ELEVATOR AIR CONDITIONER

SERVICE MANUAL

Shanghai Sealey Refrigeration Equipment Co., LTD.


http://www.chinasealey.com
Thank you for choosing Sealey elevator air conditioner. For safe and convenient use of this
product, please read the manual carefully and operate it according to the instructions.
Sealey elevator air conditioner adopt Japanese Hitachi compressor, reliable performance, low
noise, no condensed water and high efficiency. It is suitable for all types of vertical elevators.

Catalogue
1 Product Features………………………………………………………………………………………1
2 Electrical Principle Diagram………………………………………………………………………..…1
3 Installation………………………………………………………………………………………………2
3.1 Selection Principle Of Air Inlet And Outlet……………………………………………………..2
3.2 Selection Of Air Conditioner’s Installation Place……………………………………….…..…2
3.3 Installation Drawing………………………………………………………………………………3
4 Unit Control…………………………………………..……………………..……….......……………..4
4.1 Remote Control.....……..……...……………………………….……………………….………..4
4.2 Display Panel Control.....…...………………………………….……………………….………..4
4.3 Running Mode………………………….…………………………………………………………5
5 Maintenance………………………………………………………………..………….……………….5
5.1 Importance Of Maintenance………………...……………………………………………...……5
5.2 Maintenance Items………………………………………………………………………………..6
6 Troubleshooting………………………………………………………………………..………………6
6.1 Common Fault…………………………………………………………………………………….6
6.2 Disposal Of Abnormal Phenomena……………………………………………………………..7
6.3 Non-fault Phenomena…………………………………………………………………………….7

1. Product Features
Small Size
The unit adopt unitary design, use anti-corrosion material, volume is small.
No Condensed Water
Adopt spraying & atomization technology, ensure the effective atomization of condensed water,
don't spill water in high humidity environment.
Low Noise
Adopt famous Hitachi compressor and double silencer design, use damping material to absorb
the vibration.
Environmental Friendly
Adopt high-effective nanometer filter to remove dust, multi-layered defense purification device,
effectively remove turbid air;

2. Electrical Principle Diagram

1
Warning:
(1) Be sure that there is no electricity prior to any electric wiring.
(2) The electric elements to be used shall comply with the national and local standards and keep
each connection secure.
(3) The air conditioner shall be grounded reliably through the allowable ground wire but never
the gas line, water pipe, lightning rod or communication line.
(4) Use 16A socket and TVVBG 8*0.75mm²flat cable.

3. Installation
3.1 Selection Principle Of Air Inlet And Outlet
(1) No block in front of the air inlet and outlet.
(2) Cool supply air will be sent into the car freely, and the loss of cool air should be kept as less
as possible.
(3) Air outlet should be far away from the car wall as far as possible to avoid sweating.
(4) Be sure that the air inside the car can be easily drawn back into the air conditioner.
(5) Air inlet and outlet should be separated to avoid cold air being suctioned directly into air inlet.
3.2 Selection Of Air Conditioner’s Installation Place
(1) Install through beam to lower the noise because of vibration.
(2) Horizontally install to avoid overflow of condensing water.
(3) Adequate space for air suction and air distribution during operation of air conditioner.
2
(4) There is enough space for ventilation
3.3 Installation Drawing

3
4. Unit Control
4.1 Remote Control

(1) “ON/OFF” button: turn on or off the elevator air conditioner.


(2) “MODE” button: shift the operation mode among AUTO, COOL, DRY, HEAT and
VENTILATION, as shown below:

(3) “FAN” button: shift the fan speed among Low, Medium, High speed and Auto.
(4) “▲ / ▼” button: press ▲ or ▼ button, temperature increase or decrease 1℃. The
temperature range is 15℃-30℃. These buttons are noneffective under VENTILATION and DRY
mode.
(5) “TIMER” button: press this button to choose timing ON/OFF function. Press “TIMER” button
at first time, the timing on hour site blinks, press it at second time, the timing on minute site blinks;
Press it at third time, the timing off hour site blinks, press it at fourth time, the timing off minute site
blinks. Press ∧ and ∨ to adjust the setting time.
The time setting range: AM 12:00 ~ 11:59 PM 12:00 ~ 11:59
After finish the time setting, press “SET” button to confirm. If the LCD show “-:--”, means that the
timing ON/OFF function is canceled.
(6) “CLOCK” setting: press ”CLOCK” button to enter into hour setting status, the hour site blinks
in LCD screen, press ∧ or ∨ to adjust hour; press “CLOCK” button again to enter into minute setting
status, the minute site blinks in LCD screen, press ∧ or ∨ to adjust minute;
When the clock setting is ok, press ”SET” button to confirm and press any other button to input
the air conditioner.
(7) “LOCK” button: press this button, the remote control will lock all of the buttons, press again,
relieve the lock.
4.2 Display Panel Control

4
(1) The button name of display panel control:

(2) “ON/OFF” button: turn on or off the elevator air conditioner.


