STAMP:

610-108 610-107 610-106 610-105


UNIT 3X C
UNIT 2X UNIT 1X B A
UNIT 3
1 2 3 4 5 6
A6B4-02 A6B4-01 A6B4-01
101'-6"
1"
21'-82 1"
9'-12
6'-7" 21'-11" 20'-0" 19'-11" 4" 11" 1'-0"
1"
4'-82 1
5'-32"
13'-9" 8'-2" 6'-7" 13'-5" 13'-5" 6'-6" 4'-6" 12'-6" 3'-10"

12 12 12
1-HR 1-HR 1-HR
AD0-04 AD0-03 AD0-04

2'-0"
BEDROOM 4
9'-6 1/2" CLG
CARPET

BEDROOM 3 BEDROOM 3
8'-10 1/2" CLG 8'-8" CLG
ENTRY ENTRY CARPET CARPET ENTRY
OPEN ABOVE OPEN ABOVE OPEN ABOVE
TILE TILE TILE

18'-10"

15'-2"
18 R 17 R 16 R
UP UP UP

HALL
9'-6 1/2" CLG
CARPET
BATH 3 BATH 3 BATH 3

BROOKFIELD
CAST IRON
K-5942-5
SINKS

DLNEO
IF
5RK
-2
IS
O
4TKO
9
SN
5A
R-IC
S
B
K

BROOKFIELD
CAST IRON
K-5942-5
SINKS
8'-10 1/2" CLG 8'-10 1/2" CLG 8'-8" CLG
TILE TILE TILE
CU. FT.

MAYFAIR

6"
STORAGE HALL HALL STORAGE 288
SLOPED CLG ENTRY 9'-6 1/2" CLG 9'-4" CLG SLOPED CLG
CARPET OPEN ABOVE CARPET CARPET CARPET

5'-0"
TILE

3'-4"
ENTRY

DYNAMETRIC
CAST IRON
K-519
BATH

CIR
NTOERMI A
9
T
H1N
S
T5Y
A-D
C
B
K

DYNAMETRIC
CAST IRON
K-519
BATH
A 8'-8" CLG A

LOTS 4 & 10
STORAGE

1"
TILE

3'-102

14'-2"
9'-4" CLG

PARKING SPACE
ACCESSIBLE VAN
TILE

8'-8" CLG

9'-2"
5'-6"
BUILDINGS 4-6

21'-10"

1"
25'-1"

17'-112

12'-8"

12'-8"
M.P.O.E
2-CAR 2-CAR 2-CAR 2-CAR 9'-4" CLG
CONCRETE
PARKING PARKING PARKING PARKING
9'-6 1/2" CLG 9'-6 1/2" CLG 9'-4" CLG 9'-4" CLG
CONCRETE CONCRETE CONCRETE CONCRETE

1'-0" 2'-3"

26'-6"
B B

7"
9 10 11 12 13 14 15 16

53'-6"

08-12-2020 - 2019 CODE UPDATE BUILDINGS 4-6


W4
BIKE OAKWOOD COMMUNITES, INC.
RACKS

98'-4"
AD0-01 TYP. 9'-4" CLG
CONCRETE

101'-3"

13'-10"
64 MAXWELL

13'-9"

13'-9"

13'-3"
1" 1" 1" 1" IRVINE, CA 92618

10'-6"
1'-0" 5'-62 21'-112 20'-0" 20'-0" 21'-112 5'-32 3'-10"
PHONE: (949) 719-9040
16
1-HR FAX: (949) 861-8696
AD1-01

21'-0"

3'-0"
4'-11"
D 1 HOUR RATED DUCT LADDER D
A6B4-02 CHASE ABOVE FOR CONCRETE A6B4-02
GARAGE EXHAUST

10'-6"
VENTILATION

13'-9"

13'-9"
PARKING SPACE NUMBERS. STORAGE
REFER TO 'GENERAL CLOSET

10'-8"
ASSIGNED SPACES AS DETERMINED BY NOTE' #3 THIS SHEET 9'-4" CLG

8'-9"
CONCRETE
THE HOA. 1"
2'-9" 5'-12

10" 3'-3"
1 2 3 4 5 6 7 8
C C
(4) 4" CONCRETE

30'-6"
4'-9"
FILLED METAL
BOLLARDS. SPACED
PER DIMENSIONS

4'-9"
BUILDING DEPARTMENT SUBMITTAL:

13'-10"
UTILITY

16'-10"
9'-4" CLG

1"

