MQB100F 7,5/4AW 240 Technical Specification: Data Sheet

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Data sheet

MQB100F 7,5/4AW 240

Technical specification 3~ 50 Hz
30 %%
H/ m Head4050 %
60 % — 240 ∆p / kPa
70 %

Characteristic curves according to UNI EN ISO 9906:2012


75 78
% %
80 %
16
15.92 81.3% 80 % 160
155.9
78 %
12 75 % 120
A1

for pumps with standard material combination


70 %
60 % 80
8 50 %
4 40
▕◄ Application range ► ▏

10kW<P2<100kW: Grade 3B
0 0

P2<10kW: paragraph 4.4.2


P₂ /6.041
kW Shaft power P2
4

P2>100kW: Grade 2B
79.72
η/% Hydraulic efficiency
40
0
NPSH / m NPSH-values

2.219
2

0 40 80 110.2
120 160 200 240 Q / m³/h

Pump Operating limits (standard pumps)


Series AVANT MQ Max. ambient temperature 40 °C
Pump name MQB100F 7,5/4AW 240 Max. density treated liquid 1100 kg/m³
Configuration PAAABB104Y5T0NNNN pH treated liquid 6 ÷ 14
Standard CE Max. start per hour (equally distributed) 20
Wet/dry use WET
Max. acoustic pressure level 70 dB
Operating mode S1 - Continuous use

Construction materials
Case Cast iron EN-GJL 250
Motor data Shaft AISI 431
Rated voltage 400 V Hydraulic Cast iron EN-GJL 250
Frequency 50 Hz Impeller Cast iron EN-GJL 250
Motor phases 3~ Painting Bi-epoxy 200 µm (7,9 thou) sea
Number of poles 4 water resistant
Rated power P2 7.50 kW Screws Stainless steel A2-70
Incoming power P1 8.30 kW Gaskets NBR
Rated current 14.5 A
rpm 1460 1/min
Efficiency 90.4 % Construction features
cos φ 0.830 Cooling jacket -
Rated torque 49.1 Nm Main cable 7G1,5 + 3x1
Start* Star-delta Cable length 10 m (32,8 ft)
Starting current 32.2 A Mechanical seals 2 in sil.carbide (SiC) in oil chamber
Starting torque 39.7 Nm Flushing valve - drilling -
Degree of protection IP 68 Drilling variant PA
Insulation class H Weight* 261.3 kg
Motor efficiency class ref IE3 * cable and fixing system excluded
Motor size M10S Monitoring features
*use soft start, inverter or star/delta method to start and stop the pump Monitoring option BB
if the power is greater than or equal to 30 kW.
- n.3 bimetal thermal protectors (Klixon) in series
Hydraulic
Free passage 45 mm - n.1 double leakage sensor , mechanical seals chamber
Impeller type Open channel impeller and stator housing (1 signal)
- No bearing thermistors
No. of vanes 3
Nominal impeller size 240.0 mm - No vibration sensor
Max. hydraulic efficiency 81.3 %
Suction DN 150 UNDRILLED
Discharge DN 100 EN 1092-2
Curve tolerance UNI EN ISO 9906:2012
Rev. 3 - 06-07-2018 Created on: 2021-06-15
All data shown are not binding. Tsurumi reserves the right to change data and dimensions without notice.
tsurumi-global.com Page 1 / 4
Data sheet
MQB100F 7,5/4AW 240

Pump performance curves 3 ~ 50 Hz


Impeller type Nominal impeller size Free passage Created by
Open channel impeller 240.0 mm 45 mm

Density Viscosity No. of vanes Discharge Suction Data version


998.3 kg/m³ 1.005 mm²/s 3 DN 100 DN 150
DUTY POINT
Flow Head Shaft power P2 Power input P1 Hydraulic efficiency Total efficiency NPSH
110.2 m³/h 15.9 m 6.0 kW 6.6 kW 79.7 % 72.5 % 2.2 m

H/ m Head — 240 ∆p / kPa


30 % 220
22 40 %
50 % 210
21
60 % 200
20
70 % 190
19
75 % 180
18
78 % 170
17
80 % 160
16
15.92 155.9
150
15 81.3%
14 140
A1
80 %

Characteristic curves according to UNI EN ISO 9906:2012 for pumps with standard material combination
13 130
78 % 120
12
11 75 % 110
10 100
70 % 90
9
8 80
60 % 70
7
6 50 % 60
5 50
4 40
3 30
2 20
1 10
▕◄ Application range ►▏

10kW<P2<100kW: Grade 3B
P2<10kW: paragraph 4.4.2

P2>100kW: Grade 2B
0 0
P₂ / kW Shaft power P2

6.041
6
5
4
3
2
1
η/% Hydraulic efficiency
79.72

60

40

20

0
NPSH / m NPSH-values

3.5

2.5
2.219
2

1.5

0 20 40 60 80 100 110.2120 140 160 180 200 220 240 260 Q / m³/h

Rev. 3 - 06-07-2018 Created on: 2021-06-15


All data shown are not binding. Tsurumi reserves the right to change data and dimensions without notice.
tsurumi-global.com Page 2 / 4
Data sheet
MQB100F 7,5/4AW 240

Motor performance curves 3 ~ 50 Hz


Motor Rated power Rated voltage Motor efficiency Created by
7,5/4 AW 7.5 kW 400 V 90.4 % LB
Number of poles Nominal Speed Rated current cos φ Data version
4 1460 1/min 14.5 A 0.83 01-06-2014
Starting current Start Rated torque
32.2 A Star-delta 49.1 Nm

0 10 20 30 40 50 60 70 80 90 100 110 120 P2/P2n / %

n / 1/min cos φ 80.54 % — cos φ I/In η


2000 —n
1.3 — I/In 1.3 1.3
1900 —η
1.25 1.25 1.25

1800 1.2 1.2 1.2

1.15 1.15 1.15


1700
1.1 1.1 1.1
1600
1.05 1.05 1.05

1500 1 1 1
1470 0% 25% 50%
0.95 75% 100% 0.95 0.95
1400 A1 125%
0.9 0.9 0.91
0.9
1300
0.85 0.85
0.838 0.85

1200 0.8
0.788 0.8 0.8

0.75 0.75 0.75


1100
0.7 0.7 0.7
1000
0.65 0.65 0.65

900 0.6 0.6 0.6

0.55 0.55 0.55


800
0.5 0.5 0.5
700
0.45 0.45 0.45

600 0.4 0.4 0.4

0.35 0.35 0.35


500
0.3 0.3 0.3
400
0.25 0.25 0.25

300 0.2 0.2 0.2

0.15 0.15 0.15


200
0.1 0.1 0.1
100
0.05 0.05 0.05

0 0 0 0
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6.041
6 6.5 7 7.5 8 8.5 9 9.5 P₂ / kW

Symbol No load 25 % 50 % 75 % 100 % 125 %


P₂ / kW 0 1.875 3.75 5.625 7.5 9.375
P₁ / kW 0.4047 2.187 4.103 6.172 8.288 10.55
n / 1/min 1500 1491 1482 1472 1461 1448
cos φ 0.09011 0.4275 0.6492 0.7717 0.8257 0.8565
I/ A 6.482 7.385 9.123 11.54 14.49 17.78
s/% 0 0.5732 1.18 1.846 2.593 3.44
M / Nm 0 12.01 24.16 36.48 49.02 61.81
η/ % 0 85.73 91.39 91.14 90.5 88.88
Tolerances according to EN 60034-1
Rev. 3 - 06-07-2018 Created on: 2021-06-15
All data shown are not binding. Tsurumi reserves the right to change data and dimensions without notice.
tsurumi-global.com Page 3 / 4
Data sheet
MQB100F 7,5/4AW 240

Dimensional drawing 3 ~ 50 Hz
Installation type
P: bottom coupling device - vertical discharge DN100 - guide pipes 2"
Wet/dry use Drilling variant Flushing valve - drilling
WET PA -
Discharge Suction Pressure rating (suction/discharge):
DN 100 EN 1092-2 DN 150 UNDRILLED -/PN 10
Accessory Accessory code Accessory variant
DAC 100/100V+KAF 116-2" EN (P) 9001.033 -

Note: Accessory must be ordered separately

The minimum indicated levels do not prevent the formation of vortexes and/or cavitation

L1: Minimum operating level for continuous use


L2: Minimum operating level for discontinuous use (excluding -EX/FM models) * clearance from bottom suggested
Rev. 3 - 06-07-2018 Created on: 2021-06-15
All data shown are not binding. Tsurumi reserves the right to change data and dimensions without notice.
tsurumi-global.com Page 4 / 4

You might also like