IMPORTANT NOTICE: All Product Certifications and

Specifications are Subject to Change Without Notice.

Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

300 Series 1/8 DIN Process Standard Controller CSA - General (Ordinary) Locations
Get Certificate Not Applicable
Monitor and Indicator Housing (CEC-Canada Approvals, CSA)

300 Series 1/8 DIN Process Standard Controller UL-Listed Apparatus: General/Ordinary Locations
Get Certificate Not Applicable
Monitor and Indicator Housing (NEC-USA Approvals, UL)

500 Series 1/4 DIN Process Standard Controller UL-Listed Apparatus: General/Ordinary Locations
Get Certificate Not Applicable
Controllers Housing (NEC-USA Approvals, UL)

CSA - General (Ordinary) Locations & Explosion-Proof


ACT AC Current Transmitter STD or AB Housing (CEC-Canada Approvals, CSA)
Consult Factory Not Applicable

CSA - General (Ordinary) Locations


ACX AC Current Transmitter HP Housing (CEC-Canada Approvals, CSA)
Consult Factory Not Applicable

HP Housing in 2HS, FM - Explosion-Proof: Class I, Division 1, Groups B, C, D


Dust Ignition-Proof: Class II, Division 1, Groups E, F, G
ACX AC Current Transmitter 2LS, 3HS or 3LS Suitable for use in: Class III, Division 1
Get Certificate Not Applicable
Enclosure (NEC-USA Approvals, FM)

HP Housing in 2HS, CSA - Explosion-Proof: Class I, Division 1, Groups B, C, D


ACX AC Current Transmitter 2LS, 3HS or 3LS Class II, Division 1, Groups E, F, G: Class III Get Certificate Not Applicable
Enclosure (CEC-Canada Approvals, CSA)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
HP Housing in
ACX AC Current Transmitter Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
BH Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

HP Housing in BH or
ACX AC Current Transmitter SB Enclosure (with "A" ANZEx ANZEx - Flame/Explosion-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Enclosure Suffix)

HP Housing in BH or ATEX - Flame Proof: II 2G Ex d IIC T6 Gb


ACX AC Current Transmitter SB Enclosure (with "E" Dust Ignition Protection: II 2D Ex tb IIIC Db T85C IP66 Get Certificate Not Applicable
Enclosure Suffix) (ATEX - European Union Approvals, ISSeP)

cCSAus - Class I, Groups A, B, C and D


HP Housing in
ACX AC Current Transmitter Class II, Groups E, F and G; Class III; Type 4X, IP66 Get Certificate Not Applicable
BH or SB Enclosure (CEC-Canada & NEC-USA Approvals, CSA)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
HP Housing in
ACX AC Current Transmitter Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
SB Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

Standard Housing in CSA - General (Ordinary) Locations & Explosion-Proof


ADB Analog Divider Module Consult Factory Not Applicable
EX or EXUL Enclosure (CEC-Canada Approvals, CSA)

ADM Ampliture Discriminator Standard Housing in CSA - General (Ordinary) Locations & Explosion-Proof
Consult Factory Not Applicable
Module EX or EXUL Enclosure (CEC-Canada Approvals, CSA)

Moore Industries-International, Inc. Page 1 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

CSA - General (Ordinary) Locations


ALX Alarm Trip HP Housing (CEC-Canada Approvals, CSA)
Consult Factory Not Applicable

HP Housing in 2HS, FM - Explosion-Proof: Class I, Division 1, Groups B, C, D


Dust Ignition-Proof: Class II, Division 1, Groups E, F, G
ALX Alarm Trip 2LS, 3HS or 3LS Suitable for use in: Class III, Division 1
Get Certificate Not Applicable
Enclosure (NEC-USA Approvals, FM)

HP Housing in 2HS, CSA - Explosion-Proof: Class I, Division 1, Groups B, C, D;


ALX Alarm Trip 2LS, 3HS or 3LS Class II, Division 1, Groups E, F, G; Class III Get Certificate Not Applicable
Enclosure (CEC-Canada Approvals, CSA)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
HP Housing in
ALX Alarm Trip Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
BH Enclosure Environmental Protection: NEMA 4X & IP6
(NEC-USA Approvals, FM)

HP Housing in BH or
ALX Alarm Trip SB Enclosure (with "A" ANZEx ANZEx - Flame/Explosion-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Enclosure Suffix)

HP Housing in BH or ATEX - Flame Proof: II 2G Ex d IIC T6 Gb


ALX Alarm Trip SB Enclosure (with "E" Dust Ignition Protection: II 2D Ex tb IIIC Db T85°C IP66 Get Certificate Not Applicable
Enclosure Suffix) (ATEX - European Union Approvals, ISSeP)

cCSAus Class I, Groups A, B, C and D


HP Housing in
ALX Alarm Trip Class II, Groups E, F and G; Class III; Type 4X, IP66 Get Certificate Not Applicable
BH or SB Enclosure (CEC-Canada & NEC-USA Approvals, CSA)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
HP Housing in
ALX Alarm Trip Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
SB Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

Standard Housing in CSA - General (Ordinary) Locations & Explosion-Proof


ARB Adjustable Ramp Buffer Consult Factory Not Applicable
EX or EXUL Enclosure (CEC-Canada Approvals, CSA)

Standard Housing in CSA - General (Ordinary) Locations & Explosion-Proof


ASM Adder Subtractor Module Consult Factory Not Applicable
EX or EXUL Enclosure (CEC-Canada Approvals, CSA)

Standard Housing in CSA - General (Ordinary) Locations & Explosion-Proof


AXB Analog Multiplier Module Consult Factory Not Applicable
EX or EXUL Enclosure (CEC-Canada Approvals, CSA)

1/2-Inch NPT and M20


with Sensor
BH Explosion-Proof Field-Mount
Enclosure
Assemblies; Glass or ANZEx ANZEx - Flame/Explosion-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Solid Cover (with "A"
Enclosure Suffix)
1/2-Inch NPT and M20
with Sensor ATEX - Flame/Explosion-Proof: II 2G Ex d IIC IP66
BH Explosion-Proof Field-Mount
Assemblies; Glass or Dust-Ignition-Proof: II 2D Ex tD A21 IP66 Get Certificate Not Applicable
Enclosure (ATEX - European Union Approvals, ISSeP)
Solid Cover (with "E"
Enclosure Suffix)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
BH Explosion-Proof Field-Mount 1/2-Inch NPT and M20;
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
Enclosure Glass or Solid Cover Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

Moore Industries-International, Inc. Page 2 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

cCSAus - Explosion-Proof: Class I, Groups A, B, C, D


BH Explosion-Proof Field-Mount Dust Ignition-Proof: Class II, Groups E, F, G; Class III
1/2-Inch NPT (Only) Get Certificate Not Applicable
Enclosure Environmental Protection: Type 4X & IP66
(CEC-Canada & NEC-USA Approvals, CSA)

1/2-Inch NPT FM - Environmental Protection: NEMA Type 4X & IP66


D-BOX Field-Mount Enclosure Get Certificate Not Applicable
Clear or Solid Cover (NEC-USA Approvals, FM)

CSA - General (Ordinary) Locations


DCA Direct Current Alarm Standard Housing (CEC-Canada Approvals, CSA)
Consult Factory Not Applicable

Standard Housing in CSA - General (Ordinary) Locations & Explosion-Proof


DCA Direct Current Alarm Consult Factory Not Applicable
EX or EXUL Enclosure (CEC-Canada Approvals, CSA)

DDA DIN-Style Direct Current CSA - General (Ordinary) Locations


DIN Housing Consult Factory Not Applicable
Alarm (CEC-Canada Approvals, CSA)

DPS1200 DIN Style 1200mA CSA - General (Ordinary) Locations


DIN Housing Consult Factory Not Applicable
Instrument Power Supply (CEC-Canada Approvals, CSA)

FM - Explosion-Proof: Class I, Division 1, Groups B, C, D


Dust Ignition-Proof: Class II, Division 1, Groups E, F, G
DSX Digital Indicator HP Housing Suitable for use in: Class III, Division 1
Consult Factory Not Applicable
(NEC-USA Approvals, FM)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
HP Housing in
DSX Digital Indicator Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
BH Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

HP Housing in BH or
DSX Digital Indicator SB Enclosure (with "A" ANZEx ANZEx - Flame/Explosion-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Enclosure Suffix)

HP Housing in BH or ATEX - Flame Proof: II 2G Ex d IIC T6 Gb


DSX Digital Indicator SB Enclosure (with "E" Dust Ignition Protection: II 2D Ex tb IIIC Db T85°C IP66 Get Certificate Not Applicable
Enclosure Suffix) (ATEX - European Union Approvals, ISSeP)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
HP Housing in
DSX Digital Indicator Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
SB Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

CSA - General (Ordinary) Locations


DVX Digital Indicator HP Housing (CEC-Canada Approvals, CSA)
Consult Factory Not Applicable

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
HP Housing in
DVX Digital Indicator Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
BH Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

HP Housing in BH or
DVX Digital Indicator SB Enclosure (with "A" ANZEx ANZEx - Flame/Explosion-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Enclosure Suffix)

HP Housing in BH or ATEX - Flame Proof: II 2G Ex d IIC T6 Gb


DVX Digital Indicator SB Enclosure (with "E" Dust Ignition Protection: II 2D Ex tb IIIC Db T85°C IP66 Get Certificate Not Applicable
Enclosure Suffix) (ATEX - European Union Approvals, ISSeP)

Moore Industries-International, Inc. Page 3 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

cCSAus Class I, Groups A, B, C and D


HP Housing in
DVX Digital Indicator Class II, Groups E, F and G; Class III; Type 4X, IP66 Get Certificate Not Applicable
BH or SB Enclosure (CEC-Canada & NEC-USA Approvals, CSA)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
HP Housing in
DVX Digital Indicator Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
SB Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

HP Housing in 2HG, CSA - Explosion-Proof: Class I, Division 1, Groups B, C, D


DVX Digital Indicator 2LG, 3HG or 3LG Class II, Division 1, Groups E, F, G; Class III Get Certificate Not Applicable
Enclosure (CEC-Canada Approvals, CSA)

HP Housing in 2HG, FM - Explosion-Proof: Class I, Division 1, Groups B, C, D


Dust Ignition-Proof: Class II, Division 1, Groups E, F, G
DVX Digital Indicator 2LG, 3HG or 3LG Suitable for use in: Class III, Division 1
Get Certificate Not Applicable
Enclosure (NEC-USA Approvals, FM)

cULus - Recognized Component: General/Ordinary Locations


ECA Current and Voltage Alarm ECD Housing (CEC-Canada & NEC-USA Approvals, UL)
Consult Factory Not Applicable

ECT Signal Isolators,


Converters, Repeaters and DIN Housing cULus - Listed Apparatus: General/Ordinary Locations
Get Certificate Not Applicable
Splitters (Excludes -RF Option) (CEC-Canada & NEC-USA Approvals, UL)
(25mm wide housing)

ECT Signal Isolators,


cULus - Listed Apparatus: Hazardous Locations
Converters, Repeaters and DIN Housing
Non-Incendive, Class I, Division 2, Groups A, B, C, D Get Certificate Not Applicable
Splitters (Excludes -RF Option) (CEC-Canada & NEC-USA Approvals, UL)
(25mm wide housing)

ECT Signal Isolators,


Converters, Repeaters and DIN Housing cULus - Listed Apparatus: General/Ordinary Locations
Get Certificate Not Applicable
Splitters (CEC-Canada & NEC-USA Approvals, UL)
(narrow 15mm housing)

ECT Signal Isolators,


cULus - Listed Apparatus: Hazardous Locations
Converters, Repeaters and DIN Housing
Non-Incendive, Class I, Division 2, Groups A, B, C, D Get Certificate Not Applicable
Splitters (CEC-Canada & NEC-USA Approvals, UL)
(narrow 15mm housing)

ECT Signal Isolators,


FM - Non-Incendive: Class I, Division 2, Groups A, B, C, D
Converters, Repeaters and ECD Housing (NEC-USA Approvals, FM)
Get Certificate Not Applicable
Splitters

ECT Signal Isolators,


cULus - Recognized Component: General/Ordinary Locations
Converters, Repeaters and ECD Housing (CEC-Canada & NEC-USA Approvals, UL)
Get Certificate Not Applicable
Splitters

EP-FDX Extended Performance CSA - General (Ordinary) Locations


DIN or HP Housing Consult Factory Not Applicable
Frequency-to-DC Transmitter (CEC-Canada Approvals, CSA)

HP Housing in BH or
EP-FDX Extended Performance
Frequency-to-DC Transmitter
SB Enclosure (with "A" ANZEx ANZEx - Flame/Explosion-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Enclosure Suffix)

Moore Industries-International, Inc. Page 4 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

HP Housing in BH or ATEX - Flame Proof: II 2G Ex d IIC T6 Gb


EP-FDX Extended Performance
SB Enclosure (with "E" Dust Ignition Protection: II 2D Ex tb IIIC Db T85°C IP66 Get Certificate Not Applicable
Frequency-to-DC Transmitter (ATEX - European Union Approvals, ISSeP)
Enclosure Suffix)

