CENTRONIC II
1.00 - 1.12 version
CENTERMATIC
Ahe025-b.VP
PREFACE ........................................................................................................................... 5
WARRANTY CONDITIONS ............................................................................................. 5
® ®
TYPE- AND SERIAL NUMBER OF YOUR CENTRONIC /CENTERMATIC ............. 5
1 INTRODUCTION .......................................................................................................... 6
2 CONTROL PANEL ....................................................................................................... 7
® ®
3 CONNECTING THE CENTRONIC /CENTERMATIC ............................................. 8
4 BASIC INSTALLATION OF THE CENTRONIC ® ....................................................... 9
5 FERTILIZER SETTING FACTOR .............................................................................. 10
®
6 USE OF THE CENTRONIC ...................................................................................... 11
6.1 Schedule: use of the CENTRONIC ® ............................................................... 13
6.2 Programming of the CENTRONIC ® (Programming mode) .......................... 14
®
6.3 Operation of the CENTRONIC (Operation mode) ...................................... 28
6.3.1 Sequence AUTO-position ...................................................................... 30
6.3.2 Sequence HAND-position...................................................................... 31
6.3.3 Sequence ON BOARD COMPUTER-position ..................................... 32
®
6.4 Use of the CENTRASIDE ............................................................................... 33
®
6.5 Dynamic output check (CENTERMATIC ) ..................................................... 34
6.6 General instructions ......................................................................................... 36
6.7 Condensed instructions ................................................................................... 37
7 ERROR MESSAGES .................................................................................................. 38
Supplements
A TROUBLE SHOOTING ............................................................................................... 42
®
B ASSEMBLY OF CENTRONIC COMPONENTS ON TRACTOR ........................... 44
B.1 Mounting the forward speed sensor and code disc ........................................ 44
B.2 Socket.................................................................................................................... 45
B.3 Assembly of the control box ............................................................................... 45
B.4 Checking the forward speed sensor .................................................................. 46
C USE OF RADAR OR TRACTOR SENSOR .............................................................. 47
D ADJUSTMENT OF THE ACTUATOR ........................................................................ 48
E TABLE OF SETTING FACTORS ............................................................................... 51
4
This operator’s manual is meant for CENTRONICs II which have the 1.00 - 1.12 version of the
programme software.
L E LY CENTRONIC II
VERSION 1 . x x
Immediately after engaging the CENTRONIC* control system, this version number is shown on the
screen.
®
Version numbers as from 1.02 and thru can be used for a CENTERMATIC in combination with a
wheeled carriage.
If the serial number of the actuator control box starts with 057-…, 059-…, 063-… or higher, the
version number of the CENTRONIC II should be at least 1.08.
PREFACE
This Operator’s Manual is meant for personnel that are operating the machine and are responsible for its daily
maintenance.
Kindly read this manual fully prior to starting work.
Such instructions as are related to your safety and/or that of others are marked in the margin by a
warning triangle with exclamation mark. These instructions should be observed with particular care
and attention.
!
Instructions which may lead to serious material damage in case of non-compliance or incorrect use are
marked in the margin by an exclamation mark.
The machine described in this manual may be adjusted to specific regional conditions whilst they are also
subject to permanent research and innovation.
For this reason, the specifications of your machine may not be consistent with the pictures in this manual.
WARRANTY CONDITIONS
For those parts which fail in normal operating conditions the factory will make replacement parts available,
free of charge, for a period of 12 (twelve) months from the date of purchase.
Warranty shall not apply if the instructions mentioned in this manual have not been met, or if they have not
been met completely or correctly. Neither shall warranty apply in case of modification of the machine by you
or third parties without our foreknowledge and/or authorisation.
Type number
Serial number
6 1 INTRODUCTION
1 INTRODUCTION
The LELY CENTRONIC II is an electronic control system for setting the application rates of CENTERLINER
S/SL/SE/SX Fertilizer Spreaders.
