PREPARING FOR 7MTT TRANSITION :

IDENTIFYING WORKLOADS :

When You select volumes and configuration that you want to transition how it affects clients

Granularity of transition operation


ACCESSING THE 7MTT TRANSITION TOOL:
Accesing 7MTT through web interface and cli in Windows and Linux only cli :

The collect and access feature is available on Window only for Copy based transition, for copyfree
transition you work offline or use inventory collect tool :
Credential of system

Offline Assesment and generate the combined report :


When the information from the Host is collected 7mtt compare device driver data against
intercompatibilty tool data : give it is compatible or not compatible :

7mtt also gives information whether device driver of the host is compatibile with cluster mode / not :
If the drivers is compatible, the 7mtt will says whether device is with latest version / not

7mtt doesn’t connect to imt online but it has build in version for these analysis.

7mtt check and provide the required version of Microsoft multipathing I/o drivers, host bus adapters
drivers, firmware and bios.

7mtt 2.2 where can import the latest IMT which we have to download from the site.

 When you evaluate Transition feasibility, the level of details will come across that there are
number of differences between feature and functionality. The comparision is see overwhelming
but the goal is surprises
 Collect and Tool access feature surprise you with all possible differences. The details are similar
as you see in 7MTT migration precheck
 To see these details, you can look at summary precheck in workbook

Below are the LIMITATION


Option default setting changing in dataontap
Collect and Assess Workbook : provide information of snapmirror and snapshot
INVENTORY COLLECT TOOL IS STANDALONE TOOL FOR COLLECTING CONFIGURATION AND
INVENTORY INFORMATION ABOUT 7MODE STORAGE CONTROLLER, HOST AND APPLICATION
SO
YOU CAN TEST THE TRANSITION READINESS OF THE SYSTEM.
USE THE INVENTORY COLLECT TOOL DURYING TRANSITION PLANNING TO INFORM TO ALL
STAKE HOLDERS ABOUT DETAIL OF CONTROLLER THAT RUNNING DATA ONTAP 7MODE, AND
WINDOWS, LINUX AND VMWARE HOST
WE CAN USE INVENTORY COLLECTION TOOL GUIDE FOR TRANSITION ASSESMENT TO COLLECT
THE REQUIRED INFORMATION THE GUIDE ALSO HELP TO COLLECT THE REQUIRED
INFORMATION FROM THE SYSTEM
TRANSITION ASSESMENT SUMMARY AND TRANSITION ASSESMENT WORKBOOK ARE
GENERATED IN XML FORMAT :
7 MODE 2.2 COPY BASED TRANSITION GUIDE WILL GUIDE HOW TO IMPORT THE INVENTORY
REPORT YOU CREATED FOR CONTROLLER AND HOST

ALSO GUIDE HOW TO ACCES THESE CONTROLLER AND HOST

HOW TO VERIFYT THAT THEY ARE READY FOR TRANSITION

IF YOU ARE PLANNING COPY FREE TRANSITION YOU USE THE REPORT GENERATED BY
INVENTORY COLLECT TOOL PAIR THE SYSTEM IN THE PROJECT
THAT IS DONE
YOU CREATE THE TRANSITION PROJECT IN 7MTT FOR COPY FREE TRANSITION

RUN THE BELOW COMMAND FROM WINDOW HOST WHERE INVENTORY COLLECT TOOL IS
INSTALL AND LIST THE WINDOWS HOST
RUNNING THE ICT TOOL

GENERATE THE INVENTORY REPORT RUN THE ICT COMMAND WITH SYSTEM IP ADRESS AND
CREDENTIAL

RUN THE ICT TOOL FROM ONE OF TWO WAY


YOU CAN SPECEIFY THE SYSTEM
TYPE THE NAME YOU WANT TO PROVIDE FOR INVENTORY REPORT
NEXT SPECEIFY THE SYSTEM TYPE
FOR E.G DAT ONTAP 7MODE THE SYSTEM TYPE IS ONTAP
FOR HOST LINUX SYSTEM TYPE IS LINUX
PROVIDE SYSTEM CREDENTIAL
PROVIDE IPADRESS / HOSTNAME OF CONTROLLER OR HOST

SECOND WAY :

PROMPTED TO ENTER TEXT FILE AT THE COMMAND LINE:


7 mode ABLE TO USE SNAPMIRROR TECHNOLOGY :
ENABLE THE SNAPMIRROR FUNCTIONALITY

ENABLE THE ACESS TO ALL OR INTER CLUSTER LIF ON CLUSTER


IF THE SNAPMIRROR.ACCESS OPTION IS LEGACY
AND SNAPMIRROR.CHECK.IP OPTION IS OFF

ENTER SVM NAME TO /etc/snapmirror.conf file

EXPAND THE 32-BIT AGGREGATE TO 64-BIT AGGREGATE BEFORE GOING TO CLUSTER MODE :
GUIDE IS THERE : TO SEE HOW WE CONVERT
After you configure SP, verify that SP is online

Use 7mode Snapmirror licence of 7mode same to Cluster system.


BEFORE WE START THE MIGRATION THERE ARE ADDITIONAL PREPARATION :

1. ADD THE SNAPMIRROR LICENSE :

2. ENABLE SNAPMIRROR :

3. ENABLE THE SYSTEM TO COMMUNICATE WITH TARGET CLUSTER


4. VERIFY THE SNAPMIRROR IS AUTHORIZE ON ALL INTERFACES

5. IF YOU ARE RUNNIG DATA ONTAP VERSION 7.3.7 OR 8.0.3/8.0.1


AND USING E0M AS MGMT IP ADDRESS TO INTERACT WITH 7MTT ALLOW DATA TRAFFIC
ON E0M INTERFACE :

6.
DISABLING THE VOLUME OPTION DOESN’T AFFECT ANYTHING ELSE :
7. THERE SHOULD BE NO OFFLINE VOLUME, AND AGGREGATE AND THERE SHOULD BE NO
HARDWARE FAILURE IN 7MODE :

PREPARING THE CLUSTER STORAGE :

IT SHOULD NOT BE IN TAKEOVER MODE


Transition of data volume contain several phases :

1. Preparation
2. Datacopy
3. Precutover
4. Cutover

Durying the preparation phase you use the 7MTT to create transition session.
Use the tool to collect information about Data ontap 7mode, Cluster ontap systems,
Volumes and ip adresses

The tools then run transition precheck in preparation of Data copy operation.
The cluster volume is created as readonly volume

The tools collect the cluster at SVM information and add them to transition session
The tool also add the collected IP addresses to the SVM.

DATACOPY PHASE OF TRANSITION OF STANDALONE VOLUME

Copies data to cluster created during preparation stage.


Then disable administrative acess to cluster data ontap volumes
The tools creates the peering betwwen 7mode and cluster mode
Then snapmirror established between 7mode volume and cluster mode volumes
Cluster data ontap volume is periodically having the data with 7mode volumes
Edit this Scheduled is there for Snapmirror update, resync and baseline transfer = create
data copy schedule
To manage the copy operation for all the volumes that we selected for operation we can
defined multiple data copy scheduled
The copy scheduled composed of detailed such as starttime
You can provide limit for multiple concurrent transfer
And throtlle for different periods such as week day, weekend, bussiness hour, non
bussiness hours and disaster recovery scenario
Define maximum of 6 schedule for subproject, but these schedules are not to overlapp

To trigger Ondemand update click on update button reduce the data delta between
7mode and cluster mode