Reinforcement Calculation

Proposed Mini Convention


Concrete Strength (fcu) = 20 N/mm2 Centre (MDTU) for Eastern
Min. r/f [As (mim)] = 0.13 % of c/s Province at Trincomalee

Design
Panel

Location Dimension Design Eff. depth R/F R/F provided R/F provided service M/bd2
moment required stress

lx ly M d As (req) As(pro) fs
mm mm kNm/m mm mm2/m mm2/m N/mm2
TWO WAY
Short Con. edge 2625 4725 5.93 82 174 T 10 @ 225 349 OK
Mid 4.44 82 131 T 10 @ 225 349 OK 115 0.661
Panel 1
Long Con. Edge 0.00 72 0 T 10 @ 200 393 OK
Mid 2.83 72 95 T 10 @ 200 393 OK
Short Con. edge 3675 4425 7.95 82 239 T 10 @ 225 349 OK
Mid 5.93 82 175 T 10 @ 225 349 OK 153 0.882
Panel 2
Long Con. Edge 5.68 72 193 T 10 @ 200 393 OK
Mid 4.29 72 144 T 10 @ 200 393 OK
Short Con. edge 2500 4425 5.08 82 149 T 10 @ 225 349 OK
Mid 3.80 82 112 T 10 @ 225 349 OK 98 0.565
Panel 3
Long Con. Edge 2.63 72 88 T 10 @ 200 393 OK
Mid 1.99 72 66 T 10 @ 200 393 OK
Short Con. edge 3800 4425 8.50 95 217 T 10 @ 275 286 OK
Mid 6.34 95 161 T 10 @ 275 286 OK 173 0.703
Panel 4
Long Con. Edge 6.07 85 172 T 10 @ 250 314 OK
Mid 4.59 85 130 T 10 @ 250 314 OK
Short Con. edge 2625 2850 2.44 82 72 T 10 @ 225 349 OK
Mid 1.83 82 54 T 10 @ 225 349 OK 47 0.272
Panel 5
Long Con. Edge 2.05 72 69 T 10 @ 200 393 OK
Mid 1.55 72 52 T 10 @ 200 393 OK
Short Con. edge 2625 5025 4.92 82 144 T 10 @ 225 349 OK
Mid 3.67 82 108 T 10 @ 225 349 OK 95 0.546
Panel 7
Long Con. Edge 2.71 72 91 T 10 @ 200 393 OK
Mid 2.05 72 69 T 10 @ 200 393 OK
Short Con. edge 3800 5025 8.37 95 213 T 10 @ 275 286 OK
Mid 6.34 95 161 T 10 @ 275 286 OK 173 0.703
Panel 9
Long Con. Edge 4.99 85 142 T 10 @ 250 314 OK
Mid 3.78 85 107 T 10 @ 250 314 OK
Deflection
Modifi. Span/Eff

check
factor depth

MF allow actual

2.00 46.0 32.0 OK

2.00 52.0 44.8 OK

2.00 52.0 30.5 OK

2.00 46.0 40.0 OK

2.00 46.0 32.0 OK

2.00 52.0 32.0 OK

2.00 46.0 40.0 OK


Shear Check
Design 100As (100As/ (400/ (fcu/ Design
shear 25) Location Con. Sh.
stress / bvd bvd) (1/3) d)(1/4) (1/3) Stress

v dir. vc
N/mm2 N/mm2

0.18 0.43 0.75 1.49 0.93 Short Edge-1 0.66 OK


0.12 0.43 0.75 1.49 0.93 Edge-2 0.66 OK
0.10 0.55 0.82 1.54 0.93 Long Edge-1 0.74 OK
0.10 0.55 0.82 1.54 0.93 Edge-2 0.74 OK
0.20 0.43 0.75 1.49 0.93 Short Edge-1 0.66 OK
0.13 0.43 0.75 1.49 0.93 Edge-2 0.66 OK
0.19 0.55 0.82 1.54 0.93 Long Edge-1 0.74 OK
0.12 0.55 0.82 1.54 0.93 Edge-2 0.74 OK
0.14 0.43 0.75 1.49 0.93 Short Edge-1 0.66 OK
0.09 0.43 0.75 1.49 0.93 Edge-2 0.66 OK
0.11 0.55 0.82 1.54 0.93 Long Edge-1 0.74 OK
0.07 0.55 0.82 1.54 0.93 Edge-2 0.74 OK
0.20 0.30 0.67 1.43 0.93 Short Edge-1 0.56 OK
0.13 0.30 0.67 1.43 0.93 Edge-2 0.56 OK
0.20 0.37 0.72 1.47 0.93 Long Edge-1 0.62 OK
0.13 0.37 0.72 1.47 0.93 Edge-2 0.62 OK
0.10 0.43 0.75 1.49 0.93 Short Edge-1 0.66 OK
0.10 0.43 0.75 1.49 0.93 Edge-2 0.66 OK
0.11 0.55 0.82 1.54 0.93 Long Edge-1 0.74 OK
0.07 0.55 0.82 1.54 0.93 Edge-2 0.74 OK
0.18 0.43 0.75 1.49 0.93 Short Edge-1 0.66 OK
0.18 0.43 0.75 1.49 0.93 Edge-2 0.66 OK
0.14 0.55 0.82 1.54 0.93 Long Edge-1 0.74 OK
0.09 0.55 0.82 1.54 0.93 Edge-2 0.74 OK
0.20 0.30 0.67 1.43 0.93 Short Edge-1 0.56 OK
0.13 0.30 0.67 1.43 0.93 Edge-2 0.56 OK
0.18 0.37 0.72 1.47 0.93 Long Edge-1 0.62 OK
0.18 0.37 0.72 1.47 0.93 Edge-2 0.62 OK
Table 1.3 Bending Mome Proposed Mini Convention Centre
(MDTU) for Eastern Province at
Note 1. n*- ultima Trincomalee
2. M*- bending moment due to line loads
Shear
Panel Type of Location Shear Shear Design
panel force force shear
coeffi. stress

dir. βv V v
kN N/mm2
Short Edge-1 0.60 14.7 0.18
One long Edge-2 0.39 9.6 0.12
Panel 1 edge Conti. Long Edge-1 0.29 7.1 0.10
Edge-2 0.29 7.1 0.10
Short Edge-1 0.47 16.1 0.20
Two Adju. Edge-2 0.31 10.6 0.13
Panel 2
edges Conti. Long Edge-1 0.40 13.7 0.19
Edge-2 0.26 8.9 0.12
Short Edge-1 0.57 13.3 0.14
Two Adju. Edge-2 0.38 8.9 0.09
Panel 3 edges Conti. Long Edge-1 0.40 9.3 0.11
Edge-2 0.26 6.1 0.07
Short Edge-1 0.47 16.7 0.20
Two Adju. Edge-2 0.31 11.0 0.13
Panel 4
edges Conti. Long Edge-1 0.40 14.2 0.20
Edge-2 0.26 9.2 0.13
Short Edge-1 0.39 8.2 0.10
One short Edge-2 0.39 8.2 0.10
Panel 5 edge
disconti. Long Edge-1 0.36 7.6 0.11
Edge-2 0.24 5.1 0.07
Short Edge-1 0.52 14.5 0.18
One short Edge-2 0.52 14.5 0.18
Panel 7 edge
disconti. Long Edge-1 0.36 10.1 0.14
Edge-2 0.24 6.7 0.09
Short Edge-1 0.47 16.7 0.20
One Long Edge-2 0.31 11.0 0.13
Panel 9 edge
disconti. Long Edge-1 0.36 12.8 0.18
Edge-2 0.36 12.8 0.18
Short Edge-1 0.44 15.6 0.19
One short Edge-2 0.44 15.6 0.19
Panel 10 edge
disconti. Long Edge-1 0.36 12.8 0.18
Edge-2 0.24 8.5 0.12
Short Edge-1 0.40 22.2 0.23
Two Adju. Edge-2 0.26 14.4 0.15
Panel 11
edges Conti. Long Edge-1 0.40 22.2 0.26
Edge-2 0.26 14.4 0.17
Short Edge-1 0.48 14.5 0.18
One long Edge-2 0.32 9.6 0.12
Panel 12 edge Conti. Long Edge-1 0.29 8.7 0.12
Edge-2 0.29 8.7 0.12
Short Edge-1 0.49 13.7 0.17
Two Adju. Edge-2 0.32 8.9 0.11
Panel 14 edges Conti.
Two Adju.
Panel 14 edges Conti.
Long Edge-1 0.40 11.2 0.16
Edge-2 0.26 7.3 0.10
Bending Moment and Shear Stress Calculation
Shear

Shear force Design


Location coeffi. Shear force shear
stress
Panel Type of panel
dir. V v
kN N/mm2
Short Edge-1 0.60 14.72 0.17
Panel 6 Interior Panels
Edge-2 0.60 14.72 0.17

Short Edge-1 0.46 12.85 0.15


Panel 8 One short edge
conti.
Edge-2 0.46 12.85 0.15

Short Edge-1 0.46 15.79 0.19


One short edge
Panel 13 conti.
Edge-2 0.46 15.79 0.19
Sujeethar Anaac
1s
Dead Loads Imposed Loads
Weight of R/F Concrete (kN/m3) 24.00 Hall & Hall way (kN
Weight of Finishes both top & Bottom (kN/m 2) 1.00 Common Area (kN/
Weight of Finishes both top & Bottom with floor tile (kN/m ) 2
1.50 Rooms (kN/m2)
Weight of Filling Mass Concrete (kN/m 3) 20.00 Toilets (kN/m2)
Light weight Aluminium Partition (kN/m 2) 1.00

