Construction up to 4 Storeys:
Lightweight Cladding.
Intended Use
of this Document
This document provides example key
assembly interface details showing the These example details are intended to provide architects,
use of ROCKWOOLTM products within builders, and contractors with general guidance on the
best practice approach to maintain:
a split-insulated wall assembly for
commercial buildings up to 4 stories. • Air barrier continuity,
The example details could be modified for other building • Water resistant barrier (moisture barrier) continuity,
types or applications. The intended use has been limited
• Thermal continuity and minimizing thermal bridges,
to 4 stories for the sole purpose of creating boundaries
around the detail development. The example details • Cladding attachment and detailing, and
are designed to be generally applicable across North
America; however, specific end use applications vary • Adequate drainage and ventilation of the wall cavity.
widely as to design, materials, and environments.
Therefore, what is appropriate in any specific end It is important to note these details show one method
use application is a determination that must be made of constructing a split-insulated, exterior air barrier wall
independently by the experienced Project Architect assembly; however, subtle changes at interface locations
and/or Engineer in their own professional judgment. could be made to achieve the same intent. Review the
ROCKWOOLTM fully disclaims any liability for any of building code requirements for your jurisdiction to ensure
the content contained herein whether such liability be that all wall assembly detailing is in general conformance,
premised on a theory of contract, tort, or otherwise. or contact ROCKWOOLTM Building Science Support for
support on your project.
ROCKWOOL
1
Free-draining
backfill
Concrete slab
on grade
Perforated
drain pipe with
filter fabric
COMMERCIAL STEEL FRAME CONSTRUCTION UP TO .\WEB RGB ROCKWOOL™ logo - Primary Colour.png
June 11 2020 4:22 PM
TM TM
* For thermal performance of ROCKWOOL products, please refer to ROCKWOOL technical data sheets
** For climate zone specific considerations for thermal, air and vapor control layer properties and requirements, please contact ROCKWOOLTM Building Science for support.
Composite metal panel
cladding system over
Vapor control layer** vertical metal hat
tracks fastened to steel
studs
Gypsum board c/w 2
212" (64mm) ROCKWOOL
layers latex paint COMFORTBOARDTM
80/110 insulation
Fill cavity with 6"
(150mm) ROCKWOOL
Exterior gypsum
COMFORTBATT®
board sheathing
[312" (89mm)
ROCKWOOL Air space
COMFORTBATT® also
available] Vapor permeable
membrane (AB/WRB)**
Self adhesive
6" steel stud framed
through-wall flashing
wall
membrane (AB/WRB)
Pre-finished metal
Concrete slab flashing over top of cover
on grade board
Foundation
dampproofing/
waterproofing (WRB)
Vapor control layer,
all joints taped
Concrete slab on grade,
212" (64mm) ROCKWOOL sloped away from building
COMFORTBOARDTM
80/110 insulation
COMMERCIAL STEEL FRAME CONSTRUCTION UP TO .\WEB RGB ROCKWOOL™ logo - Primary Colour.png
June 11 2020 4:22 PM
* For thermal performance of ROCKWOOLTM products, please refer to ROCKWOOLTM technical data sheets
** For climate zone specific considerations for thermal, air and vapor control layer properties and requirements, please contact ROCKWOOLTM Building Science for support.
Vapor control layer**
Composite metal panel
cladding system over
vertical metal hat
Gypsum board c/w 2 tracks fastened to steel
layers latex paint studs
Air space
Fill cavity with 6" (150mm)
ROCKWOOL 212" (64mm) ROCKWOOL
COMFORTBATT® COMFORTBOARDTM
[312" (89mm) ROCKWOOL 80/110 insulation
COMFORTBATT® also
available]
Exterior gypsum
board sheathing
6" steel stud framed wall
Vapor permeable
membrane (AB/WRB)**
Pre-finished metal
flashing over top of cover
board
Alternate insulation
location, 212" (64mm) ROCKWOOL
ROCKWOOL COMFORTBOARDTM
COMFORTBATT® 80/110 insulation
to fill stud cavity
Foundation dampproofing/
Service cavity waterproofing (WRB)
(2x3)
COMMERCIAL STEEL FRAME CONSTRUCTION UP TO .\WEB RGB ROCKWOOL™ logo - Primary Colour.png
June 11 2020 4:22 PM
* For thermal performance of ROCKWOOLTM products, please refer to ROCKWOOLTM technical data sheets
** For climate zone specific considerations for thermal, air and vapor control layer properties and requirements, please contact ROCKWOOLTM Building Science for support.
Vapor control layer**
Self adhesive
through-wall flashing
membrane w/ sealant at
top edge (WRB)
Acoustic caulking
(Optional)
COMMERCIAL STEEL FRAME CONSTRUCTION UP TO .\WEB RGB ROCKWOOL™ logo - Primary Colour.png
June 11 2020 4:22 PM
* For thermal performance of ROCKWOOLTM products, please refer to ROCKWOOLTM technical data sheets
** For climate zone specific considerations for thermal, air and vapor control layer properties and requirements, please contact ROCKWOOLTM Building Science for support.
