E Docs Purchase Section Schedule of Rates Common-Sr-2016-17

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 181

Rates of various Line materials and Labour charges used in cost sheets for general

works

Labour
Materials
SL.NO Particulars Unit
rate in Rs.
charges
(Casual) in Rs
1 2 3 4 5
RCC Poles
a) 9.5 M 350kg WL Nos. 7675 1373
I b) 9M 145kg WL Nos. 5941 1060
c) 9M 150kg WL Square section Nos. 7210 1060
d) 8M 115kg WL Nos. 4351 848
II
PCC Poles
8M PCC Poles 140kg WL Nos. 2495 848
PSC Poles
a) 11M 365kg WL Nos. 7924 1552
III
b) 9M 200kg WL Nos. 3401 1060
d) 8M 200kg WL Nos. 2942 848

IV
Pre-Stressed Tubular Spun Pole
11M Long Nos. 15800 2353
PSCC Poles
9M PSCC pole WL 300Kg Nos. 4578 1060
9M PSCC pole 160Kg WL in Transverse
direction and 136Kg WL in Longitudinal Nos. 3558 1060
directional
Guy Less Pole Nos. New Item
Double Pole Structure complete
including 5 KG , 8SWG G.I. Wire for
V Structure Grounding
a) 9M RCC Poles Set 15910 3252
b) 8M RCC Poles Set 12730 3104
c) 9M PSCC Poles with 300Kg WL Set 13184 3252
Three Pole structure complete
including 5 KG , 8SWG G.I. Wire for
VII Structure Grounding
a) 9M RCC Poles Set 27446 6271
b) 8M RCC Poles Set 22676 6049
c) 9M PSCC Poles with 300Kg WL Set 23357 6271
Transformer Structure complete
VII with cross arms braces, clamps,
bolt&nuts and washers,
For 25/63 kVA
1) a) Using 2nos 9M RCC Poles Set 19271 4115
b) Using 2 nos 8M RCC Poles Set 16091 3560
c) 9M PSCC Poles with 300Kg WL Set 16545 4115
For 25/63 kVA- Star Rated Transformers
1) a) Using 2nos 9M RCC Poles Set 22532 4115
b) Using 2 nos 8M RCC Poles Set 19352 3560
c) 9M PSCC Poles with 300Kg WL Set 19806 4115
For 100 / 250 kVA
a) Using 2nos 9M RCC Poles Set 24575 4238
b) Using 2 nos 8M RCC Poles Set 21395 3816
2)
c) 9M PSCC Poles with 300Kg WL Set 21849 4238
Note: The items V, VI, includes the cost of poles, structure materials & 5 kgs of G.I wire required
for earthing of structure materials.
Fixing Single pole mounted
transformer kit on 9 mtr RCC pole
(square sec) / 9 Mtr PSCC pole
3) 300KG WL (Excluding Errection of
pole)
for 25/63kVA Transformer Set 4088 1016
for 100kVA Transformer Set 6129 1016
For Single pole mounted
transformer kit for 100/250kVA on
4) Set 23035 2033
11 mtr spun pole (Excluding
Errection of pole)
11 kV Horizontal cross arm with
H.T.Single top support,
VIII clamp,bolts, nuts and washers MS
a) For RCC Poles Set 382 99
b) For PSC Poles Set 377 99
b) For PCC Poles Set 374 99

11 kV Horizontal cross arm with


H.T.Single top support,
clamp,bolts, nuts and washers GI
a) For RCC Poles Set 505 99
b) For PSC Poles Set 498 99
b) For PCC Poles Set 493 99
11 kV Horizontal cross arm,
clamp,bolts, nuts and washers for
IX DC Lines MS
a) For RCC Poles each 316 81
b) For PSC Poles each 311 81
b) For PCC Poles each 308 81
11 kV Horizontal cross arm,
clamp,bolts, nuts and washers for
DC Lines GI
a) For RCC Poles each 422 81
b) For PSC Poles each 415 81
b) For PCC Poles each 411 81
4-Pin cross arm with pole clamp ,
bolts, nuts and washers with
X braces MS
a) RCC Poles Set 263 96
b) For PSC Poles Set 258 96
b) PCC Poles Set 255 96
4-Pin cross arm with pole clamp ,
bolts, nuts and washers with
braces GI
a) RCC Poles Set 352 96
b) For PSC Poles Set 345 96
b) PCC Poles Set 340 96
2-Pin cross arm with pole clamp ,
bolts, nuts and washers with
XI braces MS
a) RCC Poles Set 162 96
b) For PSC Poles Set 157 96
b) PCC Poles Set 154 96
2-Pin cross arm with pole clamp ,
bolts, nuts and washers with
braces GI
a) RCC Poles Set 219 96
b) For PSC Poles Set 212 96
b) PCC Poles Set 207 96
LT Cross arm for vertical
XII configuration with Set 626 287
clamps,bolts,nuts and washers
HT Single Top support with
XIII Set 89 64
bolt,nuts and washers
LT Single Top support with
XIV Set 69 64
bolt,nuts and washers
Insulators
a) 11kV Ceramic Pin insulator with GI pin No 94
b) No.15 Strain Insulator No 33
c) No.8 Strain Insulator No 14
d) 1.1 KV Ceramic Pin Insulator With GI pin No 38
11 KV, 5KN composite / polymeric Pin
No 165
Insulator (20mm dia FP rod)
11 KV, 5KN composite / polymeric Pin
No 195
Insulator (24mm dia FP rod)
e) 45 kN Disc Insulator No 290
Included in
f) 70 kN Disc Insulator(Ball&Socket type) No 490
stringing
g) 90 kN Disc Insulator(Ball&Socket type) No 490
h) 11 kV Solid core Insulator No 152
i) Silcon rubber composite insulator / 11KV 45
No 170
KN Polymeric Insulator.
j)11KV 70 KN Polymeric insulator. No 287
G I Wires & Guy Wires
7/10 SWG Guy Wire MT 56267
8 SWG GI Wire MT 54674
10 SWG GI Wire MT 57683
GI Barbed Wire 12 SWG MT 67882
Conductor
a) Weasel ACSR km 20100 1913
XVI
b) Rabbit ACSR km 33676 2608
c) Coyote ACSR km 92708 4555
Providing guarding at Road Crossings, 603
Telephone Line Crossings . (Including labour mtr 68 (each upto a
for fixing of necessary cross arms) span of 60 mtrs)
603
Providing guarding between HT & LT line.
(each upto a
XVII (Including labour fixing of necessary cross mtr 68
span of 40
arms)
mtrs)
Providing guarding between HT & LT line. 1059
(Including labour fixing of necessary cross mtr 68 ( span of
arms) above 40 mtrs)
a) Guy set with No.15 strain insulator &
Concreting materials as per Drwg No. Set 742 354
BESCOM/GM/CP/7/Dt; 24.10.07
b) Guy set with 2Nos. 15 strain insulator &
XVIII Concreting materials as per Drwg No. Set 775 374
BESCOM/GM/CP/7/Dt; 24.10.07
b) Guy set with No. 8 strain insulator &
Concreting materials as per Drwg No. Set 723 354
BESCOM/GM/CP/7/Dt; 24.10.07
XX EG Stirrup With GI Lacing Set/2Nos. 370 99
XXI Spiral Earth Electrode Set 207 55
Anti climbing device (12 Mtrs GI Barbed wire) Nos. 64 25
XXII Caution / Danger Board Nos. 120 49
Distribution Transformer,
3-Phase, 11kV/433 V with oil
a) 15 kVA (Copper wound) Nos. 49980 682
b) 25 kVA (Aluminium wound) Nos. 56480 682
c) 25kVA BEE - 3 Star rated (Aluminium wound) Nos. 51560 682
c) 25kVA BEE - 4 Star rated (Aluminium
Nos. 54969 682
wound)
d) 63 kVA (Aluminium wound) Nos. 81440 682
e) 63kVA BEE - 3 Star rated (Aluminium wound) Nos. 93726 682
XXII e) 63kVA BEE - 4 Star rated (Aluminium
Nos. 94757 682
wound)
f) 100 kVA (Aluminium wound) Nos. 101570 910
f) 100 kVA (Aluminium wound) BEE 3-Star rated Nos. 121422 910
f) 100 kVA (Aluminium wound) BEE 3-Star
Nos. 125856 910
rated
g) 250 kVA (Aluminium wound) Nos. 228340 1365
h) 250KVA BEE 3 star rated/Energy Efficient Nos. 292467 1365
h) 500 kVA (Aluminium wound) Nos. 361707 1819
11 kV G O S
a) 200 A Single break Set 6951 636
XXIV
b) 400 A Double break Set 15637 706
c) 200 A Single break vertical operation Set 10096 636
XXV 11 kV Solid Core HG Fuse Unit Set (3 Nos) 827 423
XXVI 11kV Class DOLO Cutouts Set (3 Nos) 4288 423
XXVI 11kV Class DOLO Cutouts(REC design) Set (3 Nos) 3396 423
XXVII Lightning Arresters
i) 9 kV , 5kA Metal oxide Type 3 Nos 2070 71
ii) 9 kV , 5kA Polymeric Type 3 Nos 3441 71
Transformer grounding
a) Pipe Type ( G.I. Pipe B -class with Strips
XXVIII bolt nuts and washers,salt, charcoal etc.,) Per Electrode 1277 573

Included in
b) Rod Type Set 2000
Material cost

Concreting with Material & Labour


Base concreting CC 1:4:8
a) Pole base 11/9.5/9/8 mtrs Pole supports 500x650x150 mm 229 -
b)Pole base 9 mtrs square pole 650x650x150 mm 298 -
c)Pole base 11 mtrs spun pole 1000x1000x150 mm 704 -
Pole concreting CC 1:2:4 (without coping) -
a) 9.5 Supports(pole concreting) 650x500x1850 mm 2792
a) 9M Supports(pole concreting) 650x500x1700 mm 2566 -
a) 9M Square Supports(pole concreting) 650X650x1700 mm 3214
XXIX b) 11M Tubular Supports(pole concreting) 1000x1000x2500 11378
c) 11 mtr PSC 650x500x2000 mm 2721
c) 7.5 / 8 M Supports 400x400x1500 mm 982 -
As per Drawing No.
a) Guy concreting with Boulders, Mud & Sand BESCOM/GM/CP/7 158
/dt: 24.10.07
Providing Coping for Poles with CC 1:2:4
- - -
(As per actuals)
a) 150mm around poles for a height of
300mm for RCC, PSC, PCC Poles/ I- each 444
Beem/Rail steel sections.
b)390mm all around the pole for an height of
each 1050
300mm for Spun Poles
Guy concreting in Marshy area:
XXIX
XXIX
a) Providing cement concrete 1:2:4 for
Anchor Rod in Marshy/Black Cotton Soil each 824
600x600x450mm
11 kV , 3 Core XLPE UG Cable (Flat
armoured)
XXX a) 3X95 Sq mm km 548860 35797
b) 3X240 Sq.mm km 1038890 37786
c)3X 400 Sq.mm km 1565000 39774
Fixing 3-phase LT Capacitor
housed in a enclosure with
XXXI
necessary Fuses, wiring, mounting
arrangement for
1 15/25 kVA DTC, 3 kVAr No. 725 382
2 63 kVA DTC, 9 kVAr No. 1131 382
3 100 kVA DTC, 18 kVAr No. 1933 450
4 250 kVA DTC, 27 kVAr No. 2958 525
5 500 kVA DTC, 54 kVAr No. 5083 549
Providing Electronic Trivector
Meters with associated CT's
XXXII Metering Box etc., on LT side of
Distribution Transformer Center
(including cost of energy meter)
1 for 15/25 kVA DTC with CT ratio 50/5A Set 7912 1145
2 for 50/63 kVA DTC with CT ratio 100/5A Set 7474 1145
3 for 100 kVA DTC with CT ratio 150/5A Set 7168 1145
4 for 250 kVA DTC with CT ratio 400/5 A Set 7330 1145
5 for 500 kVA DTC with CT ratio 800/5A Set 7465 1145
ABSTRACT OF COMMON SR 2016-17 COST DATA SHEETS
CSR 2016-17
Total cost Labour Charges
of Estimate only casual
Cost
(In Rs.) (In Rs.)
Data PARTICULARS Unit
Material + Labour
Sheet No.
(Both casual Labour
and Regular)
11 kV 3-Ph SC line with 40 mtrs span on 9 mtr
1 Km 298088 45973
supports using Rabbit conductor
11 kV 3-Ph SC line with 50 mtrs span on 9 mtr
2 Km 266555 39283
supports using Rabbit conductor
11 kV 3-Ph SC line with 50 mtrs span on 8 mtr
3 Km 240466 35107
supports using Rabbit conductor
11 kV 3-Ph SC line with 40 mtrs span on 9 mtr
4 Km 512054 54072
supports using coyote conductor
11 kV 3 Ph. SC Line and 3 phase - 4 wire LT line on 9.0
5 mtr supports with an average span of 50mtrs using Km 435455 59809
Rabbit Conductor for H.T. and WEASEL for L.T Lines

11 kV 3 Ph. SC Line and 3 phase - 4 wire LT line on 9.0


6 mtr supports with an average span of 40 mtrs using Km 544198 72369
Rabbit Conductor for H.T. and L.T Lines

3 Ph. 4 wire LT line on 8 mtr supports with 60 mtrs


7 Km 182277 29031
span using weasel Conductor (IP Set installations)
3 Ph. 4 wire LT line on 8 mtr Supports with 40 mtrs
8 Km 271584 39020
span using Rabbit Conductor
3 Ph. 4 wire LT line on 9 mtr Supports with 40 mtrs
9 Km 301278 44320
span using Rabbit Conductor
3 Ph. 5 wire LT line on 9.0 mtr supports Using Rabbit
conductor for phase and nutral and weasel for street
10 Km 356148 50319
light with a span of 40mtrs (For Cities, Towns and
Residential layouts)
3 Ph. 5 wire LT line with 8.0 mtr Supports Using Rabbit
11 Km 298281 39412
conductor with a span of 50 mtrs
3 Ph. 5 wire LT line with 8.0 mtr Supports Using
12 Km 213223 37702
Weasel with a span of 40 mtrs
L.T 3 Ph. 5 wire LT line with continuous earth wire on
9.0 mtr supports using RABBIT for phase, neutral and
13 weasel for street light control and 8 SWG G.I. wire for Km 379568 56395
continuous ground wire with 40 mtrs span in vertical
configuration
11 kV 3 ph. SC line on 9 mtr supports using Rabbit
14 conductor with 40 mtrs span with vertical configuration Km 511632 85797
in congested area
Providing 2 pole structrue at the tapping point using
15
RCC pole
a) 8 mtr RCC Per unit 46366 6408
b) 9 mtr RCC Per unit 49274 6586
16 Providing 3 Pole Structure using 9 Mtrs RCC Poles Per unit 42426 7671

17 Providing Metering to IP Set installations using SMC Box Nos 6992

Laying of 1km length of 11kV 3 core 95 Sq.mm XLPE


18 UG Cable using Horizontal drilling method a.Flat armour Km
b. Round Armour 1760646 977303
1886896 977303
Laying of 1km length of 11kV 3 core 95 Sq.mm XLPE
UG Cable using Conventional laying involving
19 excavation of soil Km
a. Flat armour 984811 207609
b. Round Armour 111106 207609
Laying of 1km length of 11kV 3 core 240 Sq.mm XLPE
UG Cable using Horizontal drilling method
20 Km 2250210 977402
a. Flat armour
b. Round Armour 2491270 977402
Laying of 1km length of 11kV 3 core 240 Sq.mm XLPE
UG Cable using Conventional laying involving
21 excavation of soil Km
a. Flat armour 1482385 209598
b. Round Armour 1723445 209598
Laying of 1km length of 11kV 3 core 400 Sq.mm XLPE
UG Cable using Horizontal drilling method
22 Km 2781044 977502
a. Flat armour
b. Round Armour 3172044 977502
Laying of 1km length of 11kV 3 core 400 Sq.mm XLPE
UG Cable using Conventional laying involving
23 excavation of soil Km
a. Flat armour 2015485 211586
b. Round Armour 2406485 211586
a) Erection of 3-ph, 11 kV/433V Distribution
Transformer center using 8mtr DPTs (For BEE 3 Star
Rated Transformers)
24 i) 25 kVA Per unit 125215 10523
25 ii) 63 kVA Per unit 171471 10728
iii) 100 kVA (with Distribution Box) Per unit 218184 11257
26
iv) 100kVA (with LT protection kit) Per unit 204584 11212

b) Erection of 3-ph, 11 kV/433V Distribution


Transformer center using 9mtr DPTs (For BEE Star
Rated Transformers)
24 a i) 25 kVA Per unit 129616 11078
25 a ii) 63 kVA Per unit 175872 11283
iii) 100 kVA (with Distribution Box) Per unit 222293 11679
26 a
iv) 100kVA (with LT protection kit) Per unit 208693 11634
Erection of 3-ph, 11 kV/433V 250 kVA Distribution
27 Per unit 378675 10675
Transformer center using 8mtr DPTs
Erection of 3-ph, 11 kV/433V 250 kVA Distribution
27 a Per unit 382506 10971
Transformer center using 9mtr DPTs
Erection of 25 kVA , BEE 3 Star Rated 11kV/433V,
28 Single pole mounted transformer centre on 9mtr RCC Per unit 104759 7952
pole Square section
Erection of 63 kVA, BEE 3 Star Rated11kV/433V,
29 Single pole mounted transformer centre on 9 mtr RCC Per unit 150810 8157
pole Square section
Erection of 100 kVA, BEE 3 Star Rated 11kV/433V,
Single pole mounted transformer centre on 9mtr RCC
30 pole Square section
a) With LT Distribution Box Per unit 196685 8430
b) With LT Protection Kit Per unit 183130 8385
Erection of 250 kVA, 11kV/433V, Single pole mounted
31 Distribution Transformer on 11mtrs spun pole with 3 Per unit 388095 13378
GOS system
Providing Compact RMU 11kV class VCB/SF6 Type
32
(1 Incomer+2 Breakers+1 Outgoing)
a Schenider Make Per unit
b ABB Make Per unit
c Seimens Make Per unit
d MEI Per unit
Providing Compact RMU 11kV class VCB/SF6 Type (1
33
Incomer+1Breakers+1 Outgoing)
a Schenider Make Per unit
b ABB Make Per unit
c Seimens Make Per unit Will be furnished
d MEI Per unit Will be furnished after after committee
Providing Compact RMU 11kV class VCB/SF6 Type committee report
34 report
(1 OD)
a Schenider Make Per unit
b ABB Make Per unit
c Seimens Make Per unit
d MEI Per unit
35 Providing Compact RMU 11kV class VCB/SF6 Type (1VL)
a Schenider Make Per unit
b ABB Make Per unit
c Seimens Make Per unit
d MEI Per unit
Running Single Circuit 11 kV 3 Phase Power line on 9
36 mtr RCC supports with average span of 30 mtrs using Km 956804 80892
3x95 Sqmm+1x70Sqmm Aerial Bunched Cables (ABC)
Running Single Circuit 1.1 kV 3 Phase 5 wire Power line
on 9 mtr RCC supports with average span of 40 mtrs
37 Km 728597 81519
using 3x95 +1x16 +1x70 Sqmm Aerial Bunched Cables
(ABC)
Installing RLMU for the existing 15/25 KVA Distribution
38 Per unit 53747 3483
Transformer Center
Installing RLMU for the existing 63 KVA Distribution
39 Per unit 58292 3483
Transformer Center
Installing RLMU for the existing 100 KVA Distribution
40 Per unit 65925 3483
Transformer Center
Erection of Compact Pre-fabricated Packaged Sub-
station 11kV / 433 V
a) With 100 kVA oil cooled transformer Per unit
b) With 250 kVA oil cooled transformer Per unit
c) With 500 kVA oil cooled transformer Per unit
d) With 750 kVA oil cooled transformer Per unit
41 Will be furnished
e) With 990 kVA oil cooled transformer Per unit Will be furnished after
after committee
f) With 100 kVA dry type transformer Per unit committee report
report
g) With 250 kVA dry type transformer Per unit
h) With 500 kVA dry type transformer Per unit
i) With 750 kVA dry type transformer Per unit
j) With 990 kVA dry type transformer Per unit
providing Electronic Trivector Meters with associated
42 CT's Metering Box etc., on LT side of Distribution
Transformer Center
i) 15/25 kVA (with meter) 7912 1145
a) Per unit
ii)15/25 kVA (without meter) 5662 514
i) 50/63 kVA (with meter) 7474 1145
b) Per unit
ii) 50/63 kVA (without meter) 5224 514
i) 100 kVA (with meter) 7168 1145
c) Per unit
ii) 100 kVA (without meter) 4918 514
i) 250 kVA (with meter) 7330 1145
d) Per unit
ii)250 kVA (without meter) 5080 514
i) 500 kVA (with meter) 7465 1145
e) Per unit
ii) 500 kVA (without meter) 5215 514
providing LT Capacitors to the Distribution Transformers
a) 3 kVAr for 15/25KVA DTCs Per unit 1107 382
43 b) 9 kVAr for 63KVA DTCs Per unit 1513 382
c) 18 kVAr for 100KVA DTCs Per unit 2383 450
d) 27 kVAr for 250KVA DTCs Per unit 3483 525
e) 54 kVAr for 300/500KVA DTCs Per unit 5632 549

For carrying out 1 to 2 poles works in respect of Ganga


44 Per Work 8829
Kalyana and Drinking Water Supply Works only.

For carrying out 3 to 5 poles works in respect of Ganga


45 Per Work 13949
Kalyana and Drinking Water Supply Works only.

For carrying out 1 to 4 (One to four) poles works in


46
respect of service main connection and E & I works only
a Works involving ONE pole Per Work 4238

b Works involving TWO poles Per Work 5650

c Works involving THREE poles Per Work 7063

d Works involving FOUR poles Per Work 8475

Consolidated Labour charges for shifting of conductor


terminations and all other fittings existing on the
47 deteriorated pole while replaceing termination(cut point) per pole 3000
poles(Does not include labour chages for releasing and
erection of pole)

Consolidated Labour charges for shifting of conductor


and all other fittings existing on the deteriorated pole
48 per pole 2200
while replaceing intermediate poles(Does not include
labour chages for releasing and erection of pole)

Standard Requirement of Materials for providing LT


49 Wiring for Distribution Transformer Centers of various Per Work
capacities
CDS for Distribution Line & Transformer works using 9mtrs PSCC poles of 300kg WL for Dead Ends
Anchor points & Structures

Running Single Circuit 11 kV, 3-Phase Power Line on


9.0 Mtr Supports with an Average Span of 50 Mtrs
50 Per unit 293994 45973
Using Rabbit ACSR Conductor and PSCC poles of 300
Kg WL for dead ends and DP structure

Running Single Circuit 11 kV, 3-Phase Power Line on


9.0 Mtr Supports with an Average Span of 40 Mtrs
51 Per unit 262461 39283
Using COYOTE ACSR conductor and PSCC poles of 300
Kg WL for dead ends and DP structure

Running Single Circuit 11 kV, 3-Phase Power Line on


9.0 Mtr Supports with an Average Span of 40 Mtrs
52 Per unit 505234 54072
Using COYOTE ACSR conductor and PSCC poles of 300
Kg WL for dead ends and DP structure

Running Single Circuit 11 kV 3 Phase Power Line and 3


Phase - 4 Wire Secondary Line on 9 Mtr Supports with
53 an Average Span of 50 Mtrs using RABBIT Conductor Per unit 431356 59809
for HT and WEASEL for LT Lines and using PSCC poles
of 300 Kg WL for dead ends and DP structure

Running Single Circuit 11 kV, 3-Phase Power Line & 3


Phase 4 Wire Secondary Line on 9.0 Mtr Supports with
54 an Average Span of 40 Mtrs Using RABBIT ACSR Per unit 540099 72369
conductor for HT & LT Lines and using PSCC poles of
300 Kg WL for dead ends and DP structure

Running LT, 3-Phase 4 Wire Power Line on 9.0 Mtr


Supports Using RABBIT ACSR Conductor with an
55 Per unit 299982 44320
Average Span of 40 Mtrs and using PSCC poles of 300
Kg WL for dead ends and DP structure

Running LT, 3-Phase 5 Wire for Power Line on 9.0 Mtr


Supports Using RABBIT ACSR Conductor for Phase and
Neutral, and WEASEL Conductor or Street Light with an
56 Per unit 348020 50319
Average Span of 40 Mtrs and using PSCC poles of 300
Kg WL for dead ends and Anchor Points (For Cities,
Towns and Residential Layouts)
Running LT, 3-Phase 5 Wire Power Line with
Continuous Earth Wire on 9.0 Mtr Supports Using
RABBIT ACSR for Phase and Neutral, and WEASEL
57 Conductor for Street Light and 8 SWG GI Wire for Per unit 371390 56395
Continuous Earth Wire with an Average Span of 40 Mtrs
in Vertical Configuration and using PSCC poles of 300
Kg WL for dead ends and Anchor Points

Running Single Circuit 11 kV, 3-phase Power Line on


9.0 Mtr Supports Using RABBIT ACSR Conductorand
58 using PSCC poles of 300 Kg WL for dead ends and Per unit 507543 85797
Anchor Points, With an Average Span of 40 Mtrs in
Vertical Configuration in Congested Areas

Providing 2 Pole Structrues at the Tapping Point Using


59 Per unit 46998 5488
9Mtrs PSCC Poles of 300.Kg WL
Erection of 3 Pole Structure With 9 Mtr PSCC Poles of
60 Per unit 38337 7671
300Kg WL
Erection of 3 Phase, 11kV/433V, 25kVA BEE – 3 Star
61 Rated Distribution Transformer Centre Using DPTS Per unit 115812 11078
With 9 Mtrs PSCC Pole 300Kg WL
Erection of 3 Phase, 11kV/433V, 63kVA BEE – 3 Star
62 Rated Distribution Transformer Centre Using DPTS Per unit 161863 11283
With 9 Mtrs PSCC Pole 300Kg WL
Erection of 3 Phase, 11kV/433V, 100kVA BEE – 3 Star
63(a) Rated Distribution Transformer Centre Using DPTS Per unit 194333 11634
With 9 Mtrs PSCC Pole 300Kg WL

Erection of 3 Phase, 11kV/433V, 100kVA BEE – 3 Star


63 (b) Rated Distribution Transformer Centre Using DPTS Per unit 207888 11679
With 9 Mtrs PSCC Pole 300Kg WL

Erection of 3 Phase, 11kV/433V, 250kVA BEE – 3 Star


64 Rated Distribution Transformer Centre Using DPTS Per unit 368809 10971
With 9 Mtrs PSCC Pole 300Kg WL
Erection of 3 Phase, 11kV/433V, 25kVA BEE 3 Star
65 Rated Single Pole Mounted Transformer Centre on 9 Per unit 101410 7952
Mtrs PSCC Pole 300kg WL
Erection of 3 Phase, 11kV/433V, 63kVA BEE 3 Star
66 Rated Single Pole Mounted Transformer Centre on 9 Per unit 147461 8157
Mtrs PSCC Pole 300kg WL

Erection of 3 Phase, 11kV/433V, 100kVA BEE 3 Star


67(a) Rated Single Pole Mounted Transformer Centre on 9 Per unit 193336 8430
Mtrs PSCC Pole 300kg WL (with LT Distribution Box )

Erection of 3 Phase, 11kV/433V, 100kVA BEE 3 Star


67(b) Rated Single Pole Mounted Transformer Centre on 9 Per unit 179781 8385
Mtrs PSCC Pole 300kg WL (with LT Protection KIT)

Running Single Circuit 11kV, 3 Phase Power Line on 9


Mtr Supports with an Average Span of 30 Mtrs Using
68 3x95 Sqmm + 1x70 Sqmm Aerial Bunched Cables (ABC) Per unit 943174 80892
using 9mtr PSCC pole of 300kg WL for Dead Ends and
Anchor Points

Running Single Circuit 1.1 kV 3 Phase 5 Wire Power


Line on 9 Mtr Supports with Average Span of 40 Mtrs
69 Using 3x95 + 1x16 + 1x70 Sqmm Aerial Bunched Per unit 714967 81519
Cables (ABC) using 9mtr PSCC pole of 300kg WL for
Dead Ends and Anchor Points
COST DATA SHEET - 23
For laying of 1 Km Length of 11kV, 3 Core, 400 Sqmm XLPE UG Cable
Using Conventional Laying with Excavation in Soil

Material cost
SL.
Particulars Unit Qty
No
Rate Amt

1 11kV Class 3x400 Sqmm XLPE UG Cable (Flat Armoured) Km 1 1565000 1565000
11kV Class 3x400 Sqmm XLPE UG Cable (Round
2 Km 1 1956000 1956000
Armoured)
Straight Through Jointing Kits HS Type suitable for
3 Nos 3 8050 24150
3x400 Sqmm Cable
Cable Termination Kit Outdoor HS Type Suitable for
4 Per Kit 1 3940 3940
3x400 Sqmm Cable
Cable Termination Kit Indoor HS Type Suitable for 3x400
5 Per Kit 1 3540 3540
Sqmm Cable
4000 /
6 Cable Covering Tiles 250x125x40 mm or 125x125x40 mm Nos 10/5 40000
8000

7 Sand Cmt 60 1700 102000

8 RCC Hume Pipe, 2000mm Long, 150mm Dia Nos 30 300 9000

9 Collars for RCC Hume Pipe Nos 30 80 2400

10 GI Pipe, 150 mm Dia for drain crossing, cable raising etc., Mtrs 8 1144 9152

11 Route and Joint indicating stones Nos 20 120 2400

Total (Flat Armoured) 1761582


Total (Round Armoured) 2152582

10 Labour charges
a) Cable trench excavation, 1000x0.6x1=600, Ordinary
Cmt 600 205 123000
soil
b) Laying of cable in trench Km 1 39774 39774
c) Refilling and consolidation Cmt 550 45 24750
d) Making of straight through joints Nos 3 1695 5085
e) Making of cable terminations Nos 2 1554 3108
f) Covering the cable with tiles Km 1 2603 2603

g) Spreading Sand and forming with Sand round the cable Km 1 9146 9146

h) Laying of RCC Hume pipes Mtrs 60 40 2400


i) Laying of GI Pipe Mtrs 8 45 360
j) Laying of Route and Joint indicating stones Nos 20 68 1360

Total Labour Charges

a) Casual 211586

b) Regular 42317

Total Cost/Km in Rs. (Flat Armoured) 2015485


Total Cost/Km in Rs. (Round Armoured) 2406485
As per prevailing rates prescribed by
11 Add rates for Reinstatements of Roads local bodies (Corporations/
Municipalities/VPs)
NOTE
While preparing estimates for turnkey / total tunkey projects please refer to Sl. No. ......... of General
1)
Guidelines vide a to .... in Page No. ...........

When multiples cables have to be laid in the common trench the following excavation is to be followed: a)
2) 0.75 Mtrs x 1 Mtrs for 2 cables. b) 1 Mtr x 1 Mtr for 3 cables. c) 1.25 Mtr x 1 Mtr for 4 nos. of cables and
so on (As per Ltr No. BESCOM/BC-14/F-45

Where cables are laid using trenchless technology, there may be a necessity to lay the cable in open
3) trench excavation. Hence provisionshall be made for both in the estimate and the bills shall be paid as
per actual inventory taken.
COST DATA SHEET - 22
For laying of 1 Km Length of 11kV, 3 Core, 400 Sqmm XLPE UG Cable
Using Horizontal Drilling

Material cost
SL.
Particulars Unit Qty
No
Rate Amt

Material Cost

1 11kV Class 3x400 Sqmm XLPE UG Cable (Flat Armoured) Km 1 1565000 1565000

11kV Class 3x400 Sqmm XLPE UG Cable (Round


2 Km 1 1956000 1956000
Armoured)

Straight Through Jointing Kits HS Type suitable for 400


3 Nos 3 8050 24150
Sqmm Cable

Cable Termination Kit Outdoor HS Type Suitable for 400


4 Per Kit 1 3940 3940
Sqmm Cable
Cable Termination Kit Indoor HS Type Suitable for 400
5 Per Kit 1 3540 3540
Sqmm Cable

6 RCC Hume Pipe, 2000 mm Long, 150 mm Dia Nos 3 300 900

7 Collars for RCC Hume pipe Nos 2 80 160

8 GI Pipe, 150 mm Dia for drain crossing, cable raising etc., Mtrs 8 1144 9152

9 Route and Joint Indicating Stones Nos 10 120 1200

Total (Flat Armoured) 1608042


Total (Round Armoured) 1999042
10 Labour charges

a) Laying of cable in trench in wherever necessary Mtrs 50 39774 1989


b) Labour chargers for horizontal drilling with 6 inches
bore size
i) Without HDPE Pipe Rmtr 50 706 35300

ii) With HDPE pipe Rmtr 900 1031 927900


c) Making of straight through joints Nos 3 1695 5085

d) Making of cable terminations Nos 2 1554 3108

e) Laying of RCC Hume pipes Nos 60 40 2400

f) Laying of GI Pipe Mtr 8 45 360

gj) Laying of Route and Joint indicating stones Nos 20 68 1360

Total Labour Charges 977502

a) Casual 977502

b) Regular 195500

Total Cost/Km in Rs. (Flat Armoured) 2781044


Total Cost/Km in Rs. (Round Armoured) 3172044
As per prevailing rates prescribed by
11 Add rates for Reinstatements of Roads local bodies
(Corporations/Municipalities/VPs)
NOTE

While preparing estimates for turnkey / total tunkey projects please refer to Sl. No. ......... of General
1)
Guidelines vide a to .... in Page No. ...........

When multiples cables have to be laid in the common trench the following excavation is to be followed: a)
2) 0.75 Mtrs x 1 Mtrs for 2 cables. b) 1 Mtr x 1 Mtr for 3 cables. c) 1.25 Mtr x 1 Mtr for 4 nos. of cables and
so on (As per Ltr No. BESCOM/BC-14/F-45

Where cables are laid using trenchless technology, there may be a necessity to lay the cable in open
3)
trench excavation. Hence provisionshall be made for both in the estimate and the bills shall be paid as
per actual inventory taken.
COST DATA SHEET - 21
For Laying of 1 Km Length of 11kV, 3 Core, 240 Sqmm XLPE UG Cable
Using Conventional Laying with Excavation in Soil
Material cost
SL.
Particulars Unit Qty
No Rate Amt

1 11kV Class 3x240 Sqmm XLPE UG Cable (Flat Armoured) Km 1 1038890 1038890
11kV Class 3x240 Sqmm XLPE UG Cable (Round
2 Km 1 1279950 1279950
Armoured)
Straight Through Jointing Kits HS Type suitable for
2 Nos 3 6555 19665
3x240 Sqmm Cable
Cable termination kit Outdoor HS Type Suitable for
3 Per Kit 1 3910 3910
3x240 Sqmm Cable
Cable termination kit Indoor HS Type Suitable for 3x240
Per Kit 1 3450 3450
Sqmm Cable
4000 /
4 Cable Covering Tiles 250x125x40 mm or 125x125x40 mm Nos 10/5 40000
8000

5 Sand Cmt 60 1700 102000

6 RCC Hume pipe, 2000 mm Long, 150 mm Dia Nos 30 300 9000
7 Collars for RCC Hume Pipe Nos 30 80 2400

8 GI Pipe, 100 mm Dia for drain crossing, cable raising etc., Mtrs 8 1144 9152

9 Route and Joint Indicating Stones Nos 20 120 2400

Total (Flat Armoured) 1230867

Total (Round Armoured) 1471927

10 Labour charges
a) Cable trench excavation, 1000x0.6x1=600, Ordinary
Cmt 600 205 123000
soil
b) Laying of cable in trench Km 1 37786 37786

c) Refilling and consolidation Cmt 550 45 24750

d) Making of straight through joints Nos 3 1695 5085

e) Making of cable terminations Nos 2 1554 3108


f) Covering the cable with tiles Km 1 2603 2603

g) Spreading Sand and forming with Sand round the cable Km 1 9146 9146

h) Laying of RCC Hume pipes Mtr 60 40 2400

i) Laying of GI Pipe Mtr 8 45 360

j) Laying of Route and Joint indicating stones Nos 20 68 1360

Total Labour Charges

a) Casual 209598

b) Regular 41920

Total Cost/Km in Rs. (Flat Armoured) 1482385


Total Cost/Km in Rs. (Round Armoured) 1723445

As per prevailing rates prescribed by local bodies


11 Add Rates for Reinstatements of Roads
(Corporations/Municipalities/VPS as applicable)

NOTE
While preparing estimates for turnkey / total tunkey projects please refer to Sl. No. ......... of General
1)
Guidelines vide a to .... in Page No. ...........

When multiples cables have to be laid in the common trench the following excavation is to be followed: a)
2) 0.75 Mtrs x 1 Mtrs for 2 cables. b) 1 Mtr x 1 Mtr for 3 cables. c) 1.25 Mtr x 1 Mtr for 4 nos. of cables and
so on (As per Ltr No. BESCOM/BC-14/F-45

Where cables are laid using trenchless technology, there may be a necessity to lay the cable in open
3) trench excavation. Hence provisionshall be made for both in the estimate and the bills shall be paid as
per actual inventory taken.
COST DATA SHEET - 20

For Laying of 1 Km Length of 11kV, 3 Core, 240 Sqmm XLPE UG Cable


Using Horizontal Drilling

Material cost
SL.
Particulars Unit Qty
No
Rate Amt

Material Cost

11kV Class 3x240 Sqmm XLPE UG Cable (Flat


1 Km 1 1038890 1038890
Armoured)
11kV Class 3x240 Sqmm XLPE UG Cable (Round
2 Km 1 1279950 1279950
Armoured)
Straight Through Jointing Kits HS Type suitable for
3 Nos 3 6555 19665
240 Sqmm Cable
Cable Termination Kit Outdoor/Indoor HS Type
4 Per Kit 1 3910 3910
Suitable for 240 Sqmm Cable
Cable Termination Kit Outdoor/Indoor HS Type
Per Kit 1 3450 3450
Suitable for 240 Sqmm Cable

5 RCC Hume Pipe, 2000 mm Long, 150 mm Dia Nos 3 300 900

6 Collars for RCC Hume pipe Nos 2 80 160


GI Pipe, 100 mm Dia for drain crossing, cable raising
7 Mtrs 8 1144 9152
etc.,
8 Route and Joint Indicating Stones Nos 10 120 1200

Total (Flat Armoured) 1077327

Total (Round Armoured) 1318387

9 Labour charges

a) Laying of cable in trench in wherever necessary Mtrs 50 37786 1889

b) Labour chargers for horizontal drilling with 6


inches bore size
i) Without HDPE Pipe Rmtr 50 706 35300

ii) With HDPE pipe Rmtr 900 1031 927900

c) Making of straight through joints Nos 3 1695 5085

d) Making of cable terminations Nos 2 1554 3108

e) Laying of RCC Hume pipes Nos 60 40 2400

f) Laying of GI Pipe Mtrs 8 45 360

g) Laying of Route and Joint indicating stones Nos 20 68 1360

Total Labour Charges 977402


a) Casual 977402
b) Regular 195480
Total Cost/Km in Rs. (Flat Armoured) 2250210

Total Cost/Km in Rs. (Round Armoured) 2491270


As per prevailing rates prescribed by local bodies
10 Add Rates for Reinstatements of Roads (Corporations/Municipalities/
VPS as applicable)
NOTE

While preparing estimates for turnkey / total tunkey projects please refer to Sl. No. ......... of
1)
General Guidelines vide a to .... in Page No. ...........

When multiples cables have to be laid in the common trench the following excavation is to be
2) followed: a) 0.75 Mtrs x 1 Mtrs for 2 cables. b) 1 Mtr x 1 Mtr for 3 cables. c) 1.25 Mtr x 1 Mtr for 4
nos. of cables and so on (As per Ltr No. BESCOM/BC-14/F-45

Where cables are laid using trenchless technology, there may be a necessity to lay the cable in
3) open trench excavation. Hence provision shall be made for both in the estimate and the bills
shall be paid as per actual inventory taken.
COST DATA SHEET - 19
For Laying of 1 Km Length of 11kV, 3 Core, 95 Sqmm XLPE UG Cable
Using Conventional Laying with Excavation of Soil

SL. Material cost


Particulars Unit Qty
No
Rate Amt
Material Cost
11kV Class 3x95 Sqmm XLPE UG Cable (Flat
1 Km 1 548860 548860
Armoured)
11kV Class 3x95 Sqmm XLPE UG Cable (Round
2 Km 1 675110 675110
Armoured)
Straight Through Jointing Kits HS Type suitable for 95
3 Nos 3 5375 16125
Sqmm Cable
Cable Termination Kit Outdoor HS Type Suitable for 95
4 Per Kit 1 2990 2990
Sqmm Cable
Cable Termination Kit Indoor HS Type Suitable for 95
Per Kit 1 2753 2753
Sqmm Cable
Cable covering tiles 250x125x40 mm or 125x125x40 4000/
5 Nos 10/5 40000
mm 8000
6 Sand Cmt 60 1700 102000

7 RCC Hume Pipe, 2000 mm Long, 150 mm Dia Nos 30 300 9000

8 Collars for RCC Hume Pipe Nos 30 80 2400


GI Pipe, 100 mm Dia for drain crossing, cable raising
9 Mtrs 8 1144 9152
etc.,

10 Route and Joint Indicating Stones Nos 20 120 2400

Total (Flat Armoured) 735680

Total (Round Armoured) 861930

11 Labour charges

a) Cable trench excavation, 1000x0.6x1=600, Ordinary


Cmt 600 205 123000
soil

b) Laying of cable in trench km 1 35797 35797


c) Refilling and consolidation Cmt 550 45 24750
d) Making of straight through joints No 3 1695 5085
e) Making of cable terminations No 2 1554 3108
f) Covering the cable with tiles km 1 2603 2603
g) Spreading Sand and forming with Sand round the
km 1 9146 9146
cable
h) Laying of RCC Hume pipes mtr 60 40 2400
i) Laying of GI Pipe mtr 8 45 360
j) Laying of Route and Joint indicating stones No 20 68 1360
Total Labour Charges 207609
a) Casual 207609
b) Regular 41522
Total Cost/Km in Rs. (Flat Armoured) 984811

Total Cost/Km in Rs. (Round Armoured) 1111061


As per prevailing rates prescribed by local bodies
12 Add Rates for Reinstatements of Roads (Corporations/Municipalities/
VPS as applicable)
NOTE

While preparing estimates for turnkey / total tunkey projects please refer to Sl. No. ......... of General
1)
Guidelines vide a to .... in Page No. ...........

When multiples cables have to be laid in the common trench the following excavation is to be
2) followed: a) 0.75 Mtrs x 1 Mtrs for 2 cables. b) 1 Mtr x 1 Mtr for 3 cables. c) 1.25 Mtr x 1 Mtr for 4
nos. of cables and so on (As per Ltr No. BESCOM/BC-14/F-45

Where cables are laid using trenchless technology, there may be a necessity to lay the cable in open
3)
trench excavation. Hence provision shall be made for both in the estimate and the bills shall be paid
as per actual inventory taken.
COST DATA SHEET - 18
For laying of 1 Km Length of 11kV, 3 Core 95 Sqmm XLPE UG Cable
Using Horizontal Drilling

Material cost
SL.
Particulars Unit Qty
No
Rate Amt

Material Cost

1 11kV Class 3x95 Sqmm XLPE UG Cable (Flat Armoured) Km 1 548860 548860

11kV Class 3x95 Sqmm XLPE UG Cable (Round


2 Km 1 675110 675110
Armoured)

Straight Through Jointing Kits HS Type suitable for 95


3 Nos 3 5375 16125
Sqmm Cable
Cable Termination Kit Outdoor HS Type suitable for 95
4 Per Kit 2 2990 5980
Sqmm Cable
Cable Termination Kit Indoor HS Type suitable for 95
Per Kit 2 2753 5506
Sqmm Cable

5 RCC Hume Pipe, 2000 mm Long, 150 mm Dia Nos 3 300 900

6 Collars for RCC Hume Pipe Nos 2 80 160

7 GI Pipe, 100 mm Dia for drain crossing, cable raising etc., Mtrs 8 1144 9152

8 Route and Joint Indicating Stones Nos 10 120 1200

Total (Flat Armoured) 587883

Total (Round Armoured) 714133

9 Labour charges

a) Laying of cable in trench in wherever necessary Mtrs 50 35797 1790

b) Labour chargers for horizontal drilling with 6 inches


bore size

i) Without HDPE Pipe Rmtr 50 706 35300

ii) With HDPE pipe Rmtr 900 1031 927900

c) Making of straight through joints Nos 3 1695 5085


d) Making of cable terminations Nos 2 1554 3108

e) Laying of RCC Hume pipes Nos 60 40 2400


f) Laying of GI Pipe Mtrs 8 45 360

g) Laying of Route and Joint indicating stones Nos 20 68 1360

Total Labour Charges 977303

a) Casual 977303
b) Regular 195461
Total Cost/Km in Rs. (Flat Armoured) 1760646

Total Cost/Km in Rs. (Round Armoured) 1886896

As per prevailing rates prescribed by local bodies


10 Add Rates for Reinstatements of Roads (Corporations/Municipalities/
VPS as applicable)
Note:
While preparing estimates for turnkey/total tunkey projects please refer to Sl. No. ......... of General
1)
Guidelines vide a to .... in Page No. ...........

When multiples cables have to be laid in the common trench the following excavation is to be followed: a)
2) 0.75 Mtrs x 1 Mtrs for 2 cables. b) 1 Mtr x 1 Mtr for 3 cables. c) 1.25 Mtr x 1 Mtr for 4 nos. of cables and
so on (As per Ltr No. BESCOM/BC-14/F-45

Where cables are laid using trenchless technology, there may be a necessity to lay the cable in open
3) trench excavation. Hence provision shall be made for both in the estimate and the bills shall be paid as
per actual inventory taken.
COST DATA SHEET -17
Estimate for Providing Metering to IP Set Installations Using SMC Box

SL. Material cost


Paritculars Unit Qty
No
Rate Amt

Whole Current Meter 10-60A 3 Phase (Static Meter)


1 Nos 1 3000 3000
Class-1 Accuracy

2 SMC Meter Housing box with 6 mm hylam sheet Nos 1 2100 2100

16 Sqmm Alluminium Single Core/Multi Core of


4 Set 1 368 368
Grade 650/1100V (16 Mts)

5 PVC Pipe of 2 mm Thick 40mm Dia Mtrs 4 50 200

6 3 Nos Porcelain Cutouts 60A with Wooden Plank Set 1 474 474

Misc materials such as water tight bends and


7 LS LS - 150
aluminium pins/bullets

8 Labour Charges (Lump sum) LS LS - 700

Total 6992
COST DATA SHEET -16

Erection of 3 Pole Structure With 9 Mtr RCC Pole

SL.
Paritculars Unit Qty Material cost Labour Cost
No

Part-A: LINES Rate Amt Rate Amt

3 Pole Structure complete using 9 Mtrs RCC Poles (


1 Set 1 27446 27446 6271 6271
Including Cost of Poles)

2 Spiral Earth Electrode Nos 3 207 621 55 165

3 Guy Set With No.15 Strain Insulator Complete Sets 3 742 2226 354 1062

4 45kN Disc Insulators Nos 6 290 1740 0 0

5 11kV Pin Insulators with GI Pins Nos 3 94 282 0 0

6 Concrete for Guy set (without cement) Nos 3 158 474 0 0

Caution/Danger Board as per Drawing No.


7 Nos 2 120 240 49 98
BESCOM/GM/CP/40/Dt: 24.10.07

Anti Climbing Device (12mtrs/1Kg GI Barbed Wire)


8 Kgs 3 64 192 25 75
Lumpsum

9 Total Material cost 33221

10 Labour Charges

a) Casual 7671

b) Regular 1534

Total Cost/Unit in Rs. 42426

Note:
1) RCC Poles shall be used for dead ends, DP structure and PSC poles for intermediate supports

2) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET -15
Providing 2 Pole Structrue at the Tapping Point Using RCC Poles

SL.
Paritculars Unit Qty Material cost Labour Cost
No

Part-A: LINES Rate Amt Rate Amt

RCC DP Structure using 9 Mtrs RCC Pole with


1 Set 1 15910 15910 3252 3252
WL 145 kg
RCC DP Structure using 8 Mtrs RCC Pole with WL
2 Set 1 12730 12730 3104 3104
115 kg
3 45kN Disc Insulators Nos 6 290 1740 0 0

4 Guy Set Complete Sets 2 742 1484 354 708

5 Spiral Earth Electrode Nos 2 207 414 55 110

6 Concrete for Guy Set (without Cement) Nos 2 158 316 0 0

Caution/Danger Board as per Drawing No.