1"
17'-112

17'-112
CONCRETE
9th SUBMITTAL 09/05/2018

1"
2-CAR 2-CAR 2-CAR 2-CAR

17'-12
PARKING 12 PARKING PARKING 12 PARKING
1-HR 9'-6 1/2" CLG 1-HR CONCRETE 10th SUBMITTAL 09/25/2018

4'-9"
9'-6 1/2" CLG 9'-4" CLG 9'-4" CLG
CONCRETE AD0-04 CONCRETE CONCRETE AD0-04
TYP. @ STAIRS 11th SUBMITTAL 10/16/2018

26'-0"
12
1-HR VESTIBULE 12th SUBMITTAL 12/21/2018

3'-0"
AD0-03

4'-9"
9'-4" CLG
CONCRETE
13th SUBMITTAL 02/06/2019

1"
1'-12

1"
1'-12
D D REVISIONS:
8'-8" CLG

STORAGE

10'-0"
1"

1"
8'-10 1/2" CLG 8'-8" CLG
FIRE

8'-102

8'-102
9'-4" CLG
STOR. ENTRY TILE STOR. STOR. TILE TILE
ENTRY
RISER 9'-6 1/2" CLG 9'-6 1/2" CLG
9'-6 1/2" CLG 9'-4" CLG
8'-8" CLG
9'-6 1/2" CLG CARFPET CARPET CARPET
TILE TILE
CONCRETE
UP ENTRY ENTRY
17 R 9'-6 1/2" CLG 9'-4" CLG
8'-8" CLG
1
TILE TILE

6"
AD0-01 TYP.

2'-5" 6"
UP
16 R

10" 1'-7"

2'-11"
8'-10 1/2" CLG

2'-5"
4'-8" 12'-6" 4'-6" 5'-10" 14'-1" 14'-1" 5'-10" 4'-6" 12'-6" 4'-8"

6'-7" 21'-8" 4" 19'-11" 19'-11" 4" 21'-8"

101'-6" 10'-1" 1'-0"

C B A
1 2 3 4 5 5.1 6
A6B4-2 A6B4-01 A6B4-01
610-101 610-102 610-103 610-104
PROJECT DIRECTOR: EB, NC, JM
UNIT 3 UNIT 2 UNIT 2 UNIT 3
JOB CAPTAIN:
SENIOR ASSOCIATE: SA
ASSOCIATES: HK, MG, RK
PROJECT NUMBER: 15020
UNIT MATRIX - BUILDING 6 (610)
PROJECT CAD FILE: 15020_A6_B2-01
EAST WEST
*610-101 *610-102 *610-103 610-104 610-105 *610-106 *610-107 *610-108
SHEET TITLE:
UNIT # 3 2 2 3 3 1X 2X 3X
1ST FLOOR 3B-8 2A 2A 3B-7 3B-6 1XB 2XA 3XB
2ND FLOOR
3RD FLOOR
3A-3
3A-3 2A 2A
2A
3B 3B-6 1XB 2XA-1 3XA
2A 3B 3B-6 1XB 2XA 3XA BUILDING 6
'*' INDICATES UNITS REQUIRED TO HAVE ALL WINDOWS WITH AN STC
RATING OF 30 OR GREATER.
REFER TO WINDOW SCHEDULE SHEET AA5-01 FOR ADDITIONAL
INFORMATION
FIRST FLOOR PLAN
FIRST FLOOR PLAN BLDG 6
SCALE: 1/8" = 1'-0"

