Professional Documents
Culture Documents
Flat, 5 MM 2 Form C, 2A, Surface Mount Terminal Relays
Flat, 5 MM 2 Form C, 2A, Surface Mount Terminal Relays
TQ RELAYS
(Unit:mm)
ORDERING INFORMATION (PART NO. : Ordering part number for Japanese market)
ATQ 2
Contact arrangement
2:2 Form C (2 Form D)
*1: 48 V coil type: Single side stable only
*2: In case of 5 V transistor drive circuit, it is recommended to use 4.5 V type relay.
*3: The“W”and“Y”at the end of the part number is only available for SA and SS.
*4: Each reel is packed with humidity indicators and silica gel in the moisuture proof pack.
ORDERING INFORMATION (TYPE NO. : Ordering part number for non Japanese market)
TQ
Packing style*3
Nil:Tube packing
Terminal shape MBB function X :Tape and reel(picked from 1/2/3/4/5-pin side)
Nil:Standard PC board terminal Nil : Standard(B.B.M.)type Z :Tape and reel packing(picked from the 6/7/8/9/10-pin side)
H :Self-clinching terminal 2M: 2M.B.B. type W :Tape and reel packing (picked from the 1/2/3/4/5-pin side)
SA:SA type With humidity indicator and silica gel in moisture proof bag*4
SL:SL type Y :ape and reel packing (picked from the 6/7/8/9/10-pin side)
Operating function
SS:SS type With humidity indicator and silica gel in moisture proof bag*4
Nil:Single side stable
Contact arrangement L :1 coil latching
L2:2 coil latching Rated coil voltage(DC)*1,2
2:2 Form C (2 Form D) 1.5(SMD only), 3, 4.5, 5, 6, 9, 12, 24, 48V
*1: 48 V coil type: Single side stable only
*2: In case of 5 V transistor drive circuit, it is recommended to use 4.5 V type relay.
*3: The“W”and“Y”at the end of the part number is only available for SA and SS.
*4: Each reel is packed with humidity indicators and silica gel in the moisuture proof pack.
TYPES
" Type No. " is ordering part number for non Japanese market. " Part No. " is ordering part number for Japanese market.
Standard contact
PC board terminal (standard): Tube packing
Single side stable 1 coil latching 2 coil latching Standard packing
Contact Rated coil
arrangement voltage Carton Outer
Type No. Part No. Type No. Part No. Type No. Part No.
(1 Tube packing) carton
3 V DC TQ2-3V ATQ201 TQ2-L-3V ATQ211 TQ2-L2-3V ATQ221
4.5 V DC TQ2-4.5V ATQ206 TQ2-L-4.5V ATQ216 TQ2-L2-4.5V ATQ226
5 V DC TQ2-5V ATQ209 TQ2-L-5V ATQ219 TQ2-L2-5V ATQ229
6 V DC TQ2-6V ATQ202 TQ2-L-6V ATQ212 TQ2-L2-6V ATQ222
2 Form C 50 pcs. 1,000 pcs.
9 V DC TQ2-9V ATQ207 TQ2-L-9V ATQ217 TQ2-L2-9V ATQ227
12 V DC TQ2-12V ATQ203 TQ2-L-12V ATQ213 TQ2-L2-12V ATQ223
24 V DC TQ2-24V ATQ204 TQ2-L-24V ATQ214 TQ2-L2-24V ATQ224
48 V DC TQ2-48V ATQ205 – – – –
MBB contact
Standard PC board terminal and self-clinching terminal: Tube packing
Standard Self-clinching terminal* Standard packing
Contact Rated coil
Single side stable Single side stable Inner carton
arrangement voltage Outer carton
Type No. Part No. Type No. Part No. (1-tube)
3 V DC TQ2-2M-3V ATQ20122 TQ2H-2M-3V ATQ23122
4.5 V DC TQ2-2M-4.5V ATQ20622 TQ2H-2M-4.5V ATQ23622
5 V DC TQ2-2M-5V ATQ20922 TQ2H-2M-5V ATQ23922
2 Form D 6 V DC TQ2-2M-6V ATQ20222 TQ2H-2M-6V ATQ23222 50 pcs. 1,000 pcs.
9 V DC TQ2-2M-9V ATQ20722 TQ2H-2M-9V ATQ23722
12 V DC TQ2-2M-12V ATQ20322 TQ2H-2M-12V ATQ23322
24 V DC TQ2-2M-24V ATQ20422 TQ2H-2M-24V ATQ23422
* Latching types are available by request. Please inquire our sales representative for details.
