Professional Documents
Culture Documents
Omega Air Catalogue 2011
Omega Air Catalogue 2011
Compressed air
treatment
The missing piece of
Your business !
Telephone: +386 1 200 68 60 Telephone: +386 1 200 68 61 Telephone: +386 1 200 68 13 Telephone: +386 1 200 68 62
Mobile: +386 30 362 140 Fax: +386 1 200 68 53 Mobile: +386 30 362 190 Mobile: +386 30 362 180
Fax: +386 1 200 68 53 E-mail: spela.remic@omega-air.si Fax: +386 1 200 68 53 Fax: +386 1 200 68 53
E-mail: erik.krusec@omega-air.si E-mail: luka.trsar@omega-air.si E-mail: tilen.lovrecic@omega-air.si
2
Dear customers,
Certificates
The air is everywhere.
It is the essential part of our life.
Like the people, who needs high quality air for our breathing,
technology processes, pharmacy, industry,... needs it to.
We became experts in this range of air technology. Continually investing ISO 9001:2008
to new technologies, research & development, and quality processes can
give only great results. ISO and ASME certificates are only one proof.
Our numerous satisfied customers are the others.
CE-PED-H
CE-PED-H1
Our goals remains the same;
delivering top quality products to our customers.
www.omega-air.si 3
FILTERS FOR INDUSTRIAL APPLICATIONS
MDA 60
B P R
M
S
A
H2
A2
ECD-B
4
CARBON STEEL INDUSTRIAL FILTERS CAST ALUMINIUM HIGH PRESSURE FILTERS
page 10 BF series 16 bar page 32 HF series 50 bar
www.omega-air.si 5
FILTERS FOR STERILE AND PROCESS FILTERS FOR SPECIAL APPLICATIONS
APPLICATIONS
VACUUM PUMP PROTECTION FILTERS
6
CONDENSATE DRAINS CONDENSATE SEPARATORS
WATER-OIL SEPARATORS
MECHANICAL AUTOMATIC CONDENSATE DRAINS
page 27 AOK 20B series 20 bar WATER-OIL SEPARATORS FOR COMPRESSED AIR
page 29 WOS-M series
www.omega-air.si 7
industrial applications
Compressed air filters AF Series are used for efficient removal of solid
particles, water, oil vapours, taste and odours from compressed air in
industrial applications.
The type and size of filters depends of compressed air flow, type and quantity
of polution.
OPTIONAL EQUIPMENT
MCD AOK 16B AOK 20B TD16m TD16S ECD-B EMD12 60 ÷ 2.760 m3/h
CORRECTION FACTORS
Operating pressure [bar] 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Operating pressure [psi] 29 44 58 72 87 100 115 130 145 160 174 189 203 218 232
Correction factor 0,38 0,50 0,63 0,75 0,88 1 1,13 1,25 1,38 1,50 1,63 1,75 1,88 2,00 2,13
8
AF filter cartridges
Omega Air filter cartridge production includes 8 filtration stages (B,
P, R, M, S and A), which are designed to remove particulates, water,
oil vapours, taste and odours from compressed air. Two stage filter
elements are developed: A2 for high efficient removal of oil vapours
and odours and H2 for high efficint removal of carbon monoxide from
compressed air.
The design of filter media ensures the effective and efficient removal ed
ent
most of contaminates in compressed air systems. For CO and CO2 pat
removal please contact us.
ed
ent
Materials are corrosion-proof and suitable for most of applications. pat
The filter and cartridge size is determined by the compressed air flow.
They are all designed for operation pressure up to 16 bar (232 psi).
Flow rate
Cartridge at 7 bar(g), 20°C Max. oper.
Filter’s B P R M S A A2 H2
pressure sintered prefilter prefilter microfilter microfilter active adsorption catalyst
size housing
m3/h SCFM [bar/psi] 15 μm 3 μm 1 μm 0,1 μm 0,01 μm carbon (act. carb.) (hopcalite)
06050 60 35 16/232 AF 0056 06050 B15 06050 P 06050 R 06050 M 06050 S 06050 A - -
07050 78 46 16/232 AF 0076 07050 B15 07050 P 07050 R 07050 M 07050 S 07050 A 07050 A2 07050 H2
14050 120 70 16/232 AF 0106 14050 B15 14050 P 14050 R 14050 M 14050 S 14050 A 14050 A2 14050 H2
2
12075 198 116 16/232 AF 0186 12075 B15 12075 P 12075 R 12075 M 12075 S 12075 A 12075 A 12075 H2
22075 335 197 16/232 AF 0306 22075 B15 22075 P 22075 R 22075 M 22075 S 22075 A 22075 A2 22075 H2
2
32075 510 300 16/232 AF 0476 32075 B15 32075 P 32075 R 32075 M 32075 S 32075 A 32075 A 32075 H2
2
50075 780 459 16/232 AF 0706 50075 B15 50075 P 50075 R 50075 M 50075 S 50075 A 50075 A 50075 H2
51090 1000 588 16/232 AF 0946 51090 B15 51090 P 51090 R 51090 M 51090 S 51090 A - -
76090 1500 882 16/232 AF 1506 76090 B15 76090 P 76090 R 76090 M 76090 S 76090 A - -
76090 1680 990 16/232 AF 1756 76090 B15 76090 P 76090 R 76090 M 76090 S 76090 A - -
51140 2160 1270 16/232 AF 2006 51140 B15 51140 P 51140 R 51140 M 51140 S 51140 A - -
75140 2760 1620 16/232 AF 2406 75140 B15 75140 P 75140 R 75140 M 75140 S 75140 A - -
2
B P R M S A A H2
solid particle size purification: down to 15 microns 3 microns 1 micron 0,1 micron 0,01 micron - 0,1 0,1
pressure drop - new element [mbar / psi] 30 / 0,43 40 / 0,58 <50 / 0,72 <80 / 1,16 120 / 1,74 <90 / 1,3 see spec. see spec.
change filter cartridge at pressure drop [mbar / psi] 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 * 6 months * 6 months 6 months
activated hopcalite,
sintered active carbon,
filter material brass acrile fibres, celulose borosilicate micro fibres borosilicate borosilicate
carbon micro fibres
micro fibres
pleated version - + + + + - + +
wrapped version - + + + + + - -
sintered version + - - - - - - -
min. operating temperature (°C / °F) 1,5 / 35 1,5 / 35 1,5 / 35 1,5 / 35 1,5 / 35 1,5 / 35 1,5 / 35 1,5 / 35
max. operating temperature (°C / °F) 65 / 149 65 / 149 65 / 149 65 / 149 65 / 149 45 / 113 45 / 113 45 / 113
2 2
* Filter elements ’’A, A , H ’’ must be changed periodically to suit application but at least every 6 months. Activated carbon filters must not operate in oil
saturated conditions.
www.omega-air.si 9
industrial applications
B
øD
E
SIZES: SIZES:
BF 0240 BF 1200
16 bar
BF 0300 BF 1500
A
øD
BF 0450 BF 1800 1,5 ÷ 65 °C
A
BF 0600 BF 2500
C min
BF 0900 BF 3000
2.200 ÷ 31.400 Nm3/h
min.200 mm
min.650 mm
CORRECTION FACTORS
Operating pressure [bar] 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Operating pressure [psi] 29 44 58 72 87 100 115 130 145 160 174 189 203 218 232
Correction factor 0,53 0,65 0,76 0,84 0,92 1,00 1,07 1,13 1,19 1,25 1,31 1,36 1,41 1,46 1,51
10
BF filter cartridges
Omega Air filter cartridge production includes 6 filtration stages (B, P,
R, M, S and A), which are designed to remove particulates, water, oil
vapours, taste and odours from compressed air.
