GE Oil & Gas

Drilling & Production

Hydril Pressure Control Flexible subsea blowout prevention


Annu-Flex™
Pressure Control Equipment: Blowout preventers

Applications & Benefits


We drew on more than 55 years of BOP application experience
in all BOP types, sizes and pressure ranges when creating the
Hydril Pressure Control Annu-FlexTM. A variation of our GX
annular BOP, drilling contractors’ “best annular in the business,”
the Annu-Flex combines a reliable subsea annular blowout
preventer with a maintenance-free, flexible underwater riser
joint. Together, the BOP head/flex joint combination reduces
overall stack height and requires fewer stack connections.
Additionally, the Annu-Flex offers:
• Rapid and economical maintenance
• Simple and reliable operations
• Long service life

Key Features
Designed specifically for subsea drilling applications, the
Hydril Pressure Control Annu-Flex enhances the best of
our GX annular BOP’s performance and serviceability with
several distinguishing features:
• A flex-joint design eliminates friction that causes binding
and galling as well as the need for lubrication and pressure
compensation commonly found in ball-type designs
• An elastomer element, the key component of the subsea
flexible joint, is permanently bonded to an inner housing
and outer ring
• A guide ring/wear bushing absorbs through-the-bore wear
during normal operations to protect the elastomer element
and the main housing
• A housing/latched head to retain full working pressure rating
The Hydril Pressure Control Annu-Flex
Advantage
Only the Hydril Pressure Control Annu-Flex can offer the
performance and serviceability of our GX annular BOP in a
unit designed specifically for subsea drilling applications. With
its compact design and distinctive flex joint, the Annu-Flex
decreases overall stack height to free up critical space and
require fewer stack connections.

Engineering Data
DUAL SINGLE
Bore (inches) 18.75 18.75
Working Pressure (psi) 10,000 10,000
Hydraulic Operating Pressure (psi) 1,500 1,500
Gal. to Close (U.S. gal.) 58 per BOP 58
Gal. to Open (U.S. gal.) 58 per BOP 58
Stud to flange height (inches) Flanged Bottom 10 m 174.45 116.45
15 m 177.42 119.42
Clearance Diameter (inches) 84.00 84.00
Weight (lbs.) 112,118 65,000

3300 North Sam Houston Parkway East, Houston, TX 77032


24/7 customer support: +1 281 449 2000
geoilandgas.com/drilling

GE imagination at work
© 2010 General Electric Company. All rights reserved.
HY_Annu-Flex_FS_080610
GE Oil & Gas
Drilling & Production

Hydril Pressure Control


Hold pressure at 15,000 psi
Compact™ Ram Blowout from 30 to 500° F
Preventer
Pressure Control Equipment: Blowout Preventers

Applications & Benefits


The 18¾", 15,000 psi Hydril Pressure Control Compact™ • The bonnet seal carrier ring has a pressure-assisted design
ram BOP delivers proven reliability for safe operation in the that enables the BOP to withstand external pressure
harshest environments. Rated for water depths to 15,000+ ft, differentials as high as 7,000 psi, equivalent to a depth of
the Compact ram has worked on the seabed continuously 15,000+ ft; this can occur in deep water in the event of a
for one year during drilling of a 34,000-ft well. It can also large pressure drop in the well bore
add hundreds of hours of drilling time annually when • A single set of high-performance elastomers handles both
configured to seal upside-down as a Subsea Stack Test Valve hot and cold temperature extremes
(SSTV) so that required pressure tests can be completed with • Multiple-position lock uses a reliable, mechanical clutch to
the drill pipe in place. automatically lock the rams in a seal-off position
• Hydraulic manifold increases operating flexibility; it can be
This BOP has:
installed on either side of the BOP with the bonnets opening
• Successfully held full rated working pressure at 300° F for
on the opposite side to fit various stack configurations
eight hours using blind/shear rams; the tested unit then
• Corrosion-resistant alloy is used in ring grooves, bonnet
completed three additional closing cycles at low and high
sealing area, seat bores and piston rod bore seal area for
pressure
long life
• Passed API temperature testing requirements to 350° F
using blind/shear rams
• Passed API temperature tests to 500° F using fixed-bore rams
• All fixed-bore ram sizes on the 18-15 Compact ram are
rated for this temperature
• Passed API pressure tests at temperatures as low as 30° F
for 5½" to 75⁄8" and 4½" to 7" variable rams
• Sheared large-diameter pipe (16", 109 lb-per-ft, P-110) with
closing pressure of 4,000 psi

Key Features
• Field-replaceable upper seal seats, bottom wear plates and
hydraulic manifold virtually eliminate the need to move the
unit to an authorized repair facility for service
The Hydril Pressure Control Compact Ram
Advantage
Since our engineers invented the annular BOP, world leaders Because testing requirements are becoming increasingly
in oil and gas drilling have depended on Hydril Pressure severe, we have upgraded test center capabilities well
Control equipment for reliable performance in applications beyond the HPHT limits sought by the industry today.
with extreme pressures, temperatures and other unusual Current capabilities include:
challenges. • High-temperature testing to 500° F
• Low-temperature testing to -80° F
We push the boundaries of pressure control every day at our
• High-pressure testing to 50,000 psi
state-of-the-art testing facilities. Even when testing pushes
• Shear testing for large-diameter and heavy-wall pipe
Hydril Pressure Control equipment beyond its capabilities,
• Pressure testing with hang-off loads up to 600,000 lbs
we learn what failed, why and how. This knowledge forms
• External Hydrostatic testing to 7,000 psi
a growing base for new and improved products. From it, we
identify new design goals to take pressure control even further.

