Power Purifiers

You might also like

Download as pdf
Download as pdf
You are on page 1of 5
rosie (led Specification Sheet This specification sheet describes the features, design, and benefits of the Series 800A Power Purification Systems, All sysiems are designed fo assure maximum reliability, flexibility, serviceability, and performance. The ‘overall function of the Series 800A is to receive raw, extremely polluted electrical power and purify it for use by sensitive electronic equipment. The Series 800A is used where isolated, regulated, transient, and noise-free sinusoidal power is required. The 800A is available with output power distribution receptacle, wired flexible cables, and/or flush mounted receptacles. Part No. 621-325 621-376 Input 208/240 V~, 1 phose, 60 He 208/240 Y~, 1 phase, 60 Hz 10 KVA/7 KW, 208/240/120 V~, 7.5 KVA/5.25 KW, 208/240/120 V~, Output 1 Phase, 60 Hz 1 Phase, 60 He Dimensions 15 in, Wx 23.75 in, D x22.50 in. H 15 in, Wx 23.75 in, D x 22.50 in, H Weight 256 Ib 2101. Input Termination 2 Fole, 3 wi »,60.Amp, sealed wire, BAL 2 Pole, 3 wire, 50 Amp, sealed wire, 8 ft L Receptacle Panel Distribution Simplex Receptacle with 2 pole 50 Amp circuit brookor (aty. 1) 621-325 Simplex Receptacle with 2 pole 30 Amp circuit braakor (qty. 2) Duplex Receptacle with 1 pole 15 Amp circuit breaker (ly. 1), Simplex Recoptacle with 2 pole 30 Amp circuit braakor (qty. 1) 621-376. Duplex Receptacle with 1 pole 20 Amp circuit breaker (qty. 2) Standards Systems ore designed and manufactured in accordance with the following: Canadian Standards Association (CSA-C22.2 No. 107.1) ‘of Electrical end Electronic Enginers (IEEE C62.41-1991) Fire Protection Association (NFPA) 70, National Electric Code (NEC) = Underwriters Laboratories (UL 1012, ULS44, CUL) ~ Federal Information Processing Standards Publication 94 (FIPS Pub 94) Major System Components ‘Main Input Circuit “Unit rated for nominal input voltage levels of 208 or 240, single phase, 60 Hz. Input terminals for hard wiring of source conductors and ground are provided. = All units are provided with o pre-installed thermal magnetic input circuit brecker with « molded case. Transformer = Transformers are ferroresonant, dry type, fan air cooled, 600 volt class. + All transformer windings ore closs H (220°C ) insulated copper. © Acass H installation system is uflized throughout with operating temperatures net fo oxcoed 150°C ‘over @ 40°C ambient temperature. = Transformer core manufactured utilizing M-6 grade, grain-oriented, stress relieved transformer steel = Transformer secondary windings ore electrically isolated from primary windings. Newly derived neutral ‘conductor is effectively bonded to cabinet enclosure, ground terminal strip and output neutral terminal str = Allleads, wires and terminals are labeled to correspond with circuit wiring diagram. © Transformers are vacuum impregnated with an epoay resin, “inp rqutement precde zope ouside Noh Aerie: conte LEC for des Performance Specifications Power Output Line Voltage Regulation At 75% load ‘At 50% load ‘At 25% load Immunity to Distortion Load Regulation