CHELTON (ELECTROSTATICS) LIMITED

OVERHAULMANUAL
PUBLICATION No 16-434

BLADE ANTENNA
TYPE 16-434

OVERHAUL MANUAL

This Manual complies with British


Civil Airworthiness Requirements.
Section A, Chapters A6-2. The
technical accuracy of this manual
has been verified and certified
correct

Signed/?/d&& c

*Date: 10th November 1992

CAA Design Approval No DAI/2613/48

CHELTON (ELECTROSTATICS) LIMITED


FieldhouseLane Marlow Buckinghamshire SL7 1LR England
Telephone: 0628 472072 Telex: 849363 Fax. 0628 482266

23-I 2-43 Nov l/92


SHELTON (ELECTROSTATICS) LIMITED
OVERHAULMANUAL
PUBLICATION No 16-434

Incorporated under CAA Design Approval No. DAI/2613/48

Retain this record of Temporary Revisions at the front of the manual immediately
following the Record of Permanent Revisions. On receipt of the Temporary Revision,
revise as detailed in the letter of transmittal and record the incorporation of the
revision or amendment on this sheet. The introduction of data by temporary revision
or amendments not certified in accordance with British Civil Airworthiness
Requirements Chapter AS-3. will invalidate the initial certification on the title
page of the manual relative to the part revised. Temporary revisions or amendments
which have been certified by the approved Design Organisation other than that
applicable to the initial certification must be recorded on separate record sheets.

Cancelled
Temporary Revision Insertion
Number Date BY Date

Record of Temporary Revisions


Page 1
23-I 2-43 Nov l/92
CHELTON (ELECTROSTATICS) LIMITED
OVERHAULMANUAL
PUBLICATION No 16-434
RECORDOF PERMANENTREVISIONS

Incorporated under CAA Design Approval No. DA112613148

Retain this record of Permanent Revisions at the front of the manual immediately
following the title page. On receipt of the Permanent Revision, revise as detailed
in the letter of transmittal and record the incorporation of the revision or amendment
on this sheet. The introduction of data by permanent revision or amendments not
certified in accordance with British Civil Airworthiness Requirements Chapter A5-
3, will invalidate the initial certification on the title page of the manual relative
to the part revised. Permanent revisions which have been certified by the approved
Design Organisation other than that applicable to the initial certification must be
recorded on separate record sheets.

Permanent Revision Insertion Entered


Number Date BY

Record of Permanent Revisions


Page 1
23-l 2-43 Nov l/92
CHELTON (ELECTROSTATICS) LIMITED
OVERHAULMANUAL
PUBLICATION No 16-434

SERVICE
B%.LETIN US2

Service Revision Date Incorporated


Bulletin Number Incorporated BY
Number in Manual

Service Bulletin List


Page 1
23-I 2-43 Nov l/92
CHELT~N (ELECTROSTATICS) LIMITED
OVERHAULMANUAL
PUBLICATION No 16-434
LIST OF EFFECTIVE PAGES
SUBJECT

Title Page ... ,.. ... ... ... ... Nov l/92

Record of Permanent Revisions ... ... ... Page 1 Nov l/92

Record of Temporary Revisions ... ... ... Page 1 Nov l/92

Service Bulletin List .,. ... ... ... Page 1 Nov l/92

List of Effective Pages . . . ... ... ... Page 1 Nov l/92

Table of Contents ... ... ... l . . ... Page 1 Nov l/92

Text and Illustrations ... ... . . . ... Page 2 Nov l/92


Page 3 Nov l/92
Page 4 Nov 1192
Page 5 Nov l/92
Illustrated Parts List ... ... . . . ,.. Page 1001 Nov l/92
Page 1002 Nov l/92
Page 1003 Nov l/92

List of Effective Pages


Page 1
23-l 2-43 Nov l/92
CHELTON (ELECTROSTATICS)LIMITED
OVERHAULMANUAL
PUBLICATION No. 16-434
OF CONTENTS

Para.

Description. Operation. Data ... ... ... ... ... ... 1

Disassembly ... ... ... ... ... ... ... 2

Cleaning ... ... *,. ... ..* ... ... 3

Inspection/Check ... ... ... ... ... .. . ... 4


Repair ... ... f.. *. . ... ... ... 5

Assembly ... ... ... ... ... ... ... 6

Fits and Clearances ... ... ... ... ... ... ... 7

Testing ... ... ... ... ... . .. ... 8

Trouble Shooting ... ... ... ... ... ... ... 9

Storage Instructions ... ... ... ... ... ... ... 10

Special Tool, fixtures and equipment ... ... .., ... ... 11

Illustrated Parts List ... ... ,.. ... ... ... ... 12

Table of Contents
23-l 2-43 NovP%;9i
CBELTON (ELECTROSTATICS) LIMITED
OVERHAULMANUAL
PUBLICATION No. 16-434

Figure 1 - Blade Antenna Type 16-434

Page 2
23-l 2-43 Nov lo/92
CHELTON(ELECTROSTATICS) LIMITED
OVERHAUL MANUAL
PUBLICATION No. 16-434

1. DESCRIPTION OPERATIONDATA

A. Description and Operation (Ref Figure 1)

The antenna type 16-434 is a low height passive antenna designed to function
inboth communications and homing applications over the frequency range 118 MHz
to 174 MHZ.

Theantennaisdesignedasatoploadedmonopole fedviaa reactance compensation


network to enhance gain at the lower operating frequencies. Compliance with
the impedance specification is achieved using frequency dependent resistive
loading.

The antenna comprises a pressure moulded GRPshell of raked aerodynamic form,


to which is attached a stainless steel leading edge strip and a top loading
tube. The unit is closed by an aluminium alloy baseplate which supports the
single RF connector, matching circuitry and includes the six hole fixing for
airframe mounting.