HP Housing in 2HS, FM - Explosion-Proof: Class I, Division 1, Groups B, C, D


EP-FDX Extended Performance Dust Ignition-Proof: Class II, Division 1, Groups E, F, G
2LS, 3HS or 3LS Get Certificate Not Applicable
Frequency-to-DC Transmitter Suitable for use in: Class III, Division 1
Enclosure (NEC-USA Approvals, FM)

cCSAus - Class I, Groups A, B, C and D


EP-FDX Extended Performance HP Housing in
Class II, Groups E, F and G; Class III; Type 4X, IP66 Get Certificate Not Applicable
Frequency-to-DC Transmitter BH or SB Enclosure (CEC-Canada & NEC-USA Approvals, CSA)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
EP-FDX Extended Performance HP Housing in
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
Frequency-to-DC Transmitter BH Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
EP-FDX Extended Performance HP Housing in
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
Frequency-to-DC Transmitter SB Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

FCT Field Configurable Signal


CSA - General (Ordinary) Locations
Converter/ DIN Housing (CEC-Canada Approvals, CSA)
Get Certificate Not Applicable
Isolator

FDT Frequency-to-DC Standard Housing in CSA - General (Ordinary) Locations & Explosion-Proof
Consult Factory Not Applicable
Transmitter EX or EXUL Enclosure (CEC-Canada Approvals, CSA)

Get Intrinsically
FDY PC-Programmable ATEX - Intrinsically Safe: II 1G EEx ia IIC, T4@60°C
HP Housing Consult Factory Safe Installation
Frequency-to-DC Converter (ATEX - European Union Approvals, LCIE)
Diagram

FM - Intrinsically Safe: Class I, II & III, Division 1, Groups A - G


Class I, Zone 0, AEx ia IIC Get Intrinsically
FDY PC-Programmable
HP Housing Non-Incendive: Class I, Division 2, Groups A, B, C, D Get Certificate Safe Installation
Frequency-to-DC Converter Temperature Code: T4@60°C Maximum Operating Ambient Diagram
(NEC-USA Approvals, FM)

CSA - Intrinsically Safe & Non Incendive; Class I, Divisions 1 &2, Groups A- Get Intrinsically
FDY PC-Programmable
HP Housing D, T4@60°C Get Certificate Safe Installation
Frequency-to-DC Converter (CEC-Canada Approvals, CSA) Diagram

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
FDY PC-Programmable HP Housing in
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
Frequency-to-DC Converter BH Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

HP Housing in BH or
FDY PC-Programmable
Frequency-to-DC Converter
SB Enclosure (with "A" ANZEx ANZEx - Flame/Explosion-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Enclosure Suffix)

Moore Industries-International, Inc. Page 5 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

HP Housing in BH or ATEX - Flame Proof: II 2G Ex d IIC T6 Gb


FDY PC-Programmable
SB Enclosure (with "E" Dust Ignition Protection: II 2D Ex tb IIIC Db T85°C IP66 Get Certificate Not Applicable
Frequency-to-DC Converter (ATEX - European Union Approvals, ISSeP)
Enclosure Suffix)

cCSAus - Class I, Groups A, B, C, D


FDY PC-Programmable HP Housing in
Class II, Groups E, F, G; Class III; Type 4X, IP66 Get Certificate Not Applicable
Frequency-to-DC Converter BH or SB Enclosure (CEC-Canada & NEC-USA Approvals, CSA)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
FDY PC-Programmable HP Housing in
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
Frequency-to-DC Converter SB Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

FPS202 Fieldbus Segment


Power Conditioner Module
Standard Fieldbus Foundation - Power Conditioner Registration Get Certificate Not Applicable
(MooreHawke FPS200 Power
Supply)

cFMus - Non-Incendive: Class I, Division 2, Groups A, B, C, D; Temperature


HCS HART-to-MODBUS RTU
DIN Housing Code: T5@85°C Get Certificate Not Applicable
Converter (CEC-Canada & NEC-USA Approvals, FM)

CSA - Ordinary and Hazardous Locations


HIM HART Loop Interface and
DIN Housing Non Incendive; Class I, Division 2, Groups A, B, C, D Get Certificate Not Applicable
Monitor (CEC-Canada Approvals, CSA)

HIM HART Loop Interface and


DIN in R-Box Housing Measurement-Canada Registration Get Certificate Not Applicable
Monitor

cCSAus - Non-Incendive: Class I, Division 2, Groups A - D


HIX HART Isolator DIN Housing (CEC-Canada & NEC-USA Approvals, CSA)
Get Certificate Not Applicable

FM - Non-Incendive: Class I, Division 2, Groups A, B, C, D


IPF Field-Mount Current-to-
WP Housing Environmental Protection: NEMA Type 4X Consult Factory Not Applicable
Pressure Transmitter (NEC-USA Approvals, FM)

IPF Field-Mount Current-to- cCSAus - Non Incendive: Class I, Division 2, Groups A - D


WP Housing Get Certificate Not Applicable
Pressure Transmitter (CEC-Canada & NEC-USA Approvals, CSA)

WDMA, WDMS, Get Intrinsically


IPH Field-Mount Current-to- ATEX - Intrinsically Safe: II 1G EEx ia IIC, T6@60°C, IP65
WDNA or WDNS Consult Factory Safe Installation
Pressure Transmitter (ATEX - European Union Approvals, LCIE)
Housing Diagram

FM - Non-Incendive: Class I, Division 2, Groups A, B, C, D


WDMA, WDMS, Suitable for use in: Class II & III, Groups F, G
IPH Field-Mount Current-to-
WDNA or WDNS Temperature Code: T6@60°C Maximum Operating Ambient Consult Factory Not Applicable
Pressure Transmitter Environmental Protection: NEMA Type 4X & IP65
Housing
(NEC-USA Approvals, FM)

CSA - Intrinsically Safe & Non Incendive


WDMA, WDMS, Class I, Div's. 1 & 2, Groups A-D; Class II, Div. 1, Groups E-G Get Intrinsically
IPH Field-Mount Current-to-
WDNA or WDNS Class II, Division 2, Groups F & G; Class III, T6@60°C Get Certificate Safe Installation
Pressure Transmitter Type 4X, Ingress Protection IP65
Housing Diagram
(CEC-Canada Approvals, CSA)

Moore Industries-International, Inc. Page 6 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

WDMA, WDMS, ANZEx - Type n & Intrinsically Safe


IPH2 Field-Mount Current to
Pressure Transmitter
WDNA or WDNS ANZEx Ex n IIC T6@55°C
Ex ia IIC T4@85°C & T5@70°C
Get Certificate Not Applicable
Housing (ANZEx - Australia & New Zealand Approvals, TestSafe)

IPT DIN-Style Current-to- cCSAus - General (Ordinary) Locations


DIN Housing Get Certificate Not Applicable
Pressure (CEC-Canada & NEC-USA Approvals, CSA)

IPT2 DIN Style Current-to- cFMus - Non-Incendive: Class I, Division 2, Groups A, B, C, D


DIN Housing Get Certificate Not Applicable
Pressure Transmitter (CEC-Canada & NEC-USA Approvals, FM)

IPT2 DIN Style Current-to-


Pressure Transmitter
DIN Housing ANZEx ANZEx - Type n: Ex n IIC T6@55°C
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable

ATEX - Intrinsically Safe: II 1G Ex ia IIC T4 Ga Get Intrinsically


IPX2 Field-Mount Current-to- EXI Enclosure
Tamb = -40°C to +85°C Get Certificate Safe Installation
Pressure Transmitter Natural Gas (-NG) (ATEX - European Union Approvals, SIRA) Diagram

cCSAus - Explosion-Proof: Class I, Div. 1, Grps. A, B, C, D


Class II, Div. 1 & 2, Grps. E, F, G; Class III, Div. 1 & 2
T4@85°C, T4A@70°C, T5@55°C
Class I, Zone 1, AEx d IIC, Ex d IIC, T4@85°C/T4@70°C/T5@55°C
Intrinsically Safe: Class I, Div. 1 & 2, Grps. A, B, C, D Get Intrinsically
IPX2 Field-Mount Current-to- EXI Enclosure Class II, Div. 1 & 2, Grps. E, F, G; Class III, Div. 1 & 2
Get Certificate Safe Installation
Pressure Transmitter Natural Gas (-NG) T4@85°C, T5@70°C, T6@55°C
Class I, Zone 0, AEx ia IIC, Ex ia IIC, T4@85°C, T5@70°C, T6@55°C; Diagram
Suitable for use in: Class I, Division 2 or Zone 2
T4@85°C, T5@70°C, T6@55°C
Environmental Protection: Type 4X & IP66
(CEC-Canada & NEC-USA Approvals, CSA)

EXI and EXIM ATEX - Intrinsically Safe: II 1G Ex ia IIC T4 Ga Get Intrinsically


IPX2 Field-Mount Current-to-
Enclosures Tamb = -40°C to +85°C Get Certificate Safe Installation
Pressure Transmitter (ATEX - European Union Approvals, SIRA)
Standard (Air) Diagram

EXI and EXIM ATEX - Flame-Proof: II 2 GD Ex d IIC T4 Gb, Ex tb IIIC T127°C Db


IPX2 Field-Mount Current-to-
Enclosures Tamb = -40°C to +85°C Get Certificate Not Applicable
Pressure Transmitter (ATEX - European Union Approvals, SIRA)
Standard (Air)

EXI and EXIM


IPX2 Field-Mount Current-to-
Pressure Transmitter
Enclosures ANZEx ANZEx - Type n: Ex n IIC T6@55°C
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Standard (Air)

cCSAus - Explosion-Proof: Class I, Div. 1, Grps. A, B, C, D


Class II, Div. 1 & 2, Grps. E, F, G; Class III, Div. 1 & 2
T4@85°C, T4A@70°C, T5@55°C
Class I, Zone 1, AEx d IIC, Ex d IIC, T4@85°C/T4@70°C/T5@55°C
Intrinsically Safe: Class I, Div. 1 & 2, Grps. A, B, C, D
EXI and EXIM Class II, Div. 1 & 2, Grps. E, F, G; Class III, Div. 1 & 2 Get Intrinsically
IPX2 Field-Mount Current-to-
Enclosures T4@85°C, T5@70°C, T6@55°C Get Certificate Safe Installation
Pressure Transmitter Class I, Zone 0, AEx ia IIC, Ex ia IIC, T4@85°C, T5@70°C, T6@55°C
Standard (Air) Diagram
Non-Incendive/Non-Sparking: Class I, Div. 2, Grps. A, B, C, D
Class I, Zone 2, AEx nA IIC, Ex nA IIC
T4@85°C, T5@70°C, T6@55°C
Environmental Protection: Type 3X & IP56
(CEC-Canada & NEC-USA Approvals, CSA)

Moore Industries-International, Inc. Page 7 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

EXI and EXIM


Get Intrinsically
IPX2 Field-Mount Current-to- Enclosures; Standard
Pressure Transmitter (Air) and -NG (Natural ANZEx ANZEx - Intrinsically Safe: Ex ia IIC T4@85°C & T5@70°C
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Safe Installation
Diagram
Gas)

IST DIN-Style Signal Isolator, cCSAus - General (Ordinary) Locations


DIN Housing Get Certificate Not Applicable
Converter and Splitter (CEC-Canada & NEC-USA Approvals, CSA)

LH1 Field-Mount Enclosure All Enclosure Models FM - Environmental Protection: NEMA Type 4X & IP66 Get Certificate Not Applicable

1/2-Inch NPT and M20;


Solid Cover cCSAus - Explosion-Proof: Class I, Groups A - D
Dust Ignition-Proof: Class II, Groups E, F, G & Class III
LH2 Field-Mount Enclosure (Canada: 1/2-Inch NPT Environmental Protection: IP66
Get Certificate Not Applicable
only) (CEC-Canada & NEC-USA Approvals, CSA)

1/2-Inch NPT and M20; FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
LH2 Field-Mount Enclosure Solid Cover Environmental Protection: NEMA Type 4X & IP66
Get Certificate Not Applicable
(NEC-USA Approvals, FM)

1/2-Inch NPT and M20;


Solid Cover with
LH2 Field-Mount Enclosure Sensor Assemblies ANZEx ANZEx - Flame-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
(with "A" Enclosure
Suffix)

1/2-Inch NPT and M20


ATEX - Flame/Explosion-Proof: II 2G Ex d IIC IP66
with Sensor
LH2 Field-Mount Enclosure Dust-Ignition-Proof: II 2D Ex tD A21 IP66 Get Certificate Not Applicable
Assemblies (with "E" (ATEX - European Union Approvals, ISSeP)
Enclosure Suffix)

Standard Housing in CSA - General (Ordinary) Locations & Explosion-Proof


LIT Linear Integrating Totalizer Consult Factory Not Applicable
EX or EXUL Enclosure (CEC-Canada Approvals, CSA)

cFMus - Non-Incendive: Class I, Division 2, Groups A, B, C, D;


LRX Low Power Temperature
HP Housing Temperature Code: T5@85°C & T6@70°C Get Certificate Not Applicable
Transmitter (CEC-Canada & NEC-USA Approvals, FM)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
LRX Low Power Temperature HP Housing in
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
Transmitter BH Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

cCSAus - Class I, Groups A, B, C and D


LRX Low Power Temperature HP Housing in
Class II, Groups E, F and G; Class III; Type 4X, IP66 Get Certificate Not Applicable
Transmitter BH or SB Enclosure (CEC-Canada & NEC-USA Approvals, CSA)

