CONTROL OF INSPECTION,
MEASURING AND TESTING EQUIPMENT
1. PURPOSE
The purpose of this procedure is to describe the method used to ensure that :
Inspection, measuring and testing equipment has been checked for accuracy (i.e. the
equipment has been calibrated), and;
The result of the checks, are maintained so that the current status of each piece of
equipment maybe readily determined.
2. SCOPE
This procedure shall apply to all inspection, measuring and testing equipment used by PMM
Project personnel (including staff and direct control labor).
This procedure does not apply to equipment used by subcontractors, suppliers or inspection
/ testing agencies employed by PMM.
3. TERMINOLOGY
Calibration: All the operations for the purpose of determining the value of the errors of a
measuring instrument.
4. REFERENCES
5. ACTIONS
5.1 General
5.1.1 Equipment used for acceptance, inspection, measuring and testing shall be calibrated
and controlled in accordance with this procedure.
5.1.2 Site measuring, inspection and testing equipment which has not been formally
calibrated, but is maintained in serviceable condition, may be used for routing in-
process inspection, measuring and testing.
5.1.3 Where a registered laboratory is used for inspection, measuring or test activities it
shall be accepted that the agency has complied with requirements of the quality
system element which this Quality Management Procedure addresses.
QUALITY MANAGEMENT PROCEDURES
DETERMINE INSPECTION,
MEASURING AND TESTING
REQUIREMENTS
(1)
NO
CHECK INITIATE CORRECTIVE / PREVENTIVE
SATISFACTORY? ACTION PROCEDURE (NOTE ON
CALIBRATION REGISTER (8)
YES
YES
EQUIPMENT
STILL TO BE
USED ON SITE?
NO
FILE RECORDS
(10)
Flowchar
t Activity Documentation Responsibility
Item No.
Flowchar
t Activity Documentation Responsibility
Item No.
5 ESTABLISH CALIBRATION REGISTER FOR
EACH ITEM OF EQUIPMENT
Flowchar
t Activity Documentation Responsibility
Item No.
(i) Determine the possible effects of
possible incorrect inspection,
measuring and testing results;
FILE RECORDS
10
Whose status has changed to on site but
not in use (i.e. in storage)
Quality Assurance
Establish and maintain files for storage of Project Filing Coordinator
records (see Note (e)) System
Notes:
(a) The method of check shall generally be selected from one of the following:
(i) Check against a Reference Measurement Standard, the accuracy of which can be
traced to a national standard e.g. standard measuring tape supplied with a
calibration certificate;
(ii) Accepted accuracy check tests e.g. two pegs test for a survey level; or,
The acceptable accuracy criteria shall be selected based on the nature of the
measurement and the allowable tolerances.
(b) The identification number shall be readily visible on each item of equipment. Where , the
identification number may be engraved on the equipment so that it is necessary clearly
visible and not easily removed.
(c) The list of Inspection, Measuring and Testing Equipment shall be used to document the
availability of each item of equipment on the site and its current usage status.
For equipment whose status is on site and in use, the check of equipment accuracy shall
be kept up to date in accordance with the Schedule of Equipment Calibration
Requirements.
Where the check of accuracy of an item of equipment is not kept up to date the status of
equipment shall be revised on the List of Inspection, Measuring and Testing Equipment.
The date from which the revised status is applicable shall be entered on the list.
(d) A Calibration Register shall be used to document the initial registration of each item of
equipment, the current calibration status and the requirements for checking which have
been transferred from the Schedule of Equipment Calibration Requirements.
(e) Sufficient provision shall be made by the custodian to store documents in the filing system.
Typically the provisions shall consist of clearly labeled and sub-divided lever arch files.
Documents shall be placed within each file in consistent and pre-determined manner (using
either registration numbers placed on the document, dates and/or file subdivisions) to allow
efficient retrieval.
6. ATTACHMENTS