Professional Documents
Culture Documents
ExtremeXOS - 31.2.1-Patch1-5 - RelNotes (1) - Sofwaree
ExtremeXOS - 31.2.1-Patch1-5 - RelNotes (1) - Sofwaree
9036888-01 Rev AB
May 2021
Copyright © 2021 All rights reserved.
Legal Notice
Extreme Networks, Inc. reserves the right to make changes in specifications and other information
contained in this document and its website without prior notice. The reader should in all cases
consult representatives of Extreme Networks to determine whether any such changes have been
made.
The hardware, firmware, software or any specifications described or referred to in this document
are subject to change without notice.
Trademarks
Extreme Networks and the Extreme Networks logo are trademarks or registered trademarks of
Extreme Networks, Inc. in the United States and/or other countries.
All other names (including any product names) mentioned in this document are the property of
their respective owners and may be trademarks or registered trademarks of their respective
companies/owners.
For additional information on Extreme Networks trademarks, please see:
www.extremenetworks.com/company/legal/trademarks
Overview..............................................................................................................................10
Security Information................................................................................................................................................. 10
Linux Kernel.......................................................................................................................................................... 10
OpenSSL Version............................................................................................................................................... 10
Upgrading ExtremeXOS..........................................................................................................................................10
Stacking: Upgrading from ExtremeXOS 30.2 and Earlier................................................................11
Extended Edge Switching Image Download Issue............................................................................. 11
Newly Purchased Switches Require Software Upgrade.......................................................................... 12
Open vSwitch Database Management Protocol (OVSDB) End of Support.................................. 12
Default ExtremeXOS® Settings.............................................................................................................................12
ExtremeXOS Image File Names...........................................................................................................................16
New and Corrected Features in ExtremeXOS 31.2..................................................................................... 16
ONEPolicy Dynamic ACLs at Authentication.......................................................................................16
ExtremeSwitching X590 and X690 Series Switches Support Audio Video
Bridging (AVB).................................................................................................................................................... 17
Assisted Replication with Virtual Extensible Local Area Network (VXLAN) Access
Points........................................................................................................................................................................17
Ability to Enable or Disable Source Routing IP Option in the IPv4 Packet Header.......... 18
Edge Automation............................................................................................................................................... 18
Internet Protocol Security (IPsec) Authentication of OSPFv3.................................................... 19
Revocation Check for Certificate Signing Request (CSR)-Generated Switch
Certificate ............................................................................................................................................................ 20
ExtremXOS IP Network Address Translation (NAT)........................................................................20
ExtremeSwitching 5520 Supports Extended Edge Switching Rings......................................22
Port-Specific VLAN Tag (PSTag) Support for Virtual Extensible LAN (VXLAN)
Tenant VLANs..................................................................................................................................................... 23
Port-Specific Tag (PSTag) Support on ExtremeSwitching X695 and 5520 Series
Switches.................................................................................................................................................................23
Network Time Protocol (NTP) Support on ExtremeSwitching X435 Series Switches... 23
Limits................................................................................................................................... 29
Limits Overview.......................................................................................................................................................... 29
Value Edge License Limits......................................................................................................................................31
Edge License Limits................................................................................................................................................. 43
Advanced Edge and Base License Limits...................................................................................................... 72
Core and Premier License Limits....................................................................................................................... 78
Notes for Limits Tables........................................................................................................................................... 84
Conventions
This section discusses the conventions used in this guide.
Text Conventions
Unless otherwise noted, information in this document applies to all supported environments for the
products in question. Exceptions, like command keywords associated with a specific software version,
are identified in the text.
When a feature, function, or operation pertains to a specific hardware product, the product name is
used. When features, functions, and operations are the same across an entire product family, such as
ExtremeSwitching switches or SLX routers, the product is referred to as the switch or the router.
Table 2: Text
Convention Description
screen displays This typeface indicates command syntax, or represents information as
it appears on the screen.
The words enter and type When you see the word enter in this guide, you must type something,
and then press the Return or Enter key. Do not press the Return or
Enter key when an instruction simply says type.
Key names Key names are written in boldface, for example Ctrl or Esc. If you must
press two or more keys simultaneously, the key names are linked with a
plus sign (+). Example: Press Ctrl+Alt+Del
Words in italicized type Italics emphasize a point or denote new terms at the place where they
are defined in the text. Italics are also used when referring to
publication titles.
New information. In a PDF, this is searchable text.
Platform-Dependent Conventions
Unless otherwise noted, all information applies to all platforms supported by ExtremeXOS software,
which are the following:
• ExtremeSwitching® switches
• SummitStack™
When a feature or feature implementation applies to specific platforms, the specific platform is noted in
the heading for the section describing that implementation in the ExtremeXOS command
documentation (see the Extreme Documentation page at www.extremenetworks.com/
documentation/). In many cases, although the command is available on all platforms, each platform
uses specific keywords. These keywords specific to each platform are shown in the Syntax Description
and discussed in the Usage Guidelines sections.
Terminology
When features, functionality, or operation is specific to a switch family, such as ExtremeSwitching, the
family name is used. Explanations about features and operations that are the same across all product
families simply refer to the product as the switch.
Providing Feedback
The Information Development team at Extreme Networks has made every effort to ensure the accuracy
and completeness of this document. We are always striving to improve our documentation and help
you work better, so we want to hear from you. We welcome all feedback, but we especially want to
know about:
• Content errors, or confusing or conflicting information.
• Improvements that would help you find relevant information in the document.
• Broken links or usability issues.
Provide the publication title, part number, and as much detail as possible, including the topic heading
and page number if applicable, as well as your suggestions for improvement.
Getting Help
If you require assistance, contact Extreme Networks using one of the following methods:
Extreme Portal
Search the GTAC (Global Technical Assistance Center) knowledge base; manage support cases and
service contracts; download software; and obtain product licensing, training, and certifications.
The Hub
A forum for Extreme Networks customers to connect with one another, answer questions, and share
ideas and feedback. This community is monitored by Extreme Networks employees, but is not
intended to replace specific guidance from GTAC.
Call GTAC
For immediate support: (800) 998 2408 (toll-free in U.S. and Canada) or 1 (408) 579 2826. For the
support phone number in your country, visit: www.extremenetworks.com/support/contact
Before contacting Extreme Networks for technical support, have the following information ready:
• Your Extreme Networks service contract number, or serial numbers for all involved Extreme
Networks products
• A description of the failure
• A description of any actions already taken to resolve the problem
• A description of your network environment (such as layout, cable type, other relevant environmental
information)
• Network load at the time of trouble (if known)
• The device history (for example, if you have returned the device before, or if this is a recurring
problem)
• Any related RMA (Return Material Authorization) numbers
1. Go to The Hub.
2. In the list of categories, expand the Product Announcements list.
3. Select a product for which you would like to receive notifications.
4. Select Subscribe.
5. To select additional products, return to the Product Announcements list and repeat steps 3 and 4.
Related Publications
ExtremeXOS Publications
• ACL Solutions Guide
• ExtremeXOS 31.2 Command Reference Guide
• ExtremeXOS 31.2 Feature License Requirements
• ExtremeXOS 31.2 User Guide
• ExtremeXOS Quick Guide
• ExtremeXOS Release Notes
• Extreme Hardware/Software Compatibility and Recommendation Matrices
• Extreme Optics Compatibility
These release notes document ExtremeXOS 31.2, which adds features and resolves software
deficiencies.
