TAC MicroNet™
MN 110 and 130 Series Controllers

The TAC I/A Series MicroNet 110 and 130 Controllers are programmable, interoperable
controllers designed in accordance with LonMark® guidelines. When programmed
using TAC WorkPlace Tech Tool (WP Tech), these controllers provide control for fan coil
and unit ventilator applications. These controllers feature: screw terminal blocks; three
universal inputs; three high-voltage relay outputs (only one for the MN 110); four 24 Vac
• One or three high-voltage relay outputs Triac (digital) outputs; and an S-Link interface for connection to an optional MN-Sx TAC
capable of directly powering typical 240 Vac, I/A Series MicroNet Sensor.
3 A motors.
The MN 110 and 130 controllers conform to the LonMark Fan Coil Unit functional
• Uses the LonMark Fan Coil Profile 8020 for
profile (8020), providing open communication and interoperability with third party
interoperability.
LonMark devices, and greater freedom in system design. These controllers can function
• Capability to function in standalone mode in standalone mode or as part of a LonWorks® TP/FT-10 Free Topology network.
or as part of a LonWorks TP/FT-10 Free
Topology communications network. Especially suitable for new or existing system installations, the MN 110 and 130
• Onboard LED indication without cover controllers provide control for fan coil units and unit ventilators with direct connection(s)
removal. to one, two, or three electrical loads such as fans, pumps, relays, or electric heat, at up to
240 Vac at 3 A.
• Compact size allows mounting in confined
spaces.
MN 110 and 130 controllers offer the advantages of either standalone or network
• Four 24 Vac Triac outputs. control. Support is also provided for an optional MN-Sx TAC I/A Series MicroNet Sensor
• Can be directly mounted on a wall, or on a (see the table, “Inputs from MN-Sx TAC I/A Series MicroNet Sensor,” on page 3, for
DIN rail, within a suitable grounded metal features).
enclosure. The TAC WorkPlace Tech Tool may be used to program the MN 110 and 130 controllers
through the LonWorks network jack on either the controller or a connected MN-Sx
• Built-in jack for connection to a LonWorks
sensor.
network.
Software Capabilities Table-1 Model Chart.
• Allows design of a complete custom
application for each controller.
Model Description Inputs/Outputs Profiles

• Conforms to the LonMark guidelines.


3 Universal Inputs (UI)
• TAC WorkPlace Tech Tool is capable of
reconfiguring and editing application TAC I/A Series MicroNet 1 Line Voltage Relay Output
configuration data. MNL-11RFx Fan Coil
MN 110 Controller (DO)
• Interoperability achieved through use of the
LonMark Fan Coil Profile 8020. 4 Triac Outputs (DO)

3 Universal Inputs (UI)

TAC I/A Series MicroNet 3 Line Voltage Relay Outputs


MNL-13RFx Fan Coil
MN 130 Controller (DO)

4 Triac Outputs (DO)


Table-2 Inputs from MN-Sx TAC I/A Series MicroNet Sensor.

Inputs Description MN-Sx Sensor

MN-S1, MN-S1HT, MN-S2, MN-S2HT, MN-S3, MN-S3HT,


Space Temperature 32 to 122 °F (0 to 50 °C) MN-S4, MN-S4HT, MN-S4-FCS, MN-S4HT-FCS, MN-S5 and
MN-S5HT
MN-S1HT, MN-S2HT, MN-S3HT, MN-S4HT, MN-S4HT-FCS,
Space Humidity 5 to 95% RH, Non-condensing
and MN-S5HT
MN-S3, MN-S3HT, MN-S4, MN-S4HT, MN-S4-FCS, MN-
Adjustable Setpoint 40 to 95 °F (4 to 35°C)
S4HT-FCS, MN-S5, and MN-S5HT
For standalone occupancy
control or remote status MN-S2, MN-S2HT, MN-S3, MN-S3HT, MN-S4, MN-S4HT,
Override Pushbutton
monitoring of local status MN-S5, and MN-S5HT
condition
Fan Operation and Fan mode selection: On, Speed MN-S4, MN-S4HT, MN-S4-FCS, MN-S4HT-FCS, MN-S5, and
Speed (Low/Medium/High), or Auto MN-S5HT
System mode selection: Heat,
System Mode MN-S4, MN-S4HT, MN-S5, and MN-S5HT
Cool, Off, or Auto
Emergency heat mode selection:
Emergency Heat MN-S5 and MN-S5HT
Enable or Disable

Communications
LonWorks Networks
A LonWorks communications network uses an TP/FT-10 Free Topology configuration. Controllers on a LonWorks net-
work can communicate with each other in a peer-to-peer fashion. A LonWorks network has a communications speed of
78k baud, using unshielded, twisted-pair cabling, with connections that are not polarity sensitive.

