Technical specification
General Coupling A Coupling B
All seams and other joining works GIA SwedVent ZIP-joints GIA SwedVent steel clamps
are fully welded (vulcanised) 40 mm Both duct ends made with a split One end of each duct length is fitted
wide. No sewing. Suspension hooks zipper (plastic zipper) of heavy duty with a steel ring, vulcanised to the
are welded to the fabric at a distance PVC-type. Protection-sleeve which fabric. One steel clamp made of
of c/c 0,75 m. On duct diameters on the outside hides the zipper and galvanized 1,5 mm steel with locking
>Ø1800 mm, two parallel lines of on the inside seals the joint according device (threaded crank) closes the
suspension hooks are mounted. to the principle ”the higher pressure joint.
Every duct length is marked with the tighter joint”. With ZIP-joints,
information regarding quality, length, the ducting is delivered on standard
diameter, max allowed working pallets regardless diameter.
pressure and manufacturing date.
DIAMETER (mm) Max allowed working pressures (kPa) valid for new ducting. Safety factor 3.
400 98,0 64,4 98,0 64,4
500 78,4 51,5 78,4 51,5
600 65,3 42,9 65,3 42,9
700 56,0 36,8 56,0 36,8
800 49,0 32,2 49,0 32,2
900 43,6 28,6 43,6 28,6
1000 39,2 25,8 39,2 25,8
1100 35,6 23,5 35,6 23,5
1200 32,7 21,5 32,7 21,5
1300 30,2 19,8 30,2 19,8
1400 28,0 18,4 28,0 18,4
1500 26,1 17,1 26,1 17,1
1600 24,5 16,1 24,5 16,1
1700 23,1 15,2 23,1 15,2
1800 21,8 14,3 21,8 14,3
2000 19,6 12,9 19,6 12,9
2200 17,8 11,7 17,8 11,7
2400 16,3 10,7 16,3 10,7
2500 15,7 10,4 15,7 10,4
2600 15,1 9,9 15,1 9,9
2800 14,0 9,2 14,0 9,2
3000 13,1 8,6 13,1 8,6
Note: All specifications are subject to changes without notification.
GIA SwedVent Repair Sleeve
The repair sleeve is a fast and secure tool for repairing holes and tears of flexible ducting. The sleeve is
made from standard duct material and a longitudinal zipper is attached for closing the sleeve. The sleeve
is made approx 0.5% smaller than the nominal duct diameter which will allow the sleeve to be really tight
against the duct once the duct is pressurized. With the repair sleeve, the repair will be professionally done
and the leakage from any hole will be reduced to a minimum. The repair sleeves are manufactured in
standard lengths 1.0, 2.0, 3.0 and 5.0 m. Other lengths will be manufactured upon request.
Determine the length of the hole. The repair Unhook the suspension hooks which will be
sleeve should cover the hole with at least 0.5 covered by the repair sleeve.
m margin.
Wrap the repair sleeve over the duct. Make Cut a hole in the repair sleeve for each
sure the hole is well covered by the sleeve suspension hook using a knife.
and the zipper is at least 0.5 m away from the
hole.
Pull the suspension hooks through the holes Close the zipper and the repair is finished.
and hook them back onto the suspension
cable.
Standard technical specifications GIA SwedVent high pressure tunnelling fans with accessories
FANS
FAN MODEL AVH63 AVH71 AVH90 AVH100 AVH112 AVH125 AVH140 AVH160 AVH180 AVH224
Motor F-class, IP54, 400/440 V, 50/60 Hz
Nominal 45-160 45-160 75-315 132-500
9-25 kW 11-37 kW 37-90 kW 45-110 kW 9-37 kW 132-500 kW
power kW kW kW kW
Impeller 1000/1200
3000/3600 rpm 1500/1780 rpm
speed rpm
Bearings SKF
Bearing
SKF “auto-lubricators system 24” on casing outside
lubrication
Ø1000
Ø380 Ø380 mm, Ø560 mm, Ø560 mm, Ø560 Ø800 Ø800 mm Ø800 mm,
mm, Ø1000 mm,
Impeller hub mm, cast welded welded welded mm, cast mm, cast welded welded
welded welded steel
aluminium steel steel stee aluminium aluminium steel steel
steel
Impeller 10 pcs, cast aluminium, adjustable at
8 pcs, cast aluminium, adjustable at stillstand
blades stillstand
Gap between
blade top
1,5 mm 1,5 mm 1,5 mm 1,5 mm 2,0 mm 2,5 mm 2,5 mm 3,0 mm 3,0 mm 3,0 mm
and fan
casing
Casing inner
630 mm 710 mm 900 mm 1000 mm 1120 mm 1250 mm 1400 mm 1600 mm 1800 mm 2240 mm
Ø
Fan casing
5 mm 5 mm 6 mm 6 mm 6 mm 6 mm 8 mm 8 mm 8 mm 10 mm
thickness
Casing
antirust 60 μ acryl primer + 100 μ acryl top layer
protection
laser-cut,
Casing
8x50 mm, laser-cut, 10x60 mm, welded laser-cut, 10x70 mm, welded
flanges
welded
Turbulence
Guide vanes welded to inside casing + 5 straight longitudinal “fins”
elimination
CE-marking yes
Performance
full test before delivery, capacity measure-ments
test
Allowed
< 2mm/s
vibrations
SILENCERS
MODEL GS63 GS71 GS90 GS100 GS112 GS125 GS140 GS160 GS180 GS224
Inner Ø 630 mm 710 mm 900 mm 1000 mm 1120 mm 1250 mm 1400 mm 1600 mm 1800 mm 2240 mm
Outer Ø 790 mm 870 mm 1060 mm 1160 mm 1280 mm 1410 mm 1560 mm 1760 mm 1960 mm 2400 mm
Length 1000 mm 1000 mm 1200 mm 1200 mm 1200 mm 2000 mm 2000 mm 2400 mm 2400 mm 3000 mm
Casing
laser-cut, 8x70 mm, welded laser-cut, 8x80 mm, welded
flanges
Casing
3 mm 3 mm 3 mm 3 mm 3 mm 3 mm 4 mm 4 mm 4 mm 5 mm
thickness
Sound absorbing material Heavy mineral wool
Self supporting to fan casing yes
Casing antirust protection 60 μ acryl primer + 100 μ acryl top layer
centre
baffle,
“Super centre baffle, l=800 centre baffle, l=1800 centre baffle, l=2200
centre baffle, l=1000 mm, Ø550 mm l=2500
silencer” mm, Ø380 mm mm, Ø640 mm mm, Ø640 mm
mm, Ø640
mm
INLET BELLS
MODEL GS63 GS71 GS90 GS100 GS112 GS125 GS140 GS160 GS180 GS224
Intake "Bell shaped", pressure turned
Casing
2 mm 3 mm
thickness
Protection
grille “spider
net model
DUCT ADAPTERS
MODEL GS63 GS71 GS90 GS100 GS112 GS125 GS140 GS160 GS180 GS224
Length 150 mm 150 mm 150 mm 150 mm 150 mm 150 mm 200 mm 200 mm 200 mm 200 mm
Casing
3 mm 4 mm
thickness
Ø9 mm ring welded to adapter end for securing ducting
FREQUENCY INVERTERS
DAHLANDER STARTERS