SURAT 17
WOMEN
CH:
17808.4 ITI

STN.
CENTRE
19
OF CONVENTION
LOCATION CH:
SHIFTED

18
BHIMRAD
CH: 18659.5

KEY PLAN

SECTION A-A TRANSVERSE VIEW


SCALE : 1/50
SCALE : 1/50

A0 First Issue MK PJ DA 10/06/2020

REV. PARTICULARS DRN. CHD. VER. DATE


NOTES :
PROJECT NAME :
1. FOR GENERAL NOTES PLEASE REFER DRAWING NO. DDCSMP1-TD-ELV-ST-DW-04402 & 04403.
DETAILED DESIGN CONSULTANCY SERVICES FOR CORRIDOR -1 FROM KADARSHA NI NAL (11721.7)
2. ALL DIMENSIONS ARE TENTATIVE & LIKELY TO CHANGE DURING DETAIL DESIGN. TO DREAM CITY (21610.3) ELEVATED VIADUCT & ELEVATED METRO-RAIL STATIONS - (10 NOS.)
INCLUDING VIADUCT PORTION WITHIN THE STATION AND TRANSITION SPANS ON EITHER SIDE OF
TENDER DRAWING THE STATIONS AND DEPOT AT DREAM CITY UNDER SURAT METRO RAIL PROJECT- PHASE -1

This Drawings/Design are property of GMRC. The Drawings/Design VIADUCT STRUCTURE DRAWINGS : NOTES : EMPLOYER : PROOF CHECK CONSULTANT DETAIL DESIGN CONSULTANT (DDC) CONTRACT ID : GMRC/DDC/ELEV-VDCT-STNS & DEPOT/CORRIDOR-1/PH-1, Dated 09-04-2019
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE
cannot be issued by any other person, firm, authority or used by SPECIFIED.
GUJARAT METRO RAIL CORPORATION (GMRC) DRAWING NAME/TITLE : SIZE :
consultant for any other purpose/project without prior written 2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED. LIMITED BLOCK-1, FIRST FLOOR, KARMYOGI ELEVATED VIADUCT
3. ANY DISCREPANCIES MUST BE BROUGHT TO THE NOTICE OF THE CONSULTANT BEFORE BHAVAN,BEHIND NIRMAN BHAWAN, SECTOR-10A
permission of GMRC. The consultant shall indemnify GMRC against A1
EXECUTION OF THE WORK AT SITE. GANDHINAGAR - 382010 SPECIAL STEEL STRUCTURE (70.0M SPAN)
all claims arisen due to infringement of any right protected by design, 4. ANY DEVIATION FROM APPROVED LAND PLANS TO BE BROUGHT TO THE NOTICE OF THE
INDIA
copyright or other intellectual property rights. CONSULTANT BEFORE EXECUTION. LKT ENGINEERING CONSULTANTS LTD SYSTRA MVA CONSULTING (INDIA) PVT. LTD. GENERAL ARRANGEMENT DRAWING
5. ANY DEVIATION FROM BOQ DESCRIPTION AND QUANTITY TO BE BROUGHT TO THE NOTICE OF
THE CONSULTANT BEFORE EXECUTION. LOCATION:
6. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURE, THE DESIGN AND DRAWINGS AS CERTIFIED Vatika Mindscapers, Tower-B, 12/3 Floor 9th, 10th
ISSUED FOR AND SUBMITTED BY THE DETAILED DESIGNER & 11th, Mathura Road, NH-2, Sector-27/D, SHEET NO. 2 OF 2
STRUCTURAL, PLUMBING & FIRE FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWING NO : DDCSMP1-TD-ELV-ST-DW-04491
DRAWINGS. CONSULTANT HAVE BEEN PROOF CHECKED Faridabad, Haryana-121013 REV NO. A0
CONCEPT DRAWING TENDER DRAWING LEGENDS : ABBREVIATIONS : 7. MINIMUM CLEAR COVER SHALL BE : BY M/S LKT AND RECOMMENDED TO MEGA
SCALE :
TYPE OF STRUCTURE EXTREME SEVERE MODERATE
DGM Sr.DGM DGM/ DGM/ FOR APPROVAL. THE DESIGN COMPLIES WITH DATE : 10/06/2020
PRELIMINARY DRAWING FINAL DRAWING(GAD) ENVIRONMENT ENVIRONMENT ENVIRONMENT (Lift & Escalator) (SINGALLING) MANAGER MANAGER MANAGER JGM DBR AND ALL RELEVANT CODAL PROVISIONS. THE RESPONSIBILITY OF CONTROL, IT IS CERTIFIED THAT DETAILED DESIGN PREPARED IS COMPLIED WITH THE TERM AND CONDITION OF CONTRACT AND DBR
FIRST SUBMISSION GFC (MM) (MM) (MM) (SYS) DESIGN ARCH (ARCH) CHECK AND VERIFICATION OF ACCURACY PROVISIONS. DDC OWN FULL RESPONSIBILITY FOR DESIGN ADEQUACY AND MEETING FUNCTIONAL, PERFORMANCE AND
SLAB 50 35 25 NO OBJECTION CORRECTNESS, COMPLETENESS, OPERATIONAL REQUIREMENT INCLUDING CONSIDERATION FOR INTERFACE REQUIREMENT OF OTHER CONCERNED
A1(594x841mm +2mm)

