Professional Documents
Culture Documents
Drift Code "A10" Drift O.D. "217.17 MM Drift Length "162 MM"
Drift Code "A10" Drift O.D. "217.17 MM Drift Length "162 MM"
Item No. Specs according to Warehouse racks Availability of MTC HT No. QC No. Tracing No.
1 2 3 4 Ave. 1 2 3 4 Ave. standard min Judgement
N/A 1 2-1 11.91 12.27 12.60 12.03 12.20 11.44 11.77 11.98 11.64 11.71 Reject
N/A 2 2-2 11.96 11.28 11.63 11.37 11.56 12.11 11.57 11.55 11.90 11.78 Reject
2 Plain end Casing 7" - 32 PPF - TP125 - TPCO Available N/A 3 2-3 12.57 12.23 12.10 11.85 12.19 11.22 11.92 11.08 11.14 11.34 11.51 10.07 Reject
N/A 4 2-4 11.15 12.57 11.51 11.54 11.69 12.30 12.60 11.63 12.22 12.19 Reject
N/A 5 2-5 11.95 11.26 12.11 11.75 11.77 11.89 11.54 11.48 11.16 11.52 Reject
1 3-1 12.70 12.65 12.15 11.97 12.37 12.52 12.09 12.54 11.84 12.25 Reject
2 3-2 11.95 12.17 12.53 12.06 12.18 12.22 12.29 12.11 12.01 12.16 Reject
3 3-3 12.22 11.91 12.51 12.06 12.18 11.74 12.80 12.85 12.50 12.47 Reject
4 3-4 12.36 12.44 12.47 12.62 12.47 12.68 12.52 12.02 11.85 12.27 Reject
5 3-5 12.21 12.62 11.82 12.20 12.21 12.55 12.06 12.96 12.10 12.42 Reject
6 3-6 11.96 12.49 12.23 12.54 12.31 12.36 12.37 12.49 12.03 12.31 Reject
7 3-7 12.95 11.95 12.13 11.86 12.22 11.76 12.28 11.88 12.41 12.08 Accept
9 3-9 12.05 12.05 12.01 12.09 12.05 12.35 12.03 12.39 12.27 12.26 Reject
10 3-10 11.96 12.21 12.06 12.25 12.12 12.03 12.24 11.98 12.16 12.10 Reject
11 3-11 - - - - - - - - - - Reject
12 3-12 - - - - - - - - - - Reject
13 3-13 - - - - - - - - - - Reject
14 3-14 - - - - - - - - - - Reject
15 3-15 - - - - - - - - - - Reject
Marking is deleted 1 4-1-1 9.13 9.80 8.82 9.43 9.30 9.50 9.14 9.40 9.26 9.33
Marking is deleted 2 4-1-2 9.87 9.27 9.71 9.66 9.63 9.24 9.33 9.63 9.42 9.41
Marking is deleted 3 4-1-3 9.27 9.71 9.29 9.10 9.34 9.78 9.63 8.99 8.54 9.24
Marking is deleted 4 4-1-4 9.02 9.67 9.10 9.52 9.33 9.49 9.36 9.47 9.31 9.41
Marking is deleted 5 4-1-5 9.09 9.44 8.55 8.60 8.92 9.09 8.89 9.06 9.26 9.08
Drift Code "X16"
Drift O.D. "157.46 mm
Drift Length "162 mm"
Marking is deleted 6 4-1-6 9.60 9.90 9.30 9.20 9.50 9.04 9.56 9.69 9.61 9.48
Marking is deleted 7 4-1-7 9.65 9.42 9.33 9.25 9.41 9.49 9.41 9.60 9.36 9.47
Marking is deleted 8 4-1-8 8.90 9.80 9.32 9.00 9.26 9.36 9.81 9.26 9.30 9.43
Marking is deleted 9 4-1-9 8.85 8.92 9.68 9.04 9.12 9.50 9.31 9.36 9.50 9.42
Marking is deleted 10 4-1-10 8.87 9.55 8.91 9.53 9.22 9.83 9.03 9.21 9.16 9.31
Marking is deleted 1 4-2-1 9.38 9.67 9.31 9.48 9.46 9.36 9.37 9.53 9.20 9.37 Reject
Marking is deleted 2 4-2-2 9.56 8.95 9.59 9.33 9.36 9.84 9.54 8.72 8.97 9.27 Reject
Marking is deleted 3 4-2-3 9.46 9.80 9.20 9.14 9.40 9.40 8.96 9.59 9.46 9.35 Reject
Marking is deleted 4 4-2-4 9.43 9.66 9.02 9.04 9.29 9.48 8.84 8.91 9.00 9.06 Reject
Green Pipe Casing 7" -26 ppf - Target Grade L80- TPCO
4 Or Available Marking is deleted 5 4-2-5 9.55 9.52 9.06 9.30 9.36 9.04 9.37 9.69 8.91 9.25 Drift Code "X16" Reject
Green Pipe Casing 7” -26ppf – Target Grade N80Q -Dalipal Drift O.D. "157.46 mm
Drift Length "162 mm"
Marking is deleted 6 4-2-6 9.09 8.84 9.30 8.88 9.03 8.93 8.69 8.94 9.01 8.89 Reject
Marking is deleted 7 4-2-7 9.15 9.74 9.05 9.59 9.38 9.77 9.27 9.40 9.55 9.50 Reject
Marking is deleted 8 4-2-8 8.94 9.20 8.90 8.39 8.86 9.67 9.19 8.72 8.90 9.12 Reject
