Experiment No. :2
m
er as
of Separately Excited DC Generator
co
eH w
o.
: 30/07/2020
Date of Experiment
rs e
ou urc
: L51+52
o
Slot
aC s
vi y re
1
This study source was downloaded by 100000830770231 from CourseHero.com on 09-20-2021 11:10:08 GMT -05:00
https://www.coursehero.com/file/68194495/Exp-2-OCCLOAD-Char-of-DC-Generatorpdf/
Circuit Diagram – Open Circuit Characteristics & Load Test
a
vi
ed
ar
sh
as
w
m e
co rc
o. ou
er res
se dy
stu
2
H
s
hi
This study source was downloaded by 100000830770231 from CourseHero.com on 09-20-2021 11:10:08 GMT -05:00
Exp. No. 2 Date: 30/07/2020
OBJECTIVE
To perform the open circuit & load test on separately excited D.C Generator and draw the open
circuit, internal and external characteristics.
APPARATUS REQUIRED
m
MC 0-220V, 0-440V 1 each
er as
2
Voltmeter
co
1000ohm, 2A
eH w
Variable 1 each
3 Rheostat 100ohm, 10A
o.
4 Loading rheostat
rs e Variable 50ohm-500ohm 1 No.
ou urc
5 Tachometer Digital 0-3000rpm 1 No.
o
aC s
THEORY
vi y re
A d.c. generator whose field winding is supplied current from an external d.c sources are called
separately excited d.c generator. The flux produced by the poles depends upon the field current
poles (i.e., If). But in the
ed d
saturated region the flux becomes nonlinear. Its conventional diagram is shown in Fig - 1
is
If Ia
Th
F1
A2
Voltage
DC G
sh
SUPPLY A1
F2
3
This study source was downloaded by 100000830770231 from CourseHero.com on 09-20-2021 11:10:08 GMT -05:00
https://www.coursehero.com/file/68194495/Exp-2-OCCLOAD-Char-of-DC-Generatorpdf/
TABULAR COLUMN:
If
S.NO E0 volts (increase)
Amperes
1. 0 9
2. 0.21 81
3. 0.42 149
4. 0.63 211
5. 0.82 265
6. 1.04 310
7. 1.25 346
8. 1.46 373
9. 1.67 394
m
10. 1.88 409
er as
11. 2.08 423
co
12. 2.29 439
eH w
13 2.5 462
o.
14
rs e
2.71 498
ou urc
Name: Nathan Shankar
Regno: 19BEE0381
o
500
ed d
400
ar stu
Eo Volts
300
is
200
Th
100
sh
0
0 2 4 6 8 10 12 14 16
If Amperes
4
This study source was downloaded by 100000830770231 from CourseHero.com on 09-20-2021 11:10:08 GMT -05:00
https://www.coursehero.com/file/68194495/Exp-2-OCCLOAD-Char-of-DC-Generatorpdf/
MODEL GRAPH
E0 INCREASING
Residual
Magnetism
m
er as
o If
co
eH w
Open Circuit Characteristics of a DC generator
o.
rs e
It shows the relation between the no load generator emf in the armature (Eo) and the
ou urc
field current If at a specified speed. Open the field winding of the generator and connect it to a
separate D.C. source through a rheostat shown in Fig - 4
o
aC s
machine at its normal speed and varying the excitation current in steps from zero to maximum
by adjusting field regulating resistance or potentiometer type regulator. The field is supplied
ed d
through a separate source supply. The connection diagram for test is show in Fig - 2
ar stu
A
E0
F1
A1
is
Voltage
DC G V
SUPPLY
Th
A
F Residual
Magnetism
o If
Fig -3 Fig -4
sh
Since the machine is not carrying any armature current, the terminal voltage is the
induced emf in the armature of the machine. The curve of the induced emf against the
excitation current is the magnetization characteristics or open-circuit characteristics of the
machine. After taking the reading of the voltage induced Vs the excitation current by
increasing the current from zero to maximum, readings are taken by reducing the excitation
5
This study source was downloaded by 100000830770231 from CourseHero.com on 09-20-2021 11:10:08 GMT -05:00
https://www.coursehero.com/file/68194495/Exp-2-OCCLOAD-Char-of-DC-Generatorpdf/
from maximum to zero. The curve plotted in Fig -4 shows that while reducing the excitation,
the emf does not follow the same curve and at zero value of excitation, does not return to zero
value but ratains some values of the emf. This emf is due to residual magnetism. This due to
magnetic hysteresis effect. Modern dc machines using steel frames and laminated pole
structure normally have residual magnetism of two to three percent.