7 No 1 120 120 49 48
BESCOM/GM/CP/40/Dt: 24.10.07

Anti Climbing Device (12mtrs/1Kg GI Barbed Wire)


8 Kgs 2 64 128 25 50
Lumpsum

Total Part A

Using 8 Mtrs RCC Pole 16932 4020

Using 9 Mtrs RCC Pole 20112 4168

Part-B: SWITCH GEAR

10 11kV 400A D/B GOS Set 1 15637 15637 706 706

11 H-Frame for mounting GOS No 1 2895 2895 191 191

12 DOLO Cut Out Set/3 Nos 1 4494 4494 423 423

Total Part B 23026 1320

13 Material Cost using 8 Mtrs RCC Pole (A+B) 39958

Labour Charges

a) Casual 5340

b) Regular 1068

14 Material cost using 9 Mtrs RCC Pole (A+B) 43138

Labour Charges

a) Casual 5488

b) Regular 1098

15 Total Cost of Estimate using 8 Mtrs RCC Pole 46366 6408

Total Cost of Estimate using 9 Mtrs RCC Pole 49724 6586

Note: 1) RCC Poles shall be used for dead ends, DP structure and PSC poles for intermediate supports

2) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 14
Running Single Circuit 11 kV, 3-phase Power Line on 9.0 Mtr Supports Using RABBIT ACSR Conductor With an Average Span of
40 Mtrs in Vertical Configuration in Congested Areas

Material cost Labour Cost


SL.
Particulars Unit Qty
No
Rate Amt Rate Amt

RCC Pole - 9 Mtrs Long, 145 kg WL (for Deadend,


1 Nos 1 5941 5941 1060 1060
Anchor points)

PSC Pole -9 Mtrs Long, 200 kg WL (for Intermediate


2 Nos 23 3401 78223 1060 24380
Poles)

3 DP Structure using 9 Mtrs RCC poles Set 1 15910 15910 3252 3252

Special cross arm with cross arm for EG Stirrups,


4 Sets 23 1122 25806 316 7268
braces, clamps, bolts nuts and washers complete

5 11kV ceramic Pin Insulators with GI Pins Nos 69 94 6486 0 0

6 45kN Disc Insulators Nos 6 290 1740 0 0

7 Guy Set Complete Sets 9 742 6678 354 3186

8 Rabbit ACSR Conductor Kms 3.045 33676 102543 2608 7941

9 Spiral Earth Electrode Nos 26 207 5382 55 1430

10 EG Stirrups with GI wire lacing Set of 2 No's 370 424 156880 99 36630

11 Concreting Materials for guy sets (Without Cement) Nos 9 158 1422 0 0

Anti Climbing Device (12mtrs/1Kg GI Barbed Wire)


12 Kgs 26 64 1664 25 650
Lumpsum

Total 408675 85797

13 Labour charges

a) Casual 85797

b) Regular 17159

Total Cost/Km in Rs. 511632

Note: Item 4 includes, the following


a) Special cross arms 50x50x6 mm MS 0.715 mtr long 3-Nos
b) Support piece for fixing EG stirrup 50x50x6 mm MS Angle 0.865 mtr long - 1 No
c) Brace 50x50x6 mm MS Angle 0.850 mtr long - 1 No
d) 50x6 mm Flat 1.8 mtr, long - 1No
e) RCC Pole Clamps - 5 Nos
f) Cross Arm for fixing EG Stirrup - 1 No

1) RCC Poles shall be used for dead ends, DP structure and PSC poles for intermediate supports

2) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 13
Running LT, 3-Phase 5 Wire Power Line with Continuous Earth Wire on 9.0 Mtr Supports Using RABBIT ACSR for Phase and
Neutral, and WEASEL Conductor for Street Light and 8 SWG GI Wire for Continuous Earth Wire with an Average Span of 40 Mtrs
in Vertical Configuration

SL. Material cost Labour Cost


Particulars Unit Qty
No Rate Amt Rate Amt

RCC Pole - 9 Mtrs Long, 145 kg WL (for Deadend,


1 Nos 6 5941 35646 1060 6360
Anchor points)

PSC Pole -9 Mtrs Long, 200 kg WL (for Intermediate


2 Nos 19 3401 64619 1060 20140
Poles)
Fabricated Vertical Cross Arms with pole, clamps, bolts,
3 Sets 30 626 18780 287 8610
nuts and washers
4 1.1kV Pin Insulators with GI Pins Nos 100 38 3800 0 0
5 No.8 Strain Insulators Nos 50 14 700 0 0

6 Guy Set Complete Sets 12 723 8676 354 4248

7 Rabbit ACSR Conductor Kms 4.06 33676 136725 2608 10588

8 Weasel ACSR Conductor Kms 1.015 20100 20402 1913 1942

1.015
9 No.8 SWG GI wire for continuous earth wire Kms 54.674 5631 1913 1942
(103 kgs)

10 8 SWG GI wire for guard loops Kgs 26 54.674 1422 0 0

11 Spiral Earth Electrode Nos 25 207 5175 55 1375

12 Concreting Materials for guy sets (Without Cement) Nos 8 140 1120 0 0

SMC Street Lighting Metering Box with Automatic


13 Control Swith, Contactors with Single Phase 5-30 Amps Nos 1 6500 6500 565 565
meter & 50/5A CT including wiring
14 PVC Pipe 40 mm Dia Mtrs 6 50 300 0 0
PVC Insulated wire 25 Sqmm Single Core Multi
15 Mtrs 25 32 800 0 0
Stranded

Anti Climbing Device (12mtrs/1Kg GI Barbed Wire)


16 Kgs 25 64 1600 25 625
Lumpsum

Total 311895 56395

17 Labour charges

a) Casual 56395

b) Regular 11279

Total Cost/Km in Rs. 379568

Note: 1) RCC Poles shall be used for dead ends, DP structure and PSC poles for intermediate supports

2) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 12
Running LT, Single Phase 3 Wire Power Line on 8.0 Mtr Supports with an Average Span of 40 Mtrs
Using WEASEL ACSR Conductor

SL. Material cost Labour Cost


Particulars Unit Qty
No Rate Amt Rate Amt

RCC Pole - 8 Mtrs Long, 115 kg WL (for Deadend,


1 Nos 5 4351 21755 848 4240
Anchor points)

PCC Pole - 8 Mtrs Long, 200 kg WL (for Intermediate


2 Nos 20 2495 49900 848 16960
Poles)

LT 4 Pin cross arms, with pole clamps, bolts, nuts and


3 Set 5 263 1315 96 480
washers (for RCC poles)

LT 4 Pin cross arms, with pole clamps, bolts, nuts and


4 Sets 25 255 6375 96 2400
washers (for PCC poles)

LT 2 Pin cross arms, with pole clamps, bolts, nuts (for


5 Set 5 162 810 96 480
RCC poles)
LT 2 Pin cross arms, with pole clamps, bolts, nuts (for
6 Sets 20 154 3080 96 1920
PCC poles)

7 1.1kV Pin Insulators with GI Pins Nos 48 38 1824 0 0

8 No.8 Strain Insulators Nos 21 14 294 0 0

9 Guy Set Complete Sets 8 723 5784 354 2832

10 Weasel ACSR Conductor Kms 3.045 20100 61205 1913 5825

11 Spiral Earth Electrode Nos 25 207 5175 55 1375

12 Concreting Materials for guy sets (without cement) Nos 8 158 1264 0 0

SMC Street Lighting Metering Box with Automatic


13 Control Swith, Contactors with Single Phase 5-30 Amps Nos 1 6500 6500 565 565
meter & 50/5A CT including wiring

14 PVC Pipe 40 mm Dia Mtrs 6 50 300 0 0

PVC Insulated wire 25 Sqmm Single Core Multi


15 Mtrs 25 32 800 0 0
Stranded
Anti Climbing Device (12mtrs/1Kg GI Barbed Wire)
16 Kgs 25 64 1600 25 625
Lumpsum

Total 167981 37702

17 Labour charges

a) Casual 37702

b) Regular 7540

Total Cost/Km in Rs. 213223

Note: 1) RCC Poles shall be used for dead ends, DP structure and PSC poles for intermediate supports

2) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 11
Running LT, 3 Phase 5 Wire for Power Line on 8.0 Mtr Supports Using RABBIT ACSR Conductor for Phase and Neutral, and
WEASEL Conductor for Street Light with an Average Span of 50 mtrs

Material cost Labour Cost


SL.
Particulars Unit Qty
No Rate Amt Rate Amt

RCC Pole - 8 Mtrs Long, 115 kg WL (for Deadend,


1 Nos 5 4351 21755 848 4240
Anchor points.)

PCC Pole - 8 Mtrs Long, 200 kg WL (for Intermediate


2 Nos 15 2495 37425 848 12720
Poles)
LT 4 Pin cross arms, with pole clamps, bolts, nuts and
3 Set 5 263 1315 96 480
washers (for RCC poles)

LT 4 Pin cross arms, with pole clamps, bolts, nuts and


4 Sets 20 255 5100 96 1920
washers (for PCC poles)
LT 2 Pin cross arms, with pole clamps, bolts, nuts (for
5 Set 5 162 810 96 480
RCC poles)
LT 2 Pin cross arms, with pole clamps, bolts, nuts (for
6 Sets 20 154 3080 96 1920
PCC poles)
7 1.1kV Pin Insulators with GI Pins Nos 95 38 3610 0 0

8 No.8 Strain Insulators Nos 50 14 700 0 0

9 Guy Set Complete Sets 8 723 5784 354 2832

10 Rabbit ACSR Conductor Kms 4.06 33636 136562 2608 10588

11 Weasel ACSR Conductor Kms 1.015 20100 20402 1913 1942

12 Spiral Earth Electrode Nos 20 207 4140 55 1100

13 Concreting Materials for guy sets (Without Cement) Nos 8 158 1264 0 0

SMC Street Lighting Metering Box with Automatic


14 Control Swith, Contactors with Single Phase 5-30 Amps Nos 1 6500 6500 565 565
meter & 50/5A CT including wiring

15 PVC Pipe 40 mm Dia Mtrs 6 50 300 0 0

PVC Insulated wire 25 Sqmm Single Core Multi


16 Mtrs 20 32 640 0 0
Stranded

Anti Climbing Device (12mtrs/1Kg GI Barbed Wire)


17 Kgs 25 64 1600 25 625
Lumpsum

Total 250987 39412

Note: The no. of RCC poles and PCC poles have to be used as per field conditions and hence estimates have to be prepared
accordingly.

18 Labour charges

a) Casual 39412

b) Regular 7882

Total Cost/Km in Rs. 298281

1) RCC Poles shall be used for dead ends, DP structure and PSC poles for intermediate supports
Note:

2) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 10
Running LT, 3-Phase 5 Wire for Power Line on 9.0 Mtr Supports Using RABBIT ACSR Conductor for Phase and Neutral, and
WEASEL Conductor or Street Light with an Average Span of 40 Mtrs (For Cities, Towns and Residential Layouts)

Material cost Labour Cost


SL.
Particulars Unit Qty
No
Rate Amt Rate Amt

RCC Pole - 9 Mtrs Long, 145 kg WL (for Deadend,


1 Nos 6 5941 35646 1060 6360
Anchor points)
PSC Pole - 9 Mtrs Long, 200 kg WL (for Intermediate
2 Nos 19 3401 64619 1060 20140
Poles)
LT 4 Pin cross arms, with pole clamps, bolts, nuts and
3 Sets 7 263 1841 96 672
washers (for RCC poles)
LT 4 Pin cross arms, with pole clamps, bolts, nuts and
4 Sets 22 255 5610 96 2112
washers (for PSC poles)
LT 2 Pin cross arms, with pole clamps, bolts, nuts (for
5 Sets 7 162 1134 96 672
RCC poles)

LT 2 Pin cross arms, with pole clamps, bolts, nuts (for


6 Sets 18 154 2772 96 1728
PSC poles)

7 1.1kV Pin Insulators with GI Pins Nos 95 38 3610 0 0

8 No.8 Strain Insulators Nos 50 14 700 0 0

9 Guy Set Complete Sets 10 723 7230 354 3540

10 Rabbit ACSR Conductor Kms 4.06 33636 136562 2608 10588

11 Weasel ACSR Conductor Kms 1.015 20100 20402 1913 1942


12 Spiral Earth Electrode Nos 25 207 5175 55 1375

13 Concreting Materials for guy sets (without Cement) No's 8 158 1264 0 0

SMC Street Lighting Metering Box with Automatic


14 Control Swith, Contactors with Single Phase 5-30 Amps No's 1 6500 6500 565 565
meter & 50/5A CT including wiring

15 PVC Pipe 40 mm Dia Mtrs 6 50 300 0 0


PVC Insulated wire 25 Sqmm Single Core Multi
16 Mtrs 25 32 800 0 0
stranded
Anti Climbing Device (12mtrs/1Kg GI Barbed Wire)
17 Kgs 25 64 1600 25 625
Lumpsum

Total 295765 50319

18 Labour charges

a) Casual 50319

b) Regular 10064

Total Cost/Km in Rs. 356148

Note:
1) RCC Poles shall be used for dead ends, DP structure and PSC poles for intermediate supports

2) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 9
Running LT, 3-Phase 4 Wire Power Line on 9.0 Mtr Supports Using RABBIT ACSR Conductor with an
Average Span of 40 Mtrs

Material cost Labour Cost


SL.
Particulars Unit Qty
No
Rate Amt Rate Amt

1 RCC Pole - 9 Mtrs Long, 145 kg WL Nos 1 5941 5941 1060 1060

2 PSC Pole - 9 Mtrs Long, 200 kg WL Nos 24 3401 81624 1060 25440

LT 4 Pin cross arms, with pole clamps, bolts, nuts and


3 Set 1 263 263 96 96
washers (for RCC poles)
LT 4 Pin cross arms, with pole clamps, bolts, nuts and
4 Sets 24 255 6120 96 2304
washers (for PSC poles)

5 1.1kV Pin Insulators with GI Pins Nos 96 38 3648 0 0

6 No.8 Strain Insulators Nos 8 14 112 0 0

7 Guy Set Complete Sets 8 723 5784 354 2832

8 Rabbit ACSR Conductor Kms 4.06 33636 136562 2608 10588

9 Spiral Earth Electrode Nos 25 207 5175 55 1375

10 Concreting materials for guy sets without cement Nos 8 158 1264 0 0

Anti Climbing Device (12mtrs/1Kg GI Barbed Wire)


11 Kgs 25 64 1600 25 625
Lumpsum

Total 248093 44320

12 Labour charges

a) Casual 44320

b) Regular 8864

Total Cost/Km in Rs. 301278

Note: 1) RCC Poles shall be used for dead ends, DP structure and PSC poles for intermediate supports

2) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 8
Running LT , 3-Phase 4 Wire Power Line on 8.0 Mtr Supports Using RABBIT ACSR Conductor with an
Average Span of 40 Mtrs

Material cost Labour Cost


SL.
Particulars Unit Qty
No
Rate Amt Rate Amt

1 RCC Pole - 8 Mtrs Long, 145 kg WL Nos 1 4351 4351 848 848

2 PCC Pole - 8 Mtrs Long, 200 kg WL Nos 24 2495 59880 848 20352

LT 4 Pin cross arms, with pole clamps, bolts, nuts and


3 Set 1 263 263 96 96
washers (for RCC poles)

LT 4 Pin cross arms, with pole clamps, bolts, nuts and


4 Sets 24 255 6120 96 2304
washers (for PCC poles)

5 1.1kV Pin Insulators with GI Pins Nos 96 38 3648 0 0

6 No.8 Strain Insulators Nos 8 14 112 0 0

7 Guy Set Complete Sets 8 723 5784 354 2832

8 Rabbit ACSR Conductor Kms 4.06 33636 136562 2608 10588

9 Spiral Earth Electrode Nos 25 207 5175 55 1375

10 Concreting materials for guy sets without cement Nos 8 158 1264 0 0

Anti Climbing Device (12mtrs/1Kg GI Barbed Wire)


11 Kgs 25 64 1600 25 625
Lumpsum

Total 224759 39020

12 Labour charges

a) Casual 39020

b) Regular 7804

Total Cost/Km in Rs. 271584

Note: 1) RCC Poles shall be used for dead ends, DP structure and PSC poles for intermediate supports

2) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 7
Running LT, 3-Phase 4 Wire Power Line on 8.0 Mtr Supports Using WEASEL ACSR Conductor with an
Average Span of 60 Mtrs (IP Installations)

Material cost Labour Cost


SL.
Particulars Unit Qty
No
Rate Amt Rate Amt

1 RCC Pole - 8 Mtrs Long, 145 kg WL Nos 1 4351 4351 848 848

2 PCC Pole - 8 Mtrs Long, 200 kg WL Nos 17 2495 42415 848 14416

LT 4 Pin cross arms, with pole clamps, bolts, nuts and


3 Set 1 263 263 96 96
washers (for RCC poles)
LT 4 Pin cross arms, with pole clamps, bolts, nuts and
4 Sets 17 255 4335 96 1632
washers (for PCC poles)

5 1.1 kV Pin Insulators with GI Pins Nos 64 38 2432 0 0

6 No.8 Strain Insulators Nos 8 14 112 0 0

7 Guy Set Complete Sets 8 723 5784 354 2832

8 Weasel ACSR Conductor Kms 4.06 20100 81606 1913 7767

9 Spiral Earth Electrode Nos 18 207 3726 55 990

10 Concreting materials for guy sets without cement Nos 8 158 1264 0 0

Anti Climbing Device (12mtrs/1Kg GI Barbed Wire)


11 Kgs 18 64 1152 25 450
Lumpsum

Total 147440 29031

12 Labour charges

a) Casual 29031

b) Regular 5806

Total Cost/Km in Rs. 182277

Note: 1) RCC Poles shall be used for dead ends, DP structure and PSC poles for intermediate supports

2) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 6
Running Single Circuit 11 kV, 3-Phase Power Line & 3 Phase 4 Wire Secondary Line on 9.0 Mtr Supports with an Average Span of
40 Mtrs Using RABBIT ACSR conductor for HT & LT Lines

SL. Material cost Labour Cost


Particulars Unit Qty
No
Rate Amt Rate Amt

1 RCC Pole - 9 Mtrs Long, 145 kg WL Nos 1 5941 5941 1060 1060

2 PSC Pole - 9 Mtrs Long, 200 kg WL No's 23 3401 78223 1060 24380

Horizontal cross arms with clamps, HTST supports,


3 Set 1 382 382 99 99
bolts, nuts and washers (for RCC poles)

Horizontal cross arms with clamps, HTST supports,


4 Sets 23 377 8671 99 2277
bolts, nuts and washers (for PSC poles)

LT 4 Pin cross arms, with pole clamps, bolts, nuts and


5 Set 1 263 263 96 96
washers (for RCC poles)

LT 4 Pin cross arms, with pole clamps, bolts, nuts and


6 Sets 24 258 6192 96 2304
washers(for PSC poles)

7 DP Structure with 9 mtr RCC Poles Set 1 15910 15910 3252 3252

8 11kV Pin Insulators with GI pins Nos 72 94 6768 0 0

9 1.1kV Pin Insulators with GI Pins Nos 96 38 3648 0 0

10 45kN Disc Insulators Nos 6 290 1740 0 0

11 No.8 Strain Insulators Nos 8 14 112 0 0

12 Guy Set Complete Sets 8 742 5936 354 2832

13 Rabbit ACSR Conductor Kms 7.105 33676 239268 2608 18530

14 PG Clamps for Rabbit conductor Nos 6 76 456 0 0

15 Spiral Earth Electrode Nos 26 207 5382 55 1430

16 Guarding between HT & LT Lines

a) Guarding Materials Span 25 2720 68000 603 15075

b) 4 Pin cross arms with clamps,bolts, nuts and


Sets 25 263 6575 0 0
washers.

17 Concreting materials for guy sets without cement Nos 8 158 1264 0 0

Caution/Danger Board as per Drawing No.


18 Nos 8 120 960 48 384
BESCOM/GM/CP/40/Dt: 24.10.07

Anti Climbing Device (12mtrs/1Kg GI Barbed Wire)


19 Kgs 26 64 1664 25 650
Lumpsum

Total 457355 72369

20 Labour charges

a) Casual 72369

b) Regular 14474

Total Cost/Km in Rs. 544198

Note: 1) RCC Poles shall be used for dead ends, DP structure and PSC poles for intermediate supports

2) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 5
Running Single Circuit 11 kV 3 Phase Power Line and 3 Phase - 4 Wire Secondary Line on 9 Mtr Supports with an Average Span of
50 Mtrs using RABBIT Conductor for HT and WEASEL for LT Lines

Sl Material cost Labour Cost


Particulars Unit Qty
No
Rate Amt Rate Amt

1 RCC Pole - 9 Mtrs Long, 145 kg WL Nos 1 5941 5941 1060 1060

2 PSC Pole - 9 Mtrs Long, 200 kg WL Nos 18 3401 61218 1060 19080

11kV Horizontal cross arms with clamps, HTST


3 Set 1 382 382 99 99
Supports, bolts, nuts and washers (for RCC poles)

11kV Horizontal cross arms with clamps, HTST


4 Sets 18 377 6786 99 1782
Supports, bolts, nuts and washers (for PSC poles)

LT 4 Pin cross arms, with pole clamps, bolts, nuts and


5 Set 1 263 263 96 96
washers (for RCC poles)

LT 4 Pin cross arms, with pole clamps, bolts, nuts and


6 Sets 19 258 4902 96 1824
washers (for PSC poles)

7 DP Structure with 9 mtr RCC Poles Set 1 15910 15910 3252 3252

8 11kV Pin Insulators with GI pins Nos 57 94 5358 0 0

9 1.1kV Pin Insulators with GI Pins Nos 76 38 2888 0 0

10 45kN Disc Insulators Nos 6 290 1740 0 0

11 No.8 Strain Insulators Nos 8 14 112 0 0

12 Guy Set Complete Sets 8 742 5936 354 2832

13 Rabbit ACSR for HT Lines Kms 3.045 33676 102543 2608 7941

14 Weasel ACSR for LT lines Kms 4.06 20100 81606 1913 7767

15 Spiral Earth Electrode Nos 21 207 4347 55 1155

16 Guarding between HT & LT Lines

a) Guarding Materials Span 20 2720 54400 603 12060

b) 4 Pin cross arms with clamps,bolts, nuts and


Sets 20 263 5260 0 0
washers.

17 PG Clamps for Rabbit conductor Nos 6 158 948 0 0

18 Concreting Materials for guy sets Nos 8 120 960 0 0

Caution/Danger Board as per Drawing No.


19 Nos 7 120 840 48 336
BESCOM/GM/CP/40/Dt: 24.10.07

Anti Climbing Device (12mtrs/1Kg GI Barbed Wire)


20 Kgs 21 64 1344 25 525
Lumpsum
Total 363684 59809

21 Labour charges

a) casual 59809

b) Regular * 11962
Total Cost/Km in Rs 435455

Note: 1) RCC Poles shall be used for dead ends, DP structure and PSC poles for intermediate supports

2) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 4
Running Single Circuit 11 kV, 3-Phase Power Line on 9.0 Mtr Supports with an Average Span of 40 Mtrs Using COYOTE ACSR
conductor

Material cost Labour Cost


SL.
Particulars Unit Qty
No
Rate Amt Rate Amt

1 RCC Pole - 9 Mtrs Long, 145 kg WL Nos 1 5941 5941 1060 1060

2 PSC Pole - 9 Mtrs Long, 200 kg WL Nos 22 3401 74822 1060 23320

Horizontal cross arms with clamps, HTST supports,


3 Set 1 382 382 99 99
bolts, nuts and washers (for RCC poles)
Horizontal cross arms with clamps, HTST supports,
4 Sets 22 377 8294 99 2178
bolts, nuts and washers (for PSC poles)

5 DP Structure with 9 Mtrs RCC Poles Sets 2 15910 31820 3252 6504

6 11kV Pin Insulators with GI pins Nos 69 94 6486 0 0

7 70/90 kN Disc Insulators Nos 12 490 5880 0 0

8 Strain Clamp 3 bolt type for Disc Insulator Nos 12 468 5616 0 0

9 Guy Set Complete Sets 6 742 4452 354 2124

10 Coyote ACSR Conductor Kms 3.045 92708 282296 4555 13870

11 PG Clamps for Coyote Conductor Nos 12 267 3204 0 0

12 Spiral Earth Electrode Nos 27 207 5589 55 1485

Set of 2
13 EG Stirrups with GI wire lacing 23 370 8510 99 2277
Nos

14 Concreting materials for guy sets without cement Nos 6 158 948 0 0

Caution/Danger Board as per Drawing No.


15 Nos 10 120 1200 48 480
BESCOM/GM/CP/40/Dt: 24.10.07

Anti Climbing Device (12mtrs/1Kg GI Barbed Wire)


16 Kgs 27 64 1728 25 675
Lumpsum

Total 447168 54072

17 Labour charges

a) Casual 54072

b) Regular 10814

Total Cost/Km in Rs. 512054

Note: 1) RCC Poles shall be used for dead ends, DP structure and PSC poles for intermediate supports

2) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 3
Running Single Circuit 11 kV , 3-Phase Power Line on 8.0 Mtr Supports with an Average Span of 50 Mtrs Using RABBIT ACSR
Conductor

Material cost Labour Cost


SL.
Particulars Unit Qty
No
Rate Amt Rate Amt

1 RCC Pole - 8.0M Long, 145 kg WL Nos 1 4351 4351 848 848

2 PCC Pole - 8.0M Long, 200 kg WL Nos 18 2495 44910 848 15264

Horizontal cross arms with clamps, HTST supports,


3 Set 1 382 382 99 99
bolts, nuts and washers (for RCC poles)
Horizontal cross arms with clamps, HTST supports,
4 Sets 18 377 6786 99 1782
bolts, nuts and washers (for PCC poles)

5 DP Structure with 8 Mtrs RCC Poles Set 1 12730 12730 3104 3104

6 11kV Pin Insulators with GI pins Nos 57 94 5358 0 0

7 45kN Disc Insulators Nos 6 290 1740 0 0

8 Guy Set Complete Sets 6 742 4452 354 2124

9 Rabbit ACSR Conductor Kms 3.045 33676 102543 2608 7941

10 PG Clamps for Rabbit Conductor Nos 6 76 456 0 0

11 Spiral Earth Electrode Nos 21 207 4347 55 1155

Set of 2
12 EG Stirrups with GI wire lacing 19 370 7030 99 1881
Nos

13 Concreting materials for guy sets without cement Nos 6 158 948 0 0

Caution/Danger Board as per Drawing No.


14 Nos 8 120 960 48 384
BESCOM/GM/CP/40/Dt: 24.10.07

Anti Climbing Device (12mtrs/1Kg GI Barbed Wire)


15 Kgs 21 64 1344 25 525
Lumpsum

Total 198337 35107

16 Labour charges

a) Casual 35107

b) Regular 7021

Total Cost/Km in Rs. 240466

Note: 1) RCC Poles shall be used for dead ends, DP structure and PSC poles for intermediate supports

2) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 2
Running Single Circuit 11 kV, 3-Phase Power Line on 9.0 Mtr Supports with an Average Span of 50 Mtrs Using Rabbit ACSR
Conductor

Material cost Labour Cost


SL.
Particulars Unit Qty
No
Rate Amt Rate Amt

1 RCC Pole - 9 Mtrs Long, 145 kg WL Nos 1 5941 5941 1060 1060

2 PSC Pole - 9 Mtrs Long, 200 kg WL Nos 18 3401 61218 1060 19080

Horizontal cross arms with clamps, HTST supports,


3 Set 1 382 382 99 99
bolts, nuts and washers (for RCC poles)
Horizontal cross arms with clamps, HTST supports,
4 Set 18 377 6786 99 1782
bolts, nuts and washers (for PSC poles)

5 DP Structure with 9 Mtrs RCC Poles Set 1 15910 15910 3252 3252

6 11kV Pin Insulators with GI pins Nos 57 94 5358 0 0

7 45kN Disc Insulators Nos 6 290 1740 0 0

8 Guy Set Complete Sets 6 742 4452 354 2124

9 Rabbit ACSR Conductor Kms 3.045 33676 102543 2608 7941

10 PG Clamps for Rabbit conductor Nos 6 76 456 0 0

11 Spiral Earth Electrode Nos 21 207 4347 55 1155

Set of
12 EG Stirrups with GI wire lacing 19 370 7030 99 1881
2 Nos

13 Concreting materials for guy sets without cement Nos 6 158 948 0 0

Caution/Danger Board as per Drawing No.


14 Nos 8 120 960 48 384
BESCOM/GM/CP/40/Dt: 24.10.07

Anti Climbing Device (12mtrs/1Kg GI Barbed Wire)


15 Kg 21 64 1344 25 525
Lumpsum

Total 219415 39283

16 Labour charges

a) Casual 39283

b) Regular 7857

Total Cost/Km in Rs. 266555

Note: 1) RCC Poles shall be used for dead ends, DP structure and PSC poles for intermediate supports

2) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 1
Running Single Circuit 11kV, 3 Phase Power Line On 9.0 Mtr Supports With An Average Span Of 40 Mtrs Using Rabbit ACSR
Conductor

Material cost Labour Cost


SL.
Particulars Unit Qty
No
Rate Amt Rate Amt

1 RCC Pole - 9 Mtrs Long, 145 kg WL Nos 1 5941 5941 1060 1060

2 PSC Pole - 9 Mtrs Long, 200 kg WL Nos 23 3401 78223 1060 24380

Horizontal cross arms with clamps, HTST supports,


3 Set 1 382 382 99 99
bolts, nuts and washers for RCC poles
Horizontal cross arms with clamps, HTST supports,
4 Set 23 377 8671 99 2277
bolts, nuts and washers for PSC poles

5 DP Structure with 9 Mtrs RCC Poles Set 1 15910 15910 3252 3252

6 11 kV Pin Insulators with GI pins Nos 72 94 6768 0 0

7 45 kN Disc Insulators Nos 6 290 1740 0 0

8 Guy Set Complete Sets 6 742 4452 354 2124

9 Rabbit ACSR Conductor Kms 3.045 33676 102543 2608 7941

10 PG Clamps for Rabbit Conductor Nos 6 76 456 0 0

11 Spiral Earth Electrode Nos 26 207 5382 55 1430

Set of 2
12 EG Stirrups with GI wire lacing 24 370 8880 99 2376
Nos

13 Concreting materials for guy sets without cement Nos 6 158 948 0 0

Caution/Danger Board as per Drawing No.


14 Nos 8 120 960 48 384
BESCOM/GM/CP/40/Dt: 24.10.07

Anti Climbing Device (10mtrs/1 Kg GI Barbed Wire)


15 Nos 26 64 1664 25 650
Lumpsum

Total 242920 45973

16 Labour charges

a) Casual 45973

b) Regular 9195

Total Cost/Km in Rs. 298088

Note: 1) RCC Poles shall be used for dead ends, DP structure and PSC poles for intermediate supports

2) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 49
Standard Requirement of Materials for providing LT Wiring for Distribution
Transformer Centers of various capacities
LT Wiring for - 250/500 KVA
Rate/Unit
Sl No Material Unit
(in Rs)
1 Al Lead Wire - 240 Sqmm Mtrs 200
2 Copper lugs - 240 Sqmm Nos 184
3 PG Clamps - Rabbit to 240 Sqmm Nos 307
4 Spacers for DTC Wiring Nos 38
4 Pin Cross Arm with necessary Clamps,bolts & nuts etc
5 Nos 352
complete (Galvanised )
Fish Plate with necessary Clamps,bolts & nuts etc
6 Nos 155
complete (Galvanised )

LT Wiring for - 100 KVA


Rate/Unit
Sl No Material Unit
(in Rs)
1 Al Lead Wire - 120 Sqmm Mtrs 108
2 Copper lugs - 120 Sqmm Nos 77
3 PG Clamps - Rabbit to 120 Sqmm Nos 204
4 Spacers for DTC Wiring Nos 38
4 Pin Cross Arm with necessary Clamps,bolts & nuts etc
5 Nos 352
complete (Galvanised )
Fish Plate with necessary Clamps,bolts & nuts etc
6 Nos 155
complete (Galvanised )

LT Wiring for - 63 KVA


Rate/Unit
Sl No Material Unit
(in Rs)
1 Al Lead Wire - 95 Sqmm Mtrs 82
2 Copper lugs - 95 Sqmm Nos 71
3 PG Clamps - Rabbit to 95 Sqmm Nos 105
4 Spacers for DTC Wiring Nos 38
4 Pin Cross Arm with necessary Clamps,bolts & nuts etc
5 Nos 352
complete (Galvanised )
Fish Plate with necessary Clamps,bolts & nuts etc
Nos 155
complete (Galvanised )

LT Wiring for - 25 KVA


Rate/Unit
Sl No Material Unit
(in Rs)
1 Al Lead Wire - 50 Sqmm Mtrs 45
2 Copper lugs - 50 Sqmm Nos 30
3 PG Clamps - Rabbit to 50 Sqmm Nos 66
4 Spacers for DTC Wiring Nos 38
4 Pin Cross Arm with necessary Clamps,bolts & nuts etc
5 Nos 352
complete (Galvanised )
Fish Plate with necessary Clamps,bolts & nuts etc
6 Nos 155
complete (Galvanised )

The size of the lead wire provisioned are as per Standard requirement depending on the
Ampere rating of the transformer.
The Size of the cable mabe modified to suite field requirement where ever necessary.
COST DATA SHEET - 48

Consolidated Labour charges for shifting of conductor and all other


fittings existing on the deteriorated pole while replaceing intermediate
poles(Does not include labour chages for releasing and erection of pole)

Labour
Sl. No. Description of the work Unit charges of the
work

Consolidated Labour charges for


shifting of the existing conductor,
including all works associated with
shifting of the conductor such as any
1 Per Pole Rs.2200/-
fittings, aerial fuse boards, cut outs,
service main (UG cable and over head)
etc., on the existing deteriorated
intermediate pole to new pole erected.
COST DATA SHEET - 47

Consolidated Labour charges for shifting of conductor terminations and all other
fittings existing on the deteriorated pole while replaceing termination(cut point)
poles(Does not include labour chages for releasing and erection of pole)

Labour charges of
Sl. No. Description of the work Unit
the work

Consolidated Labour charges for shifting


of the conductor terminations(existing cut
points) in deteriorated existing poles to
new poles erected. Work includes all
1 works associated with shifting of the Per Pole Rs.3000/-
terminations, like shifting of aerial fuse
boards, cut outs, service main(UG cable
and over head) and any other existing
fitting.
COST DATA SHEET - 46
Estimate for carrying out 1 to 4 (ONE to FOUR) poles works in respect of Service Main
Connection and E&I Works only

(Not applicaple for any other type of work)


No. of
SL. Pole Consolidated
Paritculars Unit
No Works Amount in Rs.
Involved

PART-A (Materials)

Material cost Estimate shall be prepared as per


1
site requirement
PART-B (Labour)

Consolidated labour charges for works 1 to 4 Nos 1 4238


(ONE to FOUR) poles including excavation of pit, Nos 2 5650
pole erection, fixing of cross arms, stringing of Nos 3 7063
2 conductor, fixing of conductor accessories, fixing Nos 4 8475
guy sets, fixing of anti climbing device, spiral
earth electrode, danger board etc if any 5& as per Common
(Applicable for both HT & LT Line) Above SR 2016-17
Note:-

The labour charges includes all works such as digging of pits, Erection of Poles, Fixing of
1 Cross Arms, Strining of conductor, fixing of Conductore accessories, insulators, Fixing
guy sets, Anti climbing device, spiral earth electrode and danger board etc complete

No other labour charges or any other charges towards special locality allowance LC
2 Charges, additional labour charges, transportation charges etc., are payable.

3 Estimate shall not split to bring them into this category

Certificate has to be furnished by the section officer who prepares the estimate that the
4 estimates are not split to claim the above labour charges

5 The above rates are not applicable for works awarded on tender
COST DATA SHEET - 45
Estimate for Carrying Out 3 to 5 (THREE to FIVE) Poles Works in respect of Ganga
Kalyana and Drinking Water Supply Works only

(Not applicaple for any other type of work)


SL. Consolidated
Paritculars Unit Qty
No Amount in Rs.
PART-A (Materials)
Material cost Estimate shall be prepared
1
as per site requirement
PART-B (Labour)
Consolidated labour charges involving 3
to 5 (THREE to FIVE) pole works for
2 Nos 1 13949
Ganga Kalyana and Drinking Water
supply works only.

Note:-
The labour charges includes all works such as digging of pits, Errection of
1
Poles, Fixing of Cross Arms, insulators, Strining of wire, providing guy sets.

No other labour charges or any other charges towards special locality


2 allowance LC Charges, additional labour charges, transportation charges etc.,
are payable.
Estimates coverig more than 3 pole works shall not split to bring them into
3
this catageory.

Certificate has to be furnished by the section officer who prepares the


4
estimate that the estimates are not split to claim the above labour charges
5 The above rates are not applicable for works awarded on tender
COST DATA SHEET - 44
Estimate for Carrying Out 1 to 2 (One to Two) Poles Works in respect of Ganga
Kalyana and Drinking Water Supply Works only

(Not applicaple for any other type of work)


SL. Consolidated
Paritculars Unit Qty
No Amount in Rs.
PART-A (Materials)

Material cost Estimate shall be prepared


1
as per site requirement

PART-B (Labour)
Consolidated labour charges involving 1
to 2 (ONE to TWO) pole works for Ganga
2 Nos 1 8829
Kalyana and Drinking Water supply
works only.

Note:-

The labour charges includes all works such as digging of pits, Erection of
1 Poles, Fixing of Cross Arms, insulators, Strining of wire, providing guy sets.

No other labour charges or any other charges towards special locality


2 allowance LC Charges, additional labour charges, transportation charges etc.,
are payable.

Estimates coverig more than 2 pole works shall not split to bring them into
3 this catageory.

Certificate has to be furnished by the section officer who prepares the


4 estimate that the estimates are not split to claim the above labour charges
5 The above rates are not applicable for works awarded on tender
COST DATA SHEET - 43
For providing LT Capacitor to the Distribution Transformer

Sl. Material cost Labour Cost


Materials Unit Qty
No
Rate Amt Rate Amt

Fixing 3 kVAr, 3 Phase, LT Capacitor housed in a


enclosure with necessary Fuses, wiring,
1 mounting arrangement for 15/25kVA DTC Set 1 525 525 382 382
(including connection to transformer, grounding
etc., complete)
Fixing 9 kVAr, 3 Phase, LT Capacitor housed in a
enclosure with necessary Fuses, wiring,
2 mounting arrangement for 63kVA DTC (including Set 1 931 931 382 382
connection to transformer, grounding etc.,
complete)
Fixing 18 kVAr, 3 Phase, LT Capacitor housed in
a enclosure with necessary Fuses, wiring,
3 mounting arrangement for 100kVA DTC Set 1 1733 1733 450 450
(including connection to transformer, grounding
etc., complete)

Fixing 27 kVAr, 3 Phase, LT Capacitor housed in


a enclosure with necessary Fuses, wiring,
4 mounting arrangement for 250kVA DTC Set 1 2758 2758 525 525
(including connection to transformer, grounding
etc., complete)
Fixing 54 kVAr, 3 Phase, LT Capacitor housed in
a enclosure with necessary Fuses, wiring,
5 mounting arrangement for 300/500 kVA DTC Set 1 4883 4883 549 549
(including connection to transformer, grounding
etc., complete)

Wiring Materials for connecting the Capacitors to


the Transformer (16 Sqmm Single Core PVC
insulated sheathed aluminium wire, aluminium
6 Set 1 200 200 0 0
lugs, 2mm thick 40mm dia PVC pipe with Bend)
and connecting the capacitor box to existing
grounding

Material +
Total Material Labour
Labour
a) For 25KVA Transformer 1107 725 382

b) For 63KVA Transformer 1513 1131 382

c) For 100KVA Transformer 2383 1933 450

d) For 250KVA Transformer 3483 2958 525

e) For 300/500 KVA Transformer 5632 5083 549

While preparing estimates for turnkey / total turnkey projects please refere to Sl. No. …….. To general guidelines
1
vide a to …. page No. ……. To ……..
COST DATA SHEET - 42
For Providing Electronic Trivector Meters with Associated CT's Metering Box etc., on LT Side of
Distribution Transformer Center

Sl. Material cost Labour Cost


Materials Unit Qty
No
Rate Amt Rate Amt
LT CT's Class - 1 Accuracy Ring Type Ratio
1 Nos 3 554 1662 63 189
50/5 for 15/25kVA DTC
LT CT's Class - 0.5 Accuracy Ring Type Ratio
2 Nos 3 408 1224 63 189
100/5 for 50/63kVA DTC
LT CT's Class - 0.5 Accuracy Ring Type Ratio
3 Nos 3 306 918 63 189
150/5 for 100kVA DTC
LT CT's Class - 0.5 Accuracy Ring Type Ratio
4 Nos 3 360 1080 63 189
400/5 for 250kVA DTC

LT CT's Class - 0.5 Accuracy Ring Type Ratio


5 Nos 3 405 1215 63 189
800/5 for 500 kVA DTC

Electronic Trivector Meter 3 Phase, 4 Wire,


6 No 1 2250 2250 631 631
Accuracy 0.5 Cl

Weather Proof, Verming Proof LT Metering Box


with clamping arrangement for mounting on the
Transformer structure with necessary terminal
7 No 1 4000 4000 325 325
strip and CT mounting arrangement for housing
the ETV Meters and connecting to the existing
ground.

Total Cost in Rs. With Meter Without Meter

a) 15/25kVA DTC 7912 1145 5662 514

b) 63kVA DTC 7474 1145 5224 514

c) 100kVA DTC 7168 1145 4918 514

d) 250kVA DTC 7330 1145 5080 514

e) 500kVA DTC 7465 1145 5215 514

While preparing estimates for turnkey/total turnkey projects please refere to Sl. No. …….. To general
1
guidelines vide a to …. page No. ……. To ……..
COST DATA SHEET - 41
Providing Compact Pre-fabricated Packaged Sub-station 11kV/433V

Sl
Particulars Unit Total Cost
No
Packaged Sub-station 11kV/433V consisting of 3 Way SF6/VCB insulated Compact RMU,
1
Oil cooled type Copper Wound Transformer and LT section with one ACB as incoming and 7
(i) With 100kVA oil cooled Transformer Set

(ii) With 250kVA oil cooled Transformer Set

(iii) With 500kVA oil cooled Transformer Set

(iv) With 750kVA oil cooled Transformer Set


Will be
(v) With 990kVA oil cooled Transformer Set
Furnished
after the
(vi) With 100kVA Dry Type Transformer Set
report of
the
(vii) With 250kVA Dry Type Transformer Set
committee
(viii) With 500kVA Dry Type Transformer Set

(ix) With 750kVA Dry Type Transformer Set

(x) With 990kVA Dry Type Transformer Set


Installing & fixing the compact pre-fabricated packaged sub-station 100/250/500/750/
2
990 kVA transformer on the existing concrete plinth.(This does not include the cost of
Note :
While preparing estimates for turnkey/total turnkey projects please refere to Sl. No. …….. To general guidelines vide
1
a to …. page No. ……. To ……..
2 Revised Cost Data Sheet will be furnished after the rates for CSS, RMU etc. are finalised by the committee.
COST DATA SHEET - 40

Installing RLMU for the Existing 100kVA Distribution Transformer Center

Material cost

Sl No Particulars Unit Qty

Rate Amt

1 Metallic Enclosure with Busbars No 1 10752 10752

Programmable Logic Controllers with communication


2 No 1 19339 19339
ports

3 GSM Modem No 1 7642 7642

4 MCCB - 150 Amps for 100 kVA DTC No 1 1700 1700

5 MCB 6 amps No 1 210 210

6 Contactors - 160 Amps for 100 kVA DTC No 2 5775 11550

7 Current Transformers 150/5 amps for 100 kVA DTC No 3 306 918

Electronic Trivector Meter 3 Phase, 4 Wire, Accuracy


8 No 1 2250 2250
0.5 Cl

Transformer wiring kit to Connect RLM Unit box to the


9 transformer using PVC sheathed aluminium lead wire, Kit 1 7322 7322
Lugs etc.,

10 Miscellaneous materials LS LS 62 62

Total Cost (Material) 61745

11 Labour Charges

a) Casual 3483

b) Regular 697

12 Total Cost 65925

While preparing estimates for turnkey / total tunkey projects please refer to Sl. No. ......... of General
1)
Guidelines vide a to .... in Page No. ...........
COST DATA SHEET - 39
Installing RLMU for the Existing 63 kVA Distribution Transformer Center

Material cost
Sl No Particulars Unit Qty
Rate Amt

1 Metallic Enclosure with Busbars No 1 10752 10752

Programmable Logic Controllers with communication


2 No 1 19339 19339
ports

3 GSM Modem No 1 7642 7642

4 MCCB - 100 Amps for 63 kVA DTC No 1 1500 1500

5 MCB 6 amps No 1 210 210

6 Contactors - 100 Amps for 63 kVA DTC No 2 3280 6560

7 Current Transformers 100/5 amps for 63 kVA DTC No 3 408 1224

Electronic Trivector Meter 3 Phase, 4 Wire, Accuracy


8 No 1 2250 2250
0.5 Cl
Transformer wiring kit to Connect RLM Unit box to the
9 transformer using PVC sheathed aluminium lead wire, Kit 1 4612 4612
Lugs etc.,

10 Miscellaneous materials LS LS 23 23

Total Cost (Material) 54112

11 Labour Charges

a) Casual 3483

b) Regular 697

Total Cost 58292

While preparing estimates for turnkey/total tunkey projects please refer to Sl. No. ......... of General
1)
Guidelines vide a to .... in Page No. ...........
COST DATA SHEET - 38
Installing RLMU for the Existing 15/25kVA Distribution Transformer Center

Material cost
Sl No Particulars Unit Qty
Rate Amt

1 Metallic Enclosure with Busbars No 1 10752 10752

Programmable Logic Controllers with communication


2 No 1 19339 19339
ports

3 GSM Modem No 1 7642 7642

4 MCCB - 40 Amps for 15/25 kVA DTC No 1 1485 1485

5 MCB 6 amps No 1 210 210

6 Contactors - 40 Amps for 15/25 kVA DTC No 2 2010 4020

7 Current Transformers 50/5 amps for 15/25 kVA DTC No 3 554 1662

Electronic Trivector Meter 3 Phase, 4 Wire, Accuracy


8 No 1 2250 2250
0.5 Cl
Transformer wiring kit to Connect RLM Unit box to the
9 transformer using PVC sheathed aluminium lead wire, Kit 1 2060 2060
Lugs etc.,

10 Miscellaneous materials LS LS 147 147

Total Cost of Material 49567

11 Labour Charges

a) Casual 3483

b) Regular 697

Total Cost 53747


Note: (1) For 15 /25 kVA Transformer feeding to individual IP sets, use only one contactor & without MCCB
.

While preparing estimates for turnkey / total tunkey projects please refer to Sl. No. ......... of General
1)
Guidelines vide a to .... in Page No. ...........
COST DATA SHEET - 37
Running Single Circuit 1.1 kV 3 Phase 5 Wire Power Line on 9 Mtr Supports with Average Span of 40 Mtrs Using
3x95 + 1x16 + 1x70 Sqmm Aerial Bunched Cables (ABC)

SL. Material cost Labour Cost


Particulars Unit Qty
No
Rate Amt Rate Amt

1 RCC Poles 9 Mtr long with 145 Kg WL Nos 10 5941 59410 1060 10600

2 PSC Poles 9 Mtr long with 200 Kg WL Nos 15 3401 51015 1060 15900

Note: RCC Poles shall be used for dead ends, DP structure and PSC poles for intermediate supports and hence
the quantity of RCC and PSC poles may be revised as per field condition.
1.1kV Class 3 Phase Aerial Bunched Cable of
3 kms 1.015 410000 416150 20426 20732
size 3x95+1x16+1x70 Sqmm

4 Three Phase Distribution box for 6 Connections Nos 20 2065 41300 538 10760

Piercing connector suitable for 16 Sqmm - 95


5 Nos 60 228 13680 77 4620
Sqmm AB Cable - Service Connections

Piercing connector suitable for 16 Sqmm - 95


6 Nos 25 160 4000 54 1350
Sqmm AB Cable - Street Light Connections
Suspension Clamp Assembly 16 to 70 mm
7 Sets 20 190 3800 115 2300
( Excluding pole clamp & Eye Hook )

8 Pole clamp for HT/LT AB cable Sets 20 100 2000 192 3840

Eye Hook (Flat type) for fixing Clamps Sets 20 90 1800 0 0


Dead End Clamp/Anchor Clamp Assembly 25
8 to 95 Sq mm (excluding pole clamps and Eye Sets 16 200 3200 115 1840
hook)
9 Universal Hook, Bolts & nuts Nos 16 305 4880 115 1840

10 T-connector KZ3 95 Nos 8 338 2704 130 1040


Cable Straight thru' joint kits suitable for 95
11 Sets 5 310 1550 192 960
Sqmm

12 Pre-Insulated lugs-CPTAU for 95 Sqmm Nos 8 338 2704 160 1280

13 End cap for 50/70 Sqmm Nos 50 19 950 5 250

14 Guy Set Complete Sets 8 723 5784 354 2832

15 Concreting for Guy sets (without cement) Sets 8 158 1264 0 0

16 PVC Insulated wire 16/25 Sqmm Mtrs 400 23.52 9408 0 0

17 Spiral Earth Electrodes Nos 25 207 5175 55 1375

Total Cost of Materials 630774

18 Labour Charges

a) Casual 81519

b) Regular 16304

Total Cost/Km in Rs. 728597

While preparing estimates for turnkey / total turnkey projects please refere to Sl. No. …….. To general
1
guidelines vide a to …. page No. ……. To ……..
COST DATA SHEET - 36
Running Single Circuit 11kV, 3 Phase Power Line on 9 Mtr Supports with an Average Span of 30 Mtrs Using 3x95
Sqmm + 1x70 Sqmm Aerial Bunched Cables (ABC)

Material cost Labour Cost


SL.
Particulars Unit Qty
No
Rate Amt Rate Amt

1 RCC Poles 9 Mtr long with 145 Kg WL Nos 10 5941 59410 1060 10600

2 PSC Poles 9 Mtr long with 200 Kg WL Nos 24 3401 81624 1060 25440

Note: RCC Poles shall be used for dead ends, DP structure and PSC poles for intermediate supports and hence
the quantity of RCC and PSC poles may be revised as per field condition.
11kV Class 3 phase Aerial Bunched Cable 3x95
3 Kms 1.015 631000 640465 20426 20732
+ 70 Sqmm

Cable Straight thru' joint kits suitable for 95


4 Nos 6 5650 33900 828 4968
Sqmm
11 KV AB CableTermination Kits fo 95 to 120
6 Nos 6 2100 12600 700 4200
Sqmm
Suspension Clamp Assembly 16 to 70 mm
7 Sets 30 190 5700 115 3450
( Excluding pole clamp & Eye Hook )

Pole clamp for HT/LT AB cable Sets 30 100 3000 192 5760

8 Eye Hook (Flat type) for fixing Clamps Sets 30 90 2700 0 0

Dead End Clamp/Anchor Clamp Assembly 25


to 95 Sq mm (excluding pole clamps and Eye Sets 12 200 2400 115 1380
hook)

9 End Caps Nos 10 19 190 5 50

11kV Lightning Arrester, Metal Oxide


10 Set (3Nos) 2 2409 4818 107 214
9kV, 5kA

11 Guy Set Complete Sets 6 742 4452 354 2124

12 Concreting for Guy sets (without cement) Sets 6 158 948 0 0

13 Grounding connection for messenger wire Nos 4 122 488 26 104

15 Spiral Earth Electrodes Nos 34 207 7038 55 1870

Total Cost of Material 859733

16 Labour Charges

a) Casual 80892.4

b) Regular 16178.5

17 Total Cost/Km in Rs. 956803.9

While preparing estimates for turnkey / total turnkey projects please refere to Sl. No. …….. To general
guidelines vide a to …. page No. ……. To ……..
COST DATA SHEET-35
Providing Compact RMU 11kV Class SF6/VCB Type (1VL)

Schenider Make ABB Make Siemens Make MEI


Sl.
Materials Unit Rate
No
Qty Amt Qty Amt Qty Amt Qty Amt

Will be Will be Will be Will be Will be


1 RMU 1 VL, 350 MVA, 630Amps No 1 1 1 1
intimated intimated intimated intimated intimated

2 Bed Conceting with CC 1:2:4 as per Labour Charges Cmt 5084 0.07 355.88 0.09 457.56 0.1 508.4 0.16 813.44

Foundation with Reinforcement CC 1:2:4 as per


3 Cmt 5084 0.29 1474.36 0.36 1830.24 0.14 711.76 0 0
Labour Charges

Providing Reinforcement as per Labour Charges Item


4 Kgs 60.1 10 600.8 3.5 210.28 6 360.48 0 0
No. 28.1

Providing Plinth with CC 1:2:4 on the Stone


5 Cmt 5084 0 0 0 0 0 0 0.02 101.68
Masonary

6 Construction of Stone Masonary Cmt 3829 0 0 0 0 0 0 0.14 536.06

Supplying of Frame of MS Channel 100x50mm and


7 Kgs 50 12 600 12 600 12 600 12 600
MS angle 40x40x5mm welding etc., complete.

Rod type earthing with 40 mm Dia, 3 Mtrs long MS


8 No 2000 2 4000 2 4000 2 4000 2 4000
rod as per specification & drawing (enclosed)

Lettering the RMU with enamel paint and also


writing single line diagram of each panel, caution
9 No 596 1 596 1 596 1 596 1 596
Board, Danger Board etc., including cost of Paint,
Brush etc.,

Total cost of material.(Excluding Item No.1) 7627.04 7694.08 6776.64 6647.18

Labour Charges

Earth Excavation for R.M.U. Foundation depositing


1 of earth on bank up to a lead of 50 mtrs and with a cmt 178 0.57 101.46 0.83 147.74 0.63 112.14 1.37 243.86
lift up to 1.5 mtrs

Labour charges for Fixing foundation frame of MS


channel 100X50mm and MS angle 40X40X5mm
2 welding, fixing in concrete, aligning the RMU on No. 2836 1 2836 1 2836 1 2836 1 2836
foundation bed, assembly of units, connecting Bus
Bars from panel to panel etc., complete.

Labour Charges 2937.46 2983.74 2948.14 3079.86

a) Casual 2937 2984 2948 3080

b) Regular 587 597 590 616

Total cost of material.(Excluding RMU) 11152 11275 10314 10343

Note:-

The measurements for Earth work and concreting works have been provision as per the dimensions of the equipments of makes which are in use at
1
present in BESCOM. Detail for the measurement are furnished in the data sheet furnished in Page No. ………..

