A1 Key To Component: Diagram, Piping & Instrumentation Ac Nirvana of Hot Discharge-Hoc

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

81811.10.

10

18,579
8 7 6 5 4 3 2 1 825,579

REVISIONS
ZONE REV ECN DESCRIPTION DATE DRAWN APP'D

A 79937 ORIGINAL RELEASE 2011JUL18 B.BASAVA T.VINCENT

D 68 ISOLATION VALVE (CUSTOMER SUPPLIED) D


67 TYPICAL CUSTOMER DOWNSTREAM AIR TREATMENT
66 RECEIVER TRAP AUX WARNING
64 DRYER AUX WARNING
63 DRYER CONDENSATE DISCHARGE (CUSTOMER EQUIPMENT)
62 RECEIVERS (CUSTOMER EQUIPMENT)
61 LINE FILTERS (CUSTOMER EQUIPMENT)
60 HOC DRYER (CUSTOMER EQUIPMENT)
50 DRIVE MOTOR - VARIABLE SPEED
49 9APT-REMOTE AIR PRESSURE TRANSDUCER
48 6OPT-OIL FILTER OUT PRESSURE TRANSDUCER
47 5OPT-OIL FILTER INLET PRESSURE TRANSDUCER
46 5OTT-OIL MANIFOLD TEMPERATURE THERMISTOR
44 4APT-COMPRESSOR DISCHARGE PRESSURE TRANSDUCER
43 4ATT-HP DISCHARGE TEMPERATURE RTD
42 3APT-HP DISCHARGE PRESSURE TRANSDUCER
41 3ATT-HP INLET TEMPERATURE THERMISTOR
40 2APT-HP INLET PRESSURE TRANSDUCER
C C
39 2ATT-LP DISCHARGE TEMPERATURE RTD
38 1AVPT-LP INLET VACUUM TRANSDUCER
37 1ATT-LP INLET TEMPERATURE THERMISTOR
36 GEAR CASE BREATHER
35 OIL BYPASS CHECK VALVE
34 OIL FILTER
33 OIL TEMPERATURE CONTROL VALVE
32 OIL COOLER
31 OIL BYPASS VALVE
30 OIL PUMP
29 OIL SUMP
28 BLOWDOWN CONDENSATE BALL VALVE(SHIPPED LOOSE)
27 BLOWDOWN CONDENSATE DISCHARGE CUSTOMER CONNECTION)
26 BLOWDOWN TIMED CONDENSATE SOLENOID 9SV
25 BLOWDOWN CONDENSATE STRAINER
24 BLOWDOWN BALL VALVE (BYPASS CONDENSATE SOLENOID)
23 INTERSTAGE CONDENSATE BALL VALVE (SHIPPED LOOSE)
22 INTERSTAGE CONDENSATE DISCHARGE(CUSTOMER CONNECTION) B
B
21 INTERSTAGE TIMED CONDENSATE SOLENOID 6SV
20 INTERSTAGE CONDENSATE STRAINER
19 INTERSTAGE CONDENSATE CHECK VALVE
18 INTERSTAGE BALL VALVE(BYPASS CONDENSATE SOLENOID)
17 PRESSURE RELIEF VALVE
16 INTERSTAGE PRESSURE RELIEF VALVE
15 BLOWDOWN SILENCER
14 BLOWDOWN SOLENOID VALVE 3SV
13 BLOWDOWN SILENCER
12 INTERSTAGE BLOWDOWN SOLENOID VALVE 5SV
11 AIR DISCHARGE (CUSTOMER CONNECTION)
10 CHECK VALVE
9 MOISTURE SEPARATOR
8 BLOWDOWN COOLER
7 HP DISCHARGE SILENCER
6 HP AIREND
5 INTERSTAGE MOISTURE SEPARATOR
A 4 INTERCOOLER A
DO NOT SCALE DRAWING
402,81 615,81 825,81

