Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

ABOUT CONTACT US PRIVACY POLICY DISCLAIMER     

BLOG.TEKNISI Select Language


The Electronic Technician's Powered by
Diary - Berbagi Ilmu dan
Belajar Translate

 HOME FAULT CODES  DIAGNOSTIC SOFTWARE CAT ELECTRONIC TECHNICIAN ALLISON TRANSMISSION

SEARCH... 

Home » Electronic Engines


» Identify Types of Basic Circuit Faults and Wiring Harness Categories
Test

Fault Codes CUMMINS ISB ISC
ISL ISBe ISDe and QSB3.3
CM2150
(168)
Identify Types of Basic Circuit Faults and 
Fault Codes CUMMINS GTA38
K38 K50 QSK38 QSK50/60 CM850
Wiring Harness Test (97)

Fault Codes CUMMINS

Blog.Teknisi

Tuesday, March 10, 2020

Electronic Engines Signature ISX QSX15 CM570
(94)

Diesel Engine Software
(70)
Ads by

Fault Codes CUMMINS ISB
Stop seeing this ad Why this ad?  ISBe QSB4.5 QSB5.9 QSB6.7 ISC
Correlate End-to-End M365 Data QSC8.3 ISL ISLe QSL9 CM850
(CM2850)
(52)
Leverage service insights to achieve proper response and


Caterpillar Electronic Technician
remediation.
(48)

CUMMINS Diesel Engines
(41)

ALLISON Transmission
(38)

DETROIT Diesel Engines
(27)
Martello Technologies Download

Car Diagnostics
(24)

PLC Programming
(16)

Basic Hydraulics
(12)
Basic Circuit Faults and Wiring Harness 
Starting and Charging System
Test (10)

Fuel System Caterpillar Engine
(9)

Setting Display
(8)

Electronic Engines
(6)

Radio Programming
(6)

Automatic Lubrication System
(5)

Competency Training
(5)

Generator Set
(5)

Manual Book & Datasheet
(4)

Air Compressor System
(3)

Fire Suppression System
(2)

Micro Motion
(2)

WOODWARD Load Sharing &
Speed Control
(2)

Contact Us
(1)

Ads by
Stop seeing this ad

 ?Why this ad

Series Circuit


‫نیاز به کارمندان‬
Read More:

Senders/ Sensors on Electronic Engines

‫اطالعاتی است‬
Sensor Diagnostics on Electronic Engines

Circuit Malfunctions

There are several ways that a circuit can malfunction.  Most electrical ‫به کاندیدان مناسب پیشنها
د‬
malfunctions are caused by opens, shorts, grounds, high resistance, or

‫شغلی با مزایای عالی و حقوق بی‬
intermittent.


‫ تماس‬,‫نهایت باال را میدهیم‬
#Opens

‫بگرید‬
An open in any part of a circuit is, in effect, an extremely high resistance
that results in no current flow in the circuit.  An open can be caused by a
failed component such as a switch or fuse, or a broken wire or connector. 
The physical location of the open determines how the circuit will react.  In a
series circuit, any open connection will result in no current flow in the
circuit.  The illustration above shows an open in a series circuit.  The switch
acts as an open and therefore no current will flow through the two loads
when the switch is open.

Troubleshooting an open circuit is easily accomplished using a multimeter


and measuring source voltage.  If source voltage is available at the
connection ahead of the switch and not available on the load side of the
switch, the switch contacts are open.  If voltage is available on the load
side, it would be necessary to continue checking the circuit until the open is
identified.

Parallel Circuit

In a parallel circuit, identifying an open depends on where the open occurs. 


If the open occurs in the main line, none of the loads or components will
work. In effect, all parallel branches will not operate. Additionally, an open in
the return ground path would have the same effect as an open in the main
line. An open in the return ground path is referred to as an "open ground".

If the open occurs in any of the branches past the main line, only the load
on that specific branch is affected.  All other branch loads will operate
normally. The illustration above shows an example of an open in the main
line and in a parallel branch.

When troubleshooting or diagnosing an open in a circuit, the result is


normally a component that fails to operate or function. Since most  power
circuits are protected with some type of a fuse or circuit protection device, it
is recommended that the fuse or device be checked visually.  If a visual
check does not reveal an open condition, remove the device and perform a
resistance or continuity check to ensure that the device is functional. The
next most probable place to check for an open is at the component
itself. Using a multimeter and an electrical schematic, determine if system
or source voltage is available.  If voltage is not present at the component,
the next step is to determine what other electrical devices, such as
switches or connectors, are in the circuit path.  Eliminate those devices,
starting at the easiest location and working back toward the voltage source.

#Short Circuits

A short in a circuit is a direct electrical connection between two points,


usually a very low resistance or opposition to current flow.  It most often
describes an unwanted or incorrect electrical connection and may draw
higher than expected current.  In describing malfunctions caused by
electrical shorts, the type of short is usually identified as a "short to ground"
or a "short to power".

A short to ground occurs when current flow is grounded before it was


intended to be. This usually happens when wire insulation breaks and the
conductor actually comes in contact with the machine ground. The effect of
a short to ground depends on the design of the circuit and on its location in
relationship to other circuit components such as protection devices,
switches, loads, etc.