Engineering Data
Extended Double
Bore (inches) 18.75 18.75 18.75 18.75
Working Pressure (psi) 5,000 10,000 15,000 15,000
Recommended Hydraulic Operating Pressure (psi) 1,500 1,500 1,500 1,500
Gal. to Close (U.S. gal.) Operator 22.00" - - 39.3 39.3
Operator 19.00" 29.7 29.7 29.2 29.2
Operator 15.50" - - 19.5 19.5
Operator 14.25" 16.4 16.4 - -
Gal. to Open (U.S. gal.) Operator 22.00" - - 36.6 36.6
Operator 19.00" 28.1 28.1 26.5 26.5
Operator 15.50" - - 16.8 16.8
Operator 14.25" 14.9 14.9 - -
Closing Ratio Operator 22.00" - - 14:64:1 14:64:1
Operator 19.00" 18:9:1 18:9:1 10:49:1 10:49:1
Operator 15.50" - - 7:27:1 7:27:1
Operator 14.25" 10:6:1 10:6:1 - -
Stud to Flange Height (inches) 59.00 63.00 75.00 60.00
Stud to Flange Weight (pounds) 34,000 35,000 53,100 31,000
Length (inches) 142.50 142.50 146.60 146.60

Note: all dimensions refer to double/dual rams

3300 North Sam Houston Parkway East, Houston, TX 77032


24/7 customer support: +1 281 449 2000
geoilandgas.com/drilling

GE imagination at work
© 2010 General Electric Company. All rights reserved.
GE_HY_CRBOP_FS_080610
GE Oil & Gas
Drilling & Production

Hydril Pressure Control


For lower maintenance and more
GK® Annular Blowout uptime in surface applications
Preventer
Pressure Control Equipment: Blowout Preventers

Applications & Benefits


• A bolted-in inner sleeve that eliminates the need for weld
The Hydril Pressure Control GK® annular blowout preventer’s repair and is field-replaceable
field-tested and proven design has provided world-class • A replaceable wear plate that eliminates metal-to-metal
dependability and quality in surface applications for over 50 contact between the packing unit inserts and the BOP
years. head, extending time between major overhaul and repair
• A long piston design for complete balance and more
We test every GK’s operating chambers to full working pressure
reliable operation as well as ease of assembly
to ensure strength, reliability and the ability to over-pressurize
• Engineered elastomer compounds which are carefully
the chambers in emergencies. The GK provides quick, positive
developed, designed, manufactured and tested by
closing action with simplified controls to keep drilling fluids in
GE Oil & Gas chemists
the hole when a blowout threatens. The packing unit permits
closure on drill pipe, kelly, tool joints or tubing, and wireline
as well as the open hole.
• Easy precharge and maintainance – charging assemblies
are included free with every purchase
• Outstanding durability with standard hydrogenated nitrile
elastomer
• At-a-glance precharge and bladder verification with sight
glass option
• Reduced downtime with field-replaceable diaphragms

Key Features
The GK makes maintenance easy and lengthens the time
between packing unit changes and shop repairs. The key to
these benefits is a simple design that includes:
• A single packing unit that closes on any size pipe or open
hole – and handles stripping
• Only two moving parts: the piston and packing unit, for
less wear and maintenance
• An optional latched head for fast, easy access to the
packing unit and wear seals; the majority of GK annulars
have a screwed head design
The Hydril Pressure Control GK Advantage
The packing unit for the GK annular BOP can hold full-rated When the GK closes, the piston moves up, driving the
working pressure and will close on an open hole. Before elastomer and inserts inward where they quickly reach a
shipment, each packing unit is factory tested in a BOP – to fixed position and form a steel ring that prevents the rubber
50% of working pressure on open hole and 100% on pipe. from moving upward under wellbore pressure. After the ring
The GK provides longer life when using genuine Hydril is formed, feedable elastomer continues to flow inward around
Pressure Control packing units, as shown in repeated testing. the inserts to create a positive seal on the drill string or open
hole. Because the elastomer is primarily in compression, it
resists tears, cuts and abrasions.

Engineering Data
Bore (inches) 7.0625 7.0625 7.0625 7.0625 7.0625 9.00 9.00 9.00 11.00 11.00
Working Pressure (psi) 3,000 5,000 10,000 15,000 20,000 3,000 5,000 10,000 3,000 5,000
Head Type Screwed Screwed Screwed Screwed Screwed Screwed Screwed Screwed Screwed Screwed
Hydraulic Operating Pressure (psi) 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500
Gal. to Close (U.S. gal.) 2.85 3.86 9.42 11.2 10.9 4.33 6.84 15.9 7.43 9.81
Gal. to Open (U.S. gal.) 2.24 3.3 7.08 7.5 7.2 3.41 5.8 11.95 5.54 7.98
Stud to Flange Height (inches) Flanged Rated 32.00 36.88 48.13 54.13 59.00 37.88 41.75 55.75 39.75 47.81
Bottom
5m - 36.88 - - - - 41.75 - - 47.81
10 m - - 48.13 - - - - 55.75 - 48.56
15 m - - 48.75 54.13 - - - - - -
Stud to Flange Weight (pounds) Flanged Rated 2,715 4,000 12,200 14,250 23,000 3,500 6,000 18,540 5,500 8,200
Bottom
5m - 4,000 - - - - 6,000 - - 8,200
10 m - - 12,200 - - - - 18,540 - -
15 m - - - 14,250 - - - - - -
Clearance Diameter (inches) 32.25 35.75 49.50 61.00 58.00 34.50 41.00 56.75 40.00 44.25