2 While preparing estimates for turnkey / total turnkey projects please refere to Sl. No. …….. To general guidelines vide a to …. page No. ……. To ……..

3 Revised Cost Data Sheet will be furnished after the rates for CSS, RMU etc. are finalised by the committee.
COST DATA SHEET-34
Providing Compact RMU 11kV Class SF6/VCB Type (1OD)

Schenider Make ABB Make Siemens Make MEI


Sl.
Materials Unit Rate
No
Qty Amt Qty Amt Qty Amt Qty Amt

Will be Will be Will be Will be Will be


1 RMU 1 OD , 350 MVA, 630Amps No intimate 1 intimat 1 intimate 1 intimate 1 intimate
d ed d d d

2 Bed Conceting with CC 1:2:4 as per Labour Charges Cmt 5084 0.07 355.88 0.09 457.56 0.1 508.4 0.16 813.44

Foundation with Reinforcement CC 1:2:4 as per Labour


3 Cmt 5084 0.29 1474.36 0.36 1830.24 0.14 711.76 0 0
Charges

Providing Reinforcement as per Labour Charges Item


4 Kgs 60.1 10 600.8 3.5 210.28 6 360.48 0 0
No. 28.1

5 Providing Plinth with CC 1:2:4 on the Stone Masonary Cmt 5084 0 0 0 0 0 0 0.02 101.68

6 Construction of Stone Masonary Cmt 3829 0 0 0 0 0 0 0.14 536.06

Supplying of Frame of MS Channel 100x50mm and MS


7 Kgs 50 12 600 12 600 12 600 12 600
angle 40x40x5mm welding etc., complete.

Rod type earthing with 40 mm Dia, 3 Mtrs long MS rod


8 No 2000 2 4000 2 4000 2 4000 2 4000
as per specification & drawing (enclosed)

Lettering the RMU with enamel paint and also writing


9 single line diagram of each panel, caution Board, No 596 1 596 1 596 1 596 1 596
Danger Board etc., including cost of Paint, Brush etc.,

Total cost of material.(Excluding Item No.1) 7627 7694.08 6776.64 6647.18

Labour Charges

Earth Excavation for R.M.U. Foundation depositing of


1 earth on bank up to a lead of 50 mtrs and with a lift up cmt 178 0.57 101.46 0.83 147.74 0.63 112.14 1.37 243.86
to 1.5 mtrs
Labour charges for Fixing foundation frame of MS
channel 100X50mm and MS angle 40X40X5mm
2 No. 2836 1 2836 1 2836 1 2836 1 2836
welding, fixing in concrete, aligning the RMU on
foundation bed, assembly of units, connecting Bus

Labour Charges 2937.5 2983.74 2948.14 3079.86

a) Casual 2937 2984 2948 3080

b) Regular 587 597 590 616

Total cost of material.(Excluding RMU) 11152 11275 10314 10343

Note:-

The measurements for Earth work and concreting works have been provision as per the dimensions of the equipments of makes which are in use at
1
present in BESCOM. Detail for the measurement are furnished in the data sheet furnished in Page No. ………..

2 While preparing estimates for turnkey / total turnkey projects please refere to Sl. No. …….. To general guidelines vide a to …. page No. ……. To ……..

3 Revised Cost Data Sheet will be furnished after the rates for CSS, RMU etc. are finalised by the committee.
COST DATA SHEET-33
Providing Compact RMU 11kV Class SF6/VCB Type (1 Incomer +1 Breaker +1 Outgoing)

Schenider Make ABB Make Siemens Make MEI


Sl.
Materials Unit Rate
No
Qty Amt Qty Amt Qty Amt Qty Amt

Will be Will be Will be Will be


RMU (3 Way), One Incomer + Two Breakers + One Will be
1 No intimate 1 intimat 1 intimate 1 intimate 1
outgoing (2OD + 1VL), 350 MVA, 630Amps intimated
d ed d d

Bed Conceting with CC 1:2:4 as per Labour


2 Cmt 5084 0.08 406.72 0.28 1423.52 0.43 2186.12 0.48 2440.32
Charges

Foundation with Reinforcement CC 1:2:4 as per


3 Cmt 5084 0.36 1830.24 1.08 5490.72 0.42 2135.28 0 0
Labour Charges

Providing Reinforcement as per Labour Charges


4 Kgs 60.1 30 1802.4 10 600.8 17 1021.36 0 0
Item No. 28.1

Providing Plinth with CC 1:2:4 on the Stone


5 Cmt 5084 0 0 0 0 0 0 0.06 305.04
Masonary

6 Construction of Stone Masonary Cmt 3829 0 0 0 0 0 0 0.43 1646.47

Supplying of Frame of MS Channel 100x50mm


7 Kgs 50 40 2000 40 2000 40 2000 40 2000
and MS angle 40x40x5mm welding etc., complete.

Rod type earthing with 40 mm Dia, 3 Mtrs long


8 No 2000 2 4000 2 4000 2 4000 2 4000
MS rod as per specification & drawing (enclosed)
Lettering the RMU with enamel paint and also
9 writing single line diagram of each panel, caution No 596 1 596 1 596 1 596 1 596
Board, Danger Board etc., including cost of Paint,

Total cost of material.(Excluding Item No.1) 10635 14111 11938.8 10987.83

Labour Charges

Earth Excavation for R.M.U. Foundation


1 depositing of earth on bank up to a lead of 50 mtrs cmt 178 0.72 128.16 2.5 445 2 356 4.35 774.3
and with a lift up to 1.5 mtrs
Labour charges for Fixing foundation frame of MS
2 channel 100X50mm and MS angle 40X40X5mm No. 2836 3 8508 3 8508 3 8508 3 8508
welding, fixing in concrete, aligning the RMU on

Labour Charges 8636.2 8953 8864 9282.3

a) Casual 8636 8953 8864 9282

b) Regular 1727 1791 1773 1856

Total cost of material.(Excluding RMU) 20999 24855 22576 22127

Note:-

The measurements for Earth work and concreting works have been provision as per the dimensions of the equipments of makes which are in
1
use at present in BESCOM. Detail for the measurement are furnished in the data sheet furnished in Page No. ………..

While preparing estimates for turnkey / total turnkey projects please refere to Sl. No. …….. To general guidelines vide a to …. page No. …….
2
To ……..

3 Revised Cost Data Sheet will be furnished after the rates for CSS, RMU etc. are finalised by the committee.
COST DATA SHEET-32
Providing Compact RMU 11kV Class SF6/VCB Type (1 Incomer + 2 Breaker + 1 Outgoing)

Schenider Make ABB Make Siemens Make MEI


Sl.
Materials Unit Rate
No
Qty Amt Qty Amt Qty Amt Qty Amt

RMU (3 Way), One Incomer + Two Breakers + One Will be Will be Will be Will be Will be
1 No 1 1 1 1
out going (2OD + 2VL), 350 MVA, 630Amps intimated intimated intimated intimated intimated
Bed Conceting with CC 1:2:4 as per Labour
2 Cmt 5084 0.15 762.6 0.37 1881.08 0.53 2694.52 0.64 3253.76
Charges
Foundation with Reinforcement CC 1:2:4 as per
3 Cmt 5084 0.65 3304.6 1.44 7320.96 0.56 2847.04 0 0
Labour Charges
Providing Reinforcement as per Labour Charges
4 Kgs 60.1 40 2403.2 14 841.12 23 1381.84 0 0
Item No. 28.1
Providing Plinth with CC 1:2:4 on the Stone
5 Cmt 5084 0 0 0 0 0 0 0.08 406.72
Masonary

6 Construction of Stone Masonary Cmt 3829 0 0 0 0 0 0 0.57 2182.53

Supplying of Frame of MS Channel 100x50mm


7 Kgs 50 50 2500 50 2500 50 2500 50 2500
and MS angle 40x40x5mm welding etc., complete.

Rod type earthing with 40 mm Dia, 3 Mtrs long


8 No 2000 2 4000 2 4000 2 4000 2 4000
MS rod as per specification & drawing (enclosed)

Lettering the RMU with enamel paint and also


9 writing single line diagram of each panel, caution No 596 1 596 1 596 1 596 1 596
Board, Danger Board etc., including cost of Paint,

Total cost of material.(Excluding Item No.1) 13566.4 17139 14019.4 12939.01

Labour Charges

Earth Excavation for R.M.U. Foundation


1 depositing of earth on bank up to a lead of 50 cmt 178 1.29 229.62 3.33 592.74 2.63 468.14 5.72 1018.16
mtrs and with a lift up to 1.5 mtrs
Labour charges for Fixing foundation frame of MS
channel 100X50mm and MS angle 40X40X5mm
2 No. 2836 4 11344 4 11344 4 11344 4 11344
welding, fixing in concrete, aligning the RMU on
foundation bed, assembly of units, connecting
Labour Charges 11574 11937 11812 12362

a) Casual 11574 11937 11812 12362

b) Regular 2315 2387 2362 2472

Total cost of material.(Excluding RMU) 27455 31463 28194 27774

Note:-

The measurements for Earth work and concreting works have been provision as per the dimensions of the equipments of makes which are in use at
1
present in BESCOM. Detail for the measurement are furnished in the data sheet furnished in Page No. ………..

2 While preparing estimates for turnkey / total turnkey projects please refere to Sl. No. …….. To general guidelines vide a to …. page No. ……. To ……..

3 Revised Cost Data Sheet will be furnished after the rates for CSS, RMU etc. are finalised by the committee.
COST DATA SHEET-31
Erection of 3 Phase, 11kV/433V, 250 kVA Single Pole Mounted Distribution Transformer on 11.0 Mtr Spun Pole With
3 GOS System

Material cost Labour Cost


Sl No Materials Unit Qty
Rate Amt Rate Amt

1 Spun pole 11.0 Mtr Long No 1 15800 15800 2353 2353

2 Single Pole Transformer Structure Kit for 250kVA Set 1 23035 23035 2033 2033

3 HT Single Top Support with bolts, nuts & washers Sets 9 89 801 64 576

4 11kV Pin Insulator with pins Nos 9 94 846 0 0

5 Rabbit ACSR Conductor for jumps Mtrs 50 33.68 1684 0 0

6 Alkathene Tube 19mm Dia and in coils of 30 Mtrs Coils 2 500 1000 0 0

7 Concreting materials for 11 Mtrs Spun Pole

a) Base concreting 1:4:8, 1000x1000x150mm Each 1 704 704 0 0

b) Pole concreting 1:2:4, 1000x1000x2500 mm Each 1 11378 11378 0 0

c) Coping 1:2:4 (as per actuals) Each 1 1050 1050 0 0

8 GI Wire 10 SWG Kgs 5 57.7 288 0 0

9 Guy Wire 7/10 SWG Kgs 10 56.267 563 0 0

10 GI Pipe 100 mm Dia Mtrs 10 1143 11430 0 0


11 PVC Pipe 150 mm Dia Mtrs 20 291 5820 0 0
12 PVC Bend 150 mm Dia Nos 8 200 1600 0 0
13 PVC Pipe 25mm Dia Mtrs 40 27 1080 0 0
11kV/433V, 250kVA, 3 Phase, 50 Cys
14 No 1 228340 228340 1365 1365
Distribution Transformer with oil
15 11kV Solid Core Type HG Fuse Unit Set/3 Nos 1 827 827 423 423
16 11kV, 200Amps, Single Break GOS Nos 3 6951 20853 636 1908

Single
Earthing materials pipe type for grounding as per
Electrode
17 Drawing No. BESCOM/GM/CP/15 & 34/Dt: 3 1277 3831 573 1719
with
24.10.07.
accessories

a) LT Distribution Box for 250kVA with MCCB No 1 16705 16705 455 455

b) LT Wiring (From DTC to LT Line via Metering


No 1
Box & LT Protection Kit) SINGLE CIRCUIT

i. Al Lead Wire - 240 Sqmm Mtrs 45 199 8955


ii. Copper lugs - 240 Sqmm Nos 12 184 2208

18 iii. PG Clamps - Rabbit to 240 Sqmm Nos 4 307 1228 728 728
iv. Spacers for DTC Wiring Nos 8 38 304
v. Fish Plate with necessary Clamps,bolts & nuts
Nos 2 155 310
etc complete (Galvanised)
c) LT Metering box with CTs and necessary wiring
No 1 5080 5080 514 514
for housing ETV Meter (Please see CDS-42)
d) LT Electronic Tri-Vector Meter 5A, Class-
No 1 2250 2250 631 631
0.5/1.0 accuracy
19 11kV Lightning Arester, Metal Oxide, 9kV, 5kA Set/3 Nos 1 2070 2070 71 71

20 PVC Insulation Tape in rolls of 10 mtrs Roll 3 10 30 0 0


21 Horizontal Cross Arms nos 4 316 1264 81 324
22 MS Fish plate Nos 9 51 459 20 180

Caution/Danger Board as per Drawing No.


23 No 1 120 120 48 48
BESCOM/GM/CP/40/Dt: 24.10.07

Anti Climbing Device (12mtrs/1Kg GI Barbed


24 Kg 2 64 128 25 50
Wire) Lumpsum
Total cost of Material 372041
25 Labour Charges
a) Casual 13378
b) Regular 2676
Total Cost in Rs 388095
COST DATA SHEET - 30
Erection of 3 Phase, 11kV/433V, 100kVA BEE 3 Star Rated Single Pole Mounted Transformer
Centre on 9 Mtrs RCC Pole (Square Section)
Sl. Material cost Labour Cost
Materials Unit Qty
No Rate Amt Rate Amt

1 9 Mtr long RCC pole (Square Section) No 1 7210 7210 1060 1060

2 11kV Pin Insulators with pins Nos 3 94 282 0 0

3 45kN Disc Insulator Nos 3 290 870 0 0

4 Guy Set Complete Set 1 742 742 354 354


Single pole TC set suitable for 100 kVA
5 Set 1 6129 6129 1016 1016
Transformer
11kV/433V, 100kVA, 3 Phase, 50 Cys
6 Distribution Transformer BEE-3 Star Rated with No 1 121422 121422 910 910
Oil

Earthing materials pipe type for grounding as


7 per Drawing No. BESCOM/GM/CP/15 & 34/Dt: Nos 3 1277 3831 573 1719
24.10.07.

8 Providing Concreting for 9 mtr RCC Pole 0

a) Base concreting 1:4:8, 500x650x150 mm Each 1 298 298 0 0

b) Pole concreting 1:2:4, 500x500x1700 Each 1 3214 3214 0 0

c) Coping 1:2:4 (as per actuals) Each 1 444 444 0 0

Concreting materials for Guy sets (without


9 No 1 158 158 0 0
cement )

10 GI Wire 8 SWG Kgs 5 54.67 273.35 0 0

11 Guy Wire 7/10 SWG Kgs 10 57.7 577 0 0

11kV Lightning Arester, Metal Oxide


12 Set/3 Nos 1 2070 2070 71 71
9kV, 5kA

a) LT Protection Kit No 2 1602 3204 205 410

b) LT Distribution Box for 100kVA with MCB No 1 16705 16705 455 455

c) LT Wiring (From DTC to LT Line Through


Merering Box & LT Protection Kit/LT No 1
Distribution Box) SINGLE CIRCUIT

i. Al Lead Wire - 120 Sqmm Mtrs 45 108 4860

ii. Copper lugs - 120 Sqmm Nos 12 77 924


13
iii. PG Clamps - Rabbit to 120 Sqmm Nos 4 204 816 568 568

iv. Spacers for DTC Wiring Nos 8 38 304

v. Fish Plate with necessary Clamps, bolts &


Nos 2 155 310
nuts etc complete (Galvanised)
d) LT Metering box with CTs and necessary
wiring for housing ETV Meter (Please see CDS- No 1 4918 4918 514 514
42)
e) LT Electronic Tri-Vector Meter 5A, Class-
No 1 2250 2250 631 631
0.5/1.0 accuracy

14 11kV Solid Core Type HG Fuse Unit Set/3 Nos 1 827 827 423 423

15 11kV, 200Amps, Single Break GOS Nos 1 6951 6951 636 636

Caution/Danger Board as per Drawing No.


16 No 1 120 120 48 48
BESCOM/GM/CP/40/ Dt: 24.10.07
Anti Climbing Device (12mtrs/1Kg GI Barbed
17 Kg 1 64 64 25 25
Wire) Lumpsum
18 Total Material Cost

a) With LT Distribution Box 186569

b) With LT Protection Kit 173068

19 Labour Charges for LT Distribution Box for LT Protection Kit

a) Casual 8430 8385


b) Regular 1686 1677

Total
Total Cost for Erection of a Single Pole Mounted 100kVA Transformer with
196685
LT Distribution Box in Rs
Total Cost for Erection of a Single Pole Mounted 100kVA Transformer with
183130
LT Protection KIT in Rs
COST DATA SHEET - 29
Erection of 3 Phase, 11kV/433V, 63kVA BEE 3 Star Rated Single Pole Mounted Transformer
Centre on 9 Mtrs RCC Pole (Square Section)
Material cost Labour Cost
Sl.
Materials Unit Qty
No Rate Amt Rate Amt

1 9 Mtr long RCC pole (Square Section) No 1 7210 7210 1060 1060

2 11kV Pin Insulators with pins Nos 3 94 282 0 0

3 45kN Disc Insulator Nos 3 290 870 0 0

4 Guy Set Complete Set 1 742 742 354 354


Single pole TC set suitable for 63 kVA
5 Set 1 4088 4088 1016 1016
Transformer
11kV/433V, 63kVA, 3 Phase, 50 Cys
6 Distribution Transformer BEE-3 Star Rated with No 1 93726 93726 682 682
Oil
Single
Earthing materials pipe type for grounding as
Electrode
7 per Drawing No. BESCOM/GM/CP/15 & 34/ 3 1277 3831 573 1719
with
Dt: 24.10.07
accessories
8 Concreting materials for 9 mtr RCC Pole

a) Base concreting 1:4:8, 650x650x150 mm Each 1 298 298 0 0

b) Pole concreting 1:2:4, 500x500x1650 Each 1 3214 3214 0 0

c) Coping 1:2:4 (as per actuals) Each 1 444 444 0 0


Concreting materials for Guy sets (without
9 No 1 158 158 0 0
cement )
10 GI Wire 8 SWG Kgs 5 54.67 273.35 0 0
11 Guy Wire 7/10 SWG Kgs 10 57.7 577 0 0
11kV Lightning Arester, Metal Oxide
12 Set/3 Nos 1 2070 2070 71 71
9kV, 5kA

a) LT Protection Kit for 63 kVA Nos 2 1602 3204 205 410


b) LT Wiring (From DTC to LT Line Through
Merering Box & LT Protection Kit) SINGLE No 1
CIRCUIT
i. Al Lead Wire - 95 Sqmm Mtrs 40 82 3280

ii. Copper lugs - 95 Sqmm Nos 4 71 284

13 iii. PG Clamps - Rabbit to 95 Sqmm Nos 4 105 420 568 568

iv. Spacers for DTC Wiring Nos 8 38 304

v. Fish Plate with necessary Clamps,bolts & nuts


Nos 2 155 310
etc complete (Galvanised)
c) LT Metering box with CTs and necessary
No 1 5224 5224 514 514
wiring for housing ETV Meter (Please see CDS-42)
d) LT Electronic Tri-Vector Meter 5A, Class-
No 1 2250 2250 631 631
0.5/1.0 accuracy
14 11kV Solid Core Type HG Fuse Unit Set/3 Nos 1 827 827 423 423

15 11kV, 200Amps, Single Break GOS Nos 1 6951 6951 636 636

Caution/Danger Board as per Drawing No.


16 No 1 120 120 48 48
BESCOM/GM/CP/40/ Dt: 24.10.07
Anti Climbing Device (12mtrs/1Kg GI Barbed
17 Kg 1 64 64 25 25
Wire) Lumpsum

18 Total material cost 141021

19 Labour Charges
a) Casual 8157
b) Regular 1631

Total cost for Erection of a Single Pole Mounted 63kVA Transformer in Rs 150810
COST DATA SHEET - 28
Erection of 3 Phase, 11kV/433V, 25kVA BEE 3 Star Rated Single Pole Mounted Transformer Centre
on 9 Mtrs RCC Pole (Square Section)
Sl. Material cost Labour Cost
Materials Unit Qty
No
Rate Amt Rate Amt

1 9 Mtr long RCC pole (Square Section) No 1 7210 7210 1060 1060

2 11kV Pin Insulators with pins Nos 3 94 282 0 0

3 45kN Disc Insulator Nos 3 290 870 0 0

4 Guy Set Complete Set 1 742 742 354 354


Single pole TC set suitable for 25 kVA
5 Set 1 4088 4088 1016 1016
Transformer
11kV/433V, 25kVA, 3 Phase, 50 Cys
5 Distribution Transformer BEE-3 Star Rated with No 1 51560 51560 682 682
Oil
Single
Earthing materials pipe type for grounding as
Electrode
7 per Drawing No. BESCOM/GM/CP/15 & 34/ 3 1277 3831 573 1719
with
Dt: 24.10.07
accessories
8 Concreting materials for 9 mtr RCC Pole

a) Base concreting 1:4:8, 650x650x150 mm Each 1 298 298 0 0

b) Pole concreting 1:2:4, 500x500x1650 Each 1 3214 3214 0 0

c) Coping 1:2:4 (as per actuals) Each 1 444 444 0 0


Concreting materials for Guy sets (without
9 No 1 158 158 0 0
cement)
10 GI Wire 8 SWG Kgs 5 54.67 273.35 0 0

11 Guy Wire 7/10 SWG Kgs 10 57.7 577 0 0


11kV Lightning Arester, Metal Oxide
12 Set/3 Nos 1 2070 2070 71 71
9kV, 5kA

a) LT Protection Kit for 25 kVA No 1 1602 1602 205 205


b) LT Wiring (From DTC to LT Line Through
Metering Box & LT Protection Kit) SINGLE No 1
CIRCUIT
i. Al Lead Wire - 50 Sqmm Mtrs 25 45 1125

ii. Copper lugs - 50 Sqmm Nos 4 30 120

13 iii. PG Clamps - Rabbit to 50 Sqmm Nos 4 66 264 568 568

iv. Spacers for DTC Wiring Nos 8 38 304

v. Fish Plate with necessary Clamps,bolts & nuts


Nos 2 155 310
etc complete (Galvanised)
c) LT Metering box with CTs and necessary
No 1 5662 5662 514 514
wiring for housing ETV Meter (Please see CDS-42)
d) LT Electronic Tri-Vector Meter 5A, Class-
No 1 2250 2250 631 631
0.5/1.0 accuracy
14 11kV Solid Core Type HG Fuse Unit Set/3 Nos 1 827 827 423 423

15 11kV, 200Amps, Single Break GOS Nos 1 6951 6951 636 636

Caution/Danger Board as per Drawing No.


16 No 1 120 120 48 48
BESCOM/GM/CP/40/ Dt: 24.10.07
Anti Climbing Device (12mtrs/1Kg GI Barbed
17 Kg 1 64 64 25 25
Wire) Lumpsum

18 Total Material Cost 95216.2

Labour Charges

a) Casual 7952

b) Regular 1590

Total cost for erection of a single pole mounted 25kVA Transformer in Rs 104759
COST DATA SHEET - 27
Erection of 3 Phase, 11kV/433V, 250kVA 3 Star rated Distribution Transformer Centre Using
DPTS

250 KVA
Sl.No Particulars Unit Qty Material cost Labour Cost
Rate Amt Rate Amt
1 Part-A: TRANSFORMER

a) 9 Mtr RCC DP Transformer Structure (Using


No 1 24575 24575 4238 2999
9 Mtr RCC Poles)
b) 8 Mtr RCC DP Transformer Structure (Using
No 1 21395 21395 3816 2703
8 Mtr RCC Poles)

2 11kV Pin Insulators Sets 3 94 282 0 0

3 45kN Disc Insulators Sets 3 290 870 0 0

4 Guy Set Complete Nos 4 742 2968 354 1416


11kV/433V, 250kVA, 3 Phase, 50 Cys
5 No 1 277240 277240 1365 1365
Distribution Transformer with oil
Single
Earthing materials pipe type for grounding as
Electrode
6 per Drawing No. BESCOM/GM/CP/15 & 34/ 3 1277 3831 573 1719
with
Dt: 24.10.07
accessories
Caution/Danger Board as per Drawing No.
7 No 1 120 120 48 48
BESCOM/GM/CP/40/ Dt: 24.10.07
Anti Climbing Device (12mtrs/1Kg GI Barbed
8 Kgs 2 64 128 25 50
Wire) Lumpsum
9 Concreting for Guy sets without cement Nos 4 158 632 0 0

10 GI Wire 8 SWG Kgs 5 54.67 273 0 0


11 Guy wire 7/10 SWG Kgs 10 56.26 563 0 0

Total using 9 mtr Poles 311482 7597

Total using 8 mtr Poles 308302 7301

12 Labour Charges

i) using 9 mtr Poles

a) Casual 7597

b) Regular 1519

ii) using 8 mtr poles

a) Casual 7301

b) Regular 1460

13 Total for Part-A

I) Using 9 mtr Poles 320598


ii) using 8 mtr poles 317063
Part-B:
11kV Lightning Arester, Metal Oxide
14 Set of 3 Nos 1 2070 2070 71 71
9kV, 5kA
15 Labour Charges

a) Casual 71

b) Regular 14

16 Total for Part-B 2155

Part-C: SWITCH GEAR

a) LT Distribution box for 250kVA with MCCB No 1 16705 16705 455 455

b) LT Wiring (From DTC to LT Line via Metering


No 1
Box & LT Protection Kit) SINGLE CIRCUIT

i. Al Lead Wire - 240 Sqmm Mtrs 45 199 8955

ii. Copper lugs - 240 Sqmm Nos 12 184 2208

17 iii. PG Clamps - Rabbit to 240 Sqmm Nos 4 307 1228 644 644

iv. Spacers for DTC Wiring Nos 8 38 304

v. Fish Plate with necessary Clamps,bolts &


Nos 2 155 310
nuts etc complete (Galvanised)
c) LT Metering box with CTs and necessary
wiring for housing ETV Meter (Please see CDS- No 1 5080 5080 514 514
42)
d) LT Electronic Tri-Vector Meter 5A, Class-
Nos. 1 2250 2250 631 631
0.5/1.0 accuracy

18 11kV Solid Core Type HG Fuse Unit Set/ 3 nos 1 827 827 423 423

19 11kV, 200Amps, Single Break GOS No 1 6951 6951 636 636

Total Cost (Material) 44818

20 Labour Charges

a) Casual 3303

b) Regular 661

21 Total for Part-C 48782

22 Total (A+B+C)

1) Using 9 mtr Poles 371535

Labour Charges:

a) Casual 10971

b) Regular 2194

2) Using 8 mtr Poles 368000

Labour Charges:

a) Casual 10675

b) Regular 2135
Note: Provision for actual quantity of additional materials viz 45kN Disc Insulator, 11 kV Pin Insulators ACSR/AAA
Conductor, Transparent Alkathine Tube, PG Clamps and Terminal Connectors etc. Whenever required may be made in
the estimate separately for
While preparing estimates for turnkey / total tunkey projects please refer to Sl. No. ......... of General Guidelines
1
vide a to .... in Page No. ...........
COST DATA SHEET -26
Erection of 3 Phase, 11kV/433 V, 100kVA BEE – 3 Star Rated Distribution Transformer Centre Using
DPTS

100 KVA

Sl No Particulars Unit Qty Material cost Labour Cost

Rate Amt Rate Amt

1 Part-A: TRANSFORMER

a) 9 Mtr RCC DP Transformer Structure (Using 9


No 1 24575 24575 4238 4238
Mtr RCC Poles)
b) 8 Mtr RCC DP Transformer Structure (Using 8
No 1 21395 21395 3816 3816
Mtr RCC Poles)

2 11kV Pin Insulators Sets 3 94 282 0 0

3 45kN Disc Insulators Sets 3 290 870 0 0

4 Guy Set Complete Nos 4 742 2968 354 1416


11kV/433V, 100kVA, 3 Phase 50 Cys
5 Distribution Transformer BEE - 3 Star Rated with No 1 121422 121422 910 910
Oil
Single
Earthing materials pipe type for grounding as per
Electrode
6 Drawing No. BESCOM/GM/CP/15 & 34/ Dt: 3 1277 3831 573 1719
with
24.10.07
accessories

Caution/Danger Board as per Drawing No.


7 No 1 120 120 48 48
BESCOM/GM/CP/40/ Dt: 24.10.07
Anti Climbing Device (12mtrs/1Kg GI Barbed
8 Kgs 2 64 128 25 50
Wire) Lumpsum

9 Concreting for Guy sets without cement Nos 4 158 632 0 0

10 GI Wire 8 SWG Kgs 5 54.67 273 0 0


11 Guy wire 7/10 SWG Kgs 10 56.26 563 0 0

Total using 9 mtr Poles 155664 8381

Total using 8 mtr Poles 152484 7959

12 Labour Charges

I) using 9 mtr Poles

a) Casual 8381

b) Regular 1676

ii) using 8 mtr poles

a) Casual 7959

b) Regular 1592

13 Total for Part-A

I) Using 9 mtr Poles 165721

ii) using 8 mtr poles 162035

Part-B:
11kV Lightning Arester, Metal Oxide
14 Set of 3 Nos 1 2070 2070 71 71
9kV, 5kA
15 Labour Charges

a) Casual 71
b) Regular 14

16 Total for Part-B 2155

Part-C: SWITCH GEAR

a) LT Protection Kit Nos 2 1602 3204 205 410

b) LT Distribution box for 100 kVA with MCB No 1 16705 16705 455 455

c) LT Wiring (From DTC to LT Line Through


Merering Box & LT Protection Kit/LT Distribution No 1
Box) SINGLE CIRCUIT

i. Al Lead Wire - 120 Sqmm Mtrs 45 108 4860

ii. Copper lugs - 120 Sqmm Nos 12 77 924


17

iii. PG Clamps - Rabbit to 120 Sqmm Nos 4 204 816 568 568

iv. Spacers for DTC Wiring Nos 8 38 304

v. Fish Plate with necessary Clamps,bolts & nuts


Nos 2 155 310
etc complete (Galvanised)

d) LT Metering box with CTs and necessary wiring


No 1 4918 4918 514 514
for housing ETV Meter (Please see CDS-42)

e) LT Electronic Tri-Vector Meter 5A, Class-


Nos 1 2250 2250 631 631
0.5/1.0 accuracy

18 11kV Solid Core Type HG Fuse Unit Set/3 Nos 1 827 827 423 423

19 11kV, 200Amps, Single Break GOS No 1 6951 6951 636 636

With LT Protection
With Distribution Box
kit

Total Cost (Material) 25364 38865

20 Labour Charges

a) Casual 3182 3227

b) Regular 636 645

21 Total for Part-C 29182 42737

22 Total (A+B+C)

1) Using 9 mtr Poles 197059 210614

Labour Charges:

a) Casual 11634 11679

b) Regular 2327 2336

2) Using 8 mtr Poles 193372 206927

Labour Charges:

a) Casual 11212 11257

b) Regular 2242 2251

Note: Provision for actual quantity of additional materials viz 45kN Disc Insulator, 11kV Pin Insulators ACSR/AAA Conductor,
Transparent Alkathine Tube, PG Clamps and Terminal Connectors etc. Whenever required may be made in the estimate
separately for
COST DATA SHEET -25
Erection of 3 Phase, 11kV/433V, 63kVA BEE – 3 Star Rated Distribution Transformer Centre
Using DPTS

63 KVA
Sl
Particulars Unit Qty Material Cost Labour Cost
No
Rate Amt Rate Amt

1 Part-A: TRANSFORMER

a) 9 Mtr RCC DP Transformer Structure (Using 9


No 1 22532 22532 4115 4115
Mtr RCC Poles)

b) 8 Mtr RCC DP Transformer Structure (Using 8


No 1 19352 19352 3560 3560
Mtr RCC Poles)

2 11kV Pin Insulators Sets 3 94 282 0 0

3 45kN Disc Insulators Sets 3 290 870 0 0

4 Guy Set Complete Nos 4 742 2968 354 1416

11kV/433V, 63kVA, 3 Phase, 50 Cys Distribution


5 No 1 93726 93726 682 682
Transformer BEE - 3 Star Rated with Oil

Single
Earthing materials pipe type for grounding as per
Electrode
6 Drawing No. BESCOM/GM/CP/15 & 34/ Dt: 3 1277 3831 573 1719
with
24.10.07
accessories

Caution/Danger Board as per Drawing No.


7 No 1 120 120 48 48
BESCOM/GM/CP/40/ Dt: 24.10.07
Anti Climbing Device (12mtrs/1Kg GI Barbed
8 Kgs 2 64 128 25 50
Wire) Lumpsum

9 Concreting for Guy sets without cement Nos 4 158 632 0 0

10 GI Wire 8 SWG Kgs 5 54.67 273 0 0


11 Guy wire 7/10 SWG Kgs 10 56.26 563 0 0

Total using 9 mtr Poles 125925 8030

Total using 8 mtr Poles 122745 7475

12 Labour Charges

i) using 9 mtr Poles

a) Casual 8030

b) Regular 1606

ii) using 8 mtr Poles

a) Casual 7475

b) Regular 1495

13 Total for Part-A

I) Using 9 mtr Poles 135561

ii) using 8 mtr Poles 131715

Part-B:
11kV Lightning Arester, Metal Oxide
14 Set of 3 Nos 1 2070 2070 71 71
9kV, 5kA

15 Labour Charges

a) Casual 71

b) Regular 14

16 Total for Part-B 2155

Part-C: SWITCH GEAR

a) LT Protection Kit for 63 kVA Nos 2 1602 3204 205 410

b) LT Wiring (From DTC to LT Line Through


Metering Box & LT Protection Kit) SINGLE No 1
CIRCUIT

i. Al Lead Wire - 95 Sqmm Mtrs 40 82 3280

ii. Copper Lugs - 95 Sqmm Nos 4 71 284

17 iii. PG Clamps - Rabbit to 95 Sqmm Nos 4 105 420 568 568

iv. Spacers for DTC Wiring Nos 8 38 304

v. Fish Plate with necessary Clamps,bolts & nuts


Nos 2 155 310
etc complete (Galvanised)

c) LT Metering box with CTs and necessary wiring


No 1 5224 5224 514 514
for housing ETV Meter (Please see CDS-42)

d) LT Electronic Tri-Vector Meter 5A, Class-


No 1 2250 2250 631 631
0.5/1.0 accuracy

18 11kV Solid Core Type HG Fuse Unit Set/ 3 nos 1 827 827 423 423

19 11kV, 200Amps, Single Break GOS No 1 6951 6951 636 636

Total Cost (Material) for Part-C 23054

20 Labour Charges

a) Casual 3182

b) Regular 636

21 Total for Part-C 26872

22 Total (A+B+C)

1) Using 9 mtr Poles 164589

Labour Charges:

a) Casual 11283

b) Regular 2257

2) Using 8 mtr Poles 160743

Labour Charges:

a) Casual 10728

b) Regular 2146
Note: Provision for actual quantity of additional materials viz 45kN Disc Insulator, 11kV Pin Insulators ACSR/AAA
Conductor, Transparent Alkathine Tube, PG Clamps and Terminal Connectors etc. Whenever required may be made in the
estimate separately for
COST DATA SHEET - 24
Erection of 3 Phase, 11kV/433V, 25kVA BEE – 3 Star Rated Distribution Transformer Centre
Using DPTS
25 KVA
Sl
Particulars Unit Qty Material Cost Labour Cost
No
Rate Amt Rate Amt

1 Part-A: TRANSFORMER

a) 9 Mtr RCC DP Transformer Structure (Using 9


No 1 22532 22532 4115 4115
Mtr RCC Poles)

b) 8 Mtr RCC DP Transformer Structure (Using 8


No 1 19352 19352 3560 3560
Mtr RCC Poles)

2 11kV Pin Insulators Sets 3 94 282 0 0

3 45kN Disc Insulators Sets 3 290 870 0 0

4 Guy Set Complete Nos 4 742 2968 354 1416

11kV/433V, 25KVA, 3 Phase, 50 Cys Distribution


5 No 1 51560 51560 682 682
Transformer BEE-3 Star Rated with Oil

Single
Earthing materials pipe type for grounding as per
Electrode
6 Drawing No. BESCOM/GM/CP/15 & 34/ Dt: 3 1277 3831 573 1719
with
24.10.07
accessories
Caution/Danger Board as per Drawing No.
7 No 1 120 120 48 48
BESCOM/GM/CP/40/ Dt: 24.10.07
Anti Climbing Device (12mtrs/1Kg GI Barbed
8 Kgs 2 64 128 25 50
Wire) Lumpsum

9 Concreting for Guy sets without cement Nos 4 158 632 0 0

10 GI Wire 8 SWG Kgs 5 54.67 273.35 0 0


11 Guy wire 7/10 SWG Kgs 10 56.26 563 0 0

Total using 9 mtr Poles 83759 8030

Total using 8 mtr Poles 80579 7475

12 Labour Charges

i) using 9 mtr Poles

a) Casual 8030

b) Regular 1606

ii) using 8 mtr Poles

a) Casual 7475

b) Regular 1495

13 Total for Part-A

I) Using 9 mtr Poles 93395

ii) using 8 mtr Poles 89549

Part-B:
11kV Lightning Arester, Metal oxide,
14 Set of 3 Nos 1 2070 2070 71 71
9kV, 5kA
15 Labour Charges

a) Casual 71

b) Regular 14

16 Total for Part-B 2155

Part-C: SWITCH GEAR

a) LT Protection Kit for 25 kVA No 1 1602 1602 205 205

b) LT Wiring (From DTC to LT Line Through


Metering Box & LT Protection Kit) SINGLE No 1
CIRCUIT

i. Al Lead Wire - 50 Sqmm Mtrs 25 45 1125

ii. Copper Lugs - 50 Sqmm Nos 4 30 120

17 iii. PG Clamps - Rabbit to 50 Sqmm Nos 4 66 264 568 568

iv. Spacers for DTC Wiring Nos 8 38 304

v. Fish Plate with necessary Clamps,bolts & nuts


Nos 2 155 310
etc complete (Galvanised)

c) LT Metering box with CTs and necessary wiring


No 1 5662 5662 514 514
for housing ETV Meter (Please see CDS-42)
d) LT Electronic Tri-Vector Meter 5A, Class-
No 1 2250 2250 631 631
0.5/1.0 accuracy
18 11kV Solid Core Type HG Fuse Unit Set/3 Nos 1 827 827 423 423

19 11kV, 200Amps, Single Break GOS No 1 6951 6951 636 636

Total Cost (Material) for Part-C 19415

20 Labour Charges

a) Casual 2977

b) Regular 595

21 Total for Part-C 22987

22 Total (A+B+C)

1) Using 9 mtr Poles 118538

Labour Charges:

a) Casual 11078

b) Regular 2216

2) Using 8 mtr Poles 114692

Labour Charges:

a) Casual 10523

b) Regular 2105
Note: Provision for actual quantity of additional materials viz 45kN Disc Insulator, 11kV Pin Insulators ACSR/AAA
Conductor, Transparent Alkathine Tube, PG Clamps and Terminal Connectors etc. Whenever required may be made in the
estimate separately for
COST DATA SHEET -60

Erection of 3 Pole Structure With 9 Mtr PSCC Poles of 300Kg WL

SL.
Paritculars Unit Qty Material cost Labour Cost
No

Part-A: LINES Rate Amt Rate Amt

3 Pole Structure complete using 9 Mtrs PSCC Poles of


1 Set 1 23357 23357 6271 6271
300kg WL ( Including Cost of Poles)

2 Spiral Earth Electrode Nos 3 207 621 55 165

3 Guy Set With No.15 Strain Insulator Complete Sets 3 742 2226 354 1062

4 45kN Disc Insulators Nos 6 290 1740 0 0

5 11kV Pin Insulators with GI Pins Nos 3 94 282 0 0

6 Concrete for Guy set (without cement) Nos 3 158 474 0 0

Caution/Danger Board as per Drawing No.


7 Nos 2 120 240 49 98
BESCOM/GM/CP/40/Dt: 24.10.07

Anti Climbing Device (12mtrs/1Kg GI Barbed Wire)


8 Kgs 3 64 192 25 75
Lumpsum

9 Total Material cost 29132

10 Labour Charges

a) Casual 7671

b) Regular 1534

Total Cost/Unit in Rs. 38337

Note:
1) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET -59
Providing 2 Pole Structrues at the Tapping Point Using 9Mtrs PSCC Poles of 300.Kg WL

SL.
Paritculars Unit Qty Material cost Labour Cost
No

Part-A: LINES Rate Amt Rate Amt

1 DP Structure using 9 Mtrs PSCC Poles of 300Kg WL Set 1 13184 13184 3252 3252

2 45kN Disc Insulators Nos 6 290 1740 0 0

3 Guy Set Complete Sets 2 742 1484 354 708

4 Spiral Earth Electrode Nos 2 207 414 55 110

5 Concrete for Guy Set (without Cement) Nos 2 158 316 0 0

Caution/Danger Board as per Drawing No.


6 No 1 120 120 49 48
BESCOM/GM/CP/40/Dt: 24.10.07

Anti Climbing Device (12mtrs/1Kg GI Barbed Wire)


7 Kgs 2 64 128 25 50
Lumpsum

Total Part A 17386 4168

Part-B: SWITCH GEAR

9 11kV 400A D/B GOS Set 1 15637 15637 706 706

10 H-Frame for mounting GOS No 1 2895 2895 191 191

11 DOLO Cut Out Set/3 Nos 1 4494 4494 423 423

Total Part B 23026 1320

Total Material cost (A+B) 40412

Labour Charges

a) Casual 5488

b) Regular 1098

Total Cost of Estimate using 9 Mtrs PSCC PoleoF 300Kg WL 46998

Note: 1) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 58

Running Single Circuit 11 kV, 3-phase Power Line on 9.0 Mtr Supports Using RABBIT ACSR Conductorand using PSCC poles
of 300 Kg WL for dead ends and Anchor Points, With an Average Span of 40 Mtrs in Vertical Configuration in Congested Areas

Material cost Labour Cost


SL.
Particulars Unit Qty
No
Rate Amt Rate Amt

PSCC Pole - 9 Mtrs Long, 300 kg WL (for Deadend,


1 Nos 1 4578 4578 1060 1060
Anchor points)

PSC Pole -9 Mtrs Long, 200 kg WL (for Intermediate


2 Nos 23 3401 78223 1060 24380
Poles)

3 DP Structure using 9 Mtrs RCC poles Set 1 13184 13184 3252 3252

Special cross arm with cross arm for EG Stirrups,


4 Sets 23 1122 25806 316 7268
braces, clamps, bolts nuts and washers complete

5 11kV ceramic Pin Insulators with GI Pins Nos 69 94 6486 0 0

6 45kN Disc Insulators Nos 6 290 1740 0 0

7 Guy Set Complete Sets 9 742 6678 354 3186

8 Rabbit ACSR Conductor Kms 3.045 33676 102543 2608 7941

9 Spiral Earth Electrode Nos 26 207 5382 55 1430

10 EG Stirrups with GI wire lacing Set of 2 No's 370 424 156880 99 36630

11 Concreting Materials for guy sets (Without Cement) Nos 9 158 1422 0 0

Anti Climbing Device (12mtrs/1Kg GI Barbed Wire)


12 Kgs 26 64 1664 25 650
Lumpsum

Total 404586 85797

13 Labour charges

a) Casual 85797

b) Regular 17159

Total Cost/Km in Rs. 507543

Note: Item 4 includes, the following


a) Special cross arms 50x50x6 mm MS 0.715 mtr long 3-Nos
b) Support piece for fixing EG stirrup 50x50x6 mm MS Angle 0.865 mtr long - 1 No
c) Brace 50x50x6 mm MS Angle 0.850 mtr long - 1 No
d) 50x6 mm Flat 1.8 mtr, long - 1No
e) RCC Pole Clamps - 5 Nos
f) Cross Arm for fixing EG Stirrup - 1 No

1) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 57
Running LT, 3-Phase 5 Wire Power Line with Continuous Earth Wire on 9.0 Mtr Supports Using RABBIT ACSR for Phase and
Neutral, and WEASEL Conductor for Street Light and 8 SWG GI Wire for Continuous Earth Wire with an Average Span of 40 Mtrs in
Vertical Configuration and using PSCC poles of 300 Kg WL for dead ends and Anchor Points

SL. Material cost Labour Cost


Particulars Unit Qty
No Rate Amt Rate Amt

PSCC Pole - 9 Mtrs Long, 300 kg WL (for Deadend,


1 Nos 6 4578 27468 1060 6360
Anchor points)

2 PSC Pole -9 Mtrs Long, 200 kg WL (for Intermediate Poles) Nos 19 3401 64619 1060 20140

Fabricated Vertical Cross Arms with pole, clamps, bolts,


3 Sets 30 626 18780 287 8610
nuts and washers
4 1.1kV Pin Insulators with GI Pins Nos 100 38 3800 0 0

5 No.8 Strain Insulators Nos 50 14 700 0 0

6 Guy Set Complete Sets 12 723 8676 354 4248

7 Rabbit ACSR Conductor Kms 4.06 33676 136725 2608 10588

8 Weasel ACSR Conductor Kms 1.015 20100 20402 1913 1942

1.015
9 No.8 SWG GI wire for continuous earth wire Kms 54.674 5631 1913 1942
(103 kgs)

10 8 SWG GI wire for guard loops Kgs 26 54.674 1422 0 0

11 Spiral Earth Electrode Nos 25 207 5175 55 1375

12 Concreting Materials for guy sets (Without Cement) Nos 8 140 1120 0 0

SMC Street Lighting Metering Box with Automatic Control


13 Swith, Contactors with Single Phase 5-30 Amps meter & Nos 1 6500 6500 565 565
50/5A CT including wiring
14 PVC Pipe 40 mm Dia Mtrs 6 50 300 0 0

15 PVC Insulated wire 25 Sqmm Single Core Multi Stranded Mtrs 25 32 800 0 0

Anti Climbing Device (12mtrs/1Kg GI Barbed Wire)


16 Kgs 25 64 1600 25 625
Lumpsum

Total 303717 56395

17 Labour charges

a) Casual 56395

b) Regular 11279

Total Cost/Km in Rs. 371390

Note:
1) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 56
Running LT, 3-Phase 5 Wire for Power Line on 9.0 Mtr Supports Using RABBIT ACSR Conductor for Phase and Neutral, and
WEASEL Conductor or Street Light with an Average Span of 40 Mtrs and using PSCC poles of 300 Kg WL for dead ends and
Anchor Points (For Cities, Towns and Residential Layouts)

Material cost Labour Cost


SL.
Particulars Unit Qty
No
Rate Amt Rate Amt

PSCC Pole - 9 Mtrs Long, 300 kg WL (for Deadend,


1 Nos 6 4578 27468 1060 6360
Anchor points)
PSC Pole - 9 Mtrs Long, 200 kg WL (for Intermediate
2 Nos 19 3401 64619 1060 20140
Poles)
LT 4 Pin cross arms, with pole clamps, bolts, nuts and
3 Sets 7 258 1806 96 672
washers (for PSCC poles)
LT 4 Pin cross arms, with pole clamps, bolts, nuts and
4 Sets 22 258 5676 96 2112
washers (for PSC poles)
LT 2 Pin cross arms, with pole clamps, bolts, nuts (for
5 Sets 7 157 1099 96 672
PSCC poles)

LT 2 Pin cross arms, with pole clamps, bolts, nuts (for


6 Sets 18 157 2826 96 1728
PSC poles)

7 1.1kV Pin Insulators with GI Pins Nos 95 38 3610 0 0

8 No.8 Strain Insulators Nos 50 14 700 0 0

9 Guy Set Complete Sets 10 723 7230 354 3540

10 Rabbit ACSR Conductor Kms 4.06 33636 136562 2608 10588

11 Weasel ACSR Conductor Kms 1.015 20100 20402 1913 1942


12 Spiral Earth Electrode Nos 25 207 5175 55 1375

13 Concreting Materials for guy sets (without Cement) No's 8 158 1264 0 0

SMC Street Lighting Metering Box with Automatic


14 Control Swith, Contactors with Single Phase 5-30 Amps No's 1 6500 6500 565 565
meter & 50/5A CT including wiring

15 PVC Pipe 40 mm Dia Mtrs 6 50 300 0 0


PVC Insulated wire 25 Sqmm Single Core Multi
16 Mtrs 25 32 800 0 0
stranded
Anti Climbing Device (12mtrs/1Kg GI Barbed Wire)
17 Kgs 25 64 1600 25 625
Lumpsum

Total 287637 50319

18 Labour charges

a) Casual 50319

b) Regular 10064

Total Cost/Km in Rs. 348020

Note:
1) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 55
Running LT, 3-Phase 4 Wire Power Line on 9.0 Mtr Supports Using RABBIT ACSR Conductor with an
Average Span of 40 Mtrs and using PSCC poles of 300 Kg WL for dead ends and DP structure

Material cost Labour Cost


SL.
Particulars Unit Qty
No
Rate Amt Rate Amt

1 PSCC Pole - 9 Mtrs Long, 300 kg WL Nos 1 4578 4578 1060 1060

2 PSC Pole - 9 Mtrs Long, 200 kg WL Nos 24 3401 81624 1060 25440

LT 4 Pin cross arms, with pole clamps, bolts, nuts and


3 Set 1 258 258 96 96
washers (for PSCC poles)

LT 4 Pin cross arms, with pole clamps, bolts, nuts and


4 Sets 24 258 6192 96 2304
washers (for PSC poles)

5 1.1kV Pin Insulators with GI Pins Nos 96 38 3648 0 0

6 No.8 Strain Insulators Nos 8 14 112 0 0

7 Guy Set Complete Sets 8 723 5784 354 2832

8 Rabbit ACSR Conductor Kms 4.06 33636 136562 2608 10588

9 Spiral Earth Electrode Nos 25 207 5175 55 1375

10 Concreting materials for guy sets without cement Nos 8 158 1264 0 0

Anti Climbing Device (12mtrs/1Kg GI Barbed Wire)


11 Kgs 25 64 1600 25 625
Lumpsum

Total 246797 44320

12 Labour charges

a) Casual 44320

b) Regular 8864

Total Cost/Km in Rs. 299982

Note: 1) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 54
Running Single Circuit 11 kV, 3-Phase Power Line & 3 Phase 4 Wire Secondary Line on 9.0 Mtr Supports with an Average Span of
40 Mtrs Using RABBIT ACSR conductor for HT & LT Lines and using PSCC poles of 300 Kg WL for dead ends and DP structure

SL. Material cost Labour Cost


Particulars Unit Qty
No
Rate Amt Rate Amt

1 PSCC Pole - 9 Mtrs Long, 300 kg WL Nos 1 4578 4578 1060 1060

2 PSC Pole - 9 Mtrs Long, 200 kg WL No's 23 3401 78223 1060 24380

Horizontal cross arms with clamps, HTST supports,


3 Set 1 377 377 99 99
bolts, nuts and washers (for PSCC poles)

Horizontal cross arms with clamps, HTST supports,


4 Sets 23 377 8671 99 2277
bolts, nuts and washers (for PSC poles)

LT 4 Pin cross arms, with pole clamps, bolts, nuts and


5 Set 1 258 258 96 96
washers (for PSCC poles)

LT 4 Pin cross arms, with pole clamps, bolts, nuts and


6 Sets 24 258 6192 96 2304
washers(for PSC poles)

7 DP Structure with 9 Mtrs PSCC Poles of 300Kg WL Set 1 13184 13184 3252 3252

8 11kV Pin Insulators with GI pins Nos 72 94 6768 0 0

9 1.1kV Pin Insulators with GI Pins Nos 96 38 3648 0 0

10 45kN Disc Insulators Nos 6 290 1740 0 0

11 No.8 Strain Insulators Nos 8 14 112 0 0

12 Guy Set Complete Sets 8 742 5936 354 2832

13 Rabbit ACSR Conductor Kms 7.105 33676 239268 2608 18530

14 PG Clamps for Rabbit conductor Nos 6 76 456 0 0

15 Spiral Earth Electrode Nos 26 207 5382 55 1430

16 Guarding between HT & LT Lines

a) Guarding Materials Span 25 2720 68000 603 15075

b) 4 Pin cross arms with clamps,bolts, nuts and


Sets 25 263 6575 0 0
washers.

