Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

109 128

53
84
117 60
60 89
129
130
A P R O F O R M A -- A
PLOT AREA CALCULATION
54 110
116
59
59 85
85
88 132 88
131
111
1 Area of the plot 1490.82 SQ.MT.

ROAD 12 M WIDE

ROAD 12 M WIDE
55 115

ROAD 12 M WIDE
ROAD 12 M WIDE
58
87 55 2 Deduction for
134
133 58
87 SOR = 90
114 S a) Road Set - back area
56
57
112
90 PLOT AREA CALCULATION b) Proposed road
86

113 135
137
138 360 = 0.25 o R
c) Any Reservation (sub - plot______)
136

ROAD 12 M WIDE
ROAD 12 M WIDE
ROAD 12 M WIDE
56
57
86 THEREFORE, SR.NO. CALCULATION AREA d) ____% amenity space as per DCR 56/57 (sub-plot___) other
ROAD 12 M WIDE 3 Balance area of plot (1-2) 1490.82 SQ.MT.
489 488
AREA OF SEGMENT SOT Deduction for 15% Recreational ground / 10% Amenity space (if
490
417
416 ROAD 12 M WIDE
= 0.25 * AREA OF CIRCLE A1 1
2 * PR * Ht. = 21 * 54.48* 18.95 516.20 4
deductible for Ind)
ROAD 12 M WIDE

ROAD 12 M WIDE
365

= 0.25 * 3.14 * 7.4 * 7.4 5 Net area of plot (3 - 4) 1490.82 SQ.MT.

ROAD 12 M WIDE
370 368 367
486 369
418
A2 1 1 262.60 6 Additions for floor space index

ROAD 12 M WIDE
487 443
415

364
490
489 488
=42.99 SQ.M. 2 * PR * Ht. = * 54.48 * 9.64
2 2 (a) 100% for D.P. Road
485

419 2 (b) 100% for Set - Back


414
AREA OF TRAINGLE SOT A3 1 605.63
* PS * Ht. = 21 * 51.39 * 23.57

ROAD 12 M WIDE
483 484
2 7 Total areas (5 + 6) 1490.82 SQ.MT.
442
420
= 21 * SR * HEIGHT 8 Floor Space Index Permissible 2.7
482

= 21 * 10.4* 5.2
413
444
441 421
TOTAL 1384.43 9 9(a) FSI credit available by Development Rights
480 487 443 (Restricted to _% of the balance area vide3 above)
481
445
440
= 28.08 DRC No. ____
422

478 479 446


412

THEREFORE, A4 AREA OF ARC 14.91 DRC No. ____


439
484
423
411
AREA OF SEGMENT Additions for floor space index
1399.34 9 (b) 50% as per DCR 32(premium)
477
476 447
438
= 42.99 - 28.08 TOTAL AREA OF PLOT
410 9 (c) 50% as per DCR 33(TDR)
= 14.91 sq.m 9 (d) other
BANDRA TIKA PLAN,MUMBAI 10 Permissible Floor area 4025.21 SQ.MT.
BANDRA TIKA PLAN,MUMBAI PLOT NO. 488+489 11 Existing floor area
12 Proposed Built up area 3978.3 SQ.MT.
LOCATION PLAN LOCATION PLAN 13 Excess balcony area taken in Floor Space Index 35.33 SQ.MT.
14A Purely Residential Built up area 3380.8 SQ.MT.
14B Remaining Non- Residential Built up area 151.6 SQ.MT.
14 Total Built up proposed (14A + 14B ) 3552.4 SQ.MT.
(as per old approved plan dt prior to 06-01-2012)
15 FSI consumed on net holding = 14/1 2.38
B Details of FSI availed acc. DCR31(3)
1 Fungible BuiltUp Area component proposed videDCR
353.3 SQ.MT.
31(3) for purely Residential = or < (14A x 0.35 )
2 Fungible Built Up Area component proposed
vide DCR 35(4)for Non-residential=or< (14Bx0.35) 72.6 SQ.MT.
3 Total Fungible BuiltUp Area videDCR31(3)=(B.1+B.2) 425.9 SQ.MT.
4 Total Gross Built up area proposed (14 + B.3 ) 3978.3 SQ.MT.

ROAD 12 M WIDE C Tenement Statement

S (i)
(ii)
(iii)
Proposed area (item ______ above)
Less deduction of Non Residential area (shop etc)
Area available for tenements [ (i) - (ii) ]
3978.3 SQ.MT.

3978.3 SQ.MT.

T 43.03
SEGMENT
(iv)
(v)
(vi)
Tenements permissible (Density of tenements/h)
Tenements proposed
Tenements existing

D Parking Statement
Total tenements on the plot
30 .

30

10.40 (i) Parking required by Regulation for


Car 50 Total parking
Scooter/ Motor Cycle
53
A4 Outsiders (visitors)
(i) Covered Garage permissible
3

ROAD 12 M WIDE
(i) Covered garages proposed
9.59 Car
Scooter/ Motor Cycle
Outsiders (visitors)

A1
R E Transport Vehicles Parking
(i) Spaces for transport vehicles parking required by Regulations
(i) Total no. of transport vehicles parking spaces provided

PROFORMA B :
23.57
51.39 A2 BASEMENT PLAN, BUA DIAGRAM & FSI CALCULATIONS

28.09

DESCRIPTION OF PROPOSAL OR PROPERTY:


20.58 LAND BEARING C.S.NO.(s) 489,490 BANDRA WEST
54.50 18.95
(AT PERRY ROAD, MUMBAI)

A3
STAMP OF APPROVAL OF PLANS :

DRAWN BY : CHECKED BY :

P 50.30
Q VINAYAK BHARAT CHIPLUNKAR

SIR J.J.COLLEGE OF ARCHITECTURE

SEM VII SCALE:- 1:100 PLATE


NO :

SITE AREA LINE DIAGRAM SC:1:100


ROLL
NO
: 1817 DATE: 09/11/20 3
A P R O F O R M A -- A

1 Area of the plot 1490.82 SQ.MT.


2 Deduction for
a) Road Set - back area
b) Proposed road
c) Any Reservation (sub - plot______)
d) ____% amenity space as per DCR 56/57 (sub-plot___) other
3 Balance area of plot (1-2) 1490.82 SQ.MT.
Deduction for 15% Recreational ground / 10% Amenity space (if
4
deductible for Ind)
5 Net area of plot (3 - 4) 1490.82 SQ.MT.
6 Additions for floor space index
2 (a) 100% for D.P. Road
2 (b) 100% for Set - Back
7 Total areas (5 + 6) 1490.82 SQ.MT.
8 Floor Space Index Permissible 2.7
9 9(a) FSI credit available by Development Rights
(Restricted to _% of the balance area vide3 above)
DRC No. ____
DRC No. ____
Additions for floor space index
9 (b) 50% as per DCR 32(premium)
9 (c) 50% as per DCR 33(TDR)
9 (d) other
10 Permissible Floor area 4025.21 SQ.MT.

ROAD 12 M WIDE 11 Existing floor area


12 Proposed Built up area
13 Excess balcony area taken in Floor Space Index
14A Purely Residential Built up area
3978.3 SQ.MT.
35.33 SQ.MT.
3380.8 SQ.MT.
14B Remaining Non- Residential Built up area 151.6 SQ.MT.
14 Total Built up proposed (14A + 14B ) 3552.4 SQ.MT.
(as per old approved plan dt prior to 06-01-2012)
15 FSI consumed on net holding = 14/1 2.38
B Details of FSI availed acc. DCR31(3)
1 Fungible BuiltUp Area component proposed videDCR
353.3 SQ.MT.
31(3) for purely Residential = or < (14A x 0.35 )
3.0 3.0
2 Fungible Built Up Area component proposed
4.5 vide DCR 35(4)for Non-residential=or< (14Bx0.35) 72.6 SQ.MT.
5.0 5.0 4.9
4.6
6.5 6.7 6.7
3 Total Fungible BuiltUp Area videDCR31(3)=(B.1+B.2) 425.9 SQ.MT.
4.0
4 Total Gross Built up area proposed (14 + B.3 ) 3978.3 SQ.MT.
3.0
6.5 4.7 C Tenement Statement
(i) Proposed area (item ______ above) 3978.3 SQ.MT.
5.8 5.1 (ii) Less deduction of Non Residential area (shop etc)
(iii) Area available for tenements [ (i) - (ii) ] 3978.3 SQ.MT.
(iv) Tenements permissible (Density of tenements/h)
(v) Tenements proposed 30 .
(vi) Tenements existing

ROAD 12 M WIDE
Total tenements on the plot 30
4.4
D Parking Statement
(i) Parking required by Regulation for
Car 50 Total parking
Scooter/ Motor Cycle
Outsiders (visitors) 53
3
5.8 4.4
(i) Covered Garage permissible
(i) Covered garages proposed
6.2 Car
Scooter/ Motor Cycle
Outsiders (visitors)
7.6
E Transport Vehicles Parking
(i) Spaces for transport vehicles parking required by Regulations
(i) Total no. of transport vehicles parking spaces provided
8.9 7.4

12.7 PROFORMA B :
10.2 10.3
BASEMENT PLAN, BUA DIAGRAM & FSI CALCULATIONS
7.4 7.4 7.4 7.4

3.0 4.5

3.0 3.0

DESCRIPTION OF PROPOSAL OR PROPERTY:

LAND BEARING C.S.NO.(s) 489,490 BANDRA WEST


(AT PERRY ROAD, MUMBAI)

STAMP OF APPROVAL OF PLANS :

BLOCK PLAN SC:1:100


DRAWN BY : CHECKED BY :

VINAYAK BHARAT CHIPLUNKAR

SIR J.J.COLLEGE OF ARCHITECTURE

SEM VII SCALE:- 1:100 PLATE


NO :
ROLL : 1817 DATE: 09/11/20 3
NO
LOS AREA CALCULATION
SR.NO. CALCULATION(0.5 X BASE X HEIGHT) AREA A P R O F O R M A -- A

1 0.5 X 6.5 X 1.5 4.875 1 Area of the plot 1490.82 SQ.MT.


2 Deduction for
6.5
2 0.5 X 6.5 X 1.5 4.875 a) Road Set - back area
6.5 1.5 1
1.5
2
0.7
1.5
b) Proposed road
5.8 5.8
4.7
3 0.5 X 5.8 X 7.9 22.91 c) Any Reservation (sub - plot______)
3
d) ____% amenity space as per DCR 56/57 (sub-plot___) other
7.9
9.8
7.9
4 0.5 X 5.8 X 7.9 22.91 3 Balance area of plot (1-2) 1490.82 SQ.MT.
4
Deduction for 15% Recreational ground / 10% Amenity space (if
4.7
4
5.8 1.8 5 0.5 X 7.6 X 3.5 13.68 deductible for Ind)
7.6 5 Net area of plot (3 - 4) 1490.82 SQ.MT.
3.2
5
3.5
8.3
3.5
6 Additions for floor space index
L.O.S. 3.2
6 0.5 X 7.6 X 3.5 13.68
6
1.3 2 (a) 100% for D.P. Road
7.6 7.6

2 (b) 100% for Set - Back


6.7 7 0.5 X 8.9 X 10.2 45.39
8.9
7 Total areas (5 + 6) 1490.82 SQ.MT.
13.7 7
7.2

8 Floor Space Index Permissible 2.7


10.2 10.2
13.5
8 0.5 X 8.9 X 10.2 45.39
9 9(a) FSI credit available by Development Rights
(Restricted to _% of the balance area vide3 above)
8.9 7.4
6.2

15.0
24.0 6.7
8
2.7 9
6.9
8.9
9 0.5 X 6.2 X 3.0 9.3 DRC No. ____
3.0 3.0 9.2 12
2.2 2.7 2.1 2.2
10 2.1
11
DRC No. ____
8.9 6.2 8.9 10 0.5 X 6.2 X 3.0 9.3
Additions for floor space index
9 (b) 50% as per DCR 32(premium)
11 0.5 X 8.9 X 2.2 9.79

L.O.S. SC:1:200 L.O.S. SC:1:200 12 0.5 X 8.9 X 2.2 9.79


9 (c) 50% as per DCR 33(TDR)
9 (d) other
10 Permissible Floor area 4025.21 SQ.MT.
11 Existing floor area
TOTAL 211.89 12 Proposed Built up area 3978.3 SQ.MT.
13 Excess balcony area taken in Floor Space Index 35.33 SQ.MT.
14A Purely Residential Built up area 3380.8 SQ.MT.
14B Remaining Non- Residential Built up area 151.6 SQ.MT.
14 Total Built up proposed (14A + 14B ) 3552.4 SQ.MT.
(as per old approved plan dt prior to 06-01-2012)
15 FSI consumed on net holding = 14/1 2.38
B Details of FSI availed acc. DCR31(3)
1 Fungible BuiltUp Area component proposed videDCR
353.3 SQ.MT.
31(3) for purely Residential = or < (14A x 0.35 )
2 Fungible Built Up Area component proposed
vide DCR 35(4)for Non-residential=or< (14Bx0.35) 72.6 SQ.MT.
3 Total Fungible BuiltUp Area videDCR31(3)=(B.1+B.2) 425.9 SQ.MT.
Total Gross Built up area proposed (14 + B.3 ) 3978.3 SQ.MT.

ROAD 12 M WIDE
4
C Tenement Statement
(i) Proposed area (item ______ above) 3978.3 SQ.MT.
(ii) Less deduction of Non Residential area (shop etc)
(iii) Area available for tenements [ (i) - (ii) ] 3978.3 SQ.MT.
(iv) Tenements permissible (Density of tenements/h)
(v) Tenements proposed 30 .
(vi) Tenements existing
Total tenements on the plot 30
D Parking Statement
(i) Parking required by Regulation for
3.0 3.0 Car 50 Total parking
4.5 Scooter/ Motor Cycle
5.0 5.0 4.9
Outsiders (visitors) 53
4.6 3
6.5 6.7 6.7 4.0 (i) Covered Garage permissible
3.0 (i) Covered garages proposed
6.5 4.7 Car
6.5 Scooter/ Motor Cycle
5.8
5.8
4BHK 5.1
Outsiders (visitors)
E Transport Vehicles Parking
(i) Spaces for transport vehicles parking required by Regulations

3BHK 3BHK (i) Total no. of transport vehicles parking spaces provided

ROAD 12 M WIDE
4.4
PROFORMA B :