FLOOR PLAN NOTES GENERAL NOTES


SYMBOL LEGEND:
1-HOUR EXTERIOR WALL - REFER NON-RATED 2x6 EXTERIOR WALL 1. HORIZONTAL AND VERTICAL DIMENSIONS SHOWN 8. ALL ELECTRICAL FIXTURES, OUTLETS AND
AA W1 W2 W3
WALL TYPE TO SHEET AD0-01 FOR DETAILING FRAMING PER BUILDING PLANS - ARE FROM FACE OF STUD, FACE OF CONCRETE, EQUIPMENT ARE FOR REFERENCE ONLY REFER ROBERT HIDEY ARCHITECTS, INC. © 2020 - ALL RIGHTS
W9 REFER TO DETAIL W9 / AD0-01.2 RESERVED THE DRAWINGS, DESIGNS, INFORMATION,
OR FACE OF CMU, UNLESS NOTED OTHERWISE. TO ELECTRICAL DRAWINGS FOR DESIGN, DETAILS
XX 2x4 WALL FRAMING CONTENT AND PROCEDURES DESCRIBED HEREIN ARE
AND DIMENSIONS BY OTHERS.
KEY NOTE 1-HOUR 2X4 SHAFT ENCLOSURE - FOR THE EXCLUSIVE USE OF ROBERT HIDEY
A 2x6 WALL FRAMING 2. ANY DISCREPANCY FOUND IN THESE DRAWINGS
SEE INTERIOR ELEVATION SHEETS REFER TO DETAIL W17 / AD0-01 SHALL TO BE BROUGHT TO THE ATTENTION OF 9. ALL STRUCTURAL MEMBERS AND ELEMENTS ARE ARCHITECTS, INC., OR AFFILIATES, AND, AS SUCH, ARE
X FOR CORRESPONDING VIEWS W17 NOT TO BE REPRODUCED IN ANY FORM OR MEDIA,
D B THE ARCHITECT PRIOR TO ANY CONSTRUCTION. SHOWN FOR REFERENCE ONLY REFER TO
AA-XX CURRENT OR FUTURE, OR DISCLOSED TO OTHERS
1-HOUR DWELLING SEPARATION STRUCTURAL ENGINEERS DRAWINGS FOR DESIGN, WITHOUT THE WRITTEN CONSENT OF ROBERT HIDEY
C
W13 W14 W15 3. NOTHING EXCEPT THE GARAGE EXHAUST DUCT DETAILS AND DIMENSIONS.
WALL - REFER TO SHEET AD0-01 ARCHITECTS, INC. DISTRIBUTION OR DUPLICATION OF
= TEMPERED GLASS (TYP) FOR DETAILING CAN BE INSTALLED IN THE VERTICAL SHAFT FOR THESE DOCUMENTS IS NOT TO BE CONSTRUED AS
= EMERGENCY EGRESS WINDOW (TYP) THE GARAGE EXHAUST. 10.CONTRACTOR TO COORDINATE PLUMBING, PUBLICATION IN DEROGATION OF THESE RIGHTS.
= LOCATION OF INTERNATIONAL SYMBOL OF 2X4 WALL FRAMING ASSEMBLY MECHANICAL, ELECTRICAL PENETRATIONS AND VISUAL CONTACT WITH THESE DOCUMENTS SHALL
ACCESSIBILITY AT BUILDING ENTRANCE. SEE 4. NOT USED CONNECTIONS WITH SUBCONTRACTORS. CONSTITUTE EVIDENCE OF ACCEPTANCE OF THESE
DETAIL X/XXX RESTRICTIONS.
5. NOT USED. 11. ALL EQUIPMENT, APPLIANCES, AND FIXTURES TO
ACCESSIBLE/ADAPTABLE UNIT 2X6 WALL FRAMING ASSEMBLY BE INSTALLED PER MFR'S RECOMMENDATIONS. SHEET NUMBER:
6. ALL EXTERIOR PAVING AND SITE ELEMENTS ARE
FOR REFERENCE ONLY REFER TO LANDSCAPE 12. MASTER BEDROOM SHOWER WILL RECEIVE
LIGHT GAUGE METAL STUD WALL AND CIVIL DRAWINGS FOR DESIGN, DETAILS AND ENCLOSURE. THE SECONDARY BATHS WILL

A6B2-01
(USED AS A UTILITY WALL) DIMENSIONS. RECEIVE SHOWER ROD.
2x4 NON-RATED INTERIOR WALL 7. ALL MECHANICAL EQUIPMENT, GRILLS AND 13. FLOOR COVERING MATERIALS SHALL COMPLY
SEE DETAIL W9/ADO-01 CONTROLS ARE FOR REFERENCE ONLY REFER TO WITH ASTM E 648, AND A SMOKE DENSITY RATING
W9 2X4 WALL FRAMING ASSEMBLY
MECHANICAL DRAWINGS FOR DESIGN, DETAILS OF LESS THAN 450 PER ASTM E 84. (CBC 804.4.1)
AND DIMENSIONS BY OTHERS.
2x6 NON-RATED INTERIOR WALL
14. MINIMUM FOUR INCH (4") JAMB ON HINGE SIDE,
SEE DETAIL W9/AD0-01 2X6 WALL FRAMING ASSEMBLY PLOT REFERENCE DATE: 08/11/2020
UNLESS NOTED OTHERWISE.
W9