Amit Hanat 807 EXP.-5 IPC

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 3

Second-Order non interacting

GIVEN
Tank 1 input flowrate(q)
Tank 2 input flowrate(q)

Tank 1 Steady State Height(h1)


Tank 2 Steady State Height(h2)

C/S area Both tanks

Resistance R1= h1/q


R2= h2/q
Time constant
Ʈ1=A1*R1
Ʈ2=A2*R2
Ʈ=sqrt(Ʈ1*Ʈ2)

no. Height Observed_cm Time taken_sec


1 19.7 0
2 19 148.19
3 18 214.41
4 17 272.78
5 16 325.13
6 15 372.26
7 14 422.18
8 13 470.18
9 12 515.99
10 11 562.84
11 10 615.89
11 9 669.53
12 8 725.73
13 7 788.14
14 6 863.82
15 5 942.9
16 4 1044.86
17 3 1180.17
18 2 1370.94
19 1 1744.19
20 0 4142.51
non interacting
5.94 cm3/s
5.94 cm3/s

19.7 cm
19.7 cm

104.04 cm2

3.31649831649832 s/cm2
3.31649831649832 s/cm2

345.048484848485 sec
345.048484848485 sec
345.048484848485

Height predicted_cm HEIGHT VS TIME


19.7
18.3283788740051 25 H_obs H_pre

17.1588158306597
16.0000046651442
20
14.9125686514699
HEIGHT

13.9234826059283
12.8864986883384 15
11.9144629668235
11.0194276470556
10
10.1438154111778
9.20647029623249
8.32088184572945 5
7.46186422356046
6.5901857500661
0
5.64572994887716 0 500 1000 1500 2000 2500 3000 3500
4.78305833346361 TIME
3.841153577956
2.8477371785379
1.84318952053682
0.760770014086685
0.001565436799012
T VS TIME
bs H_pre

00 2500 3000 3500 4000 4500


TIME