Bore (inches) 11.00 11.00 11.00 13.625 13.625 13.625 13.625 13.625 16.75 16.75
Working Pressure (psi) 5,000 10,000 10,000 3,000 3,000 5,000 5,000 10,000 5,000 5,000
Head Type Latched Screwed Latched Screwed Latched Screwed Latched Latched Screwed Latched
Hydraulic Operating Pressure (psi) 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500
Gal. to Close (U.S. gal.) 9.81 25.1 25.1 11.36 11.36 17.98 17.98 37.18 28.7 28.7
Gal. to Open (U.S. gal.) 7.98 18.97 18.97 8.94 8.94 14.16 14.16 12.59 19.93 19.93
Stud to Flange Height (inches) Flanged Rated 48.25 63.50 63.38 45.25 45.25 54.13 54.50 71.31 61.25 61.30
Bottom
5m 48.25 - - - - 54.13 54.50 - 61.25 61.30
10 m 49.00 63.50 63.38 - - 56.18 59.44 71.31 - -
15 m - 65.81 - - - - - - - -
Stud to Flange Weight (pounds) Flanged Rated - 26,140 - 8,784 - 13,800 13,250 - 20,835 21,230
Bottom
5m - - - - - 13,800 13,250 - 20,835 21,230
10 m - 26,140 - - - 14,500 13,900 - - -
15 m - - - - - - - - - -
Clearance Diameter (inches) 44.25 61.50 60.75 47.50 47.50 52.25 52.25 68.13 59.50 59.50

3300 North Sam Houston Parkway East, Houston, TX 77032


24/7 customer support: +1 281 449 2000
geoilandgas.com/drilling

GE imagination at work
© 2010 General Electric Company. All rights reserved.
HY_GKBOP_FS_080610
GE Oil & Gas
Drilling & Production

Hydril Pressure Control


Field-proven, long-life
GL® Annular Blowout blowout prevention
Preventer
Pressure Control Equipment: Blowout Preventers

Applications & Benefits


The Hydril Pressure Control GL® annular BOP has a field-tested, • A bolted-in inner sleeve that eliminates the need for
field-proven design. It has demonstrated world-class weld repair and is field replaceable
dependability and quality to users for over 30 years. As with • Corrosion-resistant alloy for the ring grooves
all our BOPs, we test every GL’s operating chambers and • SermaGuard™ coating on all internal surfaces
packing unit to full BOP working pressure to ensure strength, • Packing units with nitrile or natural compounds
reliability, and the ability to over-pressurize the chambers • Off-the-shelf deliveries of packing units for minimal lead time
in emergencies. Special and proven features like these are
the reason why customers have come to expect reliable
performance, closure after closure.

Key Features
The key to the GL’s excellent performance lies in its unique
design, which includes:
• A Hydril Pressure Control packing unit that is specially
molded with two different styles of inserts to reduce closing
volume and increase closing cycles
• A replaceable wear plate that eliminates metal-to-metal
contact between the packing unit inserts and the BOP head
• A piston design that provides complete balance, more
reliable operation and ease of assembly
• A latched head for fast, easy access to the packing unit
and wear seals
• An opening chamber head that prevents debris from falling
into the chambers when replacing the packing unit
The Hydril Pressure Control GL Advantage
The GL’s Long Life (LL) Packing Unit has been specifically
designed and tested to provide unsurpassed performance
and durability. In performance tests, it outlasted other
replacement units by a minimum of 5-to-1. The key to this
remarkable performance is a revolutionary asymmetrical
insert design which provides longer life and reliability. The
LL Packing Unit is designed to provide greater fatigue life
without compromising stripping performance and operating
characteristics.

No matter what type of severe service awaits your BOPs,


expect more from the genuine Hydril Pressure Control GL.

Engineering Data
Bore (inches) 18.75 Dual 18.75 21.25
Working Pressure (psi) 5,000 5,000 5,000
Hydraulic Operating Pressure (psi) 1,500 1,500 1,500
Gal. to Close (U.S. gal.) 44 44 58
Gal. to Open (U.S. gal.) 44 44 58
Stud to Flange Height (inches) Flanged bottom 5m 65.25 112.00 77.50
10 m - - 84.25
Stud to Flange Weight (lbs) Flanged bottom 5m 35,000 63,100 45,000
10 m - - -
Clearance Diameter (inches) 76.00 76.00 78.25

3300 North Sam Houston Parkway East, Houston, TX 77032


24/7 customer support: +1 281 449 2000
geoilandgas.com/drilling

GE imagination at work
© 2010 General Electric Company. All rights reserved.
GE_HY_GLABOP_FS_080610
GE Oil & Gas
Drilling & Production

Hydril Pressure Control Expect more closures, stripping


GX®Annular Blowout and uptime. One packing unit can
do it all.
Preventer
Pressure Control Equipment: Blowout Preventers

Applications & Benefits


Drilling contractors have called the Hydril Pressure Control GX® • A latched head for fast, easy access to the packing unit
“the best annular in the business” for one reason: exceptional and wear seals
uptime. Its single packing unit has provided continuous service • A replaceable wear plate that eliminates metal-to-metal
for as long as a year, and it has continued to hold pressure contact between the packing unit inserts and the BOP head
after exposure to extreme temperatures and extensive stripping. • A pressure balanced piston design that allows use in ultra
The GX can strip and seal on all pipe sizes and achieve complete deep water
shutoff. In the field and in laboratory tests, GX units have:
• Passed an ABS-witnessed, 10,000-psi API pressure test at
270° F (132° C)
• Stripped more than 30,000 ft of 65⁄8" drill pipe with 8¼"
tool joints
• Stripped 300,000 ft of 5" drill pipe with 63⁄8" tool joints
before failure
• Held pressure in the field after 328 closing cycles plus stripping

