Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Elevation C 20'-4 3/4"

16'-0" 20'-4 3/4" C Of Post Above


L
9'-4" 5'-4" 1'-4"
244GW5040 16'-4 1/2" 4'-1/4"
3'-1 1/4" 5'-1" 8'-2 1/4"

1'-0"
8'-0" 8'-0"
4x4 Post

Solid Blocking Under Post


4'-1 1/2"

Bunk Beds
4'-4"

By Owner

S262-3068 R

6'-2 1/4"

6'-2 1/4"

6'-2 1/4"
6'-2 1/4"
3'-6"
2'-11"

10

PT 2x6 Deck Joists 16" O.C.


(2)-2x6 Box

Elevation B
Elevation D

V-Match Door

Covered Porch
4x4 Post
Built On Site

2'-1"
244GW3030

12'-4 1/2"

12'-4 1/2"
12'-4 1/2"
12'-0"

2468
3'-4"

3'-9"

1/2 Bath PT 6x6 Support Post PT 2x8 Floor Joists 16" o.c.

Porch Supports Need To Be 1 3/8"


Shorter Than House Supports

244GW3030
10
(2)-2x8 Box

3'-4"

Solid Blocking Under Post


(2)-2x8 Box

6'-2 1/4"

6'-2 1/4"

6'-2 1/4"
6'-2 1/4"
6'-0"
4'-1 1/2"
4'-4"

Bunk Beds
By Owner

2'-1"
4x4 Post
8'-0" 8'-0"

244GW5040 8'-2 1/4" 8'-2 1/4" 4'-1/4" 3'-1 1/4" 5'-1" 8'-2 1/4" 4'-1/4"
9'-4" 5'-4" 1'-4" 3'-11"
C Of Post Above
L
16'-4 1/2"
Elevation A
Dashed Line Represents Outside Of Floor Frame
All Materials For Exterior Stairs
And Stair Railings By Others
PT 6x6x8' Posts Supplied. Posts Should Be Set On
A Concrete Footing At A Point Below The Frost Line 4x4 Post Above Sheathing

Window Schedule Color Sandtone Floor Frame Notes


Quantity ID R.O. Porch Supports Need To Be 1 3/8" - Support Posts By Others
Higher Than House Supports
2 244GW3030 3'-0" X 3'-0"
- (2)-PT 2x8 Box For Floor System Floor Sheathing
2 244GW5040 5'-0" X 4'-0"
- PT 2x8 Floor Joists 16" O.C.
Foundation Plan - Solid Blocking Under All Posts
Door Schedule
SCALE: 3/8" = 1'-0" - 5/8" T&G Advantech Subfloor
Qty Doors
- 1" V-Match Finished Floor
1 S262-3068 R
- PT 2x6 Double Box For Deck

- PT 2x6 Deck Joists 16" O.C. 2x8 Solid Blocking


1. Floor Plan - PT 5/4" Porch Decking
SCALE: 3/8" = 1'-0"
- Joist Hangers (As Needed) By Others
2x8 Floor Joists 16" o.c.

Notice: To Comply With Local Codes These


Construction Requirements Must Be Met.
Solid Blocking Detail
NOT TO SCALE
Roof Insulation__________________Min.
Notice: Building Design To Meet Floor Insulation__________________Min.
The Following Load Conditions: (Not Required If Foundation Walls Are Insulated)
1st Floor: 40# /Ft. Live Load Foundation Insulation______________Min. Floor Frame
2nd Floor: 30# /Ft. Live Load (Not Required If 1st Floor Is Insulated.) SCALE: 3/8" = 1'-0"
Roof System 70# /Ft. Ground Snow Load Glazing: High Performance
Wind Load: 70 MPH, Exposure "B" Storms________________________________

Building Is Designed In Accordance


Above Weight Loads Are Based On Normal Materials With ICC-400 Log Standard 2007
Supplied By Coventry Log Homes. Any Variance Of
"Size Or Spacing" May Affect Weight Loads. Logs Are "Wall Grade" Eastern White Pine, Graded
In Accordance With "Log Homes Council" Standards

Average Moisture Content Of Logs Is 19% Or Less


Per LHC Grading Manual

This Cabin Is A Recreational Series/No-Change Design. Any Changes Must Be


Made On The Job. Consult Your Local Codes Before Making Any Changes. Coventry Log Homes
108 South Court Street Customer
Important Note: Copyright 2011 All Rights Reserved. These Plans Are Designed And Intended For The Woodsville N.H. 03785
Customer Site Location: Unknown
The Builder Must Review The Price Quote List To Determine the List Of Materials Being Sole Use Of Constructing A Log Home Package Supplied By Coventry Log Homes, Inc.
Purchased From Coventry Log Homes. Any Other Materials Required To Build The Log www.coventryloghomes.com Design PQ #
Home But Not Listed On The Price Quote Are To Be Supplied By The Builder Or Customer.
Phone 1-(603)-747-8177
Standard Getaway House: 13 Log Rows 9/12 Roof Pitch 2011
Refer To Your Construction Manual For Specific Details. Coventry Log Homes Owner Should Check All Dimensions. Do Not Build Scale 1/4" = 1'
Toll Free 1-(800)-308-7505 Date
Recommends Owner & Builder Read And Review Before Starting Construction. From These Plans. Use Final Plans Only
Fax 1-(603)-747-3340 February 28, 2011 Unless Noted Otherwise Page 1 of 3
2x4 Strapping 2x4 Strapping 2x4 Strapping
1 3/4" x 11 7/8" LVL Ridge 1 3/4" x 11 7/8" LVL Ridge 1 3/4" x 11 7/8" LVL Ridge