STANDARD TOLERANCES WARNING: THE EXPORT OR REEXPORT OF THIS DRAWING OR A PRODUCT PRODUCED
3 LP DISCHARGE SILENCER BY THIS DRAWING IS SUBJECT TO U.S. EXPORT ADMINISTRATION REGULATIONS
DRAWING CONFORMS TO
AND OTHER APPLICABLE GOVERNMENT RESTRICTIONS OR REGULATIONS.
ALL DIMENSIONS ARE IN THIRD ANGLE PROJECTION
2 LP AIREND MILLIMETERS PROPRIETARY NOTICE ASME Y14.5M - 1994 DRAWN DATE
[INCHES (IF SHOWN)] CAD GENERATED DRAWING, B.BASAVA 2011JUL18
1 AIR FILTER THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND IS NO MANUAL REVISIONS ALLOWED CHECKED DATE TITLE

ITEM NO. DESCRIPTION UNSPECIFIED TOLERANCES: GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY RECEPTION
AND RETENTION OF THE DRAWING ACCEPTS THE DRAWING IN CONFIDENCE UNLESS OTHERWISE SPECIFIED:
H.XIANG
APPROVED
2011JUL18
DATE
DIAGRAM, PIPING & INSTRUMENTATION
AND AGREES THAT, EXCEPT AS AUTHORIZED IN WRITING BY

KEY TO COMPONENT WHOLE : 1


INGERSOLL-RAND CO. IT WILL (1) NOT USE THE DRAWING OR ANY COPY
THEREOF OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION
- REMOVE ALL BURRS AND SHARP CORNERS
- WELD SYMBOLS TO BE IN ACCORDANCE T.VINCENT 2011JUL18 AC NIRVANA OF HOT DISCHARGE-HOC
ONE PLACE (.X) : 0.5 WITH ANSI/AWS A2.4 DIAGRAM, PIPING & INSTRUMENTATION AC NIRVANA OF HOT DISCHARGE-HOC

THEREIN; (2) NOT COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS SIZE ESTIMATED WEIGHT DWG NO. REV
TWO PLACE (.XX) : 0.25
A1 23920507 A
EITHER THE DRAWING OR THE CONFIDENTIAL OR TRADE SECRET (KG UNLESS OTHERWISE SPECIFIED)
ANGLES (.X) : 1 INFORMATION THEREIN; AND (4) UPON COMPLETION OF THE NEED TO COPYRIGHT @ 2011 NOMENCLATURE
-
RETAIN THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL Ingersoll Rand
18,18
Ingersoll-Rand Industrial Technologies 402,18
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. ALL RIGHTS RESERVED
SCALE:
0.25 UNIT:
NL37-160KW-OF SHEET
1 OF 2 For Internal Use:23920507|ASSEM|A.2|Pujeri, C-Sadashiv|20-Jul-11 02:58:42 PM|In Work

8 7 6 5 4 3 2 1
21-Jul-2011 08:11:16 (model A.2/A.2)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED
81811.10.10

18,579
18,579
8 7 6 5 4 3 2 1 826,579

67

44 64
62 49
P
D D
68
R P
11 D F
10
60
14
61
17
63 66
15
8 9

37 24 25 26 27
T 39

C 46 T 28 C
1 38 50 M
T V
2 3 4 16 41 40

T P

7 6 5
12
T P
13
B 18 19 20 21 22 B
PIPING LEGEND

43 42 COMPRESSED AIR
33 MODULE
23
48 47 32 30
COOLANT

P P 31 CONDENSATE

34 COMPRESSOR
ENCLOSURE

T SENSOR
CONNECTION
EQUIPMENT
DOWNSTREAM
35 36 OF COMPRESSOR
COOLING
29 WATER

A A

636,54 825,54

PROPRIETARY NOTICE TITLE

THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET


INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND DIAGRAM, PIPING & INSTRUMENTATION
IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY
AC NIRVANA OF HOT DISCHARGE-HOC
DIAGRAM, PIPING & INSTRUMENTATION AC NIRVANA OF HOT DISCHARGE-HOC

RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE


DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE

23920507
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT SIZE DWG NO. REV
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN A1 A
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE: SHEET
18,18
18,18 636,18
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 0.25 2 OF 2

8 7 6 5 4 3 2 1
21-Jul-2011 08:11:16 (model A.2/A.2)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED

You might also like