Key Features
Well suited for surface and subsea operations, the GX makes
maintenance easy and lengthens the time between packing
unit changes and shop repairs. The key to these benefits is a
simple design that includes:
• A single packing unit that closes on any size pipe or an
open hole – and handles stripping
• Only two moving parts, the piston and packing unit, for
less wear and maintenance
The Hydril Pressure Control GX Advantage
The packing unit for the GX annular BOP can hold full-rated a positive seal on the drill string or open hole. Because the
working pressure after more closing cycles and stripping elastomer is primarily in compression, it resists tears, cuts
than any other unit available. The GX produces extra uptime and abrasions.
from a significantly larger reservoir of engineered elastomer,
When stripping, the steel inserts again remain fixed. As
and a BOP design that precisely controls the position of
various diameters of pipe and tool joints pass through the
unique, flanged steel inserts.
closed unit, the elastomer flows in and out. Even at higher
When the GX closes, the packing unit rubber drives the inserts wellbore pressures, the GX packing unit maintains precise
inward, where they quickly reach a fixed position and form a control of seal-off tightness to permit a slight leak of drilling
steel ring that prevents the elastomer from extruding upward fluid that provides lubrication, optimizes pull-through forces
under wellbore pressure. After the ring is formed, feedable and further prolongs packer life.
elastomer continues to flow inward around the inserts to create
No matter what type of severe service awaits your BOPs,
expect more from the genuine Hydril Pressure Contol GX.

Engineering Data
Bore (inches) 11.00 11.00 13.625 13.625 18.75
Working Pressure (psi) 10,000 15,000 5,000 10,000 10,000
Hydraulic Operating Pressure (psi) 1,500 1,500 1,500 1,500 1,500
Gal. to Close (U.S. gal.) 17.9 24.1 15.5 24.1 58
Gal. to Open (U.S. gal.) 17.9 24.1 15.5 24.1 58
Stud to Flange Height (inches) Flanged bottom 5m - - 52.32 - -
10 m 57.12 - 54.31
15 m 59.44 - - 65.38 82.50
Stud to Flange Weight (pounds) Flanged bottom 5m - - - - -
10 m 21,385 - - 28,000 52,250
15 m 22,085 - - 28,885 54,360
Clearance Diameter (inches) 60.38 67.12 58.00 64.50 84.00

3300 North Sam Houston Parkway East, Houston, TX 77032


24/7 customer support: +1 281 449 2000
geoilandgas.com/drilling

GE imagination at work
© 2010 General Electric Company. All rights reserved.
GE_HY_GXABOP_FS_080910
GE Oil & Gas
Drilling & Production

Hydril Pressure Control Smooth performance


IP Pulsation Dampener in corrosive environments

Pressure Control Equipment: Pulsation Dampeners

Applications & Benefits


Hydril Pressure Control IP pulsation dampeners extend the
life and increase the efficiency of suction, discharge and
hydraulic flow system lines. Built for industrial and production
applications, the non-wetted shell design reduces maintenance
requirements while accommodating corrosive process liquids.
Flexible and reliable, our dampeners/accumulators:
• Prolong the life of pump valves, fluid cylinders, system
instrumentation, pipe and fittings by moderating pulsations
on the discharge side of reciprocating pumps
• Facilitate acceleration head loss recovery on the suction
side of reciprocating pumps
• Prevent “water hammer” damage by minimizing pressure
surges.
• Arrest thermal expansion by absorbing additional fluid volume
• Protect rotating machinery and lube oil systems by
supplying hydraulic fluid over short intervals during pump
or power failure

Key Features
Hydril Pressure Control IP dampeners are compact, easy to
handle and install, and generally do not require external
support. With an isolated body cavity that confines process
fluid to an elastomeric bladder, the IP features a cost-effective
carbon steel shell and a field-replaceable bottom plate– the
only wetted shell material. Superior corrosion resistance
means IPs are especially well suited for corrosive applications
including waste disposal, salt water injection, and use with
acidic and caustic substances. Additional features include:
• Capacities from 0.5 to 20 gallons
• Elastomeric bladders for a variety of applications
• Customized bottom connections and bottom plate materials
for use with most process liquids
The Hydril Pressure Control IP Advantage
Offering outstanding performance and a wide range of production operations. Combining efficiency and reliability
compatibility options, Hydril Pressure Control IP dampeners/ with superior corrosion resistance, these are the dampeners
accumulators were designed specifically for industrial and of choice for surge absorption, thermal expansion and
hydraulic accumulator applications.
Engineering Data
275 PSI Pressure Rating
Dimensions (inches)
Capacity (Gal) Model No. Width Shell Height Overall Height Weight (lbs)
½ See Note
1 IP-1-275 10.50 10.00 16.25 70
2½ IP-2½-275 12.75 11.50 17.50 85
5 IP-5-275 16.25 14.50 20.625 130
10 See Note
20 SS-20-275 24.00 20.75 27.00 450

NOTE: For 10-gallon units, use IP-10-1440 with ANSI 150 connections. For 1/2-gallon units, use IP-1/2-3600 with ANSI 150 connections.

1,440 PSI Pressure Rating


Dimensions (inches)
Capacity (Gal) Model No. Width Shell Height Overall Height Weight (lbs)
½ See Note
1 IP-1-1440 10.50 10.25 16.50 75
2½ IP-2½-1440 14.25 13.00 18.50 220
5 IP-5-1440 17.50 16.25 22.50 310
10 IP-10-1440 20.25 20.125 25.00 410

NOTE: For 1/2-gallon unit, use IP-1/2-3600 with ANSI 600 connections.

3,600 PSI Pressure Rating


Dimensions (inches)
Capacity (Gal) Model No. Width Shell Height Overall Height Weight (lbs)
½ IP-½-3600 8.25 9.00 14.00 60
1 IP-1-3600 11.25 11.00 17.00 165
2½ IP-2½-3600 14.25 13.75 19.50 220
5 IP-5-3600 17.50 16.50 22.625 305
10 IP-10-3600 21.375 21.25 27.50 708

6,000 PSI Pressure Rating


Dimensions (inches)
Capacity (Gal) Model No. Width Shell Height Overall Height Weight (lbs)
1 IP-1-6000 12.625 12.75 19.00 200
2½ IP-2 ½-6000 15.625 15.25 21.50 330
5 IP-5-6000 20.00 17.50 23.75 600

10,000 PSI Pressure Rating


Dimensions (inches)
Capacity (Gal) Model No. Width Shell Height Overall Height Weight (lbs)
2½ IP-2 ½-10000 18.00 16.00 22.50 520
5 IP-5-10000 22.50 19.625 26.00 1160

3300 North Sam Houston Parkway East, Houston, TX 77032


24/7 customer support: +1 281 449 2000
geoilandgas.com/drilling

GE imagination at work
© 2010 General Electric Company. All rights reserved.
HY_IPDampener_FS_080610
GE Oil & Gas
Drilling & Production

Hydril Pressure Control Proven performance in large-volume,


K™ Pulsation Dampeners high-slurry pump applications

Pressure Control Equipment: Pulsation Dampeners

Applications & Benefits


Manufactured to meet the most demanding large-volume,
high-slurry pump applications, Hydril Pressure Control K™
pulsation dampeners offer outstanding performance for
onshore and offshore drilling, airport fueling systems, tank
truck and marine loading racks, fire water systems, sewage
lines and other large-scale pulsation and surge-control
applications. With many ANSI and API connections available
standard, our K dampeners allow for quick installation, long
service life and these additional benefits:
• Easy precharge and maintainance – charging assemblies
are included free with every purchase
• Outstanding durability with standard hydrogenated nitrile
elastomer
• At-a-glance precharge and bladder verification with sight
glass option
• Reduced downtime with field-replaceable diaphragms

Key Features
Introduced more than 50 years ago, Hydril Pressure Control K
accumulators/dampeners have earned their reputation
for dependability and durability. A torispherical body shape
results in smoother flow and longer diaphragm life. A stabilizer
disk enhances reliability. And a field-replaceable bottom
plate eliminates costly shop repairs for greater efficiency
and economy. In addition, all our K units:
• Are available in a variety of capacities, from 10 to 80 gallons
• Meet a variety of specifications – manufactured to DNV, CRN,
CE, ATEX, ABS-CDS and ISO 9001
• Include ASME code stamping standard on most sizes, and
pressure ratings
The Hydril Pressure Control K Advantage
Proven onshore and off, our K pulsation dampeners are highly
effective under the toughest field conditions. All models are
engineered for reliability, long life and ease of operation. By
manufacturing our own elastomers, we also offer unrivaled
quality control as well as proven materials, compatibility and
availability.

Engineering Data
10 (GAL) CAPACITY
Dimensions (inches)
Model No. Width Shell Height Overall Height Weight (lbs)
K10-275 23.00 23.75 31.10 440
K10-1440 23.00 23.75 31.10 440
K10-3000 23.00 23.75 31.10 950
K10-5000 23.00 23.75 31.10 950

20 (GAL) CAPACITY
Dimensions (inches)
Model No. Width Shell Height Overall Height Weight (lbs)
SS-20-275 24.00 20.75 27.00 450
K20-1440 25.10 26.70 34.10 825
K20-3000 28.50 28.15 35.53 2,145
K20-5000 28.50 28.15 35.53 2,145
20-7500 30.50 29.50 37.60 3,150

80 (GAL) CAPACITY
Dimensions (inches)
Model No. Width Shell Height Overall Height Weight (lbs)
K80-275 38.29 37.31 44.69 2,575
K80-720 38.29 37.31 44.69 2,575
K80-1440 38.29 37.31 44.69 2,575
K80-2000 41.50 38.82 46.20 3,150
K80-3000 41.50 38.82 46.20 3,150
K80-3705 41.50 38.82 46.20 3,150

3300 North Sam Houston Parkway East, Houston, TX 77032


24/7 customer support: +1 281 449 2000
geoilandgas.com/drilling

GE imagination at work
© 2010 General Electric Company. All rights reserved.
HY_KPulsDamp_FS_080610
GE Oil & Gas
Drilling & Production

Hydril Pressure Control


Maintenance-free performance
PASAFE™ Pulsation for extreme conditions
Dampener
Pressure Control Equipment: Pulsation Dampeners

Applications & Benefits


Hydril Pressure Control PASAFE™ pulsation dampeners extend
pump life and enhance piping system performance by
controlling pressure and flow pulsations. Virtually maintenance-
free and available in three specialized flow-through designs,
PASAFE discharge dampeners and suction stabilizers are
engineered specifically to handle abrasive, corrosive, high-
temperature and high-pressure fluids in the most extreme
environments.

Hydril Pressure Control R-PASAFE dampeners are ideal for high-


temperature or chemical applications – including industrial and
oil and gas drilling applications – that can cause compatibility
problems with elastomers. The flow-through design of every
C-PASAFE unit effectively reduces flow and acceleration-
induced pulsations in reverse-osmosis applications. S-PASAFE
combination units, with both large liquid volume and gas
volume, are particularly well suited for slurry and mine
dewatering applications.

