Composite Construction: Mahasiswa Dapat Merencanakan Elemen Komposit
Composite Construction: Mahasiswa Dapat Merencanakan Elemen Komposit
Composite Construction: Mahasiswa Dapat Merencanakan Elemen Komposit
Shear Connector
ELEMEN STRUKTUR LENTUR
DISTRIBUSI TEGANGAN PLASTIS
𝒘 𝒚
fy
Cc = Ts
Cc = Ts a≤t
As f y Mn = ( Cc atau Ts ) y
a
0,85 f c' beff
a>t → Cc + Ts’ = Ts
b eff
Ts = (As-As’) fy
For the determination of the available strength, concrete shall have a compressive
strength, f cc, of not less than 3 ksi (21 MPa) nor more than 10 ksi (69 MPa) for normal
weight concrete and not less than 3 ksi (21 MPa) nor more than 6 ksi (41 MPa) for
lightweight concrete
The specified minimum yield stress of structural steel used in calculating the strength
of composite members shall not exceed 75 ksi (525 MPa).
The specified minimum yield stress of reinforcing bars used in calculating the strength
of composite members shall not exceed 80 ksi (550 MPa).
Effective Flange Width
B eff 1 =¼L
B eff 2 = ½ ( L1 + L2)
L0 L1 L2
Slab on both sides:
Effective Flange Width (Least of the three)
Total width: ¼ of the beam span
Overhang: 8 x slab thickness
Overhang: ½ the clear distance to next