17 Concreting materials for guy sets without cement Nos 8 158 1264 0 0

Caution/Danger Board as per Drawing No.


18 Nos 8 120 960 48 384
BESCOM/GM/CP/40/Dt: 24.10.07

Anti Climbing Device (12mtrs/1Kg GI Barbed Wire)


19 Kgs 26 64 1664 25 650
Lumpsum

Total 453256 72369

20 Labour charges

a) Casual 72369

b) Regular 14474

Total Cost/Km in Rs. 540099

Note: 1) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 53
Running Single Circuit 11 kV 3 Phase Power Line and 3 Phase - 4 Wire Secondary Line on 9 Mtr Supports with an Average Span of
50 Mtrs using RABBIT Conductor for HT and WEASEL for LT Lines and using PSCC poles of 300 Kg WL for dead ends and DP
structure

Sl Material cost Labour Cost


Particulars Unit Qty
No
Rate Amt Rate Amt

1 PSCC Pole - 9 Mtrs Long, 300 kg WL Nos 1 4578 4578 1060 1060

2 PSC Pole - 9 Mtrs Long, 200 kg WL Nos 18 3401 61218 1060 19080

11kV Horizontal cross arms with clamps, HTST


3 Set 1 377 377 99 99
Supports, bolts, nuts and washers (for PSCC poles)

11kV Horizontal cross arms with clamps, HTST


4 Sets 18 377 6786 99 1782
Supports, bolts, nuts and washers (for PSC poles)

LT 4 Pin cross arms, with pole clamps, bolts, nuts and


5 Set 1 258 258 96 96
washers (for PSCC poles)

LT 4 Pin cross arms, with pole clamps, bolts, nuts and


6 Sets 19 258 4902 96 1824
washers (for PSC poles)

7 DP Structure with 9 Mtrs PSCC Poles of 300Kg WL Set 1 13184 13184 3252 3252

8 11kV Pin Insulators with GI pins Nos 57 94 5358 0 0

9 1.1kV Pin Insulators with GI Pins Nos 76 38 2888 0 0

10 45kN Disc Insulators Nos 6 290 1740 0 0

11 No.8 Strain Insulators Nos 8 14 112 0 0

12 Guy Set Complete Sets 8 742 5936 354 2832

13 Rabbit ACSR for HT Lines Kms 3.045 33676 102543 2608 7941

14 Weasel ACSR for LT lines Kms 4.06 20100 81606 1913 7767

15 Spiral Earth Electrode Nos 21 207 4347 55 1155

16 Guarding between HT & LT Lines

a) Guarding Materials Span 20 2720 54400 603 12060

b) 4 Pin cross arms with clamps,bolts, nuts and


Sets 20 263 5260 0 0
washers.

17 PG Clamps for Rabbit conductor Nos 6 158 948 0 0

18 Concreting Materials for guy sets Nos 8 120 960 0 0

Caution/Danger Board as per Drawing No.


19 Nos 7 120 840 48 336
BESCOM/GM/CP/40/Dt: 24.10.07

Anti Climbing Device (12mtrs/1Kg GI Barbed Wire)


20 Kgs 21 64 1344 25 525
Lumpsum
Total 359585 59809

21 Labour charges

a) casual 59809

b) Regular * 11962
Total Cost/Km in Rs 431356

Note: 1) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 52
Running Single Circuit 11 kV, 3-Phase Power Line on 9.0 Mtr Supports with an Average Span of 40 Mtrs Using COYOTE ACSR
conductor and PSCC poles of 300 Kg WL for dead ends and DP structure

Material cost Labour Cost


SL.
Particulars Unit Qty
No
Rate Amt Rate Amt

1 PSCC Pole - 9 Mtrs Long, 300 kg WL Nos 1 4578 4578 1060 1060

2 PSC Pole - 9 Mtrs Long, 200 kg WL Nos 22 3401 74822 1060 23320

Horizontal cross arms with clamps, HTST supports,


3 Set 1 377 377 99 99
bolts, nuts and washers (for PSCC poles)
Horizontal cross arms with clamps, HTST supports,
4 Sets 22 377 8294 99 2178
bolts, nuts and washers (for PSC poles)

5 DP Structure with 9 Mtrs PSCC Poles of 300Kg WL Sets 2 13184 26368 3252 6504

6 11kV Pin Insulators with GI pins Nos 69 94 6486 0 0

7 70/90 kN Disc Insulators Nos 12 490 5880 0 0

8 Strain Clamp 3 bolt type for Disc Insulator Nos 12 468 5616 0 0

9 Guy Set Complete Sets 6 742 4452 354 2124

10 Coyote ACSR Conductor Kms 3.045 92708 282296 4555 13870

11 PG Clamps for Coyote Conductor Nos 12 267 3204 0 0

12 Spiral Earth Electrode Nos 27 207 5589 55 1485

Set of 2
13 EG Stirrups with GI wire lacing 23 370 8510 99 2277
Nos

14 Concreting materials for guy sets without cement Nos 6 158 948 0 0

Caution/Danger Board as per Drawing No.


15 Nos 10 120 1200 48 480
BESCOM/GM/CP/40/Dt: 24.10.07

Anti Climbing Device (12mtrs/1Kg GI Barbed Wire)


16 Kgs 27 64 1728 25 675
Lumpsum

Total 440348 54072

17 Labour charges

a) Casual 54072

b) Regular 10814

Total Cost/Km in Rs. 505234

Note: 1) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 51
Running Single Circuit 11 kV, 3-Phase Power Line on 9.0 Mtr Supports with an Average Span of 50 Mtrs Using Rabbit ACSR
Conductor and PSCC poles of 300 Kg WL for dead ends and DP structure

Material cost Labour Cost


SL.
Particulars Unit Qty
No
Rate Amt Rate Amt

1 PSCC Pole - 9 Mtrs Long, 300 kg WL Nos 1 4578 4578 1060 1060

2 PSC Pole - 9 Mtrs Long, 200 kg WL Nos 18 3401 61218 1060 19080

Horizontal cross arms with clamps, HTST supports,


3 Set 1 377 377 99 99
bolts, nuts and washers (for PSCC poles)
Horizontal cross arms with clamps, HTST supports,
4 Set 18 377 6786 99 1782
bolts, nuts and washers (for PSC poles)

5 DP Structure with 9 Mtrs PSCC Poles of 300Kg WL Set 1 13184 13184 3252 3252

6 11kV Pin Insulators with GI pins Nos 57 94 5358 0 0

7 45kN Disc Insulators Nos 6 290 1740 0 0

8 Guy Set Complete Sets 6 742 4452 354 2124

9 Rabbit ACSR Conductor Kms 3.045 33676 102543 2608 7941

10 PG Clamps for Rabbit conductor Nos 6 76 456 0 0

11 Spiral Earth Electrode Nos 21 207 4347 55 1155

Set of
12 EG Stirrups with GI wire lacing 19 370 7030 99 1881
2 Nos

13 Concreting materials for guy sets without cement Nos 6 158 948 0 0

Caution/Danger Board as per Drawing No.


14 Nos 8 120 960 48 384
BESCOM/GM/CP/40/Dt: 24.10.07

Anti Climbing Device (12mtrs/1Kg GI Barbed Wire)


15 Kg 21 64 1344 25 525
Lumpsum

Total 215321 39283

16 Labour charges

a) Casual 39283

b) Regular 7857

Total Cost/Km in Rs. 262461

Note 1) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET -50
Running Single Circuit 11kV, 3 Phase Power Line On 9.0 Mtr Supports With An Average Span Of 40 Mtrs Using Rabbit ACSR
Conductor and PSCC poles of 300 Kg WL for dead ends and DP structure

Material cost Labour Cost


SL.
Particulars Unit Qty
No
Rate Amt Rate Amt

1 PSCC Pole - 9 Mtrs Long, 300 kg WL Nos 1 4578 4578 1060 1060

2 PSC Pole - 9 Mtrs Long, 200 kg WL Nos 23 3401 78223 1060 24380

Horizontal cross arms with clamps, HTST supports,


3 Set 1 377 377 99 99
bolts, nuts and washers for PSCC poles
Horizontal cross arms with clamps, HTST supports,
4 Set 23 377 8671 99 2277
bolts, nuts and washers for PSC poles

5 DP Structure with 9 Mtrs PSCC Poles of 300Kg WL Set 1 13184 13184 3252 3252

6 11 kV Pin Insulators with GI pins Nos 72 94 6768 0 0

7 45 kN Disc Insulators Nos 6 290 1740 0 0

8 Guy Set Complete Sets 6 742 4452 354 2124

9 Rabbit ACSR Conductor Kms 3.045 33676 102543 2608 7941

10 PG Clamps for Rabbit Conductor Nos 6 76 456 0 0

11 Spiral Earth Electrode Nos 26 207 5382 55 1430

Set of 2
12 EG Stirrups with GI wire lacing 24 370 8880 99 2376
Nos

13 Concreting materials for guy sets without cement Nos 6 158 948 0 0

Caution/Danger Board as per Drawing No.


14 Nos 8 120 960 48 384
BESCOM/GM/CP/40/Dt: 24.10.07

Anti Climbing Device (10mtrs/1 Kg GI Barbed Wire)


15 Nos 26 64 1664 25 650
Lumpsum

Total 238826 45973

16 Labour charges

a) Casual 45973

b) Regular 9195

Total Cost/Km in Rs. 293994

Note: 1) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 69
Running Single Circuit 1.1 kV 3 Phase 5 Wire Power Line on 9 Mtr Supports with Average Span of 40 Mtrs Using
3x95 + 1x16 + 1x70 Sqmm Aerial Bunched Cables (ABC) using 9mtr PSCC pole of 300kg WL for Dead Ends and
Anchor Points

SL. Material cost Labour Cost


Particulars Unit Qty
No
Rate Amt Rate Amt

1 PSCC Poles 9 Mtr long with 300 Kg WL Nos 10 4578 45780 1060 10600

2 PSC Poles 9 Mtr long with 200 Kg WL Nos 15 3401 51015 1060 15900

1.1kV Class 3 Phase Aerial Bunched Cable of


3 kms 1.015 410000 416150 20426 20732
size 3x95+1x16+1x70 Sqmm

4 Three Phase Distribution box for 6 Connections Nos 20 2065 41300 538 10760

Piercing connector suitable for 16 Sqmm - 95


5 Nos 60 228 13680 77 4620
Sqmm AB Cable - Service Connections

Piercing connector suitable for 16 Sqmm - 95


6 Nos 25 160 4000 54 1350
Sqmm AB Cable - Street Light Connections
Suspension Clamp Assembly 16 to 70 mm
7 Sets 20 190 3800 115 2300
( Excluding pole clamp & Eye Hook )

8 Pole clamp for HT/LT AB cable Sets 20 100 2000 192 3840

Eye Hook (Flat type) for fixing Clamps Sets 20 90 1800 0 0


Dead End Clamp/Anchor Clamp Assembly 25
8 to 95 Sq mm (excluding pole clamps and Eye Sets 16 200 3200 115 1840
hook)
9 Universal Hook, Bolts & nuts Nos 16 305 4880 115 1840

10 T-connector KZ3 95 Nos 8 338 2704 130 1040


Cable Straight thru' joint kits suitable for 95
11 Sets 5 310 1550 192 960
Sqmm

12 Pre-Insulated lugs-CPTAU for 95 Sqmm Nos 8 338 2704 160 1280

13 End cap for 50/70 Sqmm Nos 50 19 950 5 250

14 Guy Set Complete Sets 8 723 5784 354 2832

15 Concreting for Guy sets (without cement) Sets 8 158 1264 0 0

16 PVC Insulated wire 16/25 Sqmm Mtrs 400 23.52 9408 0 0

17 Spiral Earth Electrodes Nos 25 207 5175 55 1375

Total Cost of Materials 617144

18 Labour Charges

a) Casual 81519

b) Regular 16304

Total Cost/Km in Rs. 714967

While preparing estimates for turnkey / total turnkey projects please refere to Sl. No. …….. To general
1
guidelines vide a to …. page No. ……. To ……..
COST DATA SHEET - 68
Running Single Circuit 11kV, 3 Phase Power Line on 9 Mtr Supports with an Average Span of 30 Mtrs Using 3x95
Sqmm + 1x70 Sqmm Aerial Bunched Cables (ABC) using 9mtr PSCC pole of 300kg WL for Dead Ends and Anchor
Points

Material cost Labour Cost


SL.
Particulars Unit Qty
No
Rate Amt Rate Amt

1 PSCC Poles 9 Mtr long with 300 Kg WL Nos 10 4578 45780 1060 10600

2 PSC Poles 9 Mtr long with 200 Kg WL Nos 24 3401 81624 1060 25440

11kV Class 3 phase Aerial Bunched Cable 3x95


3 Kms 1.015 631000 640465 20426 20732
+ 70 Sqmm

Cable Straight thru' joint kits suitable for 95


4 Nos 6 5650 33900 828 4968
Sqmm
11 KV AB CableTermination Kits fo 95 to 120
6 Nos 6 2100 12600 700 4200
Sqmm
Suspension Clamp Assembly 16 to 70 mm
7 Sets 30 190 5700 115 3450
( Excluding pole clamp & Eye Hook )

Pole clamp for HT/LT AB cable Sets 30 100 3000 192 5760

8 Eye Hook (Flat type) for fixing Clamps Sets 30 90 2700 0 0

Dead End Clamp/Anchor Clamp Assembly 25


to 95 Sq mm (excluding pole clamps and Eye Sets 12 200 2400 115 1380
hook)

9 End Caps Nos 10 19 190 5 50

11kV Lightning Arrester, Metal Oxide


10 Set (3Nos) 2 2409 4818 107 214
9kV, 5kA

11 Guy Set Complete Sets 6 742 4452 354 2124

12 Concreting for Guy sets (without cement) Sets 6 158 948 0 0

13 Grounding connection for messenger wire Nos 4 122 488 26 104

15 Spiral Earth Electrodes Nos 34 207 7038 55 1870

Total Cost of Material 846103

16 Labour Charges

a) Casual 80892.4

b) Regular 16178.5

17 Total Cost/Km in Rs. 943173.9

While preparing estimates for turnkey / total turnkey projects please refere to Sl. No. …….. To general
guidelines vide a to …. page No. ……. To ……..
COST DATA SHEET - 67
Erection of 3 Phase, 11kV/433V, 100kVA BEE 3 Star Rated Single Pole Mounted Transformer
Centre on 9 Mtrs PSCC Pole 300kg WL
Sl. Material cost Labour Cost
Materials Unit Qty
No Rate Amt Rate Amt

1 9 Mtr long PSCC pole of 300kg WL No 1 4578 4578 1060 1060

2 11kV Pin Insulators with pins Nos 3 94 282 0 0

3 45kN Disc Insulator Nos 3 290 870 0 0

4 Guy Set Complete Set 1 742 742 354 354


Single pole TC set suitable for 100 kVA
5 Set 1 6129 6129 1016 1016
Transformer
11kV/433V, 100kVA, 3 Phase, 50 Cys
6 Distribution Transformer BEE-3 Star Rated with No 1 121422 121422 910 910
Oil

Earthing materials pipe type for grounding as


7 per Drawing No. BESCOM/GM/CP/15 & 34/Dt: Nos 3 1277 3831 573 1719
24.10.07.

8 Providing Concreting for 9 mtr RCC Pole 0

a) Base concreting 1:4:8, 500x650x150 mm Each 1 229 229 0 0

b) Pole concreting 1:2:4, 650x500x1700 Each 1 2566 2566 0 0

c) Coping 1:2:4 (as per actuals) Each 1 444 444 0 0

Concreting materials for Guy sets (without


9 No 1 158 158 0 0
cement )

10 GI Wire 8 SWG Kgs 5 54.67 273.35 0 0

11 Guy Wire 7/10 SWG Kgs 10 57.7 577 0 0

11kV Lightning Arester, Metal Oxide


12 Set/3 Nos 1 2070 2070 71 71
9kV, 5kA

a) LT Protection Kit No 2 1602 3204 205 410

b) LT Distribution Box for 100kVA with MCB No 1 16705 16705 455 455

c) LT Wiring (From DTC to LT Line Through


Merering Box & LT Protection Kit/LT No 1
Distribution Box) SINGLE CIRCUIT

i. Al Lead Wire - 120 Sqmm Mtrs 45 108 4860

ii. Copper lugs - 120 Sqmm Nos 12 77 924


13
iii. PG Clamps - Rabbit to 120 Sqmm Nos 4 204 816 568 568

iv. Spacers for DTC Wiring Nos 8 38 304

v. Fish Plate with necessary Clamps, bolts &


Nos 2 155 310
nuts etc complete (Galvanised)
d) LT Metering box with CTs and necessary
wiring for housing ETV Meter (Please see CDS- No 1 4918 4918 514 514
42)
e) LT Electronic Tri-Vector Meter 5A, Class-
No 1 2250 2250 631 631
0.5/1.0 accuracy

14 11kV Solid Core Type HG Fuse Unit Set/3 Nos 1 827 827 423 423

15 11kV, 200Amps, Single Break GOS Nos 1 6951 6951 636 636

Caution/Danger Board as per Drawing No.


16 No 1 120 120 48 48
BESCOM/GM/CP/40/ Dt: 24.10.07
Anti Climbing Device (12mtrs/1Kg GI Barbed
17 Kg 1 64 64 25 25
Wire) Lumpsum
18 Total Material Cost

a) With LT Distribution Box 183220

b) With LT Protection Kit 169719

19 Labour Charges for LT Distribution Box for LT Protection Kit

a) Casual 8430 8385


b) Regular 1686 1677

Total
Total Cost for Erection of a Single Pole Mounted 100kVA Transformer with
193336
LT Distribution Box in Rs
Total Cost for Erection of a Single Pole Mounted 100kVA Transformer with
179781
LT Protection KIT in Rs
COST DATA SHEET - 66
Erection of 3 Phase, 11kV/433V, 63kVA BEE 3 Star Rated Single Pole Mounted Transformer
Centre on 9 Mtrs PSCC Pole 300kg WL
Material cost Labour Cost
Sl.
Materials Unit Qty
No Rate Amt Rate Amt

1 9 Mtr long PSCC pole of 300kg WL No 1 4578 4578 1060 1060

2 11kV Pin Insulators with pins Nos 3 94 282 0 0

3 45kN Disc Insulator Nos 3 290 870 0 0

4 Guy Set Complete Set 1 742 742 354 354


Single pole TC set suitable for 63 kVA
5 Set 1 4088 4088 1016 1016
Transformer
11kV/433V, 63kVA, 3 Phase, 50 Cys
6 Distribution Transformer BEE-3 Star Rated with No 1 93726 93726 682 682
Oil
Single
Earthing materials pipe type for grounding as
Electrode
7 per Drawing No. BESCOM/GM/CP/15 & 34/ 3 1277 3831 573 1719
with
Dt: 24.10.07
accessories
8 Concreting materials for 9 mtr RCC Pole

a) Base concreting 1:4:8, 500x650x150 mm Each 1 229 229 0 0

b) Pole concreting 1:2:4, 650x500x1700 Each 1 2566 2566 0 0

c) Coping 1:2:4 (as per actuals) Each 1 444 444 0 0


Concreting materials for Guy sets (without
9 No 1 158 158 0 0
cement )
10 GI Wire 8 SWG Kgs 5 54.67 273.35 0 0
11 Guy Wire 7/10 SWG Kgs 10 57.7 577 0 0
11kV Lightning Arester, Metal Oxide
12 Set/3 Nos 1 2070 2070 71 71
9kV, 5kA

a) LT Protection Kit for 63 kVA Nos 2 1602 3204 205 410


b) LT Wiring (From DTC to LT Line Through
Merering Box & LT Protection Kit) SINGLE No 1
CIRCUIT
i. Al Lead Wire - 95 Sqmm Mtrs 40 82 3280

ii. Copper lugs - 95 Sqmm Nos 4 71 284

13 iii. PG Clamps - Rabbit to 95 Sqmm Nos 4 105 420 568 568

iv. Spacers for DTC Wiring Nos 8 38 304

v. Fish Plate with necessary Clamps,bolts & nuts


Nos 2 155 310
etc complete (Galvanised)
c) LT Metering box with CTs and necessary
No 1 5224 5224 514 514
wiring for housing ETV Meter (Please see CDS-42)
d) LT Electronic Tri-Vector Meter 5A, Class-
No 1 2250 2250 631 631
0.5/1.0 accuracy
14 11kV Solid Core Type HG Fuse Unit Set/3 Nos 1 827 827 423 423

15 11kV, 200Amps, Single Break GOS Nos 1 6951 6951 636 636

Caution/Danger Board as per Drawing No.


16 No 1 120 120 48 48
BESCOM/GM/CP/40/ Dt: 24.10.07
Anti Climbing Device (12mtrs/1Kg GI Barbed
17 Kg 1 64 64 25 25
Wire) Lumpsum

18 Total material cost 137672

19 Labour Charges
a) Casual 8157
b) Regular 1631

Total cost for Erection of a Single Pole Mounted 63kVA Transformer in Rs 147461
COST DATA SHEET - 65
Erection of 3 Phase, 11kV/433V, 25kVA BEE 3 Star Rated Single Pole Mounted Transformer Centre
on 9 Mtrs PSCC Pole 300kg WL
Sl. Material cost Labour Cost
Materials Unit Qty
No
Rate Amt Rate Amt

1 9 Mtr long PSCC pole of 300kg WL No 1 4578 4578 1060 1060

2 11kV Pin Insulators with pins Nos 3 94 282 0 0

3 45kN Disc Insulator Nos 3 290 870 0 0

4 Guy Set Complete Set 1 742 742 354 354


Single pole TC set suitable for 25 kVA
5 Set 1 4088 4088 1016 1016
Transformer
11kV/433V, 25kVA, 3 Phase, 50 Cys
5 Distribution Transformer BEE-3 Star Rated with No 1 51560 51560 682 682
Oil
Single
Earthing materials pipe type for grounding as
Electrode
7 per Drawing No. BESCOM/GM/CP/15 & 34/ 3 1277 3831 573 1719
with
Dt: 24.10.07
accessories
8 Concreting materials for 9 mtr PSCC Pole

a) Base concreting 1:4:8, 500x650x150 mm Each 1 229 229 0 0

b) Pole concreting 1:2:4, 650x500x1700 Each 1 2566 2566 0 0

c) Coping 1:2:4 (as per actuals) Each 1 444 444 0 0


Concreting materials for Guy sets (without
9 No 1 158 158 0 0
cement)
10 GI Wire 8 SWG Kgs 5 54.67 273.35 0 0

11 Guy Wire 7/10 SWG Kgs 10 57.7 577 0 0


11kV Lightning Arester, Metal Oxide
12 Set/3 Nos 1 2070 2070 71 71
9kV, 5kA

a) LT Protection Kit for 25 kVA No 1 1602 1602 205 205


b) LT Wiring (From DTC to LT Line Through
Metering Box & LT Protection Kit) SINGLE No 1
CIRCUIT
i. Al Lead Wire - 50 Sqmm Mtrs 25 45 1125

ii. Copper lugs - 50 Sqmm Nos 4 30 120

13 iii. PG Clamps - Rabbit to 50 Sqmm Nos 4 66 264 568 568

iv. Spacers for DTC Wiring Nos 8 38 304

v. Fish Plate with necessary Clamps,bolts & nuts


Nos 2 155 310
etc complete (Galvanised)
c) LT Metering box with CTs and necessary
No 1 5662 5662 514 514
wiring for housing ETV Meter (Please see CDS-42)
d) LT Electronic Tri-Vector Meter 5A, Class-
No 1 2250 2250 631 631
0.5/1.0 accuracy
14 11kV Solid Core Type HG Fuse Unit Set/3 Nos 1 827 827 423 423

15 11kV, 200Amps, Single Break GOS Nos 1 6951 6951 636 636

Caution/Danger Board as per Drawing No.


16 No 1 120 120 48 48
BESCOM/GM/CP/40/ Dt: 24.10.07
Anti Climbing Device (12mtrs/1Kg GI Barbed
17 Kg 1 64 64 25 25
Wire) Lumpsum

18 Total Material Cost 91867.2

Labour Charges

a) Casual 7952

b) Regular 1590

Total cost for erection of a single pole mounted 25kVA Transformer in Rs 101410
COST DATA SHEET - 64
Erection of 3 Phase, 11kV/433V, 250kVA BEE – 3 Star Rated Distribution Transformer Centre Using
DPTS With 9 Mtrs PSCC Pole 300Kg WL

250 KVA
Sl.No Particulars Unit Qty Material cost Labour Cost
Rate Amt Rate Amt

1 Part-A: TRANSFORMER

a) 9 Mtr PSCC DP Transformer Structure (Using 9


No 1 21849 21849 4238 2999
Mtr PSCC Poles of 300Kg WL)
b) 8 Mtr RCC DP Transformer Structure (Using 8 Will be Will be
No 1 3816 2703
Mtr PSC Poles 200kg WL) intimated intimated

2 11kV Pin Insulators Sets 3 94 282 0 0

3 45kN Disc Insulators Sets 3 290 870 0 0

4 Guy Set Complete Nos 4 742 2968 354 1416


11kV/433V, 250kVA, 3 Phase, 50 Cys
5 No 1 277240 277240 1365 1365
Distribution Transformer with oil
Single
Earthing materials pipe type for grounding as per
Electrode
6 Drawing No. BESCOM/GM/CP/15 & 34/ Dt: 3 1277 3831 573 1719
with
24.10.07
accessories
Caution/Danger Board as per Drawing No.
7 No 1 120 120 48 48
BESCOM/GM/CP/40/ Dt: 24.10.07
Anti Climbing Device (12mtrs/1Kg GI Barbed
8 Kgs 2 64 128 25 50
Wire) Lumpsum

9 Concreting for Guy sets without cement Nos 4 158 632 0 0

10 GI Wire 8 SWG Kgs 5 54.67 273 0 0


11 Guy wire 7/10 SWG Kgs 10 56.26 563 0 0

Total using 9 mtr PSCC Poles of 300Kg WL 308756 7597

Total using 8 mtr PSC Poles 200kg WL 286907 7301

12 Labour Charges

Total using 9 mtr PSCC Poles of 300Kg WL

a) Casual 7597

b) Regular 1519

ii) using 8 mtr poles

a) Casual 7301

b) Regular 1460

13 Total for Part-A

Total using 9 mtr PSCC Poles of 300Kg WL 317872


Will be
Total using 8 mtr PSC Poles 200kg WL
intimated
Part-B:
11kV Lightning Arester, Metal Oxide
14 Set of 3 Nos 1 2070 2070 71 71
9kV, 5kA
15 Labour Charges

a) Casual 71

b) Regular 14

16 Total for Part-B 2155

Part-C: SWITCH GEAR

a) LT Distribution box for 250kVA with MCCB No 1 16705 16705 455 455

b) LT Wiring (From DTC to LT Line via Metering


No 1
Box & LT Protection Kit) SINGLE CIRCUIT

i. Al Lead Wire - 240 Sqmm Mtrs 45 199 8955

ii. Copper lugs - 240 Sqmm Nos 12 184 2208

17 iii. PG Clamps - Rabbit to 240 Sqmm Nos 4 307 1228 644 644

iv. Spacers for DTC Wiring Nos 8 38 304

v. Fish Plate with necessary Clamps,bolts & nuts


Nos 2 155 310
etc complete (Galvanised)

c) LT Metering box with CTs and necessary wiring


No 1 5080 5080 514 514
for housing ETV Meter (Please see CDS-42)

d) LT Electronic Tri-Vector Meter 5A, Class-


Nos. 1 2250 2250 631 631
0.5/1.0 accuracy

18 11kV Solid Core Type HG Fuse Unit Set/ 3 nos 1 827 827 423 423

19 11kV, 200Amps, Single Break GOS No 1 6951 6951 636 636

Total Cost (Material) 44818

20 Labour Charges

a) Casual 3303

b) Regular 661

21 Total for Part-C 48782

22 Total (A+B+C)

Total using 9 mtr PSCC Poles of 300Kg WL 368809

Labour Charges:

a) Casual 10971

b) Regular 2194
Will be
Total using 8 mtr PSC Poles 200kg WL
intimated
Labour Charges:

a) Casual 10675

b) Regular 2135

Note: Provision for actual quantity of additional materials viz 45kN Disc Insulator, 11 kV Pin Insulators ACSR/AAA Conductor,
Transparent Alkathine Tube, PG Clamps and Terminal Connectors etc. Whenever required may be made in the estimate
separately for
While preparing estimates for turnkey / total tunkey projects please refer to Sl. No. ......... of General Guidelines vide a
1
to .... in Page No. ...........
COST DATA SHEET -63
Erection of 3 Phase, 11kV/433V, 100kVA BEE – 3 Star Rated Distribution Transformer Centre Using
DPTS With 9 Mtrs PSCC Pole 300Kg WL

100 KVA

Sl No Particulars Unit Qty Material cost Labour Cost

Rate Amt Rate Amt


1 Part-A: TRANSFORMER

a) 9 Mtr PSCC DP Transformer Structure (Using


No 1 21849 21849 4238 4238
9 Mtr PSCC Poles of 300Kg WL)
b) 8 Mtr RCC DP Transformer Structure (Using Will be Will be
No 1 3816 3816
8 Mtr PSC Poles 200kg WL) intimated intimated

2 11kV Pin Insulators Sets 3 94 282 0 0

3 45kN Disc Insulators Sets 3 290 870 0 0

4 Guy Set Complete Nos 4 742 2968 354 1416


11kV/433V, 100kVA, 3 Phase 50 Cys
5 Distribution Transformer BEE - 3 Star Rated No 1 121422 121422 910 910
with Oil
Single
Earthing materials pipe type for grounding as
Electrode
6 per Drawing No. BESCOM/GM/CP/15 & 34/ 3 1277 3831 573 1719
with
Dt: 24.10.07
accessories

Caution/Danger Board as per Drawing No.


7 No 1 120 120 48 48
BESCOM/GM/CP/40/ Dt: 24.10.07
Anti Climbing Device (12mtrs/1Kg GI Barbed
8 Kgs 2 64 128 25 50
Wire) Lumpsum
9 Concreting for Guy sets without cement Nos 4 158 632 0 0

10 GI Wire 8 SWG Kgs 5 54.67 273 0 0


11 Guy wire 7/10 SWG Kgs 10 56.26 563 0 0

Total using 9 mtr PSCC Poles of 300Kg WL 152938 8381


Will be
Total using 8 mtr PSC Poles 200kg WL 7959
intimated
12 Labour Charges

Total using 9 mtr PSCC Poles of 300Kg WL

a) Casual 8381

b) Regular 1676

Total using 8 mtr PSC Poles 200kg WL

a) Casual 7959

b) Regular 1592

13 Total for Part-A

Total using 9 mtr PSCC Poles of 300Kg WL 162995


Will be
Total using 8 mtr PSC Poles 200kg WL
intimated
Part-B:
11kV Lightning Arester, Metal Oxide
14 Set of 3 Nos 1 2070 2070 71 71
9kV, 5kA
15 Labour Charges

a) Casual 71
b) Regular 14

16 Total for Part-B 2155

Part-C: SWITCH GEAR

a) LT Protection Kit Nos 2 1602 3204 205 410

b) LT Distribution box for 100 kVA with MCB No 1 16705 16705 455 455

c) LT Wiring (From DTC to LT Line Through


Merering Box & LT Protection Kit/LT No 1
Distribution Box) SINGLE CIRCUIT

i. Al Lead Wire - 120 Sqmm Mtrs 45 108 4860

ii. Copper lugs - 120 Sqmm Nos 12 77 924


17

iii. PG Clamps - Rabbit to 120 Sqmm Nos 4 204 816 568 568

iv. Spacers for DTC Wiring Nos 8 38 304

v. Fish Plate with necessary Clamps,bolts &


Nos 2 155 310
nuts etc complete (Galvanised)
d) LT Metering box with CTs and necessary
wiring for housing ETV Meter (Please see CDS- No 1 4918 4918 514 514
42)
e) LT Electronic Tri-Vector Meter 5A, Class-
Nos 1 2250 2250 631 631
0.5/1.0 accuracy

18 11kV Solid Core Type HG Fuse Unit Set/3 Nos 1 827 827 423 423

19 11kV, 200Amps, Single Break GOS No 1 6951 6951 636 636

With LT Protection
With Distribution Box
kit

Total Cost (Material) 25364 38865

20 Labour Charges

a) Casual 3182 3227

b) Regular 636 645

21 Total for Part-C 29182 42737

22 Total (A+B+C)

Total using 9 mtr PSCC Poles of 300Kg WL 194333 207888

Labour Charges:

a) Casual 11634 11679

b) Regular 2327 2336


Will be Will be
Total using 8 mtr PSC Poles 200kg WL
intimated intimated
Labour Charges:

a) Casual 11212 11257

b) Regular 2242 2251

Note: Provision for actual quantity of additional materials viz 45kN Disc Insulator, 11kV Pin Insulators ACSR/AAA Conductor,
Transparent Alkathine Tube, PG Clamps and Terminal Connectors etc. Whenever required may be made in the estimate
separately for
COST DATA SHEET -62
Erection of 3 Phase, 11kV/433V, 63kVA BEE – 3 Star Rated Distribution Transformer Centre Using
DPTS With 9 Mtrs PSCC Pole 300Kg WL

63 KVA
Sl
Particulars Unit Qty Material Cost Labour Cost
No
Rate Amt Rate Amt

1 Part-A: TRANSFORMER

a) 9 Mtr PSCC DP Transformer Structure (Using 9


No 1 19806 19806 4115 4115
Mtr PSCC Poles of 300Kg WL)
b) 8 Mtr RCC DP Transformer Structure (Using 8 Will be Will be
No 1 3560 3560
Mtr PSC Poles 200kg WL) intimated intimated

2 11kV Pin Insulators Sets 3 94 282 0 0

3 45kN Disc Insulators Sets 3 290 870 0 0

4 Guy Set Complete Nos 4 742 2968 354 1416

11kV/433V, 63kVA, 3 Phase, 50 Cys Distribution


5 No 1 93726 93726 682 682
Transformer BEE - 3 Star Rated with Oil

Single
Earthing materials pipe type for grounding as per
Electrode
6 Drawing No. BESCOM/GM/CP/15 & 34/ Dt: 3 1277 3831 573 1719
with
24.10.07
accessories
Caution/Danger Board as per Drawing No.
7 No 1 120 120 48 48
BESCOM/GM/CP/40/ Dt: 24.10.07
Anti Climbing Device (12mtrs/1Kg GI Barbed
8 Kgs 2 64 128 25 50
Wire) Lumpsum

9 Concreting for Guy sets without cement Nos 4 158 632 0 0

10 GI Wire 8 SWG Kgs 5 54.67 273 0 0


11 Guy wire 7/10 SWG Kgs 10 56.26 563 0 0

Total using 9 mtr PSCC Poles of 300Kg WL 123199 8030


Will be
Total using 8 mtr PSC Poles 200kg WL 7475
intimated
12 Labour Charges

Total using 9 mtr PSCC Poles of 300Kg WL

a) Casual 8030

b) Regular 1606

Total using 8 mtr PSC Poles 200kg WL

a) Casual 7475

b) Regular 1495

13 Total for Part-A

Total using 9 mtr PSCC Poles of 300Kg WL 132835


Will be
Total using 8 mtr PSC Poles 200kg WL
intimated
Part-B:

11kV Lightning Arester, Metal Oxide


14 Set of 3 Nos 1 2070 2070 71 71
9kV, 5kA
15 Labour Charges
a) Casual 71

b) Regular 14

16 Total for Part-B 2155

Part-C: SWITCH GEAR

a) LT Protection Kit for 63 kVA Nos 2 1602 3204 205 410

b) LT Wiring (From DTC to LT Line Through


Metering Box & LT Protection Kit) SINGLE No 1
CIRCUIT

i. Al Lead Wire - 95 Sqmm Mtrs 40 82 3280

ii. Copper Lugs - 95 Sqmm Nos 4 71 284

17 iii. PG Clamps - Rabbit to 95 Sqmm Nos 4 105 420 568 568

iv. Spacers for DTC Wiring Nos 8 38 304

v. Fish Plate with necessary Clamps,bolts & nuts


Nos 2 155 310
etc complete (Galvanised)

c) LT Metering box with CTs and necessary wiring


No 1 5224 5224 514 514
for housing ETV Meter (Please see CDS-42)

d) LT Electronic Tri-Vector Meter 5A, Class-


No 1 2250 2250 631 631
0.5/1.0 accuracy

18 11kV Solid Core Type HG Fuse Unit Set/ 3 nos 1 827 827 423 423

19 11kV, 200Amps, Single Break GOS No 1 6951 6951 636 636

Total Cost (Material) for Part-C 23054

20 Labour Charges

a) Casual 3182

b) Regular 636

21 Total for Part-C 26872

22 Total (A+B+C)

Total using 9 mtr PSCC Poles of 300Kg WL 161863

Labour Charges:

a) Casual 11283

b) Regular 2257
Will be
Total using 8 mtr PSC Poles 200kg WL
intimated
Labour Charges:

a) Casual 10728

b) Regular 2146

Note: Provision for actual quantity of additional materials viz 45kN Disc Insulator, 11kV Pin Insulators ACSR/AAA Conductor,
Transparent Alkathine Tube, PG Clamps and Terminal Connectors etc. Whenever required may be made in the estimate
separately for
COST DATA SHEET - 61
Erection of 3 Phase, 11kV/433V, 25kVA BEE – 3 Star Rated Distribution Transformer Centre Using
DPTS With 9 Mtrs PSCC Pole 300Kg WL

25 KVA
Sl
Particulars Unit Qty Material Cost Labour Cost
No
Rate Amt Rate Amt

1 Part-A: TRANSFORMER

a) 9 Mtr PSCC DP Transformer Structure (Using 9


No 1 19806 19806 4115 4115
Mtr PSCC Poles of 300Kg WL)
b) 8 Mtr RCC DP Transformer Structure (Using 8 will be will be
No 1 3560 3560
Mtr PSC Poles 200kg WL) intimated intimated

2 11kV Pin Insulators Sets 3 94 282 0 0

3 45kN Disc Insulators Sets 3 290 870 0 0

4 Guy Set Complete Nos 4 742 2968 354 1416


11kV/433V, 25KVA, 3 Phase, 50 Cys
5 Distribution Transformer BEE-3 Star Rated with No 1 51560 51560 682 682
Oil
Single
Earthing materials pipe type for grounding as per
Electrode
6 Drawing No. BESCOM/GM/CP/15 & 34/ Dt: 3 1277 3831 573 1719
with
24.10.07
accessories
Caution/Danger Board as per Drawing No.
7 No 1 120 120 48 48
BESCOM/GM/CP/40/ Dt: 24.10.07
Anti Climbing Device (12mtrs/1Kg GI Barbed
8 Kgs 2 64 128 25 50
Wire) Lumpsum

9 Concreting for Guy sets without cement Nos 4 158 632 0 0

10 GI Wire 8 SWG Kgs 5 54.67 273.35 0 0


11 Guy wire 7/10 SWG Kgs 10 56.26 563 0 0

Total using 9 mtr PSCC Poles of 300Kg WL 81033 8030

will be
Total using 8 mtr PSC Poles 200kg WL 7475
intimated

12 Labour Charges

Total using 9 mtr PSCC Poles of 300Kg WL

a) Casual 8030

b) Regular 1606

Total using 8 mtr PSC Poles 200kg WL

a) Casual 7475

b) Regular 1495

13 Total for Part-A

Total using 9 mtr PSCC Poles of 300Kg WL 90669


will be
Total using 8 mtr PSC Poles 200kg WL
intimated
Part-B:
11kV Lightning Arester, Metal oxide,
14 Set of 3 Nos 1 2070 2070 71 71
9kV, 5kA
15 Labour Charges

a) Casual 71
b) Regular 14

16 Total for Part-B 2155

Part-C: SWITCH GEAR

a) LT Protection Kit for 25 kVA No 1 1602 1602 205 205

b) LT Wiring (From DTC to LT Line Through


Metering Box & LT Protection Kit) SINGLE No 1
CIRCUIT

i. Al Lead Wire - 50 Sqmm Mtrs 25 45 1125

ii. Copper Lugs - 50 Sqmm Nos 4 30 120

17 iii. PG Clamps - Rabbit to 50 Sqmm Nos 4 66 264 568 568

iv. Spacers for DTC Wiring Nos 8 38 304

v. Fish Plate with necessary Clamps,bolts & nuts


Nos 2 155 310
etc complete (Galvanised)

c) LT Metering box with CTs and necessary wiring


No 1 5662 5662 514 514
for housing ETV Meter (Please see CDS-42)
d) LT Electronic Tri-Vector Meter 5A, Class-
No 1 2250 2250 631 631
0.5/1.0 accuracy
18 11kV Solid Core Type HG Fuse Unit Set/3 Nos 1 827 827 423 423

19 11kV, 200Amps, Single Break GOS No 1 6951 6951 636 636

Total Cost (Material) for Part-C 19415

20 Labour Charges

a) Casual 2977

b) Regular 595

21 Total for Part-C 22987

22 Total (A+B+C)

Total using 9 mtr PSCC Poles of 300Kg WL 115812

Labour Charges:

a) Casual 11078

b) Regular 2216

will be
Total using 8 mtr PSC Poles 200kg WL
intimated

Labour Charges:

a) Casual 10523

b) Regular 2105

Note: Provision for actual quantity of additional materials viz 45kN Disc Insulator, 11kV Pin Insulators ACSR/AAA Conductor,
Transparent Alkathine Tube, PG Clamps and Terminal Connectors etc. Whenever required may be made in the estimate
separately for
Schedule of Rate for Standard Stock Materials Common
SR 2016-17 (11kV System)
Common SR Common SR
2014-15 2016-17
Sl Item Material in Rs FORD in Rs FORD
Name of the Material UoM
No No Code Rates inclusive Rates inclusive
of duties of duties
taxes & F&I taxes & F&I

1 Line Supports (POLES)


1 1.01 RCC Pole - 9 Mtr Long, 145 Kg WL 200105 No 5941 5941

2 1.02 RCC Pole - 9 Mtr Long, 150 Kg WL Sq Section 200106 No 7210 7210

3 1.03 RCC Pole - 8 Mtr Long, 115 Kg WL 200103 No 4324 4351


4 1.04 PCC Pole - 8 Mtr Long, 140 Kg WL 200003 No 2297 2495
5 1.05 PSCC Pole - 8 Mtr Long, 200 Kg WL 200004 No 2814 2942
6 1.06 PSCC Pole - 9 Mtr Long, 200 Kg WL 200006 No 3278 3401

PSCC Pole - 9 Mtr Long, 160 Kg WL in Transverse


7 1.07 200007 No 3558 3558
Direction & 136 Kg WL in Longitudinal Direction

Pre - Stressed Tubular Spun Pole 11 Mtr Long -


8 1.08 200120 No 15800 15800
500Kg WL
RCC Pole - 9.5 Mtr Long, 350 Kg WL for 33kV
9 1.09 200107 No 7675 7675
Lines
11Mtrs Long PSC pole of working Load 365 Kg for
10 1.10 200010 No 7924 7924
intermediate poles only

11 1.11 9 Mtr PSCC Pole with working load of 300Kg 4578 4578

12 1.12 Guy less poles New Item Will be intimated

Strut pole made of released MS Rail pole or


13 1.13 Tubular pole along with clamp fish plate, bolts & 200514 No 2310 2008
nuts
11Mtrs Long pole made of I Beam (MS) section
14 1.14 200621 No 18009 15657
size 200x100mm 25.9 Kg/mtr
11Mtrs Long pole made of I Beam (MS) section
15 1.15 200610 No 12321 10712
size 175x85mm 19.5 Kg/mtr
2 Cross Arms (MS & GI)
16 2.01 11kV Horizontal X Arms - Mild Steel (MS) 279020 No 281 238

17 2.02 11kV Horizontal X Arms - Galvanised Iron (GI) 280020 No 359 315

18 2.03 11kV Special 3 Pin X Arm - MS 279013 No 664 561


19 2.04 11kV Special 3 Pin X Arm - GI 280013 No 848 745
20 2.05 LT 4 Pin X Arms - MS 279014 No 218 185
21 2.06 LT 4 Pin X Arms - GI 280014 No 278 245
22 2.07 LT 2 Pin X Arms - MS 279012 No 100 84
23 2.08 LT 2 Pin X Arms - GI 280012 No 127 112
2 Pin Cross Arm with pole clamp, bolt & nuts &
24 2.09 - No 200 162
washers for RCC Pole - MS
2 Pin Cross Arm with pole clamp, bolt & nuts &
25 2.10 248 219
washers for RCC Pole - GI
2 Pin Cross Arm with pole clamp, bolt & nuts &
26 2.11 - No 194 157
washers for PSC Pole - MS
2 Pin Cross Arm with pole clamp, bolt & nuts &
27 2.12 240 212
washers for PSC Pole - GI
4 Pin Cross Arm with pole clamp, bolt & nuts &
28 2.13 - No 318 263
washers for RCC Pole - MS
4 Pin Cross Arm with pole clamp, bolt & nuts &
29 2.14 399 352
washers for RCC Pole - GI
4 Pin Cross Arm with pole clamp, bolt & nuts &
30 2.15 - No 312 258
washers for PSC Pole - MS
4 Pin Cross Arm with pole clamp, bolt & nuts &
31 2.16 391 345
washers for PSC Pole - GI
11 kV Horizontal Cross Arm with single top
32 2.17 support, clamp, Bolt & Nuts with washers for RCC - No 449 382
Poles - MS
11 kV Horizontal Cross Arm with single top
33 2.18 support, clamp, Bolt & Nuts with washers for RCC 567 505
Poles - GI
11 kV Horizontal Cross Arm with single top
34 2.19 support, clamp, Bolt & Nuts with washers for - No 443 377
PSCC Poles - MS
11 kV Horizontal Cross Arm with single top
35 2.20 support, clamp, Bolt & Nuts with washers for 559 498
PSCC Poles - GI
Special 3 Pin Cross Arm, clamp and Bolt & Nuts
36 2.21 - No 764 639
for RCC Poles - MS
Special 3 Pin Cross Arm, clamp and Bolt & Nuts
37 2.22 969 852
for RCC Poles - GI
38 2.23 LT ST Support 50x6mm Flat - MS 279091 No 50 43
39 2.24 LT ST Support 50x6mm Flat - GI 280091 No 64 56
40 2.25 HT ST Support 50x6mm Flat - MS 279092 No 68 59
41 2.26 HT ST Support 50x6mm Flat - GI 280092 No 87 76
42 2.27 Brace for LT 4pin X arm (600mm long) - MS 279082 No 215 187
43 2.28 Brace for LT 4pin X arm (600mm long) - GI 280082 No 269 234
Brace for 11 kV special 3pin X arm (900mm long) -
44 2.29 279083 No 299 260
MS
Brace for 11 kV special 3pin X arm (900mm long) -
45 2.30 280083 No 374 325
GI
46 2.31 LT Cross arms for vertical Configuration - MS 279017 No 720 626
47 2.32 LT Cross arms for vertical Configuration - GI 280017 No 901 784
48 2.33 EG Stirrups (MS) with GI wire lacing 279130 No 212 185
49 2.34 Spiral Earth Electrode 281683 No 238 207
3 SMC Line Materials
11KV Cross arm with HT top support (glass
50 3.01 279090 No 750 750
reinforced hot pressed SMC compound)
4 Anticlimbing Device
51 4.01 Spike type GI About 3.0 Kg in weight 278910 No 151 131
52 4.02 GI Barbed wire (12mtrs/Kg) 278911 Each 73 64
5 Clamps (MS & GI)
53 5.01 RCC Pole clamp - MS 279523 No 60 50
54 5.02 RCC Pole clamp - GI 280523 No 76 67
55 5.03 PCC Pole clamp - MS 279503 No 50 42
56 5.04 PCC Pole clamp - GI 280503 No 63 55
57 5.05 PSCC Pole clamp - MS 279510 No 54 45
58 5.06 PSCC Pole clamp - GI 280510 No 68 60
59 5.07 PCC Pole clamp type A for LT X arm - MS 279502 No 53 44
60 5.08 PCC Pole clamp type A for LT X arm - GI 280502 No 66 58
PCC Pole clamp type A for X arm upto 1M from
61 5.09 279522 No 53 44
pole top - MS
PCC Pole clamp type A for X arm upto 1M from
62 5.10 280522 No 66 58
pole top - GI
Clamps for fixing MV Lamp control box, fuse
63 5.11 279550 No 61 53
box/St light fixture on rail pole - MS
64 5.12 Guy clamp - MS 279650 No 59 50
65 5.13 Guy clamp - GI 280650 No 75 66
66 5.14 Turn buckle (GI) 279146 No 183 159

67 5.15 Anchor Rod using 12mm rounds/Guy Rod - MS 279140 No 191 162

68 5.16 Anchor Rod using 12mm rounds/Guy Rod - GI 280140 No 244 215

69 5.17 RCC pole type C clamp for GOS Operating Handle 279524 No 61 53

70 5.18 MS Fish Plate 279800 No 59 51


71 5.19 GI Fish Plate 280800 No 67 58
Strain Clamps, 3 Bolt type for 70/90 kN Disc
72 5.20 285076 No 546 468
Insulator
6 Insulators
73 6.01 11kV Ceramic Pin Insulator (Shell only) 283005 No 49 47

74 6.02 11kV GI Pin for 11kV Ceramic Shell Insulators 283055 No 54 47

75 6.03 1.1kV Ceramic Pin Insulator (Shell only) 283003 No 15 15

76 6.04 1.1kV GI Pin FOR 11kV Cermaic shell Insulator 283053 No 26 23

11kV, 5KN Composite/Polymeric Pin


77 6.05 283007 No 169 165
Insulator(20mm dia FP Rod)
11kV, 5KN Composite/Polymeric Pin
78 6.06 New Item 195
Insulator(24mm dia FP Rod)
79 6.07 No.8 Strain Insulator 283158 No 14 14
80 6.08 No.15 Strain Insulator 283166 No 34 33
81 6.09 DISC Insulator 45kN 283040 No 300 290
82 6.10 DISC Insulator 70kN, Ball & Socket type 283017 No 506 490
83 6.11 DISC Insulator 90kN, Ball & Socket type 283018 No 506 490
84 6.12 DISC Insulator 120kN, Ball & Socket type 283021 No 506 490
85 6.13 11kV Solid Core Insulator 283315 No 157 152
86 6.14 11kV Post Insulator 283101 No 371 359
Silcon Rubber Composite Insulator/11kV 45kN
87 6.15 283320 No 170 170
Polymeric Insulator
88 6.16 11kV, 70kN Composite/Polymeric Insulator 283045 No 287 287
7 Accessories for composite insulator
89 7.01 Cross Arm Strap (MS) 279030 No 80 69
90 7.02 Strain Clamp up to Rabbit ACSR 285058 No 190 163
91 7.03 Strain Clamp for Coyote ACSR 285066 No 411 353
8 Conductor

