Fault Tree
Fault Tree
Fault Tree
Blowout of well
AND
Explosion
BOP Failure
AND
AND
Loss control of
the well
Failure Pipe Failure Annular Failure Cutting
Vapor Ignition
Ram Preventer Pipes
OR
AND OR OR
OR
Failure of Failure
cement log monitoring well Failure of Blind
Failure of test Failure Presence of Late Late
Failure in Mechanic Shear Blades Buckling
readings of Alarm flammable response response
closing Failure Pipes
OR System gases of staff of staff
OR
OR
Management Mechanic
Failure Failure
Failure Incorrect
mixture placement Failure Deadman
Failure (AMF)
& design of cement in EDS
Misinterpre- Failure in Buttons
tation of measurement Failure of
readings of pressure solenoid valves
AND
Failure Failure
of Yellow of Blue
Pod Pod