Steel Roofing Steel Roofing Steel Roofing


A B 2" Rigid Insulation 2" Rigid Insulation 2" Rigid Insulation

2 2 12 12
Log Blocking Between Rafters 4x 4x
2x Ripped To Thickness Of Insulation
4x
1" V-Match OJ 8x 9 1" V-Match OJ 8x 9 OJ 8x
sC 10 sC 10
sC 10

4x4x5' Post COJ


r 'R r 'R 1" V-Match
f t e aft f t e aft ter 'R
Ra er 15# Felt Paper Over V-Match Ra er 15# Felt Paper Over V-Match af aft
0' sC 0' sC 'R er
sC
8x1 OJ 8x1 OJ x10 OJ
4x 4x 8
2x Ripped To Thickness 4x 4x
4x J
4' CO 15# Felt Paper Over V-Match
Of Insulation W g
eb bin
1x8 Facia (Typ.) bi
ng eb
Log Blocking Between Rafters Log Blocking Between Rafters 'W
2x4 Roof Box 4x8 Rafters 32" O.C. CO
4x
4
V-Match 2x4 Roof Box 2x4 Roof Box J 4x 2x4 Roof Box

2x4 Header Be sure To Put Lag


Porch Header
Into "N" Log Row
1x8 Facia 1x8 Facia 1x8 Facia

Blocking For
4x8 Fly Rafter 4x8 Fly Rafter V-Match
4x4x10' Post COJ 4x4x10' Post COJ
V-Match

4x4x8' Post COJ

4x4x8' Post COJ


4x4x8' Post COJ
Bath

1x8 Rake (Typ.)

2x4 Roof Box Gable Wall


3/8" x 5" Lag Bolts
Every Other Log Row
All Posts

V-Match " V-Match PT 5/4" Porch Decking

1 3/4" x 11 7/8" LVL Ridge


5/8" Advantech Subfloor 5/8" Advantech Subfloor
(2)-PT 2x8 Box (2)-PT 2x8 Box PT 2x8 Floor Joists 16" O.C. PT 2x6 Double Box

Gable Wall Collar Tie Below Collar Tie Below 1x8 Skirtboard 1x8 Skirtboard
Solid Blocking Solid Blocking
PT (2)-2x8 Floor Joists 16" O.C. 2x4 Bathroom Frame

Note: COJ Indicates That Pieces Are Sent Longer Than Necessary. Note: COJ Indicates That Pieces Are Sent Longer Than Necessary. Note: COJ Indicates That Pieces Are Sent Longer Than Necessary.
2x Ripped To Thickness
Exact Length Needs To Be Determined On Site Exact Length Needs To Be Determined On Site Exact Length Needs To Be Determined On Site
4x8 Fly Rafter Of Insulation
Note: Actual Pitch Of Roof Determined By Assembled Gable. Note: Actual Pitch Of Roof Determined By Assembled Gable. Note: Actual Pitch Of Roof Determined By Assembled Gable.
Actual Pitch May Vary Slightly From That Noted On Plan Actual Pitch May Vary Slightly From That Noted On Plan Actual Pitch May Vary Slightly From That Noted On Plan

4x8 Fly Rafter

2x4 Strapping
Section A2 Section B2 Section C2
SCALE: 3/8" = 1'-0" SCALE: 3/8" = 1'-0" SCALE: 3/8" = 1'-0"

11 1/2"
2'-4 1/2" 2'-8" 2'-8" 2'-8" 2'-8" 2'-8" 2'-8" 2'-8"

2x4 Roof Box

Olylogs (Typ.)
Foam Insulation
At Top Of Radius
C
Roof Frame Notes
2
- 4x8 Rafters 32" O.C.
- 1" V-Match Ceiling 4x8 Blocking Between Rafters
- 15# Felt Paper Over V-Match Bead Of Caulking Outside Of Foam

- 2x4 Box For Roof Foam Insulation


- 2" Rigid Insulation
- 2x4 Strapping
- 1x8" Facia House 4x8 Log Blocking Between Rafters
- Porch Ceiling T&G Pine
Notch Tongue Of Log for Rafter

Roof Frame
SCALE: 3/8" = 1'-0"

"
2x4 Strapping /4 Foam Insulation
43 Peak Of 1x8 Rake Boards
Caulking
1 3/4" x 11 7/8" LVL Ridge
2" Rigid Insulation
1/2
" "A" Row Log Wall
12 10
1'-
Steel Roofing
Olylog
2" Rigid Insulation 9 Plywood Starter Strip Nailed
4x 1/2
"