The design of filter media ensures the effective and efficient removal
most of contaminates in compressed air systems. Note that these filters
will not remove carbon monoxide or carbon dioxide.
All materials are suitable for operation in the temperature range from
1,5 to 65 °C (35 to 149 °F). They are corrosion-proof and suitable for
most of applications.
The filter and cartridge size is determined by the compressed air flow.
They are all designed for operation pressure up to 16 bar (232 psi).
B P R M S A
solid particle size purification: down to 15 microns 3 microns 1 micron 0,1 micron 0,01 micron -
pressure drop - new element [mbar / psi] 30 / 0,43 40 / 0,58 <50 / 0,72 <80 / 1,16 120 / 1,74 <90 / 1,3
change filter cartridge at pressure drop [mbar / psi] 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 *every 6 months
filter material sintered brass acrile fibres, celulose borosilicate micro fibres active carbon
pleated version - + + + + -
wrapped version - + + + + +
sintered version + - - - - -
* Filter elements ’’A’’ must be changed periodically to suit application but at least every 6 months. Activated carbon filters must not operate in oil
saturated conditions.
www.omega-air.si 11
industrial applications
Compressed air filters CF Series are used for efficient removal of solid
particles, water, oil vapours, taste and odours from compressed air in
industrial applications.
The type and size of filters depends of compressed air flow, type and
quantity of polution.
20 bar
1,5 ÷ 65 °C
72 ÷ 2.760 m3/h
B
Flow rate Operating
Dimensions [mm]
at 7 bar(g), 20°C Mass
Filter model Connection pressure
[kg]
Nm3/h scfm A B C D [bar]
80
CORRECTION FACTORS
Operating pressure [bar] 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Operating pressure [psi] 29 44 58 72 87 100 115 130 145 160 174 189 203 218 232 247 261 276 290
Correction factor 0,38 0,5 0,63 0,75 0,88 1 1,13 1,25 1,38 1,50 1,63 1,75 1,88 2,00 2,13 2,25 2,38 2,50 2,63
12
CF filter cartridges
CF Filter cartridge range includes 6 filtration stages (B, P, R, M, S and A),
which are designed to remove particulates, water, oil vapours, taste and
odours from compressed air.
The design of CF Filter media ensures the effective and efficient removal
most of contaminates from compressed air systems. Note that these
filters will not remove carbon monoxide or carbon dioxide.
All materials are suitable for operation in the temperature range from
1,5 to 65 °C (35 to 149 °F). They are corrosion-proof and suitable for
most of applications.
The filter and cartridge size is determined by the compressed air flow.
They are all designed for operation pressure up to 20 bar (290 psi).
CF 20 72 42 20/290 65/149 ** 20 CB 20 CP 20 CR 20 CM 20 CS 20 CA
CF 21 96 56 20/290 65/149 ** 21 CB 21 CP 21 CR 21 CM 21 CS 21 CA
CF 30 150 88 20/290 65/149 ** 30 CB 30 CP 30 CR 30 CM 30 CS 30 CA
CF 31 216 127 20/290 65/149 ** 31 CB 31 CP 31 CR 31 CM 31 CS 31 CA
CF 40 282 166 20/290 65/149 ** 40 CB 40 CP 40 CR 40 CM 40 CS 40 CA
CF 41 360 212 20/290 65/149 ** 41 CB 41 CP 41 CR 41 CM 41 CS 41 CA
CF 42 432 254 20/290 65/149 ** 42 CB 42 CP 42 CR 42 CM 42 CS 42 CA
CF 43 510 300 20/290 65/149 ** 43 CB 43 CP 43 CR 43 CM 43 CS 43 CA
CF 44 750 441 20/290 65/149 ** 44 CB 44 CP 44 CR 44 CM 44 CS 44 CA
CF 50 888 522 20/290 65/149 ** 50 CB 50 CP 50 CR 50 CM 50 CS 50 CA
CF 51 1176 692 20/290 65/149 ** 51 CB 51 CP 51 CR 51 CM 51 CS 51 CA
CF 52 1440 847 20/290 65/149 ** 52 CB 52 CP 52 CR 52 CM 52 CS 52 CA
CF 60 1968 1158 20/290 65/149 ** 60 CB 60 CP 60 CR 60 CM 60 CS 60 CA
CF 61 2760 1624 20/290 65/149 ** 61 CB 61 CP 61 CR 61 CM 61 CS 61 CA
B P R M S A
solid particle size purification: down to 15 microns 3 microns 1 micron 0,1 micron 0,01 micron -
quality class - solids (ISO 8573-1) 4 3 2 1 1 -
residual oil content [mg/m3 / ppm] - - - 0,1 / 0,08 0,01 / 0,01 0,005 / 0,005
quality class - oils (ISO 8573-1) - - - 2 1 1
pressure drop - new element [mbar / psi] 30 / 0,43 40 / 0,58 <50 / 0,72 <80 / 1,16 <90 / 1,3 120 / 1,74
change filter cartridge at pressure drop [mbar / psi] 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 *every 6 months
filter material sintered brass acrile fibres, celulose borosilicate micro fibres active carbon
pleated version - + + + + -
wrapped version - + + + + +
sintered version + - - - - -
* Filter elements ’’A’’ must be changed periodically to suit application but at least every 6 months. Activated carbon filters must not operate in
oil saturated conditions.
DF filter housings sre designed for high efficient removal of solid particles,
water, oil aerosols, hydrocarbons and odour vapours from compressed air
systems.
To meet the required compressed air quality appropriate filter element (B, P,
R, M, S, A) must be installed into filter housing.
OPTIONAL EQUIPMENT
16 bar
MCD AOK 16B AOK 20B TD16m TD16S ECD-B EMD12 1,5 ÷ 65 °C
60 ÷ 2.760 m3/h
Flow rate
Dimensions [mm]
at 7 bar(g), 20°C Mass B
Filter model Connection
[kg]
Nm3/h scfm A B C D
C
CORRECTION FACTORS
Operating pressure [bar] 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Operating pressure [psi] 29 44 58 72 87 100 115 130 145 160 174 189 203 218 232
Correction factor 0,38 0,5 0,63 0,75 0,88 1 1,13 1,25 1,38 1,50 1,63 1,75 1,88 2,00 2,13
14
DF filter cartridges
Omega Air filter cartridge production includes 6 filtration stages (B,
P, R, M, S and A), which are designed to remove particulates, water,
oil vapours, taste and odours from compressed air. Two stage filter
elements are developed: A2 for high efficient removal of oil vapours
and odours and H2 for high efficint removal of carbon monoxide from
compressed air.
The design of filter media ensures the effective and efficient removal
most of contaminates in compressed air systems. Note that these filters
will not remove carbon monoxide or carbon dioxide.
The filter and cartridge size is determined by the compressed air flow.