The control system comprises of:
• an operator’s box (A, fig. 1) A
• a terminal block (B)
• an actuator control box (C)
• a forward speed sensor (E) with code disc
E
• an actuator (F) for controlling the feed
assembly C
• a sensor (G) for measuring the spinner disc ®
CENTRONIC II
speed.
The system may be extended with the LELY
G
CENTERMATIC weighing device*.
The CENTERMATIC weighing device is placed
between the tractor and the CENTERLINER B
spreader (or another machine). The trailed CEN-
TERMATIC weighing device is incorporated
into the carriage.
Depending on the model, the maximum admis-
® F
sible load is 3000 kg or 4300 kg. CENTERMATIC
The CENTRONIC control system automatically
adjusts the shutter position of the feed assembly 1
to the value which ensures the output required.
If the forward speed changes, the shutter position is adjusted automatically.
Without use of the CENTERMATIC weighing device, the shutter position is established on the basis of the
forward speed during spreading and of the data fed into the system. Such data may have been derived from the
output charts or may be the result of calibration tests.
The CENTERMATIC weighing device weighs permanently, also during driving. The shutter position is based
on the decrease of weight, as well as on the forward speed during spreading.
The CENTERMATIC weighing device brings about an adjustment of the shutter position if the output flow
changes. A discrepancy in the anticipated decrease of weight, caused by a change of output flow, is detected
immediately. The shutter position is then adjusted automatically.
Such application rates as have been adjusted may also be decreased or reduced (up to 50%) during spreading.
The CENTRONIC control system provides useful information such as:
• spinner disc speed;
• shutter position of feed device;
• forward speed;
• area worked;
• distance covered;
• weight of material applied (without CENTERMATIC: calculated/with CENTERMATIC: effective);
• weight of fertilizer in hopper (only when using CENTERMATIC).
The CENTRONIC can also be applied as an onboard computer for other types of equipment.
For speed measuring purposes, the (pulse) signal of a radar sensor or tractor speedometer can also be used (see
supplement C).
* Not fit for commercial purposes
2 CONTROL PANEL 7
2 CONTROL PANEL
A B C D
® ®
3 CONNECTING THE CENTRONIC /CENTERMATIC
When commissioning the CENTRONIC control system, or if an other tractor is going to be used, please be
referred to supplement B for fitting the fixation bracket of the operator’s box, the speed sensor and the code
disc.
C
A
®
CENTRONIC II
‚ •
CENTERMATIC®
3
! Make sure that the plugs are clean (no fertilizer) and dry before connecting them.
- Fit the operator’s box (A, fig. 3) of the CENTRONIC control system on the fixation bracket in the tractor
cab.
- Put the plug of the operator’s box into connection • of the plug block (B). Secure the plug onto the
connection by means of the securing ring.
- Put the plug of the actuator control box (C) into connection ‚ of the plug block or, if the CENTERMATIC
weighing device is used, into connection ƒ of the weight-angle measuring box (D) of the CENTERMATIC
weighing device. Secure the plug onto the connection by means of the securing ring.
- (If applicable:) Put the plug of the weight-angle measuring box (D) into connection ‚ of the plug block.
Secure the plug onto the connection by means of the securing ring.
Place the dust caps on the plug and connections after deplugging.
®
4 BASIC INSTALLATION OF THE CENTRONIC 9
®
4 BASIC INSTALLATION OF THE CENTRONIC
The CENTRONIC offers a choice of text display in the Dutch, English, French or German language. A c hoice
can also be made between the metric and imperial unitary system.
Commissioning procedure:
F
- Engage the CENTRONIC control system by means of the Power button (A). G
- Press the “Prog” button and the headland spreading button (B+C) at the
A B C D
same time (approx. 5 seconds) until the display below appears.
SELECT METRIC - Select the unitary system required and press the
U N I TARY enter button (this manual is based upon the
SYSTEM metric system).
IMPERIAL
The accuracy with which the output required is applied depends, to a large extent, upon the setting factor that
was programmed.
If the CENTRONIC control system is used together with the CENTERMATIC weighing device, any difference
between the pre-programmed setting factor and the effective factor will be adjusted automatically. Therefore,
a difference in the output rate can only occur at the early stage of the spreading operation.