92 8.01 Weasel ACSR 284105 Km 21900 20100

93 8.02 Rabbit ACSR 284108 Km 36810 33676


94 8.03 Coyote ACSR 284116 Km 93860 92708
95 8.04 Lynx ACSR 284120 Km 139000 137290
9 Guy Wire & GI Wire
96 9.01 7/10 SWG Guy Wire 281110 MT 64630 56267
97 9.02 8 SWG GI Wire 281008 MT 62800 54674
98 9.03 10 SWG GI Wire 281010 MT 66256 57683
99 9.04 GI Barbed Wire 12 SWG 281205 MT 77972 67882
10 PG Clamps
100 10.01 PG clamps for Lynx ACSR 285518 No 304 261
101 10.02 Coyote to Coyote 285515 No 276 267
102 10.03 Rabbit to Rabbit 285508 No 89 76
103 10.04 Weasel to Rabbit 285549 No 77 66
104 10.05 Weasel to Weasel 285509 No 60 52
105 10.06 Squirrel to Weasel 285548 No 56 48
11 PG Clamps Rabbit to Insulated Wire
106 11.01 95 Sqmm 285555 No 122 105
107 11.02 120 Sqmm 285557 No 238 204
108 11.03 150 Sqmm 285559 No 280 241
109 11.04 185 Sqmm 285562 No 308 264
110 11.05 240 Sqmm 285565 No 357 307
T - Clamps for Rabbit conductor with hot dipped
111 11.06 285600 Set 276 237
galvanized bolts, Nuts and Washers
T - Clamps for Coyote conductor with hot dipped
112 11.07 285605 Set 366 314
galvanized bolts, Nuts and Washers
T - Clamps for Lynx to Lynx with hot dipped
113 11.08 285610 Set 383 328
galvanized bolts, Nuts and Washers
114 11.09 Single Tension Clamp Suitable for Rabbit 285068 No 567 487
115 11.10 Single Tension Clamp Suitable for Coyote 285079 No 799 685
116 11.11 Pad Clamps for Rabbit ACSR 285723 No 439 376
117 11.12 Pad Clamps for Lynx ACSR 285726 No 606 520
118 11.13 Pad Clamps for Coyote ACSR 285724 No 544 467
C - Type wedge connector + 2 hole padle for
119 11.14 285661 No 412 354
Rabbit ACSR
C - Type wedge connector + 2 hole padle for
120 11.15 285662 No 1712 1468
Coyote ACSR
C - Type wedge connector + 4 hole padle for
121 11.16 285663 No 1966 1686
Coyote ACSR
C - Type wedge connector + 2 hole padle for Lynx
122 11.17 285664 No 2600 2230
ACSR
C - Type wedge connector + 4 hole padle for Lynx
123 11.18 285665 No 2853 2447
ACSR
12 C - Type wedge connector
124 12.01 Rabbit to Rabbit ACSR 285670 No 142 122
125 12.02 Rabbit to Coyote ACSR 285671 No 740 635
126 12.03 Rabbit to Lynx ACSR 285673 No 740 635
127 12.04 Coyote to Coyote ACSR 285676 No 740 635
128 12.05 Rabbit to 240 Sqmm Lead Wire 285694 No 740 635
129 12.06 Coyote to 240 Sqmm Lead Wire 285695 No 740 635
130 12.07 Coyote to Lynx ACSR 285678 No 1305 1120
131 12.08 Lynx to Lynx ACSR 285680 No 1305 1120
C wedge connector for connecting main wire of
132 12.09 size 2.5/4/6/10 Sqmm from OH Squirrel/Weasel 285691 No 78 67
line to AFB/Cutouts
C wedge connector for connecting main wire of
133 12.10 size 16/25 Sqmm from OH Rabbit line to 285692 No 99 86
AFB/Cutouts
Distribution Transformers - 3 Phase,
13
11kV/433V - Stacked Core with Oil
134 A. OPEN BUSHING TYPE
135 13.01 15kVA, Copper Winding 321301 No 53003 49980
136 13.02 25kVA, Aluminum Wdg (Conventional) 321304 No 58794 56480
137 13.03 25kVA, Aluminum Wdg, BEE 3 Star Rated 321433 No 64455 51560
138 13.04 25kVA, Aluminum Wdg, BEE 4 Star Rated 54969 54969
139 13.05 63kVA, Aluminum Wdg 321306 No 84780 81440
140 13.06 63kVA, Aluminum Wdg, BEE 3 Star Rated 321434 No 109635 93726
141 13.07 63kVA, Aluminum Wdg, BEE 4 Star Rated 94757 94757
142 13.08 100kVA, Aluminum Wdg 321310 No 105730 101570
143 13.09 100kVA, Aluminium Wdg, BEE 3 Star Rated 321435 No 146408 121422
144 13.10 100kVA, Aluminium Wdg, BEE 4 Star Rated 125856 125856
145 13.11 250kVA, Aluminum Wdg 321325 No 237696 228340
146 13.12 250kVA, BEE 3 Star Rated/Energy Efficient 321436 No 292467 277240
147 13.13 500kVA, Aluminum Wdg 321350 No 376532 361707

148 13.14 500kVA, BEE 3 star rated No New Item Will be intimated
Special Design Transformer 354.2kVA for
149 13.15 Niranthara Jyothi Works (11KV AUTO 321400 No 171030 Deleted
Transformer)
B. CABLE ENTRY TYPE
150 13.16 25kVA, Aluminum Wdg, BEE 3 Star Rated 321441 No 71455 78455
151 13.17 25kVA, Aluminum Wdg, BEE 4 Star Rated 61969
152 13.18 63kVA, Aluminum Wdg, BEE 3 Star Rated 321442 No 117635 125635
153 13.19 63kVA, Aluminum Wdg, BEE 4 Star Rated 102757
154 13.20 100kVA, Aluminium Wdg, BEE 3 Star Rated 321443 No 156408 166408
155 13.21 100kVA, Aluminium Wdg, BEE 4 Star Rated 135856
156 13.22 250kVA, Aluminum Wdg 321444 No 249696 236700
157 13.23 500kVA, Aluminum Wdg 321445 No 391532 371150

Distribution Transformer - 3 Phase,


14
11kV/433V - Amorphous Core with Oil

A. OPEN BUSHING TYPE


158 14.01 25kVA, BEE 3 Star Rated 321376 No 62536
159 14.02 25kVA, BEE 5 Star Rated
160 14.03 63kVA, BEE 3 Star Rated 321377 No 105071
161 14.04 63kVA, BEE 5 Star Rated
162 14.05 100kVA, BEE 3 Star Rated 321380 No 136410
163 14.06 100kVA, BEE 5 Star Rated
164 14.07 200kVA, BEE 3 Star Rated 321381 No 251888
Will be Intimated
165 14.08 500kVA, BEE 3 Star Rated 321382 No 751584
B. CABLE ENTRY TYPE
166 14.09 25kVA, BEE 3 Star Rated 321390 No 69536
167 14.10 63kVA, BEE 3 Star Rated 321391 No 113071
168 14.11 100kVA, BEE 3 Star Rated 321392 No 146410
169 14.12 200kVA, BEE 3 Star Rated 321393 No 263888
170 14.13 500kVA, BEE 3 Star Rated 321394 No 766584
Distribution Transformer Self
15
Protected 11kV/433V, 3 Phase
171 15.01 100 kVA 321365 No 121059
Will be Intimated
172 15.02 250 kVA 321370 No 241188
16 DTs - Single Phase, 11kV/250V
173 16.01 15kVA, Copper Wound with MCCB 321302 No 62890
15kVA, Amorphous Core Copper Winding with
174 16.02 321303 No 72770 Will be Intimated
MCCB
175 16.03 10kVA, Copper winding with MCCB 321300 No 44517
11kV/433V, 3 Phase, Dry Type
17
Transformers
176 17.01 25KVA 321483 No 221400 215780
177 17.02 63KVA 321484 No 274420 267460
178 17.03 100KVA 321485 No 360150 351000
179 17.04 250KVA 321486 No 614200 598620
180 17.05 500KVA 321487 No 891540 86890
18 Transformer Oil
181 18.01 EHV Grade Transformer oil - New 601400 kLtr 77820 59004
182 18.02 Reclaimed oil 601410 kLtr 42801 32452
183 18.03 Contaminated oil 601420 kLtr 28015 21241
19 LT Protection
184 19.01 LT Protection kit 301107 No 1679 1602
20 LT Distribution Box
LT Distribution Box for 100/250 kVA DTC with
185 20.01 301230 No 16705 16705
MCCB's (Sheet Metal)
LT Distribution Box for 100/250 kVA DTC with
186 20.02 301060 No 24715 24715
MCCB's (SMC)
21 LT Wiring kit for LT protection kit
187 21.01 For 25 kVA DTC Single Circuit 301151 Set Deleted Deleted
188 21.02 For 63 kVA DTC Single Circuit 301207 Set Deleted Deleted
189 21.03 For 63 kVA DTC Double Circuit 301152 Set Deleted Deleted

22 LT Wiring kit through Distribution Box


190 22.01 For 100 kVA DTC Single Circuit 301163 Set Deleted Deleted
191 22.02 For 100 kVA DTC Double Circuit 301153 Set Deleted Deleted
192 22.03 For 250 kVA DTC Single Circuit 301164 Set Deleted Deleted
193 22.04 For 250KVA DTC Double Circuit 301154 Set Deleted Deleted
LT Wiring kit for 63kVA Transformers (MESCOM
194 22.05 301155 Set Deleted Deleted
Specification)
LT Wiring kit for 25kVA Transformers (MESCOM
195 22.06 301156 Set Deleted Deleted
Specification)
23 Lightning Aresters
196 23.01 LA 9kV, 5kA, Metal Oxide 303200 No 761 690
197 23.02 LA 9kV, 5kA, Polymeric Type 303205 No 1164 1147
24 HG Fuse Unit
11kV Class, HG Fuse Unit with Solid Core Set/3
198 24.01 302122 871 827
Insulators No
25 Double Pole TC Sets
199 25.01 For 25/63kVA Transformer - MS 279110 Set 8500 7389
200 25.02 For 25/63kVA Transformer - GI 280110 Set 10780 9386
201 25.03 For 25/63kVA Star Rated Transformer - MS 279111 Set 12250 10650
202 25.04 For 25/63kVA Star Rated Transformer - GI 280111 Set 15545 13533
203 25.05 For 100/300kVA Transformer - MS 279120 Set 14600 12693
204 25.06 For 100/300kVA Transformer - GI 280120 Set 18562 16160

Single Pole Mounted Transformer Kit


26
for 250kVA on 11 Mtr Spun Poles
Single H Frame with Transformer Seating and
205 26.01 Seating angle support X arm for 11 mtr Spun Pole 279127 Set 19534 16983
for 25kVA (OH Line) - MS
Single H Frame with Transformer Seating and
206 26.02 Seating angle support X arm for 11 mtr Spun Pole 280117 Set 24799 21590
for 25kVA (OH Line) - GI
Three H Frame with Transformer Seating and
207 26.03 Seating angle support X arm for 11 mtr Spun Pole 279128 Set 26496 23035
for 25kVA (UG Cable) - MS
Three H Frame with Transformer Seating and
208 26.04 Seating angle support X arm for 11 mtr Spun Pole 280128 Set 33669 29312
for 25kVA (UG Cable) - GI

Single H Frame without Transformer Seating and


209 26.05 Seating angle support X arm for 11 mtr Spun Pole 279129 Set 10106 8786
for 63/100/250/500kVA (OH Line) - MS

Single H Frame without Transformer Seating and


210 26.06 Seating angle support X arm for 11 mtr Spun Pole 280129 Set 12809 11151
for 63/100/250/500kVA (OH Line) - GI

Three H Frame without Transformer Seating and


211 26.07 Seating angle support X arm for 11 mtr Spun Pole 279131 Set 16204 14087
for 63/100/250/500kVA (UG Cable) - MS

Three H Frame without Transformer Seating and


212 26.08 Seating angle support X arm for 11 mtr Spun Pole 280131 Set 20594 17929
for 63/100/250/500kVA (UG Cable) - GI

27 SPMT Materials
Single Pole Mounted Transformer kit for 25/63
213 27.01 279115 Set 4703 4088
kVA on 9 mtr RCC Poles (Square Section) - MS

Single Pole Mounted Transformer kit for 25/63


214 27.02 280115 Set 5967 5195
kVA on 9 mtr RCC Poles (Square Section) - GI

Single Pole Mounted Transformer kit for 100 kVA


215 27.03 279125 Set 7050 6129
on 9 mtr RCC Poles - MS
Single Pole Mounted Transformer kit for 100 kVA
216 27.04 280125 Set 8954 7795
on 9 mtr RCC Poles - GI
Single Pole Mounted Transformer kit for 25 kVA
217 27.05 - Set New Item 6167
on 9 mtr PSCC Poles of 300kG WL - MS
Single Pole Mounted Transformer kit for 25 kVA
218 27.06 - Set New Item 8151
on 9 mtr PSCC Poles of 300kG WL - GI
28 GOS
219 28.01 11kV, 200Amps Single Break GOS 304212 Set 7320 6951
11kV, 200Amps Single Break GOS(Modified for Will be included
220 28.02 New Item
making footpath free) on the proc rate
11kV, 200Amps Single Break GOS, Vertically
221 28.03 304213 Set 10632 10096
Operated
222 28.04 11kV, 400Amps Double Break GOS 304224 Set 16467 15637
H - Frame Set for 11kV, 200Amps Single Break
223 28.05 279149 Set 3330 2895
GOS Mounting - MS
H - Frame Set for 11kV, 200Amps Single Break
224 28.06 280149 Set 4220 3674
GOS Mounting - GI
Male and Female contacts with B&N for 11kV
225 28.07 503000 Set 2518 2518
200A GOS (3 Male & 3 Female contacts each)
226 28.08 11kV 400Amps Special Roaster GOS 304204 Set 12613 11977
227 28.09 Insulated GOS Rods 503211 No 342 342
29 DOLO Cutouts
11kV DOLO Cutouts Conventional to Erstwhile Set/3
228 29.01 302011 4288 4494
KEB Specification No
Set/3
229 29.02 11kV DOLO Cutouts REC Specification 302021 3396 3396
No
30 DP Sets (2 Pole Strucrure Kit)
230 30.01 DP Sets - MS 279100 Set 4475 3755
231 30.02 DP Sets - GI 280100 Set 5669 4935
31 3 Pole Structure Kit
232 31.01 3 Pole Structure Material - MS 279015 Set 10755 9350
233 31.02 3 Pole Structure Material - GI 280015 Set 13617 11855
32 C - Type Wedge Connectors (Fired)
234 32.01 Rabbit to Rabbit ACSR 285570 Set 391 338
235 32.02 Coyote to Coyote ACSR 285575 Set 969 836
236 32.03 Rabbit to Coyote ACSR 285571 Set 976 842
33 H - Clamps
237 33.01 Rabbit to Rabbit ACSR 285585 No 80 69
238 33.02 Coyote to Coyote ACSR 285587 No 398 344
239 33.03 Rabbit to Coyote ACSR 285586 No 377 325
240 33.04 Two Hole Paddle (Rabbit ACSR) 285590 No 311 268
241 33.05 Microwedge Connector 285594 No 101 88
34 LT Feeder Piller Box
242 34.01 LT Feeder Piller Box 8 Way with Cutouts 300308 No 40000 40000
243 34.02 LT Feeder Piller Box 12 Way with Cutouts 300312 No 48000 48000

244 34.03 Low Voltage Link Box - 2 Way 300315 No Will be intimated

245 34.04 Low Voltage Link Box - 4 Way 300316 No 146025


35 LT Spacers
246 35.01 LT Line Spacers (4 Wire) 284502 No 41 65

247 35.02 LT Line Spacers (2 Wire) 281504 No 25 39

248 35.03 LT Spacer for TC Wiring 284503 No 24 38

Armoured XLPE insulated LT UG Cable


36
1.1kV Class as per specification

249 36.01 6 Sqmm, 2 Core 287054 Km 43057

250 36.02 10 Sqmm, 2 Core 287055 Km 54334

251 36.03 10 Sqmm, 4 Core 287205 Km 71551

252 36.04 16 Sqmm, 2 Core 287056 Km 56956

253 36.05 16 Sqmm, 4 Core 287206 Km 90529

254 36.06 25 Sqmm, 2 Core 287057 Km 81930

255 36.07 25 Sqmm, 4 Core 287207 Km 109778


Will be finalised
256 36.08 50 Sqmm, 4 Core 287209 Km 144591
by committee
257 36.09 70 Sqmm, 3.5 Core 287210 Km 241512

258 36.10 95 Sqmm, 3.5 Core 287211 Km 339689

259 36.11 120 Sqmm, 3.5 Core 287212 Km 378559

260 36.12 150 Sqmm, 3.5 Core 287213 Km 430906

261 36.13 185 Sqmm, 3.5 Core 287214 Km 546711

262 36.14 240 Sqmm, 3.5 Core 287216 Km 751939

263 36.15 400 Sqmm, 3.5 Core 287218 Km 1040069


Compression type Aluminium Tubular
37 in Line Connector for Aluminum
Conductor
265 37.01 10 Sqmm 288605 No 3 3
266 37.02 16 Sqmm 288606 No 3 3
267 37.03 25 Sqmm 288607 No 4 4
268 37.04 35 Sqmm 288608 No 4 4
269 37.05 50 Sqmm 288609 No 6 6
270 37.06 70 Sqmm 288610 No 10 10
271 37.07 95 Sqmm 288611 No 11 11
272 37.08 120 Sqmm 288612 No 16 16
273 37.09 150 Sqmm 288613 No 24 24
274 37.10 185 Sqmm 288614 No 29 29
275 37.11 240 Sqmm 288616 No 48 48
276 37.12 400 Sqmm 288617 No 100 100

Straight Through Jointing Kits


38
Suitable for 1.1kV Class LT UG Cables
Epoxy Type
277 38.01 10 Sqmm, 2 Core 288170 Set 553 553
278 38.02 10 Sqmm, 4 Core 288174 Set 553 553
279 38.03 16 Sqmm, 2 Core 288171 Set 553 553
280 38.04 16 Sqmm, 4 Core 288175 Set 553 553
281 38.05 25 Sqmm, 2 Core 288172 Set 553 553
282 38.06 25 Sqmm, 4 Core 288176 Set 595 595
283 38.07 50 Sqmm, 4 Core 288178 Set 678 678
284 38.08 70 Sqmm, 3.5/4 Core 288179 Set 836 836
285 38.09 95 Sqmm, 3.5/4 Core 288180 Set 836 836
286 38.1 120 Sqmm, 3.5/4 Core 288181 Set 1319 1319
287 38.11 185 Sqmm, 3.5/4 Core 288183 Set 1362 1362
288 38.12 240 Sqmm,3.5/4 Core 288185 Set 1737 1737
289 38.13 400 Sqmm 3.5/4 Core 288187 Set 2573 2573
HS Type
290 38.14 up to 6 Sqmm 288190 Kit 500 500
291 38.15 10 to 16 Sqmm 288191 Kit 500 500
292 38.16 25 to 35 Sqmm 288192 Kit 650 650
293 38.17 50 to 95 Sqmm 288193 Kit 1000 1000
294 38.18 120 to 225 Sqmm 288194 Kit 1200 1200
295 38.19 240 to 300 Sqmm 288195 Kit 1400 1400
296 38.20 400 Sqmm 288196 Kit 2000 2000

Epoxy Terminating Kit (Pothead)


39
suitable for 1.1kV Class LT UG Cables
297 39.01 Up to 4C x 50 Sqmm 288150 Set 307 307
298 39.02 3.5 x 70/95/120 Sqmm 288159 Set 362 362
299 39.03 3.5 x 150/185 Sqmm 288163 Set 455 455
300 39.04 3.5 x 225/240/300 Sqmm 288165 Set 557 557
301 39.05 3.5 x 400/500 Sqmm 288166 Set 678 678

Cast Iron Terminating Kit (Pothead)


40
Suitable for 1.1kV Class LT UG Cables
302 40.01 2.5 to 25 Sqmm 288168 Set 186 186
303 40.02 35 to 95 Sqmm 288169 Set 289 289
41 11kV, 3 Core, XLPE HTUG Cable (FLAT Armoured)

304 41.01 95 Sqmm 287340 Km 548860 548860


305 41.02 120 Sqmm 287342 Km 843170 697000
306 41.03 240 Sqmm 287345 Km 1038890 1038890
307 41.04 400 Sqmm 287350 Km 1632500 1565000

11kV, 3 Core, XLPE HTUG Cable


42
(ROUND Armoured)

308 42.01 95 Sqmm 287400 Km 675110 675110


309 42.02 120 Sqmm 287402 Km 1040920 871000
310 42.03 240 Sqmm 287405 Km 1279950 1279950
311 42.04 400 Sqmm 287410 Km 2015220 1956000
312 42.05 11kV Cables Fault Locating Equipments 440300 No 4222800 4222800
43 1.1kV, XLPE LTUG Cable
313 43.01 3.5C x 25 Sqmm 287257 Km 138000 122300
314 43.02 3.5C x 95 Sqmm 287261 Km 371000 319500
315 43.03 3.5C x 150 Sqmm 287262 Km 548000 468100
316 43.04 3.5C x 185 Sqmm 287263 Km 680000 579500
317 43.05 3.5C x 240 Sqmm 287264 Km 849000 718800
11kV Auto Reclosures and
44 Sectionalizers with Remote
Communication Facility
11kV, 630A, 12.5KA Auto reclosures with control
pannel including necessary hardware structure
318 44.01 302510 Set 918356 918356
protection system etc., as per specification
(MESCOM)
11kV, 12.5KA Sectionalizer with control box
319 44.02 having control logic with necessary hardware etc., 312550 Set 677499 677499
as per specification (MESCOM)
11kV, 230V, 2 Phase, 300VA control transformer
320 44.03 312551 Set 12945 12945
for providing auxillary power
11kV/√3/110V/√3, 1 Phase metering PT
321 44.04 class - 1, 100VA per Phase for measurement of 312552 Set 35303 35303
voltage
GSM modem with connecting cable for remote
322 44.05 312553 Set 14121 14121
communicating capabilities
Fabrication & supply of structrual steel including
323 44.06 312554 Set 7825 7825
painting etc.,
9.6kV, 200A long duration porcelien housed
324 44.07 312555 Each 1569 1569
Surge arrestors
Conventional RMUs (VCB Type) DAS
45
Compatable
3 Way RMU, 2OD + 1VL (One Incomer + One
325 45.01 302480 Set 1341910
Breakers + One Outgoing) with DAS Specification

4 Way RMU, 2OD + 2VL (One Incomer + Two


326 45.02 302481 Set 1756090
Breakers + One Outgoing) with DAS Specification

5 Way RMU, 2OD + 3VL (One Incomer + Three


327 45.03 302482 Set 2170280
Breakers + One Outgoing) with DAS Specification

6 Way RMU, 2OD + 4VL (One Incomer + Four


328 45.04 302483 Set 2584460
Breakers + One Outgoing) with DAS Specification
Will be intimated
329 45.05 Single I/C Panel with DAS Specification 302484 Set 364210
5 Way RMU, 2OD + 3VL (One Incomer + Three
330 45.06 Breakers + One Outgoing), 350MVA, 800Amps 302310 Set 1638232
with Cu Busbar
5 Way RMU, 2OD + 3VL (One Incomer + Three
331 45.07 Breakers + One Outgoing), 350MVA, 800Amps 302311 Set 1584750
with Al Busbar
4 Way RMU, 2OD + 2VL (One Incomer + Two
332 45.08 302312 Set 1316970
Breakers + One Outgoing)
3 Way RMU, 2OD + 1VL (One Incomer + One
333 45.09 302313 Set 620090
Breakers + One Outgoing)
46 Conventional RMUs OD
334 46.01 One Breaker (VL) Panel with Cu Busbar 302315 No 333789

335 46.02 One Breaker (VL) Panel with Al Busbar 302316 No 320445
3 Way RMU, 2OD + 1VL (One Incomer + One
336 46.03 Breakers + One Outgoing), 350MVA, 800Amps 302320 Set 983160
with Cu Busbar
3 Way RMU, 2OD + 1VL (One Incomer + One
337 46.04 Breakers + One Outgoing), 350MVA, 800Amps 302321 Set 943860
with Al Busbar Will be intimated
3 Way RMU, 2OD + 1VL (One Incomer + One
338 46.05 Breakers + One Outgoing), 250MVA, 400Amps, 302325 Set 908480
VCB Type with Cu Busbar
3 Way RMU, 2OD + 1VL (One Incomer + One
339 46.06 Breakers + One Outgoing), 250MVA, 400Amps, 302326 Set 876297
VCB Type with Al Busbar
Retrofitting of MEI make oil switch type OD with
340 46.07 302470 No 171590
VCB

47 Conventional RMU Spares (VCB Type)


341 47.01 Bus Support Insulator with Stem 506505 No 1095 To be deleted
CTs Trom Bone Type, 11kV Class, 200 - 100/5A,
342 47.02 506520 No 18755 To be deleted
VA - 15, Class 5P - 10
CTs resin cast, 11kV Class,400 - 200/5A, UA15,
343 47.03 506525 No 18755 To be deleted
Class 5P - 10
344 47.04 Spout Grid Insulator Assembly (Back) 506530 No 4247 To be deleted
345 47.05 Spout Grid Insulator Assembly (Front) 506535 No 4247 To be deleted
346 47.06 PT Insulator (Spout) 3 Nos 506540 No 448 To be deleted
347 47.07 Shunt Trip Coil 506545 No 757 To be deleted
348 47.08 Closing Coil 506550 No 757 To be deleted
349 47.09 Plug Assembly for grid 800A, 6 Nos 506555 No 1579 To be deleted
350 47.10 Para Plast Compound 506560 No 750 To be deleted
PT Fuse(NT) 11kV/V3 Amps without Stem, VTF
351 47.11 506565 No 2837 To be deleted
Type - 11
352 47.12 Insulated Housing 506510 No 27386 To be deleted
353 47.13 Switch Insulators Left/Right/Centre 506515 No 5963 To be deleted
354 47.14 Vacuum Interruptor 20kA 506570 No 23958 To be deleted
355 47.15 Flower Contact 506580 No 1065 To be deleted
48 For Schneider make RMU To be deleted
356 48.01 Tripping Coil 506445 No 9345 To be deleted
357 48.02 VIP Relay 506481 No 51398 To be deleted
358 48.03 Live Cable Indicator 440615 No 3894 To be deleted

359 48.04 11KV Fault Passage Indicator for Overhead Line 302580 No 14810 14810

Compact RMUs, (VCB/SF6 Type) with


49
Al Busbar

3 Way RMU, 2OD + 1VL, One Incomer + One


360 49.01 302340 Unit 739453
Breaker + One Outgoing, 350MVA, 650Amps

4 Way RMU, 2OD + 2VL (One Incomer + Two


361 49.02 302345 Unit 1050370
Breakers + One Outgoing), 350MVA, 650Amps
Will be intimated
5 Way RMU, 2OD + 3VL (One Incomer + Three
362 49.03 302350 Unit 1355749
Breakers + One Outgoing), 350MVA, 650Amps
6 Way RMU, 2OD + 4 VL (One Incomer + Four
363 49.04 302355 Unit 1661128
Breakers + One Outgoing), 350MVA, 650Amps
364 49.05 1OD for RMU 302335 Unit 266070
365 49.06 1VL for 350MVA, 650Amps RMU 302358 Unit 310917
50 Load Break Switches
366 50.01 Load Break Switches Only Without Panel 506491 Unit 41210
Will be intimated
367 50.02 Load Break Switches with Panel 506492 Unit 89830
368 50.03 3 Way Load Break Switch 506493 Unit 290610
51 Aerial Bunched Cable (ABC)
369 11kV, HT Aerial Bunched Cable
3x95+1x70 Sqmm (Bare/Insulated messenger
370 51.01 284791 Km 700820 631000
wire)
3x120+1x95 Sqmm (Bare/Insulated messenger
371 51.02 284792 Km 811368 769000
wire)

LT Aerial Bunched Cable

3x95+1x70+1x16 Sqmm Street light (Insulated


372 51.03 284819 Km 345902 410000
messenger cum Neutral)
3x95+1x70+1x25 Sqmm Street light (Insulated
373 51.04 284811 Km 356375 422400
messenger cum Neutral)
3x95+1x70+1x35 Sqmm Street light (Insulated
374 51.05 284812 Km 365685 433300
messenger cum Neutral)
52 Covered Conducor
375 52.01 Covered Conductor Km Will be intimated Will be Intimated

53 Accessories for ABC Cables


Suspension clamp suitable for insulated
376 53.01 No New Item 325
Messsenger wire of size 25 to 95Sq mm
11kV, AB Cable Straight thru' joint kit suitable for
377 53.02 284853 No 2963 deleted
95 Sqmm
11kV, AB Cable Straight thru' joint kit suitable for set /
378 53.03 New Item 5650
95 Sqmm 3 nos
11kV, AB Cable Straight thru' joint kit suitable for set /
379 53.04 New Item 6000
120 Sqmm 3 nos
380 53.05 11kV ABC - T Jointing kit 95 - 120 Sqmm 284863 No 3757 deleted
381 53.06 11kV ABC Termination kit 95 - 120 Sqmm 284873 No 1879 2100
382 53.07 Surge Arester( for AB Cable) 303100 No 803 593
383 53.08 Ground Connection for Messenger Wire 284880 No 122 122
384 53.09 Anchor Sleeve for Messenger Wire 284885 No 23 Deleted
Single Phase Distribution Box for 20
385 53.1 284820 No 1806 2065
Connections(SMC)
Single Phase Distribution Box for 10
386 53.11 284818 No 2065 1950
Connections(SMC/polycarbonate)
Three Phase Distribution Box for 5
387 53.12 284815 No 2065 2065
Connections(SMC/Polycarbonate)
Three Phase Distribution Box for 6
388 53.13 1987 2065
Connections(SMC)
Piercing Connector Suitable for 16 Sqmm - 95
389 53.14 284822 No 228 228
Sqmm AB Cable - Service Connections
Piercing Connector Suitable for 16 Sqmm - 95
390 53.15 284223 No 160 160
Sqmm AB Cable - Street Light Connections
Piercing Connector Suitable for 25 Sqmm - 95
391 53.16 284855 No 267 267
Sqmm AB Cable - Main to Main Connections

Piercing Connector Suitable for 50 Sqmm - 150


392 53.17 284865 No 267 300
Sqmm AB Cable - Main to Main Connections

393 53.18 Universal Hook and Bolts & Nuts 284284 No 305 305
Dead End Clamp/Anchor Clamp Assembly 25 to
394 53.19 95 Sqmm Bare Messenger(Exclusive of pole clamp 284825 No 152 131
and eye hook)
Dead End Clamp/Anchor Clamp Assembly 16 to
395 53.20 70 Sqmm Bare Messenger(Exclusive of pole clamp New Item 200
and eye hook)
Dead End Clamp/Anchor Clamp Assembly 70 to
396 53.21 210 Sqmm Bare Messenger(Exclusive of pole New Item 300
clamp and eye hook)

Suspension Clamp Assembly 25 to 95 Sqmm Bare


397 53.22 284826 No 305 deleted
Messenger

Suspension Clamp Assembly16 to 70 Sqmm Bare


398 53.23 New Item 190
Messenger(Exclusive of pole clamp and eye hook)

Suspension Clamp Assembly 70 to 210 Sqmm


399 53.24 Bare Messenger(Exclusive of pole clamp and eye New Item 305
hook)
400 53.25 Pre - Insulated lugs - CPTAU for 120 Sqmm 284836 No 446 385
401 53.26 Pre - Insulated Lugs - CPTAU for 95 Sqmm 284837 No 392 338
402 53.27 Pre - Insulated Lugs - CPTAU for 70 Sqmm 284827 No 343 295
403 53.28 Pre - Insulated Lugs - CPTAU for 50 Sqmm 284828 No 305 262
404 53.29 Pre - Insulated Lugs - CPTAU for 25 Sqmm 284834 No 286 246
405 53.30 Pre - Insulated Lugs - CPTAU for 16 Sqmm 284835 No 141 122
406 53.31 Tee - Connectors - KZ3 95 284829 No 392 338
Straight Joints Suitable for 95 Sqmm, LT ABC -
407 53.32 284832 No 310 310
MJPT Type
Straight Joints Suitable for 70 Sqmm, LT ABC - No/ 1
408 53.33 284830 289 289
MJPT Type core
Straight Joints Suitable for50 Sqmm, LT ABC -
409 53.34 284831 No 271 271
MJPT Type
Straight Joints Suitable for 25 Sqmm, LT ABC -
410 53.35 No New Item 250
MJPT Type
Straight Joints Suitable for 16 Sqmm, LT, ABC -
411 53.36 284840 No 181 181
MJPT Type
412 53.37 End Cap for 50/70 Sqmm 284833 No 19 19
100
413 53.38 Nylon cable Tie New Item 400
Nos

414 53.39 Pole Clamp for HT/LT AB cables New Item 100

415 53.40 Eye Hook (Flat Type) for fixing clamps New Item 90
11kV Jointing and Cable Termination
54
Kits
Heat Shrinkable Type Transition Jointing
Kit for XLPE Cable
416 54.01 3x95 Sqmm 288312 Set 8815 8815
417 54.02 3x240 Sqmm 288314 Set 10894 10894
418 54.03 3x400 Sqmm 288315 Set 11095 11095
Heat Shrinkable Indoor Type Cable
Termination Kit for XLPE Cable
419 54.04 3x95 Sqmm 288332 Set 2753 2753
420 54.05 3x240 Sqmm 288334 Set 3450 3450
421 54.06 3x400 Sqmm 288336 Set 3540 3540
Heat Shrinkable Outdoor Type Cable
Termination Kit for XLPE Cable
422 54.07 3x95 Sqmm 288302 Set 2990 2990
423 54.08 3x240 Sqmm 288304 Set 3910 3910
424 54.09 3x400 Sqmm 288305 Set 3940 3940
Heat Shrinkable Indoor Type Cable
Termination Kit for PILC Cable
425 54.10 3x95 Sqmm 288462 Set 2307 2307
426 54.11 3x240 Sqmm 288464 Set 2478 2478
427 54.12 3x400 Sqmm 288465 Set 2530 2530
Heat Shrinkable Outdoor Type Cable
Termination Kit for PILC Cable
428 54.13 3x95 Sqmm 288456 Set 2924 2924
429 54.14 3x240 Sqmm 288458 Set 3669 3669
430 54.15 3x400 Sqmm 288460 Set 3685 3685
Heat Shrinkable Straight Through Jointing
Kits for XLPE Cable with Copper Lugs & Al
Ferrules
431 54.16 3x95 Sqmm 288322 Set 5375 5375
432 54.17 3x240 Sqmm 288324 Set 6555 6555
433 54.18 3x400 Sqmm 288329 Set 8050 8050
Heat Shrinkable Straight Through Jointing
Kits for PILC Cable with Copper Lugs & Al
Ferrules
434 54.19 3x95 Sqmm 288450 Set 5734 5734
435 54.20 3x240 Sqmm 288452 Set 6479 6479
436 54.21 3x400 Sqmm 288453 Set 7827 7827
55 Service Connection Accessories
Pole Mounted Fibre Glass Reinforced Aerial Fuse
437 55.01 612614 No 1022 1022
Board 60Amps - 3 Way
Pole Mounted Fibre Glass Reinforced Aerial Fuse
438 55.02 612615 No 730 730
Board 30Amps - 3 Way
439 55.03 FGRP Aerial Fuse Boards 30Amps - 4 Way 612617 No 952 952
440 55.04 FGRP Aerial Fuse Boards 30Amps - 5 Way 612618 No 1077 1077
441 55.05 FGRP Aerial Fuse Boards 30Amps - 6 Way 612616 No 1180 1180
56 LT Service Connector
442 56.01 For Weasel 288502 No 33 28
443 56.02 For Rabbit 288503 No 33 28
57 PVC Pipes
A. Pipes
444 57.01 PVC Pipe - 20 mm Dia 778020 Mtr 21 21
445 57.02 PVC Pipe - 25 mm Dia 778025 Mtr 27 27
446 57.03 PVC Pipe - 32 mm Dia 778032 Mtr 45 45
447 57.04 PVC Pipe - 40 mm Dia 778040 Mtr 50 50
448 57.05 PVC Pipe - 50 mm Dia 778050 Mtr 56 56
449 57.06 PVC Pipe - 63 mm Dia 778063 Mtr 74 74
450 57.07 PVC Pipe - 75 mm Dia 778075 Mtr 88 88
451 57.08 PVC Pipe - 80 mm Dia 778080 Mtr 123 123
452 57.09 PVC Pipe - 100 mm Dia 778100 Mtr 140 140
453 57.10 PVC Pipe - 150 mm Dia 778105 Mtr 291 291
454 57.11 PVC Pipe - 200 mm Dia 778110 Mtr 440 440
B. Bends
455 57.12 PVC Bend - 20 mm Dia 778000 No 7 7
456 57.13 PVC Bend - 25 mm Dia 778001 No 10 10
457 57.14 PVC Bend - 32 mm Dia 778002 No 22 22
458 57.15 PVC Bend - 40 mm Dia 778003 No 35 35
459 57.16 PVC Bend - 50 mm Dia 778004 No 54 54
460 57.17 PVC Bend - 63 mm Dia 778005 No 65 65
461 57.18 PVC Bend - 75 mm Dia 778006 No 71 71
462 57.19 PVC Bend - 80 mm Dia 778007 No 100 100
463 57.20 PVC Bend - 100 mm Dia 778008 No 151 151
464 57.21 PVC Bend - 150 mm Dia 778009 No 200 200
465 57.22 PVC Bend - 200 mm Dia 778010 No 254 254
58 GI Pipes B - Class
466 58.01 GI Pipe - 20 mm Dia 768040 Mtr 110 110
467 58.02 GI Pipe - 25 mm Dia 768042 Mtr 155 155
468 58.03 GI Pipe - 32 mm Dia 768043 Mtr 209 209
469 58.04 GI Pipe - 40 mm Dia 768044 Mtr 220 220
470 58.05 GI Pipe - 50 mm Dia 768046 Mtr 286 286
471 58.06 GI Pipe - 63 mm Dia 768047 Mtr 310 310
472 58.07 GI Pipe - 65 mm Dia 768048 Mtr 409 409
473 58.08 GI Pipe - 100 mm Dia 768052 Mtr 1143 1143
474 58.09 GI Pipe - 150 mm Dia 768058 Mtr 1144 1144
PVC Insulated & Sheathed Aluminium
59 Wires, Single Core Multistrand 1.1 kV
Class
100
475 59.01 PVC Wire - 2.5 Sqmm 289022 863 880
Mtr
100
476 59.02 PVC Wire - 4 Sqmm 289023 1045 1065
Mtr
100
477 59.03 PVC Wire - 6 Sqmm 289024 1264 1288
Mtr
100
478 59.04 PVC Wire - 10 Sqmm 289025 1713 1747
Mtr
PVC Insulated & Un-Sheathed
60 Aluminium Wires, Single Core
Multistrand 1.1 kV class
100
479 60.01 PVC Wire - 16 Sqmm 289026 2306 2352
Mtr
100
480 60.02 PVC Wire - 25 Sqmm 289027 3182 3246
Mtr
100
481 60.03 PVC Wire - 35 Sqmm 289028 3552 3624
Mtr
100
482 60.04 PVC Wire - 50 Sqmm 289029 4364 4451
Mtr
100
483 60.05 PVC Wire - 70 Sqmm 289030 6548 6680
Mtr
100
484 60.06 PVC Wire - 95 Sqmm 289031 8059 8200
Mtr
100
485 60.07 PVC Wire - 120 Sqmm 289032 10558 10753
Mtr
100
486 60.08 PVC Wire - 150 Sqmm 289033 12981 13240
Mtr
100
487 60.09 PVC Wire - 185 Sqmm 289034 14978 15277
Mtr
488 60.10 PVC Wire - 240 Sqmm 289036 Coil 19424 19945
61 Fuse Wires
489 61.01 Tinned Copper Fuse Wire, 5A 625020 Kg 780 700
490 61.02 Tinned Copper Fuse Wire, 10A 625230 Kg 780 700
491 61.03 Tinned Copper Fuse Wire, 20A 625250 Kg 780 700
492 61.04 Tinned Copper Fuse Wire, 100A 625075 Kg 780 700
62 Porcelain cut outs (500 Volts)
493 62.01 15/16A 300003 No 38 38
494 62.02 30/32A 300005 No 53 53
495 62.03 60/63A 300007 No 158 158
496 62.04 100A 300010 No 283 283
497 62.05 200A 300020 No 450 450
498 64.06 300A 300030 No 825 825
Grounding Materials for RMUs &
65
Transformers
Pipe Grounding
GI Grounding pipe, B - Class, 40mm dia, 2.5mtrs
499 65.01 long, 2.9mm thick with bolts nuts, GI Strips and 281674 No 605 527
washers complete
GI Grounding pipe, B - Class, 40mm dia, 2.5mtrs
500 65.02 long, 3.2mm thick with bolts nuts, GI Strips and No New Item Will be Intimated
washers complete
Good Quality well burnt Charcoal for grounding
501 65.03 purposes packed in non returnable gunny bags of 600095 No 450 450
30kg each
Good Quality Salt for grounding purposes packed
502 65.04 607054 Bag 300 300
in 50kg gunny bags
Rod Earthing
Rod type of earthing using 40mm dia, 3mtr long
MS rod as ground rod, in earth pit of 300mm
width and 3300mm depth and using 50x6mm flat
503 65.04 281685 No 2000 2000
welded to ground rod as terminal & connected to
equipment ground terminal using pvc Al wire as
specified
50 kg
504 65.05 Bentonite clay slurry for earthing in 50 kg bags 607220 400 400
Bag
66 Alkathine tube
Transparent Alkathine tube 19mm dia, 2mm
505 66.01 821900 Coil 500 500
thick in coils of 30 mtrs
67 Measuring Equipments
High precision Single phase Electromechanical
506 67.01 meters with magnetic suspension 2.5 - 10A, Class- 357001 No Deleted Deleted
2 accuracy
High precision 3 phase Electromechanical meters
507 67.02 with magnetic suspension 5-20A, Class-2 357021 No Deleted Deleted
accuracy
LT Electronic Tri - Vector Meter 5A, Class-0.5/1.0
508 67.03 357511 No Deleted Deleted
accuracy
LT Electronic Tri - Vector Meter 5A, Class-0.5
509 67.04 357510 No 3000 2250
accuracy
HT Electronic Tri - Vector Meter 5A, Class-0.5
510 67.05 357512 No 3463 2600
accuracy
HT Electronic Tri - Vector Meter 5A, Class-0.2
511 67.06 357500 No 15750 11658
accuracy with ABT features
Electronic Meter, 5-10A/5-20A, SPh Class-1
512 67.07 357003 No Deleted Deleted
Accuracy
LT Single phase 5-30A, DLMS complaint static
513 67.08 357006 No 905 733
energy meter, class-1.0 Accuracy
Electronic Meter, 2.5-10A/5-20A, 3 Ph Class-1
514 67.09 357205 No Deleted Deleted
Accuracy
LT AC Three Phase 4 wire, 5-30A Static whole
515 67.10 unidirectional complaint energy meter, Class – 1.0 357531 No 2499 2450
Accuracy

516 67.11 Electronic Meter, 10-40A, 3 Ph Class-1 Accuracy 357201 No Deleted Deleted

LT Three phase, 4wire, CT Operated DLMS


517 67.12 357519 No 3000 2450
complaint ETV meter-/5, class 05s Accuracy
Electronic Meter, 5-20/30A, 3 Ph 4 wire Class - 1
518 67.13 357200 No Deleted Deleted
Accuracy (whole current)
Electronic Meter, 10-40/60A, 3 Ph Class-1, 4 wire
519 67.14 357206 No Deleted Deleted
Accuracy (whole current)
Electromechanical Energy Meter - 3 Ph, 5-20A,
520 67.15 357122 No Deleted Deleted
Class-2 Accuracy, for IP Sets
LT, S.Ph, 5-30 A Static Energy Meter of Accuracy
521 67.16 357015 No Deleted Deleted
Class in retail out lets of BESCOM
522 67.17 Pre - paid Energy meter single phase, 5-30A 357580 No 10733 10733
523 67.18 Pre - paid Energy meter three phase, 5-30A 357585 No 13532 13532
3 phase 4 wire static meter (CT, PT operated) 3 x
524 67.19 63.5 V, 5 Amps or 1 Amps class 0.2s with Rs - 357514 No 14745 14745
485 & ABT features
LT Three phase Four Wire 5-30A Thread through
type composite Meter Housing Box consisting of
ETV Meter with AMR comply and LTCT with built
525 67.20 357515 No 19135 19135
in GSM/GPRS modem (as per technical
specification ) upto 100kVA Distribution
Transformer.
Numerical Over Current & Earth Fault Protecion
526 67.21 357517 No 10126 10126
Relay with Accessories

Meter Protection/Tamper Proof Boxes


68
(MS) for LT Installations above 40 HP
Meter Protection/Tamper Proof box with busbar,
527 68.01 for LT 3 Ph with CT Ratio 50/5A, Class-1 358040 No 6720 6720
Accuracy
Meter Protection/Tamper Proof box with busbar,
528 68.02 for LT 3 Ph with CT Ratio 75/5A, Class-1 358023 No 6240 6240
Accuracy
Meter Protection/Tamper Proof box with busbar,
529 68.03 for LT 3 Ph with CT Ratio 100/5A, Class-1 358030 No 5952 5952
Accuracy
LT Metering Box for housing the ETV Meters
530 68.04 358050 No 4000 4000
without CT's busbar wiring etc;
531 68.05 Pillfer proof box for below 40HP Installations 612655 No 322 322

532 68.06 SMC Meter protection box 358005 No 480 will be intimated

LT SMC Metering box without CTs with wiring


arrangement Modems compatible for DLMS
533 68.07 358076 No 4545 4000
meters with RS232 for LT installation

SMC Street Lighting Metering Box with Automatic


534 68.08 Control Swith, Contactors with Single Phase 5-30 358078 No 6500 will be intimated
Amps meter & 50/5A CT
535 68.09 Numerical Poly Carbonate Seals 626234 No 8 8
536 68.10 Meter Sealing Wire 626500 Kg 167 167
537 68.11 High security label seal 357590 No 6 6
538 68.12 Poly carbonate sealing bits with out number 626233 No 6 6
69 LT Current Transformers
CT Ratio - 25/5A, Class-1 Accuracy, 3.75 VA,
539 69.01 336005 No 619 558
Ring type
CT Ratio - 30/5A, Class-1 Accuracy, 3.75 VA,
540 69.02 336006 No 619 558
Ring type
CT Ratio - 50/5A, Class-1 Accuracy, 3.75 VA,
541 69.03 336010 No 615 554
Ring type
CT Ratio - 75/5A, Class-1 Accuracy, 3.75 VA,
542 69.04 336015 No 512 461
Ring type
CT Ratio - 50/5A, Class-0.5 Accuracy, 3.75 VA,
543 69.05 New Item 550
Ring type
CT Ratio - 75/5A, Class-0.5 Accuracy, 3.75 VA,
544 69.06 New Item 350
Ring type
CT Ratio - 100/5A, Class-0.5 Accuracy, 3.75 VA,
545 69.07 336020 No 454 408
Ring type
CT Ratio - 150/5A, Class-0.5 Accuracy, 3.75 VA,
546 69.08 336025 No 341 306
Ring type
CT Ratio - 200/5A, Class-0.5 Accuracy, 3.75 VA,
547 69.09 336030 No 400 360
Ring type
CT Ratio - 300/5A, Class-0.5 Accuracy, 3.75VA,
548 69.10 336035 No 400 360
Ring type
CT Ratio - 400/5A, Class-0.5 Accuracy, 3.75 VA,
549 69.11 336040 No 400 360
Ring type
CT Ratio - 600/5A, Class-0.5 Accuracy, 3.75VA,
550 69.12 336046 No 450 405
Ring type
CT Ratio - 800/5A, Class-0.5 Accuracy, 3.75 VA,
551 69.13 336050 No 450 405
Ring type

70 Instrument Transformers (PTs & CTs)


11KV PTs

PT 11kV/110V, 50VA, Insulation level 15/35/95


552 70.01 335230 No 8631 8631
kV as per IS 3156, Accuracy class 0.5

PT 11KV/rt3/110V/rt3, 25VA, Insulation level


553 70.02 No New Item 9200
15/35/95 kV as per IS 3156, Accuracy class 0.2

554 70.03 PT 11kV Station Type 335220 No 24110 24110


11KV CTs (Secondary -5A) for 3 phase-3
71
wire Metering
555 71.01 CT - 11kV, 2.5/5A, Accuracy Class 0.5 336292 No 4000 4000
556 71.02 CT - 11kV, 5/5A, Accuracy Class 0.5 336294 No 4000 4000
557 71.03 CT - 11kV, 7.5/5A, Accuracy Class 0.5 336296 No 4000 4000
558 71.04 CT - 11kV, 10/5A, Accuracy Class 0.5 336302 No 4000 4000
559 71.05 CT - 11kV, 12.5/5A, Accuracy Class 0.5 336303 No 4000 4000
560 71.06 CT - 11kV, 15/5A, Accuracy Class 0.5 336304 No 4000 4000
561 71.07 CT - 11kV, 20/5A, Accuracy Class 0.5 336306 No 4250 4250
562 71.08 CT - 11kV, 25/5A, Accuracy Class 0.5 336308 No 4250 4250
563 71.09 CT - 11kV, 30/5A, Accuracy Class 0.5 336310 No 4250 4250
564 71.10 CT - 11kV, 40/5A, Accuracy Class 0.5 336341 No 4250 4250
565 71.11 CT - 11kV, 50/5A, Accuracy Class 0.5 336309 No 4250 4250
566 71.12 CT - 11kV, 60/5A, Accuracy Class 0.5 336342 No 4250 4250
567 71.13 CT - 11kV, 75/5A, Accuracy Class 0.5 336315 No 4500 4500
568 71.14 CT - 11kV, 100/5A, Accuracy Class 0.5 336321 No 4500 4500
569 71.15 CT - 11kV, 150/5A, Accuracy Class 0.5 336375 No 4500 4500
570 71.16 CT - 11kV, 200/5A, Accuracy Class 0.5 336325 No 4500 4500
571 71.17 CT - 11kV, 400/5A, Accuracy Class 0.5 336335 No 4750 4750
572 71.18 11 KV CTs (Secondary 1A)
CT-11KV, 1.25/1A to 2.5/1A, Burden:2.5VA
573 71.19 No New Item 8120
Accuracy Class 0.2
CT-11KV, 5/1A to 100/1A, Burden:2.5VA
574 71.20 No New Item 6960
Accuracy Class 0.2
CT-11KV, 125/1A to 200/1A, Burden:2.5VA
575 71.21 No New Item 7450
Accuracy Class 0.2
CT-11KV, 225/1A to 400/1A, Burden:2.5VA
576 71.22 No New Item 8120
Accuracy Class 0.2
72 HT Metering Equipments
HT Metering cubicle, 11kV Class, All single
ratio CTs including ETV Meter (2CT 2PT)
577 72.01 Without Load Break Switch 358350 No 63840 63840
578 72.02 With Load Break Switch 358320 No 124500 124500

11kV HT Metering Panel 3 CT 3 PT for 3 Phase 4


Wire Metering With Transparent Cover TTB, with
579 72.03 30x8mm Cu Bus bars (HT Metering Box 358355 No 135585 135585
Fabricated out of 3mm MS Sheet duly epoxy
powder coated, Without Meter)

11kV HT Metering Panel 3 CT 3 PT for 3 Phase 4


Wire Metering With Transparent Cover TTB, with
580 72.04 30x8mm Cu Bus bars (HT Metering Box New Item 140585
Fabricated out of 3mm MS Sheet duly epoxy
powder coated, With Modem)