All PASAFE pulsation dampeners:


• Increase safety and reliability by requiring no gas precharging
• Handle pressure requirements to 15,000 psi without
any reduction of pulsation
• Require no replacement of internal
parts for greater ease of
use and economy
of ownership

C-PASAFE R-PASAFE
Key Features Engineering Data
Hydril Pressure Control PASAFE dampeners are extremely Outside
effective at reducing pulsation created by the stop and start Overall Width Diameter of
Item (inches) Body (inches) Weight (lbs)
motion of reciprocating pumps, as well as the acceleration-
R12-3600 25.00 18.00 310
induced water hammer caused by opening and closing of
R14-3705 33.00 21.00 360
the pump check valve. Their maintenance-free engineering
eliminates the need for internal parts replacement – ever – R24-1480 35.50 24.00 550

and ensures effective, trouble-free performance even under R80-5000 40.00 39.50 2,325

extreme temperatures and pressures. R120-7500 50.00 50.00 9,900


• Manufactured, tested and ‘U’ stamped in accordance with NOTE: R-PASAFEs can be designed with volumes ranging from 1 to 120 gallons and
pressure ratings from 285 to 10,000 PSI.
ASME Boiler and Pressure Vessel Code
• Available in a variety of materials, including carbon steel,
275 PSI Pressure Rating
stainless steel, duplex stainless steel, HDPE and others
• Broad capacity range – from 1 to 600 gallons Connection Length Diameter Weight
Model (inches) (inches)* (inches) (lbs)

The Hydril Pressure Control PASAFE C001-1200SS or AXN 1.00 31.00 4.50 60

Advantage C002-1200SS or AXN 1.50 34.00 4.50 125

C004-1200SS or AXN 2.00 36.50 8.60 195


Our PASAFE pulsation dampeners represent the largest C006-1200SS or AXN 3.00 44.00 8.62 240
selection of maintenance-free units available on the market. C010-1200SS or AXN 6.00 38.50 12.75 450
Engineered with no elastomeric bladders, seals or other C012-1200SS or AXN 4.00 44.00 12.75 400
wearable goods, PASAFE units offer economical, durable and C020-1200SS or AXN 6.00 48.00 16.00 500
trouble-free discharge dampening and suction stabilizing * Length shown for ANSI 600# flange connection. Victaulic connections also available.
for the extreme conditions found in oil well drilling, slurry
pipelines, deep direct lift mine dewatering, chemical 275/285 PSI dampeners
processing, water purification and high-pressure water
cleaning. Connection Length Diameter Weight
Model (inches) (inches)* (inches) (lbs)

C006-0275SS or AXN 3.00 47.75 8.62 190

C012-0275SS or AXN 4.00 36.50 12.00 250

C015-0285SS or AXN 4.00 42.25 14.00 300

C020-0275SS or AXN 6.00 37.5 16.00 400


* Length shown for ANSI 600# flange connection. Victaulic connections also available.

HDPE SUCTION STABILIZERS

Connection Length Diameter Weight


Model (inches) (inches)* (inches) (lbs)

C003-0100HPE 2.00 46.00 7.13 35

C004-0100HPE 3.00 46.00 10.75 45

C006-0100HPE 4.00 46.00 14.00 70

C0012-0100HPE 6.00 50.00 18.00 130

C0020-0100HPE 8.00 59.00 24.00 225

C0020-0100HPE 10.00 59.00 24.00 225


* Length shown for ANSI 600# flange connection. Victaulic connections also available.

3300 North Sam Houston Parkway East, Houston, TX 77032


24/7 customer support: +1 281 449 2000
geoilandgas.com/drilling

GE imagination at work
© 2010 General Electric Company. All rights reserved.
HY_PASAFE_PulsDamp_FS_080910
GE Oil & Gas
Drilling & Production

Hydril Pressure Control


Change rams and resume
Quik-Loq™ Ram drilling fast
Blowout Preventer
Pressure Control Equipment: Blowout Preventers

Applications & Benefits Key Features


Our Hydril Pressure Control Quik-Loq™ is a Boltless™ blowout The Quik-Loq is designed from the inside out to make all
preventer that increases drilling efficiency while maximizing operations easy, fast and safe while increasing uptime.
the safety of field personnel and protection of the environment. Its key enabling features include:
It achieves all these goals by eliminating the need for tools • Boltless bonnets
during ram and operator changeouts. With Quik-Loq, • Tool-free, hydraulic locking and unlocking of the
changeouts are completed 90% faster, in minutes rather operators to the ram body
than hours. Well suited for surface and subsea operations, • Pivots that permit 360° rotation of ram blocks for
this state-of-the-art BOP offers all of the performance of our easy access and service
proven Compact™ ram, and has successfully completed • Redundant, bidirectional wellbore seals
tests including: • Redundant rod seals
• A “mud soaked” drilling environment • 13-10 and 13-15 models that use the same ram blocks
• Life-cycle testing that simulated over a decade of normal • Multiple-position lock that uses a reliable, mechanical
operation clutch to automatically lock the rams in a seal-off position
• Successfully held full rated working pressure at 300° F • A single set of high-performance elastomers to handle
for eight hours using blind/shear rams; the tested unit both hot and cold temperature extremes
then completed three additional closing cycles at low and
high pressure
• Passed API temperature testing requirements
to 350° F using blind/shear rams
• Passed API temperature tests to 500° F
using fixed-bore rams
• Passed API pressure tests at temperatures
as low as 30° F for 5½" to 75⁄8" and 4½" to
7" variable rams
• Sheared large-diameter pipe
(16", 109 lb-per-ft, P-110) with
closing pressure of 4,000 psi
The Hydril Pressure Control Quik-Loq
Advantage
The Quik-Loq’s Boltless tool-free maintenance increases
drilling time and reduces workers’ exposure to hazardous
conditions during BOP maintenance. These enhancements
have been enough to prompt customers to call the Quik-Loq
“the first truly significant improvement in ram-type BOP
design in about 20 years.”

