FACTORY & REGD, OFFICE :
PLOTNO. 33, PHAGE I
G.1.D.C. INDUSTRIAL ESTATE
NARODA, AHMEDABAD-382 330. INDIA. se
MODSONIC
mcrae’. (==) QELEeE > INSTRUMENTS
Sinem, (ee MEG. CO. (P) LTD.
MANUFACTURER, EXPORTER AND DISTRIBUTOR OF ULTRASONIC TESTING EQUIPMENT
TMS/UFD/E5468/2019-20 Date 31" January ,2020
TEST AND CALIBRATION CERTIFICATE
PRODUCT : DIGITAL ULTRASONIC FLAW DETECTOR
MODEL/SR.NO : EINSTEIN-II TFT / SR.NO: 5468-9160
SUPPLIED TO : M/s.TURBO NDT & METULLURGICAL SERVICES
Plot.No:8-44 , Nethaji Nagar,Bandlaguda
HYDERABAD- 500 032
|
VALID UPTO + 29.01.2021.
We certify that the above machine was tested and calibrated by us on 30.01.2020 in
accordance with the ASTM-E317-16. Following are the values of the important
parameters evaluated by us.
1. Horizontal Linearity _: Non-Linearity within + 1% (plus/minus one percent) for
0% to 100% FS range.
2. Vertical Linearity: Non-Linearity wi
0% to 100% FS range.
+3% (plus/minus three percent) for
3. Resolution :
(A) Near Surface Resolution : Modsonic Probe Type MM 4SN (10mm dia x 4MHz)
could distinctly resolve a Flat Bottom Hole (FBH) of 8/64” dia (3.125mm dia.) at |
‘a metal distance of 0.2” (5.08mm) from the near surface.
(B) Far Surface Resolution : Modsonic Probe as in 3(A) above could distinctly
resolve a flat Bottom Hole (FBH) of 3/64” dia (1.17mm dia.) at a metal distance
of 0.25” (6.25mm) from far surface.
4. Sensitivity : Modsonic probe as in 3(A) above could distinctly detect a FBH of
1/64” dia in Aluminium block type 1-0300 with the gain 76dB and signal to noise
ratio of 6:1.
in : Modsonic probe type M 2 SN (24mm dia x 2MHz.) gave little more
than 5 (five) full scale reflection and 6" appearing on the Perspex in VI (IIW type)
RefpKEQEE BIRR, with noise level of about 10%
1N1818K