COJ 8x
10 1'-
10
Into Groove Of "A" Row 1/2"x7" Lag Bolts
(By Others) Every
s Caulking Sill Seal
r 'R Other Row
afte af 12
'R te /2" Detail 10
rs 01
10
9 1
1" V-Match x CO 2x4 Strapping 1'-
8 Caulking Under Starter Strip
4x J Side View
15# Felt Paper Over V-Match
4x8x10' Collar Ties COJ 1/
4" 1x8 Skirtboard Studs 16" O.C.
2'- (2)-PT 2x8 Box
2x4 Strapping Log Wall
Actual Pitch Of Roof Determined By Assembled Gable.
1/2" x 7" Lag "
1/2 Actual Pitch May Vary Slightly From That Noted On Plan
1/2" x 5" Lag 2
2x4 Roof Box 1'- Log Wall
W/ Washers
(By Others) Dimensions Given Are For Reference Only.
Actual Dimensions May Vary On Site.
Top Of Radius Of Log
Log Blocking Between Rafters Should Line Up With Top
Of Rafter Place Top 2x4 Near Ridge To PT 6x6 Post Bottom Plate
Accommodate Fastening Of Ridge Cap
1x8 Facia
Rip Scrap Pine to Hold Insulation
Until Strapping Is In Place
3-2x4 Studs At
Intersection Of
Top View Log Wall

Collar Tie Detail Strapping Detail Skirtboard/"A" Row Detail Detail 10


SCALE: 1/2" = 1'-0" SCALE: 1/2" = 1'-0" SCALE: 1 1/2"= 1'-0" NOT TO SCALE

This Cabin Is A Recreational Series/No-Change Design. Any Changes Must Be


Made On The Job. Consult Your Local Codes Before Making Any Changes. Coventry Log Homes
108 South Court Street Customer
Important Note: Copyright 2011 All Rights Reserved. These Plans Are Designed And Intended For The Woodsville N.H. 03785
Customer Site Location: Unknown
The Builder Must Review The Price Quote List To Determine the List Of Materials Being Sole Use Of Constructing A Log Home Package Supplied By Coventry Log Homes, Inc.
Purchased From Coventry Log Homes. Any Other Materials Required To Build The Log www.coventryloghomes.com Design PQ #
Home But Not Listed On The Price Quote Are To Be Supplied By The Builder Or Customer.
Phone 1-(603)-747-8177
Standard Getaway House: 13 Log Rows 9/12 Roof Pitch 2011
Refer To Your Construction Manual For Specific Details. Coventry Log Homes Owner Should Check All Dimensions. Do Not Build Scale 1/4" = 1'
Toll Free 1-(800)-308-7505 Date
Recommends Owner & Builder Read And Review Before Starting Construction. From These Plans. Use Final Plans Only
Fax 1-(603)-747-3340 February 28, 2011 Unless Noted Otherwise Page 2 of 3
Note: Actual Pitch Of Roof Determined By Assembled Gable.
Actual Pitch May Vary Slightly From That Noted On Plan

12

244GW3030
244GW5040

S-262-3068 R

ELEVATION A
SCALE: 3/8" = 1'-0" ELEVATION B
SCALE: 3/8" = 1'-0"

Notes: Note: Actual Pitch Of Roof Determined By Assembled Gable.


Actual Pitch May Vary Slightly From That Noted On Plan

Fastener Spacing 24" o.c.

Logs Shorter Than 24" Require


A Minimum Of 2 Fasteners 12

Center Gable On Wall 9

244GW3030

244GW5040

ELEVATION C ELEVATION D
SCALE: 3/8" = 1'-0" SCALE: 3/8" = 1'-0"

This Cabin Is A Recreational Series/No-Change Design. Any Changes Must Be


Made On The Job. Consult Your Local Codes Before Making Any Changes. Coventry Log Homes
108 South Court Street Customer
Important Note: Copyright 2011 All Rights Reserved. These Plans Are Designed And Intended For The Woodsville N.H. 03785
Customer Site Location: Unknown
The Builder Must Review The Price Quote List To Determine the List Of Materials Being Sole Use Of Constructing A Log Home Package Supplied By Coventry Log Homes, Inc.
Purchased From Coventry Log Homes. Any Other Materials Required To Build The Log www.coventryloghomes.com Design PQ #
Home But Not Listed On The Price Quote Are To Be Supplied By The Builder Or Customer.
Phone 1-(603)-747-8177
Standard Getaway House: 13 Log Rows 9/12 Roof Pitch 2011
Refer To Your Construction Manual For Specific Details. Coventry Log Homes Owner Should Check All Dimensions. Do Not Build Scale 1/4" = 1'
Toll Free 1-(800)-308-7505 Date
Recommends Owner & Builder Read And Review Before Starting Construction. From These Plans. Use Final Plans Only
Fax 1-(603)-747-3340 February 28, 2011 Unless Noted Otherwise Page 3 of 3

You might also like