They are all designed for operation pressure up to 16 bar (232 psi).
wrapped version - + + + + + - -
sintered version + - - - - - - -
min. operating temperature (°C / °F) 1,5 / 35 1,5 / 35 1,5 / 35 1,5 / 35 1,5 / 35 1,5 / 35 1,5 / 35 1,5 / 35
max. operating temperature (°C / °F) 65 / 149 65 / 149 65 / 149 65 / 149 65 / 149 45 / 113 45 / 113 45 / 113
* Filter elements ’’A’’ must be changed periodically to suit application but at least every 6 months. Activated carbon filters must not operate in oil
saturated conditions.
www.omega-air.si 15
equipment for industrial applications
Technical data
Technical data
Technical data
16
AK - Assembly kit for filters
It is used for assembling of two, three or more
filters together.
Universal usage
Construction of assenbly kit is universal and
it can be used for any filter types, including
filters of other world producers.
www.omega-air.si 17
industrial applications
16 bar
1,5 ÷ 65 °C
120 ÷ 2.850 m3/h
MCD
AOK 16B
AOK 20B TD16S
ECD-B EMD12
TD16m
Model size
3
inch Nm /h SCFM A B C D A B C D kg lb
CKL 005 B 3/8 120 70 187 88 21 60 7 3/8 3 1/2 13
/16 2 5/16 0,7 1,54
CKL 007 B 1/2 155 91 187 88 21 60 7 3/8 3 1/2 13
/16 2 5/16 0,7 1,54
A
1 1 13
CKL 010 B 3/4 235 138 257 88 21 80 10 /8 3 /2 /16 3 1 /8 0,8 1,76
CKL 018 B 1 365 215 262 125 33 100 10 5/16 4 15/16 1 5/16 3 15/16 1,9 4,19
CKL 047 B 1 1/2 770 452 452 125 33 140 17 13/16 4 15/16 1 5/16 5 1 /2 2,8 6,17
CKL 094 B 2 1280 753 695 163 43 520 27 3/8 6 7/16 1 11/16 20 1/2 5,3 11,7
CKL 150 B 2 1/2 2460 1447 695 163 43 520 27 3/8 6 7/16 1 11/16 20 1/2 9,2 20,3 R 1/2’’
D
CKL 200 B 3 2850 1677 795 240 59 630 31 5/16 9 1/2 2 5/16 24 3/4 13,4 29,5
CORRECTION FACTORS
Operating pressure [bar] 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Operating pressure [psi] 29 44 58 72 87 100 115 130 145 160 174 189 203 218 232
Correction factor 0,53 0,65 0,76 0,84 0,92 1,00 1,07 1,13 1,19 1,25 1,31 1,36 1,41 1,46 1,51
18
Benefits
Construction of aluminium cyclone separators assures high efficiency condensate separation with low pressure drop.
Cartridge inside Cyclone separator assures reliable operation for the life of the separator, with no possibility of clogging and
increased operating costs.
Condensate Cyclone separator CKL-B satisfies all needs of applications in a wide temperature range from 1,5 to 65 °C (35 to
149 °F) and in a pressure range up to 16 bar (232 psi).
All alluminium separator bodies are coated with powder paint to eliminate corrosion.
Threaded connections are BSP according to ISO7/1 or NPT to ANSI B2.1, if supplied in North America.
air
condensate
(oil, water)
www.omega-air.si 19
industrial applications
16 bar
1,5 ÷ 120 °C
H
F
min 200 mm
CS 21 DN80 21 740 745 182 88,9 88,9 1/2’’ 159,0 302 35 29 5/16 7 3/16 3 1/2 3 1 /2 1
/2 6 1 /4 11 7/8 1 3/8 23 50,7
5 3 1 1 1 1 7 3
CS 28 DN80 28,5 1000 745 182 88,9 88,9 1/2’’ 159,0 302 35 29 /16 7 /16 3 /2 3 /2 /2 6 /4 11 /8 1 /8 23 50,7
1 1 1 5 3 11
CS 62 DN125 62,0 2190 1041 280 133,0 133,0 1/2’’ 219,1 390 43 41 11 5 /4 5 /4 /2 8 /8 15 /8 1 /16 53 116,8
20
process applications
16 bar
G
E 1,5 ÷ 120 °C
840 ÷ 2.196 Nm3/h
D
G
A
F
H
B
C
E
A
F
min 200 mm
Flow rate
at 7 bar(g), Dimensions [mm] Mass
Model Connection
20°C [kg]
[Nm3/min] A B C D E F G H
E
CS SS 14 DN80 14 745 182 88,9 88,9 1/2’’ 159,0 302 35 23
www.omega-air.si 21
condensate treatment
0 ÷ 16 bar
1,5 ÷ 65 °C
see table >>
Benefits
- robust aluminium housing
- integrated filter mesh
- compact design
- two-way connections
- eloxated housing
- contactless measuring
- direct acting, self cleaning valve (patented)
- blocked plunger release procedure
- operating diagnostic monitoring
- warning LED light for ’’drain operating’’ and ’’alarm’’
- AC versions (for DC version please contact Omega Air)
- IP 54 electrical protection
ed
ent
pat
22
Type ECD 15B ECD 40B ECD 90B ECD 150B
* Higher motor power capacities available on request. Please contact Omega Air.
Please take the relevant climate zone into account when dimensioning yours specific ECD-B drain series application:
Northern Europe, Canada, Northern USA, Central Asia
Central and Southern Europe, Central America
South East Asian coastal regions, Oceania, Amazon and Congo regions
www.omega-air.si 23
condensate treatment
Condensate flow constantly flushes debris out of the valve. Thats why
uninterrupted operating is guaranteed.
Type EMD12
Please take the relevant climate zone into account when dimensioning yours specific EMD 12 drain series application:
Northern Europe, Canada, Northern USA, Central Asia
Central and Southern Europe, Central America
South East Asian coastal regions, Oceania, Amazon and Congo regions
24
condensate treatment
Benefits
- easy opening time settings
- easy opening frequency settings
- no moving parts
- reliable operating without clogging and unsensible to
outside conditions
- test button
- warning LED light for condense disposal phase
0 ÷ 16 bar
1,5 ÷ 65 °C
0,2 ÷ 114 l/h
Technical data
- min/max operating temperature: 1,5 to 65 °C (35 to 149 °F)
- min/max operating pressure: 0-16 bar / 0-232 psi
- Input connection: R 1/2”
- output connection: R 1/8”
- output pipe diameter: 6-8 mm
- capacity at 10 bar (145 psi): 0,2 - 114 l/h
- mass: 0,35 kg
www.omega-air.si 25
condensate treatment
Benefits
- easy opening time settings
- easy opening frequency settings
- no moving parts
- reliable operating without clogging and unsensible to
outside conditions
- test button
- warning LED light for condense disposal phase
0 ÷ 16 bar
1,5 ÷ 65 °C
0,2 ÷ 114 l/h
Technical data
- min/max operating temperature: 1,5 to 65 °C (35 to 149 °F)
- min/max operating pressure: 0-16 bar / 0-232 psi
- Input connection: R 1/2”
- output connection: R 1/8”
- output pipe diameter: 6-8 mm
- capacity at 10 bar (145 psi): 0,2 - 114 l/h
- mass: 0,35 kg
C
Protection Cable Dimensions
Model Voltage Frequency El. power
class dimension A B C
TD16S 115 VAC 115 V +/- 10% 50-60 Hz 18 W IP54 3 x 0,75 mm2 3 7/16 inch 3 1/2 inch 4 7/8 inch
TD16S 230 VAC 230 V +/- 10% 50-60 Hz 18 W IP54 3 x 0,75 mm2
B
26
condensate treatment
Technical data
- material: aluminium alloy
- operating temperature range: 1,5 to 65 °C (35 to 149 °F)
- operating pressure range: 0 - 20 bar (0 - 290 psi)
- connection: R 1/2’’
- oil resistant o-ring
0 ÷ 20 bar
1,5 ÷ 65 °C
up to 300 l/h
1/2’’
107
130
132
1/2’’
www.omega-air.si 27
condensate treatment
Technical data
- material: brass
- operating temperature range: 1,5 to 65 °C (35 to 149 °F)
- operating pressure range: 0-16 bar (0-232 psi)
- connection: R 1/2’’
- oil resistant o-ring
Technical data
- material: durable plastic, brass
- operating temperature range: 1,5 to 65 °C (35 to 149 °F)
- operating pressure range: 0-16 bar (0-232 psi)
- connection: R 1/2’’
- oil resistant o-ring
28
condensate treatment
water-oil separator
Benefits
• no complex sizing required,
• floor or wall installation,
• works with any type od condensate drain,
• can handle and separate any type of oil,
• oil residue value is less than 20 ppm,
• easy to maintain,
• disposable filter cartridge,
• quick and clean filter cartridge changing,
• quick cooupling connection,
• no condensate settling tank is required (therefore
there is no bacteria build-up), AIR OUTLET
• small compact design,
1,5 ÷ 45 °C
DEPRESSURIZE CHAMBER
WITH AIR FILTER
1, 2, 4 m3/min
ed
ent
INLET pat
» condensate (oil, water)
» air
Separator model
WOS-M1 WOS-M2 WOS-M4 Disposable
filter cartridge
Max. capacity of compressed air [m3/h] / [m3/min] 60 / 1 120 / 2 180 / 3
Max. oil adsorbtion [Ltr]
29
condensate treatment
Benefits
• no complex sizing required,
• simple to install,
• works with any type od condensate drain,
• can handle and separate any type of oil,
• oil residue value is less than 10 ppm,
• easy to maintain,
• no condensate settling tank is required (therefore there is no
bacteria build-up),
• small compact design, 1,5 ÷ 45 °C
• test valve and test set included for sampling purposes.