BEAM/GIRDER 60 50 35 INTEGRATION AND FULL COMPLIANCE DESIGNER/CONTRACTOR AND COMPLIANCE TO STANDARDS, NORMS, SAFETY AND STATUARY RULES & REGULATIONS.
REFERENCE DESIGN DOCUMENT : REVISION AND RESUBMISSION REQUIRED
OF CONTRACT PROVISIONS IN RESPECT
PIER/COLUMN 75 75 50
FOUNDATION (PILE/PILE CAP) 75 75 50 OF DESIGN ANALYSIS AND DRAWING RESTS
REFERENCE DRAWING : CLEAR COVER IS THE LEAST DISTANCE FROM OUTER MOST SURFACE OF STEEL OR BINDING GM(Telecom) GM(Traction) CGM(S&T) CGM(SYM) CGM(P&D) WITH THE DDC
WIRE TO FACE OF THE CONCRETE. MV PB PJ DA SV
Sign : Sign : CHECKED BY INTERFACE ENGG. DESIGNED BY CHECKED BY APPROVED BY ISSUED BY

FILE NAME: L:\SYSTRA_INDIA\CAD_PROJECTS\IN01T19A09 - SURAT DDC PHASE 1\04S\WORKDIR\04S491_X.DWG


by more than 75mm.
· GENERAL e. In case, liner is used and the pile bore is filled with water or drilling mud, bars shall be bent cold.
the bottom part may be concreted using tremie so that the liner is 4. All reinforcement before placement and assembly shall be made · WORKMANSHIP/CONSTRUCTION SPECIFICATION/DETAILING
1. Please do not scale. work to written dimensions only. effectively sealed against ingress of ground water , the upper part may be free from loose mill scales, rust, coats of paints, oil, mud or any
2. All dimensions are in mm and levels in meters unless otherwise specified. connected in dry condition after inspection of top surface of the concrete other substance which may destroy or reduce bond, sand 1. All RCC shall be of controlled grade in accordance with IS:456
3. These notes are to be followed in conjunction with construction drawings and already placed. blasting or other treatment is recommended to clean the unless otherwise specified .
the specification for civil,structural, architectural ,services works and any reinforcement. 2. Nominal maximum size aggregates shall be 20mm unless
instructions issued by the engineer from time to time. · PILES LOAD TEST otherwise specified .
4. Reference made to any drawing shall refer to the latest revision of the said · WATER - 3. If length of the bars shown in the drawings exceeds the maximum
drawing. 1. Pile load test on a concrete pile shall be carried out after 28 days from the 1. Water to be used in concreting, grouting and curing etc shall available bar length, spliced bars may be substituted. splice
5. Reference made to any codes and standards shall refer to the latest revision of time of casting of pile. conform to IS:456-2000. Moreover, for R.C.C structures, the total location shall be at minimum stress location subject to approval of
the same on the date of issue of the tender. 2. Initial load test shall not be less than 2 numbers. chloride content and water soluble sulphate in concrete (from the engineer. Laps shall be staggered in such a way that not more
6. Levels mentioned in structural drawings pertain to top level of structural 3. Routine load test shall not be less than 2% of total number of piles in the various constituent such as water, cement, admixtures and than 50% of bars are lapped at one particular section in any case.
concrete unless otherwise specified. structure nor less than 2 in numbers. aggregates) shall not be more than 0.15 & 4 percent respectively. 4. Bending and fixing of reinforcement shall conform to IS:2502.
7. In case of discrepancy between the specifications and details shown in the 4. The vertical as well as the lateral loads on pile foundation shall be 5. Notation of bar reinforcement shall be as follows:-
drawing, the same shall be brought to the notice of the engineer for confirmed to IS:2911 part IV and the same shall be verified by the engineer · EXPANSION JOINTS- T 8 @ 250