Marking is deleted 9 4-2-9 9.33 9.04 8.76 9.09 9.06 8.42 9.09 9.04 9.28 8.96 Reject
Marking is deleted 10 4-2-10 9.31 9.03 8.86 8.80 9.00 8.79 8.26 8.97 9.09 8.78 Reject
Marking is deleted 1 4-3-1 9.37 9.25 9.39 9.43 9.36 9.40 9.20 9.11 9.68 9.35
Marking is deleted 2 4-3-2 9.39 9.48 8.87 8.85 9.15 9.37 9.11 8.90 9.20 9.15
Marking is deleted 3 4-3-3 8.94 9.00 9.54 9.80 9.32 9.50 9.32 8.80 9.54 9.29
Marking is deleted 4 4-3-4 9.67 9.96 9.16 9.00 9.45 9.36 9.16 9.30 8.90 9.18
Marking is deleted 5 4-3-5 9.51 10.00 9.26 8.77 9.39 9.00 9.30 9.50 9.00 9.20
Drift Code "X16"
Drift O.D. "157.46 mm
Drift Length "162 mm"
Marking is deleted 6 4-3-6 9.67 8.81 8.87 9.76 9.28 9.79 9.44 9.32 9.00 9.39
Marking is deleted 7 4-3-7 8.99 8.80 9.65 9.51 9.24 9.20 9.25 9.00 9.27 9.18
Marking is deleted 8 4-3-8 9.63 9.53 9.14 8.51 9.20 9.74 9.32 9.15 8.83 9.26
Marking is deleted 9 4-3-9 8.66 9.90 10.00 9.24 9.45 9.00 9.35 9.14 8.99 9.12
Marking is deleted 10 4-3-10 9.26 9.11 9.34 8.96 9.17 9.36 8.74 9.41 9.42 9.23
All the wall thickness measurements on the above-mentioned tables represent only the thickness of the ends of the tested samples
and don't represent other pipes other than the tested samples.
Y.s (Mpa) T.S (Mpa) El %
Item No. Specs according to Warehouse racks Availability of MTC Tracing No. HT No.
Obtained RMTC Obtained RMTC Obtained RMTC
1-1 0-84520 616 581-629 713 705-739 28.1 27-32
1 Plain end casing 7" -26 ppf - L80-R3 -TPCO Available 1-2 its seem that firing heat didn't effect on mechanical prop. Because the results
COMMENT obtained from tensile test for random sample extremely close to results for the
1-3 same HN and grade results variation in RMTC
Green Pipe Casing 7" -26 ppf - Target Grade L80- TPCO there is no dangerous on the pipes to be heated by fire as this pipes will be
4 Or Available heated again and the WT test show good results, the results of tensile test prove
Green Pipe Casing 7” -26ppf – Target Grade N80Q -Dalipal this pipes Is Green but the problem here is that we don’t have any conclusive
4-3 COMMENT evidence as Marking to differentiate between TPCO or DALIPAL pipes except
applying chemical analysis test for this sample as after good revision for the
two RMTC for them we found difference in some elements as shown in below
table
5 Casing 7" Without Marking N/A 5-1 after applying tensile test and WT test this pipes the results obtained improved
COMMENT this pipe is belongs to green pipe of 7" ,26 ppf but we will face the same
problem of item 4 , so we will apply chemical analysis test.
By Doing Chemical test for item No.4 & 5 as there are difference in some elements in RMTC as shown C Si Mn Cr Ni Mo Cu
DALIPAL 0.32 0.2 1.24 0.061 0.03 0 0.062
RMTC
TPCO 0.27 0.27 1.53 0.185 0.05 0.05 0.1
ITEM 4 Obtained 0.279 0.235 1.499 0.1557 0.0539 0 0.11
ITEM 5 Obtained 0.277 0.256 1.497 0.1716 0.0481 0 0.098
Comment 1- the results obtained for items 4 and 5 too close to the chemical composition of TPCO mill
2- by revising the chemical analysis results that obtained for the remaining items(1,2 and 3) ,they are in the same range of
RMTC, by taking into consideration the variation of our machine
All the results (Yield strength, Ultimate tensile strength, Elongation and chemical analysis) on the above-mentioned tables represent only the tested samples
and don't represent any pipe other than the tested samples.