You are on page 1of 6
Reo, | CEPREUREC-DIFS}86-16110-16)A Total panes 6 TEST REPORT Product: DIGITAL PORTABLE RADIO ‘Type: PH500 U1 400-470MHz Test Category: Entrusted Test Manufacturer: ZTE TRUNKING TECHNOLOGY CORPORATION a ny Client: ZTE TRUNKING TECHNOLOGY CORPORATION CHINA CEPR ABORATORY (08) an rial Engroo EME Rell and Enviro esearch Centre POINTS FOR ATTENTION 41 The Test Repotis invalid without the seal ofthe testing organization. 2. The duplicated report is invalid without the seal of the testing organization. 3. The Test Repot is invalid without any signatures of the tester, the reviewer and the approver. 4 The Test Repor is invalid if being altered without the permission ofthe testing organization. '5 Any objections must be raised to the testing organization within 18 days after the report is received. It wll not be taken into consideration beyond tis limi 18 The Test Report is valid only forthe tested specimen. ‘Address: No.110,Dongguanzhuang Road, ante Distic,Guangzhou, ‘Guangdong Province, PR. China Post Address: P.0.Box 1501-36 Guangzhou, PR. China Post Code: 510510 ‘ol: +86-20-87206514, 87236391 Fax: +86-20-87237620 Chios CEPRE! Lory Rabi an rvkomenlEgrsing Research Cente cern REC 05,0616 10.0.8 age 3018 TEST REPORT Information of client Client: 2TE TRUNKING TECHNOLOGY CORPORATION ‘Address of cient: Sullding 2, ZTE Industrial Park, LiuXian Road, Xl, Nanshan District, Shenzhen, PR.China Specimen Product: DIGITAL PORTABLE RADIO ‘Type: PH500 U1 400-470MHz ‘Manufacturer. ZTE TRUNKING TECHNOLOGY CORPORATION Brand: ZTE ‘Sampling Method: Sent by cient Received Dato: 2016.04.20 ‘Quantity: 1Pcs | ‘Specimen Detail: Visual evaluation Is OK before test Ambient Condition Test Place: CEPRE! Temperature: 260-290 Relative Humidity: 63%6~71% Air Pressure: 101k?a~102kPa ‘Test Standard (6842082008 Degrees of protection provided by enclosures (IP Code}: Delailed technical requirement is offered by client Conclusions ‘The specimen of DIGITAL PORTABLE RADIO (ype PHE0O U1 400.470MHz) sent by ZTE TRUNKING TECHNOLOGY CORPORATION has experienced the IPXT and IPGX tess (test date 2016.04.22-2016.04.26). ‘Specimen At#: Aft the IPXT test, there was no water access the specimen: the specimen could be turned on and talk-back function worked normally. Ate the IPOX test, there was no obvious dust access the specimen; the specimen could be turned on and talk-hack function worked normally ‘The specimen passed the tests, Tested bv Sig] Reviewed by A wW io: 1, Report CEPREIREC--86-1610-() haben replant yn ropa China CEPREI Labor Rese Endomenl Engrg Resch Cente (CHPREIRECS}B6:1610-06A ‘Test Description 4. xr 414 Specimen Test ‘specimen: DIGITAL PORTABLE RADIO, type PHE00 U1 400-470MHz, 1Pes, specimen No, Ati 4.2 Instrument usec forthe purpose ofthis tost 1 Designation [__sw Dus Dale 201508065 | 2015.10.15 ~2016.10.14 test system 73 Test Standard (6842082008 Decrees of protection provided by enclosures (IP Code); Detailed technical requirement is offered by cent. 114 Test Condition IP Code: IP, completely immersing the specimen in water; ‘) Lowest point of specimen: 100mm below the surface of the water; ) Duration ofthe test: 30min 115 Test Criterion CCheck inside ofthe specimen after test. The specimen could be tured on, and talk-back function worked noemally. 116 Test Photos Fig.1 Specimen A‘ before test Fig.3 Specimen A1# after test Fig Inside check ator test photo 1 Chios CEMRE! Laboratory Relay anéEnvarmarl Egnoureg Reseach Cano cemmaumsc 019) 906 10416. Page S06 es Fig 5 Inside check after test photo 2 Fig Inside check ater test photo 3 117 Test result ‘Specimen At#: Alte the tas, there was no water access the specimen; the specimen ‘could be turned on and talk-back function worked nocaly 2. 1Pox 24° Specimen ‘Test spacimen: DIGITAL PORTABLE RADIO, type PHS0O Ut 400-470MHz, 1Pcs, specimen No. Att 2.2 Instrument used for the purpose ofthis test No. | Designation Tye SN Due Date: 1 Dust chamber | Sc-078 | o711166 | 2076.00.21 - 2016020 23. Test Standard (6842082008 Decrees of protection provided by enclosures (IP Code} Delailed technical requirement is offered by cient 24 Test Condition IP Code: IP6X;, ‘) Talcun powder amount 2kgin’s b) Test tine: 2h, 25 Test Chiterion Check inside ofthe specimen after test. The specimen could be turned on, and talkback function worked normally. 26 Test Photos Fig.7 Specimen At# before tost Fig & IPBX test setup photo Chins CEPRE! Laboratory Reiland Eniermertl Engng esearch Cee Fig.8 Specimen At# after test Fig-10 Specimen At# after test photo Fig. Inside chesk after test photo 1 27° Test result Specimen At#t Afr the test, there was no obvious dust access the specimen; the specimen could be tured on and tall-back function worked normally. Fig.12 Inside check aftr tos (China CEPREI Laboratory etait anneal Engen Reseach Ceoee

You might also like