0.2 S Class ETV Meter with ABT Feature & DLMS


581 72.05 357518 No 20000 20000
Protocal with ToD for above
73 UPS on Line
582 73.01 1KVA 344901 Set 24821 24821
583 73.02 5KVA 344905 Set 91050 91050
74 Heavy Duty Copper Terminals
584 74.01 25 Sqmm Copper Terminals 288507 No 22 20
585 74.02 35 Sqmm Copper Terminals 288508 No 23 21
586 74.03 50 Sqmm Copper Terminals 288509 No 34 30
587 74.04 70 Sqmm Copper Terminals 288510 No 55 49
588 74.05 95 Sqmm Copper Terminals 288511 No 79 71
589 74.06 120 Sqmm Copper Terminals 288512 No 86 77
590 74.07 150 Sqmm Copper Terminals 288513 No 114 101
591 74.08 185 Sqmm Copper Terminals 288514 No 159 141
592 74.09 225 Sqmm Copper Terminals 288515 No 204 182
593 74.10 240 Sqmm Copper Terminals 288516 No 207 184
594 74.11 300 Sqmm Copper Terminals 288517 No 298 266
595 74.12 400 Sqmm Copper Terminals 288518 No 501 446
Heavy Duty Copper Terminals Long
75
Barrel
596 75.01 25 Sqmm Copper Terminals 288527 No 22 20
597 75.02 35 Sqmm Copper Terminals 288528 No 30 27
598 75.03 50 Sqmm Copper Terminals 288529 No 45 40
599 75.04 70 Sqmm Copper Terminals 288530 No 70 62
600 75.05 95 Sqmm Copper Terminals 288531 No 100 89
601 75.06 120 Sqmm Copper Terminals 288532 No 110 98
602 75.07 150 Sqmm Copper Terminals 288533 No 145 129
603 75.08 185 Sqmm Copper Terminals 288534 No 215 192
604 75.09 225 Sqmm Copper Terminals 288535 No 275 245
605 75.10 240 Sqmm Copper Terminals 288536 No 280 249
606 75.11 300 Sqmm Copper Terminals 288537 No 405 361
607 75.12 400 Sqmm Copper Terminals 288538 No 680 606
76 Al End Terminals (Lugs)
608 76.01 10 Sqmm 288630 No 3 3
609 76.02 16 Sqmm 288631 No 3 3
610 76.03 25 Sqmm 288632 No 4 4
611 76.04 32 Sqmm 288633 No 5 5
612 76.05 50 Sqmm 288634 No 9 8
613 76.06 70 Sqmm 288635 No 13 12
614 76.07 95 Sqmm 288636 No 17 15
615 76.08 120 Sqmm 288637 No 22 19
616 76.09 150 Sqmm 288638 No 26 22
617 76.10 185 Sqmm 288639 No 40 35
618 76.11 225 Sqmm 288640 No 44 38
619 76.12 240 Sqmm 288641 No 65 56
620 76.13 300 Sqmm 288642 No 77 66
621 76.14 400 Sqmm 288643 No 100 86
77 TOOLS AND PLANT
622 77.01 Battery Hydrometer 429810 No 100 100
623 77.02 Multimeter Electronic Type 359215 No 900 900
624 77.03 Multimeter Electromechanical Type 359210 No 1619 1619

Rubber Hand gloves 15kV, SEAMLESS


625 77.04 Confirming to ISS (Sample to be verified for 427252 Pair 985 985
seamless before approval) for electrical purpose

626 77.05 Thermometer (Wall Mounted) 430395 No 231 231


627 77.06 Portable Drilling Machine 410020 No 2150 2150
628 77.07 Megger 500 V 359400 No 2250 2250
629 77.08 Megger 2.5kV - 5kV 359450 No 4500 4500
630 77.09 Silica Gel 607056 Kg 170 170
631 77.10 Grounding Sticks/Rods (Earthing Rods) 427210 Set 1710 1710
632 77.11 Telescopic Earthing Rods 427215 Nos 1254 1254
633 77.12 Panel Indication Lamps 611972 No 12 12
634 77.13 Ring Spanners 424000 Set 1577 1577
635 77.14 Tube Spanners 424150 Set 600 600
636 77.15 Pipe Wrench 24 Inches Size 424410 No 788 788
637 77.16 Pipe Wrench 18 Inches Size 424408 No 300 300
638 77.17 Double End Spanner 424300 Set 283 283
639 77.18 Hack Saw Frames + B185 418170 No 100 100
640 77.19 Hand Torch 5 Celled 427405 No 120 120
641 77.20 Hand Torch 3 Celled 427403 No 60 60
642 77.21 Rechargable LED Hand Torch 427408 No 681 681

643 77.22 Portable Inflatable Emergency Lighting System 427435 No 1898135 deleted

644 77.23 Insulated cutting pilers 12 inches size 425040 No 200 200
645 77.24 Insulated cutting pilers 8 inches size 425041 No 152 152
646 77.25 Live Line Tester (HT) 440000 No 70 70
647 77.26 LT Line Tester 440005 No 38 38
648 77.27 High Voltage Detector 440008 No 15863 15863
649 77.28 Screw driver 18 Inches Size 425522 No 80 80
650 77.29 Screw driver 12 Inches Size 425521 No 69 69
651 77.30 Screw driver 8 Inches Size 425518 No 72 72
652 77.31 Hammer 8 Lbs 418141 No 200 200
653 77.32 Hammer 2 Lbs 418100 No 150 150
654 77.33 Allen Keys 424260 No 192 192
655 77.34 Adjustabale Screw Spanner 8 Inches 424364 No 142 142
656 77.35 Adjustabale Screw Spanner 12 Inches 424365 No 227 227
657 77.36 Box Spanners 424120 Set 2000 2000
658 77.37 Transil Oil Dielectric Breakdown Test Kit 440060 No 63000 63000
659 77.38 SF6 Gas Leak Detector 440830 No 31539 31539
660 77.39 DC Volt Meter Range - 3V to +5V 359180 No 450 450
661 77.40 Hydrometer syrings suitable for vent holes 422811 No 150 150
662 77.41 Specific Gravity Correction Chart 620172 No 150 150
663 77.42 Wall Mounting Type Holder for Hydrometer 430311 No 100 100
664 77.43 Earth Resistance Tester 359481 No 5400 5400
665 77.44 Rubber Appron 427341 No 185 185
666 77.45 Pippette 430140 No 350 350
667 77.46 Protective Goggle 427330 No 350 350
668 77.47 Acid Resisting jars (4 Pint capacity) 429814 No 375 375
669 77.48 Rain Coats with Hoods 427300 No 439 439
670 77.49 Rubber Shoes Knee Height 427360 No 504 504
671 77.50 Glass Funnel 430200 No 105 105
672 77.51 Hickery Rods 427120 No 957 957
Mtr
673 77.52 Manilla Rope 1" 406226 2200 2200
(100)
Mtr
674 77.53 Manilla Rope 3/4" 406220 1800 1800
(100)
675 77.54 Polypropyline Rope of 26mm dia 406351 Kg 211 211
676 77.55 Files of sizes 426000 Set 250 250
677 77.56 Safety Belts 427320 No 610 610
678 77.57 Safety Belts with Accessories Set New Item
679 77.58 Safety Helmets 427310 No 112 112
Electrical Safety (FRP) Helmets attached with
680 77.59 427311 811 811
electronic induction tester (FRP)
Hand Operated Crimping tool 25 Sqmm to 400
681 77.60 425320 No 7870 7870
Sqmm
682 77.61 Common Meter Reading Instrument 358361 No 25925 25925
683 77.62 Thermal Imaging Camera 440661 No 357000 357000
Hydraulic Crimping Tool with suitable Dies for
684 77.63 425360 Set 9500 9500
crimping lugs of size upto 400Sqmm
685 77.64 Hi Visibility Reflective Jackets 407301 No 672 672
686 77.65 Hi Visibility Reflective Rain Wear 407302 No 2939
Protective Eye Wear for Safety with integral hands
687 77.66 407303 No 847
free LED Lighting
688 77.67 Leather Shoes 407304 Pair 933 Will be intimated
689 77.68 Socks 407305 Pair 90
690 77.69 Safety shoes with socks Pair New Item
691 77.70 Waist Leather Belt 407306 No 469
Chain saw (Motorised), extremely robust and long
lasting chain saw. Highly suitably for cutting
692 77.71 414371 Set 24793 24793
firewood, thinning shrubs and bushes and
shaping trees.
693 77.72 FRP wall extension ladder 427075 Set New Item

694 77.73 Search Lights (Hand Held & Fixable to Vehicle) 427440 No Will be Intimated Will be Intimated

695 77.74 LDPE Safety Cone with ESCOMs Logo 407370 No Will be Intimated Will be Intimated
HM HDPE Flexible Poly Film Barricade Tape of 50
696 77.75 Microns with ESCOMs Logo, Caution, Danger & 407375 Mtr Will be Intimated Will be Intimated
Men At Work

697 77.76 Men at work Sign Board 407380 No Will be Intimated Will be Intimated

698 77.77 Insulated Crowbars 404065 No Will be Intimated Will be Intimated

699 77.78 Helmet with Miner Light 427312 No Will be Intimated Will be Intimated

700 77.79 Foldable Insulated Fibre Ladder 427076 No Will be Intimated Will be Intimated

701 77.80 Head Torch 427447 No Will be Intimated Will be Intimated

Insulated GOS Operating Handle/Rod for


702 77.81 503215 No 1900 1900
Redesigned & Modified GOS
78 Miscellaneous Materials
Per
703 78.01 Cable Covering Tiles 125x250x40 mm 801035 10000 10000
1000
Per
704 78.02 Cable Covering Tiles 125x125x40 mm 801034 5000 5000
1000
705 78.03 RCC Hume Pipes 2000mm long 150mm dia 820672 No 300 300
706 78.04 RCC Hume Pipes 2000mm long 200mm dia 820673 No 380 380
707 78.05 Collars for RCC hume pipe 150mm dia 820703 No 80 80
708 78.06 Collars for RCC hume pipe 200mm dia 820704 No 100 100
709 78.07 MS Pipe 200mm dia with collars 765050 Mtr 937 937
710 78.08 Burnt Bricks (class 35 modular) 802005 No 5 6
711 78.09 Wire cut bricks (Class 75 Modular) 802006 No 10 13

712 78.10 Pre - cast hollow blocks (40x20x20 cms) grade 30 802007 No 26 38

713 78.11 River Sand 800650 Cmt 2000 1700


714 78.12 Artificial Sand/Manufacture Sand 800651 Cmt 950 1700
715 78.13 Cement in 50kg bags 800030 Bag 330 335
716 78.14 Ready Mix concrete M20 (1:1.5:3) 800660 Cmt 3450 4600
717 78.15 Ready Mix concrete M25 (1:1:2) 800661 Cmt 3850 4800
718 78.16 Spall (Jelly used for packing) 800662 Cmt 50 400
719 78.17 Stone Spalls 800663 Cmt 130 300
720 78.18 Stone Boulders 800664 Cmt 200 600
Route & Joint indicating stone with MS Anchor
721 78.19 802460 No 120 120
rod
Black Cambric tape 25 mm wide 10mil thick and
722 78.20 622675 Roll 120 120
in rolls of 50 Mtr
Yellow Cambric tape 25 mm wide 7mil thick and
723 78.21 622620 Roll 110 110
in rolls of 50 Mtr
PVC Insulation Tapes19 mm wide and in rolls of
724 78.22 622720 Roll 10 10
10 Mtrs
725 78.23 ACB Paint 632030 Ltr 120 132
726 78.24 Aluminium Paint 632013 Ltr 180 198
727 78.25 Grey Enamel Paint smoke/battle ship 632050 Ltr 250 250
728 78.26 Red Oxide Paint 632020 Ltr 90 99

729 78.27 Cotton Tapes 19 mm wide and in rolls of 50 Mtrs 622124 Roll 35 35

730 78.28 Cotton Waste 627520 Kg 50 50


731 78.29 Hack saw blade 300x12.5 mm 418185 No 7 7
TW plate 300x300x25 mmwith 20mm dia holes at
732 78.30 the corners and coated with two coats of varnish 612621 No 230 230
on one side/SMC board.
TW Meter Board, 300x300x75mm, coated with
733 78.31 612623 No 110 110
varnish/SMC board
100
734 78.32 Monoplast 506559 55 55
Gms
735 78.33 Bitumen Compound 604060 Kg 65 65
79 Copper Control cables 1.1 kV Class
736 79.01 2 Core, 2.5 Sqmm 289352 Km 42486 60000
737 79.02 4 Core, 2.5 Sqmm 289354 Km 74211 85342
738 79.03 10 Core, 2.5 Sqmm 289360 Km 161561 193000
739 79.04 14 Core, 2.5 Sqmm 289364 Km 234500 267646
740 79.05 19 Core, 2.5 Sqmm 289369 Km 313615 360657
741 79.06 2 Core, 4 Sqmm Km New Item 82000
742 79.07 2 Core, 6 Sqmm 289452 Km 92508 103999
743 79.08 2 Core, 10 Sqmm 289472 Km 117438 135054
744 79.09 4 Core, 4 Sqmm 289404 Km 152675 175576
745 79.10 4 Core, 6 Sqmm 289454 Km 153608 169999
746 79.11 4 Core, 10 Sqmm 289474 Km 248481 285752
747 79.12 4 Core, 16 Sqmm 289484 Km 367781 422948
748 79.13 Flurocent Light Fitting 446024 No 255 255
749 79.14 Flurocent tube 611530 No 40 40
T-5 Tubelight fitting Complete 28 watts with tube -
750 79.15 446040 No 440 440
4 feet
751 79.16 Floracent Lamp for above 446037 No 102 102
T-5 Tubelight Fitting Complete 14 watts with tube
752 79.17 446038 No 425 425
- 2 feet
753 79.18 Floracent Lamp for above 611730 No 90 90
754 79.19 Sodium Vapour Lamp (250W) 612645 No 650 650
755 79.20 Automatic Switches for Street Lights 446044 No 1850 1850
756 79.21 GI Bracket for Flurocent Tube 612240 No 300 300
278832/2
757 79.22 Sodium Vapour lamp Ignitors No 225 225
78811
758 79.23 Caution/Danger Board 613050 No 120 120
759 79.24 Standard Torch Cell 1.5V 612660 No 11 11

760 79.25 Street light metering box made of MS sheet steel 358012 No 1913 1913

761 79.26 Street light metering box made of SMC 1700 1700
80 Compact Fluorescent Lamps
762 80.01 5 Watts 611545 No 100 100
763 80.02 8 Watts 611548 No 104 104
764 80.03 11 Watts 611551 No 120 120
765 80.04 14 Watts 611554 No 116 116
766 80.05 18 Watts 611558 No 148 148
767 80.06 23 Watts 611563 No 168 168
81 Bolts & Nuts
MS
768 81.01 B & N Size 16x40mm 733612 MT 74102 63000
769 81.02 B & N Size 16x50mm 733613 MT 74102 63000
770 81.03 B & N Size 16x65mm 733616 MT 74102 63000
771 81.04 B & N Size 16x75mm 733618 MT 74102 63000
772 81.05 B & N Size 16x85mm 733620 MT 74102 63000
773 81.06 B & N Size 16x100mm 733623 MT 74102 63000
774 81.07 B & N Size 16x125mm 733625 MT 74102 63000
775 81.08 B & N Size 16x150mm 733628 MT 74102 63000
776 81.09 B & N Size 16x175mm 733630 MT 74102 63000
777 81.10 B & N Size 16x200mm 733633 MT 74102 63000
778 81.11 B & N Size 16x225mm 733634 MT 74102 63000
GI
779 81.12 B & N Size 16x40mm 280612 MT 90102 85000
780 81.13 B & N Size 16x50mm 280613 MT 90102 85000
781 81.14 B & N Size 16x65mm 280616 MT 90102 85000
782 81.15 B & N Size 16x75mm 280618 MT 90102 85000
783 81.16 B & N Size 16x85mm 280620 MT 90102 85000
784 81.17 B & N Size 16x100mm 280623 MT 90102 85000
785 81.18 B & N Size 16x125mm 280625 MT 90102 85000
786 81.19 B & N Size 16x150mm 280628 MT 90102 85000
787 81.20 B & N Size 16x175mm 280630 MT 90102 85000
788 81.21 B & N Size 16x200mm 280633 MT 90102 85000
789 81.22 B & N Size 16x225mm 280634 MT 90102 85000
LT Brass Terminal Connector for
82 Transformer (630 Amps, Aprrox.
Weight 0.790kg)
780 82.01 250 kVA 542180 No 822 822
781 82.02 500 kVA 542185 No 822 822
83 Brass Cable Glands
782 83.01 25mm 542190 No 62 62
783 83.02 32mm 542192 No 75 75
784 83.03 40mm 542194 No 117 117
785 83.04 45mm 542196 No 156 156
LT Capacitor 3 Ph Housed in a encloser
with necessary fusses, wiring,
84
mounting arrangement as per tech
Spec
786 84.01 3 kVAr 333103 Set 525 725
787 84.02 9 kVAr 333109 Set 931 1131
788 84.03 18 kVAr 333118 Set 1733 1933
789 84.04 27 kVAr 333127 Set 2758 2958
790 84.05 54 kVAr 333154 Set 4883 5083

FOR DISTRIBUTION TRANSFORMER


CENTRES MS Box for housing the ETV
Meter 3 phase 4 wire 5A, with
85 associated LT CTs class 0.5 accuracy,
ring type, with wiring clamps, B&N and
all other accessories required.
(EXCLUDING ETV METER)
With CT Ratio 50/5 for 15/25kVA Distribution
791 85.01 358055 Set 5845 5662
Transformer Centre
With CT Ratio 100/5 for 50/63kVA Distribution
792 85.02 358060 Set 5362 5224
Transformer Centre
With CT Ratio 150/5 for 100kVA Distribution
793 85.03 358065 Set 5023 4918
Transformer Centre
With CT Ratio 400/5 for 250kVA Distribution
794 85.04 358070 Set 5200 5080
Transformer Centre
With CT Ratio 800/5 for 500kVA Distribution
795 85.05 358075 Set 5350 5215
Transformer Centre
SMC metering box as above
With CT Ratio 50/5 for 15/25kVA Distribution
796 85.06 358056 Set 6390 5662
Transformer Centre
With CT Ratio 100/5 for 50/63kVA Distribution
797 85.07 358061 Set 5907 5224
Transformer Centre
With CT Ratio 150/5 for 100kVA Distribution
798 85.08 358066 Set 5568 4918
Transformer Centre
With CT Ratio 400/5 for 250kVA Distribution
799 85.09 358071 Set 5745 5080
Transformer Centre
With CT Ratio 800/5 for 500kVA Distribution
800 85.10 358077 Set 5895 5215
Transformer Centre
Installing RLMU for the Existing
86
Distribution Transformer Center
Providing RLM Unit with necessary wiring for
housing PLC, MCCB, MCB, Energy Meter, CTs,
801 86.01 358086 No 10752 10752
Cotactors etc., as per specification in Metallic
Enclousure
Programmable Logic Controllers with
802 86.02 358098 Set 19339 19339
communication ports
803 86.03 GSM Modem 447662 No 7642 7642
MCCB
804 86.04 For 25 kVA, 40/60 Amps 358088 No 1485 1485
805 86.05 For 63 kVA, 100 Amps 358090 No 1500 1500
806 86.06 For 100 kVA,160 Amps 358092 No 1700 1700
807 86.07 For 100 kVA, 250 Amps 358093 No 5486 5486
808 86.08 For 250 kVA, 400 Amps 358095 No 9752 9752
809 86.09 For 500 kVA, 630 Amps 358096 No 16450 16450
810 86.10 MCB 6 Amps 358094 No 210 210
Contactors
811 86.11 For 25 kVA, 40 Amps 352440 No 2010 2010
812 86.12 For 63 kVA, 100 Amps 352460 No 3280 3280
813 86.13 For 100 kVA, 160 Amps 352480 No 5775 5775
814 86.14 For 100 kVA, 225 Amps 352485 No 11390 11390
Compact Pre - fabricated Packaged Sub -
87
station 11kV/433 V

Packaged Sub - Station 11kv/433V


consisting of 3 way SF6/VCB insulated
compact RMU, oil cooled/dry type copper
wound transformer and L.T. section with
one ACB as incoming and 7 No outgoing
MCCB feeders and with encloser made of
electronically Galvanized

815 87.01 With 100 kVA Oil Cooled Transformer 276530 No 1132904
816 87.02 With 250 kVA Oil Cooled Transformer 276540 No 1491923
817 87.03 With 500 kVA Oil Cooled Transformer 276550 No 2009325
818 87.04 With 750 kVA Oil Cooled Transformer 276575 No 2415622
819 87.05 With 990 kVA Oil Cooled Transformer 276590 No 2821919
Will be intimated
820 87.06 With 100 kVA Dry Type Transformer 276531 No 1182768
821 87.07 With 250 kVA Dry Type Transformer 276541 No 1611596
822 87.08 With 500 kVA Dry Type Transformer 276560 No 2212473
823 87.09 With 750 kVA Dry Type Transformer 276585 No 2711112
824 87.10 With 990 kVA Dry Type Transformer 276599 No 3191280
87.11 Breakup prices
Copper wound Oil Cooled Distribution
Transformer
825 87.12 500 kVA 321450 No 805743
826 87.13 750 kVA 321475 No 997537
827 87.14 990 kVA 321490 No 1331175
Will be intimated
828 87.15 LT ACB 2000A 310520 No 115716
829 87.16 MCCB 400A 358097 No 14100
85 SCRAP MATERIALS
Note: The rates are indicative and the
respective zones are authorized to fix the floor
price suitabaly as approved in the Common SR
2012-13 meeting held on 09.11.2012 and
confirmed vide proceedings CEE/T&P/KPTCL -
6998 - 7013 Dt: 15.11.2012
830 85.01 Copper Wire 791210 Kg 512 518
Released Copper winding released from failed
831 85.02 731211 Kg 192 192
distribution transformers
832 85.03 Copper Conductor 791200 Kg 512 518
833 85.04 Copper Ingots 791205 Kg 358 358
834 85.05 Copper Cable with Leads 791207 Kg 248 248
835 85.06 Aluminium 791010 Kg 124 124
836 85.07 Aluminium wire in pieces 791100 Kg 85 88
837 85.08 ACSR Conductor in Rings/Coils New Item 100
Released Aluminium winding released from failed
838 85.09 791175 Kg 100 130
distribution transformers
839 85.10 Scrap HT/LT Aluminium Winding New Item 161
840 85.11 ACSR Conductor 791101 Kg 89 100
841 85.12 Alumininium UG cable 791531 Kg 103 103
842 85.13 Scrap Al Released From UG Cable 791530 Kg 88 88
Iron Items
843 85.14 a) SM Rail Pole, I beam 790100 Kg 20 32
844 85.15 b) Ladder Pole, Tower Parts, Tubular Poles 790101 Kg 20 18
845 85.16 c) Cross arms,Clamps etc 790104 Kg 20 20

846 85.17 d) Released steel from RCC Poles (Skeleton rods) 790103 Kg 20 20

847 85.18 e) Barbed/Ground wire/Zinc sheet etc 790102 Kg 20 20


848 85.19 Transformer Empty tanks of different capacity 790300 No Deleted NA
849 85.20 Transformer Empty tanks of different capacity 790300 Kg 18 17
850 85.21 Scrap GOS with Insulators 790401 Kg 25 25
851 85.22 Broken Steel Furniture 790402 Kg 26 26
852 85.23 Brass 791300 Kg 176 176
853 85.24 Baliga Poles 793510 Rmtr 72 72
854 85.25 Scrap Wooden Furniture 793501 Kg 16 16
855 85.26 Empty Barrel of 210 Litres Capacity - Good 442120 No 440 455
856 85.27 Empty Barrel of 210 Litres Capacity - Bad 795030 No 292 284
857 85.28 Lead 791400 Kg 80 80
HT Metering Cubicle, Distribution Boxes, Feeder
858 85.29 795240 Kg 20 18
Piller Boxes etc
859 85.30 Energy Meters (Electro Mech) Single Phase 795910 Kg 46 75
860 85.31 Energy Meters (Electro Mech) 3 Phase 795920 Kg 46 75
861 85.32 Single/3 Phase Electronic Meters 795925 Kg 51 75
862 85.33 CTs & PTs 795500 Kg 67 67
Scrap Distribution Transformer of
Aluminium Winding (without oil)
863 85.34 15 kVA 795102 Each 4754 4757
864 85.35 25 kVA 795104 Each 5857 5857
865 85.36 63 kVA 795106 Each 8570 8681
866 85.37 100 kVA 795110 Each 12052 15539
867 85.38 200 kVA 795120 Each 27500 27500
868 85.39 250 kVA 795125 Each 28600 37524
869 85.40 300 kVA 795130 Each 30250 30250
870 85.41 500 kVA 795150 Each 36575 36575
Scrap Distribution Transformer of
Copper Winding ( without oil)
871 85.42 15 kVA 795101 Each 9740 9740
872 85.43 25 kVA 795164 Each 26066 26066
873 85.44 50 kVA 795165 Each 25126 25126
874 85.45 63 kVA 795166 Each 35000 35000
875 85.46 100 kVA 795170 Each 45402 45402
876 85.47 200 kVA 795180 Each 76004 76004
877 85.48 250 kVA 795182 Each 85000 85000
878 85.49 300 kVA 795190 Each 91767 91767
879 85.50 500 kVA 795195 Each 152393 152393
880 85.51 5 MVA 795198 Each 915000 915000
Scrap CSP 11kV Distribution
Transformer
881 85.52 15 kVA 795157 Each 9736 9736
882 85.53 25 kVA 795158 Each 6000 6000
883 85.54 63 kVA 795160 Each 10000 10000
Scrap Wooden Reels
884 85.55 In good condition 793504 Kg 14 14
Empty Wooden Reel Deteriorated and with iron
885 85.56 793550 No 77 77
Rods
886 85.57 Scrap Aluminium Lead Wire
Scrap RMU with/without breaker(rusted &
887 85.58 Ton NEW ITEM 43165
borken panles)MEI Make

Scrap RMU with/without breaker(rusted &


888 85.59 Ton NEW ITEM 22000
borken panles)MEI Make
LABOUR RATES FOR COMMON SR 2016-17 for 11 kV SYSTEM
Common Common
Sl
Item No Particulars Unit SR 2014- SR 2016-
No
15 in Rs 17 in Rs
1 1 Digging of Pits
Digging of Pits 1.8 mtr depth for errection of 9 to 10
2 1.1 mtr Long Steel/RCC/PSC supports as per approved
Drawing.
3 1.1.1 Ordinary Soil Per pit 334 378
4 1.1.2 Hard Soil Per pit 1145 1294
5 1.1.3 Hard latterite Soil Per pit 1270 1435
6 1.1.4 Hard Rock (By Chizling and/Or Wedging) Per pit 2172 2454
Digging of Pits 1.5 mtr depth for erection of 7.5/8
7 1.2 mtr Long Steel/RCC/PSC/PCC supports as per
approved Drawing.
8 1.2.1 Ordinary Soil Per pit 269 304
9 1.2.2 Hard Soil Per pit 926 1046
10 1.2.3 Hard latterite Soil Per pit 1025 1158
11 1.2.4 Hard Rock Per pit 1751 1979
Digging of Pits 2.0 mtr depth for errection of 9.5mtr
12 1.3 Long RCC supports (350Kg Working load for 33KV)
as per approved Drawing.
13 1.3.1 Ordinary Soil Per pit 366 413
14 1.3.2 Hard Soil Per pit 1159 1310
15 1.3.3 Hard latterite Soil Per pit 1379 1558
16 1.3.4 Hard Rock Per pit 2378 2688
Digging of Pits 2.2 mtr depth for errection of 11mtr
17 1.4
Long RCC/PSC supports as per approved Drawing.

18 1.4.1 Ordinary Soil Per pit 410 464


19 1.4.2 Hard Soil Per pit 1554 1756
20 1.4.3 Hard latterite Soil Per pit 1554 1756
21 1.4.4 Hard Rock Per pit 2668 3015
Digging of Pit 2.5 mtr depth for errection of 11mtr
22 1.5
long tubular spun pole as per approved Drawing.

23 1.5.1 Ordinary Soil Per pit 1007 1137


24 1.5.2 Hard Soil Per pit 2013 2275
25 1.5.3 Hard latterite Soil Per pit 2013 2275
26 1.5.4 Hard Rock Per pit 6542 7393
Digging of pit. For providing GI Pipe type
1.6
Earthing

27 1.6.1 Ordinary Soil Per pit 404 457


28 1.6.2 Hard Soil Per pit 1586 1792
29 1.6.3 Hard latterite Soil Per pit 1757 1986
30 1.6.4 Hard Rock Per pit 2627 2968
1.7 Digging of Pit for GUY SET
31 1.7.1 Ordinary Soil Per pit 173 195
32 1.7.2 Hard Soil Per pit 441 499
33 1.7.3 Hard latterite Soil Per pit 487 550
34 1.7.4 Hard Rock Per pit 1124 1270
Note: For Hard Latterite Soil and Hard Rock Soil
works have to be classified and certified by
35
Executive Engineer, where ever these types of soil is
encountered.
Concrete works
Providing cement conccrete to poles and Guy sets
1.8
36 with material and labour including necessary curing
etc., complete (cost does not include excavation)
A) Base concrteing with CC 1:4: 8
a) Pole base for 11/9.5/9/8 mt supports
37 Each 194 229
(500x650x150mm)
1.8.1 b) Pole based for 9mtrs square pole
38 Each 252 298
(650x650x150mm)
39 c) Pole base 11mtr spun pole (1000x1000x150mm) Each 596 704

B) Pole concreting with CC 1:2:4 (without coping)

40 a) 9mtrs support (650x500x1700mm) Each 2185 2566


41 b) 9.5 mtrs support (650x500x1850mm) Each 2373 2792
42 c) 11 mtrs PSC support (650x500x2000mm) Each 2312 2721
1.8.2
43 d) 9 mtrs Square pole (650x650x1700 mm) Each 2731 3214
44 e) 11 mtrs Spun pole (1000x1000x2500mm) Each 9668 11378
45 f) 8mtrs support (400x400x1500mm) Each 835 982
g) Guy concreting with Boulders, Mud & Sand As per
46 Drawing No. BESCOM/GM/CP/7/dt: 24.10.07. Each 140 158
(with out cement)
C) providing coping for pole with CC 1:2:4 (As per
actuals)

a) 150mm around poles for a height of 300mm for


47 1.8.3 Each 403 444
RCC, PSC, PCC poles/I-beam/Rail steel sections
b) 390mm all around the pole for an height of
48 Each 906 1040
300mm for Spun poles
D) Guy concreting in Marshy area
1.8.4 a) Providing cement concrete 1:2:4 for Anchor Rod in
49 Each 798 824
Marshy/Black Cotton Soil 600x600x450mm

2 Erection of Poles
Erection of steel supports 9.0 to 10.00 mtr long such
as 22.68 kg (50 lbs) Rail, 27.22 kg (60 Lbs) Rail I
Beam of sizes 200x100mm, 175x90 mm, 125x100
50 2.1 No 269 304
mm. Fabricates poles tubular poles in pits of 1.8 mtr
Depth, Aligning, Refilling with soil and ramming as
approved drawing
Same as above but erection of 7.5 to 8.0 mtr long
51 2.2 steel supports (18.75 kgs., /41Lbs) Rail, 125x75 No 240 271
mm, I beam in pit of 1.5 mtr depth.
Same as above but erection of RCC/PCC/PSC poles
52 2.3 No 482 544
of 7.5 to 8 mtr long in pit of 1.5 mtr depth.
Erection of RCC/PSCC poles 9 to 10 mtr long but in
53 2.4 No 603 682
a pit of 1.8 mtr depth
Erection of RCC poles 9.5 mtr long 350Kg WL but in
54 2.5 No 850 960
a pit of 2.0 mtr depth for 33KV lines
Erection of 11 mtr PSC pole with working load of
55 2.6 No 963 1088
365kg in a pit of 2.2 mtrs depth.
Erection of 11mtr long Concrete spun pole in a pit of
56 2.7 No 1077 1216
2.5 mtr depth.(Manual Labour)

Erection of 11mtr long Concrete spun pole in a pit of


57 2.8 No New Item 1500
2.5 mtr depth.(Mechnised Labour)

Releasing and Replacing Insulators

58 2.9 11KV Pin Insulators No 25 28


59 2.10 11KV Dead End Insulators Disc, Strain etc No 30 34
Erection of 2 pole structure formed out of SM rails
or I -Beam of sizes 200x100 175x90 mm,
225x100mm of 9 to 10 mtr long in pits of 1.8 mtr
60 2.11 Per structure 1686 1906
depth for line deviation with necessary foundation,
inclusive of fixing of cross Arms, Braces, Strain
Insulators.

61 2.12 Same as above using RCC poles 9 mtr to 10 mtr long Per structure 2209 2496
Same as above using RCC poles 7.5/8 mtr long in
62 2.13 Per structure 2209 2496
pits of 1.5 mtr depth.
providing spiral earth electrode type earthing along
63 2.14 No 49 55
with pole (without charcoal, salt etc.,)
64 2.15 Errection of H Frame. No 169 191
Erection of Double pole transformers structure
including fixing of structural materials, erection of
65 2.16 poles etc., complete for mounting of transformers as Per structure 2216 2504
per approved drawing using I-Beems or MS Rail 8
mtrs. long.
2.17 Same as item above with RCC pole 9/8 mtr. long.
Upto 63 kVA
66 2.18 with 9 mtrs. RCC pole Per structure 2973 3359
67 2.19 with 8 mtrs. RCC pole 2612 2952
100 to 250 kVA
68 2.20 with 9 mtrs. RCC pole Per structure 3081 3482
69 2.21 with 8 mtrs. RCC pole 2839 3208
Above 250 kVA
70 2.22 with 9 mtrs. RCC pole Per structure 3405 3848
71 2.23 with 8 mtrs. RCC pole 3050 3447
Erection of single pole mounted Transformer
3
structures
for 250 kVA Transformer on the existing 11 mtrs.
72 3.1 Per structure 1799 2033
Spun pole (excluding erection of pole)
for 100 kVA on the existing 9 mtrs. RCC pole (Squre
73 3.2 Per structure 899 1016
Section) (excluding erection of pole)
for 25/63 kVA on the existing 9 mtrs. RCC pole
74 3.3 Per structure 899 1016
(Square Section) (excluding erection of pole)
For 25kVA transformer existing 9mtr PSCC Pole of
75 3.4 Per structure New Item 1575
300Kg WL.(excluding erection of pole)
3 Pole structure: Erection of 3 pole structure
formed with 3 Nos 9 mtr RCC Pole with platform for
mounting 100 to 500 kVA transformers as per
76 3.5 Per structure 4546 5137
approved Drawing including fixing structure
materials, erection of poles etc., complete. (excluding
excavation charges)
4 Pole Structure: Erection of 4 pole structure
formed with SM Rail or I Beam of size 200x100 mm
175x90 mm, 225x100 mm size, 9 to 10 mtr long in
77 3.6 Per structure 3753 4241
pits for line deviation with necessary foundation,
including fixing of cross arm, braces, strain/disc
insulators.
Erection of 4 Pole structure as in item above with
78 3.7 platform for mounting of Transformer. (excluding Per structure 4299
excavation charges)

Construction of platform with size stone,


cement concert for erection of 500 kVA
Transformer/Metering cubicle/Heavy Equipment.
Construction of platform (1.5x1.5x1.2) mtr in size
stone, for erection of transformers/Heavy equipment
including all materials, labour.
Excavation of (1.5x1.5x1) mt pit for foundation
providing and laying cement concrete 1:4:8 for
foundation laid in 10 cm thick layers, well
compacted curing etc., complete providing and
79 4 Per structure 17972 25192
construction of stone masonary 0.9m below ground
level and 1.2m above ground level neatly hammer
dressed in cement morter 1:6.Providing and Laying
cement concrete slab 1.5x1.5x0.10Mtr with cement
concrete of 1:2:4 mix forming & cutting complete,
providing pointing to stone masonary in cement
morter 1:3 after racking joint & nisely lining curing
etc., plastering the concrete surfaces in cement
morter 1:4 including smooth randering curing etc.,
curing at every stages completely.

Fixing of 2 Pin cross arm with insulator and Braces


80 4.1 Each 85 96
fixing
Fixing of 4 Pin cross arm with insulator and Braces
81 4.2 Each 85 96
fixing
Fixing of V-Shape/Horizontal cross arm including
82 4.3 Each 88 99
single top support Braces and Insulators fixing
Fixing of V-Shape/Horizontal cross arm for DC Line
83 4.4 including Braces and Insulators fixing. (Without Each 72 81
Single Top Support)
Fixing of 4 Pin double cross arm including braces
84 4.5 Set 148 168
and insulators.
85 4.6 Fixing of HT/LT single top support . Each 56 64
86 4.7 Fixing of Earth Guard Stirrup Set of 2 nos 88 99
5 Fixing of Anticlimbing Device
87 5.1 Spike Type per Set 20 23
88 5.2 GI Barbed Wire (12 mtrs/1kg) No 23 25
a) Fixing of GUY Sets with break insulators making
use of 7/3.15 mm (7/10 SWG) galvanised steel wire
89 per Set 141 159
with turn buckle and anchoring arrangement as per
5.3 approved drawing. (Excluding excavation of PIT)

b) Same as above but using 2 strain insulators


90 per Set 158 179
(No.15)

Fixing guarding including fixing of necessary cross


91 5.4 arms for existing HT and LT line at Road Crossing, per Set 533 603
Telephone Line Crossings up to span of 60 mtrs.

Fixing guarding including fixing of necessary cross


92 5.5 arms between HT and LT line up to a span of 40 mtrs per Set 533 603

93 5.6 Above 40 Mtrs. Span per Set 938 1059


94 5.7 Fixing of Danger Board Unit 43 48
Stringing of conductor wren, squirrel, weasel,
binding of conductor on each insulator and dead
95 5.8 per km/wire 1693 1913
ending on strain or disc/strain insulator by means
of clamps.
96 5.9 do - for Rabbit ACSR per km/wire 2308 2608

97 5.10 do - for Coyote ACSR per km/wire 4031 4555

6 Rates for LT Reconductoring Works

98 6.1 Stringing of conductor (including pin binding,


providing jumps, dead ending, etc.,)

99 6.2 Weasel per km/wire 2296


New Item
100 6.3 Rabbit per km/wire 3130

101 6.4 Coyote per km/wire 5466

102 6.5 Releasing of conductor

103 6.6 Weasel per km/wire 1722

New Item
104 6.7 Rabbit per km/wire 2347

105 6.8 Coyote per km/wire 4100


Releasing & Refixing of over head service mains
per
(single phase/3 phase) (While executing
106 6.9 connection 35 35
reconductoring works only) Per
main
connection/installation
Releasing & Refixing of over head service mains per
107 6.10 (single phase/3 phase) (While replacing existing pole) connection 53 53
main
NOTE:
1. Labour charges for releasing conductor is 90% of
108
the corresponding stringing rates for New Lines
2. Special Locality Allowance as applicable shall be
109
loaded to the labour charges
3. For new conductor required for LT
110
Reconductoring 3% sag is allowed
4. Quantity of returnable release conductor shall be
111 as per circular No: BESCOM/GM(T)/BC-20/F-
664/05-06/Cys-174 dtd:10.01.2006

112 5. HT Recondutoring works: Reconductring for the HT is to be followed on the stringing


rates for new conductor and releasing rates for old.
7 Erection of Transformer
a) Erection of 25 to 63 kVA Transformer on
113 7.1 Each 603 682
Transformer structure.
114 7.2 -do- 100 kVA Transformer Each 805 910
115 7.3 -do- 200-250 kVA Transformer Each 1208 1365
116 7.4 -do- 300-500 kVA Transformer Each 1610 1819
Providing GI Pipe Earthing for lightning arresters per Set of 1
117 7.5 Transformer Neutral and Transformer Metal parts no. of 103 116
(Excluding digging of pits) electrode

Hiring of crane for erection of 250/500 kVA


Transformer (applicable for maintenance works
118 7.6 Per TFR 4025 2500
only and in case of non -availability of departmental
crane)

Hiring of crane for releasing existing Transformer


and erection of NEW 250 to 500kVA Transformers.
119 7.7 No 4200 2500
(applicable for maintenance works only and in case
of non -availability of departmental crane)

Hiring of crane for releasing existing Transformer


and erection of NEW 250 to 500kVA Transformers.
120 7.8 In case of failure and agumentation, (applicable for No 4200 2500
maintenance works only and in case of non -
availability of departmental crane)

NOTE:- When the awards are issued for erection of New


121 Transformers under labour awards, Hire charges are not payable for
cranes hired. By the agencies.
8 HT Metering

122 8.1 Erection of HT metering Cubicle on Platform. No 1208 1364

Erection of LT Feeder piller box including


necessary civil works like soil excavation &
concreting etc. complete
123 8.2 upto 8 ways No 875 989
124 8.3 above 8 ways No 946 1069
9 Distribution Box for DTCs
Fixing LT Distribution box for 100/250/500 KVA
125 9.1 Per box 403 455
DTCs (Excluding wiring)
10 Additional cost for making termination using H/Wedge Clamps
126 10.1 Rabbit to Rabbit No 64 72
127 10.2 Coyote to Coyote No 85 96
128 10.3 Rabbit to Coyote No 85 96
Additional cost for making termination using H-
129 10.4 Clamps along with 2 hole Paddle/In-Line Set 175 198
Connector/Micro wedge connector.
Fixing Metering Box for housing the ETV Meter 3-ph 4 wire along
11
with CT's, Meter & wiring for DTC's
130 11.1 25/63 kVA TC per Set 1014 1145
131 11.2 100 kVA TC per Set 1014 1145
132 11.3 250 kVA TC per Set 1014 1145
133 11.4 300/500 kVA TC per Set 1014 1145
Fixing 3-phase LT Capacitor housed in a enclosure with necessary
12
Fuses, wiring, mounting arrangement for

134 12.1 per Set 338 382


15/25 kVA DTC, 3 kVAr
135 12.2 63 kVA DTC, 9 kVAr per Set 338 382
136 12.3 100 kVA DTC, 18 kVAr per Set 398 450
137 12.4 250 kVA DTC, 27 kVAr per Set 465 525
138 12.5 500 kVA DTC, 54 kVAr per Set 486 549
Erection & Commmissioning of 11kV Auto reclosures and
13
Sectionalizers with remote communication capability
Erection of fabricated steel structure for Seating
139 13.1 per Set 350 396
Auto reclosures and Sectionalizers
Erection of 11kV Auto reclosures with control box
GSM modem, connecting cable, control transformer,
140 13.2 per Set 2450 2769
wiring testing and commissioning including
parameterisation
Erection of 11kV sectionalizers with control box
141 13.3 GSM modem, connecting cable, PTs wiring testing per Set 2100 2373
and commissioning including parameterisation

14 Installing RLM Unit for the existing Distribution TC including wiring


142 14.1 for 25 kVA per Set 3083 3483
143 14.2 for 63 kVA per Set 3083 3483
144 14.3 for 100 kVA per Set 3083 3483
Fixing DOLO cutouts/Horn Gap Fuses including
145 14.4 Each 125 141
fixing of cross arms and wiring
146 14.5 Fixing of GOS including wiring (11kV SB 200A) Set 563 636

147 14.6 Fixing of GOS including wiring (11kV DB 400A) 625 706
Fixing of 11KV GOS SB or DB including wiring on
148 14.7 old existing structure (were only fixing of GOS work 1250 1413
is involved)
Modification of GOS Operating System for making
Foot path free for pedestrian(Work involves cutting
149 14.8 Per GOS 1979 1979
of existing vertical GOS Pipe and fixing the cuppling
plate by welding, grinding etc., for operating the GOS
150 14.9 Fixing of 3 Nos lightning arrestors including wiring. Set/3 No's 63 71
151 14.10 Fixing Pole Fuse Board No 76 86
Fixing PVC pipe for taking the leads form the
conductor to the pole fuse board (including taking
152 14.11 the lead wire inside the PVC pipe & giving Set 116 131
connection to the overhead line & pole fuse
box/Aerial fuse Board).
153 14.12 Fixing of LT Line spacers No 36 41
Releasing & Refixing of over head service mains
Per
(single phase/three phase) for consumer installation
154 14.13 connection/ 35 40
and street lighting and similar work (While executing
installation
reconductoring work)

Releasing & Refixing of over head service mains


Per
(single phase/three phase) for consumer installation
155 14.14 connection/ 53 59
and street lighting and similar work (While replacing
installation
existing pole)
15 Supplying and fixing conduit
Supplying heavy guage PVC pipe 25mm dia 2mm
thick confirming to IS 2509 with suitable size bends,
junction box, adhesive paste etc and fixing using
inverted wood plug in case RCC ceiling & RCC Wall
156 15.1 Mtr 68 70
stone structure are rawal plugs in case of brick walls
and cement plastering damaged portion using heavy
gaauge saddles at an intervel of 700mm using NF
Screws (2/1)
Wiring for lighting/power circuit using one of FRLS
PVC insulted 1100 volts grade multi strand copper
with low conductor resistance 2.5Sq mm single core
157 15.2 Mtr 12 29.20
wire in open are concealed system of wiring with
specified IS-694-1990 and conform into GTP of
group A
Wiring for lighting/power circuit using one of FRLS
PVC insulted 1100 volts grade multi strand copper
with low conductor resistance 4Sq mm single core
158 15.3 Mtr 39 42.10
wire in open are concealed system of wiring with
specified IS-694-1990 and conform into GTP of
group A
Supplying and fixing of porcelain fuse channel with
cut out 16 Amps on existing wooden/panel using
159 15.4 No 69 120
necessary nuts, bolts, and washers etc complee
(32/3)
Fixing and Wiring of Single/Three Meter phase meter Per
160 15.5 90 90
on the existing meter board connection
Per
161 15.6 Releasing of Single/Three Phase Meter 60 60
connection
16 Street Light and Other Works
162 16.1 Fixing and Wiring Incandescent street Light Fitting Set 334 176
with two Clamps.
Fixing and Wiring of FTL with suitable clamps
bracket bolts and nuts using departmental material
163 16.2 Set 334 176
and departmental ladder vehicle under supervision
of departmental Staff.
Fixing and Wiring as SV/M.V light Fittins with
suitable clamps Brackets, lamps, Bolts and nuts
164 16.3 using departmental Materials and departmental Set 535 176
Lader vehicle under supervision of departmental
Staff.
Fixing of Mercury Vapour Lamp fitting/Ornamental
165 16.4 Set 393 393
Light Fitting with Control Boxes etc.,

166 16.5 Fixing of LT Protection Kit Per Kit 181 205


(a) Wiring of One circuit of LT Wiring for for
25/63/100 KVA DTC to the existing LT protection
167 16.6 Kit/Distribution Box via metering box. (includes Set 503 568
fixing of necessary supports like 2 Pin X-arms,
Spacers etc)
(b) Wiring of Two circuits of LT Wiring for for
25/63/100 KVA DTC to the existing LT protection
168 16.7 Kit/Distribution Box via metering box.(includes Set 805 910
fixing of necessary supports like 2 Pin X-arms,
Spacers etc)
Fixing One Circuit of LT Wiring for 250/500 KVA
169 16.8 Transformers via metering box. (includes fixing of Per Circuit 644 728
necessary supports like 2 Pin X-arms, Spacers etc)

Surveying for construction of HT and LT Lines duly


170 16.9 furnishing single line diagram indicating pole Km 500 565
locations
171 16.10 Numbering and Scheduling of poles Km 379 428
172 16.11 Magpying (Excluding Cost of paint etc.,) Km 150 170
90% of the 90% of the
pole pole
173 16.12 Dismanting of Steel/I- Beam No
erection erection
charges. charges.

85% of the 85% of the


8 Mtrs. RCC 8 Mtrs. RCC
174 16.13 Releasing of baliga pole No Pole Pole
erection erection
charges. charges.

17 Releasing & Restringing of loose spans, binding, straightening of

Tightening of loose spans 90% of the 90% of the


a) Weasel/Squirrel correspondin correspondi
175 17.1 Km
b) Rabbit g stringing ng stringing
c) Coyote charges. charges.

75% of the 75% of the


correspondin correspondi
176 17.2 Straightening of slant/bent poles No
g erection ng erection
charges. charges.

Note: Above works (3.53) has to be recorded in


register maintained at SO/SD/Division office.
Record has to be verified by the Executive
Engineer (Ele) before issuing approval for work
orders /awards.

177 17.3 Dismantling of 2 B&S to I/O copper or equivalent Km 664 750


178 17.4 Dismantling of copper conductor above 2 B&S. Km 1070 1209

90% of the 90% of the


correspondin correspondi
179 17.5 Any Dismantling work No
g erection ng erection
charges. charges.

18 Jungle Clearing: 3 mtrs corridor (1.5 mtrs on either side of line)


Trimming of trees and branches and clearing as
180
per IE Rules.
In Malnad/hilly areas if
181 18.1 Jungle/trees/Plants/Shrubs exists only (once in two Km 2715 3068
years)
182 18.2 In Maidan (In accordance with necessity) Km 958 1082
As above for construction of new line including
19 Trimming of Trees, if Jungle/Tree/Plant/Shrubs
Exists.
183 19.1 Malnad/Hill Area Km 4855 5486
184 19.2 Maidan Area Km 2901 3278

Cutting, Clearing of Vegetation Grass/shrubs


20.0 such other small plants, including removal of
Roots etc., in station yard/store yard.

185 20.1 Maidan Area (Twice in year) Sqmt 4 5


186 20.2 Malnad Area (Once in Three Months) Sqmt 4 5
21 Transportation Rates:
Transporation by Head Load where ever
there is no accessability for transporation by
vechicle
Poles: for Transporting one pole (Not payable for
187 21.1 No 123
distance less than 25 Mtrs)
Conductor: For Transporting 1 km Length
188 21.2 Conductor (Not payable for distance less than 25 per km 53
Mtrs)
Transformer: For Transportation 25 kVA See New
189 21.3 Transformer (Not payable for distance less than 25 No 263 item
Mtrs) furnished
Transformer: For Transportation 63 kVA below`
190 21.4 transformer (Not payable for distance less than 25 No 438
Mtrs)
Transformer: For Transportation 100 kVA
191 21.5 Transformer (Not payable for distance less than 25 No 438
Mtrs)
22 Poles
192 22.1 Upto 25Mtrs included in the Rates NIL
193 22.2 25 to 105Mtrs per pole 170
New Item
194 22.3 105 to 185 Mtrs per pole 185
195 22.4 Above 185 Mtrs per pole 210

25 ACSR Conductor

196 25.1 Upto 25Mtrs included in the Rates NIL


197 25.2 25 to 105Mtrs per KM of 74
New Item
198 25.3 105 to 185 Mtrs conductor 81
199 25.4 Above 185 Mtrs 90
26 Distribution Transformer 25KVA

200 26.1 Upto 25Mtrs included in the Rates NIL


per
201 26.2 25 to 105Mtrs New Item 335
Transformer
202 26.3 105 to 185 Mtrs 415
203 26.4 Above 185 Mtrs 450
Distribution Transformer 63 KVA & 100KVA
204 26.5 Upto 25Mtrs included in the Rates NIL
205 26.6 25 to 105Mtrs per 550
New Item
206 26.7 105 to 185 Mtrs Transformer 650
207 26.8 Above 185 Mtrs 750
Hire Charges (These charges have to be
specifically approved by the Corporate Office
27
in respect of repair to transformers when
applicable)
Rs. 23 per Rs. 23 per
Kms Kms
subjected to subjected to
208 27.1 Transportation using 7.5/10 Tons Lorry Km a minimum a minimum
of Rs. of Rs.
1200/- per 1200/- per
day day

Rs. 17 per Rs. 17 per


Kms Kms
subjected to subjected to
209 27.2 Transportation using mini Lorry/Tempo Km a minimum a minimum
of Rs. of Rs.
1000/- per 1000/- per
day day

Loading of any type of material not covered


210 27.3 MT 1043 1178
specifically (cost includes crane charges if any).