4, 8, 20, 35 m3/min
30
INLET
» condensate (oil, water)
» air AIR OUTLET
DEPRESSURIZE CHAMBER
nd
2 stage chamber WITH AIR FILTER
CLEAN WATER
OUTLET
residual oil content
<10ppm » condensate
(oil, water)
Separator model
WOS-4 WOS-8 WOS-20 WOS-35
Max. capacity of compressed air [m3/h] / [m3/min] 240 / 4 480 / 8 1200 / 20 2100 / 35
Max. oil adsorbtion [Ltr] 3 10 15 25
C
www.omega-air.si 31
industrial applications
50 bar
1,5 ÷ 65 °C
450 ÷ 5.100 Nm3/h
HF 007 1/2 71 418 250 110 30 9 7/8 4 5/16 1 3/16 2,1 4,63 HF 6060
D
HF 010 3/4 112 659 250 110 30 9 7/8 4 5/16 1 3/16 2,1 4,63 HF 7060
HF 018 1 204 765 250 110 30 9 7/8 4 5/16 1 3/16 2,1 4,63 HF 12060
HF 047 1 1/2 282 1059 535 160 45 21 1/16 6 5/16 1 3 /4 9,5 20,9 HF 22090
1 5
HF 070 1 1/2 400 1500 535 160 45 21 /16 6 /16 1 3 /4 9,5 20,9 HF 32090
A
HF 094 2 494 1853 715 160 45 21 1/8 6 5/16 1 3 /4 12,2 26,9 HF 50090
HF 150 2 799 3000 715 160 45 21 1/8 6 5/16 1 3 /4 12,2 26,9 HF 51090
CORRECTION FACTORS
Operating pressure [bar] 3 5 7 10 13 16 20 30 40 50
1/2’’ Operating pressure [psi] 44 72 100 145 189 232 290 435 580 725
Correction factor 0,50 0,75 1 1,38 1,75 2,13 2,63 3,88 5,13 6,38
32
HF filter cartridges
Six filtration grades enables elimination of impurities from
compressed air in a temperature range 1,5 to 65 °C
(35 to 149°F).
HF 007 71 418 50/725 65/149** HF 6060 B HF 6060 P HF 6060 R HF 6060 M HF 6060 S HF 6060 A
HF 010 112 659 50/725 65/149** HF 7060 B HF 7060 P HF 7060 R HF 7060 M HF 7060 S HF 7060 A
HF 018 204 765 50/725 65/149** HF 12060 B HF 12060 P HF 12060 R HF 12060 M HF 12060 S HF 12060 A
HF 047 282 1059 50/725 65/149** HF 22090 B HF 22090 P HF 22090 R HF 22090 M HF 22090 S HF 22090 A
HF 070 400 1500 50/725 65/149** HF 32090 B HF 32090 P HF 32090 R HF 32090 M HF 32090 S HF 32090 A
HF 094 494 1853 50/725 65/149** HF 50090 B HF 50090 P HF 50090 R HF 50090 M HF 50090 S HF 50090 A
HF 150 799 3000 50/725 65/149** HF 51090 B HF 51090 P HF 51090 R HF 51090 M HF 51090 S HF 51090 A
B P R M S A
solid particle size purification: down to 15 microns 3 microns 1 micron 0,1 micron 0,01 micron -
residual oil content [mg/m3 / ppm] - - - 0,1 / 0,08 0,01 / 0,01 0,005 / 0,005
pressure drop - new element [mbar / psi] 30 / 0,43 40 / 0,58 <50 / 0,72 <80 / 1,16 120 / 1,74 <90 / 1,3
change filter cartridge at pressure drop [mbar / psi] 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 *every 6 months
filter material sintered brass acrile fibres, celulose borosilicate micro fibres active carbon
pleated version - + + + + -
wrapped version - + + + + +
sintered version + - - - - -
* Filter elements ’’A’’ must be changed periodically to suit application but at least every 6 months. Activated carbon filters must not operate
in oil saturated conditions.
64 bar
1,5 ÷ 65 °C
30 ÷ 720 Nm3/h
CORRECTION FACTORS
C Operating pressure [bar] 3 5 7 10 13 16 20 30 40 50 60 64
1/2’’
Operating pressure [psi] 44 72 100 145 189 232 290 435 580 725 870 928
Correction factor 0,63 0,88 1 1,38 1,75 2,13 2,63 3,88 5,13 6,38 7,63 8,13
34
AHP filter cartridges
Filter cartridges for high pressure applications are
designed for pressure range up to 64 bar.