Ads by
Stop seeing this ad Why this ad? 
Correlate End-to-End M365 Data
Leverage service insights to achieve proper response and

remediation.

Martello Technologies Download

The above illustration shows the short occurring after the protection device
and switch, but before the circuit load (lamp).  In this example, a low
resistance path to ground occurs whenever the switch is turned on and
source voltage is available. The result of this unwanted path will result in an
opened fuse (or tripped breaker) when the switch is turned on.

The above illustration shows the short to ground occurring before the
switch. This condition is often referred to as a "dead short". In this situation,
the fuse will open any time circuit voltage is applied.

A short to power or supply occurs when one circuit is shorted to another


circuit. The symptoms of a short to power again depends on the location of
the short. The result of this type of condition generally causes one or both
circuits to operate improperly, such as a component being energized when
it is not supposed to be. The root cause of this condition is typically worn or
frayed electrical wiring. Also, this condition rarely causes protection devices
to open or damage to other components.

The above illustration shows the short to power occurring before the
controlling devices (switches).  This condition allows either switch to control
the two loads.

The above illustration shows the short to power occurring after the load in
one branch and before the load in the other.  In this case, if the switch
controlling Circuit #2 is turned on, the load does illuminate, but if the switch
controlling Circuit #1 is turned on, a direct short to ground occurs resulting
in the fuse opening.

Read More:

Electronic Control Module (ECM)

PULL-UP Voltage and How the ECM Uses it to Determine Diagnostic


Conditions

Wiring Harness (Open Circuit) - Test

TEST FOR AN OPEN CIRCUIT:

1. Identify the connectors and the wire numbers of the suspect circuits. Use
the Electrical System Schematic of the machine to identify the circuits.

2. Turn the key start switch and the disconnect switch to the OFF position.

Ads by
Stop seeing this ad Why this ad? 
Working in the New Normal
Optimizing Microsoft Teams Performance for the Modern

Workplace

Martello Technologies Download

3. Disconnect the component and the ECM from the wiring harness.
Ads by
Stop seeing this ad Why this ad? 
PS615 - Available
Starting at: $Submit for Price
Tripp Lite ® Authorized Distributor

onlinecomponents.com OPEN

4. At one of the disconnected harness connections, place a jumper wire


from the contact of the suspect wire to frame ground.

5. At the other connector of the machine harness, use the multimeter


probes to measure the resistance from the contact of the suspect wire to
frame ground.

Expected Result:

OK - The resistance is less than 5 ohms (The harness circuit is correct).

Not OK - The resistance is greater than 5000 ohms. There is an open in the
machine harness.

Wiring Harness (Short Circuit) - Test

TEST FOR A SHORT CIRCUIT:

1. Identify the connectors and the wire numbers of the suspect circuits. Use
the Electrical System Schematic of the machine to identify the circuits.

2. Turn the key start switch and the disconnect switch to the OFF position.

3. Disconnect the component and the ECM from the wiring harness.

4. At the machine harness connector for the ECM, place one of the
multimeter probes on the contact of the suspect wire.

5. Use the other multimeter probe to check the resistance across all other
contacts in the connector (s) of the ECM and frame ground.

Expected Result:

OK - The resistance is greater than 5000 ohms for all the measurements
(The harness circuits are correct).

Not OK - The resistance is less than 5 ohms. There is a short in the


machine harness. The short is between the suspected wire and the wire
with the lowest resistance measurement.

Blog.Teknisi
Ads by
Stop seeing this ad Why this ad? 

Current Transformers 50/60Hz


The industry leader in custom magnetic components Since 1975

    

Subscribe to receive free email updates:

Your email address...

Subscribe

Related Posts :

Senders/ Sensors on Electronic Engines


Senders/ Sensors (Caterpillar)
Senders/ Sensors (Variable Input
Devices)
Read More:
Identify Types of Basic Circuit Faults and
Wiring H… Read More...

Identify Types of Basic Circuit Faults and Wiring Harness


Test
Basic Circuit Faults and Wiring Harness Test
Series Circuit
Read
More:
Senders/ Sensors on Electronic Engines
Sensor
Diagnostics on Elec… Read More...

Detroit Diesel Electronic Control/ DDEC System (Detroit


Engines)
Electronic Control Module (ECM)Figure 1.1 - ECM DDEC IV
(Series 60)#THE BASICSThe ECM can be considered the most
important component of the … Read More...

PULL-UP Voltage and How the ECM Uses it to Determine


Diagnostic Conditions
PULL-UP Voltage
Read More:
Sensor Diagnostics on Electronic
Engines
Identify Types of Basic Circuit Faults and Wiring
Harness Test
Pu… Read More...
Sensor Diagnostics on Electronic Engines
Sensor Diagnostics on Electronic Engines (Caterpillar)
Figure
1.1 - Diagnostic Code: 1836-3
Read More:
Identify Types of
Basic Circui… Read More...

0 Response to "Identify Types of Basic Circuit Faults and


Wiring Harness Test"

Enter your comment...

Comment as: