Govt. Regd. No. NSIC/SL /GP/RS/RfG N/WB/T-01I /l I
NABL ACCREDITED MAK A RDAH ROA D, SHAN PUR tCH ATTERJEE SHED) C etlilicale N ‹o DA SN AGAR, HOWRAH - 7 I I I 0'i
TEST RESORT TIDL/TEST /04
Page No . ” of 1 Test Report No. ] ULR-TC524018 I 00000072F Date : o6 10/2018 Mls. H. SARKER & COMPANY VALVES (P) LTD Customer‘s Name & Address (Formerly Known as H. SARKER & CO.) Your Ref. : Balitikuri, Bakultala, Dasnagar, Howrah - 711113. HS/IDTL/10/18 Dt. 03-10-2018. Description of Sample 01 No. Grey C.I. Test Bar for Mechanical Test. Identification Mark Mark No. BS/]A-1-18.
Environmental Condition : Ambient
The tests marked with an ° ara not accredited by NABL This is to certify that the above sample (s) has been tested with the following results
MECHANICAL FINDINGS REQUIRED VALUES OF
BS 1452/1990, Grade - 220
U. T. S. 232 N/mm* 220 N/mm* min.
Hardness 197, 201, 197 HBW 160 to 210 HBW
The above results conform to BS 1452/1990, Grade - 220
Specification used - IS:1608/2005 (RA-2010) for Mechanical Test.
IS:1500 (Part-1) 2013. for Brinell Hardness Test
Sample Received on - 03-10-2018.
Test Completed on - 06-10-2018.
ager e Dy Quality Manager
Sample (s) not drawn by us
Result pertains to samples. For The Induatrla opment & Testing Laboratory Ph 2667-1938(How)24711569(Ko1)Fax :(033)2829-7€53.Mob :9836706349, e-mail ghoseanik/gméLcom
Note : The test report shall not be reproduced, except in full, without written approval of the Laboratory