HP Housing in BH or
LRX Low Power Temperature
Transmitter
SB Enclosure (with "A" ANZEx ANZEx - Flame-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Enclosure Suffix)

MIT miniMOORE Multi-Channel cCSAus - Non-Incendive: Class I, Division 2, Groups A - D


DIN Housing Get Certificate Not Applicable
Signal Isolator and Converter (CEC-Canada & NEC-USA Approvals, CSA)

MIT miniMOORE Multi-Channel cULus - Listed Apparatus: General/Ordinary Locations


DIN Housing Get Certificate Not Applicable
Signal Isolator and Converter (CEC-Canada & NEC-USA Approvals, UL)

Moore Industries-International, Inc. Page 8 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

MIX miniMOORE Multi-Channel cCSAus - Non-Incendive: Class I, Division 2, Groups A - D


DIN Housing Get Certificate Not Applicable
Signal Isolator and Converter (CEC-Canada & NEC-USA Approvals, CSA)

MIX miniMOORE Multi-Channel cULus - Listed Apparatus: General/Ordinary Locations


DIN Housing Get Certificate Not Applicable
Signal Isolator and Converter (CEC-Canada & NEC-USA Approvals, UL)

Standard Housing in CSA - General (Ordinary) Locations & Explosion-Proof


MVA Millivolt Alarm Consult Factory Not Applicable
EX or EXUL Enclosure (CEC-Canada Approvals, CSA)

Standard Housing in CSA - General (Ordinary) Locations & Explosion-Proof


MVT Millivolt Transmitter Consult Factory Not Applicable
EX or EXUL Enclosure (CEC-Canada Approvals, CSA)

CSA - General (Ordinary) Locations


MVX Millivolt Transmitter DIN or HP Housings (CEC-Canada Approvals, CSA)
Consult Factory Not Applicable

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
HP Housing in
MVX Millivolt Transmitter Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
BH Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

HP Housing in BH or
MVX Millivolt Transmitter SB Enclosure (with "A" ANZEx ANZEx - Flame-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Enclosure Suffix)

HP Housing in BH or ATEX - Flame Proof: II 2G Ex d IIC T6 Gb


MVX Millivolt Transmitter SB Enclosure (with "E" Dust Ignition Protection: II 2D Ex tb IIIC Db T85°C IP66 Get Certificate Not Applicable
Enclosure Suffix) (ATEX - European Union Approvals, ISSeP)

cCSAus - Class I, Groups A, B, C and D


HP Housing in
MVX Millivolt Transmitter Class II, Groups E, F and G; Class III; Type 4X, IP66 Get Certificate Not Applicable
BH or SB Enclosure (CEC-Canada & NEC-USA Approvals, CSA)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
HP Housing in
MVX Millivolt Transmitter Temperature Code: T6@60°C Maximum Operating Ambient; Get Certificate Not Applicable
SB Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

HP Housing in 2HS, CSA - Explosion-Proof: Class I, Division 1, Groups B, C, D


MVX Millivolt Transmitter 2LS, 3HS or 3LS Class II, Division 1, Groups E, F, G: Class III Get Certificate Not Applicable
Enclosure (CEC-Canada Approvals, CSA)

HP Housing in 2HS, FM - Explosion-Proof: Class I, Division 1, Groups B, C, D


Dust Ignition-Proof: Class II, Division 1, Groups E, F, G
MVX Millivolt Transmitter 2LS, 3HS or 3LS Suitable for use in: Class III, Division 1
Get Certificate Not Applicable
Enclosure (NEC-USA Approvals, FM)

Moore Industries-International, Inc. Page 9 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

NCS NET Concentrator System:


cFMus - Non-Incendive: Class I, Division 2, Groups A, B, C, D
(AIM, AOM, CPM, DIM-CC, DIM-
DIN Housing Temperature Code: T3@85°C, T4@60°C & T4A@40°C Get Certificate Not Applicable
HV, DIM-LV, EIM, EMM, (CEC-Canada & NEC-USA Approvals, FM)
MIM, ROM & TIM)

cULus - Listed Apparatus: General/Ordinary Locations


PAC AC Current Transducer DM or SM Housing (CEC-Canada & NEC-USA Approvals, UL)
Get Certificate Not Applicable

cULus - Listed Apparatus: General/Ordinary Locations


PAV AC Voltage Transducer DM or SM Housing (CEC-Canada & NEC-USA Approvals, UL)
Get Certificate Not Applicable

PIT Pressure-to-Current FM - Non-Incendive: Class I, Division 2, Groups A, B, C, D


DIN Housing Get Certificate Not Applicable
Transmitter (NEC-USA Approvals, FM)

PIT Pressure-to-Current CSA - General (Ordinary ) Locations


DIN Housing Get Certificate Not Applicable
Transmitter (CEC-Canada Approvals, CSA)

PIT Pressure-to-Current 4-Wire, CSA - General (Ordinary) Locations


Consult Factory Not Applicable
Transmitter Standard Housing (CEC-Canada Approvals, CSA)

PIX Explosion-Proof Pressure-to- CSA - General (Ordinary) Locations & Explosion-Proof


EXI Housing Consult Factory Not Applicable
Current Transmitter (CEC-Canada Approvals, CSA)

FM - Explosion-Proof: Class I, Division 1, Groups B, C, D


PIX Explosion-Proof Pressure-to- Dust Ignition-Proof: Class II, Division 1, Groups E, F, G
EXI or EXIP Housing Consult Factory Not Applicable
Current Transmitter Suitable for use in: Class III, Division 1
(NEC-USA Approvals, FM)

PIX Explosion-Proof Pressure-to- FM - Non-Incendive: Class I, Division 2, Groups A, B, C, D


HP Housing Get Certificate Not Applicable
Current Transmitter (NEC-USA Approvals, FM)

PIX Explosion-Proof Pressure-to- HP Housing CSA - General (Ordinary) Locations & Intrinsically Safe
Consult Factory Not Applicable
Current Transmitter (with -ISC Option) (CEC-Canada Approvals, CSA)

HP Housing in 2HS, CSA - Explosion-Proof: Class I, Division 1, Groups B, C, D


PIX Explosion-Proof Pressure-to-
2LS, 3HS or 3LS Class II, Division 1, Groups E, F, G: Class III Get Certificate Not Applicable
Current Transmitter (CEC-Canada Approvals, CSA)
Enclosure

Get Intrinsically
PSD PC-Programmable 4- HP Housing ATEX - Intrinsically Safe: II 1G Ex ia IIC, T4@85oC
Get Certificate Safe Installation
20mA Loop Display (with -ISE option) (ATEX - European Union Approvals, LCIE)
Diagram

CSA - Intrinsically Safe & Non Incendive: Get Intrinsically


PSD PC-Programmable 4- Class I, Divisions 1 & 2, Groups A-D
HP Housing Get Certificate Safe Installation
20mA Loop Display Temperature Code: T5@60°C & T6@40°C
(CEC-Canada Approvals, CSA) Diagram

Moore Industries-International, Inc. Page 10 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

FM - Intrinsically Safe: Class I, II, III; Division 1, Groups A-G Get Intrinsically
PSD PC-Programmable 4- HP Housing Non-Incendive: Class I, Division 2, Groups A-D
Get Certificate Safe Installation
20mA Loop Display (with -ISF Option) Temperature Code: T5@60°C & T6@40°C Max. Op. Ambient
(NEC-USA Approvals, FM) Diagram

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
PSD PC-Programmable 4- HP Housing in
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
20mA Loop Display BH Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

HP Housing in BH or
PSD PC-Programmable 4-
20mA Loop Display
SB Enclosure (with "A" ANZEx ANZEx - Flame-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Enclosure Suffix)

HP Housing in BH or ATEX - Flame Proof: II 2G Ex d IIC T6 Gb


PSD PC-Programmable 4-
SB Enclosure (with "E" Dust Ignition Protection: II 2D Ex tb IIIC Db T85°C IP66 Get Certificate Not Applicable
20mA Loop Display (ATEX - European Union Approvals, ISSeP)
Enclosure Suffix)

cCSAus - Class I, Groups A, B, C and D


PSD PC-Programmable 4- HP Housing in
Class II, Groups E, F and G; Class III; Type 4X, IP66 Get Certificate Not Applicable
20mA Loop Display BH or SB Enclosure (CEC-Canada & NEC-USA Approvals, CSA)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
PSD PC-Programmable 4- HP Housing in
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
20mA Loop Display SB Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

Standard Housing in CSA - General (Ordinary) Locations & Explosion-Proof


PTT Potentiometer Transmitter Consult Factory Not Applicable
EX or EXUL Enclosure (CEC-Canada Approvals, CSA)

CSA - General (Ordinary) Locations


PTX Potentiometer Transmitter DIN or HP Housing (CEC-Canada Approvals, CSA)
Consult Factory Not Applicable

HP Housing CSA - Intrinsically Safe; Class I, Division 1, Groups A, B, C, D


PTX Potentiometer Transmitter Consult Factory Not Applicable
(with -ISC Option) (CEC-Canada Approvals, CSA)

HP Housing in 2HS, CSA - Explosion-Proof: Class I, Division 1, Groups B, C, D


PTX Potentiometer Transmitter 2LS, 3HS or 3LS Class II, Division 1, Groups E, F, G: Class III Get Certificate Not Applicable
Enclosure (CEC-Canada Approvals, CSA)

HP Housing in 2HS, FM - Explosion-Proof: Class I, Division 1, Groups B, C, D


Dust Ignition-Proof: Class II, Division 1, Groups E, F, G
PTX Potentiometer Transmitter 2LS, 3HS or 3LS Suitable for use in: Class III, Division 1
Get Certificate Not Applicable
Enclosure (NEC-USA Approvals, FM)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
HP Housing in
PTX Potentiometer Transmitter Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
BH Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

HP Housing in BH or
PTX Potentiometer Transmitter SB Enclosure (with "A" ANZEx ANZEx - Flame-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Enclosure Suffix)

HP Housing in BH or ATEX - Flame Proof: II 2G Ex d IIC T6 Gb


PTX Potentiometer Transmitter SB Enclosure (with "E" Dust Ignition Protection: II 2D Ex tb IIIC Db T85°C IP66 Get Certificate Not Applicable
Enclosure Suffix) (ATEX - European Union Approvals, ISSeP)

Moore Industries-International, Inc. Page 11 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

cCSAus - Class I, Groups A, B, C and D


HP Housing in
PTX Potentiometer Transmitter Class II, Groups E, F and G; Class III; Type 4X, IP66 Get Certificate Not Applicable
BH or SB Enclosure (CEC-Canada & NEC-USA Approvals, CSA)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
HP Housing in
PTX Potentiometer Transmitter Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
SB Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

PVT AC Power (VAR) cULus - Listed Apparatus: General/Ordinary Locations


DM or SM Housing Get Certificate Not Applicable
Transducer (CEC-Canada & NEC-USA Approvals, UL)

PWT AC Power (Watt) cULus - Listed Apparatus: General/Ordinary Locations


DM or SM Housing Get Certificate Not Applicable
Transducer (CEC-Canada & NEC-USA Approvals, UL)

PWV AC Power (Watt/VAR) cULus - Listed Apparatus: General/Ordinary Locations


DM or SM Housing Get Certificate Not Applicable
Transducer (CEC-Canada & NEC-USA Approvals, UL)

Standard housing in CSA - General (Ordinary) Locations & Explosion-Proof


RBA RTD Alarm Consult Factory Not Applicable
EX or EXUL Enclosure (CEC-Canada Approvals, CSA)

Standard housing in CSA - General (Ordinary) Locations & Explosion-Proof


RBT RTD Transmitter Consult Factory Not Applicable
EX or EXUL Enclosure (CEC-Canada Approvals, CSA)

CSA - General (Ordinary) Locations


RBX RTD Transmitter DIN or HP Housing (CEC-Canada Approvals, CSA)
Consult Factory Not Applicable

HP Housing CSA - Intrinsically Safe; Class I, Division 1, Groups A, B, C, D


RBX RTD Transmitter Consult Factory Not Applicable
(with -ISC Option) (CEC-Canada Approvals, CSA)

HP Housing in 2HS, CSA - Explosion-Proof: Class I, Division 1, Groups B, C, D


RBX RTD Transmitter 2LS, 3HS or 3LS Class II, Division 1, Groups E, F, G: Class III Get Certificate Not Applicable
Enclosure (CEC-Canada Approvals, CSA)

HP Housing in 2HS, FM - Explosion-Proof: Class I, Division 1, Groups B, C, D


Dust Ignition-Proof: Class II, Division 1, Groups E, F, G
RBX RTD Transmitter 2LS, 3HS or 3LS Suitable for use in: Class III, Division 1
Get Certificate Not Applicable
Enclosure (NEC-USA Approvals, FM)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


HP Housing in Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
RBX RTD Transmitter Get Certificate Not Applicable
BH Enclosure Temperature Code: T6@60°C Maximum Operating Ambient
Environmental Protection: NEMA 4X & IP66 (NEC-USA Approvals, FM)