If the CENTRONIC control system is used only, a difference between the pre-programmed setting factor and
the effective factor will lead to a constant, proportional discrepancy in the output rate.
For this reason it is recommended, if at all possible, to carry out an output check when you operate without the
CENTERMATIC weighing device. The output check takes place during programming of the CENTRONIC
control system in the position AUTO (C); see next page. You then ensure the correct setting factor for the
fertilizer you are going to spread.
If you establish a difference in your output rate while working, you can make an adjustment by changing the
setting factor proportionally. If, for instance, the output is 10% too high, the setting factor should be decreased
by 10%.
When using the CENTERMATIC weighing device, the setting factor listed in the chart is sufficiently accurate.
A discrepancy, if any, is put right automatically by the CENTRONIC control system .
If a reliable setting factor is not known, a dynamic output check is recommended. This check is carried out
during the first spreading pass and ensures that the correct setting factor is established quickly. Please refer to
®
“6.5 Dynamic output check (CENTERMATIC )” for further details.
®
6 USE OF THE CENTRONIC 11
®
6 USE OF THE CENTRONIC
The CENTRONIC offers the following application possibilities:
When using the CENTRONIC control system, a distinction is made between the programming mode and the
operation mode.
®
In the programming mode [please refer to “6.2 Programming of the CENTRONIC (Programming mode)”],
data such as setting factor, output rate, working width, etc., can be fed into the system and/or modified whilst
further other possibilities of operation (operating procedure) can be set.
The CENTRONIC control system registers all data of the previous operation. These parameters are used for
each new operation, unless you enter new data in the programming mode.
All operations of the CENTRONIC control system are carried out in the operation mode [please refer to “6.3
®
Operation of the CENTRONIC (Operation mode)”].
E
Put the CENTRONIC control system into operation by
pressing the Power button (A) once.
The screen (E) first displays information about the
CENTRONIC control system’s software. F
G
L E LY CENTRONIC II
A B C D
V E R S I O N 1.xx
After any button has been pushed, the CENTRONIC control system assumes the stand-by position of the
operation mode, or the programming mode, depending on the CENTRONIC control system’s mode during
previous operation.
The last screen that was shown at the moment the CENTRONIC control system was switched off will come up
first.
If the green light of the programming button (B) is burning, the CENTRONIC control system is in the
programming mode. If not, the operation mode is active.
Whenever you press a button which does not have a function (at that time), an acoustic signal is given.
®
6.1 Schedule: use of the CENTRONIC 13
®
6.1 Schedule: use of the CENTRONIC
• Do you operate in the OPEN/CLOSED position? • Use the power button (D) to open
YES
and close the shutters.
NO
• Press the arrow buttons (F) for data
display (Please refer to “6.3.3 Se-
• Do you operate in the ONBOARD COMPUTER YES quence ON BOARD ...”) .
position?
14 6.2 Programming mode
®
6.2 Programming of the CENTRONIC (programming mode)
The required adjustments can be set or selected by pressing the RH arrow buttons (G).
When setting a numerical value it is either increased or decreased.
The longer the arrow button is pressed, the faster the numerical value
changes. E
In this chapter such numerical values as are given by way of example are
rendered in italics. Obviously, you may select other values.
Whenever there is a possibility to choose, the selected value will blink.
F
G
The programming mode does not allow a return to a previous screen. When
you press the enter button (F), the adjustment is registered and the next A B C D
screen is displayed.
If you register an incorrect setting, the programming procedure first has to be finished. Then the procedure can
be re-started in order to put the incorrect setting right.
- Press the “Prog” button (B) in order to set the programming mode of the CENTRONIC control system. The
green light in the “Prog” button starts burning and the first screen appears.
- Adjust screen brightness by means of the RH arrow
ADJUST LIGHT
buttons.
SCREEN
When this first screen is shown, it is still possible to
BRIGHTNESS return to the operation mode by pressing the “Prog”
DARK
button. Press the enter button in order to continue
programming.
