Professional Documents
Culture Documents
Solar Heating Design
Solar Heating Design
No Records Units
1 3.8
2 4
3 5.5
4 6
5 6.9
6 6.5
7 5.7 kWhr/m^2
8 5.7
9 5.8
10 5.4
11 4.7
12 4
Average 5.333
Avg Mustang Sun Hours 5.333 kWhr/m^2 per day Calculated Value
Lowest Mustang Sun Hours 3.8 kWhr/m^2 per day Linked Value
Input
1. Heat Pump System
745
2740
Total Watt 2490
Total Whr 2740
PSH of Mustang 5.333
Solar PV
PV Capacity 513.75
FOS 20%
616.5
Panel Size 330
No of PV 1.868
Recommended PV nos 3
Series 3
Parallel 0
Battery
Efficieny 80%
DOD 80%
Battery Voltage 12
Days of Autonomy 2
Battery Capacity 178.385416666667
Battery Size 100
No of Batteries 1.78385416666667
Recommended Battery nos 4
Series 4
Parallel 1
Operating Voltage of PV 24
Battery Capacity 356.770833333333
No of Batteries 3.56770833333333
Recommended Battery nos 4
Series 2
Parallel 2
Inverter
FOS 20%
Inverter capacity 2988
Recommended Inverter Size 3.5
Operating Voltage 48
W
Whr
kWhr/m^2 per day
Wp
Wp
Wp
nos
nos 3 PV
nos to make 48V system(Inverter Based)
nos
V
days
Ah
Ah
nos
nos 4 Battery
nos to make 48V system(Inverter Based)
nos
V
Ah
nos to make 24V system (solar operating
voltage based)
1 Invertor
VA
kVA
V
Using Solar Thermal & Grid powered Heat Pump
7 Plumbing 60,000.00
8 Water Reserve 1000L *5 5 15,000.00 75,000.00
9 Installation Charge 50,000.00
7 Plumbing 60,000.00
8 Water Reserve 1000L *5 5 15,000.00 75,000.00
9 Instalation Charge 50,000
G.Total (C ) 780,000.00
Solar Pump
Invertor MPPT;
Solar Water Lifting System for 10m DC brushless
1 Head pumps & 3 Panels 600,000.00
G.Total (D ) 600,000.00
S.no System Cost