JORDAHL® EXPERT Punching Shear - Design 1. Input Information

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Responsible: Construction project:

Construction member:
Position:
Date: August 13, 2021

JORDAHL® EXPERT Punching shear - Design


1. Input information
Column type Rectangular edge column
Column dimension cx / cy = 36 in / 36 in
Edge rb = 0 in

Slab type In-situ concrete slab


Slab thickness h = 9 in
Concrete cover top/bottom co / cu = 1.1 in / 0.75 in
Effective depth dx / dy = 7 in / 7 in
Concrete strength 6000 psi
Density Normal concrete
Prestress fpc = 125 psi

Punching shear load Vu = 134 kip


Unbalanced moment Mux / Muy = 215 kip-ft / 26.5 kip-ft

Reinforcement diameter ϕx / ϕy = #5 / #4
Distances sx / sy = 12 in / 12 in

2. Output information (ACI 318-14)


2.1 Inner Critical Section (d/2 outside of column face)
2.1.1 Common Properties
Area Ac = 854 in²
Critical section perimeter b0 = 122 in
2.1.2 Natural Axis Properties
Centroid coordinate ex / ey = 0 in / 8.711 in
Section moment of inertia Ix / Iy = 1.479·105 in⁴ / 3.020·105 in⁴
Section product of inertia Ixy = 0 in⁴
2.1.3 Principal Axis Properties
Centroid coordinate e1 / e2 = -8.711 in / 0 in
5 5
Section moment of inertia I1 / I2 = 3.020·10 in⁴ / 1.479·10 in⁴
Principal axis rotation θ = 90.0 °
Moment fraction γ1 / γ2 = 0.4102 / 0.3611
Unbalanced moment Mu1 / Mu2 = 26.5 kip-ft / -215 kip-ft

JORDAHL H-BAU AG Wasterkingerweg 2, CH-8193 Eglisau JORDAHL® EXPERT Punching shear Page 1 from 4
www.jordahl-hbau.ch Version: 4.2.2.39
Responsible: Construction project:
Construction member:
Position:
Date: August 13, 2021

2.1.4 Stresses
Maximum shear stresss vu = 410.5 psi
x/y = 21.5 in / -18 in
Shear resistance (concrete only) ϕvc = 216.2 psi
Shear resistance (with studrails) ϕvn = 649.2 psi
Shear resistance (upper limit) ϕvn,max = 464.8 psi

2.2 Outer Critical Section (d/2 outside of reinforced zone)


2.2.1 Common Properties
Area Ac = 2492.1 in²
Critical section perimeter b0 = 356 in
2.2.2 Natural Axis Properties
Centroid coordinate ex / ey = 0 in / 53.842 in
6 7
Section moment of inertia Ix / Iy = 3.415·10 in⁴ / 1.342·10 in⁴
Section product of inertia Ixy = 0 in⁴
2.2.3 Principal Axis Properties
Centroid coordinate e1 / e2 = -53.842 in / 0 in
7 6
Section moment of inertia I1 / I2 = 1.342·10 in⁴ / 3.415·10 in⁴
Principal axis rotation θ = 90.0 °
Moment fraction γ1 / γ2 = 0.4656 / 0.2927
Unbalanced moment Mu1 / Mu2 = 26.5 kip-ft / -215 kip-ft
2.2.4 Stresses
Maximum shear stresss vu = 115.2 psi
x/y = 105.5 in / -18 in
Shear resistance ϕvc = 116.2 psi

3. Elements
Number of studrails per column = 12
Number of studs per studrail = 24
Stud diameter D = 0.75 in
Stud spacing S / S0 = 3.5 in / 3.5 in
Overall height of studrail OAH = 7.15 in
Overall length of studrail OAL = 87.5 in

JORDAHL H-BAU AG Wasterkingerweg 2, CH-8193 Eglisau JORDAHL® EXPERT Punching shear Page 2 from 4
www.jordahl-hbau.ch Version: 4.2.2.39
Responsible: Construction project:
Construction member:
Position:
Date: August 13, 2021

4. Note
• The design against punching shear failure is based on the rules of ACI 318-14.
• This calculation is bases on product specific properties of DECON® Studrails®. Changes, even to similar
products, are only possible with new calculations.
• All data have to be checked with the given edge boundaries and the feasibility. DECON assumes no
liability for the input data of the user.

JORDAHL H-BAU AG Wasterkingerweg 2, CH-8193 Eglisau JORDAHL® EXPERT Punching shear Page 3 from 4
www.jordahl-hbau.ch Version: 4.2.2.39
Responsible: Construction project:
Construction member:
Position:
Date: August 13, 2021

JORDAHL H-BAU AG Wasterkingerweg 2, CH-8193 Eglisau JORDAHL® EXPERT Punching shear Page 4 from 4
www.jordahl-hbau.ch Version: 4.2.2.39

You might also like