Load test
The load test is performed on a d.c. generator to know how it’s terminal voltage changes
with the load (electrical). It is generally assumed that the speed of the generator is maintained
constant by prime mover, during this test. The other purpose of the test also could be to find its
regulation, efficiency and to measure its temperature rise at different loads.
m
er as
TABULAR COLUMN - LOAD TEST
co
eH w
o.
S.NO If ( Amps )
rs e V ( Volts ) IL ( Amps ) Eg = V+IaRa
ou urc
1. 0 439 2.29 439
2. 1.26 436 2.29 438.52
o
435
Armature Current
430
sh
425
420
415
0 1 2 3 4 5 6 7
Voltage(V)
V Eg
6
This study source was downloaded by 100000830770231 from CourseHero.com on 09-20-2021 11:10:08 GMT -05:00
https://www.coursehero.com/file/68194495/Exp-2-OCCLOAD-Char-of-DC-Generatorpdf/
MODEL GRAPH
E0 V I
Generated voltage,
IL, Ia
m
Applications of separately excited generators
er as
co
1. Separately excited generators are preferred where the characteristics of dc shunt
eH w
generator are not up to the expected level.
o.
rs e
2. They can be used to excite the field magnets of ac generators.
ou urc
3. As the drop in voltage is very small, these generators can be used for supplying loads
needing constant voltage.
o
PRECAUTIONS
ed d
PROCEDURE
Open Circuit Characteristics
1. Close the DPST (Double Pole Single Throw) switch connecting supply to field
winding of the Separately Excited DC motor.
2. Increase the Separately Excited DC motor field voltage to rated value (220V).
3. Use variable voltage device to increase or decrease the supply
7
This study source was downloaded by 100000830770231 from CourseHero.com on 09-20-2021 11:10:08 GMT -05:00
https://www.coursehero.com/file/68194495/Exp-2-OCCLOAD-Char-of-DC-Generatorpdf/
4. Close the DPST switch connecting supply to armature winding of the Separately
Excited DC motor.
5. Increase the motor armature voltage to rated value (440V).
6. As Separately Excited DC motor is connected mechanically to Separately Excited DC
generator, so both machines rotate with same speed. Therefore, we can observe speed
of generator in digital tachometer.
7. Now increase the excitation of separately excited generator (VFG).
8. Store this data by clicking “Start Storing Data”.
9. Now again increase the excitation of separately excited generator (VFG).
10. Store this data by clicking “Start Storing Data”
11. Go on repeating this procedure till the rated value of excitation voltage and data is
stored.
12. Now display the data by clicking “Show data”.
m
er as
Load Test On Separately Excited DC Motor
co
eH w
1. Close the DPST (Double Pole Single Throw) switch connecting supply to field
winding of the Separately Excited DC motor.
o.
rs e
2. Increase the Separately Excited DC motor field voltage to rated value (220V).
ou urc
3. Use variable voltage device to increase or decrease the supply
4. Close the DPST switch connecting supply to armature winding of the Separately
Excited DC motor.
o
generator, So both machines rotate with same speed. Therefore, we can observe speed
of generator in digital tachometer.
7. Now increase the excitation of separately excited generator such that o/p of generator
ed d
8. Now connect the load by closing the switch as shown in the figure
9. Note the decrease in voltage of generator and increase in current of generator. As the
load goes on increasing speed and armature voltage of the generator decreases.
is
12. Now again increase the load by closing another load switch.
13. Store this data by clicking “Start Storing Data”
14. Go on repeating this procedure till all loads are connected and data is stored.
sh
8
This study source was downloaded by 100000830770231 from CourseHero.com on 09-20-2021 11:10:08 GMT -05:00
https://www.coursehero.com/file/68194495/Exp-2-OCCLOAD-Char-of-DC-Generatorpdf/
INFERENCE :
• From the experiment we are able to infer in the case of open circuit dc generator there
exists a magnetic field even when the given voltage is 0V, however we observe that
when the graph is plotted for the decreasing voltage there lies a residual magnetism
with a difference of 9V when the voltage is brought down to 0V.
• The load test is performed on a d.c. generator to know how it’s terminal voltage changes
with the load (electrical).
RESULT :
The graphs and observations are noted down for the load test and open circuit characteristic of
a dc generator and then analyzed.
m
Weblinks:
er as
co
http://em-coep.vlabs.ac.in/Exp1/Experiment1.html
eH w
https://www.onlinecharttool.com/
o.
rs e
ou urc
o
aC s
vi y re
ed d
ar stu
is
Th
sh
9