B. Data

Equipment: Blade Antenna type 16-434

Frequency range: 118 to 174 MHz

Impedance: 50 Ohms (nominal)

VSWR: Not greater than 2.5:1

Isolation: Not applicable

Radiation: Azimuth - Omnidirectional (nominal)


Elevation - As stub

Gain (beam pk): 118 MHz 2 -15 dBi


136 MHz 2 -10 dBi
152 MHz 2 -5 dBi
174 MHz 2 -2 dBi

Polarisation: Vertical (when mounted vertically)

Connector: 16-434: N (female)


16-434T: TNC (female)

Dimensions: 280 mm (11 ins) x 51 mm (2 ins) x


204 mm (8 ins) maximum (excluding connector)

Weight: 380 g maximum

Paint finish: White gloss epoxy to DTD 5555


Black matt epoxy to DTD 5555 (suffix P4)
e.g. Matt black unit: 16-434P4

234243 Nov%9if
CHELTON (ELECTROSTATICS)LIMITED
OVERHAULMANUAL
PUBLICATION No. 16-434
2. DISASSEMBLY

The blade antenna cannot be dismantled.

3. CLEANING

Clean all parts with industrial methylated spirits. any alcohol based cleaning
solvent or recognised printed circuit board cleaning agent.

gEg: Do not use commercial blue pigmented spirits. corrosive or flammable


cleaning agents.

4. INSPECTION/CHECK

A. Inspect all metal parts for:

(1) Cleanliness
(2) Corrosion
(3) Distortion
(4) Denting
(5) Cracks

B. Make detailed inspection of:

(1) Fixing holes for elongation


(2) Baseplate for cracking. particularly around the fixing holes
(3) Connector for security, and evidence of damage to center contact and body

5. REPAIR

Electrical repairs are not possible.

Repair is limited to local restoration of the protective finish using an epoxy


gloss white paint to DTD 5555 (matt black for 16-434P4).

6. ASSEMBLY- not applicable

7. FITS AND CLEARANCES- not applicable

8. TESTING

The following test procedure requires the use of the following test equipment.

(1) Chelton Test Set QB8

(2) Flat metal ground plane 4 ft x 8 ft minimum.

Prior to each test and at intervals of not more than 30 minutes during the test,
calibrate the test equipment in accordance with the test set manual.

23-j 2-43 Novp%9:


CHELTON (ELECTROSTATICS) LIMITED
OVERHAULMANUAL
PUBLICATION No. 16-434

A. VSWRMeasurement Procedure

(1) Mount the Unit Under Test (IJUT) centrally on the ground plane which should
be situated clear of any conducting projections.

(2) Set up the test equipment in accordance with the QB8 Test Set manual.

(3) Measure the VSWRrelative to 50 ohms at frequencies over the range 118 MHz
to 174 MHz.

(4) Verify that the VSWRmeasurements do not exceed the ratio stated below.

118 to 174 MHz: not greater than 2.5:1

9. TROUBLESHOOTING
No trouble shooting is required since the unit cannot be dismantled.

10. STORAGEINSTRUCTIONS

A. When available, use the manufacturers packing materials. If these are not
available, pack the unit as follows:

(1) Fit a protective cap over the connector.

(2) Place the unit in a suitable moisture resistant pack and seal.

(3) Attach a label to the storage pack providing the following information:

(a) Unit type and serial number


(b) Date of last maintenance/overhaul check or receipt from the
manufacturer
(c) Date when unit is next to be tested
(d) Note of specific actions taken during maintenance/overhaul.

B. Storage life is unlimited. It is recommended that a unit in store be removed


and tested at a period not exceeding 3 years. A unit removed from storage,
irrespective of the period in store, must be tested before installation. Units
returned to storage must be inspected and tested in accordance with Testing
paragraph 8, and the record label revised.

11. SPECIAL TOOLS, FIXTURES AND EQUIPMENT

A. There are no special tools. fixtures or test equipment required to service this
equipment.

234 2-43 NovP$9:


mELToN (ELECTROSTATICS) LIMITED
OVERHAULMANUAL
PUBLICATION No. 16-434

ILLUSTRATEDPARTS LIST

BLADE ANTENNA

TYPE 16-434

NOTE: There is no spares support for the type 16-434 blade antenna
apart from the installation kit and RF gasket. No repairs
are permissible excepttotheprotective paint finish. Units
that fail to complywiththe performance as specified in this
Overhaul Manualmustbe returned to Chelton for evaluation.

234 Z-43 i::el%:


CHELTON (ELECTROSTATICS) LIMITED
OVERHAULMANUAL
PUBLICATION No. 16-434
12. DETAILED PARTS LIST

DRAINAGE SLOT ‘8’

FIT BUNGS TO DRAINAGE HDLE’A’ EITHER SIDE


OF SHELL. DRAINAGE SLOT9 TC BE KEPT CLEAR.

DRAINAGE SLOT’B TO BE BLOCKED OFF AND


DRAINAGE HOLE ‘A’ TO BE KEPT CLEAR.

Figure 1 - Blade Antenna Type 16-434

23-l 2-43 ~::el~~;;


CHELTON (ELECTROSTATICS) LIMITED
OVERHAULMANUAL
PUBLICATION No. 16-434
12. DETAILED PARTS LIST

TABLE 1

MARKERANTENNAPART No. 16-434

FIG PART NOMENCLATURE EFF UNITS


ITEM NUMBER 1234567 CODE PER ASSY

1-l 16-434 BLADE ANTENNA RF


8021-137 . INSTALLATION KIT (2 OFF BUNGS) 1
6930A/16-434 . RF GASKET 1

23-l Z-43 i%el$: