PCS-9671S X Selection Guide en Overseas General X R1.03

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 44

Copyright © 2021 NR. All rights reserved.

NR, the NR logo are either registered trademarks or trademarks of NR Electric Co., Ltd. No NR
trademarks may be used without written permission. NR products appearing in this document may
be covered by P.R. China and foreign patents. NR Electric Co., Ltd. reserves all rights and
benefits afforded under P.R. China and international copyright and patent laws in its products,
including but not limited to software, firmware and documentation. NR Engineering Co., Ltd. is
licensed to use this document as well as all intellectual property rights owned or held by NR
Electric Co., Ltd, including but not limited to copyright, rights in inventions, patents, know-how,
trade secrets, trademarks and trade names, service marks, design rights, database rights and
rights in data, utility models, domain names and all similar rights.

The information in this document is provided for informational use only and does not constitute a
legal contract between NR and any person or entity unless otherwise specified. Information in this
document is subject to change without prior notice.

To the extent required the products described herein meet applicable IEC and IEEE standards,
but no such assurance is given with respect to local codes and ordinances because they vary
greatly.

Although every reasonable effort is made to present current and accurate information, this
document does not purport to cover all details or variations in equipment nor provide for every
possible contingency to be met in connection with installation, operation, or maintenance. Should
further information be desired or should particular problems arise which are not covered
sufficiently for your purposes, please do not hesitate to contact us.
Preface

Preface

About This Manual


The selection guide describes the application overview and the summary of protection,
automation and supervision functions of PCS-9671S. Moreover, it provides the explanation about
the application option, the firmware option, the software option, the hardware option and etc., and
can be used to indicate how to order a PCS-9671S based on expected configurations.

Warranty
NR can provide up to 10-year warranty for this product. For warranty details, please consult the
manufacturer or agent for warranty information.

Document Structure
This manual is mainly for the overview of the application and functions of the PCS-9671S, and it
provides the configuration of software and hardware information for ordering. An overview of each
manual section and section topics follows.

1 Functions and Applications


Introduces the summary functions of this device, such as the protection, the automation and the
supervision. Briefly introduces the typical application schemes of PCS-9671S.

2 Guide of PCS-Torch
Introduces the main functions of PCS-Torch, including create new project, create new device,
export MOT and Manage MOT library, MOT configuration interface and the structure of the
ordering code.

3 MOT Information
Introduces the meaning and options of each field, and gives a detailed description about the
selection rule for the application, the firmware, the software, the hardware, the chassis structure
and so on.

Document Revision History


PN: ZL_PCS-9671S_X_Selection Guide_EN_Overseas General_X

Current version: R1.03

Corresponding Version
Date Description of change
Document Software

R1.00 R1.11 2020-02-17  Form the original manual.

PCS-9671S Transformer Relay I


Date: 2021-06-30
Preface

 Added PWR plug-in module NR6311A.

 Added CPU plug-in module NR6106AH.


R1.01 R1.11 2020-06-08
 Added CPU plug-in module NR6106AP.

 Added BIBO plug-in module NR6661A.

 Added reactor protection application scenario.

R1.02 R1.12 2020-12-09  Added reactor current differential protection function 87R.

 Added BO plug-in module NR6663A.

 Added BI plug-in module NR6604A and NR6611A for

binary inputs with high power conducting mode


R1.03 R1.13 2021-06-30
 Added DC AI module NR6630A

 Added DC AO module NR6632A

II PCS-9671S Transformer Relay


Date: 2021-06-30
1 Functions and Applications

1 Functions and Applications


1
Table of Contents

1.1 General ............................................................................................................. 1-1


1.2 Protection Functions ....................................................................................... 1-1
1.3 Measurement and Metering Functions .......................................................... 1-2
1.4 Supervision Functions .................................................................................... 1-2
1.5 Communication Functions ............................................................................. 1-2
1.6 User Interfaces ................................................................................................. 1-3
1.7 Additional Functions ....................................................................................... 1-3
1.8 Typical Applications ........................................................................................ 1-4

List of Figures

Figure 1.8-1 Typical application of a 2-winding transformer .................................................1-4

Figure 1.8-2 Typical application of a 3-winding transformer .................................................1-5

Figure 1.8-3 Typical application of an auto-transformer ........................................................1-5

Figure 1.8-4 Typical application of a reactor ...........................................................................1-6

PCS-9671S Transformer Relay 1-a


Date: 2021-06-30
1 Functions and Applications

1-b PCS-9671S Transformer Relay


Date: 2021-06-30
1 Functions and Applications

1.1 General

PCS-9671S transformer relay has been designed specifically for the protection of various type
1
power transformers (up to 3 measuring points), including two-winding transformers, three-winding
transformers, auto-transformers, as well as reactors. Ancillary functions of fault diagnostic,
disturbance records, event records and communication function are integrated in the device. With
its modular structure, flexibility and the powerful PCS-Studio engineering tool, PCS-9671S offers
future-oriented system solutions with high investment security and low operating costs.

1.2 Protection Functions

ANSI Protection Functions Remark


 Biased differential protection with three slopes
 Biased DPFC differential protection
 Unrestrained instantaneous differential protection
 Optional inrush current distinguished principles:
harmonic criterion or waveform distortion
 Optional harmonic blocking modes: self-adaptive
87T Transformer differential protection
1Pblk1P mode, 2PBlk3P mode, 1Pblk3P mode
 Overexcitation detection: fifth harmonic or third
harmonic criterion
 Optional transfer methods: △→Y or Y→△
 Independent CT saturation criterion
 Differential CT circuit failure supervision
 Biased current differential protection.
 Unrestrained instantaneous differential protection
87R Reactor differential protection  Independent CT saturation criterion.
 Harmonic blocking criterion.
 Differential CT circuit failure supervision.
 CT transient characteristic difference detection
64REF Restricted earth-fault protection  CT saturation detection based on 2nd and 3rd
harmonics
 2 stages with independent logic by default for each
side
 Optional definite-time characteristic and inverse-time
50/51P Phase overcurrent protection
characteristic for each stage
 Trip purpose or alarm purpose for each stage
 Harmonic control element for each stage

PCS-9671S Transformer Relay 1-1


Date: 2021-06-30
1 Functions and Applications

 2 stages with independent logic by default for each


side

1 Optional measured zero-sequence
calculated zero-sequence current
current or

50/51G Earth fault protection  Optional definite-time characteristic and inverse-time


characteristic for each stage
 Selectable trip purpose or alarm purpose for each
stage
 Harmonic control element for each stage

1.3 Measurement and Metering Functions

 Positive sequence currents, zero sequence currents and phase angles

 DC analogue inputs (0~±20mA or 0~±10V)

 DC analogue outputs (4~20mA, 0~10V, 0~5V or 0~20mA)

1.4 Supervision Functions

 CT circuit failure supervision (CTS)

 Self diagnosis

 Powerful faults recording (max. buffer for 10,000 sampled points at 1.2 or 9.6 kHz)

 Event Recorder including 1024 disturbance records, 1024 binary events, 1024
supervision events, 256 control logs and 1024 device logs.

 Disturbance recorder including 64 disturbance records with waveforms (The file format of
disturbance recorder is compatible with international COMTRADE file.)

 Single line diagram representation in display

1.5 Communication Functions

 Support of various protocols

Modbus, DNP3.0, IEC 60870-5-103, IEC 61850 Ed.1 & Ed.2, IEC 61850 MMS Server,
IEC 61850-8-1 GOOSE, IEC 62439 Parallel Redundancy Protocol (PRP), IEC 62439
High-availability Seamless Ring (HSR) Redundancy Protocol, IEEE 802.1w Rapid
Spanning Tree Protocol (RSTP).

 Up to four 10Base-T/100Base-TX copper Ethernet ports

 Up to four 100Base-FX optical Ethernet ports

 Two RS-485 serial ports for communication, the second one could be used as a RS-232

1-2 PCS-9671S Transformer Relay


Date: 2021-06-30
1 Functions and Applications

port for printer

 One RS-485/TTL serial port for clock synchronization

 One BNC port for clock synchronization


1
 One ST-connector port for clock synchronization

 Two RJ45 debugging ports (front and rear)

1.6 User Interfaces

 Friendly HMI interface with LCD, easy-to-use keypad aids simple navigation and
set-point adjustment

 Push buttons for open/close, switch for selection between local and remote control, and
user's login and logout authority management

 4 Programmable operator pushbuttons with user-configurable labels

 Up to 15 programmable target LEDs with user-configurable labels

 1 RS-232 or RS-485 rear ports for printer

 Language switchover—English+ selected language

 Configuration tool—PCS-Studio

1.7 Additional Functions

 User programmable logic

 Switching system phase sequences function (ABC or ACB)

 Clock synchronization

 IRIG-B: IRIG-B via RS-485 differential level, TTL level, BNC or ST-connector port

 PPS: Pulse per second (PPS) via RS-485 differential level, binary input, BNC or
ST-connector port

 IEEE 1588: Clock message based on IEEE 1588 via Ethernet network

 SNTP (PTP): Unicast (point-to-point) SNTP mode via Ethernet network

 SNTP (BC): Broadcast SNTP mode via Ethernet network

 Message (IEC103/Modbus/DNP3.0): Clock messages through IEC103 protocol,


Modbus protocol and DNP3.0 protocol

 Cyber security

 NERC CIP

PCS-9671S Transformer Relay 1-3


Date: 2021-06-30
1 Functions and Applications

 IEC 62351

 IEC 62443
1  IEEE 1686

1.8 Typical Applications

PCS-9671S can be applied for a two-winding transformer, three-winding transformer,


auto-transformer or reactor, mostly in 110kV voltage level and below.

HVS

52

*
3CT

64 50/ 50/
87T
REF 51P 51G

1CT

3CT
*

52

LVS

Figure 1.8-1 Typical application of a 2-winding transformer

1-4 PCS-9671S Transformer Relay


Date: 2021-06-30
1 Functions and Applications

HVS

52

3CT
* 1

64 50/ 50/
87T
REF 51P 51G
MVS
*

52 1CT
*
3CT

3CT
*

52

LVS

Figure 1.8-2 Typical application of a 3-winding transformer

HVS

52

*
3CT

64 50/ 50/
MVS 87T
REF 51P 51G

*
52
*
3CT 1CT

3CT
*

52

LVS

Figure 1.8-3 Typical application of an auto-transformer

PCS-9671S Transformer Relay 1-5


Date: 2021-06-30
1 Functions and Applications

Bus

1 52

50/ 50/
87R
51P 51G

*
3 CT

3 CT
*

1 CT
*

Figure 1.8-4 Typical application of a reactor

1-6 PCS-9671S Transformer Relay


Date: 2021-06-30
2 Guide of PCS-Torch

2 Guide of PCS-Torch

Table of Contents

2.1 Introduction ...................................................................................................... 2-1 2


2.2 Create New Project .......................................................................................... 2-1
2.3 Create New Device .......................................................................................... 2-2
2.4 Project Management........................................................................................ 2-4
2.5 MOT Configuration Interface .......................................................................... 2-6
2.6 Ordering Code ................................................................................................. 2-7
2.7 Export MOT ...................................................................................................... 2-8
2.8 MOT Library Management............................................................................. 2-10

List of Figures

Figure 2.2-1 Project navigation when ordering IEDs ..............................................................2-1

PCS-9671S Transformer Relay 2-a


Date: 2021-06-30
2 Guide of PCS-Torch

2-b PCS-9671S Transformer Relay


Date: 2021-06-30
2 Guide of PCS-Torch

2.1 Introduction

The PCS-Torch is an auxiliary ordering tool for the PCS S series products of NR Electric. It is
recommended to run on a MS Windows 7/10 operating system.

This tool helps to create a complete order code with detailed specifications based on the selection
of functional options such as software and hardware. This tool supports engineering methods to
2
create models of various types of the PCS S series protection, measurement and control devices
in power substations, and can view or select device hardware and software configurations before
sales. Meanwhile, it could preview device rear modules, and import or export the device
configuration results in the form of Excel table.

The model library of all the types of device could be updated online automatically or offline
manually to facilitate the access of the latest functions of PCS S series devices.

2.2 Create New Project

PCS-Torch manages a project according to the structure of "Project (Substation)"→"Voltage


Level"→"Bay"→"Device" as shown in Figure 2.2-1, however, it also supports to create a new
device under the node of "Substation" or "Voltage Level" directly.

Click the button “New” to create a new


Project (Substation)
project sorted by substation name

Right-click the menu “New voltage


Voltage Level
level...” to create a new voltage level

Right-click the menu “New bay...” to


Bay create a new bay

Right-click the menu “New device...” to


Device create a new device

Right-click the menu “New device...” to


Device create a new device

Right-click the menu “New device...” to


Device create a new device

Figure 2.2-1 Project navigation when ordering IEDs

 Create several voltage levels or devices under the project node

PCS-9671S Transformer Relay 2-1


Date: 2021-06-30
2 Guide of PCS-Torch

 Create several bays or devices under the voltage level node

 Create several devices under the bay node

2.3 Create New Device

Button Remark

Create a new project

2-2 PCS-9671S Transformer Relay


Date: 2021-06-30
2 Guide of PCS-Torch

Open an existing project

Save the current project

Update the MOT (Market Ordering Table) library online

Import the MOT library locally 2


Right-click the menu "New device..." under the node of project, voltage level or bay to create a
new device.

 By MOT lib

In the pop-up dialog box, enter the device name, select the device type and MOT version or
firmware version.

 Based on MOT version

Select the main MOT version (R1, R2……) so that PCS-Torch will automatically search
the latest archived firmware version corresponding to such main MOT version, and
create the MOT configuration.

Main MOT version is compatible with all firmware versions that begin with
main MOT version (except disabled firmware version). For example, if
main MOT version is "R1", it is compatible with all firmware version R1.**.

 Based on firmware version

Input the firmware version so that PCS-Torch will create the device MOT configuration
according to such firmware version automatically except that the input firmware version
is disabled or does not exist.

PCS-9671S Transformer Relay 2-3


Date: 2021-06-30
2 Guide of PCS-Torch

 By MOT code

In the pop-up dialog box, enter the required MOT code.

 Without specific firmware version

PCS-Torch will automatically search the latest archived firmware version corresponding
to main MOT version, and create the MOT configuration.

 With specific firmware version

PCS-Torch will create the device MOT configuration according to such firmware version
automatically except that the input firmware version is disabled or does not exist.

2.4 Project Management

PCS-Torch can export MOT information of a whole substation, and supports the operations of
copy, paste and rename.

2-4 PCS-9671S Transformer Relay


Date: 2021-06-30
2 Guide of PCS-Torch

PCS-Torch can manage only one project (substation), so please open


multiple instances of PCS-Torch while executing cross-project copy and
paste operations.

Right-click the menu under the project (substation) node, and select the menu item "Export
station information". An excel file that includes MOT codes and modules configuration
information of all devices in the project will be generated, as shown below.

PCS-9671S Transformer Relay 2-5


Date: 2021-06-30
2 Guide of PCS-Torch

2.5 MOT Configuration Interface

In the MOT configuration interface, the integral ordering code is displayed at the top. The detailed
MOT information is shown in a row/column format. The first column indicates MOT item, the
second column indicates available options corresponding to each item, the third column indicates
the description about the chosen option, and the fourth column indicates the ordering code
corresponding to the chosen option.

Double-click the cell in the "Option" column to switch the option from drop-down box. When the
contents of the cell in the "Option" column is changed, the corresponding contents of the
"Description" and "Code" columns in the same row are changed synchronously, and the
corresponding bit of ordering code is also changed synchronously. There is possibly a mandatory
binding rule or mutual exclusion rule among MOT items. The option will be chosen fixedly if an
option's mandatory binding rule is activated. The option will be hidden if an option's mutual
exclusion rule is activated. For an option that is not applicable, the row is grey and not selectable.

2-6 PCS-9671S Transformer Relay


Date: 2021-06-30
2 Guide of PCS-Torch

There is a corresponding relationship between MOT item and the ordering code. When one bit of
the ordering code is chosen, the corresponding MOT item will be highlighted. When one MOT
item is chosen, the corresponding bit of ordering code will be highlighted.

Click the button "Default", all options will be chosen as default value directly. Click the button
"Import Excel" or "Import Code", an existing MOT file (*.xls) or an MOT code can be directly
imported into the corresponding device type of PCS-Torch.

2.6 Ordering Code

The ordering code of a MOT consists of 9 parts, including:

 Device type: indicates the device type

 U field: indicates application scenario

 A field: indicates firmware type, which can be standard version or regional version

 R field: indicates firmware version

 S field: indicates software functions

PCS-9671S Transformer Relay 2-7


Date: 2021-06-30
2 Guide of PCS-Torch

 C field: indicates chassis structure and installation

 PWR field: indicates the voltage level of power supply plug-in module

 H field: indicates plug-in module configuration

 MOT version: indicates MOT version

2 The display format is shown as below:

MOT version
H field
PWR field
C field
S field
R field
A field
U field
Device type

2.7 Export MOT

After finishing MOT (Market Ordering Table) configuration, click the button “Complete” to display
the currently selected configuration information, including the ordering code and the device′s
hardware configuration, is shown as below:

Button Remark

Copy ordering code based on selected information to the clipboard

Display device′s rear view based on selected information

2-8 PCS-9671S Transformer Relay


Date: 2021-06-30
2 Guide of PCS-Torch

Export MOT (Market Ordering Table) and device′s hardware configuration in Excel file format

Close the current window

Both MOT and device′s hardware configuration can be exported in Excel file format, as shown in
figures below.

 Exported MOT
2

 Exported device′s hardware configuration

After finishing MOT configuration, the rear view of the device based on selected information can
be displayed. The device′s hardware configuration is displayed graphically (including Slot No.,
Module ID, and total slot numbers), as shown in the figure below.

PCS-9671S Transformer Relay 2-9


Date: 2021-06-30
2 Guide of PCS-Torch

2.8 MOT Library Management

The latest MOT library is included when PCS-Torch is released. The MOT library contains MOT
templates of each device, which are stored in the directory according to the device type. Each
directory contains all historical versions of the device for the MOT template. The path of MOT

library is "installation directory→PCS-Torch→motLib". There are two methods to upgrade the MOT

library. Please select one from the menu bar “Edit”.

1. Update the MOT library online

Firstly, PCS-Torch reads a list of MOT templates for all devices from the server, and compares
them with local MOT library. The user can select the MOT template that needs to be updated, and
PCS-Torch downloads the corresponding MOT template file from the server.

2-10 PCS-9671S Transformer Relay


Date: 2021-06-30
2 Guide of PCS-Torch

2. Import the MOT library locally

It takes a long time to update the MOT library by connecting to the server, and the user can
directly import the latest MOT library if the network conditions are not good (The latest MOT
template library can be gained by mail firstly).

PCS-9671S Transformer Relay 2-11


Date: 2021-06-30
3 MOT Information

3 MOT Information

Table of Contents

3.1 Device Type ...................................................................................................... 3-1


3.2 Application Scenario (U Field) ........................................................................ 3-1
3.3 Firmware Type (A Field) .................................................................................. 3-1
3.4 Firmware Version (R Field) ............................................................................. 3-1 3
3.5 Software Functions (S Field) .......................................................................... 3-1
3.5.1 Software .............................................................................................................................3-1

3.5.2 Language............................................................................................................................3-2

3.5.3 Protocol ..............................................................................................................................3-2

3.5.4 Sampling Mode ...................................................................................................................3-2

3.6 Chassis Structure and Installation (C Field) ................................................. 3-2


3.6.1 Case Size ...........................................................................................................................3-2

3.6.2 Installation Mode ................................................................................................................3-3

3.6.3 Front Side Protection Class ................................................................................................3-8

3.6.4 Harsh Environment Conformal Coating ..............................................................................3-8

3.6.5 I/O Terminal ........................................................................................................................3-9

3.7 Power Supply for Device (PWR Field)............................................................ 3-9


3.8 Plug-in Module Configuration (H Field) ......................................................... 3-9
3.8.1 Communication Ports & Time Synchronization Mode .......................................................3-10

3.8.2 PRP/HSR..........................................................................................................................3-10

3.8.3 Slot02 ............................................................................................................................... 3-11

3.8.4 Slot03 ............................................................................................................................... 3-11

3.8.5 Slot04 ............................................................................................................................... 3-11

3.9 MOT Version ................................................................................................... 3-13

PCS-9671S Transformer Relay 3-a


Date: 2021-06-30
3 MOT Information

3-b PCS-9671S Transformer Relay


Date: 2021-06-30
3 MOT Information

3.1 Device Type


For a specific device, the device type is fixed, such as PCS-9671S, so it is not need to be chosen.

3.2 Application Scenario (U Field)


The corresponding application scenarios are selected according to the actual protected objects by
the device, such as “A-Transformer”, “B-Reactor”.

3.3 Firmware Type (A Field)


The firmware type is used to select between the standard version program and the regional 3
version program. Only the standard version program is available, so it is chosen as "Standard"
fixedly.

3.4 Firmware Version (R Field)


The firmware version is used to select required program version. If there is no special version
requirement, the latest version can be chosen, i.e., “Latest version”. Otherwise, the specified
version can be chosen.

3.5 Software Functions (S Field)


The software functions are determined by four parts: "Software", "Language", "Protocol" and
"Sampling mode".

3.5.1 Software
The option is used to select the required protection functions, which is used in conjunction with the
application scenario option. Different options correspond with different combinations of protection
functions, which can be viewed through the button "Software Functions" in PCS-Torch.

PCS-9671S Transformer Relay 3-1


Date: 2021-06-30
3 MOT Information

3.5.2 Language

The option is used to select other supported language. "Chinese" is supported fixedly. "English",
"English + French", "English + Russian" or "English + Spanish" is available.

