CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Existing Wall Enhancement Based on 2015 IEBC, ASCE 41-17 & ACI 318-14/TMS 402-16
DESIGN CRITERIA
1. This software is to enhance wall capacity at perpendicular bending and vertical loads. The existing wall can be either concrete wall
or masonry wall.
2. The new concrete and reinforcement can be on both sides, or only one side. Before new concrete/shotcrete, to rough, clear and wet
the existing surface is required.
NEW STEEL YIELD STRESS Fy = 60 ksi, (414 MPa) THE DESIGN IS ADEQUATE.
NEW CONCRETE STRENGTH fc' = 5 ksi, (34 MPa)
THE MAX CONCRETE STRESS b = 0.85 fc' (0.85 on ACI, 1.0 on AISC)
THE MAX CONCRETE STRAINS e max = 0.003 , (ASCE 41-17 10.3.3.1)
ANALYSIS
CHECK FLEXURAL & AXIAL CAPACITY
Pn
800
600
400
Mn .
200
0
0 20 40 60 80 100 120 140 160 180