Security Information
The following section covers important security information for ExtremeXOS 31.2.
Linux Kernel
ExtremeXOS 31.2 uses Linux Kernel 4.14.
OpenSSL Version
ExtremeXOS 31.2 uses FIPS openssl-fips-2.0.16.
Upgrading ExtremeXOS
For instructions about upgrading ExtremeXOS software, see "Software Upgrade and Boot Options" in
the ExtremeXOS 31.2 User Guide.
Beginning with ExtremeXOS 12.1, an ExtremeXOS core image (.xos file) must be downloaded and
installed on the alternate (non-active) partition. If you try to download to an active partition, the error
message Error: Image can only be installed to the non-active partition.
appears. An ExtremeXOS modular software package (.xmod file) can still be downloaded and installed
on either the active or alternate partition.
For more information about manual upgrades, see the Manual Upgrading section in the Extended Edge
Switching Chapter in the ExtremeXOS 31.2 User Guide.
After this one-time upgrade, you can perform all subsequent ExtremeXOS upgrades automatically
using the .lst file. For more information about automatic upgrades, see the Automatic Upgrading
section in the Extended Edge Switching Chapter in the ExtremeXOS 31.2 User Guide.
If you attempt the upgrade with the .lst file, and the following error occurs:
# download image 192.0.2.99 onie-30.4.1.2-vpex_controlling_bridge.lst
Note: The inactive partition (secondary) will be used for installation.
Downloading tftp://192.0.2.99/onie-30.4.1.2-vpex_controlling_bridge.lst
.................
Extracting /scratch/dnld/onie-30.4.1.2.xos from tftp://192.0.2.99/onie-30.4.1.2-
vpex_controlling_bridge.lst
Error: Cannot install /scratch/dnld/onie-30.4.1.2.xos. [Errno 28] No space left on device
Retry the upgrade using the manual upgrade procedure described above.
If manual installation of the .xos or .xmod file fails with the same error, the .lst file may still be
present. To remove this file, use the following command before retrying the manual upgrade procedure:
# run script shell.py "rm /scratch/dnld/*"
For information about upgrading the ExtremeXOS software, see the ExtremeXOS Upgrade Process
topic in the Software Upgrade and Boot Options chapter of the ExtremeXOS 31.2 User Guide.
For users interested in using OVSDB, the most stable version of ExtremeXOS for OVSDB support is 16.2.
a If you choose enhanced security mode when initially setting up the switch or after running unconfigure switch all.
The dynamic policy ACL feature uses the existing RADIUS Access-Accept and change of authorization
(CoA) mechanism to override existing policy rules associated with a user by including a new vendor
specific attribute (VSA) in the CoA and Access-Accept. When a CoA request or Access-Accept
response to apply a particular set of match conditions and actions (or an action-set) is received, a look-
up is performed to determine which policy profile the specified user was authenticated in, and the
action-set ID specified in the CoA/Access-Accept is applied in that user’s profile.
Supported Platforms
ExtremeSwitching X450-G2, X460-G2, X670-G2, X440-G2, X465, X590, X620, X690, X695, X870, 5520
series switches.
Limitations
• ACL style policy must be selected.
• Only a subset of the existing policy rules is allowed.
• SNMP is not supported.
ExtremeSwitching X590 and X690 Series Switches Support Audio Video Bridging
(AVB)
ExtremeXOS 31.2 provides support for Audio Video Bridging (AVB) on ExtremeSwitching X590 and
X690 series switches
AVB supports the deployment of professional quality audio and/or video (AV) over standard Ethernet,
while coexisting with other "legacy" (or non-AV) Ethernet traffic. This supports network convergence by
using one simple standard Ethernet network for all communication needs.
The ExtremeSwitching X590, X690, X870, X695, and 5520 series switches have the AVB Feature
License included in the Advanced Edge or Base License. You do not need to separately purchase and
install the AVB Feature License for these switches.
Supported Platforms
ExtremeSwitching X440-G2, X450-G2, X460-G2, X465, X590, X620, X670-G2, X690, X695, X870, 5520
series switches.
Assisted Replication with Virtual Extensible Local Area Network (VXLAN) Access
Points
ExtremeXOS 31.2 adds support for access points (APs) to the Assisted Replication feature.
Assisted replication is a feature within a virtual extensible local area network (VXLAN) environment that
improves efficiency of broadcast, unknown unicast, and multicast (BUM) traffic handling. More
specifically, assisted replication only modifies the forwarding behavior of BUM traffic. Similar to regular
Assisted Replication functionality, the role of the replicator in an AP topology includes replicating BUM
traffic on behalf of the sending VXLAN VTEP (AP in this case).
Supported Platforms
ExtremeSwitching X465, X590, X670-G2, X690, X695, X870, 5520 series switches.
Ability to Enable or Disable Source Routing IP Option in the IPv4 Packet Header
ExtremeXOS 31.2 re-introduces the ability to enable or disable the processing of the loose source route
or strict source route IP option in the IPv4 packet header.
Supported Platforms
ExtremeSwitching X435, X450-G2, X460-G2, X670-G2, X440-G2, X465, X590, X620, X690, X695,
X870, and 5520 series switches.
Edge Automation
The Edge Automation feature was released in ExtremeXOS 31.1 as a demonstration feature that was
provided for testing purposes. For ExtremeXOS 31.2, this feature is now fully supported.
Edge Automation connects Extreme virtual tunnel endpoints (VTEPs) with other network devices, such
as switches or wireless access points (APs), by establishing a VXLAN tunnel to them, thereby receiving
VXLAN-encapsulated traffic from the devices. Virtual networks and local tunnel endpoints (LTEPs) must
already be configured on the VTEPs, and only remote virtual tunnel endpoint (RTEP) creation is
dynamic.
The information about the devices (name, IP address, MAC address, etc.) is stored in a VNI-device
database. The name of this VNI-device database is set using ExtremeXOS commands or ExtremeCloud
Connector.
Supported Platforms
Edge Automation is a platform-independent feature, and thus works on all platforms that support
VXLAN:
ExtremeSwitching X465, X590, X670-G2, X690, X695, X870, and 5520 series switches.
Limitations
• Virtual networks and LTEPs are not configured automatically. They must be configured using
existing methods.
• The VNI-device database must be reachable using Mgmt-VR.
• You can create multiple databases, but only one can be connected at a time. You can switch
between databases by disconnecting one and connecting to the other.
• Before deleting a databse, you must disconnect it from Edge Automation.
• This feature works only with Extreme Campus Controller. It does not work with any third-party
applications.
• Any existing limitations on dynamic RTEPs apply to RTEPs created by Edge Automation.