Coil data
• Operating characteristics such as “Operate voltage” and “Release voltage” are influenced by mounting conditions or ambient
temperature, etc.
Therefore, please use the relay within ±5% of rated coil voltage.
• “Initial” means the condition of products at the time of delivery.
Standard contact: Single side stable
Rated operating Max. allowable
Rated coil Operate voltage* Release voltage* Coil resistance
current Rated operating power voltage
voltage (at 20°C) (at 20°C) (±10%, at 20°C)
(±10%, at 20°C) (at 20°C)
3 V DC 46.7 mA 64.3 Ω
4.5 V DC 31.1 mA 145 Ω
5 V DC 28.1 mA 178 Ω
140 mW 150% V of
6 V DC Max. 75% V of Min. 10% V of 23.3 mA 257 Ω
rated coil voltage
9 V DC rated coil voltage rated coil voltage 15.5 mA 579 Ω
(Initial) (Initial)
12V DC 11.7 mA 1,028 Ω
24 V DC 8.3 mA 2,880 Ω 200 mW
120% V of
48 V DC 6.3 mA 7,680 Ω 300 mW
rated coil voltage
*square, pulse drive (JIS C 5442)
Electrical life
Conditions: resistance load, switching frequency 20 times / minute.
Type Switching capacity Number of operations
1 A 30 V DC Min. 200 x 103
2 Form C Standard contact
0.5 A 125 V DC Min. 100 x 103
2 Form D M.B.B. contact 1 A 30 V DC Min. 100 x 103
Coil data
• Operating characteristics such as “Operate voltage” and “Release voltage” are influenced by mounting conditions or ambient
temperature, etc.
Therefore, please use the relay within ±5% of rated coil voltage.
• “Initial” means the condition of products at the time of delivery.
Single side stable
Rated operating Max. allowable
Rated coil Operate voltage* Release voltage* Coil resistance
current Rated operating power voltage
voltage (at 20°C) (at 20°C) (±10%, at 20°C)
(±10%, at 20°C) (at 20°C)
1.5 V DC 93.8 mA 16 Ω
3 V DC 46.7 mA 64.3 Ω
4.5 V DC 31 mA 145 Ω
5 V DC 28.1 mA 178 Ω 140 mW 150% V of
Max. 75% V of Min. 10% V of rated coil voltage
6 V DC 23.3 mA 257 Ω
rated coil voltage rated coil voltage
9 V DC (Initial) (Initial) 15.5 mA 579 Ω
12 V DC 11.7 mA 1,028 Ω
24 V DC 8.3 mA 2,880 Ω 200 mW
120% V of
48 V DC 6.3 mA 7,680 Ω 300 mW
rated coil voltage
*square, pulse drive (JIS C 5442)
1 coil latching
Rated operating Max. allowable
Rated coil Set voltage* Reset voltage* Coil resistance
current Rated operating power voltage
voltage (at 20°C) (at 20°C) (±10%, at 20°C)
(±10%, at 20°C) (at 20°C)
1.5 V DC 46.9 mA 32 Ω
3 V DC 23.3 mA 128.6 Ω
4.5 V DC 15.6 mA 289.3 Ω
5 V DC Max. 75% V of Max. 75% V of 14 mA 357 Ω 70 mW 150% V of
rated coil voltage rated coil voltage
6 V DC 11.7 mA 514 Ω rated coil voltage
(Initial) (Initial)
9 V DC 7.8 mA 1,157 Ω
12 V DC 5.8 mA 2,057 Ω
24 V DC 4.2 mA 5,760 Ω 100 mW
*square, pulse drive (JIS C 5442)
Note: Please inquire with one of our sales representatives if you require a relay with an unlisted voltage.