SET O P E N / C L O S E
O P E R ATING HAND - Select the operating procedure.
PROCEDURE If the CENTERMATIC weighing device is connected
AUTO ( C ) to the CENTRONIC control system, the choice “AUTO
(CM)” rather than “AUTO (C)” is displayed.
SET OUTPUT - Adjust the output rate to the value required and
R ATE 450 proceed to the next screen.
kg/ha
SET WORKING
WIDTH 24.0
- Select the working width required and proceed to
m
the next screen.
FORWARD SPEED YES - Select “YES” if the forward speed sensor needs
SENSOR TO BE calibrating.
C A L I B R ATED ? Select “YES” as well, if the sensor does not work or
NO if it was not installed.
Proceed to the next screen.
NO YES - Set the pulse counter at zero (0 impulse) by
selecting “START ANEW”. Drive exactly 20 m*
and press the upper RH arrow button (“END”).
DRIVE 20 m END Each pulse is accompanied by an acoustic signal.
AND PRESS END The display shows the number of pulses delivered
S TART by the sensor.
0 IMPULSE ANEW Proceed to the next screen.
* Drive in the field; driving on asphalt/concrete surfaces
may lead to discrepancies between 5 and 10%.
CHART TEST
ENTER
- Enter the setting factor and proceed to the next
SETTING 100
screen.
FACTO R
• ‚ ƒ
6.2 Programming mode: AUTO (C) position 17
• ‚ ƒ
(continued from programming mode)
"AUTO (C) position"
INTERRUPT
OPEN
- The actuator now opens the feed device.
The display shows how many seconds the check is
SHUTTER WILL BE still going to last.
OPEN FOR OUTPUT If need be, the check can be interrupted by pressing
T E S T F O R . . . . SECONDS the start/stop button (D), causing the immediate
closure of the feed device.
" See next page " - Select “YES” if you wish to carry out a second
output check.
• ‚
18 6.2 Programming mode: AUTO (C) position
• ‚
Such data as were entered into the position AUTO of the pro gramming mode, have now been stored in the
CENTRONIC control system’s memory. These data are retained, even after the CENTRONIC control system
is switched off.
All operations of the CENTRONIC control system take place in the operation mode.
Please be referred to “6.3 Operation of the CENTRONIC® (Operation mode)”.
6.2 Programming mode: HAND position 19
SET WORKING
WIDTH 24,0
- Select the working width and proceed to the next
m
screen.
Such data as were entered into the position HAND of the programming mode, have now been stored in the
CENTRONIC control system’s memory. These data are retained, even after the CENTRONIC control system
is switched off.
All operations of the CENTRONIC control system take place in the operation mode.
®
Please be referred to “6.3 Operation of the CENTRONIC (Operation mode)”.
6.2 Programming mode: OPEN/CLOSED position 21
All operations of the CENTRONIC control system take place in the operation mode.
®
Please be referred to “6.3 Operation of the CENTRONIC (Operation mode)”.
22 6.2 Programming mode: AUTO (CM) position
SET OUTPUT
R ATE 450 - Set the output rate at the required value and proceed
kg/ha to the next screen.
SET WORKING
WIDTH 24.0 - Select the working width and proceed to the next
m screen.
FORWARD SPEED DURING - The screen displays the minimum and maximum
SPREADING speeds for which the shutters can still be set at the
M I N I M U M 7,5 k m / h adjusted output rate.
M A X I M U M 18,6 km/h Proceed to the next screen.
Such data as were entered into the position AUTO of the programming mode, have now been stored in the
CENTRONIC control system’s memory. These data are retained, even after the CENTRONIC control system
is switched off.
All operations of the CENTRONIC control system take place in the operation mode.
®
Please refer to “6.3 Operation of the CENTRONIC (Operation mode)”
6.2 Programming mode: ONBOARD position 25
ADJUST
R AT E / Y I E L D 200 - Adjust the output rate at the value required - e.g. the
PER ha output of a spraying machine - and proceed to the
next screen. Since there may be a difference in units
(kg, litres etc.) these are not indicated.