HP Housing in BH or
RBX RTD Transmitter SB Enclosure (with "A" ANZEx ANZEx - Flame-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Enclosure Suffix)

HP Housing in BH or ATEX - Flame Proof: II 2G Ex d IIC T6 Gb


RBX RTD Transmitter SB Enclosure (with "E" Dust Ignition Protection: II 2D Ex tb IIIC Db T85°C IP66 Get Certificate Not Applicable
Enclosure Suffix) (ATEX - European Union Approvals, ISSeP)

Moore Industries-International, Inc. Page 12 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

cCSAus - Class I, Groups A, B, C and D


HP Housing in
RBX RTD Transmitter Class II, Groups E, F and G; Class III; Type 4X, IP66 Get Certificate Not Applicable
BH or SB Enclosure (CEC-Canada & NEC-USA Approvals, CSA)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
HP Housing in
RBX RTD Transmitter Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
SB Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

CSA - General (Ordinary) Locations


RDA RTD Alarm DIN Housing (CEC-Canada Approvals, CSA)
Consult Factory Not Applicable

RIY Site-Programmable RTD CSA - General (Ordinary) Locations


DIN or HP Housing Consult Factory Not Applicable
Transmitter (CEC-Canada Approvals, CSA)

RIY Site-Programmable RTD FM - Non-Incendive: Class I, Division 2, Groups A, B, C, D


DIN or HP Housing Get Certificate Not Applicable
Transmitter (NEC-USA Approvals, FM)

Get Intrinsically
RIY Site-Programmable RTD HP Housing CSA - Intrinsically Safe: Class I, Groups A, B, C, D
Get Certificate Safe Installation
Transmitter (with -ISC Option) (CEC-Canada Approvals, CSA)
Diagram

HP Housing in 2HS, FM - Explosion-Proof: Class I, Division 1, Groups B, C, D


RIY Site-Programmable RTD Dust Ignition-Proof: Class II, Division 1, Groups E, F, G
2LS, 3HS or 3LS Get Certificate Not Applicable
Transmitter Suitable for use in: Class III, Division 1
Enclosure (NEC-USA Approvals, FM)

HP Housing in 2HS, CSA - Explosion-Proof: Class I, Groups B, C, D


RIY Site-Programmable RTD
2LS, 3HS or 3LS Class II, Groups E, F, G; Class III Get Certificate Not Applicable
Transmitter (CEC-Canada Approvals, CSA)
Enclosure

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
RIY Site-Programmable RTD HP Housing in
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
Transmitter BH Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

HP Housing in BH or
RIY Site-Programmable RTD
Transmitter
SB Enclosure (with "A" ANZEx ANZEx - Flame-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Enclosure Suffix)

HP Housing in BH or ATEX - Flame Proof: II 2G Ex d IIC T6 Gb


RIY Site-Programmable RTD
SB Enclosure (with "E" Dust Ignition Protection: II 2D Ex tb IIIC Db T85°C IP66 Get Certificate Not Applicable
Transmitter (ATEX - European Union Approvals, ISSeP)
Enclosure Suffix)

cCSAus - Class I, Groups A, B, C and D


RIY Site-Programmable RTD HP Housing in
Class II, Groups E, F and G; Class III; Type 4X, IP66 Get Certificate Not Applicable
Transmitter BH or SB Enclosure (CEC-Canada & NEC-USA Approvals, CSA)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
RIY Site-Programmable RTD HP Housing in
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
Transmitter SB Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

ATEX - Intrinsically Safe, Encapsulation and Increased Safety: Get Intrinsically


II (1) G [EEx ia] IIB; II 1 G EEx ia IIB; II (1) G EEx [ia] IIC
RM100, RMA100 & RMA100C Safe Field
Standard II 2 (1) G EEx me [ia] IIC Consult Factory
Fieldbus System, MooreHawke Temperature Code: T4@70°C Installation
(ATEX - European Union Approvals, SIRA) Diagram

Moore Industries-International, Inc. Page 13 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

cFMus - Intrinsically Safe: Class I, Division 1, Groups C & D Get Intrinsically


RM100 & RMA100 Fieldbus Associated I.S.: Class I, Division 1, Groups A, B, C, D Safe Field
Standard Get Certificate
System, MooreHawke Temperature Code: T4@70°C Max. Op. Ambient Installation
(CEC-Canada & NEC-USA Approvals, FM) Diagram

cCSAus - Explosion-Proof: Class I, Groups A, B, C, D


SB Stainless Steel Explosion- Dust Ignition-Proof: Class II, Groups E, F, G; Class III
1/2-Inch NPT (Only) Get Certificate Not Applicable
Proof Enclosure Environmental Protection: Type 4X & IP66
(CEC-Canada & NEC-USA Approvals, CSA)

1/2-Inch NPT and M20


with Sensor
SB Stainless Steel Explosion-
Proof Enclosure
Assemblies; Glass or ANZEx ANZEx - Flame-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Solid Cover (with "A"
Enclosure Suffix)

1/2-Inch NPT and M20


with Sensor ATEX - Flame/Explosion-Proof: II 2G Ex d IIC IP66
SB Stainless Steel Explosion-
Assemblies; Glass or Dust-Ignition-Proof: II 2D Ex tD A21 IP66 Get Certificate Not Applicable
Proof Enclosure (ATEX - European Union Approvals, ISSeP)
Solid Cover (with "E"
Enclosure Suffix)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
SB Stainless Steel Explosion- 1/2-Inch NPT and M20;
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
Proof Enclosure Glass or Solid Cover Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

Standard Housing in CSA - General (Ordinary) Locations & Explosion-Proof


SCT Signal Converter Consult Factory Not Applicable
EX or EXUL Enclosure (CEC-Canada Approvals, CSA)

SCX Signal Isolator and CSA - General (Ordinary) Locations


HP Housing Consult Factory Not Applicable
Converter (CEC-Canada Approvals, CSA)

SCX Signal Isolator and FM - Non-Incendive: Class I, Division 2, Groups A, B, C, D


DIN or HP Housing Get Certificate Not Applicable
Converter (NEC-USA Approvals, FM)

SCX Signal Isolator and DIN Housing cULus - Listed Apparatus: General/Ordinary Locations
Get Certificate Not Applicable
Converter (Excludes -RF Option) (CEC-Canada & NEC-USA Approvals, UL)

cULus - Listed Apparatus: Hazardous Locations


SCX Signal Isolator and DIN Housing
Non-Incendive, Class I, Division 2, Groups A, B, C, D Get Certificate Not Applicable
Converter (Excludes -RF Option) (CEC-Canada & NEC-USA Approvals, UL)

HP Housing in 2HS, FM - Explosion-Proof: Class I, Division 1, Groups B, C, D


SCX Signal Isolator and Dust Ignition-Proof: Class II, Division 1, Groups E, F, G
2LS, 3HS or 3LS Get Certificate Not Applicable
Converter Suitable for use in: Class III, Division 1
Enclosure (NEC-USA Approvals, FM)

HP Housing in 2HS, CSA - Explosion-Proof: Class I, Division 1, Groups B, C, D


SCX Signal Isolator and
2LS, 3HS or 3LS Class II, Division 1, Groups E, F, G: Class III Get Certificate Not Applicable
Converter (CEC-Canada Approvals, CSA)
Enclosure

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
SCX Signal Isolator and HP Housing in BH
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
Converter Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

HP Housing in BH or
SCX Signal Isolator and
Converter
SB Enclosure (with "A" ANZEx ANZEx - Flame-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Enclosure Suffix)

Moore Industries-International, Inc. Page 14 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

HP Housing in BH or ATEX - Flame Proof: II 2G Ex d IIC T6 Gb


SCX Signal Isolator and
SB Enclosure (with "E" Dust Ignition Protection: II 2D Ex tb IIIC Db T85°C IP66 Get Certificate Not Applicable
Converter (ATEX - European Union Approvals, ISSeP)
Enclosure Suffix)

cCSAus - Class I, Groups A, B, C and D


SCX Signal Isolator and HP Housing in
Class II, Groups E, F and G; Class III; Type 4X, IP66 Get Certificate Not Applicable
Converter BH or SB Enclosure (CEC-Canada & NEC-USA Approvals, CSA)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
SCX Signal Isolator and HP Housing in
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
Converter SB Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

SDY PC-Programmable ATEX - Intrinsically Safe: II 1G Ex ia IIC T4 Ga Get Intrinsically


HP Housing
Isolator/ Tamb = -40°C to +85°C Get Certificate Safe Installation
(-IS Option Required) (ATEX - European Union Approvals, FM)
Converter with Display Diagram

SDY PC-Programmable FM - Intrinsically Safe: Class I, Division 1, Groups A, B, C & D Get Intrinsically
HP Housing Class I, Zone 0, AEx ia IIC T4
Isolator/ Get Certificate Safe Installation
(-IS Option Required) Temperature Class: T4 Tamb = -40°C to +85°C
Converter with Display (CEC-Canada & NEC-USA Approvals, FM) Diagram

SDY PC-Programmable IECEx - Intrinsically Safe: Ex ia IIC T4 Ga Get Intrinsically


HP Housing
Isolator/ Tamb = -40°C to +85°C Get Certificate Safe Installation
(-IS Option Required) (IECEx Approvals, FM)
Converter with Display Diagram

SDY PC-Programmable ATEX - Non-Sparking: II 3G Ex nA IIC T4 Ga


Isolator/ HP Housing Tamb = -40°C to +85°C Get Certificate Not Applicable
Converter with Display (ATEX - European Union Approvals, FM)

SDY PC-Programmable FM - Non-Incendive: Class I, Division 2, Groups A, B, C & D


Class I, Zone 2, AEx nA IIC T4
Isolator/ HP Housing Temperature Class: T4 Tamb = -40°C to +85°C
Get Certificate Not Applicable
Converter with Display (CEC-Canada & NEC-USA Approvals, FM)

SDY PC-Programmable IECEx - Non-Sparking: Ex nA IIC T4 Ga


Isolator/ HP Housing Tamb = -40°C to +85°C Get Certificate Not Applicable
Converter with Display (IECEx Approvals, FM)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


SDY PC-Programmable Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
HP Housing in
Isolator/ Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
BH Enclosure Environmental Protection: NEMA 4X & IP66
Converter with Display
(NEC-USA Approvals, FM)

HP Housing in BH or
SDY PC-Programmable
Isolator/Converter with Display
SB Enclosure (with "A" ANZEx ANZEx - Flame-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Enclosure Suffix)

HP Housing in BH or ATEX - Flame Proof: II 2G Ex d IIC T6 Gb


SDY PC-Programmable
SB Enclosure (with "E" Dust Ignition Protection: II 2D Ex tb IIIC Db T85°C IP66 Get Certificate Not Applicable
Isolator/Converter with Display (ATEX - European Union Approvals, ISSeP)
Enclosure Suffix)

cCSAus - Class I, Groups A, B, C and D


SDY PC-Programmable HP Housing in
Class II, Groups E, F and G; Class III; Type 4X, IP66 Get Certificate Not Applicable
Isolator/Converter with Display BH or SB Enclosure (CEC-Canada & NEC-USA Approvals, CSA)

Moore Industries-International, Inc. Page 15 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
SDY PC-Programmable HP Housing in
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
Isolator/Converter with Display SB Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

FM - Non-Incendive: Class I, Division 2, Groups A, B, C, D


SFY Functional Safety
HP Housing Temperature Code: T4@60°C Maximum Operating Ambient Get Certificate Not Applicable
Frequency-to-DC Converter (NEC-USA Approvals, FM)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
SFY Functional Safety HP Housing in
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
Frequency-to-DC Converter BH Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
SFY Functional Safety HP Housing in
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
Frequency-to-DC Converter SB Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

cCSAus - Class I, Groups A, B, C and D


SFY Functional Safety HP Housing in
Class II, Groups E, F and G; Class III; Type 4X, IP66 Get Certificate Not Applicable
Frequency-to-DC Converter BH or SB Enclosure (CEC-Canada & NEC-USA Approvals, CSA)

Standard Housing in CSA - General (Ordinary) Locations & Explosion-Proof


SGT Strain Gage Transmitter Consult Factory Not Applicable
EX or EXUL Enclosure (CEC-Canada Approvals, CSA)

SHM Sample and Holding Standard Housing in CSA - General (Ordinary) Locations & Explosion-Proof
Consult Factory Not Applicable
Module EX or EXUL Enclosure (CEC-Canada Approvals, CSA)

SIT Square Root Integrating Standard Housing in CSA - General (Ordinary) Locations & Explosion-Proof
Consult Factory Not Applicable
Module EX or EXUL Enclosure (CEC-Canada Approvals, CSA)

SIX Signal Isolator and FM - Non-Incendive: Class I, Division 2, Groups A, B, C, D


DIN Housing Get Certificate Not Applicable
Converter (NEC-USA Approvals, FM)

SIX Signal Isolator and cCSAus - General (Ordinary) Locations


DIN Housing Get Certificate Not Applicable
Converter (CEC-Canada & NEC-USA Approvals, CSA)

SIX Signal Isolator and


cULus - Listed Apparatus: General/Ordinary Locations
Converter DIN Housing (CEC-Canada & NEC-USA Approvals, UL)
Get Certificate Not Applicable
(Q4 2019 Release)