2 coil latching
Rated operating
Coil resistance Max. allowable
Rated coil Set voltage* Reset voltage* current Rated operating power
(±10%, at 20°C) voltage
voltage (at 20°C) (at 20°C) (±10%, at 20°C)
(at 20°C)
Set coil Reset coil Set coil Reset coil Set coil Reset coil
1.5 V DC 93.8 mA 93.8 mA 16 Ω 16 Ω
3 V DC 46.7 mA 46.7 mA 64.3 Ω 64.3 Ω
4.5 V DC 31 mA 31 mA 145 Ω 145 Ω
5 V DC Max. 75% V of Max. 75% V of 28.1 mA 28.1 mA 178 Ω 178 Ω 140 mW 140 mW 150% V of
rated coil voltage rated coil voltage
6 V DC 23.3 mA 23.3 mA 257 Ω 257 Ω rated coil voltage
(Initial) (Initial)
9 V DC 15.5 mA 15.5 mA 579 Ω 579 Ω
12 V DC 11.7 mA 11.7 mA 1,028 Ω 1,028 Ω
24 V DC 8.3 mA 8.3 mA 2,880 Ω 2,880 Ω 200 mW 200 mW
*square, pulse drive (JIS C 5442)
Electrical life
Conditions: resistance load, switching frequency 20 times / minute.
Type Switching capacity Number of operations
1 A 30 V DC Min. 200 x 103
2 Form C 2 A 30 V DC Min. 100 x 103
0.5 A 125 V AC Min. 100 x 103
1
AC load(cosφ=1)
0.5
30V DC resistive load
0.4
10
0.3 DC load(cosφ=1) 125V AC resistive load
0.2
0 0
0 30 100 200 0 0.5 1
Contact voltage, V Switching capacity, A
30 Release
ratio, %
60
voltage Ave. 80
Operate voltage
Temperature rise, °
C
20
50 1A 70 Max.
24V DC Ave.
10 60 Min.
40 1A
0A -40 -20 0
50
20 40 60 80
30 Operate Ambient 40
voltage -10 temperature, °
C Release voltage
20 30 Max.
-20
3~12V DC 20
10 -30
10 Min.
0 -40 0
0 100 110 120 130 140 150 0 10 100 1,000 10,000
Coil applied voltage, %V No. of operations, ×104
90 90
Contact resistance, mΩ
80 Operate voltage 80
Max.
70 70
Min.
60 60
50 50 Max.
40 Release voltage 40
Max.
30 30 Min.
20 Min. 20
10 10
0 0
0 5 10 15 20 0 5 10 15 20
No. of operations, ×104 No. of operations, ×104
90 90
Contact resistance, mΩ
80 80
Operate voltage Max.
70 70
60 Min. 60
50 50
40 Release voltage Max. 40 Max.
30 30 Min.
20 Min. 20
10 10
0 0
0 5 10 0 5 10
No. of operations, ×104 No. of operations, ×104
90 90
Contact resistance, mΩ
80 Operate voltage 80
Max.
70 70
Min.
60 60
Max.
50 50
40 40
30 30
Release voltage Min.
20 Max. 20
10 Min. 10
0 0
0 500 1,000 1,500 2,000 0 500 1,000 1,500 2,000
No. of operations, ×104 No. of operations, ×104
7. Functional shock (Single side stable) 8-1. Influence of proximity mounting 8-2. Influence of proximity mounting
Tested sample:TQ2-12V, 6 pcs.
