Features and Benefits: Condensing Units Options Air Handlers Offer More Flexibility

You might also like

You are on page 1of 1

Features and

Benefits

Condensing Units Options Trane split systems have been specified Air Handlers Offer More
in thousands of applications and you’ll Flexibility
TheTWA075A and 100A single
find Odyssey will win you even more
compressor models feature single jobs with its small manageable cabinet.
refrigeration circuitry, lowering job Flexibility is a key to meeting changing
This light, compact design will save time market requirements. Odyssey split
installation costs by requiring only one
and money for rigging and installation. sytems offer not only heat pumps but
set of refrigerant lines.These units are And the compactness will permitTrane’s
ideal for the low cost, new construction also convertible air handlers.The air
unit to replace almost any unit — handlers can be installed either vertically
jobs as well as renovation and
effortlessly. in a mechanical room or horizontally
replacement buildings.
Low Ambient Cooling Operation above a ceiling. And it doesn’t require
In addition, Odyssey includesTWA155B any removal of panels to make either
and 200B dual compressor units to give Each heat pump unit can operate to 50°F airflow application work.These air
true stand-by protection; if one (10°C) as standard in the cooling mode. handlers have a double sloped
compressor fails, the second will An accessory Head Pressure Control condensate drain pan that allows for
automatically start-up. Also, the first gives you the capability to operate to 0°F either airflow configuration. And the
compressor can be serviced without (-18°C). All heat pumps offer these drain pan can easily be removed for
shutting down the unit since the accessories: cleaning. All the air handlers feature
refrigerant circuits are independent. • Head Pressure Control factory installed belt drive and ball
• Coil Guard Kits bearing evaporator fans with adjustable
Dual compressors are not just for • Isolators both Rubber-in-Shear and sheaves for maximum airflow
protection, they also save energy costs. SpringType performance. In fact, the standard motor
Most buildings are designed for the peak • Anti-Short-Cycle Kit on theTWA100A air handler will deliver
load requirements yet the building • Time Delay Relay 3325 cfm (5649 m3/hr) at 1.4" (349 Pa)
usually operates at less than peak load. ESP. Plus oversized motors are available
During light load conditions, only one for higher static applications.
compressor functions to maintain the
space comfort thus reducing the need
for energy.

4 SSP-PRC002-EN