AHP 005 30 17,6 64/928 65/149** AHP 06050 B AHP 06050 P AHP 06050 R AHP 06050 M AHP 06050 S AHP 06050 A
AHP 007 60 35,3 64/928 65/149** AHP 07050 B AHP 07050 P AHP 07050 R AHP 07050 M AHP 07050 S AHP 07050 A
AHP 010 120 70,6 64/928 65/149** AHP 14050 B AHP 14050 P AHP 14050 R AHP 14050 M AHP 14050 S AHP 14050 A
AHP 018 180 106 64/928 65/149** AHP 12075 B AHP 12075 P AHP 12075 R AHP 12075 M AHP 12075 S AHP 12075 A
AHP 030 270 159 64/928 65/149** AHP 22075 B AHP 22075 P AHP 22075 R AHP 22075 M AHP 22075 S AHP 22075 A
AHP 047 360 212 64/928 65/149** AHP 32075 B AHP 32075 P AHP 32075 R AHP 32075 M AHP 32075 S AHP 32075 A
AHP 094 720 423 64/928 65/149** AHP 51090 B AHP 51090 P AHP 51090 R AHP 51090 M AHP 51090 S AHP 51090 A
B P R M S A
solid particle size purification: down to 15 microns 3 microns 1 micron 0,1 micron 0,01 micron -
residual oil content [mg/m3 / ppm] - - - 0,1 / 0,08 0,01 / 0,01 0,005 / 0,005
pressure drop - new element [mbar / psi] 30 / 0,43 40 / 0,58 <50 / 0,72 <80 / 1,16 120 / 1,74 <90 / 1,3
change filter cartridge at pressure drop [mbar / psi] 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 *every 6 months
filter material sintered brass acrile fibres, celulose borosilicate micro fibres active carbon
pleated version - + + + + -
wrapped version - + + + + +
sintered version + - - - - -
* Filter elements ’’A’’ must be changed periodically to suit application but at least every 6 months. Activated carbon filters must not operate in oil
saturated conditions.
www.omega-air.si 35
industrial applications
Carbon steel high pressure filters CHP are used for industrial
high pressure applications up to 400 bar (5800 psi).
CORRECTION FACTORS
Operating pressure [bar] 7 25 40 64 100 250 400
C Operating pressure [psi] 100 362 580 928 1450 3625 5800
1/2’’ Correction factor 1 3 5 8 12 12 12
36
CHP filter cartridges
Filter cartridges for high pressure applications are designed for
pressure range up to 400 bar.
CHP 003 40 23,5 100/250/400 65/149** CHP 0305 B CHP 0305 P CHP 0305 R CHP 0305 M CHP 0305 S CHP 0305 A
CHP 005 70 41,2 100/250/400 65/149** CHP 0310 B CHP 0310 P CHP 0310 R CHP 0310 M CHP 0310 S CHP 0310 A
CHP 007 130 76,5 100/250/400 65/149** CHP 0420 B CHP 0420 P CHP 0420 R CHP 0420 M CHP 0420 S CHP 0420 A
CHP 010 195 115 100/250/400 65/149** CHP 0520 B CHP 0520 P CHP 0520 R CHP 0520 M CHP 0520 S CHP 0520 A
CHP 018 275 162 100/250/400 65/149** CHP 0525 B CHP 0525 P CHP 0525 R CHP 0525 M CHP 0525 S CHP 0525 A
CHP 030 380 223 100/250/400 65/149** CHP 0725 B CHP 0725 P CHP 0725 R CHP 0725 M CHP 0725 S CHP 0725 A
CHP 047 495 291 100/250/400 65/149** CHP 0730 B CHP 0730 P CHP 0730 R CHP 0730 M CHP 0730 S CHP 0730 A
CHP 094 715 421 100/250/400 65/149** CHP 1030 B CHP 1030 P CHP 1030 R CHP 1030 M CHP 1030 S CHP 1030 A
B P R M S A
solid particle size purification: down to 15 microns 3 microns 1 micron 0,1 micron 0,01 micron -
pressure drop - new element [mbar / psi] 30 / 0,43 40 / 0,58 <50 / 0,72 <80 / 1,16 120 / 1,74 <90 / 1,3
change filter cartridge at pressure drop [mbar / psi] 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 *every 6 months
filter material sintered brass acrile fibres, celulose borosilicate micro fibres active carbon
pleated version - + + + + -
wrapped version - + + + + +
sintered version + - - - - -
* Filter elements ’’A’’ must be changed periodically to suit application but at least every 6 months. Activated carbon filters must not operate in oil
saturated conditions.
www.omega-air.si 37
process applications
up to 150 °C
B 75 ÷ 21.120 Nm3/h
E
Flow rate
Connection Dimensions [mm] Mass Operating
at 7 bar(g), Filter’s
Filter model input & output pressure
20°C cartridge size
D [inch] A B C E [kg] [bar]
[Nm3/h]
PF 005 1/4’’ 75 200 116 76,1 1/4’’ 1,7 16 1x0310
PF 007 3/8’’ 105 231 120 76,1 1/4’’ 1,9 16 1x0410
PF 010 1/2’’ 150 231 125 76,1 1/4’’ 1,9 16 1x0420
PF 018 3/4’’ 225 253 125 76,1 1/4’’ 2,0 16 1x0520
PF 030 1’’ 315 272 136 88,9 1/4’’ 2,6 16 1x0525
PF 047 1 1/4’’ 420 334 155 88,9 1/4’’ 3,0 16 1x0725
PF 070 1 1/2’’ 600 386 180 114,3 1/4’’ 4,3 16 1x0730
PF 094 2’’ 900 453 180 114,3 1/4’’ 4,8 16 1x1030
PF 150 2’’ 1260 580 180 114,3 1/4’’ 5,3 16 1x1530
PF 175 2 1/2’’ 1680 740 224 139,7 1/4’’ 9,0 16 1x2030
PF 200 3’’ 2400 1008 224 139,7 1/4’’ 10,8 12 1x3030
PF 240 3’’ 3600 1040 255 168,3 1/4’’ 16,2 12 1x3050
PF 450 DN100 5040 986 410 219,1 1’’ 45 10 3x2030
PF 600 DN100 6720 1240 410 219,1 1’’ 46 10 3x3030
PF 900 DN150 9600 1300 480 273,0 1’’ 70 10 4x3030
PF 1200 DN150 13440 1350 540 323,9 1’’ 80 10 6x3030
PF 1800 DN200 17280 1500 660 406,4 1’’ 135 10 8x3030
PF 2000 DN200 21120 1500 660 406,4 1’’ 135 10 10x3030
38
PF filter cartridges
Process sintered stainless steel filter cartridges
are made of sintered stainless steel, which
unsures safety operating without risk for
corrosion.
www.omega-air.si 39
process applications
1/2’’
øC
50 bar
up to 150 °C
450 ÷ 7.200 Nm3/h
A
B
1/2’’
Flow rate
Dimensions [mm] Operating
Connection at 7 bar(g), Mass Filter’s
Filter model pressure
D [inch] 20°C [kg] cartridge size
A B C [bar]
[Nm3/h]
HPF 010/50 1/2’’ 450 243 108 76,1 2,5 50 1x0420
HPF 018/50 3/4’’ 715 266 125 76,1 2,6 50 1x0520
HPF 030/50 1’’ 1300 293 125 88,9 3,4 50 1x0525
HPF 047/50 1 1/4’’ 1800 344 140 88,9 3,9 50 1x0725
HPF 070/50 1 1/2’’ 2550 386 170 114,3 5,6 50 1x0730
HPF 094/50 2’’ 3150 460 170 114,3 6,2 50 1x1030
HPF 150/50 2’’ 5100 587 170 114,3 6,9 50 1x1530
HPF 200/50 3’’ 7200 987 216 139,7 14,1 50 1x3030
40
HPF filter cartridges
High pressure process filter cartridges can be made in 4
different versions:
- sintered inox,
- microfilter paper,
- active carbon,
- sterile.
www.omega-air.si 41
sterile applications
10 (16) bar
-20 ÷ 150 °C
75 ÷ 21.120 Nm3/h
D
B
E B
E
42
SF filter cartridges
Filter media are high quality borosilicate microfibres,
which eliminates up to 99,99% of Impurities sized
down to 0,01 μm.
www.omega-air.si 43
sterile & industrial applications
SPF filters are therefore made of high quality stainless steel for
pharmaceutical industry (quality 1.4301; on request 1.4404).