Engineering Data

Bore (inches) 13.625 13.625 18.75


Working Pressure (psi) 10,000 15,000 15,000
Recommended Hydraulic Operating Pressure (psi) 1,500 1,500 1,500
Gal. to Close (U.S. gal.) Operator 14.25" Shear 24.8 24.8 -
Operator 14.25" Standard 13.1 13.1 -
Operator 15.50" - - 19.5
Operator 19.00" - - 29.7
Gal. to Open (U.S. gal.) Operator 14.25" Shear 23.3 23.3 -
Operator 14.25" Standard 11.7 11.7 -
Operator 15.50" - - 16.8
Operator 19.00" - - 28.1
Closing Ratio Operator 14.25" Shear 17:0:1 17:0:1 -
Operator 14.25" Standard 9:0:1 9:0:1 -
Operator 15.50" - - 7:27:1
Operator 19.00" - - 8:22:1
Stud to Flange Height (inches) Flanged Bottom Double 62.07 67.95 75.06
Single 38.57 44.45 46.94
Stud to Flange Weight (pounds) Flanged Bottom Double 29,907 33,800 69,100
Single 16,325 19,041 37,700
Length (inches) Double 136.50 136.50 180.53
Single 136.50 136.50 180.53

3300 North Sam Houston Parkway East, Houston, TX 77032


24/7 customer support: +1 281 449 2000
geoilandgas.com/drilling

GE imagination at work
© 2010 General Electric Company. All rights reserved.
GE_HY_QLRAMBOP_FS_080910
GE Oil & Gas
Drilling & Production

Rams you can rely on


Industry-leading designs for blowout prevention in all
surface and subsea applications
Rams you can rely on
GE Oil & Gas, Drilling & Production provides a full range of Blind shear
industry-leading ram designs for superior performance in Our blind shear rams will completely shut off the well after
our blowout preventers (BOPs) for all surface and subsea they have completed the shear. They will hold the full rated
applications. They protect personnel and equipment by pressure and are rated per API standards to 350°F. These
reliably stopping unexpected surges of oil, gas and drilling rams are recommended for all applications using 95⁄8"
mud from the well bore. They seal the annulus around drill diameter pipe and below.
pipe, casing or tubing; or they can shear the drill string.
Casing shear
Our portfolio includes these types of rams: Unlike blind shears, casing shears do not have sealing
• Blind • Pipe capability. However, their advantage is the capability to
• Blind shear • Tubing shear larger pipes – almost any round pipe that will fit
• Casing • Variable through the BOP bore can be sheared by the Hydril Pressure
• Casing shear • Wireline shear Control casing shear ram.
• Fixed bore
Fixed bore
Blind rams can be provided on all our BOP models, while Our Hydril Pressure Control fixed bore rams have the ability
shear rams may require larger than standard operator size. to seal on any API casing size, drill pipe or tubular.

Blind ram Wireline shear


Our blind rams have the ability to completely shut off an The wireline shear is a special type of blind shear ram. Its
open hole while holding full-rated pressure at 350°F. distinctive design keeps the upper and lower blades in very
close proximity to each other, allowing the unit to shear
small cables along with the pipe.

Blind ram Blind shear ram

Casing ram Casing shear ram

Fixed bore ram Wireline shear ram


Where versatility & reliability meet:
the Hydril Pressure Control variable ram
Our Hydril Pressure Control variable rams (HVRs) are
designed to securely and reliably close and seal on a wide
range of pipe sizes.

Universal seal-off
The HVR has a universal seal-off feature that is especially
useful on a drill string that does not have a constant Variable ram
diameter over its length or when multiple diameters of drill
pipe are used. Two BOPs with variable rams can be used on
a tapered string to provide a backup for all drill-pipe sizes.
This application eliminates having one pipe ram for small
diameter pipe and one for large diameter pipe.

If a BOP stack is assembled with a blind or blind shear ram


and two sets of HVRs, the HVRs will seal over the BOP’s
complete range providing the backup seal-off capability
needed on a tapered string. Our Hydril Pressure Control
variable ram is therefore ideally suited to subsea use by VARIABLE RAM ASSEMBLIES
expanding the seal-off capability of each cavity within a BOP. Bore Size (inches) Pressure Rating (psi) Seal Off Range Part Number
71⁄16 3,000 23⁄8 - 27⁄8 3117555
Ram BOP Features & Benefits Sentry
5,000
11 5,000 27⁄8 - 5 3146207
Large volume of feedable rubber
13 ⁄8
5
5,000 27⁄8 - 5 3118935
The ram-block upper seal provides a large volume of feedable
3½ - 5½ 3104815
rubber to deliver a long and dependable service life.
3½ - 6 3112085
4½ - 7 3112083
Excellent compatibility
10,000 27⁄8 - 5 3118954
All Hydril Pressure Control rams have excellent functionality
3½ - 5½ 3104817
with our proven automatic multiple position locking (MPL)
3½ - 6 3104348
mechanism and the manual lock model. The automatic
5-7 3117613
MPL ensures a positive mechanical lock at all positions of
the variable ram. This means that the MPL automatically 15,000 3½ - 5 3112535

compensates as packer position changes as a result 5-7 3112536

of wear over time, or if the ram blocks are changed to 183⁄4 5,000 27⁄8 - 5 3112204
Conventional
accommodate a different pipe size. 4½ - 7 3112205
183⁄4 5,000 27⁄8 - 5½ 3117341
Compact
Tested in the lab. Proven in the field. 3½ - 5½ 3118836

The functional reliability of our Hydril Pressure Control 4½ - 7 3117342

rams has been proven by extensive testing in the lab 183⁄4 10,000 3½ - 5½ 3118836
and commercial use on wells operated around the world. 4½ - 7 3117342
Lab testing conducted per API 16A procedures includes: 15,000 3½ - 5½ 3116833
fatigue testing that has simulated over 1.5 years of service 5-7 3116836
by numerous cyclic operations, pressure tests of the ram 4½ - 7 3118844
packers, and temperature testing to determine the high 203⁄4 3,000 27⁄8 - 5 3112204
and low temperature limits of our standard packers. 4½ - 7 3112205
21 ⁄4
1
2,000 2 ⁄8 - 5
7
3112204
5,000
2,000 4½ - 7 3112205
5,000
Ram sizes for Hydril Pressure Control blowout preventers 18-15 rAM BOP ELASTOMER TEMPERATURE RATINGS
Bore Size (inches) 18-15 Compact/Conventional
Pipe Size 7 ⁄16
1
9 11 13 ⁄8
5
18 ⁄43
20 ⁄4
3
21 ⁄4
1
Ram Type Ram Size Cold Temperature Hot Temperature
Rating (F) Rating (F)
Wireline
Shear Pipe All 20 500

