Product Environmental Profile: FBM214/216 Termination Assembly Termination Assemblies

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Product Environmental Profile

FBM214/216 Termination Assembly

Termination Assemblies

ENVPEP2106003_V1 # Internal 06/2021


General information
Representative product FBM214/216 Termination Assembly - P0926EA
Description of the product Termination assembly is used by I/O module's to transfer signals to or from the field.
Termination Assemblies for locally or remotely connecting field wiring to the FBM's.
Description of the range The environmental impacts of this referenced product are representative of the impacts of the other
products of the range which are developed with a similar technology.

Termination assembly is passive extender, used to extend signals from the field to I/O module by
Functional unit performing signal conduction during 20 years of life time with 0 W power consumption and 100%
use rate.

Constituent materials
Reference product mass 345 g including the product, its packaging and additional elements and accessories

PUR Polyurethane - 1.4% UP Polyester - 0.7%


PE Polyethylene - 2%
Stainless steel - 7.8%
PVC Polychlorure de vinyle -
2.9%
Cardboard - 24.6%
PC Polycarbonate - 15.1%

PA Polyamide - 20.9%

Electronic components -
24.5%

Plastics 43.0%
Metals 7.8%
Others 49.1%

Substance assessment

This product contains: Lead >0.1%. These percentages are relative to the total mass of the product.

Details of ROHS and REACH substances information are available on the Schneider-Electric Green Premium website
http://www2.schneider-electric.com/sites/corporate/en/products-services/green-premium/green-premium.page

ENVPEP2106003_V1 # Internal 06/2021


Additional environmental information
The FBM214/216 Termination Assembly presents the following relevant environmental aspects
Manufacturing Manufactured at a Schneider Electric production site ISO14001 certified
Weight and volume of the packaging optimized, based on the European Union's packaging directive
Distribution
Packaging weight is 97 g, consisting of Cardboard (87.73%), Polyurethane Foam (5.12%), Polyethylene (7.17%)

Installation FBM216 Termination Assembly does not require any installation operations.
Use The product does not require special maintenance operations.

End of life optimized to decrease the amount of waste and allow recovery of the product components and materials

This product contains Electronic boards (84.5 g) that should be separated from the stream of waste so as to optimize
end-of-life treatment.

End of life The location of these components and other recommendations are given in the End of Life Instruction document which
is available on the Schneider-Electric Green Premium website
http://www2.schneider-electric.com/sites/corporate/en/products-services/green-premium/green-premium.page
Based on “ECO’DEEE recyclability and recoverability calculation method”
Recyclability potential: 15% (version V1, 20 Sep. 2008 presented to the French Agency for Environment
and Energy Management: ADEME).

Environmental impacts
Reference life time 20 years
Product category Other equipments - Passive product - continuous operation
Installation elements No special components needed
Use scenario The product is in use 100% of the time with a power consumption of 0W for 20 years
Geographical
USA
representativeness
Technological
Termination assembly is used by I/O module's to transfer signals to or from the field.
representativeness
Manufacturing Installation Use End of life

Energy model used Electricity mix; AC; Electricity mix; AC; Electricity mix; AC;
Energy model used: Mexico consumption mix, at consumption mix, at consumption mix, at
consumer; 120V; US consumer; 120V; US consumer; 120V; US

Compulsory indicators FBM214/216 Termination Assembly - P0926EA


Impact indicators Unit Total Manufacturing Distribution Installation Use End of Life
Contribution to mineral resources depletion kg Sb eq 1.91E-04 1.91E-04 0* 0* 0* 0*
Contribution to the soil and water acidification kg SO2 eq 6.81E-03 6.47E-03 2.03E-04 2.38E-05 0* 1.14E-04
Contribution to water eutrophication kg PO43- eq 1.97E-03 1.86E-03 4.68E-05 9.28E-06 0* 5.34E-05
Contribution to global warming kg CO2 eq 4.68E+00 4.47E+00 4.45E-02 5.80E-03 0* 1.63E-01
kg CFC11
Contribution to ozone layer depletion 3.51E-07 3.46E-07 9.02E-11 3.64E-11 0* 5.55E-09
eq
Contribution to photochemical oxidation kg C2H4 eq 9.84E-04 9.58E-04 1.45E-05 1.79E-06 0* 9.72E-06
Resources use Unit Total Manufacturing Distribution Installation Use End of Life
Net use of freshwater m3 2.23E-02 2.22E-02 3.98E-06 0* 0* 8.47E-05
Total Primary Energy MJ 6.61E+01 6.49E+01 6.29E-01 7.37E-02 0* 4.91E-01