(3) “◀ / ▶” button: press ◀ or ▶ button, temperature increase or decrease 1℃. The temperature
range is 15℃-30℃. These buttons are noneffective under VENTILATION and DRY mode.
(4) “MODE” button: shift the operation mode among AUTO, COOL, DRY, HEAT and
VENTILATION.
(5) “FAN” button: shift the fan speed among Low, Medium, High speed and Auto.
(6) “CLOCK” button:
Press ”CLOCK” button at first time, enter into hour setting status, the hour site blinks in LCD
screen, press ◀ or ▶ to adjust hour; Press ”CLOCK” button at second time, enter into minute setting
status, the minute site blinks in LCD screen, press ◀ or ▶ to adjust minute; After finish the clock
setting, press any other button except ”CLOCK” button to confirm.
Press ”CLOCK” button at third time, set the week, press ◀ or ▶ to adjust week.
Press ”CLOCK” button at fourth time, timing on hour site blinks, press ◀ or ▶ to adjust.
Press ”CLOCK” button at fifth time, timing on minute site blinks, press ◀ or ▶ to adjust.
Press ”CLOCK” button at sixth time, timing off hour site blinks, press ◀ or ▶ to adjust.
Press ”CLOCK” button at seventh time, timing off minute site blinks, press ◀ or ▶ to adjust.
The time setting range: AM 12:00 ~ 11:59 PM 12:00 ~ 11:59
After the setting is ok, press any other button except ”CLOCK” button to confirm. If the LCD
show “-:--”, means that the timing ON/OFF function is canceled.
4.3 Running Mode
Cooling Mode
Press“ON/OFF” button to star air conditioner, air conditioner will run under the recent mode.
Press “MODE” button until the LCD show to enter into cooling mode. Press press ▲ or ▼ button
to adjust temperature. The temperature range is 15℃-30℃. Press “FAN” button to choose the fan
speed.
Heating Mode
The inside fan motor runs at low speed under heating mode. The inside fan motor will shut off 2
minuters later than the unit is turned off.
Ventilation Mode
If the air of lift car is dirty, please choose ventilation mode. Press“ON/OFF” button to star air
conditioner, air conditioner will run under the recent mode. Press “MODE” button until the LCD show
to enter into ventilation mode.
Press “FAN” button to choose the fan speed.
Remark: temperature can’t be adjusted under ventilation mode.

5. Maintenance
Please clean and maintain the air conditioner periodically to keep it run reliably and extend its
service life. Special attention should be drawn to the key components.
5.1 Importance of Maintenance
5
(1) Condenser
As dust accumulated on the fins of the condenser will affect the heat exchange efficiency and
raise the pressure at the high side, it is necessary to check and clean them.
(2) Evaporator
As dust accumulated on the fins of the evaporator will reduce the air flow and lower the cooling
capacity, it is necessary to clean them based on the actual condition.
(3) Filter Screen
As dust accumulated on the filter screen will reduce the air flow and lower the cooling capacity, it
is necessary to clean it frequently.
5.2 Maintenance Items
Maintenance Items
Is the air inlet or outlet clogged?
Are the air supply pipe and the air return pipe tightened
securely?
Is the air duct connected to the car top securely?
Maintenance before Seasonal Operation Is the power cable loosened?
Is the surface of fins accumulated with heavy dust or
stains? If so, the heat exchange efficiency will be
affected. Therefore, it is recommended to clean the fins
by the skilled service person.
Dust from the elevator shaft is likely to attach on the
filter screen, which will reduce the return air flow and
cooling capacity. Therefore, it is suggested to clean the
filter frequently. Once every week is preferred.
Maintenance in Seasonal Operation The filter screen is allowed to be cleaned by the
vacuum cleaner or by rinsing. If the filter screen is quite
dirty, use the lukewarm (lower than 30℃ ) neutral
detergent and dry it in shade.

6. Troubleshooting
6.1 Common Fault
Fault Phenomenon Possible Causes Solutions
The power switch is not connected Connect power switch
The power switch fuse is burnt Change the fuse
The battery inside the remote
Change battery
control has run out
Don’t reach the time of timing on Wait or cancel the original time setting
Temperature setting is improper Set the proper temperature
Blow air, but the
Air filter is blocked by dust or filth Clean air filter
cooling is bad
Air inlet or outlet mouth is blocked Clean the blockage
Clean the blockage, restart the air
Air inlet or outlet mouth is blocked
Blow air, but can’t conditioner
cool Compressor 3 minutes protection Wait
Temperature setting is improper Set the proper temperature

6
Remark:
Mobile phone can cause air conditioner misoperation. In the event of this kind of phenomenon,
please unplug the power plug in a few seconds and then plug in, then restart the air conditioner.
When encounter thunderstorm weather, please disconnect the power switch, or lightning can
damage the unit.
6.2 Disposal Of Abnormal Phenomena
If above problems can’t be solved, or some following phenomenons occur, please turn off the
elevator air conditioner and cut off the power supply, then contact supplier.
(1) Running indicator light t blinks quickly, remote control show “E”. The light still blinks after shut
off power supply and restart.
(2) Fuse is burnt frequently or circuit breaks frequently.
(3) Other abnormal phenomenons.
6.3 Non-fault Phenomena
(1) Don't run immediately: the system doesn’t start running after turn on the unit, but if the
indicator light is on, it means air conditioner is normal. In case of overload, the controller has 3
minutes start-up delay protection function, the unit will run after 3 minutes.
(2) The system sound is conspicuous when the air conditioner start running, then it tends to be
normal gradually. This is the sound from plastic parts heat-expansion and cold-contraction; There is
transitory sound after turn off the unit, this is the sound from refrigerant stop flowing or change the
rate of flow. All of these sounds are normal phenomenon.
(3) Blow out dust: if the air conditioner is not be used in long time, the dust in air conditioner will
be blown out when the unit is used at the first time.