Moments Due to Uniformly Distr

Dead Load

Total Characteristic

Imposed Load
Dead Load
Length/m

Width/m

Filling Mass
Panel Category

Aluminium
Wgt of R/C

Partition
&B
Finishes

Panel 1 Room 4.73 2.63 2.69 1.50 4.19 3.00

Panel 2 Room 4.43 3.68 2.69 1.50 4.19 3.00

Panel 3 Room 4.43 2.50 2.69 1.50 4.19 3.00

Panel 4 Room 4.43 3.80 2.69 1.50 4.19 3.00

Panel 5 Room 2.85 2.63 2.69 1.50 4.19 2.00

Panel 7 Hall 5.03 2.63 2.69 1.50 4.19 4.00

Panel 9 Room 5.03 3.80 2.69 1.50 4.19 3.00

Panel 10 Room 5.03 3.80 2.69 1.50 4.19 3.00

Panel 11 Hall 5.03 5.03 3.00 1.50 4.50 4.00

Panel 12 Room 3.53 3.23 2.69 1.50 4.19 3.00


Panel 14 Balcony 3.23 2.63 2.69 1.50 4.19 4.00

Moments Due to Uniform

Characteristic
Dead Load

Imposed Load
Dead Load
Length/m

Width/m

Panel Category

112.5mm Brick

Filling Mass
Wgt of R/C

T&B

Load
Finishes

Total
Panel 6 Hall Way 7.65 2.63 2.69 1.50 4.19 3.00

Panel 8 Balcony 7.28 2.63 2.69 1.50 4.19 4.00

Panel 13 Balcony 9.15 3.23 2.69 1.50 4.19 4.00


Sujeethar Anaachy Home, Batticaloa
1st Floor
Imposed Loads
Hall & Hall way (kN/m 2) 4.00 Slab Thick (m)
Common Area (kN/m2) 4.00 Slab Thick (m)
Rooms (kN/m ) 2
3.00 Slab Thick (m)
Toilets (kN/m2) 2.00 Slab Thick (m)
Filling Area thick (m)

to Uniformly Distributed Load Two-way spanning slab


(1.4 Gk + 1.6 Qk)
Ultimate Load per 1m Unit

Shorter span Longer span


Two way / One way

Coefficient (bsx) Coefficient (bsy)


(KN/m)

At Cont. Edge

At Cont. Edge
ly/lx

At Mid Span

At Mid Span
Type of Panel

(bsy1)

(bsy2)
(bsx1)

(bsx2)
Width

One long edge


9.35 1.80 Two way 0.092 0.069 0.000 0.044
Conti.
Two Adju. edges
9.35 1.20 Two way 0.063 0.047 0.045 0.034
Conti.
Two Adju. edges
9.35 1.77 Two way 0.087 0.065 0.045 0.034
Conti.
Two Adju. edges
9.35 1.16 Two way 0.063 0.047 0.045 0.034
Conti.
One short edge
8.05 1.08 Two way 0.044 0.033 0.037 0.028
disconti.
One short edge
10.65 1.91 Two way 0.067 0.050 0.037 0.028
disconti.
One Long edge
9.35 1.32 Two way 0.062 0.047 0.037 0.028
disconti.
One short edge
9.35 1.32 Two way 0.052 0.039 0.037 0.028
disconti.
Two Adju. edges
11.05 1.00 Two way 0.047 0.036 0.045 0.034
Conti.
One long edge
9.35 1.09 Two way 0.065 0.048 0.000 0.044
Conti.
Two Adju. edges
10.65 1.22 Two way 0.063 0.047 0.045 0.034
Conti.

nts Due to Uniformly Distributed Load One-way spanning slab


(1.4 Gk + 1.6 Qk)
Ultimate Load per 1m Unit

Two way / One way

Shorter span Coefficient (bsx)


(KN/m)

ly/lx Type of Panel


Near
At first Middle
At Outer middle
interior interior
support of end
Width

support span
0.040 span
0.086 0.063
0.075
9.35 2.91 One way Interior Panels 0.000 0.000 0.086 0.063
One short edge
10.65 2.77 One way 0.040 0.075 0.040 0.000
conti.
One short edge
10.65 2.83 One way 0.040 0.075 0.040 0.000
conti.
0.150
0.138
0.125
0.112
0.075

Maximum Design Bending Moments


Moments in Shorter Moments in Longer
Span Span

At Cont. At Mid At Cont. At Mid


Edge Span Edge Span
Msx1= Msx2= Msy1= Msy2=
bsx.n.lx2 bsx.n.lx 2
bsy.n.lx 2
bsy.n.lx2

5.93 4.45 0.00 2.84

7.96 5.94 5.69 4.30

5.09 3.80 2.63 1.99

8.51 6.35 6.08 4.60

2.45 1.84 2.06 1.56

4.92 3.67 2.72 2.06

8.38 6.35 5.00 3.79

7.03 5.27 5.00 3.79

13.12 10.05 12.56 9.49

6.33 4.67 0.00 4.28


4.63 3.45 3.31 2.50

Maximum Design Bending Moments


cient (bsx)

Moments in Shorter Span

Near At first Middle


Interior At Outer middle of interior interior
Interior
support support end span support span
support
0.063 bsx.F.lx bsx.F.lx
bsx.F.lx bsx.F.lx bsx.F.lx

0.063 0.00 0.00 5.55 4.06 4.06

0.000 2.94 5.51 2.94 0.00 0.00

0.000 4.44 8.31 4.44 0.00 0.00