Voltage Recovery K Factor Power Factor Correction Harmonie Attenuation Isol Lightning and Surge Protection commen Mode Noise Attenuation Transverse Mode Noise Attenuation Ride Through Capability Reliab ‘Audible Noise Efficiency Operating Temperature “Spectictions ond part numbore moy chongo. Consul LECO for latest Information, Form No, 209-208 Single phase, continuous duty rated copacity, Output voltage automatically regulated to within 3% with input voltage fluctuations of +10% fo -20% of nominal under typical load conditions. Meets ‘Computer and Business Equipment Manufacturers Association (CBEMA) voltage regulation requirements. Utilizes Variable Range Regulation (VRR] to ‘obtain improved line vltage regulation when operating under low load conditions. Output voltage automatically regulated fo within 23% or better with input voltage fluctuations of + 10% to -25% of nominal Output voltage automatically ragulated to within 3% with input voltage fluctuations of +10% to -40% of nominal uiput voltage automatically regulated to within £3% or better with input voltage fluctuations of +10% to ~45% of nominal With input voltage distortion of up to 40%, output voltage sine wave contains ‘© maximum harmonic contant of 5%, Output voltage automatically regulated fo within 2.5% whan load chenges from 0% to 100% or 100% to 0%. Output voltage returns to 95% of nominal level within two AC cycles and to 100% within three cycles when the output is taken from no load to {ull load o vice-versa. Recovery from partial load changes are corrected in a shorter period of time. 30, designed to operate with non-linear, non-sinusoidal, high crest factor switch mode power supply type loads without overheating. Input power foctor within 0.95 approcching unity with load power factor os poor os 0.6 ‘Attonvates load generatod odd current harmonics in the order of 23 48. Primory electrically isolated from secondary. Meots isolation criteria ot defined by National Electric Code article 250-54 Attenuates voltage spikes 3000 to 1. Exceeds U/L 1449 rating 330 volts, ‘ANSI / IEEE C62.41 - Category B3. 140 48 12048, With loss of input power for up to 1 cycle, the output sine wave remains at usable AC voltage levels, 200,000 hours (MTBF) ‘At full load, when measured at o three-foot-distance, does not exceed 60 dB, Approximately 92% at fll ood. -20'C to +40°C LECO Corporation 5. Joseph, Bl 49085 + Phone 800-292-6141 » Fax 269-962-6977 Infocom swore "150.9001 2000 Ha Fi 24089» LECO sa vege a rerkel ECO Corportion. Daiverng the Right Result 2no-REVI {© 2010 LECO Corporation REVISION ‘SOLIDWORKS DRAWING Al en sss RELEASE PER ECN 621-376 | A oem EONTROLLED POWER SCOPE: A SERIES 800A POWER PURIFIER REQUIREMENTS: INPUT: 208/240VAC, 1 PHASE, 60Hz_ OUTPUT: 7.5KVAVS.25KW, 208/240/120VAC, 1 PHASE, 60Hz PART NUMBER: DIMENSIONS: 15" W. x 23 3/4" DP, x 22 1/2" SMZX-7.SK-8A ‘WEIGHT: 210LBS RECEPTACLE PANELS: (1) PART NO. 2P3WS0A-FIELD WIRED INPUT TERMINATION (1) PART NO. 16970-L14-30R1-FLUSH MOUNTED SIMPLEX OUTLET RECEPTACLE WITH POLE 9 AMP CIRCUIT BREAKER (1) PART NO, 16970-5-15R2-FLUSH MOUNTED DUPLEX OUTLET RECEPTACLE