SET
WORKING 21.0
- Set the required working width and proceed to the
WIDTH m
next screen.
Such data as were entered into the position ONBOARD COMPUTER of the pro gramming mode, have now
been stored in the CENTRONIC control system’s memory. These data are retained, even after the
CENTRONIC control system is switched off.
All operations of the CENTRONIC control system take place in the operation mode.
®
Please refer to “6.3 Operation of the CENTRONIC (Operation mode)”
6.2 Programming mode: ONBOARD position 27
SPREADER The system now enters the operation mode and the
CONNECTED adjacent screen is displayed.
- Press the “Prog” button and re-program the
RE-PROGRAM! CENTRONIC control system.
®
6.3 Operation of the CENTRONIC (Operation mode)
The CENTRONIC control system’s operation mode features a stand-by position and an operation position.
In the stand-by position, the CENTERLINER spreader’s shutters are E
closed. The light of the start/stop button (D) is not burning.
The day and total counters are immobile, with the exception of the counter
that registers the distance covered for the selected operation procedure
(AUTO( C/CM), HAND or ONBOARD COMPUTER).
F
In the operation position, the CENTERLINER spreader’s shutters are G
open. The light of the start/stop button (D) is burning.
The day and total counters of the selected operation procedure are A B C D
working.
After the CENTRONIC control system has been switched on, the opening screens showing the version number
are first displayed. After any key was pressed the CENTRONIC control system enters the stand-by position of
the operation mode or the programming mode.
- If the green light of the programming button (B) is alight, first scroll the programming procedure until it is
finished. As soon as the display for screen brightness adjustment comes up, you can return to the operation
mode by pressing the programming button.
- By means of the start/stop button (D) the stand-by position of the operation mode can be changed into the
operation position and vice versa.
In the operation mode, a sequence of screens displaying various data can be produced. Sequence display
depends on the operation procedure which you have selected.
sequence position AUTO (C/CM) (see “6.3.1 Sequence position AUTO”)
sequence position HAND (see “6.3.2 Sequence position HAND”)
sequence position ONBOARD COMPUTER (see “6.3.3 Sequence position ONBOARD COMPUTER)
Use the LH arrow buttons (F) for scrolling data sequences (vice versa).
During use of the position HAND, the shutter position setting is displayed on the RH side of the screen.
The sign ‘ indicates an intermediate position of the calibration scale.
XXX POS. OF
In the operation mode, the pre-programmed shutter
XXX SHUTTER
position can be increased or decreased by pressing the RH
XXX
arrow buttons (G). This adjustment can be made both in
XXX 5B'
the stand-by position and in the operation position.
XXX POS. OF
XXX SHUTTER
XXX
XXX 6A
If the CENTRONIC control system is used as an onboard computer for an other machine, the adjusted
output/yield is displayed on the RH side of the screen.
XXX 200
XXX /ha
XXX
XXX
When using the OPEN/CLOSE position, the display renders “SHUTTER CLOSED” or “SHUTTER OPEN” in
the stand-by position or operation position.
SHUTTER OPEN
The screen of any sequence which was last shown is first displayed when the operation mode is used anew.
30 6.3.1 Sequence position AUTO (Operation mode)
The CENTRASIDE headland spreading device itself should be operated in accordance with its relevant
Operator’s Manual.
If you are going to carry out headland spreading by tilting the CENTERLINER spreader, the outflow rate
remains the same. In that case, the CENTRONIC control system’s adjustment for full field spreading needs to
be maintained during headland spreading.
®
34 6.5 Dynamic output check (CENTERMATIC )
®
6.5 Dynamic output check (CENTERMATIC )
The aim of the dynamic output check is to establish the correct setting factor quickly.
This check is strongly recommended if a reliable setting factor of the fertilizer to be spread is not known,
especially if a minor output rate is required.
The starting- and final weight are established at the start of the spreading test and after having covered a
certain distance. The setting factor is calculated on the basis of the output and working width required, as well
as of the outcome of the check.