BASEMENT PLAN, BUA DIAGRAM & FSI CALCULATIONS

5.8
5.8 4.4
7.6

6.2

L.O.S. 2BHK 2BHK DESCRIPTION OF PROPOSAL OR PROPERTY:


7.6
7.6
LAND BEARING C.S.NO.(s) 489,490 BANDRA WEST
(AT PERRY ROAD, MUMBAI)
8.9
8.9 7.4
13.7
12.7

10.2 10.2 10.3

8.9 7.4 7.4 7.4 7.4


STAMP OF APPROVAL OF PLANS :
3.0 4.5

15.0
24.0
3.0 3.0 3.0
2.2

DRAWN BY : CHECKED BY :

VINAYAK BHARAT CHIPLUNKAR

SIR J.J.COLLEGE OF ARCHITECTURE

SEM VII SCALE:- 1:100 PLATE


NO :
: 1817
BLOCK PLAN SC:1:100
ROLL
NO
DATE: 09/11/20 3
FITNESS CENTER AREA CALCULATION
SR.NO. CALCULATION(0.5 X BASE X HEIGHT)AREA
CAR PARKING STATMENT
8.3
1 0.5 X 3.6 X 1.5 2.7 TOTAL NO OF TENEMENTS PROPOSED
1.5 1.5 2 0.5 X 3.6 X 1.5 2.7 FLAT CARPET AREA NO.S ACCD. TO DC RULE PARKING REQUIRED
1.5
4.5
3.0
3.1 3.6
0.7
3.6 BELOW 45SQ M 0 1 CAR FOR 4 FLTS
3.5 SO. OFFICE 3.9
1 3 4.8 3 0.5 X 4.2 X 2.3 4.83
1 CAR FOR 2 FLATS
3.8
2.3 2 2.3 45 TO 60 SQM 18 9
4
1.0 3.7 4 0.5 X 4.2 X 2.3 4.83 60 TO 90 SQ M 18 1 CAR FOR 1 FLAT 18
4.2
1
8.9 8 3.8 3.8 5 0.5 X 5.3 X 5.6 14.84 ABOVE 90 SQM 9 2 CARS PER FLAT 18
7.9 FITNESS CENTER 2.5 2.9 5
7 2
TOTAL 40 45
5.1 5.6 6 0.5 X 5.3 X 5.6 14.84
3.7
3.7
5% VISITORS 3
4.8
2.6 6 2.6 7 0.5 X 3.7 X 3 5.55 TOTAL CARS REQUIRED 47
4.8

8 0.5 X 3.7 X 3 5.55 TOTAL CARS PROVIDED 47


5.3 5.3

TOTAL 55.84
BIG PARKING PROVIDED 32
SO. OFFICE AREA CALCULATION SMALL PARKING PROVIDED 15
1 0.5 X 4.8 X 3.8 9.12
AREA LINE DIAGRAM FOR
2 0.5 X 4.8 X 3.8 9.12
SO.OFFICE AND FITNESS CENTER SC:1:100
TOTAL 18.24

ROAD 12 M WIDE

3.0 3.0
4.5
5.0 5.0 4.9
4.6
6.5 6.7 6.7 4.0

3.0
6.5 4.7

5.8 5.1

ROAD 12 M WIDE
4.4

5.8 4.4

ROAD 12 M WIDE
6.2

7.6

8.9 7.4

12.7

10.2 10.3

7.4 7.4 7.4 7.4

3.0 4.5

3.0 3.0

BLOCK PLAN
8.3 1.9 15.4 3.0 4.9 8.3 0.7

5.0 BUILDING LINE 4.9

6.5
6.7 6.7

0.0
4.7
6.5
1.5 1.5
4.5

5.8

3.5 SO. OFFICE


3.8

ROAD 12 M WIDE
8.9

2.5
7.9 FITNESS CENTRE 7.9
PROFORMA B :
5.1

METER ROOM
BASEMENT PLAN, BUA DIAGRAM & FSI CALCULATIONS
LOBBY
+300
SD1

4.8
1.2
7.6 4.4
10
1

9
4

RISER=150MM
UP

TRADE=300MM

1.5
7.6
0.3
FW1

3.5 3.1 3.1 3.5


1.5

L.O.S.
23.0
DOWN

0.6
1.0
1.5 DESCRIPTION OF PROPOSAL OR PROPERTY:
19

18

17

16

15

14

13

12

11
20

0.9 6.2
1.2
0.6
LAND BEARING C.S.NO.(s) 489,490 BANDRA WEST
2.8 8.9 2.8
(AT PERRY ROAD, MUMBAI)

13.7

12.7

10.2 10.3 10.2

9.2 1.4 12.9 1.3 9.2 1.3

7.4 7.4
STAMP OF APPROVAL OF PLANS :

15.0

3.0

24.0 2.2

DRAWN BY : CHECKED BY :