• If a database's password is changed, and if the same is configured on ExtremeXOS, then the
connection between ExtremeXOS and the database is re-established, causing a brief loss of
connectivity.
• If a network device supports multiple IP addresses, the first IPv4 address is used for RTEP creation.
• Traffic between ExtremeXOS and the database is unencrypted.
CLI Commands
create database database_name
IPsec is a framework for ensuring secure private communication over IP networks and is based on
standards developed by the International Engineering Task Force (IETF). IPsec provides security
services at the network layer of the Open Systems Interconnection (OSI) model by enabling a system to
select required security protocols, determine the algorithms to use for the security services, and
implement any cryptographic keys required to provide the requested services. IPsec can be used to
protect one or more paths between a pair of hosts, between a pair of security gateways (such as
switches), or between a security gateway and a host.
Supported Platforms
ExtremeSwitching X440-G2, X450-G2, X460-G2, X465, X590, X620, X670-G2, X690, X695, 5520 series
switches.
Supported Platforms
ExtremeSwitching X435, X440-G2, X450-G2, X460-G2, X465, X590, X620, X670-G2, X690, X695,
X870, and 5520 series switches.
Supported Platforms
ExtremeSwitching X465, X590, X690, X695, and X870 series switches.
Limitations
• NAT is supported for IPv4 packets only. NAT is not supported for IPv6 packets.
• NAT is not supported for IPv4 or IPv6 multicast packets.
• Application Level Gateways (ALG) is not supported.
NAT translates IP address of an IPv4 unicast packet, and possibly TCP/UDP port in the TCP/UDP
header. The contents of the payload are not modified. If IP address or L4 port are present in the
payload of the packets, these fields are not modified. If the payload contents are to be modified,
specific ALGs are required. Examples of protocols that require ALG, are File Transfer Protocol (FTP),
Session Initiation Protocol (SIP), Real Time Streaming Protocol (RTSP), BitTorrent, Domain Name
System (DNS), etc.
• Network Address Port Translation (NAPT) does not work with fragmented IP packets, and these are
dropped when NAT is enabled. This is because the fragmented IP packet does not contain a valid
TCP/UDP header, unless it is the first fragment.
• Twice-NAT (NAT where both source and destination IP addresses are translated) are not supported.
disable ip nat
show ip nat
Since the bridge port extenders (BPEs) are managed like slots in a chassis under a single management
domain, multiple layers of a traditional network can be reduced from a configuration and management
perspective, greatly simplifying the network operation.
Extended Edge Switching rings allow two Extended Edge Switching (VPEX) cascades to be joined
together to form a control plane ring. If a link breaks or a bridge port extender (BPE) otherwise leaves,
the remaining BPEs reform two data plane cascades, thus keeping both control and data plane
connectivity to the controlling bridge (CB) alive.
ExtremeXOS 31.2 introduces support for the ExtremeSwitching 5520 series switches for Extended Edge
Switching rings.
Supported Platforms
ExtremeSwitching X670-G2, X465, X590, X690, and 5520 series switches.
Limitations
A maximum of 8 BPEs per ring is supported.
Port-Specific VLAN Tag (PSTag) Support for Virtual Extensible LAN (VXLAN) Tenant
VLANs
The port-specific (PSTag) VLAN tag allows tagged VLAN ports to be configured with tag values. When
the tag is not configured, it is implicit that the tag of the tagged port is the tag of the VLAN. We call the
tag of the port the "port tag", and the tag of the VLAN the "base tag". The port tag is used to determine
the eligibility of the frames allowed to be part of the VLAN. Once the frame is admitted to the VLAN
port, the base tag is used. From a functional standpoint, the frame tag is rewritten to the base tag.
ExtremeXOS 31.2 adds support for Virtual Extensible LAN (VXLAN) adding and deleting PSTag ports for
Tenant VLANs.
Supported Platforms
ExtremeSwitching X670-G2, X465, X870, X690, X590, X695, and 5520 series switches.
ExtremeXOS 31.2 adds PSTag support to the ExtremeSwitching X695 and 5520 series switches.
Supported Platforms
ExtremeSwitching X460-G2, X670-G2, X465, X870, X690, X590, X695, and 5520 series switches.
ExtremeXOS 31.2 adds NTP support for ExtremeSwitching X435 series switches.
Supported Platforms
ExtremeSwitching X435, X440-G2, X450-G2, X460-G2, X465, X590, X620, X670-G2, X690, X695,
X870, and 5520 series switches.
of those capabilities, and the identification of the station's point of attachment to the 802 LAN required
by those management entity or entities.
ExtremeXOS 31.2 introduces support for LLDP on the switch management port.
Supported Platforms
ExtremeSwitching X435, X440-G2, X450-G2, X460-G2, X465, X590, X620, X670-G2, X690, X695,
X870, and 5520 series switches.
Limitations
Standard TLVs are supported. No support is provided for vendor-specific and MED TLVs.
Supported Platforms
ExtremeSwitching X435, X440-G2, X450-G2, X460-G2, X465, X590, X620, X670-G2, X690, X695,
X870, 5520 series switches.
Supported Platforms
ExtremeSwitching X670-G2, X870, X690, X590, X695, X465 series switches.
Limitations
This feature has the following limitations:
• Supported only for overlay BUM traffic.
• Supported only with PIM-SSM.
• BUD node operation is not supported with MLAG.
• Multicast group range used for this feature cannot be configured/used for regular multicast traffic.
Note
This feature should not be used with Assisted Replication.
New ExtremeSwitching 5520 switches include a Factory Default (Evaluation) License to use all features
(excluding MACsec). This Evaluation license is equivalent to a Premier license. You can configure all
features, except MACsec, without restrictions and save the configuration. The evaluation periods was
restricted to 30 days, and if after 30 days you did not obtain and installed a Premier license, and if you
rebooted the switch, the switch will effectively have only Base license capabilities.
This enhancements allows you to extended the evaluation period by three more 30-day periods using a
CLI command (see below).
Supported Platforms
ExtremeSwitching 5520 series switches.
Supported Platforms
ExtremeSwitching X435, X450-G2, X460-G2, X670-G2, X440-G2, X465, X590, X620, X690, X695,
X870, 5520 series switches.
The Extreme Optics Compatibility website displays supported hardware platforms, technical
specifications, and usage considerations for pluggable optical devices (transceivers and cables) used in
all Extreme Networks operating environments. To access the site, open https://
optics.extremenetworks.com/EXOS/ in a web browser.
To find the recommended EXOS releases for EXOS-based hardware platforms, see ExtremeXOS Release
Recommendations.
The latest versions of this and other ExtremeXOS guides are at: www.extremenetworks.com/
documentation/.
Supported MIBs
The Extreme Networks management information bases (MIBs) are located at
www.extremenetworks.com/support/policies/mibs/.
When you provide your serial number or agreement number, the MIBs are available under each release.
For detailed information on which MIBs and SNMP traps are supported, see the Extreme Networks
Proprietary MIBs and MIB Support Details sections in the ExtremeXOS 31.2 User Guide.