UnLoading of any type of material not covered


211 27.4 MT 1043 1178
specifically (cost includes crane charges if any).

Loading of Power Transformer and other similar


212 27.5 materials like switchgear cable drums, Drake /Lynx, MT 1158 1308
conductors etc., (cost includes crane charges if any).

Unloading of Power Transformer and other similar


213 27.6 materials like switchgear cable drums, Drake/Lynx MT 1158 1308
conductors etc., (cost includes crane charges if any).
a) Loading and unloading of poles (loading of
poles to vehicles at stores and unloading at
28
workspot) NOTE:- Consolidated amount for
both loading and unloading.
214 28.1 8 mtr RCC/PSC poles No 56 63
215 28.2 9 mtr RCC/PSC poles No 75 84
216 28.3 8 mtr PCC pole No 47 53
a) Loading of Transformer(when maintaince men for loading and
29
unloading are not available in store)

217 29.1 25 kVA No 144 162


218 29.2 63 kVA No 144 162
219 29.3 100 kVA No 216 244
220 29.4 250/300 kVA No 360 407
221 29.5 500 kVA No 719 812
b) Un loading of Transformer
222 29.6 25 kVA No 144 162
223 29.7 63 kVA No 144 162
224 29.8 100 kVA No 216 244
225 29.9 250/300 kVA No 360 407
226 29.10 500 kVA No 719 812
Fixing of energy meter to non-metered IP sets 10HP and below:
30 Including cost of all the materials like Meter Board, Channel cutouts
and necessary wires required for the work.
Fixing Single phase Energy meter to IP Sets fixed
227 31.1 Per IP Set 693 783
inside Pump House
Fixing 3 ph Energy meter to IP Sets fixed in Pump
228 31.2 Per IP Set 958 1082
House
Fixing of Energy meters to IP sets, (where there is no
pumphouse) where power supply is availed directly
229 31.3 Per IP Set 3201 3617
from the pole to the IP set and weather proof meter
housing box is required (including cost of WP box).
32 UG Cable Works
Earth work excavation for cable trench of 0.5 to 0.75
mtr. Width and Depth upto 1 mtr. including trial
pits, depositing on bank upto a lead of 50 mtrs,
230 32.1
Supplying and Displaying necessary Danger Boards
and Lighting, Using sight Rails and Sign Boards at
every 100mtrs wherever necessary as directed.

231 32.2 In Ordinary Soil Cmt 181 205

232 32.3 In Hard Soil Cmt 271 307


233 32.4 In Ordinary Rock without Blasting Cmt 241 273
234 32.5 In Ordinary Rock with Blasting Cmt 396 448
235 32.6 Hard Rock/Latterite Rock latterite Soil Cmt 976 1103
Note: *Soil classification has to be certified by the
concerned Executive Engineer Elc.

20% over & above may be given if depth is more


than 1 m
Refilling the cable trenches with selected available
earth from trench excavation including watering,
236 32.7 consolidation in layers of 15 cm. Thickness Cmt 40 45
including depositing of the surplus earth with a lead
of 200 Mtrs.
Cutting of Road surface for cable trenches and
disposing of the excavated earth, as directed
237 32.8
including Barricading, Danger Lighting then Refilling
the Cable Trenches.
238 32.9 Macadam Road Cmt 228 257
239 32.10 Tar Road Cmt 375 424
240 32.11 Cement Concrete Road Cmt 754 852
Removing the Existing Stone Slabs pavement and
stocking the materials for excavating the trench with
241 32.12 Sqmt 101 114
a lead of 50 mtr Refixing the stone slab after refilling
the trenches as in item 2

Laying and Jointing the pipes (100-150 mm), dia


242 32.13 including lowering in Position: Fixing Collars etc.,
Joining with mud mortor complete
243 32.14 RCC Pipe Mtr 35 40
244 32.15 Stone Ware Pipe Mtr 28 31
Laying the GI Pipe 80mm to 150 mm dia at Drainage
Water Supply Crossing including fixing collars
245 32.16 Mtr 40 45
elbows, bends, Tees and other fitting with Cuts and
Threads wherever necessary complete.

Removing and Refixing stone Masonary with


necessary patch up and cementing drain works for
246 32.17 Cmt 525 593
Cluvert, Water Valve Crossing etc., including cost of
materials.
247 32.18 Covering cable with Tiles Km 2304 2603
Spreading and forming with sand all round the cable
248 32.19 to a depth of 75 mm and width of 500 mm. (Does not Km 8094 9146
include cost of sand).
Removing the kerb Stones and Refixing at the
249 32.20 Rmtr 8 8
original place with necessary earthwork
250 32.21 Fixing of Route Joint indicating Slabs No 60 68

Transporting HT cable from Store to work spot


33 including loading and unloading (including Crane
and other equipment charges if any)

per Km of
251 33.1 3x95 to 150 Sqmm 10120 11436
cable
per Km of
252 33.2 3x185 to 3x240 Sqmm 12145 13724
cable
per Km of
253 33.3 1x300 to 1x1000 Sqmm (Single Core) 12145 13724
cable
per Km of
254 33.4 3x300 to 3x500 Sqmm 14168 16009
cable
-do- for LT Cables
per Km of
255 33.5 2.5 to 25 Sqmm (Single Core, 4 Core, 3.5 Core) 625 706
cable
per Km of
256 33.6 35 to 95 Sqmm (4 Core/3.5 Core) 1250 1413
cable
per Km of
257 33.7 120 to 240 Sqmm (4 Core/3.5 Core) 1375 1554
cable
Laying of cable in Existing trench/GI pipe/Stone Ware/RCC Hume
34
pipe using Wooden/Aluminum Rollers as directed by the
HT Cable
258 34.1 3x95 to 150 Sqmm Km 31679 35797
259 34.2 3x185 to 240 Sqmm Km 33439 37786
260 34.3 1x1000 Sqmm Km 33439 37786
261 34.4 3x300 to 3x500 Sqmm Km 35198 39774
35 LT Cable
262 35.1 2.5 to 25 Sqmm Km 11304 12774
263 35.2 35 to 95 Sqmm Km 16543 18694
264 35.3 120 to 240 Sqmm Km 16893 19089
36 Cable Joint and wiring(for HT Cable only)
36.1 Epoxy straight through joint
265 36.2 3x95 to 3x150 Sqmm No 875 989
266 36.3 3x185 to 3x240 Sqmm No 875 989
267 36.4 3x300 to 3x400 Sqmm No 875 989
37 Heat shrinkable straight through joint
268 37.1 3x95 to 3x150 Sqmm No 1500 1695
269 37.2 3x185 to 3x240 Sqmm No 1500 1695
270 37.3 3x300 to 3x400 Sqmm No 1500 1695
38 Making and Fixing pot head for HT Cable only
Epoxy type
271 38.1 3x95 to 3x150 Sqmm No 875 989
272 38.2 3x185 to 3x240 Sqmm No 875 989
273 38.3 3x300 to 3x400 Sqmm No 875 989
39 Heat shrinkable type
274 39.1 3x95 to 3x150 Sqmm No 1375 1554
275 39.2 3x185 to 3x240 Sqmm No 1375 1554
276 39.3 3x300 to 3x400 Sqmm No 1375 1554
Releasing of HT cable after excavation refilling,
277 39.4 Km 31678 35796
consolidation Rewinding to the drum etc.,
278 39.5 -do- for LT cable Km 10884 12299
Earth Excavation for R.M.U. Foundation Depositing of earth on Bank
40
up to a lead of 50 mtr and with a lift up to 1.5 mtr
279 40.1 Ordinary Soil Cmt 141 178

280 40.2 In hard soil Cmt 211 267

281 40.3 In ordinary/soft Rock without Blasting Cmt 270 831


282 40.4 In ordinary/soft Rock with Blasting Cmt 289 475
Hard Rock/Lattirite Rock/Lattirite Soft (Chistling &
283 40.5 Cmt 941 1192
Wedging)
Note: Soil classifications has to be decided by
respective Executive Engineer

KSRB 2-4 Refilling the RMU foundation with the


approved new earth with initial lead of 50 mtr
284 40.6 Cmt 56 72
including watering and tamping layers of 15 cm
thick etc., complete.

285 40.7 Lifting of Excess Earth up to distance of 10 km Cmt 206 233

KSRB 4-1.3: Providing and Laying in position plain


cement cocrente of mix M7.5 (1:4:8) with OPC
Cement @ 180 Kgs, with 40mm and down size
graded granite metal coarse aggregates @ 0.85 cum
and fine aggregtes @ 0.57 cum machine mixed,
286 40.8 Cmt 3973 4695
machine mixed, concrete laid in layers not exceeding
15 cms. thick well compacted, in foundation and
plinth, including cost of all materials, labour, HOM
of machinery, curing complete as per specifications.
SPECIFICATION No. KBS 4.1, 4.2

KSRB 4-1.6: Providing and Laying in position plain


cement cocrente of mix M15 (1:2:4) with Cement @
240 Kgs, with 20mm and down size graded granite
metal coarse aggregates @ 0.878 cum and fine
aggregtes @ 0.459 cum machine mixed concrete laid
287 40.9 Cmt 4425 5084
in layers not exceeding 15 cms. thick well
compacted, in foundation and plinth and cills,
including cost of all materials, labour, HOM of
machinery, curing complete as per specifications.
SPECIFICATION No. KBS 4.1, 4.2
KSRB 4.9.1: Providing mild steel reinforcement for
RCC work including straightening, cutting, bending,
hooking, placing in position, lapping and /or welding
wherever required, and Laying with binding wire and
288 41 anchoring to the adjoining members wherever Quintal 6830 6008
necessary complete as per design (laps, hooks and
wastage shall not be measured and paid)cost of
materials labour, HOM of machinery complete as per
specifications. SPECIFICATION No. KBS 4.6.3

KSRB 5.2-3: Providing and constructing


granite/trap/basalt size stone masonry in foundtaio
with cement mortar 1:6 edges of stones chistle
289 41.1 dressed in courses not less than 15 cms high, bond Cmt 3776 3829
stones at two m. apart in each course including cost
of materials, labour curing complete as per
specifications. KBS 5.1.13

KSRB 5.2-3: Providing and constructing


granite/trap/basalt size stone masonry in
foundation cement mortar 1:8 stones hammered
290 41.2 dressed in courses not less than 20 cms high, bond Cmt 3287 3689
stones at two m. apart in each course including cost
of materials, labour curing complete as per
specifications. KSB 5.1.13

KSRB 5-8.5: Providing quoin dressing to stone


masonry and stone slabs, two line 5 Cms wide on
291 41.3 Mtr 68 86
each face as per specifications. (measurement
including mortar joints) KSB 5.1.13

KSRB 15-3.11Plastering concrete surface in cement


292 41.4 mortar 1:4, 20 mm thick inclusive of smooth Sqmt 188 222
rendering curing etc., complete.

KSRB 6-2.2 Providing and constructing Burnt Brick


Masonary with approved quality of Non-modular
bricks of standard size of class designation 50 (table
293 41.5 moulded) with cement mortar 1:8 for basement and Cmt 5189 6141
superstructure including cost of materials, labour
charges, scaffolding, curing complete as per
specifications. Specification No. KBS 6.2

1. Transporting RMU (Coventional) unit from


store to work spot including loading, unloading.
(No separate crane charges)

295 41.6 5 panels No 11338 12811


296 41.7 1 panel No 2268 2562
1. Transporting RMU (Compact) unit from store
to work spot including loading, unloading. (No
separate crane charges)

297 41.8 5 panels per set 6000 6780

298 41.9 3 panel per set 4000 4520


2. Fixing foundation frame of channels and angle
iron welding fixing in concrete aligning the RMU
on foundation bed, assembly of units, connecting
Bus Bars from panel to panel initial filling of oil
etc., complete.

299 41.10 5 panels No 12553 14184


300 41.11 1 panel No 2510 2836
Lettering the RMU with enamel paint and also
writing single line diagram of each panel, caution
301 42 per panel 528 596
Board, Danger Board etc., including cost of Paint,
Brush etc.,
302 43 Cleaning of Bitumen type pothead bus joint (All sizes) No 835 944
Breaking and cleaning of straight through joint (All
303 44 No 835 944
sizes)
Sealing of cable ends including supply of
45
plumbing lead, plumbing materials.

304 45.1 PILC No 808 912


305 45 XLPE No 150 170
LABOUR for Aerial Bunched Conductor &
46
Accessories
Item Description
Stringing of 11kV grade aerial bunched 3 core cable
306 46.1 of XLPE insulation of size 3x95 Sqmm+1x70 Sqmm Km 18076 20426
with bare/insulated messenger wire

Stringing of 11kV grade aerial bunched 3 core cable


307 46.2 of XLPE insulation of size 3x120 Sqmm+1x95 Sqmm Km 18076 20426
with bare/insulated messenger wire

Stringing of 1.1kV grade aerial bunched 3 core cable


of XLPE insulation of size (3x95) (for Phase
308 46.3 Km 13441 20426
conductor) + (1x70) (insulated messenger neutral) +
(1x16) street light control.
Stringing of 1.1kV grade aerial bunched 3 core cable
of XLPE insulation of size (3x95) (for Phase
309 46.4 Km 13441 20426
conductor) + (1x70) (insulated messenger neutral) +
(1x25) for street light control.
Stringing of 1.1kV grade aerial bunched 3 core cable
of XLPE insulation of size (3x95) (for Phase
310 46.5 Km 13441 20426
conductor) + (1x70) (insulated messenger neutral) +
(1x35) for street light control.
Erection of Suspension Clamp - 25 to 95 sqmm bare
311 46.6 No 102 115
messenger
Erection of Anchor Clamp - 25 to 95 Sq. mm bare
312 46.7 No 102 115
messenger
Erection of Suspension Clamp - 25 to 95 sqmm
313 46.8 No 136 154
insulated messenger with bracket
Erection of Anchor Clamp - 25 to 95 Sq. mm
314 46.9 No 136 154
insulated messenger with bracket
315 46.10 Fixing of Universal Hook No 102 115

316 46.11 Pole Clamp-145mm x 95 No 170 192


Installation of Insulation piercing connector for main
317 46.12 to street light No 48 54
Main : 16-95sqmm, Tap : 1.5-10sqmm(EP95)
Installation of Insulation piercing connector for main
318 46.13 to service line No 68 77
Main : 16-95sqmm, Tap : 4-35sqmm(P2X95)
Installation of Insulation piercing connector for main
319 46.14 to service line No 68 77
Main : 25-95sqmm, Tap : 25-95sqmm(P3X95)

Installation of Insulation piercing connector for main


320 46.15 to service line No 68 77
Main : 50-150sqmm, Tap : 4-35sqmm(P4X150D)

Installation of Pre-insulated straight thru' joints-


321 46.16 No 136 154
MJPT for 16 Sqmm cable
Installation of Pre-insulated straight thru' joints-
322 46.17 No 136 154
MJPT for 25 Sqmm cable
Installation of Pre-insulated straight thru' joints-
323 46.18 No 136 154
MJPT for 50 Sqmm cable
Installation of Pre-insulated straight thru' joints-
324 46.19 No 136 154
MJPT for 70 Sqmm cable
Installation of Pre-insulated straight thru' joints-
325 46.20 No 170 192
MJPT for 120 Sqmm cable
326 46.21 Installation of Pre-insulated lugs-CPTAU for 16 Sqmm No 136 154

327 46.22 Installation of Pre-insulated lugs-CPTAU for 25 Sqmm No 136 154

328 46.23 Installation of Pre-insulated lugs-CPTAU for 50 Sqmm No 136 154

329 46.24 Installation of Pre-insulated lugs-CPTAU for 70 Sqmm No 136 154


Installation of Pre-insulated lugs-CPTAU for 95
330 46.25 No 142 160
Sqmm
Installation of Pre-insulated lugs-CPTAU for 120
331 46.26 No 176 199
Sqmm
Distribution box suitable for 20 single phase
332 46.27 No 340 384
connections
333 46.28 Distribution box suitable for 6 3 phase connections No 476 538

334 46.29 T-connector KZ3 95 No 115 130

335 46.30 End cap for 50/70 Sqmm No 4 5

336 46.31 11kV AB Cable T-joint installation for 3 Core No's 916 1035
11kV AB Cable Straight thru' joint installation for 3
337 46.32 No's 733 828
Core
338 46.33 11kV AB Cable Termination installation for 3 Core No's 620 700

339 46.34 Surge Arrester for ABC No 95 107

340 46.35 Ground connection for messenger wire No 23 26

341 46.39 Anchor sleeve for messenger wire No 4 5


Laying of UG Cables by trenchless technology by adopting horizontal
47
boring & Drawing of cable including preparation at site
342 Without HDPE Pipe
343 47.1 i) Normal soil 5'' bore size Rmtr 625 706
344 47.2 ii) Rock soil 5'' bore size Rmtr 1088 1229
345 47.3 iii) Normal soil 6" bore size Rmtr 625 706
346 47.4 iv) Rock soil 6" bore size Rmtr 1088 1229
347 47.5 v) Normal soil 8'' bore size Rmtr Deleted Deleted
348 47.6 vi) Rock soil 8'' bore size Rmtr Deleted Deleted
48 With HDPE Pipe
349 48.1 i) Normal soil 5'' bore size Rmtr 750 848
350 48.2 ii) Rock soil 5'' bore size Rmtr 1213 1370
351 48.3 iii) Normal soil 6'' bore size Rmtr 913 1031
352 48.4 iv) Rock soil 6'' bore size Rmtr 1425 1610
353 48.5 v) Normal soil 8'' bore size Rmtr Deleted Deleted
354 48.6 vi) Rock soil 8'' bore size Rmtr Deleted Deleted

Providing chain link fencing 50mm size of 8 guage


properly stretched between rectangular poles and
fixed with suitable bolts & nuts, the free ends shall
be welded to the pole and block pipe at top and
bottom as required including cost of all materials,
355 49 Sqmt 780 780
labour, lead and lifts, cutting, bending wherever
necessary, wastage and lapping etc., complete as per
the direction of the engineer incharge for work
including two coats of approved quality paint over
one coat of primer paint.

LTFP box Painting (including scrubbing of old paint,


supplying and applying primer and two coats of
356 50 LS 1294 1462
aluminium /enamel paint including minor repair to
box)
Spun Pole Painting (supplying and applying two
coats of enamel paints to 11Mtrs spun pole) and
357 51 Pole 5555 6277
painting all the metal parts of the structure with two
coats of aluminium paint over primer

Spun Pole Painting (supplying & applying two coats


358 52 Pole 2381 2690
of enamel paints to 11Mtrs spun pole) and painting

Repairing the broken damaged door of RMU with


359 53 necessary hinges, welding etc., with necessary paint per door 571 646
touch up including supply of paint for touch up.

Repairing the broken damaged door of LT feeder box


with necessary hinges, welding etc.with necessary
360 54 per box 381 431
paint touch up including supply of paint for touch
up.

Repairing the broken damaged door of LT


distribution box fixed to DTC with necessary hinges,
361 55 per box 286 323
welding etc. with necessary paint touch up including
supply of paint for touch up.

56 Erection of Compact Pre-fabricated Packaged Sub-station 11kV/433 V


Installing & fixing the compact pre-fabricated
packaged sub-station 100/250/500/750/990 kVA
transformer on the existing concrete plinth.(This
362 56.1 Set 8467 9568
does not include the cost of plinth, cable duct, laying
& termination of cable etc. provision for the same
shall be made)
Labour Charges towards Station Works (As per
Prevailing KPTCL SR with effect from 01.09.06)

57 11KV SWITCHGEAR
Erection, alignment and fixing to the foundation,
indoor/outdoor 11KV switchgear panel/unit
363 57.1
including movement from the point of unloading to
thr point of erction.
364 57.2 11KV Indoor/outdoor switchgear 1839 2078
Per Panel
365 57.3 11KV Kiosk 1530 1729
Wiring & assisting in testing &
58
Commissioning
366 58.1 11KV indoor/outdoor switchgear 610 689
367 58.2 11KV Kiosk 610 689
59 a) Wiring b)Testing & Commissioning
Identification of wires, Ferruling Crimping &
368 59.1 Termination of wires fir annunciation, etc., Testing
of Relays, CTs, PTs, & Breaker for operation.

For indoor /outdoor panel comprising of 2I


369 59.2 Per Set 69753 65503
+8F+1BC+1AP3

370 59.3 For single 11KV panel indoor/outdoor type /kiosk Each 13950 13098
371 59.4 For additional 11KV panel (indoor type) Each 6975 6544
372 59.5 For single 11KV panel outdoor type/Kiosk Each 10661 10009
Consolidated labour charges involving 1 to 2 (ONE to
373 60 TWO) pole works for Ganga Kalyana and Drinking Set 7813 8829
Water supply works only.

Consolidated labour charges involving 3 to 5 (THREE


374 61 to FIVE) pole works for Ganga Kalyana and Drinking Set 12344 13949
Water supply works only.

Consolidated labour charges for works 1 to 4


(ONE to FOUR) poles including excavation of pit,
pole erection, fixing of cross arms, stringing of
62 conductor, fixing of conductor accessories, fixing
guy sets, fixing of anti climbing device, spiral
earth electrode, danger board etc if any
(Applicable for both HT & LT Line)

375 62.1 For work involing 1 pole Set 3750 4238

376 62.2 For work involing 2 pole Set 5000 5650

377 62.3 For work involing 3 pole Set 6250 7063

378 62.4 For work involing 4 pole Set 7500 8475


Estimates Estimates
are to be are to be
379 62.5 For work involing 5 & above pole works Set
prepared as prepared as
per SR per SR

Consolidated Labour charges for shifting of the


conductor terminations(existing cut points) in
deteriorated existing poles to new poles erected.
380 63 Work includes all works associated with shifting of per pole New Item Rs.3000/-
the terminations, like shifting of aerial fuse boards,
cut outs, service main(UG cable and over head) and
any other existing fitting.

Consolidated Labour charges for shifting of the


existing conductor, including all works associated
with shifting of the conductor such as any fittings,
381 64 per pole New Item Rs.2200/-
aerial fuse boards, cut outs, service main (UG cable
and over head) etc., on the existing deteriorated
intermediate pole to new pole erected.

NOTE:

The loading and unloading charges shall be included at the following rates in all estimates for
1
the works which are proposed to be taken up on labour contract.

2 For Poles - As per the rates provided for Loading and unloading of poles in the SR

For all other materials excluding transformers and conductors - 10% of the rates
3
provisioned for Loading and unloading of poles in the estimate.

4 For Transformers and Conductor - As per the rates provided in the S.R.

The Labour charges for erection of Poles, Guy Sets, DP Structures etc., involving excavation of
soil provided in the cost sheet for general works is for ordinary soil only. Wherever other type of
5
soil is encountered, the difference in rates for excavation in such soil provided in the Schedule
of labour shall be worked out and adopted.

Special labour charges for Ganga Kalyna and Water Works, Drinking Water Works
and SC & E&I Works: (These rates are Applicable for works carried out under
6
labour awards only. THESE RATES SHALL NOT BE OPERATED FOR RATE
CONTRACT AWRADS AND OTHER TENDERED AWARDS).

Note:-
(1) These labour charges are applicable for 1 to 2 pole and 3 to 5 poles in respect of
Ganga Kalyana and Water Works

(2) These rates are applicable only when 1 to 2 pole and 3 to 5 poles are involved and no
other associated works.
(3) These rates are applicable only when 1 to 4 pole works for Service Main and E&I Works

The Labour charges are all inclusive i.e., digging of pits, erretion of poles, fixing of cross
arms, insulators, stringing of wires, providing of guy sets, fixing of spiral earthrodes, Etc.,

No other labour charges or any other charges towards special locality allowance, LC
charges, additional labour charges, Transportation charges, etc., are payable.

(4) Certificate has to be furnished by the section officer who prepares the estimate that
the estimates are not split to claim the above labour charges.

Labour Charges for one to two pole and three to five pole works in respect of all types of
works wherein other works such as DTC erection etc., and other works are not involved.
Schedule of Rate for Standard Stock Materials
Common SR 2016-17 (33kV System) Common Common
SR 2014- SR 2016-
15 17
in Rs in Rs
Sl Item Material FORD FORD
Name of the Material UoM
No No Code Rates Rates
inclusive inclusive
of duties of duties
taxes & taxes &
F&I F&I
33/11 kV Transformer with all fittings and
1 accessories, OLTC, RTCC, First filling of oil No.
and 10 % Spare oil
1 1.1 5 MVA No. 322205 4557570 3865685

Will be
intimated
by
2 1.2 10 MVA No. 322210 10267860
independe
nt
committee

3 1.3 12.5MVA 6659932


2 Circuit Breakers

4 2.1 33 kV Circuit Breaker SF6 type 800A, 25kA No. 311601 349540 306000

3 11kV Switch Gear


11KV 500MVA (1600A, for two incomer & two
capacitor bank and 1250A for eight feeders)
indoor type switchgear comprising
5 3.1 Set 7616045 7367300
2IC+10F+1BC+2AP VCB's all of 25KA
repturing capacity as per technical
specification

11KV 500MVA (1600A, for one incomer & one


capacitor bank and 1250A for four feeders)
6 3.2 indoor type switchgear comprising Set 4020640 3889300
1IC+5F+1BC+1AP VCB's all of 25KA repturing
capacity as per technical specification

11 kV, 500 MVA, (1600A, for incomer & 1250


7 3.3 A for feeder) outdoor Switch gear, comprising Set 309204 8466226 8189700
of 2I+1BC+12 f + 1 AP3 VCBs
11 kV, 500 MVA, (1600A, for incomer & 1250
8 3.4 A for feedder) outdoor Switch gear, comprising Set 309202 7371572 7130800
of 2I+1BC+10 f + 1 AP3 VCBs
11 KV, 500 MVA, 1250 A, (I/C) and 800 A
9 3.5 (feeder), outdoor Switch Gear, comprising of Set 309200 6204295 6001700
21+1BC+8F+1AP3 VCBs
11 kV Switch gear, 350 MVA, 800 Amps
10 3.6 Outdoor MCVCB comprising of 1 I + 5 f + 1 Set 309206 3393560 3282700
AP3
11 KV 500 MVA 1250 Amps 25 KA feeder
11 3.7 No. 309208 565355 551000
panel
11 KV 500 MVA 1250 Amps SWG
12 3.8 Set 309210 3451053 3338400
11+5F+1AP3 MCVCB
4 11kV Kiosk

11 kV 350 MVA, 800A Outdoor Type, kiosk


13 4.1 Set 309214 2151078 2080800
comprising of 1 I + 4 f + 1 AP3 PCVCB

11 kV, 350 MVA, 800A Outdoor type, kiosk


14 4.2 No. 309218 317530 308500
PCVCB
1I/C+4F+1AP, PCVCB to 33KV Kv Kaginele
15 4.3 sets NEW ITEM 2307515
Station
1I/C+3F+1AP, PCVCB to 33KV Kv Mallur
16 4.4 sets NEW ITEM 1921908
Station
17 4.5 2I/C+6F+1AP, PCVCB sets NEW ITEM 3789748

18 4.6 2I/C+8F+1AP to 33 KV I/E station sets NEW ITEM 4566276

11kV, 500 MVA, Outdoor type Switchgear with


21C+8F+2CB+1BC+1AP provided with VCB's,
19 4.7 1600A for incomer & capacitor Bank, 1250 A sets NEW ITEM 8431730
for outgoing feeders, all of 25 KA rupturing
capacity as per technical specification and
SCADA compatible
Procurment of PCVCBs to Batkal
20 4.8 sets NEW ITEM 2309181
Station(1I/C+4F+1AP)
Procurement of PCVCBs to 33/11 KV station
21 4.9 sets NEW ITEM 3760310
Kahanagaon Belagaum
5 Instrument Transformers
5.1 Current Transformers
22 5.1.1 220kV CT's No. 298147 302250
220kV class 1200-800-600-400-300/1-1-1-1-
23 5.1.2 No. 256000
1
110 kV 0.2 class accuracy CT with all
accessiories for metering purpose
24 5.1.3 a. CT ratio 100-75-1A No. 113861 115430
25 5.1.4 b. CT ratio 100-50-75-5A No. 114606 116180

26 5.1.5 c. CT ratio 100-5A No. 113864 115430


33 kV class CT With 0.2 accuracy class 400 -
27 5.1.6 No. 336470 28721 29120
200/1-1A for lines
33 kV class CT With 0.2 accuracy class 200 -
28 5.1.7 No. 336473 28721 29120
100/1-1-1A for Transformer
29 5.1.8 33 kV class CT 30/5A No. 336400 17956 18200

30 5.1.10 33 KV Oudoor CT's 400/200/1-1 No. 35136 35620

31 5.1.11 33 KV Oudoor CT's 200/100/1-1 No. 35136 35620

32 5.1.12 11 KV Oudoor CT's 800/400/1-1-1 No. 29704 30110

33 5.1.13 11 KV Oudoor CT's 600/300/1-1-1 No. 26734 27100

34 5.1.14 11 KV Oudoor CT's 400/200/1-1-1 No. 27848 28230

35 5.1.15 11 KV Oudoor CT's 200/100/1-1 No. 23392 23710


11kV NCTs 800-400/1-1-1A (for 350 MVA
36 5.1.16 No. 330210 17956 30000
SWG)
37 5.1.17 11kV NCTs 600-300/1-1-1A (for PCVCBs) No. 330220 17956 43000
6 Potential Transformers
38 6.1 220kV PT's No 672122 681370

39 6.1.1 220kV /√-3/110V/√.3-110V/√3-110V No 224000


110 KV 0.2 class accuracy PT with all
40 6.1.2 Nos. 151568 98000
accessiories for metering purpose
33kV Voltage Transformer 33kV √3 110√3-
41 6.1.3 No. 335512 38335 34000
110√3
42 6.1.4 33 KV Oudoor PT's No.
11kV Voltage Transformer 11kV / 110V-
43 6.1.5 No. 335220 8607 8730
110V(3 phase)
44 6.1.6 11 KV Oudoor PT's No

7 Lightning Arrester
a) 30 kV Lightning Arrester Normal Duty
45 7.1 No. 303510 12225 9000
Metal oxide (Discharge Class-2)
b) 30 kV Lightning Arrester Normal Duty
46 7.2 No. 303512 8784 7970
Metal oxide (Discharge Class-3)
30 kV Lightning Arrester Normal Duty
47 7.3 No. 303520 11096 10950
polymeric
8 Isolators
Isolators 33kV 800A, 25kA Upright with
48 8.1 Earth Switch complete metallic portion with Set 304536 78367 78000
insulator
Isolators 33kV 800A, 25kA Upright without
49 8.2 Earth Switch complete metallic portion with Set 304524 72978 59000
insulator (live point height 3750mm)

Isolators 33kV 800A, 25kA Upright without


50 8.3 Earth Switch complete metallic portion with Set 304525 78388 80000
insulator (live point height 4750mm)

9 Battery Set/Battery Charger


51 9.1 Battery Set (Tubular) 48 V, 100 Ah Set 344007 75600 136956

52 9.2 Battery Set (Tubular) 110 V, 100 Ah Set 344011 165600 300000
Battery Set (Maintance free VRLA) 48 V, 100
53 9.3 Set 344107 38400 69565
Ah
Battery Set (Maintance free VRLA) 110 V,100
54 9.4 Set 344111 82800 15000
Ah
55 9.5 Battery Charger 48 V, 100 Ah Set 344416 42135 58854

Battery Charger 110V, 100 Ah (with float cum


boost charger working on 230V 1ph AC
56 9.6 Set 344426 78750 110000
supply along with integral DCDB consisting 4
nos. O/G feeders as per specifications)

Capacitor Bank with 0.2% Series reactor &


57 9.7 NCT 12.1kV 2.5 MVAr star connected Set 333424 403200 403200
Capacitor Bank
10 Panel
58 10.1 33 kV Line Panel (Simplex) No. 339500 402800 326000

59 10.2 33/11kV Transformer Panel (Simplex) No. 339530 584000 472631

60 10.3 33 kV Capacitor Bank Panel No. 339540 321900 260513

11 Towers
a) Design,fabrication,galvansing and supply of
61 11.1 transmission line tower materials including M.T. 201050 102614 94000
stubs
b) Fabrication,galvanization and supply of
62 11.2 M.T. 201055 87203 85000
mild steel tower materials
63 11.3 c) Supply of galvanised Bolts & Nuts M.T. 736002 102614 119000

64 11.4 d) Supply of stub templates M.T. 210080 102614 89336


Outdoor type meter box to house ETV
12 meters, made of CRCA steel mounted on
angle iron frame work
65 12.1 Meter box suitable for fixing 6 ETV meters No. 358046 14371 14371
66 12.2 Meter box suitable for fixing 4 ETV meters No. 358044 8784 8784

67 12.3 Meter box suitable for fixing 3 ETV meters No. 358043 6149 6149

13 Insulators
68 13.4 Solid Core Insulator 33kV No. 283125 3253 3149

69 13.2 33 kV Pin Insulator (Shell only) No. 283006 437 520

70 13.3 33 kV Pin Insulator (Pin only) No. 283056 162 208

71 13.4 33kV Composit Disc Insulator No. 283433 728 704

72 13.5 33kV Polymer Pin Insulator New Item 962


33kV 70 KL Polymer Insulator (Ball & socket
73 13.6 New Item 585
type)
HARDWARE CLAMPS FOR STATION
14
MATERIALS
14.1 Bolted Type Tension Clamp

74 14.1.1 Single Lynx ACSR conductor 70/90 kN 16mm No. 285080 1015 963

Single Coyote ACSR conductor 70/90 kN


75 14.1.2 No. 285079 913 905
16mm
Single Rabbit ACSR conductor 70/90 kN
76 14.1.3 No. 285078 698 681
16mm
14.2 Bolted Type Suspension Clamp

77 14.2.1 Single Lynx ACSR conductor 70/90 kN 16mm No. 285050 799 860

Single Coyote ACSR conductor 70/90 kN


78 14.2.2 No. 258046 723 780
16mm
Single Rabbit ACSR conductor 70/90 kN
79 14.2.3 No. 285038 571 624
16mm
14.3 Ground Wire Clamp 7/3.15mm 2 bolt No. 281410 723 882

14.4 Post Insulator Clamp

80 14.4.1 Single Lynx ACSR conductor 127/76mm No. 285699 596 643

81 14.4.2 Single Coyote ACSR conductor 127/76mm No. 285697 545 595

82 14.4.3 Single Rabbit ACSR conductor 76mm No. 285696 507 445

14.5 "T" Clamp for ACSR Conductor

83 14.5.1 Single Lynx to Single Lynx No. 285610 343 366

84 14.5.2 Single Coyote to Single Coyote No. 285605 317 436


Terminal connector clamp for ACSR
14.6
Conductor
85 14.6.1 Single Lynx No. 282620 539 586

86 14.6.2 Single Coyote No. 282616 463 504


15 STATION STRUCTURES
Fabrication, galvanization and supply of
87 15.1 MT 276110 143591 125010
Station Structures
88 15.2 Supply of galvanized Bolts & Nuts MT 130648 113742

89 15.3 Double pole structure for 33kV Set 279103 5672 4931

90 15.4 V-Shape X arm for 33 kV No. 279016 846 736

91 15.5 HT ST Support for 33 kV No. 279093 353 307

92 15.6 Clamp 9.5M RCC Pole for 33kV No. 279526 93 81


33 kV 3 Core XLPE UG Insulated
16
Aluminium Cable
93 16.1 33 kV 3 Core XLPE UG Cable- 95 Sq.mm km 287451 2286860
Will be
94 16.2 33 kV 3 Core XLPE UG Cable- 150 Sq.mm km 287453 2689630 intimated
by
95 16.3 33 kV 3 Core XLPE UG Cable-240Sq.mm km 287456 2973570
independe
96 16.4 33 kV 3 Core XLPE UG Cable-300Sq.mm km 287457 3938710 nt
committee
97 16.5 33 kV 3 Core XLPE UG Cable-400Sq.mm km 287458 4553100
33kV Jointing and Cable termination kits
17
for XLPE cable
Heat Shrinkable type transition jointing
17.1
kit
98 17.1.1 33 kV 3 Core XLPE UG Cable- 95 Sq.mm No. 288050 23100 23100

99 17.1.2 33 kV 3 Core XLPE UG Cable- 150 Sq.mm No. 288052 23100 23100

100 17.1.3 33 kV 3 Core XLPE UG Cable-240Sq.mm No. 288054 34060 34060

101 17.1.4 33 kV 3 Core XLPE UG Cable-300Sq.mm No. 288055 34060 34060

102 17.1.5 33 kV 3 Core XLPE UG Cable-400Sq.mm No. 288056 39500 39500


Heat Shrinkable indoor type cable
17.2
termination kit
103 17.2.1 33 kV 3 Core XLPE UG Cable- 95 Sq.mm No. 288060 5840 5840

104 17.2.2 33 kV 3 Core XLPE UG Cable- 150 Sq.mm No. 288062 5840 5840

105 17.2.3 33 kV 3 Core XLPE UG Cable-240Sq.mm No. 288064 7990 7990

106 17.2.4 33 kV 3 Core XLPE UG Cable-300Sq.mm No. 288065 7990 7990

107 17.2.5 33 kV 3 Core XLPE UG Cable-400Sq.mm No. 288066 8740 8740


Heat Shrinkable outdoor type cable
17.3
termination kit
108 17.3.1 33 kV 3 Core XLPE UG Cable- 95 Sq.mm No. 288070 7255 7255

109 17.3.2 33 kV 3 Core XLPE UG Cable- 150 Sq.mm No. 288072 7255 7255

110 17.3.3 33 kV 3 Core XLPE UG Cable-240Sq.mm No. 288074 9030 9030

111 17.3.4 33 kV 3 Core XLPE UG Cable-300Sq.mm No. 288075 9030 9030


112 17.3.5 33 kV 3 Core XLPE UG Cable-400Sq.mm No. 288076 10730 10730

Heat Shrinkable Straight through jointing


17.4
kits with Aluminum lugs& ferrules

113 17.4.1 33 kV 3 Core XLPE UG Cable- 95 Sq.mm No. 288080 18920 18920

114 17.4.2 33 kV 3 Core XLPE UG Cable- 150 Sq.mm No. 288082 18920 18920

115 17.4.3 33 kV 3 Core XLPE UG Cable-240Sq.mm No. 288084 25320 25320

116 17.4.4 33 kV 3 Core XLPE UG Cable-300Sq.mm No. 288085 25320 25320

117 17.4.5 33 kV 3 Core XLPE UG Cable-400Sq.mm No. 288086 30160 30160


LABOUR RATES FOR COMMON SR 2016-17 for 33 kV SYSTEM
Common SR
Common SR
2016-17
2014-15
Sl Item in Rs FORD
Description Unit in Rs FORD Rates
No No Rates inclusive
inclusive of duties
of duties
taxes & F&I
taxes & F&I
1 Detailed Surveying on Turn-Key:

Reconnaissance Survey-cum-walk over Survey


along with Departmental Staff to determine the
feasible route of the line on topo sheet. An
1 alternate route if available should be indicated.
i) The route of the line is to be indicated and got
approved by the competent authority (Rates
include the cost of Toposheet and Transportation)

2 a) Hilly terrain km 795 898


3 b) Plain terrain km 773 873

Detailed Survey, fixing anchor points and taking


levels at 20 mtrs intervels drawing route profile
4 ii) on Graph paper indicating geographical features
like Nalas, Rivers, Gardens, P&T Lines, Railway-
crossings etc., and enroute villages.

5 a) Hilly terrain km 3934 4445


6 b) Plain terrain km 2626 2968
Fixing marking stones of size 200X200 x 1000
mm with approved marks including painting
above the ground level and Yellow Lettering and
marking the direction of incoming line and out
going lines are to be clearly marked on the top
7 iii) with red colour. If the distance between two Per Stone 391 442
anchor points is more than I km, one more
directional stone is to be fixed. So also for the
road crossing, railway crossing ,River crossing ,
HT crossing and nala crossing for all on both the
sides.

Burgie details for identification for all Anchor Per


8 iv) towers with existing permanent marks like poles, Anchor 354 400
telephone lines, buildings, etc., Tower

9 v) v) Conducting soil resistivity tests Per Test 678 766

Clearing of bushes, tree branches of trees


crops and shrubs wherever encountered for
vi) detailed survey to enroute the corridor width
of 3 mtrs (including viewing for fixing anchor
towers etc.,)
10 a) Hilly terrain KM 1174 1326
11 b) Plain terrain KM 784 886
a) Submission of reports in the form of good
binding including the preparation of sketches for
burgie details for each anchor points, scheduling
12 vii) Per set 239 270
of line details, S.R. values, soil classification
reports, tower schedule, abstract of towers etc.,
complete.
b) Drawing the route profile on graph sheet,
including geographic feature like Nalas, rivers,
13 viii) Per set 239 270
gardens, P&T lines railway crossing etc, inclusive
of all stationaries. (Normal requirement is 5 Sets)
xi) Preparing the Schedules:

PTCC Proposal : Containing PTCC questionaire,


topo sheet extracts with marking of the proposed
14 Set 946 1069
a) line, SR Report, tower sketch, station single line
diagram etc., (30 Copies/Sets)

Railway Crossing proposal with drawing are


Per
15 b) inclusive of graph sheets and other stationery 946 1069
crossing
materials, labour etc., (10 Sets)

Tree Schedule Containing the details like name of


tree, girth size of tree, distance from central line Per
16 c) 678 766
of the alignment, approximate height of the tree Hectare
etc., complete

Forest proposals: Inclusive of all works like


fixing of stones at every 20 mtrs in the centre line
and both ends of the corridor, painting of each
tree after chipping, writing the numbers on the
tree, taking girth size of all the trees coming in
d) Km 4411 4985
the corridor at 1 mtr height from GL, approximate
height of the tree and forest clearance proposals
etc., complete (10 Sets).
Note:
This applies to forest area only.
Check Survey by using their own
2
Equipment
17 a) Hilly terrain KM 2034 2298
18 b) Plain Terrain KM 1361 1538
3 Taking block levels for Sub-staitons:

Running Peripheral Theodolite traverse along


periphery and coordinating and heightening of all
corners/turning points, establishing permanent
co-ordinate axis formation of grids at 50m
19 intervals for northing and easting with reference Acre 1309 1479
a)
to already established permanent co-ordinate axis
levels at 50m grid intersection for preparing plot
plan of the entire area with contours. Including
existing structure location.

Establishing datum level and bench marks at


every 100m/50m intervals both longitudinal and
laterally and all corners/turning points with
20 b) No 1309 1479
stone pillars of size not less than 0.2mx2mx1.0m
buried on the ground and exposed top engraved
for painting RL, and coordinates of that point.

Taking level at 5M suitable grid interval in the


21 c) sub-station area for plotting block levels, contour No 29 32
map.
Preparation of CAD drawings, generating the
contours using appropriate software and
Per
22 d) submission of 6 sets of blue prints and one 13080 14780
Project
tracing sheet (original) and one soft copy etc.
Complete.

Furnishing cutting and filling quantities using Per


23 e) 3924 4434
appropriate software for earth work calculation. Project

Super imposing GA drawings on contour maps in


Co-ordination with departmental engineers and Per
24 f) 10463 11823
supply of 12 sets of blue print drawings etc., Project
complete.
4 Geo Technical Investigations:

Making 150mm nominal diameter bore holes at


various locations in soil using suitable approved
method of boring including, cleaning providing
Bore holes at interval and at change of strata,
collections of water samples, observation such as
ground water etc., Collection of undisturbed soild
25 a) samples at ever 2.0m/3.0m interval and at Mtrs 1958 2212
change of strata, transportation of all the
collected samples to the laboratory and back
filling of bore holes on completion of the work,
complete as per sepcification and instruction of
the engineers, for depths up to 6.0 m below
natural ground level or refusal strata.

Conducting various laboratory tests on soil


samples at approved laboratory including
preparation of soil samples for determination of
26 b) soil, Proparties etc., Complete as per
specification.
Note: Laboratory identified shall be approved by
ESCOM Engineers not below the rank of EE(Civil).

27 i) Bulk density and moisture content Each 784 886


28 ii) Sieve analysis Each 784 886
29 iii) Hydrometer Analysis Each 784 886
30 iv) Liquid limit and plastic limit Each 784 886
31 v) Shrinkage limits Each 916 1035
32 iv) Specific gravity Each 916 1035
33 vii) Standard proctor density test Each 916 1035
34 viii) Swell pressure Each 1050 1187
35 ix) Free swell index Each 1050 1187
36 x) Uncombined Compressive strength Each 1050 1187
37 xi) Triaxial shear test Each 1050 1187
38 xii) One dimensional consolidation test Each 1050 1187

39 xiii) California bearing ratio Each 1050 1187

Submitting final report in 6 copies including all


field records and laboratory test results, graphs
40 C) Per Job 15698 17738
and recommendations etc., complete as per
specifications.
Note: The above rates are inclusive of
mobilization of Plant Equipment & Materials for,
Topographical survey, block leveling and
41
Geotechnical investigation works, and
Demobilization. No extra rate is admisible for
mobilization & Demobilization
5 Excavation for station structure:
1) Corresponding 1) Corresponding
rates in KPWD SR rates in KPWD
as mentioned SR as mentioned
against each against each
classification classification
below shall be below shall be
adopted. adopted.

2) Area weightages 2) Area


applicable for the weightages
respective areas applicable for the
as per latest respective areas
KPWD SR shall be as per latest
allowed to arrive KPWD SR shall
at Final Rate. be allowed to
arrive at Final
3) Extra Rate.
for excavation
under water 3) Extra for
conditions and/or excavation under
Excavation of pits as per specifications for lattice foul conditions water conditions
type of station structures, Tr. Plinth, control including and/or foul
42 panels, mounting structures for breakers, CT's, bailing/pumping conditions
PT's Isolators, LA's etc., Excavation of trenches out, removing including
for control cables, U.G. Cables, Groundmat etc., slush add 20% of bailing/pumping
the rate of the out, removing
respective rate on slush add 20%
account of slow of the rate of the
progress of work respective rate
under these on account of
conditions. (The slow progress of
extra percentage work under
indicated here these conditions.
shall be as (The extra
indicated in the percentage
relevant KPWD SR) indicated here
shall be as
indicated in the
relevant KPWD
SR)

Latest KPWD SR
Latest KPWD SR
43 i) Normal Soil Cmt Rates for hard
Rates for hard soil
soil
Latest KPWD SR Latest KPWD SR
44 ii) B.C. Soil Cmt Rates for Ordinary Rates for
soil Ordinary soil
Latest KPWD SR Latest KPWD SR
45 iii) Partially Submerged soil Cmt Rates for Ordinary Rates for
soil Ordinary soil
Latest KPWD SR Latest KPWD SR
46 iv) Fully submerged soil Cmt Rates for Ordinary Rates for
soil Ordinary soil

Rate for ordinary Rate for ordinary


rock (Without rock (Without
47 v) Wet black cotton soil Cmt
blasting) of latest blasting) of latest
KPWD SR KPWD SR

Latest KPWD SR Latest KPWD SR


48 iv) Dry fissured/Ordinary rock Cmt Rates for Ordinary Rates for
soil Ordinary soil

Rate for ordinary Rate for ordinary


rock (Without rock (Without
49 vii) Latterite soil Cmt
blasting) of latest blasting) of latest
KPWD SR KPWD SR

Rate for ordinary Rate for ordinary


rock (With rock (With
50 viii) Hard rock with blasting/Hard latterite Cmt
blasting) of latest blasting) of latest
KPWD SR KPWD SR

Note 1: For Excavation purposes measurement


shall be as per actuals.
2: For foundation purposes predominant
soil shall be considered.
6 Excavation (For Tr. Line Tower)
51 i) Normal Soil Cmt
52 ii) B.C. Soil Cmt
53 iii) Partially Submerged soil Cmt Rates as per
Rates as per item
54 iv) Fully submerged soil Cmt item 5 + 50%
5 + 50% extra
55 v) Wet black cotton soil Cmt extra
56 vi) Dry fissured/Ordinary rock Cmt
57 vii) Latterite soil Cmt
58 viii) Hard rock with blasting/Hard latterite Cmt
7 Back Filling :
Rates as per Rates as per
Back filling with excavated earth available near KPWD SR KPWD SR
59 i) the tower and consolidation layer by layer of 150 Cmt applicable to applicable to
mm depth with adequate quantity of water. respective area respective area
+10% extra +10% extra

Rates as per Rates as per


Supplying and back filling with external hard KPWD SR KPWD SR
60 ii) murrum soil with proper consolidation including Cmt applicable to applicable to
lead and lift. repective area repective area
+10% extra +10% extra

Note: This item is applicable only when Black


cotton, soil, wet black cotton soil, dry fissured
rock, ordinary rock, Hard rock are encountered.

Concreting and curing (For Both


8
Transmission lines and station structures)
1) Corresponding
1) Corresponding
rates in latest
rates in latest
KPWD SR as
KPWD SR as
mentioned
Concreting & curing as per specifications mentioned against
against each
including the cost of materials,T&P materials and each classification
classification
labour charges with all lead and lift, for lattice shall be adopted.
61 a) shall be adopted.
type station structures,Tr. Plinth, control panels, 2) For
2)
mounting structures for Breakers, CT's PT's the above basic
For the above
Isolators, LA's, etc., rate add
basic rate add
applicable area
applicable area
weightage as per
weightage as per
latest KPWD SR.
latest KPWD SR.

Rates under plain Rates under


concrete for plain concrete
62 i) 1:4:8 concrete (M 7.5) Cmt
foundation of for foundation of
latest KPWD SR latest KPWD SR

Rates under Rates under


63 ii) 1:3:6 concrete (M-10) Cmt basement of latest basement of
KPWD SR latest KPWD SR

Rates under raft Rates under raft


64 iii) 1:2:4 concrete (M-15) Cmt foundation of foundation of
latest KPWD SR latest KPWD SR

Rates under raft Rates under raft


65 iv) 1:1.5: 3 concrete (M-20) Cmt foundation of foundation of
latest KPWD SR latest KPWD SR

For arriving at the For arriving at


rates for concrete the rates for
items for concrete items
transmission lines for transmission
Concreting and curing as per specifications
add 25% lines add 25%
including the cost of materials, T&P materials
66 b) Cmt weightage to the weightage to the
and labour charges with all lead and lift, for Tr.
basic rates of basic rates of
line towers.
different different
proportion of proportion of
concrete proposed concrete
above. proposed above.