VINAYAK BHARAT CHIPLUNKAR

SIR J.J.COLLEGE OF ARCHITECTURE

SEM VII SCALE:- 1:100 PLATE


NO :
: 1817
STILT FLOOR PLAN SC:1:100
ROLL
NO
DATE: 09/11/20 3
BUILT-UP AREA=94.2 BUILT-UP AREA=96.52 BUILT-UP AREA=113.15 BUILT-UP AREA=69.1 BUILT-UP AREA=71.09
RERA CARPET AREA=83.8 RERA CARPET AREA=85.86 RERA CARPET AREA=101.44 RERA CARPET AREA=60.9 RERA CARPET AREA=62.65

ROAD 12 M WIDE
ROAD 12 M WIDE

3.0 3.0
4.5
5.0 5.0 4.9
4.6
6.5 6.7 6.7 4.0

3.0
6.5 4.7

5.8 5.1

ROAD 12 M WIDE
0.7 8.3 1.9 15.4 3.0 4.9 8.3 0.7 4.4

6.1 2.3 3.8 3.5 3.2 1.4 3.4 2.4 3.4 2.6
5.0 4.9
2.0 2.0 2.0 0.6 2.0 5.8 4.4

6.5 6.2
6.7 W1 W1 3.0 TOILET
1.2 3.2 6.7
3.5 3.3 W3 W1 7.6
W1

1.5 W2
DINING
M. BEDROOM 2.1
8.9 7.4

2.0 1.5 M. BEDROOM


D3 1.6 2.0
12.7

3.5 3.6 3.6 4.7 10.2 10.3

6.5
BEDROOM
2.2 3.4 2.1 2.1 3.4 2.2 7.4 7.4 7.4 7.4

W1 W2 W2 W1 3.0 4.5
1.5
0.6 1.3 W3 TOILET D3
5.3 M. BEDROOM D3
TOILET
W3 1.3 0.6
1.5
M. BEDROOM KITCHEN D2 1.3 3.0 3.0

D3
KITCHEN
5.8 1.5 2.0
0.0 1.4
2.8 3.6 3.7 3.7 3.6 2.8
W2
3.0 3.0
1.0 D2 D2 1.0
W4 D2 W4
TOILET 1.6 D3
W3 3.3
DINING 2.4 1.3 DINING
3.8 LIVING 3.4 3.7
2.0 W1
BEDROOM 3.0 BEDROOM W1 2.0
0.6 ROOM D3
M. BEDROOM
D2 3.2 2.0 1.9 D2

TOILET KITCHEN TOILET

ROAD 12 M WIDE
1.2 D2 1.2 2.9 1.2 D2 1.2
D3 W3 W1 W3 3.5 D3
D2
5.8 5.9 D2

BLOCK PLAN
2.8
7.9 0.6 2.0 0.6 7.9
2.2 5.8 3.5 2.2
1.2 1.2 TOILET 1.3 1.3 3.0 TOILET 1.2 1.2
W3 LIVING W3
3.0 ROOM 3.0
1.2
1.5 3.5 0.6 LIVING 0.6 3.5 1.5
D1
4.1 2.0 W1 3.8 ROOM 1.0 D2 D2 1.0 1.2 3.8 W1
2.0 4.1
M. BEDROOM TOILET
TOILET M. BEDROOM
2.4 W3 2.40.6 2.5 2.4 W3 2.4
SD1

D3 D2 1.0 1.2 D3

7.6
0.6 0.6
1.2 D1

1.2
LIVING
0.6 0.6 PROFORMA B :
4.4
1.7 1.8 ROOM 1.8 1.7
10

3.2 3.2
1

9
4

W3 W3 W3 W3
LIVING 2.9
RISER=150MM
UP

TRADE=300MM

TOILET 1.9 TOILET 1.9 ROOM 1.5


1.9 TOILET 1.9 TOILET
B
7.6
M. BEDROOM
D3 0.3 D3
M. BEDROOM B BASEMENT PLAN, BUA DIAGRAM & FSI CALCULATIONS
FW1

2.0 3.3 W1 3.1 3.1 W1 3.3 2.0


3.5 3.5
1.5
2.2

L.O.S.
23.0 1.9
DOWN

D3
7.3 0.6 7.3 D3
D2 1.2 1.0 1.2 D2 1.2
D2 3.5 2.0 1.5
19

18

17

16

15

14

13

12

11
20

1.2
0.9 6.2
1.2
1.8 0.6

BEDROOM KITCHEN DINING DINING KITCHEN


2.6 2.6 2.6 2.6
2.8 8.9 BEDROOM 2.8

2.3 2.3
W1 W1 W1 W1
3.1 3.0 3.0 3.1

2.0 1.4 2.0 2.0 1.4 2.0


DESCRIPTION OF PROPOSAL OR PROPERTY:
13.7

12.7
LAND BEARING C.S.NO.(s) 489,490 BANDRA WEST
3.4 2.4 3.4 2.2 2.5 1.3 7.0 3.4 2.3 3.5

10.2 10.3 10.2


(AT PERRY ROAD, MUMBAI)
1.3 9.2 1.4 12.9 1.3 9.2 1.3

7.4 7.4 7.4

15.0

3.0

24.0 2.2

STAMP OF APPROVAL OF PLANS :