Housing is polished down to grade Ra 0,8.
Flow rate
Dimensions [mm] Operating
Connection at 7 bar(g), Mass Filter’s
Filter model pressure
D [inch] 20°C [kg] cartridge size E
A B C E [bar]
[Nm3/h] øC
SPF 005 1/4’’ 75 223 116 76,1 1/8’’ 1,7 16 1x0310
SPF 007 3/8’’ 105 254 120 76,1 1/8’’ 1,9 16 1x0410
SPF 010 1/2’’ 150 254 125 76,1 1/8’’ 1,9 16 1x0420
SPF 018 3/4’’ 225 276 125 76,1 1/8’’ 2,0 16 1x0520
SPF 030 1’’ 315 295 136 88,9 1/8’’ 2,6 16 1x0525
SPF 047 1 1/4’’ 420 357 155 88,9 1/8’’ 3,0 16 1x0725
A
SPF 070 1 1/2’’ 600 408 180 114,3 1/4’’ 4,3 16 1x0730
D
SPF 094 2’’ 900 476 180 114,3 1/4’’ 4,8 16 1x1030
SPF 150 2’’ 1260 602 180 114,3 1/4’’ 5,3 16 1x1530
SPF 175 2 1/2’’ 1680 762 224 139,7 1/4’’ 9,0 16 1x2030
SPF 200 3’’ 2400 1030 224 139,7 1/4’’ 10,8 12 1x3030 B
SPF 240 3’’ 3600 1062 255 168,3 1/4’’ 16,2 12 1x3050 E
44
SPF filter cartridges
High pressure process filter cartridges can be made in 4
different versions:
- sintered inox,
- microfilter paper,
- active carbon,
- sterile.
www.omega-air.si 45
vacuum applications
P-VAC filters have been specifically developed for protection of vacuum pumps.
These filters are optimised for high-efficient removal of solid particles and other
contamination from the suction side of vacuum pumps preventing damage to the
pump.
Rough prefilter “VACP”removes bulk liquid and large solid particles while high
efficiency microfilter VACM removes very fine impurities which may damage the
pump.
APPLICATIONS
• vacuum pumps
pVAC 0476 1 1/2’’ 63,8 37,5 191 112 461 125 140 32075 VACP, VACM
pVAC 0706 1 1/2’’ 97,5 57,4 292 172 640 125 160 50075 VACP, VACM
pVAC 0946 2’’ 125 73,6 375 221 684 163 520 51090 VACP, VACM
pVAC 1506 2’’ 187 110 563 331 935 163 770 76090 VACP, VACM
D
pVAC 1756 2 1/2’’ 210 123 630 371 935 163 770 76090 VACP, VACM
pVAC 2006 3’’ 270 159 811 477 795 240 630 51140 VACP, VACM
pVAC 2406 3’’ 345 203 1036 609 1000 240 780 75140 VACP, VACM
Replace filter cartridge every 12 months or follow the instructions for specific filter element.
46
vacuum applications
M-VAC filters are designed for medical vacuum applications. These filters are
optimised for high-efficient removal of bacterial and other contamination (solids
and liquids) from the suction side of vacuum pumps preventing damage to the
pump and the potential biological infection of the surrounding environment.
Removed liquids are collected in a transparent flask which can be removed for
sterilisation.
The efficiency of the installed filter elements exceeds the 0,005% penetration
specified in HTM 2022 for infections disease units, when tested in accordance with
BS 3928.
APPLICATIONS
• operating theatres
• maternity units
• dental applications
• pathology laboratories
A
• pharmaceutic applications
• mortuary and post-mortem rooms 20 ÷ 2000 mbar (abs)
1.5 ÷ 65 °C
7.5 ÷ 787 Nm3/h
120
D
D
Replace filter cartridge every 12 months or follow the instructions for specific filter element. Used filter cartridges
must be treated as bio-hazardous and must be removed according to valid local laws !
www.omega-air.si 47
special applications
CNG filters are designed for high efficient removal of solid particles
and bulk liquids from compressed natural gas.
APPLICATIONS:
20 bar
1.5 ÷ 65 °C
72 ÷ 2.760 Nm3/h
CORRECTION FACTORS
Operating pressure [bar] 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Operating pressure [psi] 29 44 58 72 87 100 115 130 145 160 174 189 203 218 232 247 261 276 290
Correction factor 0,38 0,5 0,63 0,75 0,88 1 1,13 1,25 1,38 1,50 1,63 1,75 1,88 2,00 2,13 2,25 2,38 2,50 2,63
48
CNG filter elements are used for high efficient removal of solid
particles, oil aerosols and water from compressed natural gas.
For any other technical gas please contact producer or your local
dealer.
Replace filter element at least every 12 months or when pressure drop reaches 350 mbar.
www.omega-air.si 49
special applications
Microfilter
S 0,01μm
M 0,1μm
CKL-PP
• • • B
PP-207 1/2’’ 78 380 135 276 2
PP-210 1/2’’ 120 380 135 345 • • • 2
PP-307 1/2’’ 78 490 135 276 • • • • 2
PP-310 1/2’’ 120 490 135 345 • • • • 2
PP-407 1/2’’ 78 580 135 276 • • • • 4
0 ÷ 16 bar
PP-410 1/2’’ 120 580 135 345 • • • • 4
PP-507 1/2’’ 78 612 135 370 • • • • 4
1,5 ÷ 65 °C
PP-510 1/2’’ 120 612 135 440 • • • • 4
PP-607 1/2’’ 78 1150 335 917 • • • • • 4
78 ÷ 235 Nm3/h
PP-610 1/2’’ 120 1150 335 917 • • • • • 4
50
sšpecial applications
DESCRIPTION
B-AIRTM point of use filter set has been specifically developed for high
efficient preparation of top quality breathing air. On request B-AIRTM
filter set can be supplied with wall mounting brackets, pressure
regulator and quick couplings.
APPLICATIONS
· Breathing air
Flow rate
Dimensions [mm] Mass Filter
Filter set Connection (7 bar, 20°C)
3
[kg] element
Nm /h scfm A B C D
B-AIR 0076 1/2’’ 78 46 187 88 20 60 0,7 07050 (S+H2+A2)
B-AIR 0106 3/4’’ 120 70 257 88 20 80 0,8 14050 (S+H2+A2)
B-AIR 0186 1’’ 198 116 263 125 32 100 1,8 12075 (S+H2+A2)
B-AIR 0306 1’’ 335 197 363 125 32 120 2,5 22075 (S+H2+A2) 0 ÷ 16 bar
B-AIR 0476 1 1/2’’ 510 300 461 125 32 140 2,5 32075 (S+H2+A2)
B-AIR 0706 1 1/2’’ 780 459 640 125 32 160 3,2 50075 (S+H2+A2) 1,5 ÷ 45 °C
CORRECTION FACTORS
78 ÷ 780 Nm3/h
Operating pressure [bar] 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Operating pressure [psi] 29 44 58 72 87 100 115 130 145 160 174 189 203 218 232
Correction factor 0,38 0,5 0,63 0,75 0,88 1 1,13 1,25 1,38 1,50 1,63 1,75 1,88 2,00 2,13
www.omega-air.si 51
filtration
AFs filters have been specifically developed for applications in paint industry.