SIX Signal Isolator and cULus - Listed Apparatus: Hazardous Locations


Converter DIN Housing Non-Incendive, Class I, Division 2, Groups A, B, C, D Get Certificate Not Applicable
(Q4 2019 Release) (CEC-Canada & NEC-USA Approvals, UL)

SIY PC-Programmable Signal cCSAus - General (Ordinary) Locations


DIN Housing Get Certificate Not Applicable
Isolator and Converter (CEC-Canada & NEC-USA Approvals, CSA)

Moore Industries-International, Inc. Page 16 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

Get Intrinsically
SIY PC-Programmable Signal HPP Housing ATEX - Intrinsically Safe: II 2G EEx ib IIC, T6@60°C
Consult Factory Safe Installation
Isolator and Converter (with -ISE Option) (ATEX - European Union Approvals, LCIE)
Diagram

CSA - Intrinsically Safe & Non Incendive: Get Intrinsically


SIY PC-Programmable Signal HPP Housing
Class I, Divisions 1 & 2, Groups A - D, T6@60°C Get Certificate Safe Installation
Isolator and Converter (with -ISC Option) (CEC-Canada Approvals, CSA) Diagram

FM - Intrinsically Safe: Class I, Division 1, Groups A, B, C & D T6


Class I, Zone 0, AEx ia IIC T6 Ga Get Intrinsically
SIY PC-Programmable Signal
HPP Housing Non-Incendive: Class I, Division 2, Groups A, B, C & D T6 Get Certificate Safe Installation
Isolator and Converter Temperature Code: T6@60°C Maximum Operating Ambient Diagram
(NEC-USA Approvals, FM)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
SIY PC-Programmable Signal HPP Housing in
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
Isolator and Converter LH2 Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

cCSAus - Class I, Groups A, B, C and D


SIY PC-Programmable Signal HPP Housing in
Class II, Groups E, F and G; Class III; IP66 Get Certificate Not Applicable
Isolator and Converter LH2 Enclosure (CEC-Canada & NEC-USA Approvals, CSA)

HPP Housing in LH2 ATEX - Flame Proof: II 2G Ex d IIC T6 Gb


SIY PC-Programmable Signal
Enclosure (with "E" Dust Ignition Protection: II 2D Ex tb IIIC Db T85°C IP66 Get Certificate Not Applicable
Isolator and Converter (ATEX - European Union Approvals, ISSeP)
Enclosure Suffix)

HPP Housing in LH2


SIY PC-Programmable Signal Enclosure, Solid Cover
Isolator and Converter (with "A" Enclosure ANZEx ANZEx - Flame-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Suffix)

Get Instinsically
SLD Functional Safety Loop HP Housing ATEX - Intrinsically Safe: II 1G Ex ia IIC, T4@85oC
Get Certificate Safe Installation
Display (with -ISE option) (ATEX - European Union Approvals, LCIE)
Diagram

FM - Non-Incendive: Class I, Division 2, Groups A-D


SLD Functional Safety Loop
HP Housing Temperature Code: T5@60°C & T6@40°C Max. Op. Ambient Get Certificate Not Applicable
Display (NEC-USA Approvals, FM)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
SLD Functional Safety Loop HP Housing in
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
Display BH Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
SLD Functional Safety Loop HP Housing in
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
Display SB Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

Moore Industries-International, Inc. Page 17 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

HP Housing in BH or
SLD Functional Safety Loop SB Enclosure
Display (with "A" Enclosure ANZEx ANZEx - Flame-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Suffix)

cCSAus - Class I, Groups A, B, C and D


SLD Functional Safety Loop HP Housing in
Class II, Groups E, F and G; Class III; Type 4X, IP66 Get Certificate Not Applicable
Display BH or SB Enclosure (CEC-Canada & NEC-USA Approvals, CSA)

cCSAus - General (Ordinary) Locations


SPA Site-Programmable Alarm DIN Housing (CEC-Canada & NEC-USA Approvals, CSA)
Get Certificate Not Applicable

FM - Non-Incendive: Class I, Division 2, Groups A, B, C, D


SPA Site-Programmable Alarm DIN Housing (NEC-USA Approvals, FM)
Get Certificate Not Applicable

SPA2 Site- and PC- cFMus - Non-Incendive: Class I, Division 2, Groups A, B, C, D


DIN Housing Get Certificate Not Applicable
Programmable Alarm (CEC-Canada & NEC-USA Approvals, FM)

SPA2IS Site- and PC- IECEx - Non-sparking with Intrinsically Safe Field Connections Get Intrinsically
Programmable Alarm with Ex nA [ia Ga] IIC T4 Gc
DIN Housing Get Certificate Safe Installation
Intrinsically-Safe Field [Ex ia Ga] IIC
(IECEx Approvals, FM) Diagram
Connections

SPA2IS Site- and PC- ATEX - Intrinsically Safe Field Connections


II (1) G [Ex ia Ga] IIC Get Intrinsically
Programmable Alarm with
DIN Housing Non-sparking with Intrinsically Safe Field Connections Get Certificate Safe Installation
Intrinsically-Safe Field II 3(1) G Ex nA [ia Ga] IIC T4 Gc Ta = -40°C to +85°C Diagram
Connections (ATEX - European Union Approvals, FM)

cFMus - Associated Apparatus providing I.S. (Entity) connections to


Class I, II, III Division 1 Groups A-G
SPA2IS Site- and PC- AIS / I, II, III / 1 / A-G Get Intrinsically
Programmable Alarm with Nonincendive Apparatus for use in Class I, Division 2, Groups A-D
DIN Housing Get Certificate Safe Installation
Intrinsically-Safe Field NI / I / 2 / ABCD / T4 Ta = -40°c to +85°C
Non-sparking Apparatus for use in Class I, Zone 2 Group IIC providing Diagram
Connections
I.S. (Entity) connections to Class I, Zone 0 Group IIC
I / 2 / AEx Na [ia] / IIC / T4 Ta = -40°C to +85°C

cCSAus - General Locations & Non-Incendive:


Class I, Div 2, Groups Groups A-D
SPD Programmable Field-Mount
FH Housing Class II, Div. 2, Groups F & G Get Certificate Not Applicable
Loop Display Class III, Divisions 1 & 2; T5@85°C / T6@60°C, Type 4X, IP66
(CEC-Canada & NEC-USA Approvals, CSA)

SPT Site-Programmable FM - Non-Incendive: Class I, Division 2, Groups A, B, C, D


DIN Housing Get Certificate Not Applicable
Transmitter (NEC-USA Approvals, FM)

SPT Site-Programmable sCSAus - General (Ordinary) Locations


DIN Housing Get Certificate Not Applicable
Transmitter (CEC-Canada & NEC-USA Approvals, CSA)

cULus - Listed Apparatus: General/Ordinary Locations


SRM DIN Housing (CEC-Canada & NEC-USA Approvals, UL)
Get Certificate Not Applicable

Standard Housing in CSA - General (Ordinary) Locations & Explosion-Proof


SRT Square Root Transmitter Consult Factory Not Applicable
EX or EXUL Enclosure (CEC-Canada Approvals, CSA)

Moore Industries-International, Inc. Page 18 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

cFMus - Non-Incendive: Class I, Division 2, Groups A, B, C and D


SST HART Safety Series
DIN Housing Temperature Class T4, Tamb = -40°C to +85°C Get Certificate Not Applicable
Isolator and Spliitter (CEC-Canada & NEC-USA Approvals, FM)

cFMus - Non-Incendive: Class I, Division 2, Groups A, B, C and D


SSX HART Safety Series
DIN Housing Temperature Class T4, Tamb = -40°C to +85°C Get Certificate Not Applicable
Isolator (CEC-Canada & NEC-USA Approvals, FM)

cCSAus - Non-Incendive: Class I, Division 2, Groups A, B, C, D


STA Safety Trip Alarm DIN Housing (CEC-Canada & NEC-USA Approvals, CSA)
Get Certificate Not Applicable

cFMus - Intrinsically Safe: Class I, Division 1, Groups A, B, C, D


STZ Functional Safety Dual Class I, Zone 0, AEx ia IIC; Get Intrinsically
Non-Incendive: Class I, Division 2, Groups A, B, C, D
Input Smart HART Temperature HP Housing Non-sparking: Class I, Zone 2, AEx nA IIC;
Get Certificate Safe Installation
Transmitter Temperature Code: T4@85°C Max. Op. Ambient Diagram
(CEC-Canada & NEC-USA Approvals, FM)

STZ Functional Safety Dual Get Intrinsically


ATEX - Intrinsically Safe: II 1G Ex ia IIC T4@85°C
Input Smart HART Temperature HP Housing (ATEX - European Union Approvals, FM)
Get Certificate Safe Installation
Transmitter Diagram

STZ Functional Safety Dual


ATEX - Non-Sparking: II 3G Ex nA IIC T4@85°C
Input Smart HART Temperature HP Housing (ATEX - European Union Approvals, FM)
Get Certificate Not Applicable
Transmitter

STZ Functional Safety Dual IECEx - Intrinsically Safe: Ex ia IIC T4@85°C Get Intrinsically
Input Smart HART Temperature HP Housing Non-Sparking: Ex nA IIC T4@85°C Get Certificate Safe Installation
Transmitter (IECEx Approvals, FM) Diagram

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


STZ Functional Safety Dual Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
HP Housing in
Input Smart HART Temperature Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
BH Enclosure Environmental Protection: NEMA 4X & IP66
Transmitter
(NEC-USA Approvals, FM)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


STZ Functional Safety Dual Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
HP Housing in
Input Smart HART Temperature Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
SB Enclosure Environmental Protection: NEMA 4X & IP66
Transmitter
(NEC-USA Approvals, FM)

STZ Functional Safety Dual HP Housing in BH or


Input Smart HART Temperature SB Enclosure (with "A" ANZEx ANZEx - Flame/Explosion-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Transmitter Enclosure Suffix)

STZ Functional Safety Dual cCSAus - Class I, Groups A, B, C and D


HP Housing in
Input Smart HART Temperature Class II, Groups E, F and G; Class III; Type 4X, IP66 Get Certificate Not Applicable
BH or SB Enclosure (CEC-Canada & NEC-USA Approvals, CSA)
Transmitter

STZ Functional Safety Dual HP Housing in BH or ATEX - Flame Proof: II 2G Ex d IIC T6 Gb


Input Smart HART Temperature SB Enclosure (with "E" Dust Ignition Protection: II 2D Ex tb IIIC Db T85°C IP66 Get Certificate Not Applicable
Transmitter Enclosure Suffix) (ATEX - European Union Approvals, ISSeP)

Moore Industries-International, Inc. Page 19 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

cFMus - Intrinsically Safe: Class I, Division 1, Groups A, B, C, D


STZ Functional Safety Dual Class I, Zone 0, AEx ia IIC; Get Intrinsically
Non-Incendive: Class I, Division 2, Groups A, B, C, D
Input Smart HART Temperature HPP Housing Non-sparking: Class I, Zone 2, AEx nA IIC;
Get Certificate Safe Installation
Transmitter Temperature Code: T4@85°C; T5@85°C; T6@60°C Diagram
(CEC-Canada & NEC-USA Approvals, FM)

STZ Functional Safety Dual ATEX - Non-Sparking: II 3G Ex nA IIC;


Input Smart HART Temperature HPP Housing Temperature Code: T4@85°C; T5@85°C; T6@60°C Get Certificate Not Applicable
Transmitter (ATEX - European Union Approvals, FM)

STZ Functional Safety Dual ATEX - Intrinsically Safe: II 1G Ex ia IIC; Get Intrinsically
Input Smart HART Temperature HPP Housing Temperature Code: T4@85°C; T5@85°C; T6@60°C Get Certificate Safe Installation
Transmitter (ATEX - European Union Approvals, FM) Diagram

STZ Functional Safety Dual IECEx - Intrinsically Safe: Ex ia IIC Ga; Get Intrinsically
Non-Sparking: Ex nA IIC Gc;
Input Smart HART Temperature HPP Housing Temperature Code: T4@85°C; T5@85°C; T6@60°C
Get Certificate Safe Installation
Transmitter (IECEx Approvals, FM) Diagram

STZ Functional Safety Dual cCSAus - Class I, Groups A, B, C and D


HPP Housing in
Input Smart HART Temperature Class II, Groups E, F and G; Class III; IP66 Get Certificate Not Applicable
LH2 Enclosure (CEC-Canada & NEC-USA Approvals, CSA)
Transmitter

HPP Housing in LH2


STZ Functional Safety Dual
Enclosure, Solid Cover
Input Smart HART Temperature
(with "A" Enclosure ANZEx ANZEx - Flame-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Transmitter
Suffix)

STZ Functional Safety Dual HPP Housing in LH2 ATEX - Flame Proof: II 2G Ex d IIC T6 Gb
Input Smart HART Temperature Enclosure (with "E" Dust Ignition Protection: II 2D Ex tb IIIC Db T85°C IP66 Get Certificate Not Applicable
Transmitter Enclosure Suffix) (ATEX - European Union Approvals, ISSeP)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


STZ Functional Safety Dual Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
HPP Housing in
Input Smart HART Temperature Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
LH2 Enclosure Environmental Protection: NEMA 4X & IP66
Transmitter
(NEC-USA Approvals, FM)

