MQB100F 7,5/4AW 240 Technical Specification: Data Sheet
MQB100F 7,5/4AW 240 Technical Specification: Data Sheet
MQB100F 7,5/4AW 240 Technical Specification: Data Sheet
Technical specification 3~ 50 Hz
30 %%
H/ m Head4050 %
60 % — 240 ∆p / kPa
70 %
10kW<P2<100kW: Grade 3B
0 0
P2>100kW: Grade 2B
79.72
η/% Hydraulic efficiency
40
0
NPSH / m NPSH-values
2.219
2
0 40 80 110.2
120 160 200 240 Q / m³/h
Construction materials
Case Cast iron EN-GJL 250
Motor data Shaft AISI 431
Rated voltage 400 V Hydraulic Cast iron EN-GJL 250
Frequency 50 Hz Impeller Cast iron EN-GJL 250
Motor phases 3~ Painting Bi-epoxy 200 µm (7,9 thou) sea
Number of poles 4 water resistant
Rated power P2 7.50 kW Screws Stainless steel A2-70
Incoming power P1 8.30 kW Gaskets NBR
Rated current 14.5 A
rpm 1460 1/min
Efficiency 90.4 % Construction features
cos φ 0.830 Cooling jacket -
Rated torque 49.1 Nm Main cable 7G1,5 + 3x1
Start* Star-delta Cable length 10 m (32,8 ft)
Starting current 32.2 A Mechanical seals 2 in sil.carbide (SiC) in oil chamber
Starting torque 39.7 Nm Flushing valve - drilling -
Degree of protection IP 68 Drilling variant PA
Insulation class H Weight* 261.3 kg
Motor efficiency class ref IE3 * cable and fixing system excluded
Motor size M10S Monitoring features
*use soft start, inverter or star/delta method to start and stop the pump Monitoring option BB
if the power is greater than or equal to 30 kW.
- n.3 bimetal thermal protectors (Klixon) in series
Hydraulic
Free passage 45 mm - n.1 double leakage sensor , mechanical seals chamber
Impeller type Open channel impeller and stator housing (1 signal)
- No bearing thermistors
No. of vanes 3
Nominal impeller size 240.0 mm - No vibration sensor
Max. hydraulic efficiency 81.3 %
Suction DN 150 UNDRILLED
Discharge DN 100 EN 1092-2
Curve tolerance UNI EN ISO 9906:2012
Rev. 3 - 06-07-2018 Created on: 2021-06-15
All data shown are not binding. Tsurumi reserves the right to change data and dimensions without notice.
tsurumi-global.com Page 1 / 4
Data sheet
MQB100F 7,5/4AW 240
Characteristic curves according to UNI EN ISO 9906:2012 for pumps with standard material combination
13 130
78 % 120
12
11 75 % 110
10 100
70 % 90
9
8 80
60 % 70
7
6 50 % 60
5 50
4 40
3 30
2 20
1 10
▕◄ Application range ►▏
10kW<P2<100kW: Grade 3B
P2<10kW: paragraph 4.4.2
P2>100kW: Grade 2B
0 0
P₂ / kW Shaft power P2
6.041
6
5
4
3
2
1
η/% Hydraulic efficiency
79.72
60
40
20
0
NPSH / m NPSH-values
3.5
2.5
2.219
2
1.5
0 20 40 60 80 100 110.2120 140 160 180 200 220 240 260 Q / m³/h
1500 1 1 1
1470 0% 25% 50%
0.95 75% 100% 0.95 0.95
1400 A1 125%
0.9 0.9 0.91
0.9
1300
0.85 0.85
0.838 0.85
1200 0.8
0.788 0.8 0.8
0 0 0 0
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6.041
6 6.5 7 7.5 8 8.5 9 9.5 P₂ / kW
Dimensional drawing 3 ~ 50 Hz
Installation type
P: bottom coupling device - vertical discharge DN100 - guide pipes 2"
Wet/dry use Drilling variant Flushing valve - drilling
WET PA -
Discharge Suction Pressure rating (suction/discharge):
DN 100 EN 1092-2 DN 150 UNDRILLED -/PN 10
Accessory Accessory code Accessory variant
DAC 100/100V+KAF 116-2" EN (P) 9001.033 -
The minimum indicated levels do not prevent the formation of vortexes and/or cavitation