DIGITAL LOAD CELL INDICATOR WITH ALARM

DESCRIPTION
• Input : strain-gauge input from load cell
• Can be connected to up to 4 parallel load cells
without the Junction box
• Display with 7-Segment Red 5 digits, 0.56 inches
• High sensitivity (2 ms)
• Peak Hold and Tare zero can be recorded
TECHNICAL SPECIFICATION • 3 Alarm Relay Outputs with 4 Alarm Functions
• 4-20 mA and 0-10 VDC (Option) Transfer Output for
Power Supply 110 to 240 VAC +-10% 50/60 Hz other peripherals
Power Consumption 3VA • Can communicate with computer by using RS-485
7 Segment , Size 0.56 Inch , 5 Digit ,1 Row port. Modbus RTU Protocol
Display Display Range -19999 to 19999 • Automatic Calibration System for Strain Gauge which
Excitation Voltage 5VDC / 10 VDC ±5% ,
Load Max 120 mA
has 6 wires
• Lock function to prevent changing settings through
Strain-Gauge 1.5, 2, 2.5, 3, 3.3 mV/V the screen
A/D 24 Bits Delta-Sigma • 4 decimal places
Sampling Time 2 mSec. • Sensor Correction ± 999
Input Accuracy ± 1% of Full Scale • Digital input for operation
Sensor Correction ±999
Digital Input 1 Digital Input for Dry Contact OPERATION
Disable, Tare Zero, Reset Tare,
Display Tare, Reset Peak Memory, CM-013 is a digital display with alarm, displaying
Function Display Hold Function, Display Batch, the weight (Load cell) With a high speed of 2 ms, the
Add Batch, Clear Batch measurement accuracy is accurate to the moment,
3 Relay Output 5A/250VAC such as when measuring the weight in a silo tank. If
Output the display has a slow response The actual weight is
Hysteresis, High Limit, Low Limit
Transfer Output 0-10 VDC, 4-20mA (Option) greater than the display value. The silo tank is filled up
all the time. The Peak can also be displayed by pressing
Protocol MODBUS RTU the front button and resetting the Peak, Tare zero
Baud Rate 1200, 2400, 4800, 9600, 19200 bps value at the keypad or from the Digital Input at the
Parity None, Even, Odd rear terminal
Communication Stop Bits 1 The CM-013 can be connected to up to 4
Data Bits 8 parallel load cells without the Junction Box. The 4-wire
Maximum 32 and 6-wire load cell can also be connected. This will
Support Node allow the Autocal
Ambient Temperature -10 oC to 60 oC
Operation Humidity 85 % RH Non-Condensing APPLICATION
Ambient Temperature -20 oC to 80 oC • Weighing or weighing display machine
Storage Humidity 85 % RH Non-Condensing • Food industry
Front • Plastic industry
Protection Protection Rating IP52 • Rubber industry, polymer, rubber, fiber etc.
Degree Case
Protection Rating IP30
Installation Panel Mounting
Material ABS-V0
Size 48 x 96 x 80 mm.
Weight 300 g.
DIGITAL LOAD CELL INDICATOR WITH ALARM =

CM-013 3
AIR, FLOW TRANSMITTER DIGITAL LOAD CELL INDICATOR WITH ALARM

WIRING DIAGRAM

purchase order

To connect more than one load cell to each other in 4 lines.


6-wire Strain-gauge with CAL Usage must
Can connect up to 4 characters without Junction Box
be set equal 5 (Auto Calibrate)

DIMENSION

DISPLAY INDICATOR SERIAL COMMUNICATIONS


= TEMPERATURE SENSOR

4 CM-013
DIGITAL LOAD CELL INDICATOR WITH ALARM

ALARM OUTPUT
1. Process value High Low Band Alarm 3. Process value Low Alarm
Alarm Alarm
Output Output
SP-ALL SP+ALH SP-ALL
ON ON

OFF OFF
HYS HYS HYS
PV PV

2. Process value High Alarm 4. Process value High Low Range Alarm
Alarm Alarm
Output Output
SP+ALH SP-ALL SP+ALH
ON ON

OFF OFF
HYS HYS HYS
PV PV

LINEARIZATION ORDERING CODE


LINEARIZATION Set engineering units from the Strain Transfer Output Communication
gauge or Load cells. In case the signal is straight. Only two points
(the first point - the last point) can work. If the signal is not linear, CM-013
the following points can be set : 2, 4, 8,16, 32
Warning : Before setting up Must know the input signal
(mV) or standard load. And the value to show (engineering Transfer Output Communication
units) F Transfer Output 0-10VDC M RS-485
G Transfer Output 4-20mA
Engineer Value
*** Remark : Standard Free 1 Digital Input / 3 Alarm model
NO-01

mV Strain Gauge
NO-00
CAL.FT CAL.En
Graph showing the relationship between nO-00_nO-01 and
CAL_Ft-CAL_En When the number of ranges LIn_St
equal 0
Engineer Value
NO-03
NO-02
NO-01
mV จาก Strain Gauge
NO-00
CAL.FT CAL.En
Graph showing the relationship between nO-00_nO-02
and CAL_En When the number of ranges LIn_St equal
4 The graph will not be Linear, which will be used if the signal
from the Strain Gauge is not linear.
* The last point should be at 80% of Full Load