Professional Documents
Culture Documents
Air System Inputs
Air System Inputs
Air System Inputs
1. General Details:
Air System Name Air system
Equipment Type Packaged Rooftop Units
Air System Type Single Zone CAV
Number of zones 1
3. Zone Components:
Space Assignments:
Zone 1: Zone 1
Bedroom 1 B+D FF x1
Bedroom 2 B+D FF x1
Bedroom1 FF x1
Bedroom2 FF x1
Entertainment Room FF x1
GYM GF x1
Half Bath GF x1
Living Room GF x1
Living Room SF x1
Living+Dining FF x1
Main Kitchen FF x1
Main Kitchen GF x1
Main Kitchen SF x1
Master Bed FF x1
Master Bed SF x1
Masterbed B+D FF x1
Masterbed B+D GF x1
Masterbed B+D SF x1
Masterbed GF x1
Movie Room FF x1
Office GF x1
Servant Bath FF x1
Servant Room FF x1
Servant Room GF x1
SR Kitchen GF x1
SR Living FF x1
Stairs Area GF x1
Safety Factors:
Cooling Sensible 0 %
Cooling Latent 0 %
Heating 0 %
5. Equipment Data
Central Cooling Unit - Air-Cooled DX
Estimated Maximum Load 264.1 MBH
Design OAT 95.0 °F
Equipment Sizing (Auto-Sized) 264.1 MBH
Capacity Oversizing Factor 0 %
ARI Performance Rating 11.000 EER
DX System Configuration 1-stage compression, 1 circuit
Conventional Cutoff OAT 55.0 °F
Low Temperature Operation Used
Low Temperature Cutoff OAT 0.0 °F