PC1600

Mppt Solar Charge Controllers


PC16-4015F/5015F/6015F

PV Input : 70V~150VDC
Nominal Batterry Voltage : 24V / 48V
Output Voltage : 22.0-28.6VDC / 44V-57.2VDC
Maximum Output Current : 40A / 50A / 60A
Efficiency : ≥97%
Environmental temperature : -10℃ --45℃
Alarm Protections : Output Short Circuit Protection, Battery Protection
Display : LED + LCD

www.mustups.net
A charge controller’s main job is to optimize a PV array’s output
which can fluctuate based on shading and temperature variables
found on the average roof.
Must™ PC1600 Charge Controllers truly represent innovation in
Maximum Power Point Tracking (MPPT) technology, which enables
them to increase the yield from a solar photovoltaic (PV) array as
much as 30% over conventional designs. PC1600 Charge
Controllers support a wide variety of system designs, battery
chemistries, and integrate seamlessly in terms of system data
management and programming.
The innovative PC1600 MPPT software algorithm is both continuous
and active, increasing photovoltaic array power yield up to 30%
compared to non-MPPT controllers. Thanks to active cooling and intelligent thermal management
cooling, both PC1600 Charge Controllers can operate at their full maximum current rating,40 amps or
60 amps respectively, in ambient temperatures as high as 113°F (45°C).
PC1600 Charge Controllers incorporate the features developed by Must™, including support for a wide
range of nominal battery voltages and the ability to step-down a higher voltage solar array to recharge a
lower voltage battery bank. A built in, backlit 70-character display shows the current status and set the
key parameter at the touch of a button.

Saving money when the sun shines, saving much more when it’s not
PV system designers met the challenge of delivering both grid-tied savings during normal times and off-
grid independence during emergencies with 1-phase arrays of Must IPV3000W/IPV5000W
inverter/chargers powering your house. This system saved money on utility bills, supply essential power
during emergencies (all with one versatile system).
Charge Controller Working Stage Transition Definitions
The PC1600 has a 4-stage battery charging algorithm for rapid, efficient, and safe battery charging.
Absorption Absorption Float Float
Voltage CC CV CC CV Wait
Float Float
Wait
CC CV

Float Charging
Voltage

Refloat CHarging
Voltage

Absorption
Voltage

Current
Max Current

Absorption
Current

Float Charging
Current
Timer

Display & Operation


Operation and display panel is in the front panel of the charge controller. It includes three indicators,
four function keys and a LCD display, indicating the operating status and input/output information.

LED indicator
LED indicator System status
On PV voltage normal
Flashing every 1s PV fault is recovering
PV Green
Flashing every 2s PV fault can’t recover
Off PV is off
On Battery voltage normal
Flashing every 1s Battery fault is recovering
BATT Yellow
Flashing every 2s Battery fault can’t recover
Off Battery is off
Flashing Fault
FAULT Red
Off Normal

Function keys
Function key Description
MENU Enter or exit setting mode.
INC Increase the setting data.
DEC Decrease the setting data.
ENTER Confirm the selection in setting mode.
LCD Display Indication

Indication Function description


Display Information

Indicates PV voltage, battery voltage.

Indicates output current, output power.

Indicates battery type ,battery capacity by 0-24%,25-49%,50-74% and


75-100% in charging status.

Indicates MPPT solar charge controller work pattern.

Warning Information

Indicates the error codes.

Configuration Program

Indicates the setting programs.


Operating Mode Description
Operation mode Description LCD display
01 Mppt charging

02 Current-limiting output
charging

03 PV is unavailable

04 PV stop charging

LCD Setting
After pressing MENU button ,the unit will enter setting mode. Press “INC” or “DEC” to make modifiable
parameter increase or decrease progressively .And then, press “ENTER” to confirm the selection.

Program Description Selectable option


01 Working switch and Permit work Lead acid battery
Battery type

Forbide work Lithium battery

02 Battery AH and Battery AH Absorption voltage


Absorb voltage

03 Refloat charging Refloat charging voltage Float charging voltage


voltage and Float
charging voltage

04 Max current and Max current absorption current


absorb current

05 Low battery voltage Low battery voltage High battery voltage


and High battery
voltage

Operation data display

Setting information LCD display


PV voltage and charging power

Battery voltage and battery current

Error Code

Fault Code Fault Cause LCD Indication


01 Battery voltage class error

02 Hardware protection

03 Over current

04 Battery voltage is too low


05 Battery voltage is too high

06 Current is uncontrollable

07 Over temperature

08 Current sensor error

09 PV voltage is too high

10 Fan fault
Model PC16-4015F PC16-5015F PC16-6015F
Charge Input
Maximum Open Circuit Voltage of
70V ~ 150V
Solar Module
Storage Battery
Nominal Voltage 24V / 48V
Float Voltage 27.4V / 54.8V
Over Charge Voltage 28.6V / 57.2V
Lack of Voltage 21.0V / 42.0V
DC Output
Output Voltage 22.0-28.6V / 44V-57.2V
Maximum Output Current 40A 50A 60A
Prompt for cutting voltage 23.0V / 46.0V
Cutting for lack of voltage 21.6V / 43.0V
LV resumption 26.0V / 46.0V
Display
Systematic operation, LV indication, LV protection, over charge protection,
LED indication
loads protection, short circuit protection
Charge voltage, charge current, voltage of storage battery, capacity of storage
LCD display
battery, output current
Alarm Protections
Output short circuit protection Yes

LV protection for storage battery Yes

Other Items

Defend rank In compliance with regulations of DIN EN60529 and standards of IP22 or IP65

PWM ,constant current—constant voltage, function of automatic protection for


Charge mode
storage battery
Radiating mode Fan cooling
Working mode General controller
Efficiency ≥97%
Self electricity consumption < 10 mA < 15mA
Environment
Environmental temperature -10℃ --45℃
Ambient humidity 0--90%,No dew
Altitude ≤4500m