During programming the compliance with the suggested dynamic test may be affirmed or ignored:
If “YES” is selected during programming, the dynamic output check is started at the first switch from the
stand-by position to the operation position in the operation mode.
The following display then appears:
Observe the following instructions:
R E M A I N S TAT I O N A RY • Immobility of tractor (keep the engine running!).
THE STARTING WEIGHT • The hopper needs to contain sufficient fertilizer to
F O R T H E DYNAMIC SET- cover the distance required for the check.
TING TEST IS FIXED • Adjustment of the spreader at the prescribed
working height.
The initial weight is now established accurately.
After a maximum of 15 seconds the adjacent display
appears.
Start the first spreading pass.
0,0 km/h 450
As long as the distance required for the output test has
0 rpm kg/ha
not been covered, a double acoustic signal will sound
0.0 m
every 5 seconds in the operation position.
0A SHUTTER 100%
There is no need to stop immediately, once the
obligatory distance has been covered. The working
pass can be finished without any problem.
If you return to the stand-by position before the
obligatory distance has been covered, the display
DYNAMIC SETTING TEST
shows a (minimum) stretch still to be travelled.
STOPPED TOO SOON
Continue spreading in a following pass.
S P R E A D OVER ANOTHER
.... m The adjacent screen is displayed if you return to the
stand-by position after the obligatory distance (or
more) has been covered. Observe the following in-
structions:
R E M A I N S TAT I O N A RY
THE FINAL WEIGHT FOR • Immobility of tractor (keep the engine running!).
T H E DY N A M I C S E T T I N G • Adjustment of the spreader at the prescribed
TEST IS FIXED working height.
• No fertilizer replenishing at this stage.
®
6.5 Dynamic output check (CENTERMATIC ) 35
• A spinner disc speed of 430-470 rpm is obligatory for an output check in the AUTO (C) position. During
operations, the spinner disc speed should be maintained which is listed in the CENTERLINER spreaders’s
output charts for the relevant kind of fertilizer.
• Such parameters as are selected by the CENTRONIC control system in the AUTO (C) position during the
first output check (shutter position/duration) are based upon the data stored in the CENTRONIC control
system for basic kinds of fertilizer (setting factor 100).
The CENTRONIC control system calculates the setting factor by comparing the quantity measured with the
anticipated output if a fertilizer with setting factor 100 would have been used.
A second output check is carried out with the parameters based on the setting factor of the first test and
therefore gives increased output accuracy, especially if the setting factor is far removed from 100.
• If the CENTERMATIC weighing device is used, check the unladen weight of the spreader prior to fertilizer
application. If the weight is not exactly zero, you need to tare the machine in the programming mode. Only
then will you obtain the correct data on the fertilizer balance and the area it can cover.
! • When disconnecting plugs, you need to apply the dust caps to both plug and connection. This
eliminates malfunctioning of connections, if any, caused by dust and/or fertilizer.
! • Clean the machine thoroughly after each operation. Never aim a water jet at electronic boxes and plug
connections.
! • In case job activities are required for the CENTERMATIC weighing device (and connected machine),
the wires of the load cells must be disconnected.
6.7 Condensed instructions 37
Programming mode
By pressing the “Prog” button (B), you enter the CENTRONIC control system in the programming mode [refer
®
to “6.2 Programming of the CENTRONIC (Programming mode)”].
Read the screen: select the parameter required, enter the value you want or carry out the instruction given.
Press the RH arrow buttons (G) to select the parameter required or to adjust a value. Proceed to the next screen
by pressing the enter button (F). Scroll the screens until completion of programming.
Programming of the CENTRONIC control system is necessary if:
• the CENTRONIC control system is commissioned;
• other settings for working width, output rate, forward speed etc. are required;
• a fertilizer with a different setting factor is applied;
• a new output check or dynamic test needs to be carried out;
• the CENTRONIC control system needs to be geared to a different type of operation;
• day and/or total counters have to be reset at zero level;
• the forward speed sensor has to be calibrated anew (assembly of tyres with a different size, change of
tyre pressure or wheel slip);
• the CENTERMATIC weighing device needs taring (balance does not say 0 when spreader is empty);
• an error message in the display indicates that re-programming needs to be carried out.