Limits Overview
The limits data is grouped by license level that contains the associated features:
• Value Edge License Limits on page 31
• Edge License Limits on page 43
• Advanced Edge and Base License Limits on page 72
• Core and Premier License Limits on page 78
The ExtremeSwitching family of switches includes two categories of switches with different license
levels:
Note: * The X435 is the only switch that supports the Value Edge license level.
The following figure illustrates that each license level builds on the features of the license level below it.
For example, the Advanced Edge license includes all of the features in the Edge license, plus the
features in the Advance Edge license level.
Premier = Core
For more information about licenses, see ExtremeXOS 31.2 Feature License Requirements.
The following tables summarize tested metrics for a variety of features, as measured in a per-system
basis unless otherwise noted. These limits may change, but represent the current status. The contents of
this table supersede any values mentioned in the ExtremeXOS books.
The scaling and performance information shown in the following tables is provided for the purpose of
assisting with network design. It is recommended that network architects and administrators design
and manage networks with an appropriate level of network scaling “head room.” The scaling and
performance figures provided have been verified using specific network topologies using limited switch
configurations. There is no guarantee that the scaling and performance figures shown are applicable to
all network topologies and switch configurations and are provided as a realistic estimation only. If you
experience scaling and performance characteristics that you feel are sufficiently below what has been
documented, contact Extreme Networks technical support for additional assistance.
The route limits shown in the following tables for IPv4 and IPv6 routing protocols are software limits
only. The actual hardware limits may be higher or lower than the software limits, based on platform. The
hardware limits for specific platforms are specified as "IPv4/IPv6 routes (LPM entries in hardware)" in
the following tables.
In the Extended Edge Switching architecture, Layer-2, Layer-3, and multicast packet forwarding and
filtering operations take place on the controlling bridge. The controlling bridge switch and attached
BPEs (V400 Virtual Port Extenders) constitute a single, extended switch system. Therefore, the
Extended Edge Switching system assumes the scale and limits from the specific controlling bridge
model (for example, Extended Edge Switching X670-G2 series switches) in use. For applicable limits,
see the following tables for the controlling bridge you are using.
Note:
• The internal lookup table
configuration used is "l2-and-
l3”.
• IPv6 and IPv4 L2 IPMC scaling is
the same for this mode.
• Layer-2 IPMC forwarding cache
limits—(IGMP/MLD/PIM
snooping) in mixed-mode are
the same.
Note:
• Limit value is the same for MVR
senders, PIM Snooping entries.
PIM SSM cache, IGMP senders,
PIM cache.
• The internal lookup table
configuration used is "more l3-
and-ipmc”.
• Assumes source-group-vlan
mode as look up key.
• Layer 3 IPMC cache limit in
mixed mode also has the same
value.
Note:
• Limit value is the same for MLD
sender per switch, PIM IPv6
cache.
• The internal lookup table
configuration used is "more l3-
and-ipmc”.
• Assumes source-group-vlan
mode as lookup key.
ExtremeSwitching X620
ExtremeSwitching X870
ExtremeSwitching X620 15
ExtremeSwitching X870 127
ExtremeSwitching X590, 35
ExtremeSwitching X465 55
ExtremeSwitching 5520 59
MLAG peers—maximum number of ExtremeSwitching X450-G2, X460-G2, X670-G2, 2
MLAG peers allowed. X620, X440-G2, X870, X690, X590, X465, X695,
5520
MPLS RSVP-TE interfaces— ExtremeSwitching X460-G2, X670-G2, X590, 32
maximum number of interfaces. X465, X870
ExtremeSwitching X450-G2, X440-G2, X620, N/A
X695, 5520
MPLS RSVP-TE ingress LSPs— ExtremeSwitching X460-G2, X670-G2, X870, 2,000
maximum number of ingress LSPs. X590,X690, X465
ExtremeSwitching X450-G2, X440-G2, X620, N/A
X695, 5520
MPLS RSVP-TE egress LSPs— ExtremeSwitching X460-G2, X670-G2, X870, 2,000
maximum number of egress LSPs. X690 X590, X465
ExtremeSwitching X450-G2, X440-G2, X620, N/A
X695, 5520
MPLS RSVP-TE transit LSPs— ExtremeSwitching X460-G2, X670-G2 2,000
maximum number of transit LSPs.
ExtremeSwitching X870, X690, X590, X465 4,000
ExtremeSwitching X450-G2, X440-G2, X620, N/A
X695, 5520
MPLS RSVP-TE paths—maximum ExtremeSwitching X460-G2 1,000
number of paths.
ExtremeSwitching X670-G2, X870, X690, X590, 2,000
X465
ExtremeSwitching X450-G2, X440-G2, X620, N/A
X695, 5520
MPLS RSVP-TE profiles—maximum ExtremeSwitching X460-G2 1,000
number of profiles.
ExtremeSwitching X670-G2, X870, X690 X590, 2,000
X465
ExtremeSwitching X450-G2, X440-G2, X620, N/A
X695, 5520
BGP auto-peering maximum IPv6 ExtremeSwitching X670-G2, X690, X870, X590, 8,000
prefixes with ECMP—Maximum X465, X695
number of IPv6 Network prefixes
with ECMP. ExtremeSwitching 5520 254
Table 9: Supported Limits for Advanced Edge and Base License (continued)
Metric Product Limit
EAPSv2 protected VLANs— ExtremeSwitching X450-G2, X460-G2, X670-G2, 500
maximum number of protected X440-G2, X620, 5520
VLANs.
ExtremeSwitching X870, X690, X590, X465, 2,000
X695
ERPS domains—maximum number ExtremeSwitching X450-G2, X460-G2, X670-G2, 32
of ERPS domains without CFM X620, X440-G2, X870, X690, X590, X465, X695,
configured. 5520
ERPS domains—maximum number ExtremeSwitching X450-G2, X670-G2, X620, 16
of ERPS domains with CFM X870, X690, X590, X465, X695, 5520
configured.
ExtremeSwitching X460-G2 32
ERPSv1 protected VLANs— ExtremeSwitching X450-G2, X460-G2, X670-G2, 2,000
maximum number of protected X870, X690, X590, X465, X695, 5520
VLANs.
ExtremeSwitching X620, X440-G2 1,000
ERPSv2 protected VLANs— ExtremeSwitching X450-G2, X460-G2, X670-G2, 2,000
maximum number of protected X870, X690, X590, X465, X695, 5520
VLANs.
