3.

1
Jenbacher Maintenance schedule
Documentation

Intervals independent of the number of operating hours


Inspection task Number/ Interval Note
section
Daily inspection round I 9002 0 daily Carry out daily visual inspection of the unit.
Operating data log --- daily Log the operating data daily.
If the underpressure increases to more
Intake air filter-Engine IW 8041 A0 daily than 1000 Pa, the filter elements in the pre-
filter and pocket filter should be replaced.
The result of the ignition voltage check to
Check ignition voltage/ weekly be carried out weekly, serves as the
IW 0309 M0
spark plug < 250 oh indicator for the actual service life of the
spark plug.
IW 0101 M0
The results from the engine lubricating oil
TA 1000-0099A first time after
Lubricating oil analyses are decisive for the actual oil
TA 1000-0099B 150 oh
change periods.
TA 1000-0099C
Check the acid level.
Battery TA 1000-0050 once in a month Check if the pole binders are properly
secured.
Check air filter for pollution.
Air filter in switch cabinet --- once in a month
If necessary, clean or replace.
TA 1000-0200
Cooling water TA 1000-0201 once in a year Concentration inspection
TA 1000-0204
30000 oh
after having
W 8080 A0 completed the Cooling water exchange
overhaul
activities
Battery in DIANE module --- every two years Replace
Storage battery at battery
--- every five years Replace
charger

Proper maintenance according to the maintenance schedule is a condition for honouring any claims
under warranty.

After the „Overhaul“ 60000 operating hours, the maintenance work to be carried out is repeated at the
same interval periods.