Climate 5000
FC02-14CC23/1P1L(R)GE| FC02-14CC23/1P2L(R)GE| FC02-14CC23/1P3L(R)GE|
FC02-14CB23/1P1L(R)GE| FC02-14CB23/1P2L(R)GE| FC02-14CB23/1P3L(R)GE|
FC02-14CD23/1P1L(R)GE| FC02-14CD23/1P2L(R)GE| FC02-14CD23/1P3L(R)GE
Read the manual carefully prior to installation and operation of this unit!
• Operating conditions:
Table of Contents
4 Unit installation............................................... 8
4.1 Equipment acceptance .............................. 8
4.2 Installation considerations ......................... 8
4.3 Installation .................................................. 8
4.4 Connection of ventilation duct ................... 9
4.5 Pipeline connection ................................... 9
4.5.1 Connection of chilled water pipeline ... 9
4.5.2 Connection of condensate water
pipeline ......................................................... 9
4.6 Electrical wiring ........................................ 10
4.7 Design and installation of return air case 10
8 Packing list.................................................... 17
9 Appendix ....................................................... 17
occur. Caution:
• DANGER indicates possible risk to life. Please use the fuse with specified
capacity. Do not replace it with
copper wire and iron wire.
Important information
Caution:
Important information in cases where
there is no risk of personal injury or Please connect the cables
material losses is identified by the symbol correctly. Wrong cable connection
shown on the left. It is bordered by may damage electrical
horizontal lines above and below the text. components.
Caution:
Additional symbols
In case there is a fire, shut off
Symbol Meaning main power source and put out
a step in an action sequence the fire with a fire extinguisher
immediately. Confirm whether the
a reference to a related part in the
installation foundation and
document or to other related document
hoisting are secure and reliable.
a list entry If the foundation and hoisting are
- a list entry (second level) not secure and reliable enough,
falling accident may occur.
Table 1: Additional symbols
Warning: Danger:
Be sure to use the product Inappropriate installation may
designated by our company if the lead to fire, electric shock and
goods must be purchased in local personal injury. No modification or
place. repair without permission shall be
allowed.
Warning:
Comply with regulations of local Danger:
electric company when Inappropriate repair may lead to
connecting power supply. fire, electric shock and personal
injury. Be sure to entrust the
Warning: dealer/ professionals with the
repair.
If the unit needs to be moved or
reinstalled, please entrust the
dealer or professionals with the
operation. Pay attention to the following issues:
• This appliance can be used by children aged
Warning: from 8 years and above and persons with
The installation height of unit reduced physical, sensory or mental capabilities
should be no less than 2.5
meters from ground. or lack of experience and knowledge if they
have been given supervision or instruction
Danger: concerning use of the appliance in a safe way
It is forbidden to install in the and understand the hazards involved. Children
place where combustible gas is shall not play with the appliance. Cleaning and
easy to leak. The leakage of
combustible gas may easily user maintenance shall not be made by children
cause fire. without supervision.
• Operate the fan coil within this range:
Danger: - Regarding installation altitude below 1000m;
Ground reliably as per standard - Regarding frequency of supply power within
provisions. Poor grounding may
cause people to get an electric ±1%Hz of rated frequency;
shock. - Regarding electric supply voltage within
+/-10%;
Danger: - Regarding transport / storage temperature
Confirm whether leakage circuit within -25~55°C.
breaker is installed. The circuit
breaker must be installed; • The appliance is not accessible to the general
otherwise electric shock may public.
occur.
2 Product descriptions
The fan coil type air conditioner consists mainly mechanical expansion. This technology enables
of centrifugal fan, coil heat exchanger and other high heat transfer efficiency and adequate
conditioning system for water chilling unit, it is • Large air volume and low noise
wildly used in hotel, restaurant, factory, hospital, With metal volute and centrifugal impeller
exhibition hall, shopping mall and office building featuring many blades available, the fan coil
and other houses with many rooms or comes in many desirable matches between
large-sized industrial and civil buildings required motor and fan to accommodate its needs for
creating a working and living environment which The fan coil is provided with heat exchanger
is full of fresh air, peacefulness and spring-like which permits right and left interchange and
2.1 Product characteristics right, and the interchange can be done easily to
• Safe, reliable and long service life meet the personalized needs of each customer.
test; made of forging brass, the pipes (water 2.2 Applicable models
collecting head) for inlet and outlet water are − FC02-14CC23/1P1L(R)GE
which can run for more than 60000 h without the − FC02-14CB23/1P3L(R)GE
corrosion. − FC02-14CD23/1P3L(R)GE
copper pipe through slit aluminum fins and with CE certificate requirement.
4 Unit installation
► Do not repair before the inspection and
Each fan coil unit is wrapped with corrugated ► If damage is confirmed, contact relevant
box to prevent the unit from damage during personnel for replacement.
inconsistent. Method for connecting with air than 300 m. The hose should be preferably
rubber hose. Connect condensate pipe with Top surface of building for
installation
Ceiling
recommended that the gradient of drain pipe
connect the terminals for high, medium and All lifting holes of the unit shall be provided with
low speeds to three-speed switch (or fan coil booms.
controller);
Warning:
N For high static pressure model unit, be sure to Be sure to wire as per requirements,
otherwise motor may burn out.
connect the terminals for ultrahigh, high and
medium speeds to three-speed switch (or fan Warning:
coil controller); Completely cut off all power devices
during installation work and keep 3mm
N One three-speed switch (or fan coil controller) gap at least.
is designed only to control one fan coil unit.
Climate 5000 8736863650(2017/05) en
11 | Unit installation
Expansion bolt of M8
wide
Lifting
hook M8 hanging bolt
Drain Unit
Return pipe Locking washer
air pipe of M8 wide
Return air Transition air Air
louver pipe discharge Air outlet M8 nut
pipe
− The controller of fan coil is connected with breaker is more than maximum current of all loads.
6 Unit maintenance
• Checklist for Periodical Maintenance If it is necessary to drain all chilled water in heat
N Inspect the shell of unit for pipe from breaks due to expansion arising
corrosion, and clean and set it
right; from freezing.
N Inspect fan blade and scroller ► Do not use to one temperature controller
for damage. Rotate fan blade
manually to verify its smooth or one three-speed switch to control
rotation without obstruction;
Each several fan coil units, otherwise motor may
year N Inspect coil fins for dirt and burn out.
damage;
• Coil cleaning
N Clean and tighten all
connected wires. The fan coil may show degraded cooling
N Drain chilled water from the capacity if it is blocked or dirty. Clean coil as per
whole system, remove fouling
and replace with water. the following steps:
► Disconnect power supply and remove wire ► Connect electricity and water pipe, and
connected with motor, and stop fan blade conduct test run to verify effects.
► Loosen set screw between side plate and better to equip unit with filter screen and clean
and loosen the set screw between fixed The water collector must be clean to facilitate
plate and side plate, Also loose the set removal of condensate water. And it must be
screw between side plate and top cover; cleaned when showing dirt.
use hard nylon bristle to brush and wash - Communication line must be connected to
coil fins, and clear with vacuum cleaner; Terminal Block through fixing clip.
► Reinstall the heat exchanger on fan coil - Communication line adopts metallic hose
screw;
8 Packing list
Packing List
CTN: 1
Model and
Type Name Unit Quantity Remarks
specification
See
Main part Fan coil unit Set 1
nameplate
9 Appendix
Notice:
Correct disposal of this product.
Pay attention to the following issues:
Figure 6: WEEE
Fax: (+86)0533-8552777
Post code: 256404
www.bosch-climate.cn