ExtremeSwitching X620, X440-G2 500
ESRP groups—maximum number ExtremeSwitching X450-G2, X460-G2, X670-G2, 32
of ESRP groups X440-G2, X620, X870, X690, X590, X465, X695,
5520
ESRP domains—maximum number ExtremeSwitching X450-G2, X460-G2, X670-G2, 64
of ESRP domains. X620, X440-G2, X870, X690, X590, X465, X695,
5520
ESRP L2 VLANs—maximum ExtremeSwitching X450-G2, X460-G2, X670-G2, 1,000
number of ESRP VLANs without an X620, X440-G2, X870, X690, X590, X465, X695,
IP address configured. 5520
ESRP L3 VLANs—maximum ExtremeSwitching X450-G2, X460-G2, X670-G2, 511
number of ESRP VLANs with an IP X620, X440-G2, X870, X690, X590, X465, X695,
address configured. 5520
ESRP (maximum ping tracks)— ExtremeSwitching X450-G2, X460-G2, X670-G2, 8
maximum number of ping tracks X620, X440-G2, X870, X690, X590, X465, X695,
per VLAN. 5520
ESRP (IP route tracks)—maximum ExtremeSwitching X450-G2, X460-G2, X670-G2, 8
IP route tracks per VLAN. X620, X440-G2, X870, X690, X590, X465, X695,
5520
ESRP (VLAN tracks)—maximum ExtremeSwitching X450-G2, X460-G2, X670-G2, 1
number of VLAN tracks per VLAN. X620, X440-G2, X870, X690, X590, X465, X695,
5520
OSPFv2/v3 ECMP—maximum ExtremeSwitching X460-G2, X670-G2, X450-G2, 64
number of equal cost multipath X870, X690, X590, X465, X695
OSPFv2 and OSPFv3.
ExtremeSwitching X620 4
ExtremeSwitching 5520 8
ExtremeSwitching X440-G2 N/A
Table 9: Supported Limits for Advanced Edge and Base License (continued)
Metric Product Limit
OSPFv2 areas—as an ABR, how ExtremeSwitching X460-G2, X670-G2, X870, 8
many OSPF areas are supported X690, X590, X465, X695, 5520
within the same switch.
ExtremeSwitching X450-G2, X440-G2, X620 4
OSPFv2 external routes— ExtremeSwitching X870, X690, X590, X465, 10,000
recommended maximum number X695
of external routes contained in an
OSPF LSDB. ExtremeSwitching X670-G2, X460-G2, 5520 5,000
ExtremeSwitching X450-G2, X440-G2, X620 2,400
OSPFv2 inter- or intra-area routes ExtremeSwitching X870, X690, X590, X465, 4,000
—recommended maximum number X695
of inter- or intra-area routes
contained in an OSPF LSDB with ExtremeSwitching X670-G2, X460-G2, 5520 2,000
one ABR in OSPF domain. ExtremeSwitching X450-G2, X440-G2, X620 1,000
OSPFv2 interfaces—recommended ExtremeSwitching X450-G2, X460-G2, X670-G2, 4
maximum number of OSPF X620, X440-G2, X870, X690, X590, X465, X695,
interfaces on a switch (active 5520
interfaces only).
OSPFv2 links—maximum number ExtremeSwitching X460-G2, X670-G2, X870, 400
of links in the router LSA. X690, X590, X465, X695, 5520
ExtremeSwitching X450-G2, X620, X440-G2 4
Table 9: Supported Limits for Advanced Edge and Base License (continued)
Metric Product Limit
OSPFv3 interfaces—maximum ExtremeSwitching X670-G2, X460-G2, X450-G2, 4
number of OSPFv3 interfaces X870, X690, X440-G2, X620, X590, X465, X695,
(active interfaces only). 5520
OSPFv3 neighbors—maximum ExtremeSwitching X450-G2, X670-G2, X460-G2, 4
number of OSPFv3 neighbors. X870, X690, X440-G2, X620, X590, X465, X695,
5520
OSPFv3 virtual links—maximum ExtremeSwitching X670-G2, X460-G2, X870, 16
number of OSPFv3 virtual links X690, X590, X465, X695, 5520
supported.
ExtremeSwitching X450-G2, X440-G2, X620 4
PIM IPv4 (maximum interfaces)— ExtremeSwitching X460-G2, X670-G2, X450-G2, 4
maximum number of PIM active X870, X440-G2, X620, X690, X590, X465, X695,
interfaces. 5520
PIM IPv4 Limits—maximum ExtremeSwitching X450-G2, X460-G2, X670-G2, 180
number of multicast groups per X620, X440-G2, X870, X690, X590, X465
dynamic rendezvous point. , X695, 5520
PIM IPv4 Limits—maximum ExtremeSwitching X450-G2, X460-G2, X670-G2, 3,000
number of multicast groups per X620, X440-G2, X870, X690, X590, X465 (depends on
static rendezvous point. , X695, 5520 policy file
limits)
PIM IPv4 Limits—maximum ExtremeSwitching X460-G2, X670-G2, X450-G2, 5,000
number of multicast sources per X870, X690, X590 , X465, X695, 5520
group.
ExtremeSwitching X440-G2, X620 1,500
PIM IPv4 Limits—maximum ExtremeSwitching X450-G2, X460-G2, X670-G2, 145
number of dynamic rendezvous X620, X440-G2, X870, X690, X590 , X465
points per multicast group. , X695, 5520
PIM IPv4 Limits—static rendezvous ExtremeSwitching X450-G2, X460-G2, X670-G2, 32
points. X620, X440-G2, X870, X690, X590 , X465
, X695, 5520
PIM IPv6 (maximum interfaces)— ExtremeSwitching X460-G2, X670-G2, X450-G2, 4
maximum number of PIM active X870, X440-G2, X620, X690, X590 , X465, X695,
interfaces. 5520
PIM IPv6 Limits—maximum ExtremeSwitching X460-G2, X670-G2, X870, 1,750
number of multicast sources per X690, X590 , X465, X695, 5520
group.
ExtremeSwitching X450-G2 1,500
ExtremeSwitching X440-G2, X620 550
PIM IPv6 Limits—maximum ExtremeSwitching X450-G2, X460-G2, X670-G2, 70
number of multicast groups per X620, X440-G2, X870, X690, X590, X465
dynamic rendezvous point. , X695, 5520
PIM IPv6 Limits—maximum ExtremeSwitching X450-G2, X460-G2, X670-G2, 3,000
number of multicast groups per X620, X440-G2, X870, X690, X590, X465 (depends on
static rendezvous point. , X695, 5520 policy file
limits)
Table 9: Supported Limits for Advanced Edge and Base License (continued)
Metric Product Limit
PIM IPv6 Limits—maximum ExtremeSwitching X450-G2, X460-G2, X670-G2, 64
number of dynamic rendezvous X620, X440-G2, X870, X690, X590, X465
points per multicast group. , X695, 5520
PIM IPv6 Limits—maximum ExtremeSwitching X450-G2, X460-G2, X670-G2, 70
number of secondary addresses X620, X440-G2, X870, X690, X590 , X465
per interface. , X695, 5520
PIM IPv6 Limits—static rendezvous ExtremeSwitching X450-G2, X460-G2, X670-G2, 32
points. X620, X440-G2, X870, X690, X590 , X465
, X695, 5520
Port-specific VLAN tags— ExtremeSwitching X460-G2, X670-G2, X770, 1,023
maximum number of port-specific X870, X690, X590 , X465, 5520, X695
VLAN tags.
