One-Component Aliphatic Moisture Cure Coating Formulation # GP97-001

You might also like

Download as rtf, pdf, or txt
Download as rtf, pdf, or txt
You are on page 1of 2

Bayer Corporation

100 Bayer Road


Pittsburgh, PA 15205-9741
Phone:412 777-2000

One-Component Aliphatic Moisture Cure Coating


Formulation # GP97-001
(formerly #2604)

This formulation cures rapidly in the presence of atmospheric moisture to form a tough,
abrasion resistant finish. It is suitable for use on floors over epoxies and other coatings.

Weight Volume
Raw Materials Weight Volume Solids Solids Supplier

Desmodur N-75 529.71 59.99 396.75 41.99 BAYER


Aromatic 100 271.29 35.46 0.00 0.00
Dabco T-12 (a) 16.93 2.03 1.69 0.20 Air Products
CAB 381–0.1 (a) 21.12 2.52 2.11 0.25 Eastman
Total 839.05 100.00 400.55 42.44

(a) 10% in PM Acetate

The addition of 1% each of Tinuvin 292 and Tinuvin 1130 (based on resin solids) should be
considered for outdoor applications.

Formulation Characteristics
Weight Solids, % 47.74
Volume Solids, % 42.44
Weight per gallon, lbs 8.39
VOC, lbs/gal 4.29
Formulation #GP97001
Page 2

Test Data
Brookfield viscosity, ASTM D-2196-84, 22°C, cps 40

Gardner Circular Dry Times, (hrs., 22°C and 68% RH)


ST 0.3 HD 3.3
SD 1.6 MF 4.0

Impact, inch – lbs. ASTM D-2794-84


direct 140 reverse40

Pencil Hardness ASTM D-3363-84 2H

Taber Abrasion, ASTM D-4060-84, CS-17 wheel, 1000 g load, 1000 cycles, mg loss 8.4

Four Hour Spot Tests


IPA 5 50% NaOH 5 50% H2SO4 4
MEK 5 50% NH4OH 5 37% HCl 2
Toluene 5 Aniline 4 100% Acetic 1

5 = No Efffect
4 = Stain Only
3 = Blistering
2 = Lifting
1 = Failure

12/98

The conditions of your use and application of our products, technical assistance and information (whether verbal, written or by way of production
evaluations), including any suggested formulations and recommendations, are beyond our control. Therefore, it is imperative that you test our products,
technical assistance and information to determine to your own satisfaction whether they are suitable for your intended uses and applications. This
application-specific analysis at least must include testing to determine suitability from a technical as well as health, safety, and environmental standpoint.
Such testing has not necessarily been done by Bayer. All information is given without warranty or guarantee. It is expressly understood and agreed that
customer assumes and hereby expressly releases Bayer from all liability, in tort, contract or otherwise, incurred in connection with the use of our products,
technical assistance and information. Any statement or recommendation not contained herein is unauthorized and shall not bind Bayer. Nothing herein
shall be construed as a recommendation to use any product in conflict with patents covering any material or its use. No license is implied or in fact granted
under the claims of any patent.