STZ Functional Safety Dual


cFMus - Non-Incendive: Class I, Division 2, Groups A, B, C, D
Input Smart HART Temperature DIN Housing (CEC-Canada & NEC-USA Approvals, FM)
Get Certificate Not Applicable
Transmitter

cFMus - Associated Apparatus providing I.S. (Entity) connections to


Class I, II, III Division 1 Groups A-G
Associated Apparatus providing I.S. (Entity) connections to
Class 1, Zone 0 Group IIC
STZ Functional Safety Dual [AEx ia Ga] II C / [Ex ia] IIC Get Intrinsically
DIN Housing Nonincendive for use in Class I Division 2 Groups A-D providing I.S. (Entity)
Input Smart HART Temperature Get Certificate Safe Installation
(with -AIS Option) connections to Class I, II, III Division 1 Groups A-G
Transmitter Non-Sparking Apparatus for use in Class I, Zone 2 providiing I.S. (Entity) Diagram
connections to Class I Zone 0 Group IIC
Class I, Zone 2, AEx nA [ia Ga] IIC T4 Gc / Ex nA [ia Gc] IIC T4 Gc
Tamb = -40°C to +85°C
(CEC-Canada & NEC-USA Approvals FM)

ATEX - Associated Apparatus providing I.S. field connections


STZ Functional Safety Dual II (1) G [Ex ia Ga] IIC; Tamb = -40°C to +85°C Get Intrinsically
DIN Housing
Input Smart HART Temperature Non-Sparking Associated Apparatus providing I.S. field connections Get Certificate Safe Installation
(with -AIS Option) II 3(1) G Ex nA [ia Ga] IIC T4 Gc; Tamb = -40°C to +85°C
Transmitter Diagram
(ATEX - European Union Approvals, FM)

IECEx - Associated Apparatus providing I.S. field connections


STZ Functional Safety Dual [Ex ia Ga] IIC Get Intrinsically
DIN Housing Non-Sparking Associated Apparatus providing I.S. field connections
Input Smart HART Temperature Get Certificate Safe Installation
(with -AIS Option) Ex nA [ia Ga] IIC Gc
Transmitter Tamb = -40°C to +85°C Diagram
(IECEx Approvals, FM)

Moore Industries-International, Inc. Page 20 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

Get Intrinsically
T2X Non-Isolated RTD HPP Housing ATEX - Intrinsically Safe: II 2G EEx ib IIB, T6@60°C
Consult Factory Safe Installation
Transmitter (with -ISE Option) (ATEX - European Union Approvals, LCIE)
Diagram

FM - Intrinsically Safe: Class I, Division 1, Groups A, B, C & D T6


Class I, Zone 0, AEx ia IIC T6 Ga Get Intrinsically
T2X Non-Isolated RTD
HPP Housing Non-Incendive: Class I, Division 2, Groups A, B, C & D T6 Get Certificate Safe Installation
Transmitter Temperature Code: T6@60°C Maximum Operating Ambient Diagram
(NEC-USA Approvals, FM)

cCSAus - Class I, Groups A, B, C and D Get Intrinsically


T2X Non-Isolated RTD HPP Housing in
Class II, Groups E, F and G; Class III; IP66 Get Certificate Safe Installation
Transmitter LH2 Enclosure (CEC-Canada & NEC-USA Approvals, CSA) Diagram

HPP Housing in LH2 ATEX - Flame Proof: II 2G Ex d IIC T6 Gb Get Intrinsically


T2X Non-Isolated RTD
Enclosure (with "E" Dust Ignition Protection: II 2D Ex tb IIIC Db T85°C IP66 Get Certificate Safe Installation
Transmitter (ATEX - European Union Approvals, ISSeP)
Enclosure Suffix) Diagram

CSA - Intrinsically Safe & Non Incendive Get Intrinsically


T2X Non-Isolated RTD HPP Housing
Class I, Divisions 1 & 2, Groups A-D, T6@60°C Get Certificate Safe Installation
Transmitter (with -ISC Option) (CEC-Canada Approvals, CSA) Diagram

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
T2X Non-Isolated RTD HPP Housing in
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
Transmitter LH2 Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

HPP Housing in LH2


T2X Non-Isolated RTD Enclosure, Solid Cover
Transmitter (with "A" Enclosure ANZEx ANZEx - Flame-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Suffix)

Standard Housing
CSA - General (Ordinary) Locations & Explosion-Proof
TCA Thermocouple Alarm in (CEC-Canada Approvals, CSA)
Consult Factory Not Applicable
EX or EXUL Enclosure

cFMus - Intrinsically Safe: Class I, Divisions 1, Groups A, B, C, D


Temperature Class: T4@ -40°C to 85°C; T5 @ -40°C to 40°C Get Intrinsically
TCM Temperature Concentrator
DIN Housing Non-Incendive: Class I, Division 2, Groups A, B, C, D Get Certificate Safe Installation
Module (TCS) Temperature Code: T4@ -40°C to 40°C Diagram
(CEC-Canada & NEC-USA Approvals, FM)

IECEx - Intrinsically Safe: Ex ia IIC T4 Ga Get Intrinsically


TCM Temperature Concentrator Non-Sparking [Limited Energy]: Ex nA [nL] IIC T4 Gc
DIN Housing Get Certificate Safe Installation
Module (TCS) Ta = -40°C to 85°C
(IECEx Approvals, FM) Diagram

Get Intrinsically
TCM Temperature Concentrator ATEX - Intrinsically Safe: II 1G Ex ia IIC, T4@85°C; T5@40°C
DIN Housing Get Certificate Safe Installation
Module (TCS) (ATEX - European Union Approvals, FM)
Diagram

TCM Temperature Concentrator ATEX - Non-Sparking: II 3G Ex nA IIC, T4@85°C; T5@40°C


DIN Housing Consult Factory Not Applicable
Module (TCS) (ATEX - European Union Approvals, MII)

Standard Housing in CSA - General (Ordinary) Locations & Explosion-Proof


TCT Thermocouple Transmitter Consult Factory Not Applicable
EX or EXUL Enclosure (CEC-Canada Approvals, CSA)

CSA - General (Ordinary) Locations


TCX Thermocouple Transmitter DIN or HP Housing (CEC-Canada Approvals, CSA)
Consult Factory Not Applicable

Moore Industries-International, Inc. Page 21 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

HP Housing in 2HS, CSA - Explosion-Proof: Class I, Division 1, Groups B, C, D


TCX Thermocouple Transmitter 2LS, 3HS or 3LS Class II, Division 1, Groups E, F, G: Class III Get Certificate Not Applicable
Enclosure (CEC-Canada Approvals, CSA)

HP Housing in 2HS, FM - Explosion-Proof: Class I, Division 1, Groups B, C, D


Dust Ignition-Proof: Class II, Division 1, Groups E, F, G
TCX Thermocouple Transmitter 2LS, 3HS or 3LS Suitable for use in: Class III, Division 1
Get Certificate Not Applicable
Enclosure (NEC-USA Approvals, FM)

TDA DIN-Style Thermocouple CSA - General (Ordinary) Locations


DIN Housing Consult Factory Not Applicable
Alarm (CEC-Canada Approvals, CSA)

TDY PC-Programmable ATEX - Intrinsically Safe: II 1G Ex ia IIC T4 Ga Get Intrinsically


HP Housing
Temperature Transmitter with Tamb = -40°C to +85°C Get Certificate Safe Installation
(-IS Option Required) (ATEX - European Union Approvals, FM)
Display Diagram

TDY PC-Programmable FM - Intrinsically Safe: Class I, Division 1, Groups A, B, C & D Get Intrinsically
HP Housing Class I, Zone 0, AEx ia IIC T4
Temperature Transmitter with Get Certificate Safe Installation
(-IS Option Required) Temperature Class: T4 Tamb = -40°C to +85°C
Display (CEC-Canada & NEC-USA Approvals, FM) Diagram

TDY PC-Programmable IECEx - Intrinsically Safe: Ex ia IIC T4 Ga Get Intrinsically


HP Housing
Temperature Transmitter with Tamb = -40°C to +85°C Get Certificate Safe Installation
(-IS Option Required) (IECEx Approvals, FM)
Display Diagram

TDY PC-Programmable ATEX - Non-Sparking: II 3G Ex nA IIC T4 Ga


Temperature Transmitter with HP Housing Tamb = -40°C to +85°C Get Certificate Not Applicable
Display (ATEX - European Union Approvals, FM)

TDY PC-Programmable FM - Non-Incendive: Class I, Division 2, Groups A, B, C & D


Class I, Zone 2, AEx nA IIC T4
Temperature Transmitter with HP Housing Temperature Class: T4 Tamb = -40°C to +85°C
Get Certificate Not Applicable
Display (CEC-Canada & NEC-USA Approvals, FM)

TDY PC-Programmable IECEx - Non-Sparking: Ex nA IIC T4 Ga


Temperature Transmitter with HP Housing Tamb = -40°C to +85°C Get Certificate Not Applicable
Display (IECEx Approvals, FM)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


TDY PC-Programmable Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
HP Housing in
Temperature Transmitter with Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
BH Enclosure Environmental Protection: NEMA 4X & IP66
Display
(NEC-USA Approvals, FM)

TDY PC-Programmable HP Housing in BH or


Temperature Transmitter with SB Enclosure (with "A" ANZEx ANZEx - Flame-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Display Enclosure Suffix)

TDY PC-Programmable HP Housing in BH or ATEX - Flame Proof: II 2G Ex d IIC T6 Gb


Temperature Transmitter with SB Enclosure (with "E" Dust Ignition Protection: II 2D Ex tb IIIC Db T85°C IP66 Get Certificate Not Applicable
Display Enclosure Suffix) (ATEX - European Union Approvals, ISSeP)

Moore Industries-International, Inc. Page 22 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

TDY PC-Programmable cCSAus - Class I, Groups A, B, C and D;


HP Housing in
Temperature Transmitter with Class II, Groups E, F and G; Class III; Type 4X, IP66 Get Certificate Not Applicable
BH or SB Enclosure (CEC-Canada & NEC-USA Approvals, CSA)
Display

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


TDY PC-Programmable Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
HP Housing in
Temperature Transmitter with Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
SB Enclosure Environmental Protection: NEMA 4X & IP66
Display
(NEC-USA Approvals, FM)

cFMus - Intrinsically Safe: Class I, Division 1, Groups A, B, C, D


TDZ2 Smart HART Class I, Zone 0, AEx ia IIC; Get Intrinsically
Temperature Transmitter with HP Housing Non-Incendive: Class I, Division 2, Groups A, B, C, D Get Certificate Safe Installation
Display Temperature Code: T4@85°C Max. Op. Ambient Diagram
(CEC-Canada & NEC-USA Approvals, FM)

TDZ2 Smart HART IECEx - Intrinsically Safe: Ex ia IIC Ga; Get Intrinsically
Non-Sparking: Ex nA IIC Gc;
Temperature Transmitter with HP Housing Temperature Code: T4@85°C
Get Certificate Safe Installation
Display (IECEx Approvals, FM) Diagram

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


TDZ2 Smart HART Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
HP Housing in
Temperature Transmitter with Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
BH Enclosure Environmental Protection: NEMA 4X & IP66
Display
(NEC-USA Approvals, FM)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


TDZ2 Smart HART Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
HP Housing in
Temperature Transmitter with Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
SB Enclosure Environmental Protection: NEMA 4X & IP66
Display
(NEC-USA Approvals, FM)

TDZ2 Smart HART HP Housing in BH or


Temperature Transmitter with SB Enclosure (with "A" ANZEx ANZEx - Flame/Explosion-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Display Enclosure Suffix)

TDZ2 Smart HART cCSAus - Class I, Groups A, B, C and D


HP Housing in
Temperature Transmitter with Class II, Groups E, F and G; Class III; Type 4X, IP66 Get Certificate Not Applicable
BH or SB Enclosure (CEC-Canada & NEC-USA Approvals, CSA)
Display

TDZ2 Smart HART HP Housing in BH or ATEX - Flame Proof: II 2G Ex d IIC T6 Gb


Temperature Transmitter with SB Enclosure (with "E" Dust Ignition Protection: II 2D Ex tb IIIC Db T85°C IP66 Get Certificate Not Applicable
Display Enclosure Suffix) (ATEX - European Union Approvals, ISSeP)

cFMus - Intrinsically Safe: Class I, Division 1, Groups A, B, C, D


Class I, Zone 0, AEx ia IIC; Get Intrinsically
TDZ3 Dual Input Smart HART Non-Incendive: Class I, Division 2, Groups A, B, C, D
HP Housing Get Certificate Safe Installation
Temperature Transmitter Non-sparking: Class I, Zone 2, AEx nA IIC;
Temperature Code: T4@85°C Max. Op. Ambient Diagram
(CEC-Canada & NEC-USA Approvals, FM)

Get Intrinsically
TDZ3 Dual Input Smart HART ATEX - Intrinsically Safe: II 1G Ex ia IIC T4@85°C
HP Housing Get Certificate Safe Installation
Temperature Transmitter (ATEX - European Union Approvals, FM)
Diagram

Moore Industries-International, Inc. Page 23 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