Note :
a) Extra as indicated in the relevant KPWD SR
may be allowed
for providing concrete in watery situation
including cost of bailing out water and removing
slush.
b) Only machine mixing is to be used for
concreting.
c) Jelly to be used is 20mm and down size for
1:1.5:3, 1:2:4 and 1:3:6 concrete and 40mm and
down size for CC 1:4:8.
9 Towers
Sorting of tower parts made of fabricated angle
67 a) MT 306 346
iron
Setting up of stubs templates and from one Per
68 b) 398 450
location to another location Location

Assembling and errection of towers including


tightening of bolts and nuts including
69 c) MT 2224 2513
loading,unloading at store and site (Including the
Wt. of stubs)

Rivetting of tower bolt ends by heating using dry-


Acetylene gas and hammering to destroy threads
so as to make the tower members theft - prrof
70 d) Per Bolt 10 12
(Bolts at nodal points only to be selected and
rivetted up to hieght of bottom cross arm, as per
the directions of the field engineer)

71 e) Welding of bolts and nuts Per Bolt 9 12


Note: For tower errections requiring shutdown
25% above S.R. for item 5c to 5e only are to be
adopted.
10 Supplying and fixing AC devices:
Supplying and fixing G.I. Angle iron 45x45x5 mm
(1mtr length) with cleats, bolt & nuts as per
72 a) specification and fixing above 0.5 mtrs length Per Set 2176 2459
each at inner and outer surface of the tower to
facilitate running of barbed wire.
Supplying and fixing barbed wire as per
73 b) Rmtr 41 47
specification
11 Fixing of Boards
74 a) Fixing Danger Board Nos 43 48
75 b) Fixing Number Plate Nos 43 48
Set (3
76 c) Fixing Phase plate 125 141
Nos)
77 d) Fixing Circuit Plates Nos 43 48
Stringing conductor with out allowing the
12 conductor to touch the ground and
damaging the conductor

Paving out the conductor from anchor to anchor


normally spaced at 5 spans with 4 tangent towers
in between, including providing stays at each
anchor points and jointing of conductors, hositing
anf fixing of insulator string, armour
A rods,vibration dampers, including the cost of
TY&P materials like comealong, wire ropes,
pulley, rollers, suspesnion, clamps, compression
jointing machines with bits , drum stands,
manila ropes, truckker and jeep etc(Rate of 1
route KM of single conductor)

9088 With Coyote 10269 With


78 i For hilly tarrian KM
ACSR Coyote ACSR
9088 with Rabbit 10269 with
79 ii
on towers Rabbit on towers
6662 With Coyote 7528 With
80 i For plain Tarrian KM
ACSR Coyote ACSR
3330 with Rabitt 3763 with Rabitt
81 ii
on towers on towers

Stringing of Ground Conductor as above


82 For hilly tarrian KM 4447 5025
83 For plain Tarrian KM 3331 3764
Note:

50% more above


50% more above
the rates
the rates specified
specified for
for normal works
normal works is
is admissible for
admissible for
II) For shut down works 50% more than the shutdown works
shutdown works
above rates of the Work (This is applicable to of 33 kV and
84 of 33 kV and
shutdown of 33 kV and above lines only. 11 kV above lines, CTs,
above lines, CTs,
and LT lines shutdown not included). PTs, Las only.
PTs, Las only.
This is not
This is not
applicable for 11
applicable for 11
kV and LT Line
kV and LT Line
shut down works.
shut down works.

III) (A) River Crossing works


85 (B) Railway Crossing Works 100% extra 100% extra
(C) Breakdown works in substations & lines
IV) 2nd Circuit stringing with 1st circuit under
86 75% extra 75% extra
live condition
V) (A) National highway and State highway
crossing works
87 50% extra 50% extra
(B) Works under shutdown condition in both
substation and lines (Pre-programed works)

Stringing Conductors for short lengths:


These Rates are applicable only when
13 total Length of the entire Line is less
than 3 spans (River crossing, railway
crossing Etc.,).
A) Stringing of conductors in special conditions
where normal 5 spans between anchor to anchor
are not encountered, whereas anchors are
provided at single/ two/ three spans with average
span intervals of 267/320 Mtrs, (rate for spans of
single conductor)

i) For hilly terrian

88 a) Anchoring single span upto 320 mtrs. 1 Span 5128 With Coyote 5795 With Coyote

89 2511 With Rabitt 2837 With Rabitt


b) Anchoring 2 span interval upto 640 mtrs with
90 2 Spans 6358 With Coyote 7185 With Coyote
1 tangent tower only
91 3037 With Rabitt 3432 With Rabitt
c) Anchoring 3 span interval up to 960 mtrs with
92 3 Spans 7456 With Coyote 8425 With Coyote
two tangent towers only
93 3588 With Rabitt 4054 With Rabitt
ii) For plain terrian
94 a) Anchoring single span up to 320 Mtrs 1 Span 3847 With Coyote 4347 With Coyote

95 1853 With Rabitt 2094 With Rabitt


b) Anchoring 2 span interval upto 640 Mtrs with
96 2 Spans 4926 With Coyote 5566 With Coyote
1 tangent tower only
97 2272 With Rabitt 2567 With Rabitt
c) Anchoring 3 span interval up to 960 mtrs with
98 3 Spans 5519 With Coyote 6236 With Coyote
two tangent towers only
99 2665 With Rabitt 3011 With Rabitt

Rates for Short span stringing in Normal


14 length of the line of more than 3 spans
comprising of short spans

A) Stringing of conductors in special conditions


where normal 5 spans between anchor to anchor
are not encountered, where as anchors are
provided at single/ two/ three spans with average
span intervals of 275/320 Mtrs (Rate for spans of
Single Conductor)
i) For hilly terrian
100 a) Anchoring single span upto 320 Mtrs 1 Span 764 With Coyote 863 With Coyote
101 374 With Rabbit 423 With Rabbit
b) Anchoring 2 span interval upto 640 Mtrs with
102 2 Spans 1270 With Coyote 1435 With Coyote
1 tangent tower only
103 612 With Rabbit 692 With Rabbit
c) Anchoring 3 Span interval up to 960 Mtrs with
104 3 Spans 1862 With Coyote 2104 With Coyote
two tangent towers only
105 898 With Rabbit 1015 With Rabbit
ii) For Plain terrian
106 a) Anchoring single span upto 320 Mtrs 1 Span 573 With Coyote 647 With Coyote
107 278 With Rabbit 314 With Rabbit
b) Anchoring 2 span interval upto 640 Mtrs with
108 2 Spans 935 With Coyote 1057 With Coyote
1 tangent tower only
109 458 With Rabbit 518 With Rabbit
c) Anchoring 3 Span interval upto 960 Mtrs with
110 3 Spans 1383 With Coyote 1563 With Coyote
two tangent towers only
111 697 With Rabbit 788 With Rabbit

15 Grounding of Towers/Equipments Material + Labour Material + Labour

a) Grounding of towers including cost of 40mm


dia 2.5 mm thick, class 'C' G.I. Pipe of 3 Mtrs
112 length as per specifications, with 50X6 mm GI Set 3471 3010+832
Flats 3 Mtr long, salt charcoal, including
excavation charges.
b) Grounding of towers/Equipments excluding
the cost of G.I. Pipe/C.I. Pipe as per specifications
with 50X6 mm G.I. Flat 3 Mtr Long (to be
113 Set 1670 789+832
supplied departmentally). But salt & Charcoal to
be supplied by contractor. The rates include
excavation charges.

c) Grounding of equipments by providing cast


iron pipe of 100mm ID 13mm thickness, 2.75
Mtrs long with 2 part clamp out of G.I.Flat
114 50X6mm continuously welded alround the pipe Set 2334 1582+1055
using cast iron welding electrodes as per drawing
including the cost of excavation (All materials to
be supplied by the contractor)

Note : All the leads from earthmat &


equipment should be connected to earth
electrode through the GI Flat 50 x 6 mm of
suitable length and welded as per
specifications.

Supplying and fixing of counter poise earthing


with GI Stranded wire where hard rock is
115 16 Per Loc 4585 2143+1916
encountered as per specifications. (including
excavation charges).

17 Station Structures
Errection, assembly and alignment of Station
116 a) MT 2099 2372
structure as per the directions of site Engineer.
Erection, alignment & assembly of fabricated
steel lattice structure, pedestal structures &
117 b) MT 1956 2210
Mounting structures, for G.O.S., CT's, PT's LA's
etc.,
18 Erection of Transformers
Moving the Transformer on to the plinth
(Maximum allowable distance is 50 mtrs.) more Per MT/
118 a) 41 47
than 50 mtrs. approval of the CEE, O&M Zone Mtr
has to be obtained)
Assembly of Transformer parts like bushings,
119 b) radiators, filling oil into Tr. etc., (for the total wt. MT 938 1059
of the Tr.)

Filling oil to the power Tr., Conservator and


c)
radiator (for maintenance purpose only).

120 i) For 5 MVA to 20 MVA Tr. Litre 2 2


Filtration of oil using filter set of the contractor,
121 d) Litre 4 4
to bring the insulation value to I.E. Specifications.
Filtering Oil as above but with the filter set
122 e) Litre 2 2
supplied by the ESCOM
Wiring of Transformer marshalling box,
bucholtz relay, fixing Thermometer, OLTC
19 upto control panel and assisting in
testing and commissioning by
RT/MT/Firm Engineers.
123 i) 5 MVA to 6.3/8 MVA Tr. LS 4314 4875
Fabrication of Transformer railing and
20 embedding in Transformer plinth. (Rails LS 866 979
to be supplied by the HESCOM)
Per Set
21 Fixing of H.T. fuse units & wiring 1008 1138
(3 Nos)
Wiring Testing & Commissioning of 5 MVA
22
33/11 kV Power Transformers
a) Wiring: Identification of wires, Ferruling
crimping and termination of wires. Wiring of
124 8370 5917
Protective Devices, Cooling fans, Oil flow Pumps,
OLTC, RTCC

b) Testing:
1. Ratio
Test
2. SC test

3. Excitation test
4.
Magnetic Balance test
125 5. Vector group test. Each 33481 23668

6. induced high voltage test.


7. OLTC
operation.
8. Protective devices
operation checks.
9. stability checks:- for differential
and REFR protection

Erection of Breakers / 11 kV Kiosks with


23
CTs on Mounting Structures
a) BREAKERS
Erection, assembly, alignment & interpole wiring
of breakers with its connected equipments
126 i) Per Set 4966 6654
including movement from the point of unloading
to the point of erection.
127 ii) Assisting in Testing and Commissioning Each 995 1333
Testing & Commissioning:

Wiring: Identification, of wires Ferruling crimping


128 and termination of wires in Breaker & Wiring up Set 41848 5917
to control panel / Relay panels.

Testing: Test for insulation level, gas leakage,


Testing for travel time, Trip and close timings.
129 Local Trip close Test, Remote trip and close test, Set 23668
Tripping rhrough relays, operation of interlocks
etc.,
24 Erection of CTs and PTs
Erection of CTs and PTs and wiring including
Set
130 a) movement from the point of unloading to the 1530 1729
(3 Nos)
point of erection.
131 b) Assisting in Testing and Commissioning Set 460 520
c) Testing & Commissioning
Current transformers:
Wiring:
Indentification of wires Ferruling Crimping of
lugs Connections up to marshalling box and Set
132 i) 13947 9860
Control panel. Current transformers: (3 Nos)

Tests:
Insulation, Polarity, Ratio,
Potential Transformers: Excitation
Wiring:
Indentification of wires Ferruling
Crimping of lugs Set
133 ii) 13947 9860
Connections up to marshalling box. (3 Nos)
Potential Transformers:
Tests: Insulation,
Polarity, Ratio,excitation.
25 Erection of NCTs
Erection of NCTs with ground including
134 a) movement from the point of unloading to the Set 443 500
point of erection
135 b) Assisting in Testing and Commissioning Set 56 64
26 Erection of Isolators
Assembly, Errection alignment and wiring
136 a) including movement from the point of unloading Set 920 1040
to the point of erection. (Upright)
137 b) Assisting in Testing and Commissioning (Upright) Set 94 106
Note :

1) Assisting in
testing and commissioning for item No. 13 to 18
means contractors should provide labourers for
testing and commissioning by RT/MT/Firm
engineers.
2) Testing &
Commissioning in item 13 & 18 means the
testing will be carried out bythe firms themselves
using their own testing equipments and staff in
presence of the MRT staff who will witness the
tests.
27 Erection of Lightening Arrestors
Erection of Lightning arrestors and wiring
138 including movement from the point of unloading Set 230 260
to the point of erection
139 28 Fixing of Solid Core insulator Per Stack 76 86

Testing & Commissioning: Capacitor Bank


140 29 Each 18830 15325
with reactors
Control Cables and U.G. Cables
30 Formation of Cable Duct

(i) Burnt brick/size stone/RCC Cable duct As per Latest As per Latest
including form box, back filling the sides, KPWD electrical KPWD electrical
141 a) Cmt
removing the excess escavated soil, duct covering SR applicable to SR applicable to
with RCC slabs. respective areas. respective areas.
(ii) Supplying 300 mm dia 1.5" to 2" thick RCC
As per Latest As per Latest
Hume pipes including loading unloading, and
KPWD electrical KPWD electrical
142 transportation charges and laying at required Rmtr
SR applicable to SR applicable to
level and gradient as per the direction of field
respective areas. respective areas.
engineer

Providing, laying and jointing PVC pipes


conforming to IS 4085-1960, & 7634-1975, and
approved makes with necessary specials such as As per Latest As per Latest
collars, bends, Elbows, Tee, nipples, plugs with KPWD electrical KPWD electrical
143 b)
cuts and threads using jointing ring with SR applicable to SR applicable to
solutions, wherever necessary as per the respective areas. respective areas.
directions of the field Engineer including all lead
and lift.

144 i) 25 mm dia (outer) 2mm to 2.5mm thick Mtr


145 ii) 32 mm dia (outer) 2mm to 2.5mm thick Mtr
146 ii) 63 mm dia (outer) 2mm to 2.5mm thick Mtr As per Latest As per Latest
147 iv) 75 mm dia (outer) 2mm to 2.5mm thick Mtr KPWD electrical KPWD electrical
148 v) 90 mm dia (outer) 2mm to 2.5mm thick Mtr SR applicable to SR applicable to
149 vi) 110 mm dia (outer) 2mm to 2.5mm thick Mtr respective areas. respective areas.
150 vii) 140 mm dia (outer) 2mm to 2.5mm thick Mtr
151 vii) 160 mm dia (outer) 2mm to 2.5mm thick Mtr
Supplying & Laying cable trays including
152 d) Material+Labour Material+Labour
welding fixing of supports
Cable tray of 600mm width (suitable for cable
153 i) Rmtr 537 302+209
ducts of A,B & C type)
Cable tray of 300mm width (suitable for cable
154 ii) Rmtr 383 221+141
ducts of A,B & C type)
Laying of control cables from equipments to
155 e) Rmtr 8 10
control panels.
31 Control Panels
Erection of control panels, auxilary panels,
carrier cabinets etc., alignment and fixing
156 a) properly to foundation base including movement Per Panel 3055 3452
from the point of unloading to the point of
erection.
Wiring & assisting in testing and commissioning
157 b) Per Panel 4774 5394
of panels.

Test & Commissioning:


i) C& R Panels
Wiring & Testing:
Wiring:Identification, Ferruling, Crimping,
158 C) termination of wires in C&R panels. Each 41848 29585
Testing: Testing for insulation level,
Testing of relays, control operations for closing
tripping etc., interlocks Alarm, Annunciation and
Indication Checks.

32 11 kV Switchgear
Erection, alignment and fixing to the foundation,
indoor/outdoor 11kV switchgear Panel/unit
159 a)
including movement from the point of unloading
to the point of erection.

160 i) 11kV Indoor/out door switchgear Per Panel 1839 2078


161 ii) 11kV Kiosk Per Panel 1530 1729

b Wiring & assisting in testing & Commissioning

162 i) 11 kV indoor/ outdoor switchgear Per Panel 610 689

163 ii) 11kV Kiosk Per Panel 610 689

Testing & Commissioning:


Wiring:
Identification of wires, Ferruling Crimping &
c
Termination of wires for annunciation, etc.,
Testing of Relays, CTs, PTs, & Breaker for
operation
For indoor/outdoor panel comprising of
164 i) Per Set 69753 65503
2I+8F+1BC+1AP3
165 ii) For single 11kV panel indoor/outdoor type /Kiosk Nos 13950 13098
166 iii) For additional 11kV panel indoor Nos 6975 6549
For each additional 11kV panel out door
167 iv) Nos 10661 10009
type/Kiosk
Note:Assisting in testing & Commissioning for
item 19,20 & 21 mean contractors should
provide labourers for wiring & Commissioning by
RT/MT/Firm Engineers.
33 Busbar Formation
Main bus/cross bus (all the three phases in a
segment) of using Coyote-single/double
conductors with fixing of insulator spacers,
168 levelling of string conductors to the required
height above the equipment, including providing
jumps to interconnect different segments of the
main bus.

Main Bus/Cross Bus as above using Single Lynx


169 a) 2961 6152
Conductor
Main Bus/Cross Bus as above using Single
170 b) 2961 6152
Coyote Conductor
Formation of cross bus in each individual bay
using Lynx/Coyote - Single/Double conductor
with fixing of insulators, spacers, levelling the
171 b) Per Bay 5640 Deleted
strung conductors to the required height above
the equipment including providing jumps to inter-
connect different segments of the main bus.

172 34 Faradays Cage Formation as per specification: Per Bay 225 254

35 Groundmat
Laying of M.S. Flats, welding, applying ACB paint
173 a) to welded portion and covering with sodium Rmtr 25 33
bentonite clay

Supplying and laying of MS flats, of various sizes, 50x6mm - 262 50x6mm - 273
welding and applying ACB paint to welded 50x8mm - 280 50x8mm - 291
b)
174 portion and covering with sodium bentonite clay, Rmtr 75x6mm - 486 75x6mm - 566
as per the drawing/standard specifications and 75x8mm - 514 75x8mm - 505
consolidation. 75x12mm - 545 75x12mm - 535
50x6mm - 129 50x6mm - 135
50x8mm - 146 50x8mm - 152
175 c) Same as above but without sodium bentonite clay Rmtr 75x6mm - 353 75x6mm - 367
75x8mm - 380 75x8mm - 395
75x12mm - 413 75x12mm - 429
Grounding of equipment with various sizes, G.I.
Flat and connecting Equipment to the
earthmat/ground pit. Each point of earthing 50x6mm - 217 50x6mm - 226
with all formation works like bending, twisting, 50x8mm - 242 50x8mm - 253
176 d) drilling of holes and connecting by welding Per point 75x6mm - 520 75x6mm - 541
(inclusive of all T&P and consumables) to the 75x8mm - 549 75x8mm - 571
earthmat/ ground pit/ point of earth 75x12mm - 594 75x12mm - 618
connection,all the materials supplied by the
contractor.
Providing 25mm dia M.S.rod 1.05 Mtr. Long
earthmat spikes including heating, bending top
50mm over lap flattening and making spike edge
177 e) Each 239 260
at one end driving into the earth below the
ground level and welding the rod with ground mat
flat.
Supplying & Providing 450 mm dia 450 mm
height 1.5" to 2" thick hume pipe collar (non
178 f) Each 689 864
pressure type) for earth pits including all lead and
lifts etc.,
36 Providing Deep Bore earthing

"Sinking bore of 150mm clear dia using fast rig


including fixing of 40mm dia MS rod, including
jointing the pipes as per KPTCL standard and
providing sodium bentonite treatment in the
179
annular space, including transportation of rig and
other supporting vehicles etc., complete, as per
the directions of engineer in charge, including
cost of MS rod & sodium bentonite".

180 a) Drilling 150mm dia bore Rmtr 547 687


181 b) 40 mm dia MS rod Rmtr 432 541
182 c) Bentonite Clay Kgs 14 15
d) Cost of GI flat for joining two rods by welding
183 Per joint 525 572
to obtain continuous length
37 Spreading of Jelly
Supplying and spreading 100mm thick with
184
20/25mm jelly with all lead and lifts.
185 i) 20/25 mm Jelly Cmt 1156 1427
Note : Only 20/25mm jelly shall be used.
38 Station Yard Lightning

As per Latest As per Latest


a) Supplying and erection of fabricated KPWD electrical KPWD electrical
186 Per Set
supporting structures including foundation. SR applicable to SR applicable to
respective areas. respective areas.
As per Latest As per Latest
b) Supplying and fixing of Sodium Vapour lamp Per KPWD electrical KPWD electrical
187
fittings of 250 watts. Fitting SR applicable to SR applicable to
respective areas. respective areas.

As per Latest As per Latest


c) Supplying and laying of 1.1KV, 6 Sqmm PVC
KPWD electrical KPWD electrical
188 cable or any other specified size, testing and Rmtr
SR applicable to SR applicable to
commissioning of yard lights.
respective areas. respective areas.

d) Erection of RCC poles with stringing of O.H. Furnished in Furnished in


189
conductor/Laying of cable for yard lights. 11kV Works 11kV Works

39 Painting of structures Material+Labour Material+Labour


a) Supplying and painting of two coats of good
190 quality Red Oxide primer after cleaning and Sq Mtr 62 23+46
scrapping the surface.
b) As above with 2 coats of good quality
191 Aluminium paint after2 coats of good quality Red Sq Mtr 106 50+70
Oxide primer.

c) Supplying and painting two coats of aluminium


192 paint after cleaning and scraping the surface Sq Mtr 55 24+39
wilthout applying Red Oxide primer

193 d) As per (b) but with synthetic enamel paint Sq Mtr 121 60+77

e) Supplying and painting two coats of Synthetic


194 enamel paint after cleaning and scraping the Sq Mtr 62 32+37
surface without aplying red oxide primer.

40 Battery Set and charger


Installing, assembling, filling of acid, wiring,
195 a) assisting, test-charging and discharging Battery
set.
196 i) 110 Volts Set 7639 8632
197 ii) 48/24 Volts Set 3059 3456
198 b) Erection of Battery Charger and wiring
199 i) 110 Volts Set 1220 1379
200 ii) 48/24 Volts Set 1220 1379
Testing & Commissioning of Battery Charger:

Wiring: Identification, Ferruling, Crimping &


c) connecting
i)AC Supply cable upto 2 sources
ii) Load cables,
connection at charger end upto 10 load points
Testing:
i) AC supply
Voltage Phase Sequence.
ii) Testing of
Output DC Voltages in
Boost/Float/Trickle/Variations as per the
order/requirement .
iii) Testing for
Ripple Factor.
Commissioning:
i) Fixing of Boost
Voltage level
ii) Fixing of Float Voltage
level
iii) Fixing of Trickle Volage level
iv) Testing of alarm, indication and load ckts,
Auto /Manual change overs etc.
v) Full load test in Boost & Trickle modes.
201 i) 110V DC: (1 set for 33kV Stations) Per Set 21300 17042
41 Fencing :
Colony and Station yard Boundary fencing
including erection of supports

As per KPWD SR As per KPWD SR


a) Security fencing using 8SWG chainlink/50mm
202 applicable to applicable to
Mesh
respective area respective area
203 b) Barbed wire fencing ? ?
42 PLCC Equipments
Erection of mounting structures for coupling
204 a) Set 4347 4912
capacitors
205 b) Erection of Coupling capacitors/wave traps/LMU. Set 1634 1846
206 c) Wiring , testing and commissioning Set 486 486
43 Yard Levelling
As per KPWD SR As per KPWD SR
Yard Levelling and filling up of soil and
207 Cmt applicable to applicable to
consolidation.
respective area respective area

44 Watch and Ward


Emoluments for watch and ward including pay
208 Per shift 244 276
and DA for 8 hours duty
45 Transportation
Transportation of Transformer, CT's, PT's,
209 Breakers, C&R Panels, 11KV Switchgears and
EHT LA's only.
a) Using 10 MT Lorry

Rs. 53/- per KM, Rs. 60/- per KM,


210 i) 1 to 50 KMs subject to a Min. subject to a Min.
of Rs.10000/- of Rs.10000/-

Min + Rs.40/- per Min + Rs.45/-


211 ii) 51 to 100 KMs
KM per KM
Min + Rs.30/- per Min + Rs.34/-
212 iii) 101 to 150 KMs
KM per KM
Min + Rs.19/- per Min + Rs.21/-
213 iv) Beyond 150 KMs
KM per KM
b) Using 10 MT Truck & Trailor
Rs. 53/- per KM, Rs. 60/- per KM,
214 i) 1 to 50 KMs subject to a Min. subject to a Min.
of Rs. 2000/- of Rs. 2000/-

Min + Rs.40/- per Min + Rs.45/-


215 ii) 51 to 100 KMs
KM per KM
Min + Rs.30/- per Min + Rs.34/-
216 iii) 101 to 150 KMs
KM per KM
Min + Rs.19/- per Min + Rs.21/-
217 iv) Beyond 150 KMs
KM per KM
c) Using 20 MT Truck & Trailor.
Rs. 475/- per
Rs. 420/- per KM,
KM, subject to a
218 i) 1 to 50 KMs subject to a Min.
Min. of Rs.
of Rs. 25000/-
25000/-
Min + Rs 350 /- Min + Rs 396 /-
219 ii) 51 to 100 KMs
per KM per KM
Min + Rs 190/- Min + Rs 215/-
220 iii) 101 to 150 KMs
per KM per KM
Min + Rs 170/- Min + Rs 192/-
221 iv) Beyond 150 KMs
per KM per KM
Mobilisation charges of IDLE Transportation
applicable for places where heavy duty trucks are
221 26 30
not available, is admissible in addition to: (a) as
far as possible full load shall be transported.

222 b) Transportation of other materials 27% of the above 27% of the above
c) Using light vehicle including fuel, oil,
lubricants and crew subject to a minimum of 100 Prevailing Board Prevailing Board
223 Per Set
Kms per day in case of break down/ subject to approved Rates approved Rates
prior approval of CEE.
46 Loading and Unloading
a) Loading of Power Trs, CT's. PT's Breakers, C&R
Panels, 11KV Switchgears, wavetrap, coupling
224 MT 1614 1824
capacitors, HT UG Cables, Insulators, ACSR
Conductor, Ground Conductors, etc.,

b) Unloading of power Transformers, CT's PT's


Breakers, C&R Panels, 11 KV Switchgears,
225 Wavetrap, coupling capacitors, HT UG Cables, MT 1614 1824
Insulators, ACSR conductor, Ground conductors,
etc.,
c) Loading of other materials like structural
226 MT 286 323
steel, building materials etc.,
d) Unloading of other materials like structural
227 MT 286 323
steel, building materials etc.,

47 Benching, Revetment and Pitching

Providing granite rough stone 30 to 50 cms thick For substation For substation
dry packing of revetments and pitching side works as per works as per
slopes of quadrant including providing the walls, KPWD SR and for KPWD SR and
228 Cmt
jelly packing, 0.15 cms thick and wedging etc., Transmission line for Transmission
Complete including cost of conveyance of all works Add 25% line works Add
materials. extra 25% extra

Labour for 33KV lines using 9/9.5 Mtrs


48
Long RCC Poles
a) Erection of 9/9.5 Mtrs RCC Poles 300 Kg
working load, in the excavated pit as per the
229 approved drawing specification including the cost Nos 1216 1374
of excavation, backfilling(Concreting charges
extra)
b) Erection of DP structure including fixing of
braces insulators etc., as per the approved
230 drawings and specifications including the cost of Set 2876 3250
excavation, backfilling (Concreting charges extra).

c) Fixing of V-Shape cross arms, single top


231 Set 85 96
supports and insulators.
232 d) Fixing of spiral earth electrodes Nos 31 55
233 e) Road/P&T Guarding Set 840 1059
f) Stringing Rabbit conductor, fixing disc
234 KM 2308 2608
insulator to cross arms etc.,
g) Stringing Coyote conductor, fixing disc
235 KM 4031 4031
insulator to cross arms etc.,
h) Supplying and fixing of AC devices as per As provisioned in As provisioned in
236 Rmtr
specification 11 kV works 11 kV works
49 Dismantling
Same rate as
Same rate as that
that of erection
237 i) Dismantling of Power Transformer of erection of
of Power
Power Transformer
Transformer
ii) Dismantling charges for conctrete with steel
238 Cmt 707 799
reinforcement
239 iii) Dismantling of concrete only Cmt 345 390
75% of erection
75% of erection
240 iv) Dismantling charges in all other cases charges in
charges in general
general
BILL OF MATERIALS-1
For 11 kV DP structure Kit as per Drg No. SIC/DL/WSO 18/29-7-85
16 mm 20 mm Clamps made
Total
Sl Wt/Mtr in Hexogon Class 'A' out of
Particulars MS Angle/Flat in mm Qty Wt/Set Qty
No Kgs al Bolt & GI Pipe in 50x6 mm MS
in kgs
Nut Length Flat
1 2 3 4 5 6 7 8 9
175 mm 120 mm
2 5.8 27.14 6 type-CDP-1
HT power x-arm out of 65x65x6 size Long 2 Nos
1 2 Nos.
2.34 mtrs Long 50 mm 60 mm
6 2.16 kg/set
Long 3 Nos
Brace X-arm (Horizontal member) 50x50x6 size 65 mm type-CDP-2
2 2 4.5 14.4 8
1.6 mtrs Long Long 2 Nos.
Brace X-arm (cross member) 50x50x6 size 50 mm
3 2 4.5 25.2 5
2.8 mtrs Long long
Strain Plate 50x8 size 6 mm thick
4 3 3.2 3.49
0.375 mtrs Long washer 1No.
Note :
1. All holes are of 18 mm for 16 mm bolts
2. All Sllotted holes are of 18x35 mm long
3. The weights given are for raw materials as per ISI structural steel hand book
BILL OF MATERIALS -2
FOR 100 TO 300 kVA TRANSFORMER CENTER KIT (For double pole TC Structure)

16 mm dia 20 mm
Length/ Hexaganal dia. Class
SL. MS Angle Wt/Mtr in total wt/set Qty in
Particulars Qty piece in Bolt & Nut 'A' GI Pipe
No Flat in mm Kgs in kgs No
mm x Nos Length in Length in
mm mm/Qty

65x65x6 5.8 2,700x2 31.2 175 4 0


1 HT Power Cross arm & strain plate 1 Set
50x6 2.4 375x3 2.7 50 6 0
45x45x6 4 2,350x2 18.8 75 4 0

2 a) GOS Frame 1 No. 40x40x5 3 340x2 2.04 0 0 0


40x40x5 3 70x4 0.84 0 0 0
40x40x5 3 60x6 1.08 0 0 0
b) Pin insulator support 1 Set 50x6 2.4 400x3 2.88 0 0 0
50x50x6 4.5 2,350x1 10.58 0 0 0
c) LA Fixing X-arm 1 Set
45x45x6 5 70x2 0.56 0 0 0
65x65x6 5.8 1,025x2 11.86 0 0 0
d) GOS & LA Support X-arm & Clamp for fixing on to the pole 1 Set
50x6 2.4 436x2 2.15 65 4 0
e) GOS & LA Supporting Brace 1Set 45x45x6 4 1,260x2 10.08 50 4 0
65x65x6 5.8 2,350x1 13.63 0 0 0
f) HG Fuse Fixing X-arm 1 Set
65x65x6 5.8 70x2 0.812 85 2 0

65x65x6 5.8 925x2 10.73 0 0 0


g) HG Fuse support X-arm & Clamp for fixing on to pole 1 Set
50x6 2.4 496x2 2.27 65 4 4
45x45x6 4 1,360x2 10.88 0 0
h) GOS, LA & HG Fuse supporting brace & clamp for fixing to
1 Set 50x6 2.4 463x1 2.41 0 0 4
pole
0 285x2 1.37 65 4
45x45x6 4 2,700x2 21.6 0 0
3 Transformer belting angle Clamp for fixing on to pole 1 Set 45x45x6 4 500x2 4 40 4 0
50x6 2.4 493x2 2.44 65 4
100x50x4.7 9.2 2,700x2 49.69 225 7 185 mm
a)Transformer seating channel supporting cleat X-arm & clamp
4 1 Set 65x65x6 5.8 310x2 3.6 0 0 3 No
for fixing on to pole GOS (ISMC)
50x6 2.4 523x2 2.44 65 4 0
a) GOS Handle supporting X-arm & clamp for fixing on to pole 65x65x6 5.8 1,150x1 5.89 0 0 0
1 Set
GOS 50x6 2.47 548x1 1.32 65 2 0
5 45x45x6 4 1800x1 0 0 0
b)Handle supporting X-arm brace & clamp for fixing on to pole 1 Set 50x6 2.4 560x1 6.11 0 0 0
50x6 2.4 320x1 65 2 0
Note : 233.962
1) The bill of materials are prepared as per Dgr No..KEB/SIC/WS/022/date :12.9.86
2) The weights given are for raw materials as per ISI structural Hand book.
3) All holes are of 18 mm & solt holes 18x35 mm to suit 16 mm unless otherwise stated
4) Bolts required to fix LA's & G.O.S down take off pipe are not included as the same are to be supplied along with equipments,
5) LT.4 pin X-arm & clamp are also not included as they are readily available.
BILL OF MATERIALS-3
3 Pole Structure for Transformer
Length
Sl MS Angle Wt/Mtr in Wt/Set in
Particulars Unit /Nos in
No Flat in mm Kgs Kgs
mm
1 2 3 4 5 6 7
50x50x6 4.5 1280x3 17.28
1 HT Side power Cross-arm and strain plate 1 Set
50x6 2.4 463x2 2.22
GOS Support Cross arm & Clamp for fixing on to the 65x65x6 5.8 2000x2 23.2
2 1 Set
pole 50x6 2.4 463x2 2.09
45x45x6 4 2350x4 37.6
45x45x6 4 310x4 4.96
3 GOS Frame 2 Nos
45x45x6 4 70x8 2.24
45x45x6 4 60x12 2.28
45x45x6 4 1360x4 21.76
4 GOS Supporting Cross arm and Clamp 1 Set 50x6 2.4 498x2 2.39
50x6 2.4 285x2 1.37
a) GOS Handle Supporting Cross arm Brace and 65x65x6 5.8 2000x1 11.6
1 No
Clamps 50x6 2.4 423x2 1.26
5 45x45x6 4 1000x2 8.00
b) GOS Handle Supporting Cross arm brace and
50x6 2.4 50x1 1.34
Clamps
50x6 2.4 320x1 0.77
50x50x6 4.5 2700x2 24.3
6 Brace Cross Member and Clamps 1 Set
50x6 2.4 493x2 2.31
BILL OF MATERIALS
FOR 25 TO 63 kVA TRANSFORMER CENTRE KIT (This BoM is suitable for Convention

Sl. MS Angle/ Wt/Mtr


Particulars Qty
No Flat in Kgs

1 Set
1 HT + LT side power X-arm 65x65x6 5.8
2 No

2 P.I support X-arm 1 No 50x50x6 4.5

1 Set 45x45x6 4
3 Belting cross arm and belting support X-arm
4 No 50x50x6 4.5
Transformer Seating and Transformer seating 1 Set
4 65x65x6 5.8
angle support X-arm 4 No
5 Distribution box Fixing Clamps 0 0
6 GI Pipe 0 20x5
7 H Frame Set 0
Note :
1. The bill of materials are prepared as per DRG No.SIC/WS/017/date 28.6.85.
2.The weights given are for raw materials as per ISI structural steel Hand book.
3. All holes are of 18 mm for 16 mm bolts.
4. All slotted holes are of 18x35 mm long.
5. Bolts required to fix Las are not included as the same are to be supplied along with LAs
6 Since the D.O.L.O cut out is being fixed on the pervious support of the T.C and depending on
ILL OF MATERIALS-4
suitable for Conventional Transformer Only, Separate BoM- 6 is furnished for Star Rated
Clamp
made
Length/ Total 16 mm dia 20 mm
out of
Piece in Wt/Set in Hexgonal Qty class 'A' GI Qty Qty
No.Bolt & Nut
50x6
mtr x No kgs pipe
mm MS
flat No
2.7x2 31.32 175 7 120 3 0 0

2.7x2
12.96 65 4 0 0 460 2
(0.06x3)
2.7x2 50 4 0 0 0 0
21.6 4.5
0.5x2 65 4 0 0 465 2
2.7x2 31.32 12 7 0 0 0 0
0.285x2 3.19 50 4 160 3 465 2
0 0 120 0 3 536 2
160 0 0 0 3 0 0
1 No 62.69 0 0 0 0 0 0

e 28.6.85.

plied along with LAs


he T.C and depending on whether it is single support & DP structure provision for D.O.L.O fixing X
or Star Rated

Wt/Set
in Kgs

2.16

0
2.23
0
2.23
2.6
0
0

D.O.L.O fixing X
BILL OF MATERIALS-5
H.FRAME
Sl. MS Angle Wt/Mtr Length in Wt/Set in
Particulars Unit
No Flat in mm in Kgs mm Kgs
1 2 3 4 5 6 7
No 65x65x6 5.8 1200x2 13.92
1 GOS- H Frame Fixing Cross-Arm
No 50x6 2.4 473x2 2.27
No 45x45x5 3.4 1360x2 9.25
GOS H Frame Fixing Cross arm Clamps Brace Fish
2 No 50x6 2.4 503x2 2.41
Plate
No 50x6 2.4 285x2 1.37
No 45x45x5 3.4 2350x2 15.98
No 45x45x5 3.4 310x2 2.11
3 GOS Frame
No 45x45x5 3.4 70x4 0.95
No 45x45x5 3.4 60x6 1.22
GOS Handle Frame Fixing Cross-arm No 65x65x6 5.8 1100x1 6.38
4
Clamp for above No 50x6 2.4 548x1 1.32
No 45x45x5 3.4 1000x1 3.40
GOS Handle Frame Fixing Cross set arm Brace
5 No 50x6 2.4 558x1 1.34
Clamps Fish Plate
No 50x6 2.4 320x1 0.77
16*50 3 Nos
6 MS Bolts & Nuts 16mm with washers Kgs 16*65 12 Nos
16*150 6 Nos
62.69
Note
1 The hole have to be provided at locations as mentioned in the drawings
2 All holes are in mm and slot holes 18*35 ,, to suit 16mm unless otherwise stated.
3 the weight mentioned in the BoM is as per Steel Table
4 The Bolts & Nuts shall confirm ISS
BILL OF MATERIALS - 6
25/63 kVA TC Structure suitable for mounting Star Rated 25 & 63kVA Transformers
BESCOM for 3 Star Rated
Transformers as
Sl. Wt/Mtr in
Part No. Part No. approved in PFC/ADB
No. Kgs
Approx wt in
Qty/set Kg
MS Angle 65x65x6mm x 2700 mm - HT side Power X arms 5.8 1 No
1 T1 31.32
MS Angle 65x65x6mm x 2700 mm - LT side Power X arms 5.8 1 No
2 MS Angle 50x50x6mm x 2700 mm - PI Support X arms T2 4.5 1 No 12.15
MS Cleat 50x50x6mm x 70 mm 4.5 3 Nos 0.945
3 MS Angle 45x45x6mm x 2700 mm Belting X arms DTC-10 4 2 No 21.6
4 MS Angle 45x45x6mm x 500 mm Belting support X arms DTC-9 4 2 No 4.5
5 MS Channel 100x50x4.7 (ISMC) mm x 2700mm Transformer seating T4 9.2 2 No 49.68
6 MS Angle 65x65x6mm x 310 mm Transformers seating support X arms DTC-11 5.8 2 No 3.6
KIT DETAILS
7 MS Flat 50x6mm x 450mm 2 2.4 2 No 2.16
8 MS Flat 50x6mm x 465mm 3 2.4 4 No 4.46
9 MS Flat 50x6mm x 535mm 4 2.4 2 No 2.6
10 L&R MS Angle 65x65x6mm x 1025mm GOS & LA Support X-Arms DTC-4 5.8 2 No 11.89
11 MS Angle 45x45x5 mm x 1360 mm HG Fuse Support DTC-8 3.4 1+1 No 9.248
12 L&R MS Angle 65x65x6mm x 1100 mm GOS Handle Support X arms Brace DTC-13 5.8 1 No 6.38
13 L&R MS Angle 45x45x5mm x 1000 mm GOS Handle Support X arms Brace DTC-14 3.4 1 No 3.400
11kV H Frame Set details
MS Angle of size 45x45x6 mm x 2350 mm 4 2 No Each 18.8
14 40x40x5mm 340mm DTC-3 3 2 No Each 2.04
40x40x5mm 70mm 3 4 No Each 0.84
40x40x5mm 60mm 3 6 No Each 1.08
Clamps
15 MS Flat 50x6mm x 560 mm 5 2.4 2 No 2.7
16 MS Flat 50x6mm x 498 mm 1 2.4 2 No 2.39
17 MS Flat 50x6mm x 465 mm 3 2.4 2 No 2.22
FISH PLATE FOR 'H' Frame - GOS Mounting Frames
a) 285 mm 2 No 1.368
b) 320 mm 1 No 0.768
TOTAL a) Structure Steel 196.139
MS Bolts & Nuts Including H Frame
a) 16mm x 175mm 7 No
b) 16mm x 65mm 12 No
18
c) 16mm x 200mm 7 No 10 Kgs
d) 16mm x 50mm 4 No
e) 12mm x 50mm 4 No
TOTAL b) Bolt and nut 10 Kgs
Note: 1) The weight indicated is before punching of the holes.
2) Tolerance of ±4% is allowed on the weight.
BILL OF MATERIALS-7
SINGLE POLE MOUNTED TRANSFORMER STRUCTURAL MATERIALS ON 9 MTRS. LONG RCC POLE ( SQ.
SECTION) FOR 25/63 kVA TC SET

Part Length in Weight in


MS Angle size in mm Quantity Wt / Mtr.
No. mm kg.
1 50x50x6 850 1 4.5 3.825
2 50x50x6 1150 2 4.5 10.35
3 50x50x6 850 2 4.5 7.65
4 45x45x5 Not Applicable
5 45x45x5 700 2 3.4 4.76

6 45x45x5 1321 2 3.4 8.98


7 8th Plate Not Applicable
8 65x65x6 485 1 5.8 2.784
9 65x65x6 850 2 5.8 9.86
10 65x65x6 485 1 5.8 2.784
11 45x45x5 1230 2 3.4 8.16
12 45x45x5 1000 2 3.4 6.8
13 65x65x6 with cleat welded on both ends of length 65mm 485 1 5.8 2.9
Clamps
50x8 550 2 3.1 3.41
50x8 480 2 3.1 2.976
Bolts & Nuts (various sizes)
16x125mm 8
16x50 mm 8 4
16x50 mm 4
BILL OF MATERIALS-8
SINGLE POLE MOUNTED TRANSFORMER STRUCTURAL MATERIALS ON 9 MTRS. LONG RCC POLE ( SQ.
SECTION) FOR 100 kVA TC SET.

Part Length in Weight in


MS Angle size in mm Quantity Wt/Mtr
No. mm kg.
1 50x50x6 850 3 4.5 11.475
2 50x50x6 1150 4 4.5 20.7
3 50x50x6 850 2 4.5 7.65
4 45x45x5 900 2 3.4 6.12
5 45x45x5 1500 2 3.4 10.20
6 45x45x5 1321 2 3.4 8.98
Not
7 8th Plate
Applicable
8 65x65x6 485 2 5.8 5.568
9 65x65x6 850 2 5.8 9.86
10 65x65x6 485 2 5.8 5.568
11 45x45x5 1350 2 3.4 9.18
12 45x45x5 1000 2 3.4 6.8
65x65x6 with cleat welded on both ends of length
13 485 1 5.8 2.9
65mm
Clamps
50x8 550 2 3.1 3.41
50x8 480 2 3.1 2.976
Bolts & Nuts (various sizes)
16x125mm 8
16x50 mm 8 5
16x50 mm 4
BILL OF MATERIALS – 9

For OH line (Having Single H Frame with Transformer seating and seating angle support x-arm) for
11mtr Spun Pole for 25KVA Transformer.

Length Qty
Sl No Size of the steel section Kgs/Mtr Total Wt
(in mm) (in Nos)
TOP Bracket
1 100x100x8mm MS Angle 850 3 12.1 30.86
2 75x40x4.8mm MS Channel (MC75/MCP75) 2400 2 7.14 34.27
3 45x45x5mm MS Angle 850 3 3.4 8.67
4 75x40x4.8mm MS Channel (MC75/MCP75) 1040 2 7.14 14.85
5 50x50x6mm MS Angle 1000 2 4.5 9
6 50x50x6mm MS Angle 1000 2 4.5 9
7 65x65x6mm MS Angle 1440 2 5.8 16.7
Transformer Center
8 130x130x12mm Angle 1110 1 23.4 25.97
9 100x50x5mm MS Channel (MC100/MCP100) 1200 2 9.56 22.94
10 130x130x12mm MS Angle (with side plate) 1110 2 23.4 51.95
11 75x75x6mm MS Angle 1750 2 6.8 23.8
12 65x65x6mm MS Angle 1260 2 5.8 14.62
13 75x40x4.8mm MS Channel (MC75/MCP75) 1110 2 7.14 15.85
GOS Mounting Structure (Ladder)
14 45x45x5mm MS Angle 1640 2 3.4 11.15
15 45x45x5mm MS Angle (Cleat) 60 6 3.4 1.22
16 40x40x5mm MS Angle 335 2 3 2.01
Round clamps of different sizes made out of MS flats
suitable for fixing the above structural materials to the
17
pole.
a) 75x6 MS Flat 1000 6 3.532 21.19
MS Hexagonal bolts, nuts and washers of different 15kgs
18
sizes to sufficient in quantity for fixing clamps Approx. 15
Total in Kgs 329.06

Note
1. The weights mentioned are subject to tolerance as per IS
2. The weights mentioned are before drilling of holes
BILL OF MATERIALS – 10

For UG Cable network (Having 3 Nos H Frame with Transformer seating and seating angle support x-

Length Qty (in


Sl No Size of the steel section Kgs/Mtr Total Wt
(in mm) Nos)
TOP Bracket
1 100x100x8mm MS Angle 850 5 12.1 51.43
2 75x40x4.8mm MS Channel (MC75/MCP75) 2400 4 7.14 68.54
3 45x45x5mm MS Angle 850 5 3.4 14.45
4 75x40x4.8mm MS Channel (MC75/MCP75) 1040 2 7.14 14.85
5 50x50x6mm MS Angle 2000 2 4.5 18
6 50x50x6mm MS Angle 1000 2 4.5 9
7 65x65x6mm MS Angle 1440 2 5.8 16.7
Transformer Center
8 130x130x12mm Angle 1110 1 23.4 25.97
9 100x50x5mm MS Channel (MC100/MCP100) 1200 2 9.56 22.94
10 130x130x12mm MS Angle (with side plate) 1110 2 23.4 51.95
11 75x75x6mm MS Angle 1750 2 6.8 23.8
12 65x65x6mm MS Angle 1260 2 5.8 14.62
13 75x40x4.8mm MS Channel (MC75/MCP75) 1110 2 7.14 15.85
GOS Mounting Structure (Ladder)
14 45x45x5mm MS Angle 1640 6 3.4 33.46
15 45x45x5mm MS Angle (Cleat) 60 18 3.4 3.67
16 40x40x5mm MS Angle 335 6 3 6.03
Round clamps of different sizes made out of MS flats
suitable for fixing the above structural materials to the
pole.
a) 75x10 MS Flat 1000 2 5.89 11.77
17 b) 75x6 MS Flat 1000 8 3.53 28.26
MS Hexagonal bolts, nuts and washers of different 17kgs
18 sizes to sufficient in quantity for fixing clamps Approx. 17
Total in Kgs 448.3
Note
1. The weights mentioned are subject to tolerance as per IS
2. The weights mentioned are before drilling of holes
BILL OF MATERIALS – 11
For OH line (Having Single H Frame without Transformer seating and seating angle support x-arm)

Length Qty
Sl No Size of the steel section Kgs/Mtr Total Wt
(in mm) (in Nos)
TOP Bracket
1 100x100x8mm MS Angle 850 3 12.1 30.86
2 75x40x4.8mm MS Channel (MC75/MCP75) 2400 2 7.14 34.27
3 45x45x5mm MS Angle 850 3 3.4 8.67
4 75x40x4.8mm MS Channel (MC75/MCP75) 1040 2 7.14 14.85
5 50x50x6mm MS Angle 1000 2 4.5 9
6 50x50x6mm MS Angle 1000 2 4.5 9
7 65x65x6mm MS Angle 1440 2 5.8 16.7
GOS Mounting Structure (Ladder)
8 45x45x5mm MS Angle 1640 2 3.4 11.15
9 45x45x5mm MS Angle (Cleat) 60 6 3.4 1.22
10 40x40x5mm MS Angle 335 2 3.002 2.01
Round clamps of different sizes made out of MS flats
suitable for fixing the above structural materials to the
pole.
11 a) 75x6 MS Flat 1000 6 3.532 21.19
MS Hexagonal bolts, nuts and washers of different 10kgs
12 sizes to sufficient in quantity for fixing clamps Approx. 10
Total in Kgs 168.93
Note
1. The weights mentioned are subject to tolerance as per IS
2. The weights mentioned are before drilling of holes
BILL OF MATERIALS – 12
For UG Cable network (Having 3 Nos H Frame without Transformer seating and seating angle support x-
arm) for 11 mtr Spun Pole for 63/100/250/500 KVA Transformer.

Length Qty
Sl No Size of the steel section Kgs/Mtr Total Wt
(in mm) (in Nos)
TOP Bracket
1 100x100x8mm MS Angle 850 5 12.1 51.43
2 75x40x4.8mm MS Channel (MC75/MCP75) 2400 4 7.14 68.54
3 45x45x5mm MS Angle 850 5 3.4 14.45
4 75x40x4.8mm MS Channel (MC75/MCP75) 1040 2 7.14 14.85
5 50x50x6mm MS Angle 2000 2 4.5 18
6 50x50x6mm MS Angle 1000 2 4.5 9
7 65x65x6mm MS Angle 1440 2 5.8 16.7
GOS Mounting Structure (Ladder)
8 45x45x5mm MS Angle 1640 6 3.4 33.46
9 45x45x5mm MS Angle (Cleat) 60 18 3.4 3.67
10 40x40x5mm MS Angle 335 6 3 6.03
Round clamps of different sizes made out of MS flats
suitable for fixing the above structural materials to the
11 pole
a) 75x6 MS Flat 1000 8 3.53 28.26
MS Hexagonal bolts, nuts and washers of different sizes 10kgs
12 to sufficient in quantity for fixing clamps Approx 10
Total in Kgs 274.39
Note
1. The weights mentioned are subject to tolerance as per IS
2. The weights mentioned are before drilling of holes
Special Locality Allowance:

Locality allowance at the rate noted below is given over and above the schedule
of labour for the listed areas.
Percentage
Name of As
Sl. No. Area over &
ESCOM Existing
above SR
Davanagere District:
20 20
Channagiri, Honnalli Taluks

Tumkur District:
15 15
Pavagada Taluk.
1 BESCOM
All Divisions coming under Bangalore Metropoliton Area 30
30
Zone

Anekal, Chandapura, Hosakote & Devanahalli. In BRAZ 20 20

South Kanara District: Bantwala, Mangalore, Sulya,


45 45
Puttur, Belthangadi Taluk

Udupi District: Udupi, Kundapura, Karkala Taluk 45 45

Chickmagalur District:,Chichmagalur, Koppa, Mudigere, 45


35
Narasimharajapura, Sringeri Taluk

2 MESCOM 35
Chickmagalur District:,Kadur, Tarikere Taluk NEW

Shimoga District: Hosanagara, Thirthalli, Sagara, Taluk 35 45

35
Shimoga District: Soraba, Shikaripura 35

Shimoga District: Shimoga, Bhadrawathi,Taluks 25 25

Dharwad District:
30
a) Kalghatagi 30
20
b)Dharwad Taluk 20

Haveri District:
30
a)Hanagal,Herikerur 30
20
b)Byadagi,Shiggon,Savanur Taluks 20

Belgaum District:
3 HESCOM 20 20
Hukkeri, Belgaum,Bailahongala Soundathi Taluks

Belgaum District:
20 45
Khanapura Taluk

Uttar Kannad District:


Modified as
Karwar,Joida, Haliyal,Sirsi,Mundagod,Yellapur,Bhatakal, 40
below
Sidapur,Honnavar,Kumta and Ankola.

Uttar Kannad District:


NEW 45
Kodagu District:
40 40
Madikeri, Virajpet, Somwarpet Taluks

Mysore District:
30 30
H.D.Kote, Hunsur and Piriyapattana

4 CESCO Chamaraj Nagar District:


30 30
Gundlupet, Chamarajanagar, Kollegal Taluk

Chamaraj Nagar District:


NEW 15
BR Hills in Yalandur Taluk
Hassan District:
40 40
Sakaleshpura, Hassan, Arakalagudu, Belur, Alur.
Taluks:
Raichur, Koppal, Bellary, Gangavathi, Sandur, Manvi, 15 15
5 GESCOM Sindhanur, Shahapur, Jewargi, Sedam

Taluks: Surpur, Devadurga New 25

Note: In case of civil works where KPWD SR rates are adopted, the locality
allowance as applicable in KPWD SR shall be followed.