20 20
Rate of change, %
Rate of change, %
0 ℓ ℓ 0 ℓ
X Z Operate voltage Operate voltage
ON ON
-10 -10
-20 -20 ON
20 20
Rate of change, %
Rate of change, %
9-1. High frequency characteristics 9-2. High frequency characteristics 10. Contact reliability
(Isolation) (Insertion loss) (1 mA 5 V DC resistive load)
Tested sample:TQ2-12V
Condition:Detection level 10
99.9
99
95
70
Insertion loass, dB
50
Isolation, dB
100 30
F t), %
1
10
(
0.8 5
50 0.6 2
1 m=2.15
0.4 μ=2.7×107
0.5 95% reliability limit =
0.2 7.6×106
0.2
(Weibull probability paper)
0 0 0.1
0 10 100 1,000 0 10 100 1,000 1 10 100
Frequency, MHz Frequency, MHz No. of operations, ×106
60 60
Terminal No.2-3-4 ON Terminal No.2-3-4 ON
Ave. :105.6μs Ave. : 71.6μs
50 3σn-1:163.8μs 50 3σn-1:127.1μs
Min.: 23μs Min.: 17μs
Max.: 243μs 41 Max.: 187μs
40 40
Terminal No.7-8-9 ON 35 Terminal No.7-8-9 ON
Ave. :115.6μs 31 Ave. : 80.7μs
30
30 3σn-1:167.3μs 30 27 3σn-1:156.7μs
26 Min.: 35μs Min.: 29μs
21 Max.: 254μs Max.: 298μs
20 19 19 20
17
15
11 12
10 10 7
6 10
2 1 2
4 4
0 0
10 50 100 150 200 250 300μs min. 10 50 100 150 200 250 300μs min.
~
50 100 150 200 250 300 350μs max. 50 100 150 200 250 300 350μs max.
2 100
DC resistive load
1 50
30
0.5
0.4 AC resistive load 20
0.3
0.2 10
125V AC 30V DC
resistive load resistive load
0 0
0 20 30 50 100 200 300 0 1 2
Contact voltage, V Switching capacity, A
3. Coil temperature characteristics 4. Ambient temperature characteristics 5. Mechanical life (mounting by IRS method)
Tested sample:TQ2SA-12V, 6 pcs. Tested sample:TQ2SA-12V, 5 pcs. Tested sample:TQ2SA-12V, 10 pcs.
Point measured:Inside the coil
Ambient temperature:25° C
70 50 100
2A
30 80
0A
Temperature rise, °
C
0 -50 0
0 100 110 120 130 140 150 IRS1 10 100 1,000 10,000
Coil applied voltage, %V No. of operations, ×104
90 90
80 80
Contact resistance, mΩ
70 Operate voltage 70
Max.
60 Min. 60
50 50 Max.
40 40
Release voltage
30 30 Min.
Max.
20 20
10 Min. 10
0 0
IRS 1 2 3 4 5 6 7 8 9 10 IRS 1 2 3 4 5 6 7 8 9 10
No. of operations, ×104 No. of operations, ×104
Contact resistance, mΩ
80 80
70 Operate voltage 70
Max.
60 Min. 60
50 50
Max.
40 Release voltage 40
30 Max. 30 Min.
20 Min. 20
10 10
0 0
IRS 1 2 3 4 5 6 7 8 9 10 IRS 1 2 3 4 5 6 7 8 9 10
No. of operations, ×104 No. of operations, ×104
7. Operate and release time (without diode) 8. Functional shock (Single side stable) 9-1. Influence of proximity mounting
Tested sample:TQ2SA-12V, 6 pcs. Tested sample:TQ2SA-12V, 6 pcs Tested sample:TQ2SA-12V, 5 pcs.
5 20
Rate of change, %
Operate time [m/s2] Deenergized
Release time 1,000 Y 10 ON ON
condition
Operate and release time, ms
Energized
4
condition 0 ℓ ℓ
X Z Operate voltage
ON
Max. -10
3 Min.
-20
20
Rate of change, %
2 10 OFF OFF
Z’ X’
ZX 0 ℓ ℓ
Max.
1 Min. Z’
X’ Release voltage
Y
OFF
Y’ -10
Y’
0 -20
0 70 80 90 100 110 120 0 1 2 3 4 5 6
Coil applied voltage, %V Inter-relay distance,ℓ mm
9-2. Influence of proximity mounting 10-1. High frequency characteristics 10-2. High frequency characteristics
(Isolation) (Insertion loss)
Tested sample:ATQ209SA, 1 pcs. Tested sample:ATQ209SA, 1 pcs.