TDZ3 Dual Input Smart HART ATEX - Non-Sparking: II 3G Ex nA IIC T4@85°C


HP Housing Get Certificate Not Applicable
Temperature Transmitter (ATEX - European Union Approvals, FM)

IECEx - Intrinsically Safe: Ex ia IIC T4@85°C Get Intrinsically


TDZ3 Dual Input Smart HART
HP Housing Non-Sparking: Ex nA IIC T4@85°C Get Certificate Safe Installation
Temperature Transmitter (IECEx Approvals, FM) Diagram

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
TDZ3 Dual Input Smart HART HP Housing in
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
Temperature Transmitter BH Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
TDZ3 Dual Input Smart HART HP Housing in
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
Temperature Transmitter SB Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

HP Housing in BH or
TDZ3 Dual Input Smart HART
Temperature Transmitter
SB Enclosure (with "A" ANZEx ANZEx - Flame/Explosion-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Enclosure Suffix)

cCSAus - Class I, Groups A, B, C and D


TDZ3 Dual Input Smart HART HP Housing in
Class II, Groups E, F and G; Class III; Type 4X, IP66 Get Certificate Not Applicable
Temperature Transmitter BH or SB Enclosure (CEC-Canada & NEC-USA Approvals, CSA)

HP Housing in BH or ATEX - Flame Proof: II 2G Ex d IIC T6 Gb


TDZ3 Dual Input Smart HART
SB Enclosure (with "E" Dust Ignition Protection: II 2D Ex tb IIIC Db T85°C IP66 Get Certificate Not Applicable
Temperature Transmitter (ATEX - European Union Approvals, ISSeP)
Enclosure Suffix)

cFMus - Intrinsically Safe: Class I, Division 1, Groups A, B, C, D


TFZ Programmable Class I, Zone 0, AEx ia IIC Get Intrinsically
FOUNDATION Fieldbus HP Housing Non-Incendive: Class I, Division 2, Groups A, B, C, D Get Certificate Safe Installation
Temperature Transmitter Temperature Code: T4@85°C Max. Op. Ambient Diagram
(CEC-Canada & NEC-USA Approvals, FM)

TFZ Programmable
FOUNDATION Fieldbus HP Housing FOUNDATION Fieldbus Device Registration Get Certificate Not Applicable
Temperature Transmitter

TFZ Programmable IECEx - Intrinsically Safe: Ex ia IIC Ga T4@85°C Get Intrinsically


FOUNDATION Fieldbus HP Housing Non-Sparking and Limited Energy: Ex nA nL IIC T4@85°C Get Certificate Safe Installation
Temperature Transmitter (IECEx Approvals, FM) Diagram

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


TFZ Programmable Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
HP Housing in
FOUNDATION Fieldbus Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
BH Enclosure Environmental Protection: NEMA 4X & IP66
Temperature Transmitter
(NEC-USA Approvals, FM)

TFZ Programmable HP Housing in BH or


FOUNDATION Fieldbus SB Enclosure (with "A" ANZEx ANZEx - Flame/Explosion-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Temperature Transmitter Enclosure Suffix)

Moore Industries-International, Inc. Page 24 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

TFZ Programmable HP Housing in BH or ATEX - Flame Proof: II 2G Ex d IIC T6 Gb


FOUNDATION Fieldbus SB Enclosure (with "E" Dust Ignition Protection: II 2D Ex tb IIIC Db T85°C IP66 Get Certificate Not Applicable
Temperature Transmitter Enclosure Suffix) (ATEX - European Union Approvals, ISSeP)

TFZ Programmable cCSAus - Class I, Groups A, B, C and D


HP Housing in
FOUNDATION Fieldbus Class II, Groups E, F and G; Class III; Type 4X, IP66 Get Certificate Not Applicable
BH or SB Enclosure (CEC-Canada & NEC-USA Approvals, CSA)
Temperature Transmitter

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


TFZ Programmable Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
HP Housing in
FOUNDATION Fieldbus Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
SB Enclosure Environmental Protection: NEMA 4X & IP66
Temperature Transmitter
(NEC-USA Approvals, FM)

TG200 TRUNKGUARD Series


Standard (-ATEX ATEX - Type n and Intrinscally Safe Outputs: II 3 G Ex nA [ic] IIC, T5@70°C Get ATEX Field
Fieldbus Device Couplers, Get Certificate
Option Required) (ATEX European Union Approvals, MII) Wiring Diagram
MooreHawke

TG200 TRUNKGUARD Series cFMus - Non-Incendive: Class I, Division 2, Groups A, B, C, D Get FM Non-
Associated Non-Incendive: Class I, Division 2, Groups A - D
Fieldbus Device Couplers, Standard Temperature Code: T5@70°C Max. Op. Ambient
Get Certificate Incendive Field
MooreHawke (CEC-Canada & NEC-USA Approvals, FM) Wiring Diagram

TG200 TRUNKGUARD Series IECEx - Non-Sparking [Limited Energy]: Ex nA [nL] IIC T5


Ta = -40°C to +70°C
Fieldbus Device Couplers, Standard (IECEx Approvals, SIRA)
Get Certificate Not Applicable
MooreHawke

TG200 TRUNKGUARD Series


Fieldbus Foundation- Device Coupler Registration
Fieldbus Device Couplers, Standard Get Certificate Not Applicable
MooreHawke

TG300 TRUNKGUARD Series ATEX - Encapsulation and Increased Safety:


Get ATEX Field
Fieldbus Device Couplers, Standard II 2GD EEx me II, T5@70°C Get Certificate
(ATEX - European Union Approvals, SIRA) Wiring Diagram
MooreHawke

TG300 TRUNKGUARD Series


Fieldbus Foundation- Device Coupler Registration
Fieldbus Device Couplers, Standard Get Certificate Not Applicable
MooreHawke

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
Environmental Protection: NEMA Type 4X & IP66
Intrinsically Safe: Class I, II & III, Division 1, Groups A - G Get Intrinsically
THZ Smart HART Temperature DH
Intrinsically Safe: Class I Zone 0 AEx ia IIC Get Certificate Safe Installation
Transmitters (with ISF Option) Non-Incendive: Class I, Division 2, Groups A, B, C, D Diagram
Suitable for use in: Class II & III, Division 2, Groups F, G
Temperature Code: T4@60°C Max. Op. Ambient
(NEC-USA Approvals, FM)

CSA - Non-Incendive: Class I, Division 2, Groups A, B, C, D


THZ Smart HART Temperature
DIN Housing Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
Transmitters (CEC-Canada Approvals, CSA)

FM - Non-Incendive: Class I, Division 2, Groups A, B, C, D


THZ Smart HART Temperature Suitable for use in: Class II & III, Division 2, Groups F, G
DIN Housing Get Certificate Not Applicable
Transmitters Temperature Code: T6@60°C Maximum Operating Ambient
(NEC-USA Approvals, FM)

Moore Industries-International, Inc. Page 25 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

cFMus - Intrinsically Safe: Class I, Division 1, Groups A, B, C, D


Class I, Zone 0, AEx ia IIC; Get Intrinsically
THZ2 Smart HART
HPP Housing Non-Incendive: Class I, Division 2, Groups A, B, C, D Get Certificate Safe Installation
Temperature Transmitter Temperature Code: T5@85°C; T6@60°C Diagram
(CEC-Canada & NEC-USA Approvals, FM)

IECEx - Intrinsically Safe: Ex ia IIC, T5@85°C, T6@60°C Get Intrinsically


THZ2 Smart HART
HPP Housing Non-Sparking: Ex nA IIC T5@85°C, T6@60°C Get Certificate Safe Installation
Temperature Transmitter (IECEx Approvals, FM) Diagram

cCSAus - Class I, Groups A, B, C and D


THZ2 Smart HART HPP Housing in
Class II, Groups E, F and G; Class III; IP66 Get Certificate Not Applicable
Temperature Transmitter LH2 Enclosure (CEC-Canada & NEC-USA Approvals, CSA)

HPP Housing in LH2


THZ2 Smart HART Enclosure, Solid Cover
Temperature Transmitter (with "A" Enclosure ANZEx ANZEx - Flame-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Suffix)

HPP Housing in LH2 ATEX - Flame Proof: II 2G Ex d IIC T6 Gb


THZ2 Smart HART
Enclosure (with "E" Dust Ignition Protection: II 2D Ex tb IIIC Db T85°C IP66 Get Certificate Not Applicable
Temperature Transmitter (ATEX - European Union Approvals, ISSeP)
Enclosure Suffix)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
THZ2 Smart HART HPP Housing in
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
Temperature Transmitter LH2 Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

cFMus - Intrinsically Safe: Class I, Division 1, Groups A, B, C, D


Class I, Zone 0, AEx ia IIC; Get Intrinsically
THZ3 Dual Input Smart HART Non-Incendive: Class I, Division 2, Groups A, B, C, D
HPP Housing Get Certificate Safe Installation
Temperature Transmitter Non-sparking: Class I, Zone 2, AEx nA IIC;
Temperature Code: T4@85°C; T5@85°C; T6@60°C Diagram
(CEC-Canada & NEC-USA Approvals, FM)

ATEX - Non-Sparking: II 3G Ex nA IIC;


THZ3 Dual Input Smart HART
HPP Housing Temperature Code: T4@85°C; T5@85°C; T6@60°C Get Certificate Not Applicable
Temperature Transmitter (ATEX - European Union Approvals, FM)

ATEX - Intrinsically Safe: II 1G Ex ia IIC; Get Intrinsically


THZ3 Dual Input Smart HART
HPP Housing Temperature Code: T4@85°C; T5@85°C; T6@60°C Get Certificate Safe Installation
Temperature Transmitter (ATEX - European Union Approvals, FM) Diagram

IECEx - Intrinsically Safe: Ex ia IIC Ga; Get Intrinsically


THZ3 Dual Input Smart HART Non-Sparking: Ex nA IIC Gc;
HPP Housing Get Certificate Safe Installation
Temperature Transmitter Temperature Code: T4@85°C; T5@85°C; T6@60°C
(IECEx Approvals, FM) Diagram

cCSAus - Class I, Groups A, B, C and D


THZ3 Dual Input Smart HART HPP Housing in
Class II, Groups E, F and G; Class III; IP66 Get Certificate Not Applicable
Temperature Transmitter LH2 Enclosure (CEC-Canada & NEC-USA Approvals, CSA)

HPP Housing in LH2


THZ3 Dual Input Smart HART Enclosure, Solid Cover
Temperature Transmitter (with "A" Enclosure ANZEx ANZEx - Flame-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Suffix)

Moore Industries-International, Inc. Page 26 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

HPP Housing in LH2 ATEX - Flame Proof: II 2G Ex d IIC T6 Gb


THZ3 Dual Input Smart HART
Enclosure (with "E" Dust Ignition Protection: II 2D Ex tb IIIC Db T85°C IP66 Get Certificate Not Applicable
Temperature Transmitter (ATEX - European Union Approvals, ISSeP)
Enclosure Suffix)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
THZ3 Dual Input Smart HART HPP Housing in
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
Temperature Transmitter LH2 Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

THZ3 Dual Input Smart HART cFMus - Non-Incendive: Class I, Division 2, Groups A, B, C, D
DIN Housing Get Certificate Not Applicable
Temperature Transmitter (CEC-Canada & NEC-USA Approvals, FM)

cFMus - Associated Apparatus providing I.S. (Entity) connections to


Class I, II, III Division 1 Groups A-G
Associated Apparatus providing I.S. (Entity) connections to
Class 1, Zone 0 Group IIC
[AEx ia Ga] II C / [Ex ia] IIC Get Intrinsically
THZ3 Dual Input Smart HART DIN Housing Nonincendive for use in Class I Division 2 Groups A-D providing I.S. (Entity)
Get Certificate Safe Installation
Temperature Transmitter (with -AIS Option) connections to Class I, II, III Division 1 Groups A-G
Non-Sparking Apparatus for use in Class I, Zone 2 providiing I.S. (Entity) Diagram
connections to Class I Zone 0 Group IIC
Class I, Zone 2, AEx nA [ia Ga] IIC T4 Gc / Ex nA [ia Gc] IIC T4 Gc
Tamb = -40°C to +85°C
(CEC-Canada & NEC-USA Approvals FM)

ATEX - Associated Apparatus providing I.S. field connections


II (1) G [Ex ia Ga] IIC; Tamb = -40°C to +85°C Get Intrinsically
THZ3 Dual Input Smart HART DIN Housing
Non-Sparking Associated Apparatus providing I.S. field connections Get Certificate Safe Installation
Temperature Transmitter (with -AIS Option) II 3(1) G Ex nA [ia Ga] IIC T4 Gc; Tamb = -40°C to +85°C Diagram
(ATEX - European Union Approvals, FM)

IECEx - Associated Apparatus providing I.S. field connections


[Ex ia Ga] IIC Get Intrinsically
THZ3 Dual Input Smart HART DIN Housing Non-Sparking Associated Apparatus providing I.S. field connections
Get Certificate Safe Installation
Temperature Transmitter (with -AIS Option) Ex nA [ia Ga] IIC Gc
Tamb = -40°C to +85°C Diagram
(IECEx Approvals, FM)