ExtremeSwitching X450-G2, X440-G2, X620 N/A
Port-specific VLAN tags— ExtremeSwitching X460-G2, X670-G2, X870, 4,000
maximum number of port-specific X690, X590, X465, 5520, X695
VLAN tag ports.
ExtremeSwitching X450-G2, X440-G2, X620 N/A
VRRP (v2/v3-IPv4) (maximum Normal Mode (as individual VRs):
instances)—maximum number of
VRRP instances for a single switch, ExtremeSwitching X670-G2, X460-G2, X450-G2, 511
with Advanced Edge license or X870, X690, X590, X465, X695, 5520
higher. ExtremeSwitching X440-G2, X620 128
Note: These limits are applicable Scaled Mode (with groups):
for Fabric Routing configuration
ExtremeSwitching X670-G2, X460-G2, X450-G2, 2,048
also.
X870, X690, X590, X465, X695, 5520
Note: Number of groups ExtremeSwitching X440-G2, X620 128
configured should not exceed the Sliced Mode:
number of individual VRs
supported (that is, in normal mode) ExtremeSwitching 5520 511
for that platform type.
Table 9: Supported Limits for Advanced Edge and Base License (continued)
Metric Product Limit
VRRP (v2/v3-IPv4/IPv6) ExtremeSwitching X670-G2, X460-G2, X450-G2 255
(maximum VRID)—maximum X440-G2, X620, X870, X690, X590, X465, X695,
number of unique VRID numbers 5520
per switch.
Note: With Advanced Edge license or higher.
Table 9: Supported Limits for Advanced Edge and Base License (continued)
Metric Product Limit
VXLAN—maximum tenant VLANs ExtremeSwitching X670-G2, X870, X690, X590, 4,096
plus port combinations X465, X695, 5520
Note: Every FDB entry configured ExtremeSwitching X460-G2, X450-G2, X440-G2, N/A
reduces this limit by 1. X620
Table 10: Supported Limits for Core and Premier License (continued)
Metric Product Limit
BGP (peers)—maximum number of ExtremeSwitching X460-G2, X670-G2, X870, 128
BGP peers. 5520
Note: With default keepalive and ExtremeSwitching , X590, X465, X695 300
hold timers. ExtremeSwitching X450-G2 100
Table 10: Supported Limits for Core and Premier License (continued)
Metric Product Limit
BGPv6 (unicast address-family ExtremeSwitching X460-G2, 5520 6,000
routes)—maximum number of
unicast address family routes. ExtremeSwitching X670-G2 8,000
ExtremeSwitching X870, X690, X590, X465, 10,000
X695
ExtremeSwitching X870, X690 (with ALPM 100,000
enabled)
ExtremeSwitching X450-G2 4,800
ExtremeSwitching 5520 (with ALPM enabled) 40,000
BGPv6 (non-unique routes)— ExtremeSwitching X460-G2, 5520 18,000
maximum number of non-unique
BGP routes. ExtremeSwitching X670-G2, X870, X690, X590, 24,000
X465, X695
ExtremeSwitching X450-G2 14,000
EVPN EVI instances—maximum ExtremeSwitching X670-G2, X870, X690, X590, 1,024
number of EVI instances. X465, X695, 5520
EVPN LAGs—maximum number of ExtremeSwitching X670-G2, X870, X690, X590, 128
LAGs. X465, X695
GRE Tunnels—maximum number of ExtremeSwitching X460-G2, X670-G2, X450-G2, 255
GRE tunnels. X870, X690, X590, X465 , X695, 5520
ExtremeSwitching X620, X440G2 N/A
IS-IS adjacencies—maximum ExtremeSwitching X460-G2, X670-G2, X870, 128
number of supported IS-IS X690, X590, X465, X695, 5520
adjacencies.
ExtremeSwitching X450-G2 N/A
IS-IS ECMP—maximum number of ExtremeSwitching X460-G2, X670-G2, X870, 2, 4, or 8
equal cost paths per multipath for X690, X590, X465, X695, 5520
IS-IS.
ExtremeSwitching X450-G2 N/A
IS-IS interfaces—maximum number ExtremeSwitching X460-G2, X670-G2, X770, 255
of interfaces that can support IS-IS. X870, X690, X590, X465, X695, 5520
ExtremeSwitching X450-G2 N/A
IS-IS routers in an area— ExtremeSwitching X460-G2, X670-G2, X870, 256
recommended maximum number X690, X590, X465, X695, 5520
of IS-IS routers in an area.
ExtremeSwitching X450-G2 N/A
IS-IS route origination— ExtremeSwitching X460-G2, X670-G2, X870, 20,000
recommended maximum number X690, X590, X465, X695, 5520
of routes that can be originated by
an IS-IS node. ExtremeSwitching X450-G2 N/A
Table 10: Supported Limits for Core and Premier License (continued)
Metric Product Limit
IS-IS IPv4 L2 routes— ExtremeSwitching X460-G2, X670-G2, X870, 25,000
recommended maximum number X690, X590, X465, X695, 5520
of IS-IS Level 2 routes.
ExtremeSwitching X450-G2 N/A
IS-IS IPv4 L1 routes in an L1/L2 ExtremeSwitching X460-G2, X670-G2, X870, 20,000
router—recommended maximum X690, X590, X465, X695, 5520
number of IS-IS Level 1 routes in an
L1/L2 IS-IS router. ExtremeSwitching X450-G2 N/A
Table 10: Supported Limits for Core and Premier License (continued)
Metric Product Limit
MSDP maximum mesh groups— ExtremeSwitching X450-G2, X670-G2, X460-G2, 16
maximum number of MSDP mesh X870, X690, X590, X465, X695, 5520
groups.
OSPFv2/v3 ECMP—maximum ExtremeSwitching X460-G2, X670-G2, X450-G2, 64
number of equal cost multipath X870, X690, X590, X465, X695, 5520
OSPFv2 and OSPFv3.
ExtremeSwitching 5520 8
OSPFv2 areas—as an ABR, how ExtremeSwitching X450-G2, X460-G2, X670-G2, 8
many OSPF areas are supported X870, X690, X590, X465, X695, 5520
within the same switch.
OSPFv2 external routes— ExtremeSwitching X870, X690, X590, X465, 10,000
recommended maximum number X695
of external routes contained in an
OSPF LSDB. ExtremeSwitching X670-G2, X460-G2, 5520 5,000
ExtremeSwitching X450-G2 4,000
OSPFv2 inter- or intra-area routes ExtremeSwitching X870, X690, X590, X465, 4,000
—recommended maximum number X695
of inter- or intra-area routes
contained in an OSPF LSDB with ExtremeSwitching X670-G2, X460-G2, 5520 2,000
one ABR in OSPF domain. ExtremeSwitching X450-G2 1,600
OSPFv2 interfaces—recommended ExtremeSwitching X460-G2, X670-G2, X870, 400
maximum number of OSPF X690, X590, X465, X695, 5520
interfaces on a switch (active
interfaces only). ExtremeSwitching X450-G2 320
Table 10: Supported Limits for Core and Premier License (continued)
Metric Product Limit
OSPFv3 external routes— ExtremeSwitching X670-G2, X460-G2, X870, 10,000
recommended maximum number X690, X590, X465, X695, 5520
of external routes.