Blind Shear Blind Shear N/A 20 350

Blind Variable 3½ x 57⁄8 32 250

1.315 4½ x 7 30 350
5½ x 75⁄8 30 180
1.660
1.9
13-15 QUIK-LOQ RAM BOP ELASTOMER TEMPERATURE RATINGS
21⁄16
13-15 Quik-Loq™
2 ⁄8
3

Ram Type Ram Size Cold Temperature Hot Temperature


27⁄8
Rating (F) Rating (F)
3½*
Pipe All 10 350
4*
Blind Shear N/A 40* 300
4½*
Variable 3½ x 5 40* 180*
5*
5x7 40* 300
5½* Note: All temperature data and testing follows API 16A 2nd Ed. Guidelines and Procedures
57⁄8 * Denotes API 16A Temperature Rating of ‘X’ (Untested)

65⁄8 **
7
75⁄8
85⁄8
95⁄8
103⁄4
133⁄8
16
* Hanging rams are standard for 135⁄8-15,000, 183⁄4-10,000, 183⁄4-15,000 and are
optional for 135⁄8-5000, 10,000, 203⁄4-3000, 211⁄4-2000, and 211⁄4-5000.
**
Pipe ram 18" 65⁄8: This pipe ram is also good for Grant Prideco pipe ram 65⁄8 V150
drill pipe.

Operator sizes manual or MPL lock


BOP Bore Size Pressure Standard Operator Shear Ram
(inches) Rating (psi) (inches) Operator (inches)
71⁄16 3,000 5½ -
5,000 5½ -
10,000 7½ 123⁄4
15,000 10 123⁄4
9 3,000 7½ -
5,000 7½ -
11 3,000 8½ 103⁄4
5,000 8½ 103⁄4
10,000 10 123⁄4
135⁄8 3,000 10 141⁄4
5,000 10 141⁄4
10,000 14 ⁄4
1
141⁄4
15,000 141⁄4 141⁄4*
16 ⁄4 3
10,000 14 ⁄4
1
141⁄4
18 ⁄4 3
10,000 14 ⁄4
1
141⁄4
15,000 15½ 15½*
Compact BOP
20 ⁄4 3
3,000 10 141⁄4
211⁄4 2,000 10 141⁄4
5,000 141⁄4 141⁄4*
* 19" and 22" shear ram operators available on special request.
GE Oil & Gas 24/7 customer support: +1 281 449 2000
Drilling & Production
geoilandgas.com/drilling
3300 North Sam Houston Parkway East
Houston, Texas 77032
The information contained herein is general in nature
T +1 281 449 2000
and is not intended for specific construction, installation
or application purposes. GE reserves the right to make
Americas Regional Headquarters
changes in specifications or add improvements at any
4424 West Sam Houston Parkway North
time without notice or obligation.
Houston, Texas 77041
P.O. Box 2291
Houston, Texas 77252-2291
©2010 General Electric Company
T +1 713 683 2400
All Rights Reserved
F +1 713 683 2421

For complete contact information,


please refer to our website.

GE imagination at work
HY_Rams_081910
GE Oil & Gas
Drilling & Production

Hydril Pressure Control


Compact, light and reliable
Sentry™ Dual Workover blowout prevention
Ram BOP
Pressure Control Equipment: Blowout Preventers

Applications & Benefits Key Features


The 71⁄16" 3,000/5,000-psi Sentry™ Dual Workover Ram BOP This product prides itself on its ease of maintenance, flexibility,
is a field-proven pressure control tool that combines easy and optional features. More specifically, these include:
maintenance and operational flexibility with a wide range • No special tools required – all maintenance can be done
of options. It is lighter and more compact than similar with standard tools
competitive products. • Interchangeable parts between 3,000 and 5,000 psi
Sentry models
• Operates with a wide range of accumulator systems
• Rugged, one-piece ram blocks available in a wide range
of sizes
• Two 2" side outlets
• CRA-lined connection ring grooves
• Stud-to-stud connection
The Hydril Pressure Control Sentry
Advantage
The Sentry blowout preventer is a hydraulically operated unit
designed to meet the special needs of workover operations.
It is shorter and lighter than our standard Hydril Pressure
Control BOPs, but doesn’t sacrifice any of the traditional
strength and reliability.

Engineering Data
3,000 psi BOP 5,000 psi BOP
Bore 7.0625" 180 mm 7.0625" 180 mm
Working Pressure 3,000 psi 21 mPa 1,500 psi 10.3 mPa
Hydraulic Operating Pressure 1,500 psi 10.3 mPa 10,000 psi 690 mPa
Gal. to Close .33 gal 1.25 L .33 gal 1.25 L
Gal. to Open .31 gal 1.16 L .31 gal 1.16 L
Closing Ratio 4.8:1 4.8:1 4.8:1 4.8:1
Stud to Flange Height Flange Bottom Double 22.06" 560.3 mm 22.06" 560.3 mm
Single 13.06" 331.7 mm 13.06" 331.7 mm
Stud to Flange Weight Flange Bottom Double 2,450 lbs 1,111 kg 2,450 lbs 1,111 kg
Single 1,450 lbs 658 kg 1,450 lbs 658 kg
Length 65.44" 1,662 mm 65.00" 1,662 mm

3300 North Sam Houston Parkway East, Houston, TX 77032


24/7 customer support: +1 281 449 2000
geoilandgas.com/drilling

GE imagination at work
© 2010 General Electric Company. All rights reserved.
HY_SentryDW_FS_080910