WITH 1 POLE 15 AMP CIRCUIT BREAKER NOTE: UNIT SHALL MEET U.L, 1012, AND SHALL BE C.U.L. LISTED tt ne ISPECHON CANTERIX: VERIFY OF MAND OEM PART NUMER MARKING: Ca A ATURE IDENTIFICATION AND PART NUMBER MQ BE GN THE PART ANOIOR NON THE NNERHOST PACKAGE preset ies ne |e a Pe ee LECO CORPORATION See [om [om] ve [wor] P | NONE ULSCGO eosoreowne Rrwiatipovedes | oom: ‘eanermo1g | CONODTY CODE DESCRIPTION peo = . ee PURIFIER POWER 50 AMP 7.5 KVA Beemer, [oom —— [ena] pw | oaosaon Groretn era | 00000 ori] mz | 02052010 . SHEET 1 OF 1 voc | oo [eons | MSE 621-376__| A 5 3 4 REVISION B SOLIDWORKS DRAWING 621-325 Bl eon sz OEM PUT ON SOLIDWORKS, WAS CONTROLLED POWER ONL DEAS UPDATED COMPANY SEScrTiON ‘SCOPE: A SERIES 800A POWER PURIFIER REQUIREMENTS: INPUT. 208/240VAC, 1 PHASE, 60Hz OUTPUT: 10KVA/TKW, 208/240/120VAC, 1 PHASE, 60Hz DIMENSIONS: 15° W. x23 34° OP. x 22°12" PART NUMBER: WEIGHT: 2568S MEX-106 8A INPUT TERMINATION. 2POLE, 3 WIRE, 60 AMP, SEALED WIRE, 8 FT. LONG, (2P3W60A) RECEPTACLE PANELS: (1) PART NO. 2P3W6OA-FIELD WIRED INPUT TERMINATION (1) PART NO. 16970-6-50R1 FLUSH MOUNTED SIMPLEX OUTPUT RECEPTACLE WITH 2POLE 60 ANP CIRCUIT BREAKER (2) PART NO. 16970-L14-90R1-FLUSH MOUNTED SIMPLEX OUTLET RECEPTACLE WITH ‘2POLE 30 ANP CIRCUIT BREAKER (1) PART NO. 16970-5-15R2-FLUSH MOUNTED DUPLEX OUTLET RECEPTACLE WITH a ‘POLE 15 ANP CIRCUIT BREAKER ACCEPTANCE AND NOTE: UNIT SHALL MEET ULL. 1012, AND SHALL BE C.UL. LISTED VERIFY O. MAND, OEM PART NUMBER MANUFACTURER'S IDENTIFICATION AND PART NUMBER. ‘TOBE ON THE PART ANDIOR IN/ON THE INNERMOST PACKAGE ar ‘DATE TYPE, ‘SCALE _ cums] P | NONE | (LSS) “HPASRRORATION wooo coe |" PURIFIER POWER6O AMP 10 KVA 107172005 Seporinepneget | 000008 capwz010 8/5) 2/8) 8) 4 RN cK Eepacegoe'ne, | ooo —_Teag on Doc ASIZE SHEET 1 OF 1 621-325 B 1 2 3 4 5 REVISION ‘SOLIDWORKS DRAWING Al en 570 REVISION A RELEASE PER ECN 59470 ‘SCOPE: A SERIES 600A POWER PURIFIER REQUIREMENTS: INPUT: 208/240VAC, 1 PHASE, GOH ‘OUTPUT: 15KVA/10‘5KW, 208/240/120VAC, 1 PHASE, 60Hz DIMENSIONS: 15° W. x23 34" DP, x 22 1/2 WEIGHT: 314 LBS RECEPTACLE PANELS: (1) PART NO. 2P390A-FIELD WIRED INPUT TERMINATION (1) PART NO. 16970-L14.30R1-FLUSH MOUNTED SIMPLEX OUTLET RECEPTACLE WITH 2 POLE 30 ANP CIRCUIT BREAKER (1) PART NO, 16970-5-15R2-FLUSH MOUNTED DUPLEX OUTLET RECEPTACLE WITH 11 POLE 15 ANP CIRCUIT BREAKER (1) PART NO. 16970-6-50R-FLUSH MOUNTED SIMPLEX OUTPUT RECEPTACLE WITH ‘2POLE 50 ANP CIRCUIT BREAKER NOTE: 1. UNIT SHALL MEET ULL. 1012, AND SHALL BE C.UL. LISTED 2 UNIT SHALL INCLUDE EQUIBNENT SAFETY STANDARD LABELING MARKING: (VIN) MANUFACTURER'S IDENTIFICATION AND PART NUVBER, ‘TOBE ON THE PART ANDIOR INION THE INNERMOST PACKAGE. 621-377 | A OEM: CONTROLLED POWER. CONPANY PART NUMBER: SUOXSEA, ‘ACCEPTANCE AND INSPECTION CRITERIA VERIFY O.E.M AND O.EM PART NUMBER pepe aoe | me | (USee) LECO CORPORATION See om [oman] wean | P_| NONE POCORPORATI Jaber wt | 0.00: ~=—— | crx | 0c | 07/08/2011 | COMODITY CODE [DESCRIPTION patoee fl en PURIFIER POWER 50 AMP 15 KVA ES oom —[ona[ am omen \ 1 coo] os amr] | MSIZE SHEET 1 OF 1 621-377 A 1 2 3 7 . or

You might also like