Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

NOTES

GENERAL NOTES

PERCOLATION 1- SEPTIC TANK TO BE OF THE APPROPRIATE SIZES AS PER TABLE, BUILT IN


No. OF USERS L(mm) B(mm) D(mm) CAPACITY(LTRS) TRENCHE LENGTHS BRICK/BLOCK WORK IN 1:3 CEMENT MORTAR WITH 125mm th 1.This drawing is protected under the copyright Act,
CONC. FOUNDATION MIX 1:3:6 WHERE DEPTH EXCEEDS 1500mm ,RENDE and cannot be used or reproduced in part or in whole
INTERNALLY TO SIDES,BOTTOM WITH 1:3 CEMENT MORTAR 12mm TH WITH without outthors consent.
F2 7.5m STEEL TROWEL FINISH.
6 1800 675 900 1112.5
2- IN-LET & OUTLET PIPES TO BE 100mm DIA. CASTIRON PIPES TO BS 437 & 2. Read only figured dimensions.
10 2250 675 900 1417.5 12.2m SECURED TO WALLS BY GALVANISED IRON BRACKETS TARRED & SANDED &
E D
G BUILT
F1
15 2500 675 900 1561.5 14.4m INTO BRICK WORK. 3. All construction work is to comply with the latest
standard code of practice, LOCAL AUTHORITY BY-
20 3- 100mm DIA.CAST IRON DRAIN PIPE FROM SEPTIC TANK TO EFFLUENT
Access Road 2800 675 900 1800.0 18.3m LAW, & FIRE REGULATIONS.
CHAMBER TO BE LAID TO MAIN FALL 1:40.
PLOT
25 3300 675 900 2083.5 30.5m 4- PROVIDE 100mm DIA. HALF ROUND SALT GLAZED -WARE Y-JUCTION
CHANNEL TO EFFLUENT CHAMBER PROPERLY BENCHED AS TO PREVIOUSLY
4. P.V. denotes permanent ventilation and must be

PLOT
30 2500 900 1050 2358.0 36.6m DESCRIBED WITH C.I CHANNEL STOP SECURED WITH 12mm LINK GALVANISED provided above all doors and windows where indicated
C2 J
B CHAIN ONE END FIXED 150mm BELOW COVER SLAB. or shown.
Residue
35 2550 900 1050 2502.0 42.6m
5- PERCOLATION TRENCHES TO BE AS SHOWN & LENGTH TO BE AS
Residue PLOT PERTABLE ,DEPTH OF TRENCH TO BE 450mm DEEPER THAN INVERT OF 5. All walls less than 200mm thick to be reinforced
40 3000 900 1050 2847.5 48m 10Omm
192 with hoop iron at every alternate course.
DIA. AGRICULTURAL PIPES LAID TO 1:100 MAIN FALL WITH OPEN JOINT ON
From Kira 45 3300 900 1050 3240.0 54.8m 150mm DOWN TO 30mm STONE CAREFULLY SORROUNDED PIPES TO A
HEIGHT OF 300mm ABOVE PIPE INVERT LEVEL WITH SIMILAR STONE 6. Water meter to be 300mm above G.L.
50 3600 900 1050 3685.5 60.0m ,COVERED WITH ROOFING FELT AS DIRECTED & FILLING IN REMINDER OF
TRENCHE TO GROUND LEVEL WITH SELECTED FILL MATERIAL.
7. D.P.C. denotes one layer of bituminous felt to be
60 3150 1200 1200 4419.0 66.0m
SITE LOCATION MAP From Mukono & 6- ALL MANHOLES, R.C SLABS TO PROJECT ATLEAST 50mm ABOVE GROUND provided under all walls 150mm above G.L.
Akright Estate LEVEL TO CATER FOR INCREASE OF STORM WATER.
70 3750 1200 1200 5265.0 73.0m
8. All R.C. works to structural engineer`s details.
80 4250 1200 1200 6895.0 79.2m
9. Provide 1 row of 600 x 600 50mm precast concrete
90 4720 1200 1200 6525.0 85.2m
paving slabs arounnd the building unless otherwise
100 5300 1200 1200 7416.0 91.0m shown.