Operation mode
All operations of the CENTRONIC control system take place in the operation mode (the light in the
programming button is not allowed to burn). By means of the start/stop button, the CENTRONIC control
system is switched from the stand-by position to the operation position (burning light in button) and vice
versa.
• Operation position:
- shutters open
- day/total counters running
• Stand-by position:
- shutters closed
- day/total counters stopped (with the exception of counters for distance covered)
- when tractor is immobile, the adjustment for the CENTRASIDE headland spreading device (if
attached) can be modified
Special functions in the operation mode:
- temporary increase/decrease during operation of the pre-programmed output/yield or shutter position [see
®
“6.3 Operation of the CENTRONIC (Operation mode)”].
- measuring of distance, to be used especially for laying out of working widths (first screen of data
sequences; see “6.3.1 Sequence AUTO-position”, “6.3.2 Sequence HAND-position” and “6.3.3 Sequence
ON BOARD COMPUTER-position”
38 7 ERROR MESSAGES
7 ERROR MESSAGES
The following error messages may be displayed.
O P E R ATION HAS Power supply is too low for proper functioning of the
STOPPED CENTRONIC putting a stop to fertilizer feeding. Check
BATTERY VOLTAGE TOO the battery and connections for bad contacts.
LOW !
ACTUATOR WAS NOT The CENTRONIC does not know the regulating details of
C A L I B R ATED the actuator. Regulate the actuator by means of the
C A R RY OUT INSTA L L ATION installation procedure (see supplement D).
PROCEDURE
®
ELECTRONIC BOX OF The version number of the CENTERLINER ‘s actuator
SPREADER IS NOT COR- control box is not compatible with your CENTRONIC ® .
R E C T. ATTENTION: COR- Replace the actuator control box with a box of the correct
RECT VERSION IS xxxx generation. Consult your dealer.
40 7 ERROR MESSAGES
*) As soon as the CENTRONIC control system is stopped and started anew, this
display disappears. The assumption is that the failure was remedied or that a new
setting factor was entered.
42 Supplement A
A TROUBLESHOOTING
Screen can not be read. • CENTRONIC control system not engaged. Press Power button.
Screen showing version • Incorrect brightness adjustment. Press “Prog” button (light in
number can be read, button should be burning) and adjust brightness by means of the
other screens can not. RH arrow buttons (also refer to “6.2 Programming of the
CENTRONIC ® )
Actuator stops before • Actuator not correctly calibrated. Check (in the position HAND)
®
shutters are closed or if the shutter position indicated by the CENTRONIC
keeps rattling when corresponds with the position of the calibration scale on the
shutters are closed. CENTERLINER spreader . If these positions are not matched,
calibrate the actuator by means of the installation procedure.
• Faulty actuator. Replace actuator.
• Incorrect adjustment of shutters. Check shutter adjustment
(see CENTERLINER spreader’s operator’s manual).
Incorrect output. • Output check not carried out properly. Repeat test.
- incorrect weight entered (bucket weight may have been included)
- second “obligatory” output check not carried out.
• CENTRONIC control system adjusted to headland spreading with
CENTRASIDE headland spreading device during full field operation,
or the other way around.
• Incorrect adjustment of shutters. Check shutter adjustment
(see CENTERLINER spreader’s operator’s manual).
• Incorrect adjustment of shutters. Check (in the position HAND) if the
shutter position indicated by the CENTRONIC controlsystem
corresponds with the position of the calibration scale on the
CENTERLINER spreader. If these positions are not matched,
calibrate the actuator by means of the installation procedure.
• Blockage of feed gates. Remove clods of fertilizer and/or foreign
matter from the gates. Use a sieve if the fertilizer contains clods
and/or other objects.
• Incorrect working width maintained or adjusted.