DRAWN BY : CHECKED BY :

VINAYAK BHARAT CHIPLUNKAR

SIR J.J.COLLEGE OF ARCHITECTURE


TYPICAL FLOOR PLAN SC:1:100
SEM VII SCALE:- 1:100 PLATE
NO :
ROLL : 1817 DATE: 09/11/20 3
NO
BUILT-UP AREA CALCULATION
NAME CALCULATION AREA

RECTANGLE

A1 40.2 X 17.6 706.61

DEDUCTION

1 10.9 X 2 21.66

2 0.6 X 1.5 0.97

3 1.9 X 1.8 3.4

4 1.8 X 3.5 6.13

5 3.1 X 2.8 8.41

6 2.9 X 5.2 15.37

7 12.7 X 2.8 35.95

8 4.9 X 3.7 18.17

9 9X2 17.78

ROAD 12 M WIDE 10

11
0.7 X 1.5

1.8 X 3.5
0.98

6.13

12 3.1 X 2.8 8.41

LOBBY

Lo1 2.9 X 3.7 10.76

Lo2 2.2 X 2.4 8.44

Lo3 3.5 X 3.7 12.89

A1 Lo4 5.2 X 2.5 13.12

1
15.4 4.9
LIFT
2.0 2.0
9
10.9
3.7 3.7
8 9.0
0.7
L1 2.5 X 2.6 6.47
1.9

2 1.5

8.3
1.5
1.8 3 1.5
8.3
10
1.5
L2 4.9 X 3.7 5.31
0.6

1.7 1.8
7.2
3.2 2.9 7.9 4.9
STAIRCASE
2.0

3.5 3.5
3.8 ST1 2.5 X 2.6 24.84
5.2 3.2
5.0 5.0
DUCTS

ROAD 12 M WIDE
7.2

7.9
3.0 D2 8.0 3.5 7.9

D3 1.5 D4 1.3
1.5
D1 3.5 X 2.4 8.4
1.5 7.0
3.3

3.5 2.9 2.5 3.5 5.2


1.5

4.0
D2 3.2 X 3 9.6
2.4 D1 2.4 2.5 Lo4 2.7
D5 2.4 2.4
D3 8 X 1.5 11.87
3.5 3.5
Lo1 3.7
3.4 Lo2 3.7
Lo3 3.5 3.5

7.0 1.8 D4 1.5 X 1.3 1.87


6.1

D5 3.5 X 2.4 8.4


4
1.3
ST1 3.7
3.5
3.7

L1 L2
3.6 3.6 3.7
3.5
11
2.6
2.4
D6
2.4
D6 1.3 X 2.4 3.03
3.3 3.5
1.8 7.0 2.5 2.2 3.5
TOTAL 268.36
5.2
6 3.1

5 7 RECT - DEDUCTION 706.61 - 268.36 438.25


2.8 2.8 2.8 2.8 2.8 2.8
12
3.1 9.2 2.9 12.7 7.0 2.2 3.1
NET BUILT-UP FLOOR AREA 438.25

PROFORMA B :

BASEMENT PLAN, BUA DIAGRAM & FSI CALCULATIONS

DESCRIPTION OF PROPOSAL OR PROPERTY:

LAND BEARING C.S.NO.(s) 489,490 BANDRA WEST


(AT PERRY ROAD, MUMBAI)

BUILT-UP AREA LINE DIAGRAM SC:1:100


STAMP OF APPROVAL OF PLANS :

