Building 1 · Storey 1 · Room 5 (Light scene 1)


Summary

Ground area: 48.21 m² | Reflection factors: Ceiling: 70.0 %, Walls: 50.0 %, Floor: 20.0 % | Maintenance factor: 0.80 (fixed) | Clearance
height: 2.800 m | Mounting height: 2.800 m 1
Project 0

Building 1 · Storey 1 · Room 5 (Light scene 1)


Summary

Results

Symbol Calculated Target Check Index

Daylight D 1.373 % - - S1

Workplane Ēperpendicular 1625 lx ≥ 500 lx S2

g1 0.10 - - S2

Consumption values Consumption [20 - 32] kWh/a max. 1700 kWh/a

Lighting power density Room 0.24 W/m² - -

0.01 W/m²/100 lx - -

Utilisation profile: DIALux presetting, Standard (office)

Notes on planning:
Daylight proportion for Clear sky (Direct sunlight) on 30/06/2021 at 10.00 (SE Asia Standard Time). The ambient conditions for "Room 5" are clean.

Luminaire list

pcs. Manufacturer Article No. Article name P Φ Luminous efficacy

1 PHILIPS DN130B D165 1xLED10S/830 11.6 W 1147 lm 98.8 lm/W