ENVPEP2106003_V1 # Internal 06/2021


100%

90%

80%

70%

60%

50%

40%

30%

20%

10%

0%
Contribution to Contribution to Contribution to Contribution to Contribution to Contribution to Net use of Total Primary
mineral the soil and water water global warming ozone layer photochemical freshwater Energy
resources acidification eutrophication depletion oxidation
depletion

Manufacturing Distribution Installation Use End of life

Optional indicators FBM214/216 Termination Assembly - P0926EA


Impact indicators Unit Total Manufacturing Distribution Installation Use End of Life
Contribution to fossil resources depletion MJ 4.09E+01 3.98E+01 6.25E-01 7.20E-02 0* 4.01E-01
Contribution to air pollution m³ 5.28E+02 5.22E+02 1.89E+00 3.12E-01 0* 3.58E+00
Contribution to water pollution m³ 7.55E+02 7.40E+02 7.32E+00 8.42E-01 0* 7.24E+00
Resources use Unit Total Manufacturing Distribution Installation Use End of Life
Use of secondary material kg 7.97E-02 7.97E-02 0* 0* 0* 0*
Total use of renewable primary energy resources MJ 6.42E-01 6.41E-01 8.39E-04 3.78E-04 0* 4.69E-04

Total use of non-renewable primary energy resources MJ 6.54E+01 6.43E+01 6.29E-01 7.33E-02 0* 4.90E-01

Use of renewable primary energy excluding renewable


MJ 3.89E-01 3.87E-01 8.39E-04 3.78E-04 0* 4.69E-04
primary energy used as raw material
Use of renewable primary energy resources used as
MJ 2.53E-01 2.53E-01 0* 0* 0* 0*
raw material

Use of non renewable primary energy excluding non


MJ 5.98E+01 5.86E+01 6.29E-01 7.33E-02 0* 4.90E-01
renewable primary energy used as raw material

Use of non renewable primary energy resources used


MJ 5.61E+00 5.61E+00 0* 0* 0* 0*
as raw material
Use of non renewable secondary fuels MJ 0.00E+00 0* 0* 0* 0* 0*
Use of renewable secondary fuels MJ 0.00E+00 0* 0* 0* 0* 0*
Waste categories Unit Total Manufacturing Distribution Installation Use End of Life
Hazardous waste disposed kg 2.81E+00 2.26E+00 0* 0* 0* 5.44E-01
Non hazardous waste disposed kg 1.24E+00 1.23E+00 1.58E-03 1.02E-02 0* 1.35E-03
Radioactive waste disposed kg 4.61E-04 4.56E-04 1.13E-06 4.54E-07 0* 3.10E-06
Other environmental information Unit Total Manufacturing Distribution Installation Use End of Life
Materials for recycling kg 1.51E-01 2.52E-02 0* 8.80E-02 0* 3.82E-02
Components for reuse kg 0.00E+00 0* 0* 0* 0* 0*
Materials for energy recovery kg 4.32E-02 0* 0* 0* 0* 4.32E-02
Exported Energy MJ 2.69E-04 2.53E-05 0* 2.43E-04 0* 0*
* represents less than 0.01% of the total life cycle of the reference flow
Life cycle assessment performed with EIME version EIME v5.9.1, database version 2016-11 in compliance with ISO14044.

ENVPEP2106003_V1 # Internal 06/2021


The manufacturing phase is the life cycle phase which has the greatest impact on the majority of environmental indicators (based on
compulsory indicators).
Please note that the values given above are only valid within the context specified and cannot be used directly to draw up the environmental
assessment of an installation.

Registration number ENVPEP2106003_V1 Drafting rules PCR-ed3-EN-2015 04 02

Date of issue 06/2021


Information and reference
Validity period 5 years www.pep-ecopassport.org
documents
Independent verification of the declaration and data
Internal X External
The elements of the present PEP cannot be compared with elements from another program.
Document in compliance with ISO 14021:2016 « Environmental labels and declarations - Self-declared environmental claims (Type II
environmental labelling) »

Schneider Electric Industries SAS


Country Customer Care Center:
http://www2.schneider-electric.com/sites/corporate/en/support/operations/local-operations/local-operations.page
+001 508 549 3992
38 Neponset Avenue
Foxboro
MA 02035

USA

www.schneider-electric.com Published by Schneider Electric


ENVPEP2106003_V1 © 2021 - Schneider Electric – All rights reserved 06/2021

# Internal

You might also like