• Decline of calibration values of the CENTERMATIC weighing device.
Check (by using a known weight) if the CENTERMATIC® registers
the correct weight. If not, calibrate weighing element (contact
your dealer).
Spinner disc speed • Failing to process two different functions at the same time, being the
indicator is blinking actuator adjustment and spinner disc sensor information.
‘ If the actuator is adjusted to another position, the pulse
processing of the spinner disc sensor is interrupted. The latest
calculated speed remains visible on the screen, but blinks to
indicate that it is not an actual value. As soon as the actuator has
assumed its position, the actual speed will be displayed without
blinking.
44 Supplement B
®
B ASSEMBLY OF CENTRONIC COMPONENTS ON TRACTOR
B.1 Mounting the forward speed sensor and code disc
- Dismount one of the tractor’s rear wheels.
- Before mounting the code disc on the rim, check if it fits on the axle stub/flange of the rear axle assembly.
B-1 B-2
- Re-assemble the wheel to
the tractor. Leave the tractor
in its jacked-up position with a view to a check of the forward speed sensor, at a later stage of the assembly.
- Check if the swing of the code disc remains within 4 mm (radial direction) and 2 mm (axial direction) - see
fig. B-2.
5 mm
- Fit the sensor to the bracket.
The sensor’s position in
front of the code disc should
be roughly central in respect
of the slotted holes.
Adjust the distance between
the sensor and the code disc
at 5 mm (fig. B-4). B-3 B-4
- Guide the wire from the sensor to the tractor cab. Take care of moving and rotating parts and of parts which
may develop high temperatures. Tighten the wire by means of binder strips.
Supplement B 45
B.2 Socket
- Place the terminal block (fig. A-5) in the tractor cab.
A
Connection A is for the power supply. Connect the red wire to C
B
the plus terminal and the black wire to the minus terminal.
- Connect the terminal block behind the ignition lock of the
tractor. Connect the red wire (plus) to connection 15 or 54.
- Connect the black wire (minus) to the minus pole of the
battery.
Fit the fuse that was delivered with the control system in the
red wire (plus) between the ignition lock and the terminal
block to safeguard the electrical system against overload.
- Connect the forward speed sensor to connection (B, fig. B
B-5). The brown wire should be connected to the
A
connection and the blue wire to the (—) connection.
B-5
- Connect the wire of the control box to the socket (C, fig.
B-5).
! Make sure that the plug is clean (free from fertilizer) and
dry before its connection.
B-6
46 Supplement B
- Various possibilities are now displayed for the working method to be adjusted. In order to be able to test the
forward speed sensor, one of the following possibilities has to be selected:
HAND, AUTO (C), AUTO (CM) or BOARDCOM
- Press the enter button repeatedly until the display below appears:
DRIVE 20 m END
(Ignore this instruction)
AND PRESS END
S TART
0 IMPULSE ANEW
- Check the sensor by turning the tractor wheel to which the code disc was fitted.
Every pulse given by the sensor is accompanied by an acoustic signal. The display shows the number of
pulses.
The sensor has to give a pulse, each time a slotted hole of the code disc passes.
If this is not the case, then check the distance between the sensor and the code disc (approx. 5 mm, see fig.
B-4) and the swing of the code disc (see fig. B-2). Also, check if the sensor has a central position in respect of
the slotted holes. Make such adjustments as are necessary.
- After checking, press the enter button repeatedly, until the following display appears:
PROGRAMMING
FINISHED
ƒ
‚
•
C-1
Observation:
The 12V power supply • is switched on and off simultaneously with engaging and disengaging of the
CENTRONIC control system.
48 Supplement D
NO
After the selection “NO” the procedure is
ended.
YES
S E T T I N G PROCEDURE After approx. 3 seconds the CENTRONIC
FINISHED control system automatically assumes the
programming mode.
AND EXTEND
STROKE OF ACTUATOR The spindle now retracts and extends completely.
IS NOW BEING
Then the next announcement is displayed.
MEASURED
Calciumammoniumnitrate