These filters are free of substances that could cause defects in paint aplications
and provide, high efficient removal of water, oil aerosols, hydrocarbons and odour
vapors from compressed air systems.
To meet the required compressed air quality appropriate “paint compatible” filter
element (B, P, R, M, S, A) must be installed into filter housing.
APPLICATIONS:
• painting applications
• automotive industry
0 ÷ 16 bar
1,5 ÷ 65 °C
60 ÷ 2760 Nm3/h
Flow rate B
Dimensions [mm] Filter
at 7 bar(g), 20°C Mass
Filter model Connection cartridge
[kg]
80
AFs 0306 1’’ 335 197 363 125 32 120 2,5 22075
AFs 0476 1 1/2’’ 510 300 461 125 32 140 2,5 32075
AFs 0706 1 1/2’’ 780 459 640 125 32 160 3,2 50075
AFs 0946 2’’ 1000 588 684 163 43 520 5,1 51090
AFs 1506 2’’ 1500 882 935 163 43 770 7,1 76090
AFs 1756 2 1/2’’ 1680 990 935 163 43 770 6,9 76090 R 1/2’’
D
AFs 2006 3’’ 2160 1270 795 240 59 630 12,9 51140
AFs 2406 3’’ 2760 1620 1000 240 59 780 14,0 75140
CORRECTION FACTORS
Operating pressure [bar] 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Operating pressure [psi] 29 44 58 72 87 100 115 130 145 160 174 189 203 218 232
Correction factor 0,38 0,5 0,63 0,75 0,88 1 1,13 1,25 1,38 1,50 1,63 1,75 1,88 2,00 2,13
52
Filter elements have been specifically developed for applications
in paint industry. Elements are free of substances that could cause
defects in paint aplications and provide, high efficient removal of
water, oil aerosols, hydrocarbons and odor vapors from compressed
air systems.
Replace filter element at least every 12 months or when pressure drop reaches 350 mbar.
www.omega-air.si 53
alternative solutions
V 1030
end caps
V-PE 2/1 Z
end caps
ZV06040/P
ZANDER
Z 1030
end caps
FF 2/1 Z
end caps
/
ZANDER
Y 1030
end caps
MF 2/1 Z
end caps
ZY06040/M
V 1050 V-PE 2/1,5 Z ZV06050/P Z 1050 FF 2/1,5 Z / Y 1050 MF 2/1,5 Z ZY06050/M
V 1070 V-PE 3/1,5 Z ZV07050/P Z 1070 FF 3/1,5 Z / Y 1070 MF 3/1,5 Z ZY07050/M
V 1140 V-PE 5/1,5 Z ZV14050/P Z 1140 FF 5/1,5 Z / Y 1140 MF 5/1,5 Z ZY14050/M
V 2010 V-PE 4/2,5 Z ZV12075/P Z 2010 FF 4/2,5 Z / Y 2010 MF 4/2,5 Z ZY12075/M
V 2020 V-PE 8/2,5 Z ZV22075/P Z 2020 FF 8/2,5 Z / Y 2020 MF 8/2,5 Z ZY22075/M
V 2030 V-PE 12/2,5 Z ZV32075/P Z 2030 FF 12/2,5 Z / Y 2030 MF 12/2,5 Z ZY32075/M
V 2050 V-PE 20/2,5 Z ZV50075/P Z 2050 FF 20/2,5 Z / Y 2050 MF 20/2,5 Z ZY50075/M
V 3050 V-PE 20/3 Z ZV51090/P Z 3050 FF 20/3 Z / Y 3050 MF 20/3 Z ZY51090/M
V 3075 V-PE 30/3 Z ZV76090/P Z 3075 FF 30/3 Z / Y 3075 MF 30/3 Z ZY76090/M
V 5075 V-PE 30/5 Z ZV75140/P Z 5075 FF 30/5 Z / Y 5075 MF 30/5 Z ZY75140/M
54
alternative solutions
OMI OMI
≤ 2003
OMI
> 2003
Plastic
end caps
OMI
≤ 2003
OMI
> 2003
Plastic
end caps
0004QF 0005QF OQF0004/P 0004PF 0005PF OPF0004/M
0008QF 0010QF OQF0008/P 0008PF 0010PF OPF0008/M
0016QF 0018QF OQF0016/P 0016PF 0018PF OPF0016/M
/ 0030QF OQF0030/P / 0030PF OPF0030/M
0025QF 0034QF OQF0025/P 0025PF 0034PF OPF0025/M
0036QF 0050QF OQF0036/P 0036PF 0050PF OPF0036/M
/ 0072QF OQF0072/P / 0072PF OPF0072/M
0060QF 0095QF OQF0060/P 0060PF 0095PF OPF0060/M
0070QF / OQF0070/P 0070PF / OPF0070/M
0090QF 0125QF OQF0090/P 0090PF 0125PF OPF0090/M
0120QF 0165QF OQF0120/P 0120PF 0165PF OPF0120/M
/ 0190QF OQF0190/P / 0190PF OPF0190/M
0185QF 0220QF OQF0185/P 0185PF 0220PF OPF0185/M
/ 0280QF OQF0280/P / 0280PF OPF0280/M
/ 0350QF OQF0350/P / 0350PF OPF0350/M
/ 0440QF OQF0440/P / 0440PF OPF0440/M
OMI OMI Plastic OMI OMI Plastic
≤ 2003 > 2003 end caps ≤ 2003 > 2003 end caps
0004HF 0005HF OHF0004/S 0004CF 0005CF OCF0004/A
0008HF 0010HF OHF0008/S 0008CF 0010CF OCF0008/A
0016HF 0018HF OHF0016/S 0016CF 0018CF OCF0016/A
/ 0030HF OHF0030/S / 0030CF OCF0030/A
0025HF 0034HF OHF0025/S 0025CF 0034CF OCF0025/A
0036HF 0050HF OHF0036/S 0036CF 0050CF OCF0036/A
/ 0072HF OHF0072/S / 0072CF OCF0072/A
0060HF 0095HF OHF0060/S 0060CF 0095CF OCF0060/A
0070HF / OHF0070/S 0070CF / OCF0070/A
0090HF 0125HF OHF0090/S 0090CF 0125CF OCF0090/A
0120HF 0165HF OHF0120/S 0120CF 0165CF OCF0120/A
/ 0190HF OHF0190/S / 0190CF OCF0190/A
0185HF 0220HF OHF0185/S 0185CF 0220CF OCF0185/A
/ 0280HF OHF0280/S / 0280CF OCF0280/A
/ 0350HF OHF0350/S / 0350CF OCF0350/A
/ 0440HF OHF0440/S / 0440CF OCF0440/A
www.omega-air.si 55
alternative solutions
DONALDSON - DONALDSON
Aluminium
end caps
Plastic
end caps
DONALDSON
Aluminium
end caps
Plastic
end caps
90 series PE 02/05
PE 03/05
PE 02/05
PE 03/05
UPE0205
UPE0305
FF 02/05
FF 03/05
FF 02/05
FF 03/05
UFF0205
UFF0305
PE 03/10 PE 03/10 UPE0310 FF 03/10 FF 03/10 UFF0310
PE 04/10 PE 04/10 UPE0410 FF 04/10 FF 04/10 UFF0410
PE 04/20 PE 04/20 UPE0420 FF 04/20 FF 04/20 UFF0420
PE 05/20 PE 05/20 UPE0520 FF 05/20 FF 05/20 UFF0520
PE 05/25 PE 05/25 UPE0525 FF 05/25 FF 05/25 UFF0525
PE 07/25 PE 07/25 UPE0725 FF 07/25 FF 07/25 UFF0725
PE 07/30 PE 07/30 UPE0730 FF 07/30 FF 07/30 UFF0730
PE 10/30 PE 10/30 UPE1030 FF 10/30 FF 10/30 UFF1030
PE 15/30 PE 15/30 UPE1530 FF 15/30 FF 15/30 UFF1530
PE 20/30 PE 20/30 UPE2030 FF 20/30 FF 20/30 UFF2030
PE 30/30 PE 30/30 UPE3030 FF 30/30 FF 30/30 UFF3030
PE 30/50 PE 30/50 UPE3050 FF 30/50 FF 30/50 UFF3050
DONALDSON - DONALDSON
Aluminium
end caps
Plastic
end caps
DONALDSON
Aluminium
end caps
Plastic
end caps
80 series PE 03/1
PE 03/1,5
PE 03/1
PE 03/1,5
UPE031/P
UPE031.5/P
FF 03/1
FF 03/1,5
FF 03/1
FF 03/1,5
UFF031/M
UFF031.5/M
PE 04/1,5 PE 04/1,5 UPE041.5/P FF 04/1,5 FF 04/1,5 UFF041.5/M
PE 04/2,5 PE 04/2,5 UPE042.5/P FF 04/2,5 FF 04/2,5 UFF042.5/M
PE 05/2,5 PE 05/2,5 UPE052.5/P FF 05/2,5 FF 05/2,5 UFF052.5/M
PE 05/3 PE 05/3 UPE053/P FF 05/3 FF 05/3 UFF053/M
PE 10/3 PE 10/3 UPE103/P FF 10/3 FF 10/3 UFF103/M
PE 15/3 PE 15/3 UPE153/P FF 15/3 FF 15/3 UFF153/M
PE 20/3 PE 20/3 UPE203/P FF 20/3 FF 20/3 UFF203/M
PE 30/3 PE 30/3 UPE303/P FF 30/3 FF 30/3 UFF303/M
PE 30/5 PE 30/5 UPE305/P FF 30/5 FF 30/5 UFF305/M
56
alternative solutions
BOGE BOGE
Plastic
end caps
BOGE
Plastic
end caps
BOGE
Plastic
end caps
1/5 V 1/5 P 1/5 FP 1/5 S 1/5 A 1/5 A
1/10 V 1/10 P 1/10 FP 1/10 S 1/10 A 1/10 A
1/12 V 1/12 P 1/12 FP 1/12 S 1/12 A 1/12 A
1/20 V 1/20 P 1/20 FP 1/20 S 1/20 A 1/20 A
1/30 V 1/30 P 1/30 FP 1/30 S 1/30 A 1/30 A
1/50 V 1/50 P 1/50 FP 1/50 S 1/50 A 1/50 A
1/80 V 1/80 P 1/80 FP 1/80 S 1/80 A 1/80 A
1/120 V 1/120 P 1/120 FP 1/120 S 1/120 A 1/120 A
1/160 V 1/160 P 1/160 FP 1/160 S 1/160 A 1/160 A
1/250 V 1/250 P 1/250 FP 1/250 S 1/250 A 1/250 A
www.omega-air.si 57
alternative solutions
58
other products
D
Connections number and dimensions Dimensions (mm)
Max.
Volume Mass
DN100
DN150
Size pressure
DN50
DN80
1/2’’
3/4’’
6/4’’
(l) (kg)
1’’
2’’
H D L (bar)
Oil separation
60
other products
BS 12-3,5 AWS
BS Tower
PETRO-PACK
www.omega-air.si 61
other products
Terrain compressors
CB 600 CD 600
Compressor with petrol engine Compressor with diesel engine
Features: Features:
- compression unit with cast iron cylinder (two stage - compression unit with cast iron cylinder (two stage
compression), compression),
- petrol engine, - diesel engine,
- suction filter, - suction filter,
- compressed air cooling system, - compressed air cooling system,
- two pressure vessels with CE certificate, - two pressure vessels with CE certificate,
- certified safety valve, - certified safety valve,
- ait treatment unit with couplings and pressure gauge, - ait treatment unit with couplings and pressure gauge,
- non-returning valve with regulating valve, - non-returning valve with regulating valve,
- transport tyres, - transport tyres,
- condensate drain valve, - condensate drain valve,
- separated connections for pneumatic tools, - separated connections for pneumatic tools,
- automatic operating control, - automatic operating control,
- high air capacity, - rough construction,
- rough construction, - max. pressure control (up to 10 bar) - option,
- max. pressure control (up to 10 bar) - option, - pneumatic tool oiling,
- pneumatic tool oiling, - remarkable mobile,
- remarkable mobile, - easy transport and use.
- easy transport and use.
Technical data:
Technical data: - pressure vessel capacity: 50+50 ltr
- pressure vessel capacity: 50+50 ltr - max. operating pressure: 10 bar
- max. operating pressure: 10 bar - capacity (ISO 1217): 600 Nl/min
- capacity (ISO 1217): 600 Nl/min - power transmittion: belt
- max. speed: 900 rpm - max. speed: 900 rpm
- cylinder/piston/stage Nr.: 1/2/2 - cylinder/piston/stage Nr.: 1/2/2
- engine type: Honda GX 270 - main shaft power: 8 HP
- main shaft power: 9 HP - working volume: 349 cm3
- working volume: 270 cm3 - fuel: diesel
- fuel: unleaded petrol 95 - engine start: manual
- engine start: manual - dimensions L/B/H: 1070 / 920 / 1100 mm
- dimensions L/B/H: 1070 / 920 / 1100 mm - mass: 173 kg
- mass: 173 kg
62
other products
Benefits:
- all in one unit (compressors, dryer, pressure vessel, filters,
separators...),
- compressed air hireing in the case of service or refit,
- quick response in the case of compressor breakdown,
- guarantee for clean air,
- easy connection to existent compressed air system,
- exterior placing regardless to weather conditions,
- possibility for permanent placing as basic compressed
air station,
- easy transport with forklift and truck.
www.omega-air.si 63
OmegaAir
64
OmegaAir
www.omega-air.si 65
... from A to Z .
66
Austria Austria
Exit № 35
Europe,
Slovenia
Ljubljana
OMEGA AIR d.o.o. Ljubljana
LJUBLJANA Cesta Dolomitskega odreda 10
SI-1000, Ljubljana, Slovenia
GPS coordinates:
N: 46° 2’ 27.13’’
E: 14° 27’ 59.46’’
CUSTOMISED PRODUCTS
A large part of our manufacturing capacity is suited for customized products. We take part in the developing of the products together with our customers.
If you have a project in our range of products and need a co-operating partner do not hesitate to contact us.
The above mentioned sales terms and conditions are only for information. All other details are defined in writen agreement between contract parties.
www.omega-air.si 67
OMEGA AIR d. o. o. Ljubljana
Cesta Dolomitskega odreda 10
1000 Ljubljana, Slovenia
tel: +386 (0)1 200 68 00
fax: +386 (0)1 200 68 50
e-mail: info@omega-air.si
www.omega-air.si
Concerning all furnished data, we reserve the right to make alterations to the constructive design, dimensions and technical specifications!