Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Diseño de Columnas de Concreto Basado en ACI 318-14

INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH fc' = 6 ksi
REBAR YIELD STRESS fy = 60 ksi
SECTION SIZE Cx = 40 in
Cy = 36 in

FACTORED AXIAL LOAD Pu = 1700 k


FACTORED MAGNIFIED MOMENT Mu,x = 1800 ft-k
Mu,y = 100 ft-k
FACTORED SHEAR LOAD Vu,x = 130 k THE COLUMN DESIGN IS ADEQUATE.
Vu,y = 150 k
COLUMN VERT. REINFORCEMENT 8 # 8 at x dir.
(Total 22 # 8)
3 # 8 at y dir.
LATERAL REINF. OPTION (0=Spirals, 1=Ties) 1 Ties
LATERAL REINFORCEMENT 4 legs,# 4 @ 12 in o.c., at x dir.
3 legs,# 4 @ 12 in o.c., at y dir.

ANALYSIS
5000
4500
4000
e
3500
3000
f Pn (k) 2500
2000
e
1500
1000
500
0
0 500 1000 1500 2000

f Mn (ft-k)

f Pn (k) f Mn (ft-k)

2 0.85 f '
C 
eo = , E c = 57 , E s = 29000ksi
'
AT AXIAL LOAD ONLY 4315 0 f C
AT MAXIMUM LOAD 4315 41 Ec
AT 0 % TENSION 523 52    e   e 2
AT 25 % TENSION 412 72 
0.85 f
'
2  c    c   , for 0  e c  e o
=   e o   e o  
C
AT 50 % TENSION 312 83 f C

AT e t = 0.002 147 93 

0.85 f , for e c  e o
'
C
AT BALANCED CONDITION 139 94
AT e t = 0.005 e s E s , for e s  e t

0 208 f =
S
 f , for e s  e t
AT FLEXURE ONLY 0 208  y

CHECK FLEXURAL & AXIAL CAPACITY


f Pmax =F f [ 0.85 fc' (Ag - Ast) + fy Ast] = 4315 kips., (at max axial load, ACI 318-14 22.4)
where f = 0.65 (ACI 318-14 21.2) > Pu [Satisfactory]
2
F = 0.8 Ag = 1440 in Ast = 17.38 in2

0.75 + ( et - 0.002 ) (50), for Spiral


f= = 0.656 (ACI 318-14 21.2)
0.65 + ( et - 0.002 ) (250 / 3), for Ties

where Cb = d ec / (ec + es) = 22.2 in et = 0.0021 ec = 0.003


d = 37.5 in, (ACI 20.6) D = 40.0 in Cover = 1.5 in, (ACI 318 20.6.1)
f Mn = 48 ft-kips @ Pu = 1700 kips > Mu = 1803 ft-kips [Satisfactory]
rmax = 0.08 (ACI 318-14 10.6) rprovd = 0.012
rmin = 0.01 (ACI 318-14 10.6) [Satisfactory]

CHECK SHEAR CAPACITY (ACI 318-14 10 & 22.5)


f Vn = f (Vs + Vc) (ACI 318-11 22.5)
> Vu [Satisfactory]
where f = 0.75 (ACI 318-11 21.2) fy = 60 ksi
d A0 Av Vc = 2 (fc')0.5A0 Vs = MIN (d f y Av / s , 4Vc) f Vn
x 37.4 147 0.80 22.8 91.1 85
y 33.4 147 0.60 22.8 91.1 85

smax = 16 (ACI 318-14 25.7) sprovd = 12 in


smin = 1 [Satisfactory]