clarification prior to the construction. from time to time prior to the construction . 1. Expansion joint -
Aluminum extrusions, anti-skid serrated top Type of bar as
Bar spacing in mm
· EARTHWORK AND FOUNDATIONS mentioned below
plate(straight/curved) with vapour barrier, sealant for movement Nominal dia of bar in mm
±10 to ±50mm.
1. Not more than 24 hours prior to laying PCC the final T represents grade - Fe : 500D Bar
2. Fabricated steel parts of expansion joints shall be positioned
150mm depth to be excavated and hand ramming to · MATERIAL SPECIFICATION Bar spacing indicated on the drawing shall be perpendicular to the
accurately before the concreting of that portion of the deck slab.
be done unless otherwise specified . bars unless otherwise indicated in the drawing.
3. Presence of manufacturer's representative at the time of
2. All works below ground level shall be executed in · CONCRETE - 6. Fire rating two hours for above ground structures .
positioning of embedded parts and installation of expansion
dry conditions. 1. Grade of concrete for various RCC elements shall be as given
joint is mandatory.
3. 100mm Thick lean concrete (M15) shall be placed below also refer construction drawings . · CONCRETE CASTING -
4. Marginal modifications in the structure details for compatibility
below all foundations and beams/slabs resting on a. Lift walls, retaining walls, basements wall, ancillary building wall : 45Mpa 1. Concrete in the pile shall be cast to full depth in single pour.
with Expansion joint detail shall be permitted subject to approval
ground as per specifications unless otherwise etc. (If required grade can be modified) 2. Concreting shall be carried out up to the pile cap in single pour.
of the Engineer.
specified . b. Pedestal, columns etc : 55Mpa Subsequently kicker of pier shall be made.
4. Excavation in rock, the trenches around the footing (If required grade can be modified) 3. Concrete in the column shaft shall be cast to as per appropriate
· BACKFILL MATERIAL BEHIND RETAINING WALL-
shall be filled up with concrete of M15 grade upto c. Floor slab, covering slabs for underground water tank / : 40/45Mpa method of statement.
1. Backfill Granular soil material behind retaining wall shall have
the top of the rock. basement, chajja slab, staircase slab including steps sill, floor (If required grade can be modified) 4. Concrete in the open foundation slabs shall be cast to full depth in
the properties
FILLED WITH M15 LEAN CONCRETE beams, cantilever beam, inverted beams, gutter beams, coping single pour along with kicker of pier .
as c = 0, Ø = 30°, r = 1800 Kg/M
etc. (If required grade can be modified)
2. 600mm Thick filter material behind RCC retaining wall shall be
d. Pile caps, open foundation : 45Mpa (If required grade can be modified)
laid as per appendix 6 of IRC:78-1983
5. If it is not possible to maintain the founding strata at e. Piles : 40Mpa
3. 100mm dia PVC pipe shall be provided in weep holes.
one level, the founding level shall be stepped as structural element
indicated below provided stepping does not reduce f. Pier Arm at concourse lvl : 55/60Mpa
· REINFORCED EARTH RETAINING WALL-
clearance required for pits, service lines, trenches (Typ. station)
1. Reinforced earth panels, reinforcing strip, back fill material and
etc. below plinth. g. Pier Arm at Platform lvl : 55Mpa
mass concrete strip foundation shall be provided as per
(Typ. station)
technical specification and shall subject to approval of the
h. Pier/Column : 55Mpa
engineer.
FOOTING-1 FOR SOIL a/b > 2
\

a FOR ROCK a/b > 1 2. ordinary Portland cement (43 Grade) conforming to IS:8112 or
\

· BRICK MASONRY
FOOTING-2 high strength ordinary Portland cement (53 Grade) conforming
1. All brick masonry shall be constructed in cement mortar as per
to IS:12269 capable or achieving the required design concrete
b

specifications.
strength shall only be used .
2. External masonry walls shall be provided with adequate lateral
3. To improve workability of concrete and cement grout,
restraint at top by means of shear connectors which should
6. The compacted earth fill and earth work admixtures conforming to IS:6925 and IS:9103 could be
project below the beams at the particular locations.
embankment shall conform to MORTH specification. permitted subject to satisfactory proven use. Admixtures
3. All internal brick partition walls shall be provided with proper
generating hydrogen,nitrogen and chlorides should not be used.
· PILES AND PILE CAPS packing at top between slab/beam and partition walls to ensure
4. Clear cover to any reinforcement shall be as follows unless
lateral restraint at top.
1. Bored cast-in-situ pile casting technique shall be such that there is no otherwise specified :
necking or mixing of the sub soil with the concrete. · DRAINAGE PIPE AS PER PLUMBING & ARCH. DRG.
f. Floor beams : 40 mm
2. Tolerance of piles shall be
g. Column & pedestals : 50 mm · BLOCK WORK
a. Shift not exceeding 75mm at piling platform level.
h. Slabs : 25 mm
3. Reinforcing steel from top of pile after stripping shall project at least
i. Ribs : 35 mm 1. Autoclaved cellular (aerated) concrete blocks shall be used as external/
equal to 45d into pile cap.
j. RCC walls : 40 mm internal non-load bearing walls.
4. Grade of concrete to be used in cast-in-situ pile shall not be less than M40.
k. Retaining walls : 50 mm (soil face) 2. Aerated cellular blocks shall comply with architectural, fire consultant and
5. Cement content in piles shall not be less than 400kg/m3 of concrete.
l. Retaining wall : 30 mm (remote face) the local authorities recommendations.
6. Maximum water cement ratio shall be 0.40 for cast-in-situ piles.
m. Raft slab, beams : 50 mm 3. The maximum density of block work shall not be more than 1000 kg/cum.
7. Rate of placing concrete in the pile shaft shall not be less than 6m (length
n. Base slab : 50mm (soil face) 4. Fire rating of blocks is considered as 2 hours as per architectural details.
of pile) per hour.
o. Base slab : 30mm (remote face)
8. For pile cap leveling course of minimum 100mm thickness of M15 nominal
mix concrete shall be provided . p. Tie beams / Grade beams : 50mm
q. Pile , Pile caps : 75mm
9. Piles subsequently exposed to free water or in case of piles where
concreting is done under water or drilling mud using methods other than m. Open foundation : 50mm
n. Pier : 75mm
the tremie, 10% extra cement over that required for the design grade of
concrete at the specified slump shall be used subjected to a minimum
6. Cement content in concrete shall not be less than 400 kg/cu.m.
quantities.
7. Max. Water cement ratio shall be 0.40 for RCC elements.
10 . Socketed piles : 8. Concrete shall be design mix and have a minimum 28 days
characteristic strength as specified in drawings (Notes).
a. proper cleaning of piles after boring, after lowering the reinforcement and
before concreting shall be done.
REINFORCEMENT -
·
b. On completion of pile bore up to required depth the bottom of pile bore
1.
Thermo-mechanically treated reinforcement bars (Fe 500 D) shall A0 First Issue SM KI SV 16/06/2020
shall be cleaned to remove rock debris, pile bore soil. use of air lift
conform to IS:1786-2008 REV. PARTICULARS DRN. CHD. VER. DATE
technique is also effective in removing the rock debris.
2. Mild steel bars for non structural member (Fe 250) shall conform PROJECT NAME :
c. Chiseling may be resorted in rock strata to penetrate up to required depth .
to IS:432.
d. The size of the cutting tool should not be less than the diameter of the pile END (CH : 21610.) TO KADARSHA NI NAL (CH : 11721.7) ELEVATED VIADUCT & ELEVATED
3. All bars shall be sheared, flame cutting will not be permitted. the
by more than 75mm.
e. In case, liner is used and the pile bore is filled with water or drilling mud,
bars shall be bent cold.
4. All: reinforcement before placement and assembly shall be made
TENDER DRAWING RAIL PROJECT - PH-1.

This Drawings/Design are property of GMRC. The Drawings/Design STATION STRUCTURE DRAWINGS : NOTES EMPLOYER : PROOF CHECK CONSULTANT DETAIL DESIGN CONSULTANT (DDC) CONTRACT ID : GMRC/DDC/ELEV-VDCT-STNS&DEPOT/CORRIDOR-1/PH-1
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE
cannot be issued by any other person, firm, authority or used by SPECIFIED.
GUJARAT METRO RAIL CORPORATION (GMRC) DRAWING NAME/TITLE : SIZE :
consultant for any other purpose/project without prior written 2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED. LIMITED BLOCK-1, FIRST FLOOR, KARMYOGI ALTHAN GAM
3. ANY DISCREPANCIES MUST BE BROUGHT TO THE NOTICE OF THE CONSULTANT BEFORE BHAVAN,BEHIND NIRMAN BHAWAN, SECTOR-10A
permission of GMRC. The consultant shall indemnify GMRC against A1
EXECUTION OF THE WORK AT SITE. GANDHINAGAR - 382010 GENERAL NOTES
all claims arisen due to infringement of any right protected by design, 4. ANY DEVIATION FROM APPROVED LAND PLANS TO BE BROUGHT TO THE NOTICE OF THE
INDIA
CONSULTANT BEFORE EXECUTION. LKT ENGINEERING CONSULTANTS LTD SYSTRA MVA CONSULTING (INDIA) PVT. LTD.
copyright or other intellectual property rights. 5. ANY DEVIATION FROM BOQ DESCRIPTION AND QUANTITY TO BE BROUGHT TO THE NOTICE OF
THE CONSULTANT BEFORE EXECUTION. LOCATION:
6. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURE, THE DESIGN AND DRAWINGS AS CERTIFIED Vatika Mindscapers, Tower-B, 12/3 Floor 9th, 10th
ISSUED FOR AND SUBMITTED BY THE DETAILED DESIGNER & 11th, Mathura Road, NH-2, Sector-27/D, SHEET NO. 1 OF 2
STRUCTURAL, PLUMBING & FIRE FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWING NO : DDCSMP1-TD-TYP-ST-DW-20701
DRAWINGS. CONSULTANT HAVE BEEN PROOF CHECKED Faridabad, Haryana-121013 REV NO. X
CONCEPT DRAWING TENDER DRAWING LEGENDS : ABBREVIATIONS : 7. MINIMUM CLEAR COVER SHALL BE : BY M/S LKT AND RECOMMENDED TO MEGA
SCALE :
TYPE OF STRUCTURE SEVERE ENVIRONMENT
DGM Sr.DGM DGM/ DGM/ FOR APPROVAL. THE DESIGN COMPLIES WITH DATE : 16/06/2020
PRELIMINARY DRAWING FINAL DRAWING(GAD) (Lift & Escalator) (SINGALLING) MANAGER MANAGER MANAGER JGM DBR AND ALL RELEVANT CODAL PROVISIONS. THE RESPONSIBILITY OF CONTROL, IT IS CERTIFIED THAT DETAILED DESIGN PREPARED IS COMPLIED WITH THE TERM AND CONDITION OF CONTRACT AND DBR
SLAB 25MM
FIRST SUBMISSION GFC BEAM/GIRDER 40MM (SYS) DESIGN ARCH (ARCH) CHECK AND VERIFICATION OF ACCURACY PROVISIONS. DDC OWN FULL RESPONSIBILITY FOR DESIGN ADEQUACY AND MEETING FUNCTIONAL, PERFORMANCE AND
NO OBJECTION CORRECTNESS, COMPLETENESS, OPERATIONAL REQUIREMENT INCLUDING CONSIDERATION FOR INTERFACE REQUIREMENT OF OTHER CONCERNED
COLUMN 50MM
A1(594x841mm +2mm)

CENTRAL PIER 75MM INTEGRATION AND FULL COMPLIANCE DESIGNER/CONTRACTOR AND COMPLIANCE TO STANDARDS, NORMS, SAFETY AND STATUARY RULES & REGULATIONS.
REFERENCE DESIGN DOCUMENT : REVISION AND RESUBMISSION REQUIRED
OF CONTRACT PROVISIONS IN RESPECT
FOUNDATION (PILE/PILE CAP) 75MM
OF DESIGN ANALYSIS AND DRAWING RESTS
GM(Telecom) GM(Traction) CGM(S&T) CGM(SYM) CGM(P&D) WITH THE DDC
REFERENCE DRAWING : CLEAR COVER IS THE LEAST DISTANCE FROM OUTER MOST SURFACE OF STEEL OR BINDING
WIRE TO FACE OF THE CONCRETE. MV ST KI SV SV
Sign : Sign : CHECKED BY INTERFACE ENGG. DESIGNED BY CHECKED BY APPROVED BY ISSUED BY

FILE NAME: L:\SYSTRA_INDIA\CAD_PROJECTS\IN01T19A09 - SURAT DDC PHASE 1\20S\LASTREV\20S701_X.DWG