ExtremeSwitching X450-G2 7,500
OSPFv3 inter- or intra-area routes ExtremeSwitching X870, X690, X590, X465, 4.000
—recommended maximum number X695
of inter- or intra-area routes.
ExtremeSwitching X670-G2, X460-G2, 5520 3,000
ExtremeSwitching X450-G2 500
OSPFv3 interfaces—maximum
number of OSPFv3 interfaces ExtremeSwitching X670-G2, X460-G2, X870, 256
(active interfaces only). X690, X590, X465, X695
ExtremeSwitching X450-G2 192
ExtremeSwitching 5520 4
OSPFv3 neighbors—maximum ExtremeSwitching X670-G2, X460-G2, X870, 64
number of OSPFv3 neighbors. X690, X590, X465, X695, 5520
ExtremeSwitching X450-G2 48
OSPFv3 virtual links—maximum ExtremeSwitching X670-G2, X460-G2, X870, 16
number of OSPFv3 virtual links X690, X590, X465, X695, 5520
supported.
ExtremeSwitching X450-G2 12
PIM IPv4 (maximum interfaces)— ExtremeSwitching X450-G2, X460-G2, X670-G2, 255
maximum number of PIM active X870, X690, X590, X465, X695, 5520
interfaces.
PIM IPv4 Limits—maximum ExtremeSwitching X450-G2, X460-G2, X670-G2, 180
number of multicast groups per X870, X690, X590 , X465, X695, 5520
dynamic rendezvous point.
PIM IPv4 Limits—maximum ExtremeSwitching X450-G2, X460-G2, X670-G2, 3,000
number of multicast groups per X870, X690, X590, X465, X695, 5520 (depends on
static rendezvous point. policy file
limits)
PIM IPv4 Limits—maximum ExtremeSwitching X450-G2, X460-G2, X670-G2, 5,000
number of multicast sources per X870, X690, X590 , X465, X695, 5520
group.
PIM IPv4 Limits—maximum ExtremeSwitching X450-G2, X460-G2, X670-G2, 145
number of dynamic rendezvous X870, X690, X590 , X465, X695, 5520
points per multicast group.
PIM IPv4 Limits—static rendezvous ExtremeSwitching X450-G2, X460-G2, X670-G2, 32
points. X870, X690, X590 , X465, X695, 5520
PIM IPv6 (maximum interfaces)— ExtremeSwitching X450-G2, X460-G2, X670-G2, 255
maximum number of PIM active X870, X690, X590 , X465, X695, 5520
interfaces.
Table 10: Supported Limits for Core and Premier License (continued)
Metric Product Limit
PIM IPv6 Limits—maximum ExtremeSwitching X460-G2, X670-G2, X870, 1,750
number of multicast sources per X690, X590 , X465, X695
group. , 5520
ExtremeSwitching X450-G2, 1,500
PIM IPv6 Limits—maximum ExtremeSwitching X450-G2, X460-G2, X670-G2, 70
number of multicast groups per X870, X690, X590 , X465, X695, 5520
dynamic rendezvous point.
PIM IPv6 Limits—maximum ExtremeSwitching X450-G2, X460-G2, X670-G2, 3,000
number of multicast groups per X870, X690, X590, X465, X695, 5520 (depends on
static rendezvous point. policy file
limits)
PIM IPv6 Limits—maximum ExtremeSwitching X450-G2, X460-G2, X670-G2, 64
number of dynamic rendezvous X870, X690, X590 , X465, X695, 5520
points per multicast group.
PIM IPv6 Limits—maximum ExtremeSwitching X450-G2, X460-G2, X670-G2, 70
number of secondary addresses X870, X690, X590 , X465, X695, 5520
per interface.
PIM IPv6 Limits—static rendezvous ExtremeSwitching X450-G2, X460-G2, X670-G2, 32
points. X870, X690, X590 , X465, X695, 5520
a The table shows the total available. When installing ACL rules bound to a set of ports, rules are replicated for each port if there
are ACL counters and counter compression is not enabled, or if the ports are Extended Edge Switching extended ports.
c When there are BFD sessions with minimal timer, sessions with default timer should not be used.
f Effective capacity varies based on actual MAC addresses and VLAN IDs used and hash algorithm selected.
g Based on "configure forwarding internal-tables more l2".
h Based on "configure forwarding internal-tables more l3-and-ipmc".
j The limit depends on setting configured with configure iproute reserved-entries.
m The IPv4 and IPv6 multicast entries share the same hardware tables, so the effective number of IPv6 multicast entries depends
on the number of IPv4 multicast entries present and vice versa.
n If IGMP and MLD are simultaneously configured on the switch, the number of effective subscribers supported are lessened
accordingly.
o The total of all PBR next hops on all flow redirects should not exceed 4,096.
p The number of XNV authentications supported based on system ACL limitations.
q Based on "configure forwarding internal-tables more routes".
r Based on configure forwarding internal-tables more routes ipv6-mask-length 128.
s Based on configure forwarding internal-tables more l3-and-ipmc or configure
forwarding internal-tables l2-and-l3.
This chapter lists open software issues, limitations in ExtremeXOS system architecture (known issues),
and resolved issues in ExtremeXOS.
Open Issues
The following are new open issues for supported features found in ExtremeXOS 31.2.
Table 11: Open Issues, Platform-Specific, and Feature Change Requests (CRs)
Defect Number Description
Fabric Attach
EXOS-28354 Fabric Attach assignments learned from netlogin FA clients are not
checkpointed to the MLAG peer switch.
Known Behaviors
The following are limitations in ExtremeXOS system architecture that have yet to be resolved.
Table 12: Known Issues, Platform-Specific, and Feature Change Requests (CRs)
Defect Number Description
General
EXOS-27922 Beginning with EXOS 31.2, PTPv2 is not supported on X460-G2 and X670-
G2 switches.
ExtremeXOS 15.4.1, ExtremeXOS 15.5.1, ExtremeXOS 15.5.2, ExtremeXOS 15.6.1, ExtremeXOS 15.6.2,
ExtremeXOS 15.7.1, ExtremeXOS 16.1, ExtremeXOS 16.1.2, ExtremeXOS 16.1.3, ExtremeXOS 21.1,
ExtremeXOS 22.1, ExtremeXOS 22.2, ExtremeXOS 22.3, ExtremeXOS 22.4, ExtremeXOS 22.5,
ExtremeXOS 22.6, ExtremeXOS 30.1, ExtremeXOS 30.2, ExtremeXOS 30.3, ExtremeXOS 30.4,
ExtremeXOS 30.5, ExtremeXOS 30.6, ExtremeXOS 30.7, ExtremeXOS 31.1, and ExtremeXOS 31.2. For
information about those fixes, see the release notes for the specific release.
