TEST REPORT
Product: DIGITAL PORTABLE RADIO
‘Type: PH500 U1 400-470MHz
Test Category: Entrusted Test
Manufacturer: ZTE TRUNKING TECHNOLOGY CORPORATION
a
ny
Client: ZTE TRUNKING TECHNOLOGY CORPORATION
CHINA CEPR
ABORATORY
(08) an
rial Engroo
EME
Rell and Enviro esearch CentrePOINTS FOR ATTENTION
41 The Test Repotis invalid without the seal ofthe testing organization.
2. The duplicated report is invalid without the seal of the testing organization.
3. The Test Repot is invalid without any signatures of the tester, the reviewer
and the approver.
4 The Test Repor is invalid if being altered without the permission ofthe testing
organization.
'5 Any objections must be raised to the testing organization within 18 days after
the report is received. It wll not be taken into consideration beyond tis limi
18 The Test Report is valid only forthe tested specimen.
‘Address: No.110,Dongguanzhuang Road, ante Distic,Guangzhou,
‘Guangdong Province, PR. China
Post Address: P.0.Box 1501-36 Guangzhou, PR. China
Post Code: 510510
‘ol: +86-20-87206514, 87236391
Fax: +86-20-87237620
Chios CEPRE! Lory Rabi an rvkomenlEgrsing Research Centecern REC 05,0616 10.0.8 age 3018
TEST REPORT
Information of client
Client: 2TE TRUNKING TECHNOLOGY CORPORATION
‘Address of cient: Sullding 2, ZTE Industrial Park, LiuXian Road, Xl, Nanshan
District, Shenzhen, PR.China
Specimen
Product: DIGITAL PORTABLE RADIO
‘Type: PH500 U1 400-470MHz
‘Manufacturer. ZTE TRUNKING TECHNOLOGY CORPORATION
Brand: ZTE
‘Sampling Method: Sent by cient
Received Dato: 2016.04.20
‘Quantity: 1Pcs |
‘Specimen Detail: Visual evaluation Is OK before test
Ambient Condition
Test Place: CEPRE!
Temperature: 260-290 Relative Humidity: 63%6~71%
Air Pressure: 101k?a~102kPa
‘Test Standard
(6842082008 Degrees of protection provided by enclosures (IP Code}:
Delailed technical requirement is offered by client
Conclusions
‘The specimen of DIGITAL PORTABLE RADIO (ype PHE0O U1 400.470MHz)
sent by ZTE TRUNKING TECHNOLOGY CORPORATION has experienced the
IPXT and IPGX tess (test date 2016.04.22-2016.04.26).
‘Specimen At#: Aft the IPXT test, there was no water access the specimen: the
specimen could be turned on and talk-back function worked normally. Ate the
IPOX test, there was no obvious dust access the specimen; the specimen could
be turned on and talk-hack function worked normally
‘The specimen passed the tests,
Tested bv Sig] Reviewed by A wW
io: 1, Report CEPREIREC--86-1610-() haben replant yn ropa
China CEPREI Labor Rese Endomenl Engrg Resch Cente(CHPREIRECS}B6:1610-06A
‘Test Description
4. xr
414 Specimen
Test
‘specimen: DIGITAL PORTABLE RADIO, type PHE00 U1 400-470MHz, 1Pes,
specimen No, Ati
4.2 Instrument usec forthe purpose ofthis tost
1
Designation
[__sw Dus Dale
201508065 | 2015.10.15 ~2016.10.14
test system
73 Test Standard
(6842082008 Decrees of protection provided by enclosures (IP Code);
Detailed technical requirement is offered by cent.
114 Test Condition
IP Code: IP, completely immersing the specimen in water;
‘) Lowest point of specimen: 100mm below the surface of the water;
) Duration ofthe test: 30min
115 Test Criterion
CCheck inside ofthe specimen after test. The specimen could be tured on, and talk-back
function worked noemally.
116 Test Photos
Fig.1 Specimen A‘ before test
Fig.3 Specimen A1# after test Fig Inside check ator test photo 1
Chios CEMRE! Laboratory Relay anéEnvarmarl Egnoureg Reseach Canocemmaumsc 019) 906 10416. Page S06
es
Fig 5 Inside check after test photo 2 Fig Inside check ater test photo 3
117 Test result
‘Specimen At#: Alte the tas, there was no water access the specimen; the specimen
‘could be turned on and talk-back function worked nocaly
2. 1Pox
24° Specimen
‘Test spacimen: DIGITAL PORTABLE RADIO, type PHS0O Ut 400-470MHz, 1Pcs,
specimen No. Att
2.2 Instrument used for the purpose ofthis test
No. | Designation Tye SN Due Date:
1 Dust chamber | Sc-078 | o711166 | 2076.00.21 - 2016020
23. Test Standard
(6842082008 Decrees of protection provided by enclosures (IP Code}
Delailed technical requirement is offered by cient
24 Test Condition
IP Code: IP6X;,
‘) Talcun powder amount 2kgin’s
b) Test tine: 2h,
25 Test Chiterion
Check inside ofthe specimen after test. The specimen could be turned on, and talkback
function worked normally.
26 Test Photos
Fig.7 Specimen At# before tost Fig & IPBX test setup photo
Chins CEPRE! Laboratory Reiland Eniermertl Engng esearch CeeFig.8 Specimen At# after test Fig-10 Specimen At# after test photo
Fig. Inside chesk after test photo 1
27° Test result
Specimen At#t Afr the test, there was no obvious dust access the specimen; the
specimen could be tured on and tall-back function worked normally.
Fig.12 Inside check aftr tos