Tested sample:TQ2SA-12V, 6 pcs. (Isolation) (Insertion loss)
20
Rate of change, %
10 ON
ℓ
Insertion loass, dB
0 ℓ
Operate voltage
Isolation, dB
ON 100
-10
ON 1
-20
20
Rate of change, %
0.8
10 OFF
ℓ 50 0.6
0 ℓ 0.4
Release voltage OFF
0.2
-10
OFF
-20 0 0
0 1 2 3 4 5 6 0 10 100 1,000 0 10 100 1,000
Inter-relay distance, ℓmm Frequency, MHz Frequency, MHz
DIMENSIONS CAD The CAD data of the products with a “CAD” mark can be downloaded from our Website. Unit: mm
2.54
1 2 3 4 5
+
7.62
-
14 9 10-1.0 dia. 10 9 8 7 6
Tolerance:±0.1 Direction indication
0.25 (4.75)
3.5 5+0.4
ー0.2
+
PC board terminal (self-clinching terminal) 10 9 8 7 6
Direction indication
2 coil latching
(Reset)
14 9
1 2 3 4 5
+ -
0.25 (4.75)
3.5 5+0.4
ー0.2
+ -
10 9 8 7 6
Direction indication
2.54 0.5 0.25
7.62
General tolerance:±0.3
9
1 2.54
2.94
+
14 1 2 3 4 5
Direction indication
SA
9.56
0.25
4.9
5.6
0.2
Tolerance : ±0.1
2.54 0.5 7.62
1 coil latching
11.5±0.5
(Reset)
General tolerance : ±0.3
10 9 8 7 6
+
-
1 2 3 4 5
9
Direction indication
1 2.54
2.94
14
SL
9.56
2 coil latching
Max.7.5
4.9
(Reset)
0.25
Tolerance : ±0.1
2.54 0.5 7.62 10 9 8 7 6
11.5±0.5 + -
Direction indication
9
1 2.54
1.84
14
8.46
SS
Max.7.5
4.9
0.25
Tolerance : ±0.1
7.62
2.54 0.5 9.3±0.5
Tube packing
1. The relay is packing in a tube with the relay orientation mark
Orientation(indicates PIN No.1)stripe
on the left side,as shown in the figure below.
Be sure to maintain relays in the correct orientation when
mounting on PC boards.
2. Conditions for operation, transport and storage : –40 to 60°C.
Stopper(gray) Stopper(green)
1.75
0
(Z type)
11.5
24±0.3
2±0.5
14.6
330±2 dia.
80±1 dia.
TQ-SMD
16 12.3 6.3±0.2
relays
Tape coming out direction
Tolerance : ±0.1
13±0.2 dia.
SL Type 24.4+ 20 2±0.2
16 12.3 7.8±0.2
TQ-SMD
relays
Tape coming out direction
Tolerance :±0.1
SS Type
Relay polarity bar 1.5+ 0.1
0 dia. 2 4 2 dia. 0.4
1.75
(Z type)
11.5
24±0.3
14.6
16 10.1 7.8±0.2
TQ-SMD
relays
Tape coming out direction
Tolerance :±0.1
For cautions for use, please read “Relay Soldering and Cleaning Guidelines” and “SMT Soldering Guidelines”.
PC board terminal
In case of hand soldering, the following conditions should be observed.
The effect on the relay depends on the PC board used. Please verify the actual PC board to be used.
Automatic soldering (Flow) Hand soldering
Recommended Measurement Recommended Measurement
Temperature Time Temperature Time
conditions location conditions location
Within 120 Solder surface Within 3
Preheating Max. 120°C Soldering Max. 350°C Tip temperature
seconds terminal seconds
Within 6 Solder
Soldering 260°C ± 5°C
seconds temperature
Surface-mount terminal
In case of automatic soldering (reflow), the following conditions should be observed.
IRS (infrared reflow soldering method) heating conditions Mounting cautions
Recommend conditions Cautions to observe when mounting temperature increases
Number of reflow 1 time in the relay are greatly dependent on the way different parts
Measuring position Surface of PC board where relay is mounted. are located a PC board and the heating method of the reflow
device. Therefore, please conduct testing on the actual
t4
T3 t 1=60s to 120s
device beforehand after making sure the parts soldered on
T2
t 2=within 20s the relay terminals and the top of the relay case are within the
t 3=within 30s
T1 t 4=within 10s(245 to 250°
C) temperature conditions.