Air space
212" (64mm) ROCKWOOL
Vapor control layer** COMFORTBOARDTM
80/110 insulation
Pre-finished metal
flashing
Vapor permeable
Gypsum board c/w 2 membrane (AB/WRB)**
layers latex paint
Heavy cladding
(brick, stone, etc.)
COMMERCIAL STEEL FRAME CONSTRUCTION UP TO .\WEB RGB ROCKWOOL™ logo - Primary Colour.png
June 11 2020 4:22 PM
* For thermal performance of ROCKWOOLTM products, please refer to ROCKWOOLTM technical data sheets
** For climate zone specific considerations for thermal, air and vapor control layer properties and requirements, please contact ROCKWOOLTM Building Science for support.
Vapor control layer** Air space
Fill cavity with 6" (150mm)
Gypsum board c/w 2 ROCKWOOL
layers latex paint COMFORTBATT®
[312" (89mm) ROCKWOOL
COMFORTBATT® also
available]
6" steel stud framed wall
Acoustic caulking
212" (64mm) ROCKWOOL
COMFORTBOARDTM
80/110 insulation
Self adhesive
through-wall flashing
membrane (WRB)
Tape (AB)
COMMERCIAL STEEL FRAME CONSTRUCTION UP TO .\WEB RGB ROCKWOOL™ logo - Primary Colour.png
June 11 2020 4:23 PM
* For thermal performance of ROCKWOOLTM products, please refer to ROCKWOOLTM technical data sheets
** For climate zone specific considerations for thermal, air and vapor control layer properties and requirements, please contact ROCKWOOLTM Building Science for support.
Pre-finished parapet
Self-adhered membrane to slope
cap flashing c/w wind
lap from roof membrane, up clips, both sides, for
over parapet (WRB) attachment
min. 2"
Fill void with ROCKWOOL
COMFORTBATT®
Roofing membrane
Insect screen (perforated
installed as per
rigid metal sheet)
manufacturers instructions
(2-ply SBS illustrated) Lap parapet cap
membrane over wall
212" (64mm) ROCKWOOL WRB
TOPROCK® DD insulation
Exterior gypsum
board decking Vapor permeable
membrane (AB/WRB)**
Pre-strip membrane
under parapet lapped
and adhered onto wall
sheathing membrane Exterior gypsum
(AB) board sheathing
Steel decking
COMMERCIAL STEEL FRAME CONSTRUCTION UP TO .\WEB RGB ROCKWOOL™ logo - Primary Colour.png
June 11 2020 4:23 PM
TM TM
* For thermal performance of ROCKWOOL products, please refer to ROCKWOOL technical data sheets
** For climate zone specific considerations for thermal, air and vapor control layer properties and requirements, please contact ROCKWOOLTM Building Science for support.
Composite metal panel
cladding system over
vertical metal hat
Fill space with tracks fastened to steel
ROCKWOOL studs
COMFORTBATT® Air space
Self adhesive
through-wall flashing
Acoustic caulking membrane w/ sealant at
top edge (WRB)
(Optional)
Fill cavity with 6"
(150mm) ROCKWOOL Insect screen (perforated
COMFORTBATT® rigid metal sheet)
[312" (89mm)
ROCKWOOL Metal cross-cavity
COMFORTBATT® also flashing c/w end dams
available]
Vapor permeable
Vapor control layer** membrane (AB/WRB)**
Tape (AB)
6" steel stud framed wall
COMMERCIAL STEEL FRAME CONSTRUCTION UP TO .\WEB RGB ROCKWOOL™ logo - Primary Colour.png
June 11 2020 4:23 PM
TM TM
* For thermal performance of ROCKWOOL products, please refer to ROCKWOOL technical data sheets
** For climate zone specific considerations for thermal, air and vapor control layer properties and requirements, please contact ROCKWOOLTM Building Science for support.
Sealant joint from Double glazed thermally
window frame to broken window
membrane for air (aluminum illustrated)
continuity
COMMERCIAL STEEL FRAME CONSTRUCTION UP TO .\WEB RGB ROCKWOOL™ logo - Primary Colour.png
June 11 2020 4:23 PM
TM TM
* For thermal performance of ROCKWOOL products, please refer to ROCKWOOL technical data sheets
** For climate zone specific considerations for thermal, air and vapor control layer properties and requirements, please contact ROCKWOOLTM Building Science for support.
Gypsum board c/w 2
layers latex paint
Continuous backer
rod and sealant
Air space
COMMERCIAL STEEL FRAME CONSTRUCTION UP TO .\WEB RGB ROCKWOOL™ logo - Primary Colour.png
June 11 2020 4:23 PM
TM TM
* For thermal performance of ROCKWOOL products, please refer to ROCKWOOL technical data sheets
** For climate zone specific considerations for thermal, air and vapor control layer properties and requirements, please contact ROCKWOOLTM Building Science for support.