10. Contractors must verify all dimensions and levels


on site before commencing work. Any discrepancies
Selected Filling in 6 layers wll must be reported to the architect before work is put in
rammed and consolidated
900 hand.
GROUND
LEVEL 600 x 450 mm precast 100mm dia . Half Round Y
100mm dia .Agricultural pipe laid
open joint 11. All levels shown are finished levels unless
conc. cover
Junction Channel to soak pit otherwise stated.
ROOFING
12. All surface beds to be cast on well compacted and
TO BE DETARMINED ON

Cast Iron
FELT
Selected stone Channel Stop
Invert 100mm dia Salt glazed
100mm dia Cast Iron Inlet
pipes
well consolidated filling.
level SELECTED stone pipe
450x450mm
MH

STONE B
SITE

100mm dia .Agricultural 150 DOWN TO 13. Depth of foundation trenches to be minimum
100mm dia . Half Round 100mm dia Cast Iron
pipe laid open joint 20mm L 100mm dia Cast Iron
100mm dia. 600mm below reduced ground level.
Channel pipe drain to soak pit
Outlet pipe
( mean fall 1 in 100) INLET CHAMBER

inlet / outlet INTERNAL PLAN EFFLUENT DISTRIBUTION


CHAMBER
600 D cast iron pipe 100mm th R.C cover with
14. All pipes and services to be minimum 450mm
NGITUDINAL SECTION LONGITUDINAL SECTION 16mm dia. bars at 150mm
picth either way SOAKPIT SYSTEM
below reduced ground level.
B
GH PERCOLATION TRENCH CROSS SECTION THROUGH PERCOLATION TRENCH PERCOLATION TRENCH SYSTEM
THROUGH DRAIN PIPE
TRENCH
SECTION Y-Y
LONGITUDINAL SECTION
100mm th.slab(mix.1:2:4)reinforced with Y12 Bars
at 150mm c/c both way 600 x 450 mm precast
THROUGH PERCOLATION TRENCH conc. cover
GROUND LEVEL

DATE DESCRIPTION

300 min
4230 100mm dia half round REVISIONS
REVISION
3000 3000 Benching
channel
4000 R IN WORKING LEVEL OUT

125mm thick concrete base (mix. gl. support bracket built ARCHITECT:
1:3:6). Depth to invert level not into 230mm thick block
more than 1500mm
D
wall Arch Kwesegamu Samuel
L

min
450
DESIGN & ADVISORY CONSULT
530

25mm th. cement screed finished


GATE CONCRETE CONCRETE Concrete to foundation (mix 1:3:6)
to be at thickness specified
smooth with steel float. P.O BOX 5065
COPING COPING
KAMPALA
900

R
230 LONGITUDINAL SECTION THROUGH SEPTIC TANK
CLIENT:
Eng.JUSTIN OMODING ANGIRO AND
SPIKES MRS.CHRISTINE MARGARET
1200

Y
890 890 890 ANGIRO
840 840 840

600x450mm PROJECT:
Prer-cast Conc. 600x450mm Prer-cast Conc. cover
GRILL GRILL with12mm dia.mild steel to form
900 cover
lifting handles PROPOSED GIRLS HOSTEL TO BE BUILT
450x450mm 12mm Rendering ON PLOT........, ORAGIN ROAD NGORA
FOUNDATION DEPTH TO BE Prer-cast Conc. finished TOWN COUNCIL
230

DETERMINED FROM SITE AND


cover Y
with steel float
STEEL PLATE STEEL PLATE 1200 100mm th R.C Slab
690 NOT LESS THAN 760mm. Title
WELL PAINTED BLOCK WORK
PLAN OVER COVER

750
DESINED BY: N.O
WALL BOUNDARY SECTION
Date
SECTIONAL DETAIL DRAWN BY: A.F SEPT.2014
SHOWING BENCHING Job no. Scale
1:50,1:75
Sheet no. Owner`s signature
02

You might also like