S-Link
The Sensor Link (S-Link) communications wiring provides power and a communication interface for an MN-Sx TAC I/A
Series MicroNet sensor. The various MN-Sx sensors can provide room temperature, room humidity, setpoint adjust-
ment, and occupancy override. This connection uses two-wire, unshielded cable and is not polarity sensitive. Maximum
wire length allowed between a controller and a TAC I/A Series MicroNet Sensor is 200 ft (61 m).

2
SPECIFICATIONS
Hardware Specifications Agenc y Listings Platinum
Dimensions FCC -40 to 240 °F (-40 to 116 °C), TAC
4.2 H x 6.1 W x 2 D in. (107 x 154.9 x Class B. model TSMN-58011, TS-5800 series or
50 mm). equivalent.
UL
Enclosure UL-873 (File #E9429) Recognized Com- 1K Resistance
Molded ABS plastic case. Fire resistant ponent. 0 to 1.5K ohms.
to UL94VO.
UL Recognized Canadian Component.. Analog Voltage
Power Supply Input Range 0 to 5 Vdc.
24 Vac +25/-15%, 50/60 Hz. Australia
Meets requirements to bear the C-Tick Analog Current
Maximum Power Consumption Mark. Range 0 to 20 mA requires an external
MNL-11RFx
European Community – EMC Directive 250 ohm shunt resistor.
20.5 VA @ 24 Vac, 50/60 Hz (8.5 VA
plus maximum DO1-DO4 total load of 89/336/EEC
Digital
0.5 A or 12 VA). EN61326.
Dry switched contact (N.O. or N.C.).
Low-Voltage Directive – 73/23/EEC Detection of closed switch requires
MNL-13RFx
EN60730-1. less than 300 ohms. Detection of open
21.5 VA @ 24 Vac, 50/60 Hz (9.5 VA
switch requires more than 1.5 K ohms.
plus maximum DO1-DO4 total load of Ambient Limits
0.5 A or 12 VA). Operating Temperature Line Voltage Relay Outputs
-40 to 131 °F (-40 to 55 °C). MNL-11RFx (1)
Surge Immunity Compliance
3 A maximum at 240 Vac, cos Ø = 0.4.
IEEE C62.41 (IEEE-587, Category A & Shipping and Storage Temperature Form A (SPST — normally open).
B). -40 to 160 °F (-40 to 71 °C).
MNL-13RFx (3)
Mounting Humidity 3 A maximum at 240 Vac, cos Ø = 0.4.
Wall or 35 mm DIN rail, within a suit- 0 to 95% RH, non-condensing. Form A (SPST — normally open).
able grounded metal enclosure.
Wiring Terminals
Screw terminal blocks. Low voltage Triac Outputs (4)
screw terminals (all except high-volt- Digital outputs for switching 24 Vac
age terminals) accept a single AWG #18 (0.5 A or 12 VA maximum total load for
(0.823 mm2) or smaller wire. High-volt- DO1-DO4 @ 24 Vac).
age screw terminals (DO5, C5, DO6,
C6, DO7, and C7) accept a single AWG
#14 (2.08 mm2) or smaller wire. WARNING :
This controller is not suitable for ex-
Universal Inputs (3) posed mounting on a wall or panel, or in
Universal Input characteristics are soft- any other easily accessible place due to
ware-configured to respond to one of the possibility of personal contact with
the following input types: the mains terminals. It must be mounted
10K Thermistor with 11K Shunt Resistor inside a suitable grounded metal enclo-
Sensor operating range -40 to 250 °F sure.
(-40 to 121 °C), TAC model TSMN-
57011-850, TS-5700-850 series or
equivalent.

10K Resistance
0 to 10.5K ohms.

Balco
-40 to 250 °F (-40 to 121 °C), TAC
model TSMN-81011, TS-8000 series or
equivalent.

3
PDA
TAC MicroNet Sensor
Desktop PC or (MN-S5 Shown) 5
Notebook PC with
TAC WorkPlace Tech MN 130 or MN 110 4 MNL-V3RVx
Tool Software Controller or MN 50 UNC Controller
1 2
3 Controller

This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
interference that may cause undesired operation.
device may DECONNECTER
This device conforms with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
not cause harmful interference,AVANT

DI SCONNECT POWER BE FORE SERVI CI NG.


I NTERCONNECT SEPARATE CLASS 2 C I RCUI TS.
RI SK OF ELECTRI CAL S HOCK OR FI RE. DO NOT

C5
DO5

DO5: 250VAC, 3A Max, COS f = 0.4.


and (2) This device

DO1-DO4: 24VAC, 0.4A Max Total Load.