T1=150 to 180° C
t1 t2 t3 T2=230° C and higher
T3=250° C max
SAFETY STANDARDS Each standard may be updated at any time, so please check our Website for the latest information.
or cautions for use, please read “GUIDELINES FOR SIGNAL RELAYS USAGE” and “GUIDELINES FOR RELAY
F
USAGE”.
500Ω
5V DC
For cautions for use, please read "GUIDELINES FOR RELAY USAGE".
https://industrial.panasonic.com/ac/e/control/relay/cautions_use/index.jsp
Long term current carrying Maximum allowable voltage and temperature rise
A circuit that will be carrying a current continuously for Proper usage requires that the rated coil voltage be impressed
long periods without relay switching operation. (circuits for on the coil.
emergency lamps, alarm devices and error inspection that, for Note, however, that if a voltage greater than or equal to the
example, revert only during malfunction and output warnings maximum continuous voltage is impressed on the coil, the coil
with form B contacts) may burn or its layers short due to the temperature rise.
Continuous,long-term current to the coil will facilitate Furthermore, do not exceed the usable ambient temperature
deterioration of coil insulation and characteristics due to range listed in the catalog.
heating of the coil itself. For circuits such as these, please use Temperature rise due to pulse voltage
a magnetic-hold type latching relay. If you need to use a single When a pulse voltage with ON time of less than 2 minutes is
stable relay, use a sealed type relay that is not easily affected used, the coil temperature rise bares no relationship to the ON
by ambient conditions and make a failsafe circuit design that time.
considers the possibility of contact failure or disconnection. This varies with the ratio of ON time to OFF time, and
compared with continuous current passage, it is rather small.
DC Coil operating power The various relays are essentially the same in this respect.
Steady state DC current should be applied to the coil.
The wave form should be rectangular. If it includes ripple, the Current passage time %
ripple factor should be less than 5%. However, please check For continuous passage Temperature rise value is 100%
with the actual circuit since the electrical characteristics may ON : OFF = 3 : 1 About 80%
vary. ON : OFF = 1 : 1 About 50%
The rated coil voltage should be applied to the coil and the ON : OFF = 1 : 3 About 35%
set/reset pulse time of latching type relay differs for each
relays, please refer to the relay's individual specifications. ON : OFF = 1 : 1
Voltage
Coil connection
When connecting coils of polarized relays, please check coil
polarity(+,-) at the internal connection diagram (Schematic).
Time
If any wrong connection is made, it may cause unexpected
malfunction, like abnormal heat, fire and so on, and circuit do Operate voltage change due to coil temperature rise (hot start)
not work. In DC relays, after continuous passage of current in the coil, if
Avoid impressing voltages to the set coil and reset coil at the the current is turned OFF, then immediately turned ON again,
same time. due to the temperature rise in the coil, the operate voltage will
become somewhat higher. Also, it will be the same as using it
in a higher temperature atmosphere.
The resistance/temperature relationship for copper wire is
about 0.4% for 1°C, and with this ratio the coil resistance
increases.
That is, in order to operate of the relay, it is necessary that the
voltage be higher than the operate voltage and the operate
voltage rises in accordance with the increase in the resistance
value.
However, for some polarized relays, this rate of change is
considerably smaller.
NOTES
OTHERS
Cleaning
1) Although the environmentally sealed type relay (plastic sealed 3) Cleaning with the boiling method is recommended (The
type,etc.) can be cleaned, avoid immersing the relay into cold temperature of cleaning liquid should be 40°C or lower). Avoid
liquid (such as cleaning solvent) immediately after soldering. ultrasonic cleaning on relays.
Doing so may deteriorate the sealing performance. Use of ultrasonic cleaning may cause breaks in the coil or
2) Surface-mount terminal type relay is sealed type and it can be slight sticking of the contacts due to the ultrasonic energy.
cleaned by immersion.
Use pure water or alcohol-based cleaning solvent.