ROAD 12 M WIDE

3.0 3.0
4.5
5.0 5.0 4.9
4.6

: :
6.5 6.7 6.7 4.0

3.0
6.5

5.8
4.7

5.1
DRAWN BY CHECKED BY

ROAD 12 M WIDE
4.4

5.8 4.4
VINAYAK BHARAT CHIPLUNKAR
6.2

7.6

8.9

10.2
12.7

10.3
7.4

SIR J.J.COLLEGE OF ARCHITECTURE


7.4 7.4 7.4 7.4

3.0 4.5

SCALE:- 1:100 PLATE


3.0 3.0

SEM VII
NO :
ROLL : 1817 DATE: 09/11/20 3
NO
BLOCK PLAN
ROAD 12 M WIDE

0.7 8.3 1.9 15.4 4.9 8.3 0.6


CHAJJA BELOW 600 MM WIDE

1.5 1.5

RIDGE
VA
LLE
Y
ROAD 12 M WIDE
RIDGE

RIDGE
RIDGE

EY
3.2

LL
EY

VA
LL
VA

ROAD 12 M WIDE
3.0 3.0

VA
VA

4.5
5.0 5.0
LL

4.9
4.6

DUCT BELOW LLE 6.5 6.7 6.7


E

4.0
2.8
Y

Y 3.0

7.9 5.8 3.5 7.9 6.5 4.7

5.8 5.1
DUCT BELOW 1.3 1.3 DUCT BELOW

ROAD 12 M WIDE
3.5 3.5 4.4

2.5 9.8

RIDGE
2.4
DUCT BELOW
2.5 DUCT BELOW 2.4
RIDGE
5.8 4.4

RIDGE
6.2

RIDGE
7.6

6.0 8.9 7.4

7.0 12.7

0.9 OHT 0.9 10.2 10.3

B 7 X 3.5 B 7.4 7.4 7.4 7.4


EY

VA
3.0 4.5

3.5 3.6 3.6 3.5


VA
LL

LL
3.0 3.0
VA

LLE

EY
900 MM DIA MANHOLE 900 MM DIA MANHOLE
Y

EY

RIDGE
RIDGE

LL
VA
2.8 2.8

BLOCK PLAN
1.8 1.3 9.2 2.9 4.7 9.2 1.3

PROFORMA B :

BASEMENT PLAN, BUA DIAGRAM & FSI CALCULATIONS

DESCRIPTION OF PROPOSAL OR PROPERTY:

LAND BEARING C.S.NO.(s) 489,490 BANDRA WEST


(AT PERRY ROAD, MUMBAI)

TERRACE PLAN SC:1:100


STAMP OF APPROVAL OF PLANS :

DRAWN BY : CHECKED BY :

VINAYAK BHARAT CHIPLUNKAR

SIR J.J.COLLEGE OF ARCHITECTURE

SEM VII SCALE:- 1:100 PLATE


NO :
ROLL : 1817 DATE: 09/11/20 3
NO
ROAD 12 M WIDE

0.7 8.3 1.9 15.4 4.9 8.3 0.6


CHAJJA BELOW 600 MM WIDE

1.5 1.5

RIDGE
VA
LLE
Y
ROAD 12 M WIDE
RIDGE

RIDGE
RIDGE

EY
3.2

LL
EY

VA
LL
VA

ROAD 12 M WIDE
3.0 3.0

VA
VA

4.5
5.0 5.0
LL

4.9
4.6

DUCT BELOW LLE 6.5 6.7 6.7


E

4.0
2.8
Y

Y 3.0

7.9 5.8 3.5 7.9 6.5 4.7

5.8 5.1
1.3 1.3
DUCT BELOW DUCT BELOW

ROAD 12 M WIDE
3.5 3.5 4.4

LOBBY LOBBY
2.4 DUCT BELOW DUCT BELOW 2.4 5.8 4.4

RIDGE 5.73 X 3.43 2.5 X 6.75 RIDGE RIDGE

SD1
6.2

RIDGE
7.6

1.2

10
1

9
4
8.9 7.4

12.7

RISER=150MM
UP

TRADE=300MM
1.5 10.2 10.3

B 0.3 B 7.4 7.4 7.4 7.4


EY

VA
3.0 4.5

FW1
3.1 3.1
3.5 S.L. P.L. 3.5
VA
LL

LL
1.5 3.0 3.0
VA

LLE

2.2

EY
2 X 2.2 1.9
2X2

DOWN
0.6
Y

EY

RIDGE
1.0
RIDGE

LL
2.0 2.0 1.5

19

18

17

16

15

14

13

12

11
20

VA
0.9
1.2
0.6

2.8 2.8

BLOCK PLAN
1.8 1.3 9.2 2.9 4.7 8.0 9.2 1.3

PROFORMA B :

BASEMENT PLAN, BUA DIAGRAM & FSI CALCULATIONS

DESCRIPTION OF PROPOSAL OR PROPERTY:

LAND BEARING C.S.NO.(s) 489,490 BANDRA WEST


(AT PERRY ROAD, MUMBAI)

TERRACE PLAN SC:1:100


STAMP OF APPROVAL OF PLANS :

DRAWN BY : CHECKED BY :

VINAYAK BHARAT CHIPLUNKAR

SIR J.J.COLLEGE OF ARCHITECTURE

SEM VII SCALE:- 1:100 PLATE


NO :
ROLL : 1817 DATE: 09/11/20 3
NO
ROAD 12 M WIDE

0.7 8.3 1.9 15.4 3.0 4.9 8.3 0.7

6.1 2.3 3.8 3.5 3.2 1.4 3.4 2.4 3.4 2.6
5.0 4.9
2.0 2.0 2.0 2.0
0.6

6.5
6.7 W1 W1
3.0 TOILET
1.2 3.2 6.7
3.5 3.3 W3 W1
W1

1.5 W2
DINING 2.1
M. BEDROOM
2.0 1.5 M. BEDROOM
D3 1.6 2.0
3.5 3.6 3.6 4.7
6.5
BEDROOM
2.2 3.4 2.1 2.1 3.4 2.2
W1 W2 W2 W1
1.5
0.6 1.3 W3 TOILET D3
5.3 M. BEDROOM D3
TOILET
W3 1.3 0.6
1.5
M. BEDROOM KITCHEN D2 1.3
D3
KITCHEN
5.8 1.5 2.0
1.4
0.0
2.8 3.6 3.7 3.7 3.6 2.8
W2
3.0 3.0
1.0 D2 D2 1.0
W4 D2 W4
TOILET 1.6 D3
W3 3.3
DINING 2.4 1.3 DINING
3.8 LIVING 3.0 BEDROOM 3.4 3.7
2.0 W1
BEDROOM W1
2.0
0.6 ROOM D3
M. BEDROOM
D2 3.2 2.0 1.9 D2

TOILET KITCHEN TOILET

ROAD 12 M WIDE
D2 D2
1.2 1.2 2.9 1.2 1.2
W3 W1 W3 3.5
D3 5.8 D3
D2 5.9 D2
2.8
7.9 0.6 2.0 0.6 7.9
2.2 5.8 3.5 2.2
1.2 1.2 TOILET 1.3 1.3 3.0
TOILET 1.2 1.2
W3 LIVING W3
3.0 ROOM 3.0
1.2
1.5 3.5 0.6 LIVING 0.6 3.5 1.5
D1
4.1 2.0 W1
3.8 ROOM 1.0 D2 D2 1.0 1.2
3.8 W1
2.0 4.1
M. BEDROOM TOILET
TOILET M. BEDROOM
2.4 W3 2.40.6 2.5 2.4 W3 2.4

SD1
D3 D2 1.0 1.2 D3
1.2 D1
0.6 0.6 0.6 0.6
1.2
7.6 LIVING 4.4
1.7 1.8 ROOM 1.8 1.7

10
3.2 3.2

9
2

4
W3 W3 W3 W3
LIVING 2.9

RISER=150MM
UP

TRADE=300MM
TOILET 1.9 TOILET 1.9 ROOM 1.5
1.9 TOILET 1.9 TOILET
7.6
B M. BEDROOM D3 0.3 D3
M. BEDROOM B

FW1
2.0 3.3 W1 3.1 3.1 W1 3.3 2.0
3.5 3.5
1.5
2.2

L.O.S.
23.0 1.9

DOWN
D3
7.3 0.6 7.3 D3
D2 1.2 1.0 1.2 D2 1.2
D2 3.5 2.0 1.5

20

19

18

17

16

15

14

13

12

11
1.2
0.9 6.2
1.2
1.8 0.6

BEDROOM KITCHEN DINING DINING KITCHEN


2.6 2.6 2.6 2.6
2.8 8.9 BEDROOM 2.8

2.3 2.3
W1 W1 W1 W1
3.1 3.0 3.0 3.1

2.0 1.4 2.0 2.0 1.4 2.0


13.7

12.7

4.2 FFT DOMESTIC 10.2


10.2
3.4 2.4 3.4 2.2

10.3
2.5 1.3 7.0 3.4 2.3 3.5

10.2

1.4 1.4 TANK 1.3

7.4
9.2

7.4
1.4 12.9 1.3

7.4
9.2 1.3

2.9
L.M.R. 2.6 3.6 15.0

3.0

24.0 2.2

GROUND LINE
1.4
GROUND LINE
KEY PLAN
2.8

GROUND LINE

2.8
ROAD 12 M WIDE
GROUND LINE
3.0 3.0
4.5
5.0 5.0
2.8
4.9
4.6
6.5 6.7 6.7 4.0

3.0
6.5 4.7

5.8 5.1

GROUND LINE

ROAD 12 M WIDE
4.4

2.8
5.8 4.4

6.2

GROUND LINE 7.6

8.9 7.4

12.7

2.8 10.2 10.3

7.4 7.4 7.4 7.4


3.0 4.5

3.0 3.0

GROUND LINE

2.8

GROUND LINE

2.8
BLOCK PLAN
GROUND LINE

2.8
PROFORMA B :
GROUND LINE
BASEMENT PLAN, BUA DIAGRAM & FSI CALCULATIONS
2.8

GROUND LINE

4.5

DESCRIPTION OF PROPOSAL OR PROPERTY:

GROUND LINE LAND BEARING C.S.NO.(s) 489,490 BANDRA WEST


(AT PERRY ROAD, MUMBAI)

STAMP OF APPROVAL OF PLANS :

SECTION BB' SC:1:100 DRAWN BY : CHECKED BY :

VINAYAK BHARAT CHIPLUNKAR

SIR J.J.COLLEGE OF ARCHITECTURE

SEM VII SCALE:- 1:100 PLATE


NO :
ROLL : 1817 DATE: 09/11/20 3
NO

You might also like