TIY Site-Programmable CSA - General (Ordinary) Locations


DIN or HP Housing Consult Factory Not Applicable
Thermocouple Transmitter (CEC-Canada Approvals, CSA)

TIY Site-Programmable FM - Non-Incendive: Class I, Division 2, Groups A, B, C, D


DIN or HP Housing Get Certificate Not Applicable
Thermocouple Transmitter (NEC-USA Approvals, FM)

Get Intrinsically
TIY Site-Programmable HP Housing CSA - Intrinsically Safe: Class I, Groups A, B, C, D
Get Certificate Safe Installation
Thermocouple Transmitter (with -ISC Option) (CEC-Canada Approvals, CSA)
Diagram

HP Housing in 2HS, FM - Explosion-Proof: Class I, Division 1, Groups B, C, D


TIY Site-Programmable Dust Ignition-Proof: Class II, Division 1, Groups E, F, G
2LS, 3HS or 3LS Get Certificate Not Applicable
Thermocouple Transmitter Suitable for use in: Class III, Division 1
Enclosure (NEC-USA Approvals, FM)

HP Housing in 2HS, CSA - Explosion-Proof: Class I, Groups B, C, D


TIY Site-Programmable
2LS, 3HS or 3LS Class II, Groups E, F, G; Class III Get Certificate Not Applicable
Thermocouple Transmitter (CEC-Canada Approvals, CSA)
Enclosure

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
TIY Site-Programmable HP Housing in
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
Thermocouple Transmitter BH Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

HP Housing in BH or
TIY Site-Programmable
Thermocouple Transmitter
SB Enclosure (with "A" ANZEx ANZEx - Flame-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Enclosure Suffix)

Moore Industries-International, Inc. Page 27 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

HP Housing in BH or ATEX - Flame Proof: II 2G Ex d IIC T6 Gb


TIY Site-Programmable
SB Enclosure (with "E" Dust Ignition Protection: II 2D Ex tb IIIC Db T85°C IP66 Get Certificate Not Applicable
Thermocouple Transmitter (ATEX - European Union Approvals, ISSeP)
Enclosure Suffix)

cCSAus - Class I, Groups A, B, C and D


TIY Site-Programmable HP Housing in
Class II, Groups E, F and G; Class III; Type 4X, IP66 Get Certificate Not Applicable
Thermocouple Transmitter BH or SB Enclosure (CEC-Canada & NEC-USA Approvals, CSA)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
TIY Site-Programmable HP Housing in
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
Thermocouple Transmitter SB Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

TPS202 Fieldbus Power


Conditioner Module
Standard Fieldbus Foundation - Power Conditioner Registration Get Certificate Not Applicable
(MooreHawke TPS400 Power
Supply)

TPS400 Advanced Fieldbus


Standard Fieldbus Foundation - Power Conditioner Registration Get Certificate Not Applicable
Power Supply, MooreHawke

cFMus - Intrinsically Safe: Class I, Division 1, Groups A, B, C, D


Class I, Zone 0, AEx ia IIC Get Intrinsically
TPZ Programmable PROFIBUS
HP Housing Non-Incendive: Class I, Division 2, Groups A, B, C, D Get Certificate Safe Installation
PA Transmitter Temperature Code: T4@85°C Max. Op. Ambient Diagram
(CEC-Canada & NEC-USA Approvals, FM)

IECEx - Intrinsically Safe: Ex ia IIC Ga T4@85°C Get Intrinsically


TPZ Programmable PROFIBUS
HP Housing Non-Sparking: Ex nA IIC T4@85°C Get Certificate Safe Installation
PA Transmitter (IECEx Approvals, FM) Diagram

TPZ Programmable PROFIBUS


HP Housing Process Field Bus Registration Get Certificate Not Applicable
PA Transmitter

TPZ Programmable PROFIBUS


HP Housing Siemens AG SIMATIC Process Device Manager Integration Test Get Certificate Not Applicable
PA Transmitter

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
TPZ Programmable PROFIBUS HP Housing in
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
PA Transmitter BH Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

HP Housing in BH or
TPZ Programmable PROFIBUS
PA Transmitter
SB Enclosure (with "A" ANZEx ANZEx - Flame/Explosion-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Enclosure Suffix)

HP Housing in BH or ATEX - Flame Proof: II 2G Ex d IIC T6 Gb


TPZ Programmable PROFIBUS
SB Enclosure (with "E" Dust Ignition Protection: II 2D Ex tb IIIC Db T85°C IP66 Get Certificate Not Applicable
PA Transmitter (ATEX - European Union Approvals, ISSeP)
Enclosure Suffix)

cCSAus - Class I, Groups A, B, C and D


TPZ Programmable PROFIBUS HP Housing in
Class II, Groups E, F and G; Class III; Type 4X, IP66 Get Certificate Not Applicable
PA Transmitter BH or SB Enclosure (CEC-Canada & NEC-USA Approvals, CSA)

Moore Industries-International, Inc. Page 28 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
TPZ Programmable PROFIBUS HP Housing in
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
PA Transmitter SB Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

FM - Intrinsically Safe: Class I, Division 1, Groups A, B, C & D T6


TRX Non-Isolated PC- Class I, Zone 0, AEx ia IIC T6 Ga Get Intrinsically
Programmable Temperature HPP Housing Non-Incendive: Class I, Division 2, Groups A, B, C & D T6 Get Certificate Safe Installation
Transmitter Temperature Code: T6@60°C Maximum Operating Ambient Diagram
(NEC-USA Approvals, FM)

TRX Non-Isolated PC- CSA - Intrinsically Safe & Non Incendive: Get Intrinsically
HPP Housing
Programmable Temperature Class I, Divisions 1 & 2, Groups A-D, T6@60°C Get Certificate Safe Installation
(with -ISC Option) (CEC-Canada Approvals, CSA)
Transmitter Diagram

TRX Non-Isolated PC- Get Intrinsically


HPP Housing ATEX - Intrinsically Safe: II 2G EEx ib IIB, T6@60°C
Programmable Temperature Consult Factory Safe Installation
(with -ISE Option) (ATEX - European Union Approvals, LCIE)
Transmitter Diagram

TRX Non-Isolated PC- Get Intrinsically


HPP Housing
Programmable Temperature
(with -ISA option) ANZEx ANZEx - Intrinsically Safe Ex ia IIC T5 @+85°C
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Safe Installation
Transmitter Diagram

TRX Non-Isolated PC- cCSAus - Class I, Groups A, B, C and D


HPP Housing in
Programmable Temperature Class II, Groups E, F and G; Class III; IP66 Get Certificate Not Applicable
LH2 Enclosure (CEC-Canada & NEC-USA Approvals, CSA)
Transmitter

TRX Non-Isolated PC- HPP Housing in LH2 ATEX - Flame Proof: II 2G Ex d IIC T6 Gb
Programmable Temperature Enclosure (with "E" Dust Ignition Protection: II 2D Ex tb IIIC Db T85C IP66 Get Certificate Not Applicable
Transmitter Enclosure Suffix) (ATEX - European Union Approvals, ISSeP)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


TRX Non-Isolated PC- Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
HPP Housing in
Programmable Temperature Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
LH2 Enclosure Environmental Protection: NEMA 4X & IP66
Transmitter
(NEC-USA Approvals, FM)

HPP Housing in LH2


TRX Non-Isolated PC-
Enclosure, Solid Cover
Programmable Temperature
(with "A" Enclosure ANZEx ANZEx - Flame-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Transmitter
Suffix)

TRY PC-Programmable cCSAus - General (Ordinary) Locations


DIN Housing Get Certificate Not Applicable
Temperature Transmitter (CEC-Canada & NEC-USA Approvals, CSA)

Get Intrinsically
TRY PC-Programmable HPP Housing ATEX - Intrinsically Safe: II 2G EEx ib IIC, T6@60°C
Consult Factory Safe Installation
Temperature Transmitter (with -ISE Option) (ATEX - European Union Approvals, LCIE)
Diagram

FM - Intrinsically Safe: Class I, Division 1, Groups A, B, C & D T6


Class I, Zone 0, AEx ia IIC T6 Ga Get Intrinsically
TRY PC-Programmable
HPP Housing Non-Incendive: Class I, Division 2, Groups A, B, C & D T6 Get Certificate Safe Installation
Temperature Transmitter Temperature Code: T6@60°C Maximum Operating Ambient Diagram
(NEC-USA Approvals, FM)

CSA - Intrinsically Safe & Non Incendive: Get Intrinsically


TRY PC-Programmable HPP Housing
Class I, Divisions 1 & 2, Groups A-D, T6@60°C Get Certificate Safe Installation
Temperature Transmitter (with -ISC Option) (CEC-Canada Approvals, CSA) Diagram

Moore Industries-International, Inc. Page 29 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

Get Intrinsically
TRY PC-Programmable HPP Housing
Temperature Transmitter (with -ISA option) ANZEx ANZEx - Intrinsically Safe Ex ia IIC T5 @+85°C
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Safe Installation
Diagram

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
TRY PC-Programmable HPP Housing in
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
Temperature Transmitter LH2 Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

cCSAus - Class I, Groups A, B, C and D


TRY PC-Programmable HPP Housing in
Class II, Groups E, F and G; Class III; IP66 Get Certificate Not Applicable
Temperature Transmitter LH2 Enclosure (CEC-Canada & NEC-USA Approvals, CSA)

HPP Housing in LH2 ATEX - Flame Proof: II 2G Ex d IIC T6 Gb


TRY PC-Programmable
Enclosure (with "E" Dust Ignition Protection: II 2D Ex tb IIIC Db T85°C IP66 Get Certificate Not Applicable
Temperature Transmitter (ATEX - European Union Approvals, ISSeP)
Enclosure Suffix)

HPP Housing in LH2


TRY PC-Programmable Enclosure, Solid Cover
Temperature Transmitter (with "A" Enclosure ANZEx ANZEx - Flame-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Suffix)

ATEX - Intrinsically Safe: II 1G Ex ia IIC


TRZ Smart HART Temperature HPP Housing
T4@80°C, T5@71°C, T6@56°C Ga Get Certificate Not Applicable
Transmitter (with -ISE Option) (ATEX - European Union Approvals, DEKRA)

IECEx - Intrinsically Safe: Ex ia IIC


TRZ Smart HART Temperature HPP Housing
T4@80°C, T5@71°C, T6@56°C Ga Get Certificate Not Applicable
Transmitter (with -ISE Option) (IECEx Approvals, DEKRA)

FM - Explosion-Proof: Class I, Division 1, Groups A, B, C, D


Dust Ignition-Proof: Class II & III, Division 1, Groups E, F, G
TRZ Smart HART Temperature HPP Housing in
Temperature Code: T6@60°C Maximum Operating Ambient Get Certificate Not Applicable
Transmitter LH2 Enclosure Environmental Protection: NEMA 4X & IP66
(NEC-USA Approvals, FM)

HPP Housing in LH2 ATEX - Flame Proof: II 2G Ex d IIC T6 Gb


TRZ Smart HART Temperature
Enclosure (with "E" Dust Ignition Protection: II 2D Ex tb IIIC Db T85°C IP66 Get Certificate Not Applicable
Transmitter (ATEX - European Union Approvals, ISSeP)
Enclosure Suffix)

HPP Housing in LH2


TRZ Smart HART Temperature Enclosure, Solid Cover
Transmitter (with "A" Enclosure ANZEx ANZEx - Flame-Proof: Ex d IIC T6@60°C, IP66
(ANZEx - Australia & New Zealand Approvals, TestSafe)
Get Certificate Not Applicable
Suffix)

ATEX - Type n and Intrinscally Safe Outputs:


TRUNKSAFE TS200 Series Standard (-ATEX Get ATEX Field
II 3 G Ex nA nC [ic] IIC, T4; Ta = -40°C to 70°C Get Certificate
Device Couplers Option Required) (ATEX - European Union Approvals, MII) Wiring Diagram

cFMus - Non-Incendive: Class I, Division 2, Groups A, B, C, D Get FM Non-


TRUNKSAFE TS200 Series
Standard Temperature Class T4A @ 70°C Get Certificate Incendive Field
Device Couplers (CEC-Canada & NEC-USA Approvals, FM) Wiring Diagram

TRUNKSAFE TS200 Series ATEX - Type n: II 3 G Ex nA nC [nL] IIC T4, Ta = -40°C to 70°C Get ATEX Field
Standard Get Certificate
Device Couplers (ATEX - European Union Approvals, FM) Wiring Diagram

Moore Industries-International, Inc. Page 30 of 31 700-710-108AK


Interface Solution Product Certification Summary

Download Field
Housing Type with Agency Installation
Model Certifications Download Certificate
Options (If Required) Marking Diagram for I.S.
Applications

IECEx - Non-Sparking, Enclosed Break [Limited Energy]:


TRUNKSAFE TS200 Series
Standard Ex nA nC [nL] IIC, -40°C to 70°C Get Certificate Not Applicable
Device Couplers (IECEx Approvals, FM)

cULus - Listed Apparatus:


WNM Wireless Network Module DIN Housing Non-Incendive, Class I, Division 2, Groups A, B, C, D Get Certificate Not Applicable
(CEC-Canada & NEC-USA Approvals, UL)

Moore Industries-International, Inc. Page 31 of 31 700-710-108AK