Table 13: Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in
31.2.1-Patch1-5
Defect Number Description
General
EXOS-28513 dot1x authentication fails when radius challenge packet contains more
attributes in EAP message.
EXOS-28514 VLAN process ends unexpectedly during bootup of a VPEX-enabled switch
with a high number of extended slots.
EXOS-28829 Set the default VPEX IPMC replication mode to controlling-bridge.
EXOS-28828 Multicast traffic loss and Virtual Port (VP) instance-related error messages
observed in VPEX setup.
ExtremeSwitching 5520
EXOS-28791 Switch reboots on license revocation after NOS switch from VOSS to EXOS.
Table 14: Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in
31.2
Defect Number Description
General
EXOS-24249 show netlogin session shows the wrong entry for unauthenticated
user in non-policy mode.
EXOS-27257 The show configuration difference command output incorrectly
shows differences when the booted and the running configuration are
identical.
Table 14: Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in
31.2 (continued)
Defect Number Description
EXOS-27510 After running port statistics-related commands, the CLI stops
responding.
EXOS-27654 Authentication for local user fails for SSH connection, including unreachable
radius server.
EXOS-27693 On upgrade to EXOS 22.7 and later releases, processes like THTTPD are
stuck in the load configuration state if there is a large amount of VLAN
configuration.
EXOS-27746 CLI process consumes more CPU when the enable debug-mode
command is executed and the session times out.
EXOS-27764 EXSH process crashes with signal 6 when issuing a double TAB after alias
name.
EXOS-27795 A short loop is observed in the sharing link when performing a node failover
in the stack.
EXOS-27799 When loopback mode is enabled on the bootp client VLAN, the response is
incorrectly sent to the default route.
EXOS-27829 RTMGR process crashes with signal 6 due to stale BGP entries.
EXOS-28013 LLDP advertise port displays "string" instead of "port" description string.
EXOS-28193 With a newly formed stack, LLDP is disabled for all the slot ports except the
primary slot.
ExtremeSwitching X670-G2 Series Switches
EXOS-27602 Non-partitioned 40G ports in backup/standby slots incorrectly display as
Ready instead of "NP" for not present.
ExtremeSwitching X440 Series Switches
EXOS-27701 On "Admin enable" operation, STP PDU is not sent out immediately if the
edge port is configured with edge safeguard and BPDU restrict is enabled.
ExtremeSwitching X440-G2 Series Switches
EXOS-26563 ExtremeSwitching X440-G2 fan profile causing hyperventilation.
EXOS-27398 Operational Edge port status is incorrectly set to FALSE for 100/10 Mbps
port.
ExtremeSwitching X460-G2 Series Switches
EXOS-27868 The aging value of FDB entries are incorrectly displayed as 0.
EXOS-28075 Two-Way Active Measurement Protocol (TWAMP) feature does not work as
expected in EXOS 30.x.
ExtremeSwitching X465 Series Switches
EXOS-27573 Re-convergence time on an ExtremeSwitching X465 series stack has
increased from ~50 msec in ExtremeXOS 30.7 to greater than 3 seconds in
ExtremeXOS 31.1.
ExtremeSwitching 5520 Series Switches
Table 14: Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in
31.2 (continued)
Defect Number Description
EXOS-27495 Cisco 7821 IP phones might not be able to auto-negotiate to 100Mbps when
connected to 1G copper ports. Instead, the connection occurs at 10Mbps.
EXOS-27571 The ExtremeSwitching 5520 series switches PoE power budget limits have
been reduced for the following PSU configurations:
5520-24W: 2 × 1100W PSUs—PoE budget is reduced from 1,800W to 1,781W
5520-48W: 2 × 2000W PSUs (200–240VAC)—PoE budget is reduced from
3,600W to 3,568W
5520-48W: 2 × 1100W PSUs—PoE budget is reduced from 1,800W to 1,770W
5520-12MW-36W: 2 × 2000W PSUs (200–240VAC)—PoE budget is reduced
from 3,600W to 3,549W
5520-12MW-36W: 2 × 1100W PSUs—PoE budget is reduced from 1,800W to
1,751W
ExtremeXOS 31.1 enforces the previous limits. The new limits are
implemented in ExtremeXOS 31.2.
EXOS-27609 Process OSPFv3 fails after running restart ports all with an OSPFv3
virtual-link configuration on ExtremeSwitching 5520 series.
EXOS-27728 Standalone ExtremeSwitching 5520 series switches should support 32 ports
per load-sharing group. However, currently you cannot create load-sharing
groups with more than 8 ports.
Note: This value is the maximum number of ports allowed in the aggregator.
When you create an LACP LAG or when adding ports to it, twice the
supported value is permitted in the load-sharing group to allow for standby
ports.
EXOS-27860 After switching NOS from EXOS to VOSS and back to EXOS, /
scratch/nos has an unclean .xos image, leading to a "no space" error
during image download.
Extended Edge Switching
EXOS-26582 Multicast traffic loss observed in enterprise bed VPEX ring + MLAG setup.
EXOS-27637 When configuring LAG on extended ports, a short loop is detected in a
switch.
EXOS-27914 VPEX topology is stuck in Severed State after rebooting the V300 Virtual
Port Extender node.
EXOS-27917 VPEX - default Policy consumes excess ACL hardware resources.
EXOS-28076 The nodealias process crashes with signal 11, leading to a switch reboot.
Fabric Attach
EXOS-26121 Dynamic FAMgmt VLAN is not cleared on PROXY when it transitions to
CLIENT.
EXOS-27431 fabric attach management-vlan config is not cleared when FA
mode changes from server to client.
EXOS-27902 When the number of FA elements crosses 20, the show fabric attach
elements output is empty.
SummitStack
Table 14: Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in
31.2 (continued)
Defect Number Description
EXOS-26668 HAL process crashes when the host moves from network VLAN to
subscriber VLAN.
EXOS-26946 An error message appears on both stack primary and backup nodes when a
virtual network with VNID <#> is not found on the backup slot. This occurs
when the client is authenticated and dynamic VNI is created on the stack
node. However, traffic flows in both the directions without issue.
EXOS-27303 Backup node traffic is incorrectly learned on normal VLAN instead of
VXLAN, causing traffic to get dropped on both ingress and egress direction.
EXOS-27767 HAL process ends unexpectedly on the backup node when the standby
node comes back online after a reboot.
Extreme Loop Recovery Protocol (ELRP)
EXOS-26746 Inter-VLAN loop is not detected by ELRP on Netlogin VLAN when port is set
to mac-based VLAN.
EXOS-27632 ELRP process ends unexpectedly after receiving an invalid packet with ELRP
destination MAC address.
STP
EXOS-27701 When running the admin enable command, STP PDU is not sent out
immediately if the edge port is configured with edge safeguard and BPDU
restrict is enabled.
VLAN
EXOS-27553 Enabling netlogin on a port in the default VLAN does not move that port to
the netlogin configured VLAN.
EXOS-27576 After a reboot, the switch fails to load VLAN configuration on a port with
remote mirroring configured.