3.5.3 Protocol
The option is used to select the supported protocol for communication with SCADA system. There
are several kinds of protocols, including IEC103, DNP3.0, Modbus and IEC61850.

"Basic (IEC 60870-5-103 + DNP3.0 + Modbus)": includes IEC 60870-5-103, DNP3.0 and
Modbus.

"Basic + IEC 61850 (Edition 1.0 or Edition 2.0)": includes IEC 60870-5-103, DNP3.0, Modbus
and IEC 61850, and full compatibility between IEC 61850 Edition 1.0 and 2.0.

3.5.4 Sampling Mode


The option is used to select sampling mode, only one kind of sampling mode is available, so it is
chosen as "Conventional instrument transformer" (conventional sampling mode).

3.6 Chassis Structure and Installation (C Field)


The chassis structure and installation are determined by five parts: "Case Size", "Installation
Mode", "Front Side Protection Class", "Harsh Environment Conformal Coating" and "I/O
Terminal".

3.6.1 Case Size

The option is used to select the case size. The device supports one of case size: "6U 1/3 19" (6U

3-2 PCS-9671S Transformer Relay


Date: 2021-06-30
3 MOT Information

height, 1/3 width, 19-inch chassis).

The 6U 1/3 chassis supports 15 configurable LEDs, and it provides 3 slots (Slot2~Slot4) for
analogue input (AI) module and extended input/output (I/O) modules, the CPU module is fixed at
slot 1, and the power supply (PWR) module is fixed at slot P1.

The panels of 1/3 chassis are as below:

3.6.2 Installation Mode


The device supports 5 installation modes. This option is used to select the desired installation
mode, so that the manufacturer can provide the corresponding installation accessories.

"Flush": flush mounting

"Semi-flush": semi-flush mounting

"Rack": rack mounting

"Wall": wall mounting

"Surface": surface mounting

When the installation mode chooses "Rack", please communicate with the
manufacturer to confirm the different installation accessories.

PCS-9671S Transformer Relay 3-3


Date: 2021-06-30
3 MOT Information

1. Flush Mounting

2. Semi-flush Mounting

3-4 PCS-9671S Transformer Relay


Date: 2021-06-30
3 MOT Information

3. Rack Mounting

1) Single 6U, 1/3 * 19''

PCS-9671S Transformer Relay 3-5


Date: 2021-06-30
3 MOT Information

2) Dual 6U, 1/3 * 19'', side-by-side

3-6 PCS-9671S Transformer Relay


Date: 2021-06-30
3 MOT Information

4. Wall Mounting

5. Surface Mounting

1) Front side protection class: IP52

PCS-9671S Transformer Relay 3-7


Date: 2021-06-30
3 MOT Information

2) Front side protection class: IP54

3.6.3 Front Side Protection Class


There are two kinds of protection classes for the front side of the device: IP52 and IP54. If the
protection class is selected as IP54, the manufacturer will provide the corresponding accessories.

This option is related to “Installation Mode”. When the installation mode


chooses "Surface", the front side of the device can support two kinds of
protection class (IP52 and IP54). For other installation modes, only IP52 is
supported, and "Front Side Protection Class" will be always fixed as
"IP52".

3.6.4 Harsh Environment Conformal Coating


For some harsh operating conditions, such as petrochemical project (chemical plant, refinery),
underground project (metro, underground pipe gallery, coal mine), coastal areas (such as Hong
Kong, offshore wind power), high-humidity-hot areas (such as Southeast Asia, Africa), the device
is often in the windy, dusty or hot-and-humid environment, there are risks such as short circuit,
corrosion, module damage, etc., so the harsh environment conformal coating treatment is often
needed to provide protection against extreme moisture, corrosive gases, aggressive dust, etc.

The option is used to select whether or not the harsh environment conformal coating treatment is
needed. If "Required" is selected, the harsh environment conformal coating treatment for the
whole device will be done before delivery.

3-8 PCS-9671S Transformer Relay


Date: 2021-06-30
3 MOT Information

3.6.5 I/O Terminal


The option is used to select the I/O terminal type, including the binary input, binary output and
device power supply terminals. The device supports three types of I/O terminal:

 "0.8~4mm2 lead (26-pin connector, ring ferrule, IP10)": 0.8~4mm2 lead, 26-pin screw
terminal with protection class IP10

 "0.8~4mm2 lead (26-pin connector, ring ferrule, IP20)": 0.8~4mm2 lead, 26-pin screw
terminal with protection class IP20

 "0.8~2.5mm2 lead (36-pin connector, pin ferrule, IP20)": 0.8~2.5mm2 lead, 36-pin (two
18-pin) screw terminal with protection class IP20 3
The appearance of the terminals are as below.

IP10 (0.8~4mm 2) IP20 (0.8~4mm 2)

IP20 (0.8~2.5mm2)

3.7 Power Supply for Device (PWR Field)


This option is used to select the voltage level of the power supply of the device.

The power supply module supports external power supply input of 110Vdc~250Vdc /
100Vac~250Vac or 24Vdc~60Vdc, and provides 9 binary inputs and 6 binary outputs (5NO+1NC,
NC contact is output contact of the device failure).

3.8 Plug-in Module Configuration (H Field)


The plug-in module configuration is used to select hardware resources, such as the number of

PCS-9671S Transformer Relay 3-9


Date: 2021-06-30
3 MOT Information

communication ports, the number of binary inputs and outputs, the number of AC analogs, and so
on. Different case size can support different hardware resources.

3.8.1 Communication Ports & Time Synchronization Mode


The option is used to select the number and type of communication ports and time
synchronization mode.

 "2 × 10Base-T/100Base-TX (RJ45) + 2 × RS-485 + RS-485 (IRIG-B or PPS)": 2 RJ45


Ethernet ports for Ethernet communication, 2 RS-485 serial ports for communicating with
SCADA system, 1 RS-485 serial port for clock synchronization (IRIG-B or PPS).

3  "4 × 10Base-T/100Base-TX (RJ45) + 2 × RS-485 + RS-485 (IRIG-B or PPS)": 4 RJ45


Ethernet ports for Ethernet communication, 2 RS-485 serial ports for communicating with
SCADA system, 1 RS-485 serial port for clock synchronization (IRIG-B or PPS).

 "2 × 10Base-T/100Base-TX (RJ45) + 2 × 100Base-FX (LC-Connector) + 2 × RS-485 +


RS-485 (IRIG-B or PPS)": 2 RJ45 Ethernet ports for Ethernet communication, 2 optical fibre
ports for Ethernet communication (LC type), 2 RS-485 serial ports for communicating with
SCADA system, 1 RS-485 serial port for clock synchronization (IRIG-B or PPS).

 "4 × 100Base-FX (LC-Connector) + ST-Connector (IRIG-B or PPS)": 4 optical fibre ports


for Ethernet communication (LC type), 1 optical fibre port for clock synchronization
(ST-connector, IRIG-B or PPS).

 "2 × 10Base-T/100Base-TX (RJ45) + 2 × RS-485 + BNC": 2 RJ45 Ethernet ports for


Ethernet communication, 2 RS-485 serial ports for communicating with SCADA system, 1
BNC port for clock synchronization (IRIG-B or PPS).

 "4 × 10Base-T/100Base-TX (RJ45) + 2 × RS-485 + BNC": 4 RJ45 Ethernet ports for


Ethernet communication, 2 RS-485 serial ports for communicating with SCADA system, 1
BNC port for clock synchronization (IRIG-B or PPS).

 "2 × 10Base-T/100Base-TX (RJ45) + 2 × 100Base-FX (LC-Connector) + 2 × RS-485 +


BNC": 2 RJ45 Ethernet ports for Ethernet communication, 2 optical fibre ports for Ethernet
communication (LC type), 2 RS-485 serial ports for communicating with SCADA system, 1
BNC port for clock synchronization (IRIG-B or PPS).

3.8.2 PRP/HSR
The option is used to determine whether or not PRP/HSR networking mode is supported.

The module type in slot No.01 is determined by the two options,


"Communication Ports & Time Synchronization Mode" and
"PRP/HSR".

3-10 PCS-9671S Transformer Relay


Date: 2021-06-30
3 MOT Information

3.8.3 Slot02

The option is used to select the I/O module located in slot No.2, and is chosen as "12CT (1A/5A)"
fixedly, meaning 12 AC current inputs, the secondary rated current is adaptive between 1A and
5A.

3.8.4 Slot03

Currently, the option is used as reserved bit and it is chosen as "Not required" fixedly.

3.8.5 Slot04
This option is used to select the extended I/O module located in slot No.4.
3
 "Not required": the extended I/O module located in slot No.4 is not required.

 "25 BI (Common negative supply)": 25 binary inputs share the common negative input of
power supply, and the rated voltage of binary input can be 24Vdc, 48Vdc, 110Vdc, 125Vdc,
220Vdc, 250Vdc, 110Vac or 220Vac, which can be set through the settings.

 "13 BO (Normal, NO)":13 normal binary outputs, normally open contact (NO).

 "13 BO (Normal, 11 NO + 2 NC)":13 normal binary outputs, 11 normally open contacts (NO)
and 2 normally closed contacts (NC).

 "4 BO (Heavy-capacity, NO) + 4 BO (Normal, NO)": 4 large-capacitor binary outputs (its


breaking capacity is 10A), normally open contact, and 4 normal binary outputs, normally open
contact.

 "13 BI (Independent negative supply, settable conducting mode by high power with
constant current drain)": 13 binary inputs with independent negative supply terminals and
the rated voltage of binary input can be 24Vdc, 48Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc,
110Vac or 220Vac, which can be set through the settings. The conducting mode by high
power with constant current drain of binary inputs could be enabled by setting. The
instantaneous active power rises along with the voltage during such mode, so as to avoid
mistaken signal.

 "32 BI (2 groups, each group share 1 common negative supply)": 32 binary inputs with
two 18-pin connectors, BI01~BI16 share one common negative input of power supply and
BI17~BI32 share another common negative input of power supply.

 "17 BO (Normal, 15 NO + 2 NC/NO)": 17 normal binary outputs, the first 15 BOs are normally
open contact. The last 2 BOs are normally closed/open contacts, and each BO has 3
terminals, and the normally open contact and normally closed contact share one common
terminal.

 "16 BI (Common negative supply) + 8 NO (Normal, 6 NO + 2 NC/NO)": 16 binary inputs on


the upper rank of 18-pin connector share one common negative input of power supply; 8
normal binary outputs on the lower 18-pin connector, the first 6 BOs are normally open
contacts; The last 2 BOs are normally closed/open contacts, and each BO has 3 terminals,
and the normally open contact and normally closed contact share one common terminal.

PCS-9671S Transformer Relay 3-11


Date: 2021-06-30
3 MOT Information

 "4 configurable DC analog outputs (4~20mA, 0~10V, 0~5V, 0~20mA)": 4 configurable DC


analog outputs, 4~20mA, 0~10V, 0~5V, 0~20mA.

 "12 configurable transducer inputs (0~±20mA, 0~±10V)": 12 configurable transducer


inputs, 0~±20mA or 0~±10V.

 "14 BI (Independent negative supply, settable conducting mode by high power with
constant current drain)": 14 binary inputs with independent negative supply terminals and
the rated voltage of binary input can be 24Vdc, 48Vdc, 110Vdc, 125Vdc, 220Vdc, 250Vdc,
110Vac or 220Vac, which can be set through the settings. The conducting mode by high
power with constant current drain of binary inputs could be enabled by setting. The

3 instantaneous active power rises along with the voltage during such mode, so as to avoid
mistaken signal.

Option "Slot04" is related to "I/O Terminal".

1. When "I/O Terminal" is chosen as "0.8~4mm2 lead (26-pin


connector, ring ferrule, IP10)" or "0.8~4mm2 lead (26-pin connector,
ring ferrule, IP20)", the following items can be activated,

 "25 BI (Common negative supply)"

 "13 BO (Normal, NO)"

 "13 BO (Normal, 11 NO + 2NC)"

 "4 BO (Heavy-capacity, NO) + 4 BO (Normal, NO)"

 "13 BI (Independent negative supply, settable conducting


mode by high power with constant current drain)"

2. When "I/O Terminal" is chosen as "0.8~2.5mm2 lead (36-pin


connector, pin ferrule, IP20)", the following items can be activated,

 "32 BI (2 groups, each group share 1 common negative


supply)",

 "17 BO (Normal, 15 NO + 2 NC/NO)",

 "16 BI (Common negative supply) + 8 NO (Normal, 6 NO + 2


NC/NO)"

 "4 BO (Heavy-capacity, NO) + 4 BO (Normal, NO)"

 "4 configurable DC analog outputs (4~20mA, 0~10V, 0~5V,


0~20mA)"

 "12 configurable transducer inputs (0~±20mA, 0~±10V)"

 "14 BI (Independent negative supply, settable conducting

3-12 PCS-9671S Transformer Relay


Date: 2021-06-30
3 MOT Information

mode by high power with constant current drain)"

3.9 MOT Version


It indicates the version of MOT. For different versions, the corresponding options may be different.

PCS-9671S Transformer Relay 3-13


Date: 2021-06-30
3 MOT Information

3-14 PCS-9671S Transformer Relay


Date: 2021-06-30