S-LK: 16VDC Max, Class 2.
UI: 5VDC Max, Class 2.
Ambient Temp: -40°C to +60°C
E NTRETEN.

CAUTION

Power: 24VAC, 50/60Hz, Class 2,


must accept any interference received, including

Regulating Equipment
N2223

Temperature indicating and

8.5VA + DO1-DO4 loads.

DO4
24VAC
DO3
DO2
24VAC
DO1
SW

E9429
24H

934G
SW 3
24H
SW 2
24H

MNL-CIM

T
I
M
X
24H 1

V
C
E
R
C
V

SRVC
24G

R
S

LON
J1
GN

LON
AO

S-LK
D

S-LK

COM 0V

COM 0V
UI1
UI

MNL-11RF2
I/A Series
S-L
K/C DI

UI2

24VAC
OM

UI3
S-L

GND
K

0V
TAC MicroNet Controller
LO
N
LO
N

Interface Module

LONWORKS Router 6
Network (if required) I/A
MN
Se
rie
80
0

MN 100, MN 150, or MNL-V1RVx or 4


MN 200 Controller MNL-V2RVx MN 800 TAC MicroNet Sensor
Controller Controller (MN-S3 Shown)

1 A PC can be connected to the LONWORKS TP/FT-10 Network, either directly or through the LONWORKS® network jack of a
LONWORKS controller or MN-Sxxx Wall Sensor. The PC must have an Echelon® LonTalk® adapter card.
2 Programming any of the TAC I/A Series controllers, or the TAC I/A Series MN 800 controller, requires TAC WorkPlace Tech
Tool.
3 This controller is not suitable for exposed mounting on a wall or panel, or in any other easily accessible place due to the
possibility of personal contact with the high-voltage terminals. It must be mounted inside a suitable grounded metal enclosure.
4 TAC MicroNet Sensors can be connected to any MN controller.
5 A PDA running the Pocket TAC I/A interface software may be used to communicate with TAC MicroNet I/A Series controllers.
6 When routers are used, WP Tech is able to communicate through them to any of the TAC I/A Series devices on the network.

TAC MicroNet Sensor MN 130 or MN 110 MN 800


(MN-S5 Shown) Controller MN 100, MN 150, or Controller
3 MN 200 Controller
I/A

4
Se
MN rie
80
0

This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
interference that may cause undesired operation.
device may DECONNECTER
This device conforms with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
not cause harmful interference,AVANT

DI SCONNECT POWER BE FORE SERVI CI NG.


I NTERCONNECT SEPARATE CLASS 2 CI RCUI TS.
RI SK OF ELECTRI CAL SHOCK OR FI RE. DO NOT

C5
DO5

DO5: 250VAC, 3A Max, COS f = 0.4.


and (2) This device

DO1-DO4: 24VAC, 0.4A Max Total Load.


S-LK: 16VDC Max, Class 2.
UI: 5VDC Max, Class 2.
Ambient Temp: -40°C to +60°C
ENTRETEN.

CAUTION

Power: 24VAC, 50/60Hz, Class 2,


must accept any interference received, including

Regulating Equipment
N2223

Temperature indicating and

8.5VA + DO1-DO4 loads.

DO4
24VAC
DO3
DO2
24VAC
DO1
E9429
934G

TAC I/A Series


T
I
M
X
V
C
E
R
C
V

SRVC
R
S

LON
J1

LON
S-LK
S-LK

COM 0V

COM 0V
UI1

MNL-11RF2
I/A Series
UI2

Enterprise Server
24VAC
UI3

LONWORKS
GND
0V

Network

6 Router
CLO
SE

(if required)
OP 24G
EN
SW 24G
24H
SW 3
24H
SW 2
24H
24H 1
24G
GN AO
D CO
M
UI
S-L
K/C DI
OM
S-L
K
LO
N

Ethernet
LO
N

4
MNL-V1RVx MNL-V3RVx TAC MicroNet Sensor
or MNL-V2RVx or MN 50 (MN-S3 Shown)
UNC Controller Controller
Controller

Figure-1 TAC I/A Series MicroNet MN110 and 130 Controller Connectivity.

Copyright © 2006, TAC TAC Distributed, manufactured, and sold by TAC. I/A SERIES trademarks are owned
All brand names, trademarks and registered trademarks are 1354 Clifford Avenue by Invensys Systems, Inc. and are used on this product under master license
the property of their respective owners. Information contained PO Box 2940 from Invensys. Invensys does not manufacture this product or provide any
within this document is subject to change without notice. Loves Park, IL 61132-2940 product warranty or support. For service, support, and warranty information,
All rights reserved. contact TAC at 1-888-444-1311.
www.tac.com
F-27040-3

You might also like